7. SURFACE PREPARATION:
The following types of surface preparation grades (ref. Swedish Standard
SIS 05 5900) are the minimum required for steel surfaces.
Surface Preparation
Conditions
Standards
Type I Initial painting and maintenance painting SA 2-1/2
Where blasting is allowed
5460 Type II ST 3
4260
8. Painting Work
(a) All steelwork shall be primed and painted to protect against corrosion
1200 3060 1200
(b) Coating system shall be as specified below:
Primer coat shall consist of one coat of ICI Dulux Fast Drying
Grey Green Zinc Phosphate Primer A500-13562
Top coat shall consist of two coats of ICI Dulux Single Packed Corrosion
Resistant DTM Coating A363-Line.
(c) No painting is to be carried out until S.O's approval has been obtained.
Each coat shall be inspected and approved before subsequent coat is being
1200
applied.
(d) Any irregularity in painting shall be smoothened by grinding to level with
parent material.
9. The contractor shall arrange and carry out testing of weld according to
14 15 16 17 18 19 20 21 22 23 24 25 26 Specification for selected weld joint test piece as directed by S.O.
450
13 12 11 10 9 8 7 6 5 4 3 2 1
1200
UP
PLAN
F1 900 / 900 (d = 300)
4T16
5460
900
4T16
4260
4T16
1200 3060 1200
3315 945
'C'
300 50
900
255
150 EXISTING BM
1950
300
'C' CHANNEL
4T16
50
4.5mm THK. CHEQUER PLATE
WELDED TO
180 x 75 x 20 x20.3 kg/m 'C' CHANNEL
AT BOTH SIDES
2 NOS.
75 x 75 x 4.0mm SHS 255
1950
150
EXISTING
GROUND
'B' 'A'
SECTION
4.5mm THK. CHEQUER PLATE
WELDED TO
180 x 75 x 20 x20.3 kg/m C CHANNEL
AT BOTH SIDES
2 NOS. 75 x 75 x 4.0mm SHS
WELED TO M.S. PLATE 275x415x6mm Thk.
MS Plate
180 x 75 x 20 x20.3 kg/m C CHANNEL PROPOSED PAD
WELDED TO M.S. PLATE FOOTING
125
DOWN BOLT WITH MINIMUM 125mm
200 x 445 x 5mm EMBEDDED DEPTH
PROPOSED Thk.
MS Plate
PAD FOOTING
200
4 NOS. M12 HOLDING
125
DOWN BOLT WITH MINIMUM 125mm
EMBEDDED DEPTH
200
200 x 200x 5mm
Thk.
445 MS Plate