OF HEAD
METERS
FEET
110
IMPELLER DIAMETER
250
100 50
30 245
HE
AD
240 CA
90 PA
C ITY
235 5 hp
3 hp
80 230 40
225
220 7½ hp
215
70
210
20 205
200
60 30
50
40 20
10
30
20 10
NPSH REQUIRED
NPSH IN FEET
10
0 0 0
M3/HR. 0 5 10 15 20 25 30 35
CAPACITY
Table of Contents
Introduction.........................................................................................................................2
Pump basics..........................................................................................................................4
Selecting a pump..................................................................................................................5
Conversion factors..............................................................................................................10
Pharmaceutical options......................................................................................................13
Pump Performance Curves: 1750 RPM Pump Performance Curves: 3500 RPM
FP/FPX/FPR Composites.............. 14 FP/FPX/FPR Composite................ 34
701 ................................................ 16 702 ................................................ 36
711 ................................................ 17 712 ................................................ 37
721 ................................................ 18 722 ................................................ 38
3521............................................... 19 3522............................................... 39
731 ................................................ 20 732 ................................................ 40
3531............................................... 21 1732............................................... 41
741 ................................................ 22 3532............................................... 42
1741............................................... 23 742 (2)........................................... 43
3541............................................... 24 1742 (2)......................................... 45
751 ................................................ 25 3542............................................... 47
3451............................................... 26 752 ................................................ 48
3551............................................... 27 3452............................................... 49
1051............................................... 28 3552............................................... 50
1151............................................... 29 3552-4”.......................................... 51
1161 (2)......................................... 30 3642 .............................................. 52
4001............................................... 32 3652 .............................................. 53
4001X............................................. 33
Dimensional Drawings
FP Single Flange..........................................................................................................54
FP Double Flange (2)...................................................................................................55
FPX Single Flange........................................................................................................57
FPX Double Flange......................................................................................................58
FPR Single Flange........................................................................................................59
FPR Double Flange (2).................................................................................................60
1
Fristam Pride
Fristam is a global manufacturer of sanitary centrifugal and positive displacement pumps,
mixers and blenders respected for unmatched performance, reliability, and technical superiority.
Fristam manufactured its first pump in 1931. Today, Fristam equipment is used by many of the
world’s top dairy, beverage, brewing, bio-pharmaceutical, and food processing companies.
Quality Control
Fristam Pumps USA designs, manufactures, and assembles its pumps
in the United States. Each component is carefully checked from raw
material through final assembly.
The result of this effort is a pump worthy of the valuable product your
company produces. To achieve the highest level of quality, Fristam offers
the most comprehensive testing and documentation packages in the
sanitary pump industry.
2
Experience and Expertise
Over the past 100 years, Fristam has built its reputation with experience, attention
to detail, and a willingness to adapt to changing needs. Fristam’s strong applications
engineering capabilities make it the most reliable source for straight, smart answers to
process needs.
Dedicated Support
Fristam’s dedication and quality service do not end with your initial
purchase. An international network of manufacturing facilities, sales
offices and distribution supports Fristam’s commitment to customer
satisfaction.
3
Pump Basics: Background Information
Pump Series – FP, FPX, or FPR
The FP, FPX, and FPR Series pumps are manufactured of
316L stainless steel and have the same pump head. The FP
incorporates a heavy-duty pedestal flange between the motor
22
2
72
35
and pump head. The FPX is a motor mounted pump used
PRESSURE
for standard duties. The FPR has a front-loading seal for
easy changeout and may be used in place of either the FP
or FPX. Double seals are only available in the FP and FPR.
The FP is used for vacuum withdrawal, high temperature,
high viscosity, aseptic processes and other demanding
FPR 3522
FPR 722
applications.
5
Example Seal Selection: Single or Double
Using our previous example of 50 gallons per minute and 135 Many applications require only single seals. Double seals
feet of head, we can determine from Figure 3 that the impeller are recommended for applications involving:
diameter should be 145 millimeters (5.7 inches). The motor • Abrasive products
required is 5 horsepower. • Sticky products
• Vacuum >14” Hg
Checking NPSH (Net Positive Suction Head) • Temperature regulation
To assure there is sufficient product pressure at the inlet of
the pump the suction conditions need to be checked. The Seal Selection: Materials
NPSH required can be determined by finding the point on Recommended seal material configurations:
the individual pump curve where the vertical line from the • Simple transfer applications: FR-N-(K)*
desired flow rate intersects the NPSH curve. From this point, • Sticky applications: FR-C-(N)*
a horizontal line to the right will intersect the NPSH scale at • Pharmaceutical applications, chlorine, brine: C-C-(N)*
the net positive suction head required.* * rotating seal, stationary seal, (flush/double seal)
The procedure for determining the NPSH available is N = Carbon
described in the “How To Calculate Required Pressure” section C = Silicon Carbide
of this book. When the NPSH available is determined, it must FR = Chrome Oxide Coated Stainless Steel
meet or exceed the NPSH required for the pump to function K = Ceramic
properly. If the NPSH available is
insufficient, a change to the inlet Figure 3
OF HEAD
OF HEAD
METERS
Example 40 140
110
Elastomers 20
Viton is the standard seal 60
NPSH REQUIRED
0 0 0
GPM 0 30 60 90 120 150
M3/HR. 0 5 10 15 20 25 30
CAPACITY
*Please note that the NPSH values shown are for full size impellers. Smaller impellers may require somewhat greater NPSH.
