You are on page 1of 4

Technical 

support | E­mail: uktechnical@strongtie.com | Tel: +44 (0)1827 255 600

ESCRC ­ Countersunk head structural wood screw with
milling point, Electro­galvanized

Specifications
Manufacturer : Simpson Strong­Tie
Product: Escrc ­ countersunk head structural wood screw with milling point,
electro­galvanized 8,0x360
Predrilling is not required

Project data
Project number : ST­22­97­001
Project name : Renfort Toiture Ferme – Duras
Project part : Renfort Toiture Ferme – Duras
Wood Joint ID : Poincon
City : Duras

Responsible: Company : E­mail : santiago.vallejo@strec.fr


Tel: Adress : Zip Code : City:
Technical support | E­mail: uktechnical@strongtie.com | Tel: +44 (0)1827 255 600

ESCRC ­ Countersunk head structural wood screw Self­tapping screw for panel or timber to timber assembly or between panel or
with milling point, Electro­galvanized timber and steel members in accordance with ETA­13/0796 and EN 1995­1­1.

Corrosivity class: C2
Material: EN ISO 16120
Bits : TX40

Specifications Project data
Manufacturer : Simpson Strong­Tie Project number: ST­22­97­001
Product : Escrc ­ countersunk head structural wood screw with milling point, electro­ Project name : Renfort Toiture Ferme – Duras
galvanized 8,0x360 Project part: Renfort Toiture Ferme – Duras
Predrilling is not required Wood Joint ID : Poincon
City : Duras

Joint data Result
Joint type: Single shear Axial design load capacity per fastener Fax,Rd: 1,11 kN
Shear design load capacity per fastener Fv,Rd: kN
Material (A)
Type : Solid
Thickness : 150 mm
Total number of parallel fasteners : 2
Class/density : C14 (290kg/m3)

Total number of parallel fasteners per row parallel to the grain direction
Material (B) (Entered for wood part)
Type : Solid
Thickness : 1000 mm Row 1: 2 Row 3: Row 5:
Class/density : C14 (290 kg/m³) Row 2: Row 4: Row 6:

Material (C)
Type :
Thickness :
Class/density :

Corrosivity class: C2
Load duration : P

Total axial design load capacity Fax,ef,Rd:   2,07 kN
Total shear design load capacity Fv,ef,Rd:    kN

Applied axial design load Fax,Ed:   1.5 kN
Applied shear design load Fv,Ed:   
Verification of combined loads :   

Responsible: Company : E­mail : santiago.vallejo@strec.fr


Tel: Adress : Zip Code : City:
Technical support | E­mail: uktechnical@strongtie.com | Tel: +44 (0)1827 255 600

Mounting Requirements

General ­ screw General ­ nail
1. If the screw is to be mounted at an angle other than perpendicular to the [PDF_PAGE3_HEADING1_LABEL14]
material surface ­ make sure that screw axis is parallel to the load direction.

2. Loads do not apply for nailing into the end grain

3. Possible predrilling shall not be greater than 0,8d.

2. Some deviation from EC5 regarding predrilling may occur. This is based on
testing where predrilling sometimes has managed to be avoided.

Product specific
Under head milling nibs for optimized countersunk of the screw head. Friction
part and anti­friction coating reduces the insertion resistance. Lower torque
and faster installation when screwed in. Patented milling thread point ensures
low splitting e

General
1. Calculations are based on EN 1995­1­1:2004+A2014 section 8.1 to 8.7

2. Calculated loads are based on using dry wood

3. When inserting the fasteners, chapter 10 in EC5 shall be applied in order
for the result in the Solid Wood software to be applicable

4. Possible further controls may be necessary. Example of such controls may
be... 

­ Risk of splitting caused by tension forces (Section 8.1.4 of EC5)
­ Alternating internal forces (section 8.1.5 of EC5)
­ Shear plug failure
­ Quality control of installation
­ Capacity of steel plate when calculating Steel ­ Wood
­ ...etc.

Responsible: Company : E­mail : santiago.vallejo@strec.fr


Tel: Adress : Zip Code : City:
Technical support | E­mail: uktechnical@strongtie.com | Tel: +44 (0)1827 255 600

Edge­ and spacing distance
Centre distance along grain direction a1 : 56 mm
Centre distance across grain direction a2 : 40 mm

Material part A (and C) Material part B
Min. distance unloaded end a3,c (a1,CG)
80 mm 80 mm
Min. distance loaded end a3,t (a1,CG)
80 mm 80 mm
Min. distance unloaded edge a4,c (a2,CG)
32 mm 32 mm
Min. distance loaded edge a4,t (a2,CG)
32 mm 32 mm
Angle α1: 0 ° Angle α1: 0 °