Programming steps of G2B radio remote controls.

SPEED LEVELS
Scanreco G2B remote control can have up to 3 SETs of speed.

IMPORTANT: While the SET1 is usually used for standard operation, the other two sets (SET2 and
SET3) can be used in a different way, depending on the configuration of the machine.

For example:
- for remote controls with only two speed sets, the SET2 is used for the PLATFORM mode.
- for some remote controls with three speed sets, the SET3 is used for the PLATFORM mode while
the SET2 is used for the crane mode at reduced speed.
- for other remote controls with three speed sets, the SET2 is used for the PLATFORM mode while
the SET3 is used for the crane mode at reduced speed.

Please always refer to the specific datasheet of the system that you are programming, to know which
programming step you need to modify.
In case of doubt, please change the value of only one parameter, making sure to note the previous value, in
order to restore it if necessary, and verify, leaving the programming mode, that the modification is actually
what was required.

The following table lists the parameters that can be changed:

Step Description Acoustic signal


( = long beep / • = short beep)
1 Direction of the movement •
2 SET1 START (minimum speed) ••
3 SET1 MAX (maximum speed) ••• HARE
4 SET1 MICRO (reduced max. speed) •••• TURTLE
5 Acceleration ramps •
6 Deceleration ramps ••
7 SET2 START (minimum speed) •••
8 SET2 MAX (maximum speed) •••• HARE
9 SET2 MICRO (reduced max. speed)  • TURTLE
10 Acceleration ramps  ••
11 Deceleration ramps  •••
12 SET3 START (minimum speed)  ••••
13 SET3 MAX (maximum speed)    • HARE
14 SET3 MICRO (reduced max. speed)    • • TURTLE
15 Delayed bypass switch-off (DV)   •••

NOTE: SET3 RAMPS are only modifiable with WINSCI program.

ATTENTION: when you are in programming mode, the remote control works in the speed
SET that you are programming (identified by the programming step you are in), regardless of
the state of the speed select inputs, used during standard operation.

Please pay particular attention during programming operations.

NOTE: To protect the parameters from unauthorized changes, is possible to disable the
programming of some steps, leaving enabled only the ability to display the value.