6
Pump Inquiry Application Data Sheet
The following information is required to properly process an inquiry:
Requested by______________________________________________________ Date___________________________________
Customer________________________________________________________________________________________________
Address__________________________________________________________________________________________________
Telephone___________________________________ Fax__________________ Email___________________________________
Description of product to be pumped__________________________________________________________________________
________________________________________________________________________________________________________
Temperature___________ Specific Gravity______________________________ or Density_________________________ lb./gal.
Viscosity____________________________________ Centipoise (CPS) or other
Desired Flow Rate____________________________ GPM or lb./hr.
*Discharge Head_____________________________ ft. or PSI
Suction Conditions
Is the pump withdrawing from a vacuum?_________ Yes__________No
If so, how much?_____in. Hg.
Is the product level on the inlet side of the pump above or below the center line of the pump inlet?
Above_________________ Below________________ By how much?_________ in. or ft.
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
No. of size of valves in suction piping:
_____________________ No.___________________ Size (in.)
_____________________ No.___________________ Size (in.)
Other equipment in the suction piping________________________________________________________________________
________________________________________________________________________________________________________
*If you do not know the desired discharge head, please provide the following:
Discharge Conditions
Is the final destination of the pump above or below the center line of the pump inlet?
Above_________________ Below________________ By how much?_________ in. or ft.
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
No. and size of valves in discharge piping:
_____________________ No.___________________ size (in.)
_____________________ No.___________________ size (in.)
_____________________ No.___________________ size (in.)
Other equipment and the drop or pressure requirement (PSI) in the discharge piping__________________________________
________________________________________________________________________________________________________
7
How To Calculate Required Pressure
Example:
Find the head under these conditions: Pump is drawing
299.2 ft.
from an open tank to discharge through a heat exchanger
into an open tank that is 20 ft. above the pump. The supply
is 8 ft. above the pump. 50 GPM flow is required. Outlet Open Tank
1 1/2" Pipe Water 62
8
Specific Gravity and Detailed information is available on viscosity correction factors. Contact
Fristam Pumps for details. The following viscosities may vary, depending
Viscosity for Various Liquids upon products, formulas, and processes used by processors.
Product SP. Visc. Temp Condition Product SP. Visc. Temp Condition
Gr. (cps) °F Gr. (cps) °F
9
Conversion Factors
Length Pressure (continued)
Meters x 3.281 = Feet Atmosphere x 33.9 = Feet of Water
Centimeters x 0.394 = Inches PSI x 2.31 = Feet of Water
Millimeters x 0.0394 = Inches Inches of Hg. x 1.13 = Feet of Water
Mass Flow
Kilograms x 2.2 = Lbs. Lbs. Of Water/Hour x 0.002 = GPM
Gallons Of Water x 8.34 = Lbs. Lbs. Of Fluid/Hour x 0.002 = GPM
Cubic Feet of Water x 62.4 = Lbs. Specific Gravity
Pounds x 0.454 = Kilograms Cu. Meter/Hour x 4.4 = GPM
Kg. Of Water/Minute x 0.264 = GPM
Volume Liters/Minute x 0.264 = GPM
Liter x 0.264 = Gallon GPM x 3.785 = Liters/Minute
Cubic Feet x 7.48 = Gallon
Lbs. Of Water x 0.119 = Gallon Power
Imperial Gallon Liquid HP = GPM x Head ft. x Specific Gravity
(British) x 1.2 = Gallon (U.S.) 3960
U.S. Gallon x 3.785 = Liter
BHP = GPM x Head ft. x Specific Gravity
Pressure 3960 x Pump Efficiency
Feet of Water x 0.433 = PSI
Inches of Hg. x 0.491 = PSI Viscosity
Atmosphere x 14.7 = PSI Centipoise = Centistokes
Meters of Water x 1.42 = PSI Specific Gravity
Kilograms/sq.
Centimeter x 14.22 = PSI Centistokes x 4.64 = SSU (Approx.)
Bar x 14.7 = PSI
Temperature
(1.8 X °C) + 32 = °F
.555 (°F – 32°) = °C
Degrees Kelvin – 273.2 = Degrees Centigrade
40
30
PRESSURE
(psia)
20
10
0
0 32 50 100 150 200 250 300
TEMPERATURE (F)
10
Loss of Head Due to Friction in Feet per Foot of Stainless Steel Tubing
and in Feet for Sanitary Fittings
Notes:
1. Flow Elbows—R/D = 1.5 A
2. Flow Through Tees—Flow A
to B Port C capped off.
C B
3. Test Medium—Water at 70°F
4. 16 gauge tubing was used for the measurements when the outer diameter (O.D.)
was between 1" - 3" and 14 gauge tubing was used with the 4" O.D. measurement.
*Calculated data for estimating purposes only. Consult your tubing manufacturer with specific questions.
11
Fristam Centrifugal Options
SEAL MATERIALS HARDWARE OPTIONS
1st – Rotating Stainless steel flange
2nd – Stationary Aseptic
3rd – Flush (Double) Seal [FP and FPR only] Jacketed housing
Casing drain
Single Seal Bearing block mounted
FR-N – Chrome oxide SS vs. carbon Adjustable base with legs
C-N – Silicon carbide vs. carbon Impeller inducer
C-C – Silicon carbide vs. silicon carbide
FR-C – Chrome oxide SS vs. silicon carbide ELASTOMERS
Viton
Double Seal [FP and FPR only] EPDM
FR-N-N – Chrome oxide SS vs. carbon vs. carbon Buna cover gasket
C-N-N – Silicon carbide vs. carbon vs. carbon Perfluoroelastomer
C-C-N – Silicon carbide vs. silicon carbide vs. carbon USP Class VI Viton and EPDM
FR-C-N – Chrome oxide SS vs. silicon carbide vs. carbon
12
Pharmaceutical Options
All standard stainless steel components are 316L. Special castings are available
in low-ferrite stainless steel or high-performance alloys such as Hastelloy® and
AL-6XN®. Class VI elastomers are standard for pharmaceutical applications.
