Professional Documents
Culture Documents
Vascular
Screening Device
VaSera VS-2000
New
Patient Management
Partner
1 3
1 2
2 New design Smooth operation
which can with capacitive
be used on touch screen
a desk.
3 4
Height of shelf More functions
Maxi. distance
and monitor 200mm are available by
can be adjusted (0.66feet) adding modular
options.
❶Test Screens ❸Clear results screen
Provides a full display of the Comprehensively reported
examination flow and progress. results, yet simple to read. Fits in your office
❷Real-time CAVI check function
Fully automated test quality Total weight approx.
checks ensure reliable results at 14Kg(31lbs)
the time of testing.
Depth 487mm
(1.6feet)
Width 509mm
(1.67feet)
Greater Ease-of-Use with the On-Screen Guides
Even a first time user is able to perform an examination thanks to the on-screen guide.
Step by step instructions guide you from the patient registration up to the end of the examination.
Cautions
How to
before starting
attach the the
PCG examination
In simple mode, you can select either Pulse wave examina- If VS-2000 is not able to successfully
tion to evaluate arterial stiffness, or Blood Pressure exam- take a measurement, then a message
ination . ※ It is also possible to disable the on-screen guide will appear in the middle of the screen.
and switch to standard mode.
The examination conforms with the guidelines of AHA and ESH CAVI reflects the arterial stiffness from the heart to the ankle. Therefore it is a great indicator of Athero-
When building an average from multiple measurements, you can select the measurements of best quality. sclerosis. Also, a major advantage is its lesser dependence upon blood pressure changes at measurement
time.
Pulse Amplitude Graph CAVI average value of a healthy group by sex and age (every 5 years)
11
CAVI reference value
male:2,238
10 female:3,730
CAVI<8.0 Normal range
9 8.0≦CAVI<9.0 Borderline range
9.0≦CAVI Possible atherosclerosis
CAVI
7
Display of the vascular age
6 Using the reference graph of healthy subjects as
an indicator, it is possible to reflect the age of
5
20 25 30 35 40 45 50 55 60 65 70 over
the arteries.
24 29 34 39 44 49 54 59 64 69 (Age) Some versions of VaSera come with a vascular
Image of a mercury blood pressure meter Average value Japan Health Promotion Foundation age graph.
* Examination
send report
DMS
wired/wireless
VS-2000 ②Trolley ③BPU-100 ④BPU-100
+
①Accessories kit
(ASV-04H)
+ +
Limbs Blood Toe Blood
Pressure package Pressure package
PDF output report output
イチ
シン
ダ
フク
(ASV-05H) (ASV-06)
フクダ
シン
イチ
⑤EE-100
⑥Battery
+
Save to a share folder
BTE-001
ECG software package
(VSC-200E)
over the network
*CE only
It is possible to save the PDF file inside
a share folder over the network.
④BPU-100
+
Toe Blood
Speci fications
Pressure package
Display LCD display 1024 x 768 dots (LED back light) SD card slot SD Card Specification 2.0
(ASV-06)
PCG Frequency response L filter: 50 Hz(-6 dB/oct) LAN connector IEEE 802.3u, 100BASE-TX(cable within 50m)
PWV filter: 165 280Hz within -3dB USB connector USB2.0 Full Speed, 3 channel
NIBP Measuring range 0 300mmHg Safety standard IEC 60601-1: 1999
(BPU-100) Scale interval 1 mmHg Class of protection against
Class I, internally-powered equipment
①Cuff (Arm/Ankle), hoses Package and PCG ③Unit to measure 2 channels of PW and cuffs/hoses Package ④Unit to measure 2 channels of PW with connection Pressure accuracy 3mmHg electric shock
cable and toe cuffs Package ⑤12 Lead ECG amplificator, software license card, analysis reference CD Package In order to measure 12 lead ECG, you will need the Pressure detection Semiconductor pressure sensor Type of protection against NIBP input : Type CF(defibrillation-proof)
following: patient cable (CP-104J) and electrodes (TE-43, TEV-01RG, TE-01). (In simple mode, you will not be able to measure ABI.) In standard mode, you can
Zero balancing Automatic balancing electric shock PCG input : Type CF(defibrillation-proof)
measure left and right blood pressure and ABI values. Save or export the data with our SD card or USB memory stick. ⑥Runing on battery power→70minutes
Measuring method Oscillometric ECG input : Type CF(defibrillation-proof)
NIBP measuring range 20 280mmHg Power supply 100 240V AC 50/60Hz, 120 VA
Inflation method Automatic inflation by pump DC11.1V(Battery operation)