You are on page 1of 4

Sukajadi

-06.30111°,105.842249°
3, Sukajadi, Banten, Indonesia
Time zone: UTC+07, Asia/Jakarta [WIB]

 Report generated: 19 Aug 2022

SITE INFO

Map data Per year Map

Direct normal irradiation DNI 796.7 kWh/m 2

Global horizontal
GHI 1536.3 kWh/m 2
irradiation

Diffuse horizontal
DIF 933.0 kWh/m 2
irradiation

Global tilted irradiation at


GTI opta 1548.8 kWh/m 2
optimum angle

Optimum tilt of PV modules OPTA 9 /  0 °

Air temperature TEMP 27.2 °C

Terrain elevation ELE 11 m


500 m
3000 ft Leaflet | Satellite tiles © Esri

Horizon and sunpath


PVOUT map

300 km
300 mi Leaflet | PVOUT map © 2022 Solargis

© 2022 The World Bank Group Sukajadi 1/4


PV ELECTRICITY AND SOLAR RADIATION

PV system con guration



Pv system: Medium size comercial
Azimuth of PV panels: Default (0º)
Tilt of PV panels: 9º
Installed capacity: 38.4 kWp

Annual averages Average hourly pro les


Total photovoltaic power output and Global tilted irradiation Total photovoltaic power output [kWh]

46.290 1547.5
Jan Feb Mar Apr
25.2 25.2 25.2 25.2

MWh per year kWh/m2 per year 12.6 12.6 12.6 12.6

0 0 0 0
0 12 24 0 12 24 0 12 24 0 12 24
Monthly averages
Total photovoltaic power output May Jun Jul Aug
25.2 25.2 25.2 25.2
6
12.6 12.6 12.6 12.6

0 0 0 0
4 0 12 24 0 12 24 0 12 24 0 12 24
[MWh]

Sep Oct Nov Dec


25.2 25.2 25.2 25.2
2

12.6 12.6 12.6 12.6

0 0 0 0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0 12 24 0 12 24 0 12 24 0 12 24

UTC+07

Average hourly pro les


Total photovoltaic power output [kWh]

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0-1
1-2
2-3
3-4
4-5
5-6 0 0 0
6-7 1 1 1 1 1 1 1 1 1 3 3 2
7-8 4 4 5 7 7 6 6 7 8 9 8 5
8-9 8 9 10 12 13 12 12 14 15 14 12 9
9 - 10 12 13 15 16 17 17 17 18 19 18 15 12
10 - 11 15 16 18 18 19 19 19 20 21 18 16 14
11 - 12 16 17 18 18 18 18 19 19 20 17 16 15
12 - 13 17 18 18 18 17 17 18 18 19 16 15 15
13 - 14 15 16 16 16 15 15 16 17 17 14 13 13
14 - 15 12 13 13 12 11 11 13 13 13 10 9 10
15 - 16 9 9 9 7 7 7 8 9 8 6 6 7
16 - 17 5 5 4 3 3 3 4 4 4 3 3 3
17 - 18 1 2 1 1 0 0 1 1 1 0 1 1
18 - 19 0
19 - 20
20 - 21
21 - 22
22 - 23
23 - 24
Sum 116 123 130 129 127 127 133 140 146 128 115 108

© 2022 The World Bank Group Sukajadi 2/4


PV ELECTRICITY AND SOLAR RADIATION

Annual averages Average hourly pro les


Direct normal irradiation Direct normal irradiation [Wh/m2]

807.5
Jan Feb Mar Apr
500 500 500 500

kWh/m2 per year 250 250 250 250

0 0 0 0
0 12 24 0 12 24 0 12 24 0 12 24
Monthly averages
Direct normal irradiation May Jun Jul Aug
500 500 500 500
100
250 250 250 250

75
0 0 0 0
[kWh/m 2]

0 12 24 0 12 24 0 12 24 0 12 24

50 Sep Oct Nov Dec


500 500 500 500

25
250 250 250 250

0 0 0 0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0 12 24 0 12 24 0 12 24 0 12 24

UTC+07

Average hourly pro les


Direct normal irradiation [Wh/m2]