Casing drain and mounting options provide complete drainability critical for
long-term system cleanliness. Pumps can be easily configured for steam-in-
place sterilization, with no external cooling devices required.
Fristam pioneered a pressurized double seal flush system that ensures product
sterility and saves valuable product by maintaining positive pressure in the
critical seal area. The internal seal design provides extra cooling and lubrication
on the front seal face to significantly extend seal life and provide for more
system uptime.
Numerous seal and piping configurations, including single seal piping, are
available to meet your processing requirements.
Comprehensive
Documentation Options
Certified Drawings
Mill Certification
Physical Certifications
Material Verification
Certificate of Conformance
Certified Finish
Passivation Certificate
Certified Welding
Hydrostatic Test
Short Run Test
Performance Test
NPSH Test
Witness Test
Vibration Test
Noise Test
13
FP/FPX/FPR Performance Curves
Models: 1750 RPM(Composite “A”)
Maximum Flow: 400 GPM
OF HEAD
METERS
FT. OF
HEAD
125
30 100
75
751
20 1741
50
741
10 3451
25 3541
731
721
711 3531
3521
0 701
0
0 50 100 150 200 250 300 350 400 GPM
0 20 40 60 80 M3/HR
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
14
FP/FPX/FPR Performance Curves
Models: 1750 RPM(Composite “B”)
Maximum Flow: 2000 GPM
OF HEAD
METERS
FT. OF
HEAD
60 200
175
50
150
4001-X
40
125
1161
4001
30 100
1151
75
20
50
10
25 3551
1051
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 GPM
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
15
FP/FPX/FPR Performance Curves
Model: 701 (1750 RPM, Inlet 1.5”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
20
6
18
5 IMPELLER DIAMETE
16 R
100
95
14
4 90
12 85
80
3 10
¹⁄3 hp
75
¼ hp
8
HE
AD
CA
PA
2
C
ITY
4
1
0 0 0
GPM 0 4 8 12 16 20 24 28 32 36 40
M3/HR. 0 1 2 3 4 5 6 7 8
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
16
FP/FPX/FPR Performance Curves
Model: 711 (1750 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
30
IMPELLER DIAME
130 TER
125
8
120 ½ hp
25
115
¼ hp
110
HE
AD
105
20
CA
6
PA
100
CIT
Y
¾ hp
15
10 10
5 5
NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 10 20 30 40 50 60
M3/HR. 0 2 4 6 8 10 12
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
17
FP/FPX/FPR Performance Curves
Model: 721 (1750 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
40
12
IMPELLER D
145 IAMETER
35 140
10 135
¾ hp
130
30
125
½ hp
8
HE
120 1 hp
AD
25
CA
PA
115
CI
TY
110
6 20
15
4
10
2
5 5
NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 10 20 30 40 50 60 70 80
M3/HR. 0 3 6 9 12 15 18
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
18
FP/FPX/FPR Performance Curves
Model: 3521 (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
40
12
IMPELLER DIAMETER
145
35
140
10
1½ hp
30 135
HE
AD
130
8
CA
1 hp
PA
25
CI
TY
125
¾ hp
120
6 20
½ hp
115
15
4
10
2
5 10
NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 25 50 75 100 125 150 175 200
M3/HR. 0 5 10 15 20 25 30 35 40 45
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
19
FP/FPX/FPR Performance Curves
Model: 731 (1750 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
50
15
IMPELLE
175 R DIAM
ETER
170
165 ¾ hp
160
½ hp
155
40
12 150
1 hp
30
HE
9
AD
CA
PA
1½ hp
CI
TY
6 20
3 10 10
5 NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 20 40 60 80 100
M3/HR. 0 5 10 15 20
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
20
FP/FPX/FPR Performance Curves
Model: 3531 (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
55
175 IMPELLER
DIAME
TER
170
15 50
165
45 3 hp
160
155
2 hp
40
150
145 1½ hp
35
HE
AD
10 140
CA
PA
135
CIT
30 1 hp
Y
130
25
20
5
15
10 20
NPSH IN FEET
5 10
NPSH REQUIRED
0 0 0
GPM 0 25 50 75 100 125 150 175 200 225 250 275
M3/HR. 0 10 20 30 40 50 60
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
21
FP/FPX/FPR Performance Curves
Model: 741 (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
70
IMPELLER DIAMETE
205 R
20 200
1½ hp 2 hp
195
190
60 1 hp
185
180
175
170
165
50
15
HE
AD
3 hp
CA
PA
CIT
Y
40
10
30
20
10 10
NPSH IN FEET
5
NPSH REQUIRED
0 0 0
GPM 0 20 40 60 80 100 120 140
M3/HR. 0 5 10 15 20 25 30
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
22
FP/FPX/FPR Performance Curves
Model: 1741 (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
90
25
80 IMPELLER DIAMETER
205
200
HEA
195 DC
70 2 hp APA
190 CIT
Y
20 185 5 hp
1½ hp 3 hp
180
60 175
170
165
15 50
40
10
30
20 10
5
10 5 NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 20 40 60 80 100 120 140 160 180
M3/HR. 0 10 15 20 25 30 35 40
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
23
FP/FPX/FPR Performance Curves
Model: 3541 (1750 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD
OF HEAD
METERS
FEET
80
IMPELLER DIAMETER
70 205
20 200
195
60
190
185
180 3 hp
50
HE
15 175 5 hp
AD
CA
170 7 hp
PA
CI
165
TY
160
40 155
150
10
30
20 20
5
10 10
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
24
FPR Performance Curves
Model: 751 (1750 RPM, Inlet 3”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
110
IMPELLER DIAMETER
250
100 50
30 245
HE
AD
240 CA
90 PA
C ITY
235 5 hp
3 hp
80 230 40
225
220 7½ hp
215
70
210
20 205
200
60 30
50
40 20
10
30
20 10
NPSH REQUIRED
10 NPSH IN FEET
0 0 0
M3/HR. 0 5 10 15 20 25 30 35
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
25
FP/FPX/FPR Performance Curves
Model: 3451 (1750 RPM, Inlet 3”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
120
35
100
30
IMPELLER DIAMET
250 ER
245
240
25 235 5 hp
80
230
225
220 HE
AD
3 hp CA
20 215 PA
CI
210 TY
60 2 hp
205 7½ hp
200
15 195
40
10
20 20
5
NPSH IN FEET
10
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300
M3/HR. 0 10 20 30 40 50 60
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
26
FP/FPX/FPR Performance Curves
Model: 3551 (1750 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD
OF HEAD
METERS
FEET
130
120
35
110 IMPELLER DIAMET
250 ER
245
100 240
30
235
230
90 10 hp 15 hp
225
220 7½ hp HE
25 5 hp A
80 215
D
CA
210
PA
CIT
205
70
Y
200
20 195
60
15 50
40
10
30
20 40
5
NPSH IN FEET
10 20
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
27
FP/FPX/FPR Performance Curves
Model: 1051 (1750 RPM, Inlet 4”, Outlet 4”)
OF HEAD
OF HEAD
METERS
FEET
120
35
280 IMPELLE
R DIAM
ETER
275
100 270
30
265
260
255
25 80 250
245
20 hp
240
20 15 hp
HE
60 10 hp AD
CA
PA
7½ hp CIT
Y
15
40
10
20 20
5
NPSH IN FEET
10
NPSH REQUIRED
0 0 0
GPM 0 150 300 450 600 750 900
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
28
FP/FPX Performance Curves
Model: 1151 (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
OF HEAD
OF HEAD
METERS
FEET
200
60
175
50
150
R DIAMETER
IMPELLE
40
280
125
275
270
HEA
DC
APA
265 10 HP 15 HP 20 HP CIT
260 25 HP Y
255 30 HP
30 100 250
245
240
75
20
50 20
10
25 10
NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
29
FP/FPX Performance Curves
Model: 1161 (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
OF HEAD
OF HEAD
METERS
FEET
200
60
320
175
315
50 310
305
300
150 295
290
285 IMPELLER DIAMETER
40
280
125 15 HP
275 HEAD
20 HP CAP
270 ACIT
25 HP Y
265 10 HP
260
255
30 100 250 30 HP
245
240
75
20
50 20
10
25 10
NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
30
FPR Performance Curves
Model: 1161 (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
OF HEAD
OF HEAD
METERS
FEET
200
60
IMPELLER DIAMETER
320
175
315
50 310
HEA
305 D CAP
300 ACI
TY
150 295 25 HP 50 HP
290
20 HP 40 HP
285
40
280
125 15 HP 30 HP
275
270
265 10 HP
260
255
30 100 250
245
240
75
20
50 20
10
25 10
NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
31
FPR Performance Curves
Model: 4001 (1750 RPM, Inlet 6”, Outlet 4”)
OF HEAD
OF HEAD
METERS
FEET
60 200
IMPELLER DIAMETER
180 360
HEA
350 D CA
PAC
50 ITY
160 340
330
140 75 hp
320
40
50 hp 60 hp
310 30 hp 40 hp
120
300
290
30 100
280
80
20
60
40 20
10
UIRED
NPSH REQ
NPSH IN FEET
20 10
0 0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800 2000
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
32
FPR Performance Curves
Model: 4001-X (1750 RPM, Inlet 6”, Outlet 4”)
OF HEAD
OF HEAD
METERS
FEET
60 200
50 hp
75 hp
180
50
160
100
hp
140
40
120
30 100
80
20
60
40 20
10
UIRED
NPSH REQ
NPSH IN FEET
20 10
0 0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800 2000
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
33
FP/FPX/FPR Performance Curves
Models: 3500 RPM(Composite “A”)
Maximum Flow: 800 GPM
OF HEAD
METERS
FT. OF
HEAD
450
420
120 390
360
100 330
3552
752
300
80 270
240
210
60 1742
180
742
150
40 1732 3532 3452
120
732
722
90
3542
20 3522
60
712
30
702
0 0
0 50 100 150 200 300 400 500 500 700 800 GPM