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0-1
1-2
2-3
3-4
4-5
5-6 2
6-7 35 17 37 48 57 43 32 34 40 74 93 55
7-8 106 110 170 207 220 213 197 219 243 200 171 112
8-9 152 168 227 279 319 312 316 345 346 280 226 149
9 - 10 192 213 263 321 371 378 386 401 395 296 241 174
10 - 11 226 256 294 310 344 374 375 362 362 256 216 185
11 - 12 258 263 295 288 283 318 325 304 304 205 195 201
12 - 13 279 263 290 284 255 279 288 290 288 182 182 201
13 - 14 260 254 273 248 233 245 273 264 264 165 161 173
14 - 15 195 189 201 182 158 183 206 193 190 96 114 127
15 - 16 140 128 133 112 97 126 139 130 119 61 67 86
16 - 17 82 79 80 64 52 71 81 76 60 37 37 50
17 - 18 35 34 32 21 8 10 18 16 12 6 10 14
18 - 19
19 - 20
20 - 21
21 - 22
22 - 23
23 - 24
Sum 1960 1974 2293 2365 2396 2552 2636 2636 2622 1860 1716 1527

© 2022 The World Bank Group Sukajadi 3/4


GLOSSARY

Acronym Full name Unit Type of use


DIF Diffuse horizontal irradiation kWh/m², MJ/m² Average yearly, monthly or daily sum of diffuse horizontal irradiation (©
2021 Solargis)
DNI Direct normal irradiation kWh/m², MJ/m² Average yearly, monthly or daily sum of direct normal irradiation (© 2021
Solargis)
ELE Terrain elevation m, ft Elevation of terrain surface above/below sea level, processed and
integrated from SRTM-3 data and related data products (SRTM v4.1 ©
2004 - 2021, CGIAR-CSI)
GHI Global horizontal irradiation kWh/m², MJ/m² Average annual, monthly or daily sum of global horizontal irradiation (©
2021 Solargis)
GTI Global tilted irradiation kWh/m², MJ/m² Average annual, monthly or daily sum of global tilted irradiation (© 2021
Solargis)
GTI_opta Global tilted irradiation at optimum angle kWh/m², MJ/m² Average annual, monthly or daily sum of global tilted irradiation for PV
modules x-mounted at optimum angle (© 2021 Solargis)
OPTA Optimum tilt of PV modules ° Optimum tilt of x-mounted PV modules facing towards Equator set for
maximizing GTI input (© 2021 Solargis)
PVOUT_total Total photovoltaic power output kWh, MWh, GWh Yearly and monthly average values of photovoltaic electricity (AC)
delivered by the total installed capacity of a PV system (© 2021 Solargis)
PVOUT_speci c Speci c photovoltaic power output kWh/kWp Yearly and monthly average values of photovoltaic electricity (AC)
delivered by a PV system and normalized to 1 kWp of installed capacity
(© 2021 Solargis)
TEMP Air temperature °C, °F Average yearly, monthly and daily air temperature at 2 m above ground.
Calculated from outputs of ERA5 model (© 2021 ECMWF, post-processed
by Solargis)

ABOUT

This pdf report (the “Work”) is automatically generated from the Global Solar Atlas online app (https://globalsolaratlas.info/), prepared by
Solargis under contract to The World Bank, based on a solar resource database that Solargis owns and maintains. It provides the estimated
solar resource, air temperature data and potential solar power output for the selected location and input parameters of a photovoltaic (PV)
power system.

Copyright © 2021 The World Bank


1818 H Street NW, Washington DC 20433, USA

The World Bank, comprising the International Bank for Reconstruction and Development (IBRD) and the International Development
Association (IDA), is the commissioning agent and copyright holder for this Work, acting on behalf of The World Bank Group. The Work is
licensed by The World Bank under a Creative Commons Attribution license (CC BY 4.0 IGO) with a mandatory and binding addition (please
refer to the GSA website for full terms and conditions of use https://globalsolaratlas.info/support/terms-of-use).

The World Bank Group disclaims all warranties of any kind related to the provision of the Work.

The Work is made available solely for general information purposes. Neither the World Bank, Solargis nor any of its partners and a liates
hold the responsibility for the accuracy and/or completeness of the data and shall not be liable for any errors, or omissions. It is strongly
advised that the Work be limited to use in informing policy discussions on the subject, and/or in creating services that better educate relevant
persons on the viability of solar development in areas of interest. As such, neither the World Bank nor any of its partners on the Global Solar
Atlas project will be liable for any damages relating to the use of the Work for nancial commitments or any similar use cases. Solargis has
done its utmost to make an assessment of solar climate conditions based on the best available data, software, and knowledge.

Sources: Solar database and PV software © 2021 Solargis

© 2022 The World Bank Group Sukajadi 4/4

You might also like