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
34
FP/FPX/FPR Performance Curves
Models: 3500 RPM(Composite “B”)
Maximum Flow: 1700 GPM
OF HEAD
METERS
FT. OF
HEAD
500
140
450
120 400
350
100
3552 4”
300
3652
80
250
60 200
3642
150
40
100
20
50
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 GPM
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
35
FP/FPX/FPR Performance Curves
Model: 702 (3500 RPM, Inlet 1.5”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
90
25
75
20 IMPELLER
100 DIAMETE
R
60
95
90
15
85
45
¾ hp 1½ hp
½ hp 1 hp HE
80 AD
C
AP
AC
10 75
IT
Y
30
5
15
6 NPSH IN FEET
4
NPSH REQUIRED
2
0 0 0
GPM 0 10 20 30 40 50 60
M3/HR. 0 2 4 6 8 10 12
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
36
FP/FPX/FPR Performance Curves
Model: 712 (3500 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
120
35
130mm IMPELLER
130 DIAMETER
5 1/4"
100
30 125 3 hp
120
2 hp
25 115
80
110
HE
AD
20
CA
PA
60
CIT
5 hp
Y
15
40
10
20 10
5
NPSH IN FEET
IRED
NPSH REQU
0 0 0
GPM 0 20 40 60 80 100 120
M3/HR. 0 5 10 15 20 25
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
37
FP/FPX/FPR Performance Curves
Model: 722 (3500 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD
OF HEAD
METERS
FEET
150
45
IMPELLER DIAMETER
145
40 140
120 135
35 5 hp HE
A
130
D
CA
PA
CIT
125 3 hp
Y
30 2 hp 7½ hp
120
90
25 115
110
20
60
15
10
30
10
5 NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 30 60 90 120 150
M3/HR. 0 5 10 15 20 25 30
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
38
FP/FPX/FPR Performance Curves
Model: 3522 (3500 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
160
IMPELLER DIAME
145 TER
45
140
140
40 10 hp
135
120
7½ hp
35 130
HE
AD
CA
PA
100 125
30
CIT
5 hp
Y
120
25 15 hp
80
115 3 hp
20
60
15
40
10
20 40
5 NPSH IN FEET
20
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400
M3/HR. 0 10 20 30 40 50 60 70 80 90
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
39
FP/FPX Performance Curves
Model: 732 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
OF HEAD
OF HEAD
METERS
FEET
200
60
165 IMPELLER
DIAMETE
175 R
160
50
155
30 100
125
120
3 hp
75
20
50 10
10
25 5
NPSH IN FEET
QUIR ED
NPSH RE
0 0 0
GPM 0 25 50 75 100 125 150 175 200
M3/HR. 0 5 10 15 20 25 30 35 40 45
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
40
FP/FPX Performance Curves
Model: 1732 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
OF HEAD
OF HEAD
METERS
FEET
225
R DIAMETER
200 IMPELLE
60 165
160 7½ hp
175
155 HE
10 hp 15 hp AD
50 CA
PA
150
CIT
Y
150
20 hp
145
40 140
125
30 100
75
20
30
50
10
15
25 NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 75 150 225 325 375
M3/HR. 0 10 20 30 40 50 60 70 80
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
41
FP/FPX/FPR Performance Curves
Model: 3532 (3500 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
225
175
IMPELLER DIAMETER
170
200
60
165
HE
160 AD
175 CA
PA
CI
155 TY
50
150 20 hp 25 hp
150
145
40 140 15 hp
125
135 7½ hp 30 hp
5 hp
130 10 hp
30 100
75
20
50 50
10
25 25 NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450
M3/HR. 0 20 40 60 80 100
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
42
FP/FPX Performance Curves
Model: 742 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
OF HEAD
OF HEAD
METERS
FEET
300
80 205
IMPELLER DIAM
ETER
250 200
195
HEA
D CA
190 PAC
ITY
185 7½ hp
180 10 hp 15 hp
175
60 200
170
20 hp
150
40
100
20
50 10
NPSH IN FEET
IRED
NPSH REQU
0 0 0
M3/HR. 0 10 20 30 40
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
43
FPR Performance Curves
Model: 742 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
OF HEAD
OF HEAD
METERS
FEET
300
80 205
IMPELLER DIAM
ETER
250 200
195
HEA
D CA
190 PAC
ITY
185
180 15 hp
175 10 hp
60 200
170
20 hp
165
7½hp
160
155
150 150
5 hp
145
40
140
135
130 3 hp
100
125
120
20
50 10
NPSH IN FEET
IRED
NPSH REQU
0 0 0
M3/HR. 0 10 20 30 40
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
44
FP/FPX Performance Curves
Model: 1742 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
OF HEAD
OF HEAD
METERS
FEET
350
100
IMPELLER DIAMETER
205
300
200
195
80 190
250 185 25 hp HE
15 hp 20 hp 30 hp AD
CA
180 40 hp PA
10 hp CI
TY
175
200 170
60
50 hp
150
40
100
20
50 20
NPSH IN FEET
10
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500
M3/HR. 0 20 40 60 80 100
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
45
FPR Performance Curves
Model: 1742 (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
OF HEAD
OF HEAD
METERS
FEET
350
100
IMPELLER DIAMETER
205
300
200
195
80 190
250 185 25 hp HE
30 hp AD
CA
180 40 hp PA
20 hp CI
TY
175
15 hp
200 170
60
165 10 hp
160
50 hp
155
150 7½ hp
150
145
40 140
100
20
50 20
NPSH IN FEET
10
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500
M3/HR. 0 20 40 60 80 100
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
46
FP/FPX/FPR Performance Curves
Model: 3542 (3500 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD
OF HEAD
METERS
FEET
90 300
IMPELLER DIAMETER
205
80 200
250
195 30 hp
70 190
25 hp
185 20 hp
HE
AD
180
200
CA
60
PA
175
CI
TY
170 15 hp
40 hp
165 50 hp
50
160 10 hp
150 155
40 150
30 100
20
50
25
10 NPSH IN FEET
IR ED
NPSH REQU
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
47
FPR Performance Curves
Model: 752 (3500 RPM, Inlet 3”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
500 100
150
IMPELLER DIAMET
450 250 ER 90
250
125
400 250 HE 80
AD
250
CA
PA
CI
T
250 50 hp Y
350 250 40 hp 70
100 250
250
250
30 hp
300 60
250 15 hp 20 hp 25 hp
250
75 250 50
200 40
50
150 30
100 20
25
ED
NPSH REQUIR
50 10 NPSH IN FEET
0 0 0
M3/HR. 0 10 20 30 40 50 60 70 80
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
48
FP/FPX/FPR Performance Curves
Model: 3452 (3500 RPM, Inlet 3”, Outlet 2”)
OF HEAD
OF HEAD
METERS
FEET
120 400
250 IMP
ELL
ER D
245 IAM
ETE
240 R
350
235
100
230
225
300
220 40 hp
215 30 hp
80
HE
AD
210
250
CA
25 hp
PA
205
CIT
Y
200 20 hp
50 hp
15 hp
60 200 195
60 hp
150
40
100
20
50
NPSH IN FEET
20
D
NPSH REQUIRE
0 0 0
GPM 0 100 200 300 400 500 600 700 800
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
49
FP/FPX/FPR Performance Curves
Model: 3552 (3500 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD
OF HEAD
METERS
FEET
500
140
450
IMPELLER DIAMETER
250
HEAD
120 245 CAPA
CITY
400 240
235 100 hp
230
75 hp
100 350 225
220 60 hp
215
50 hp
300 210 40 hp
25 hp 30 hp
205
80
200
250 195
60 200
150
40
100 50
20
50 25 NPSH IN FEET
NPSH REQUIRED
0 0 0
GPM 0 75 150 225 300 375 450 525 600 675 750
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
50
FP/FPX/FPR Performance Curves
Model: 3552-4” (3500 RPM, Inlet 4”, Outlet 2.5”)
OF HEAD
OF HEAD
METERS
FEET
500
140
450
250
120
400
240
100 350
230
220
300
100 hp
210
80 75 hp
30 hp 60 hp
250 200
25 hp 50 hp
190 40 hp
60 200
150
40
100 50
20
50 25 NPSH IN FEET
E QUIRED
NPSH R
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
51
FPR Performance Curves
Model: 3642 (3500 RPM, Inlet 4”, Outlet 4”)
OF HEAD
OF HEAD
METERS
FEET
90 300
ETER
LER DIAM
IMPEL
80 220
250 HEA
DC
APA
CIT
Y
70 210
75 hp
100 hp
60 200 200
60 hp
50 hp
190 40 hp
50
150 180
40 170
30 100
20
50
10
0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
52
FPR Performance Curves
Model: 3652 (3500 RPM, Inlet 4”, Outlet 2.5”)
OF HEAD
OF HEAD
METERS
FEET
500
140
IMPELLER DIAMETER
450 250
120
HE
400 240 AD
CA
PA
230 CIT
Y
150 hp
50 hp
210
300 40 hp 125 hp
60 hp 75 hp
80 200 100 hp
250
60 200
150
40
100
20
50
0 0
CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
53
FP Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
D
H B OUTLET
C
198
J (7.80")
ØK
ØG
INLET
180
(7.09")
210
98 (8.27")
(3.88")
180 ADJ. LEGS
36(1.42") X 16(.63") SLOT (7.09") F
(4 PLACES) (OPTIONAL)
356 38 (1.50")
(14.00") E MAX. ADJ.
203
(8.00")
1265000384 REV-
54
FP Double Flange Dimensional Drawing [Frame Sizes 182TC–286T(S)C]
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
J L D
H B OUTLET
C
INLET A
BALDOR
ØK
250 ØE
(9.84")
290
M (11.42")
ADJ. BASE
300 (OPTIONAL)
19(.75") X 35(1.38") SLOT (11.81") F N
(4 PLACES) 559 300
(22.00") E (11.81")
1265000386 REV-
55
FP Double Flange Dimensional Drawing [Frame Sizes 324T(S)C–365T(S)C]
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
H Q D
C L B OUTLET
INLET A
BALDOR
ØJ
K ØE
117.5
ØR (4.62")
ADJ. LEGS
(OPTIONAL)
M P 44.5 (1.75") N il-0661
S MAX. ADJ.
1265000715 REV-
56
FPX Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
F N D
C J B
OUTLET
A
ØE
ØG
H
INLET
98 ADJ. LEGS
ØP (3.88") (OPTIONAL)
K M
38 (1.50")
Q MAX. ADJ. L il-0657
57
FPX Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
H Q D
C L B OUTLET
INLET A
BALDOR
ØJ
K ØE
117.5
ØR (4.62")
ADJ. LEGS
(OPTIONAL)
M P 44.5 (1.75") N il-0661
S MAX. ADJ.
MOTOR HP
PUMP MODEL INLET OUTLET DIMENSIONS IN MILLIMETERS (INCHES) MOTOR DIMENSIONS IN MILLIMETERS (INCHES)
A B C D ØE 1750 RPM 3500 RPM FRAME H ØJ K L M N P Q ØR S
250 170 167 202.5 406 388 263 133 189 140 216 108 200 10.3 470
FPX 1051 4" 4" 7.5 HP 213TC
(9.84") (6.69") (6.57") (7.97") (15.98") (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (7.87") (13/32") (18.50")
250 170 110.5 146 406 416 263 133 189 178 216 108 200 10.3 470
FPX 1151 4" 4" 10 HP 215TC
(9.84") (6.69") (4.35") (5.75") (15.98") (16.40") (10.34") (5.25") (7.46") (7.00") (8.50") (4.25") (7.87") (13/32") (18.50")
250 170 110.5 146 406 447 270 159 226 210 254 121 200 13.5 444
FPX 1161 4" 4" 15 HP 254TC
(9.84") (6.69") (4.35") (5.75") (15.98") (17.59") (10.62") (6.25") (8.88") (8.25") (10.00") (4.75") (7.87") (17/32") (17.50")
250 170 111 146 406 499 320 159 239 254 254 121 200 13.5 470
FPX 1161 6" 4" 20 HP 256TC
(9.84") (6.69") (4.37") (5.75") (15.98") (19.66") (12.60") (6.25") (9.42") (10.00") (10.00") (4.75") (7.87") (17/32") (18.50")
200 91 104 153 270 588 367 178 333 241 279 121 200 13.5 444
FPX 1742 2.5" 2" 25 HP 284TC
(7.87") (3.58") (4.09") (6.02") (10.63") (23.13") (14.44") (7.00") (13.11") (9.50") (11.00") (4.75") (7.87") (17/32") (17.50")
191 95 115.5 164.5 260 588 367 178 333 241 279 121 200 13.5 444
FPX 3532 2.5" 2" 25 HP 284TSC
(7.52") (3.74") (4.55") (6.48") (10.24") (23.13") (14.44") (7.00") (13.11") (9.50") (11.00") (4.75") (7.87") (17/32") (17.50")
211 115 118 164.5 290 588 367 178 333 279 279 121 200 13.5 444
FPX 3542 3" 2.5" 30 HP 286TC
(8.31") (4.53") (4.64") (6.48") (11.42") (23.13") (14.44") (7.00") (13.11") (11.00") (11.00") (4.75") (7.87") (17/32") (17.50")
211 140 114 160.5 350 588 367 178 333 279 279 121 200 13.5 444
FPX 3452 3" 2" 30 HP 286TSC
(8.31") (5.51") (4.49") (6.32") (13.78") (23.13") (14.44") (7.00") (13.11") (11.00") (11.00") (4.75") (7.87") (17/32") (17.50")
231 140 119 170.5 350 636 413 203 371 267 318 133 216 16.7 470
FPX 3552 3" 2.5" 40 HP 324TC
(9.09") (5.51") (4.68") (6.71") (13.78") (25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 267 318 133 216 16.7 470
40 HP 324TSC
(25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 305 318 133 216 16.7 470
50 HP 326TC
(25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 305 318 133 216 16.7 470
50 HP 326TSC
(25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")
il-0660
58
FPR Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
P B
Outlet
L T D
A
Inlet
X
Ø V Adjustable Legs
(Optional) R
Z
Q S Y
W Max. Leg
Adjustment
1265000202 Rev A
MOTOR HP MOTOR
L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET A B C D E
1750 RPM 3500 RPM FRAME
284 175 89 133 101.6 140 127 120 8.7 356 98 38 57.2 108 44.5 106.5 139.5 150
1 HP 1.5 HP 143TC FPR 701/702 1.5" 1.5"
11.18" 6.89" 3.5" 5.25" 4" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 4.25" 1.75" 4.19" 5.49" 5.91"
284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 144 58 113 145 185
1.5 HP 145TC FPR 711/712 2" 1.5"
11.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 5.67" 2.28" 4.45" 5.71" 7.28"
284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 170 79 113 145 230
2 HP 2 HP 145TC FPR 721/731/722 2" 1.5"
11.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 6.69" 3.11" 4.45" 5.71" 9.06"
340 221 114 149 114 191 108 169 10.3 356 98 38 69.9 195 96 101 136 270
3 HP 182TC FPR 741/742 2.5" 2"
13.39" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.68" 3.78" 3.98" 5.35" 10.63"
354 221 114 149 114 191 108 169 10.3 356 98 38 69.9 200 91 104 145.5 270
3 HP 182TC FPR 1741/1742 2.5" 2"
13.94" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.87" 3.58" 4.09" 5.73" 10.63"
354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 190 80 118 157.5 230
5 HP 184TC FPR 3521/3522 2.5" 2"
13.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.48" 3.15" 4.65" 6.2" 9.06"
354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 191 95 115.5 157.5 260
5 HP 184TC FPR 3531/3532 2.5" 2"
13.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.52" 3.74" 4.55" 6.2" 10.24"
423 221 114 149 140 191 108 169 10.3 356 98 38 69.9 211 115 118 157.5 290
7.5 HP 184TC FPR 3541/3542 3" 2.5"
16.65" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 4.53" 4.65" 6.2" 11.42"
403 260 133 187 140 216 108 169 10.3 356 98 38 88.9
7.5 HP 213TC
15.87" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
403 260 133 187 178 216 108 169 10.3 356 98 38 88.9
10 HP 215TC
15.87" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
416 260 133 187 178 216 108 169 10.3 356 98 38 88.9
10 HP 215TC
16.38" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
515 260 133 187 178 216 108 169 10.3 356 98 38 88.9
15 HP 215TC
20.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
499 327 159 244 210 254 102 169 13.5 406 98 38 108.0
15 HP 254TC
19.65" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 169 13.5 406 98 38 108.0
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 169 13.5 406 98 38 108.0
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
588 371 178 333 241 279 121 179 13.5 445 118 45 120.7
25 HP 284TSC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 241 279 121 179 13.5 445 118 45 120.7
25 HP 284TC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 179 13.5 445 118 45 120.7
30 HP 286TSC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 179 13.5 445 118 45 120.7
30 HP 286TC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
636 419 203 359 267 318 121 179 16.7 470 118 45 133.4
40 HP 324TSC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 267 318 121 179 16.7 470 118 45 133.4
40 HP 324TC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 179 16.7 470 118 45 133.4
50 HP 326TSC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 179 16.7 470 118 45 133.4
50 HP 326TC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
1265000463
59
FPR Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
L T D
P B
Z C Outlet
Ø E
Inlet
M
Adjustable Legs R X
Ø V
(Optional)
Q S
Y
W Max. Leg
Adjustment
1265000203 Rev C
MOTOR HP MOTOR
L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET A B C D E
1750 RPM 3500 RPM FRAME
313 221 114 149 114 191 108 160 10.3 356 98 38 69.9 205 145 99 142 379
3 HP 182TC FPR 751/752 3" 2"
12.32" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 8.07" 5.71" 3.9" 5.59" 14.92"
348 221 114 149 114 191 108 160 10.3 356 98 38 69.9 211 140 114 160.5 350
3 HP 182TC FPR 3451/3452 3" 2"
13.7" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 5.51" 4.49" 6.32" 13.78"
347 221 114 149 140 191 108 160 10.3 356 98 38 69.9 230 140 119 170 350
5 HP 184TC FPR 3551/3552 3" 2.5"
13.66" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.06" 5.51" 4.69" 6.69" 13.78"
386 221 114 149 140 191 108 160 10.3 356 98 38 69.9 250 170 167 202.5 406
5 HP 184TC FPR 1051 4" 4"
15.2" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.84" 6.69" 6.57" 7.97" 15.98"
386 221 114 149 140 191 108 160 10.3 356 98 38 69.9 250 170 110.5 146 406
7.5 HP 184TC FPR 1161 4" 4"
15.2" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.84" 6.69" 4.35" 5.75" 15.98"
388 260 133 187 140 216 108 160 10.3 356 98 38 88.9
7.5 HP 213TC
15.28" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
388 260 133 187 178 216 108 160 10.3 356 98 38 88.9
10 HP 10 HP 215TC
15.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
436 260 133 187 178 216 108 160 10.3 356 98 38 88.9
15 HP 215TC
17.17" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
447 327 159 244 210 254 102 160 13.5 406 98 38 108
15 HP 254TC
17.6" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
491 327 159 244 254 254 102 160 13.5 406 98 38 108
20 HP 256TC
19.33" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 160 13.5 406 98 38 108
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
588 371 178 333 241 279 121 174 13.5 445 118 45 121
25 HP 284TC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 241 279 121 174 13.5 445 118 45 121
25 HP 284TSC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 174 13.5 445 118 45 121
30 HP 286TC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 174 13.5 445 118 45 121
30 HP 286TSC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
636 419 203 359 267 318 121 209 16.7 470 118 45 133
40 HP 324TC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 267 318 121 209 16.7 470 118 45 133
40 HP 324TSC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 209 16.7 470 118 45 133
50 HP 326TC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 209 16.7 470 118 45 133
50 HP 326TSC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
685 470 229 383 286 356 89 209 16.7 508 127 45 149
60 HP 364TC
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 286 356 89 209 16.7 508 127 45 149
60 HP 364TSC
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 311 356 89 209 16.7 508 127 45 149
75 HP 365TC
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 311 356 89 209 16.7 508 127 45 149
75 HP 365TSC
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
1265000463
60
FPR Double Flange Dimensional Drawing [Model 4001]
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
232 239.5
A [9.13"] [9.43"] 228.5
127.8 D [9.00"]
4" SANITARY [5.03"]
CLAMP
300.5
[11.83"]
440
C [ 17.32"]
6" SANITARY
CLAMP
ADJUSTABLE LEGS
K (OPTIONAL)
E G
4X ØH
J
44.4 [1.75"]
MAX. ADJ. F
1265000053
8/19/02
MOTOR MOTOR
A B C D E F G ØH J K
HP FRAME
636 418 203 371 267 317 133 16.7 470 117
40 HP 324TC
25" 16.5" 8" 14.6" 10.5" 12.5" 5.2" 0.7" 18.5" 4.6"
636 418 203 371 305 317 133 16.7 470 117
50 HP 326TC
25" 16.5" 8" 14.6" 12" 12.5" 5.2" 0.7" 18.5" 4.6"
684 470 229 380 286 355 149 16.7 508 127
60 HP 364TC
26.9" 18.5" 9" 15" 11.3" 14" 5.9" 0.7" 20" 5"
684 470 229 380 311 355 149 16.7 508 127
75 HP 365TC
26.9" 18.5" 9" 15" 12.2" 14" 5.9" 0.7" 20" 5"
782 520 254 477 349 406 168 20.6 508 127
100 HP 405TC
30.8" 20.5" 10" 18.8" 13.7" 16" 6.6" 0.8" 20" 5"
1265000054
1/28/2008
61
CENTRIFUGAL POSITIVE DISPLACEMENT MIXING & BLENDING