Centrifugal Pump

Performance Curves and Technical Information


OF HEAD

OF HEAD
METERS

FEET

110
IMPELLER DIAMETER
250
100 50
30 245
HE
AD
240 CA
90 PA
C ITY
235 5 hp
3 hp

80 230 40
225
220 7½ hp
215
70
210
20 205
200
60 30

50

40 20

10
30

20 10

NPSH REQUIRED
NPSH IN FEET

10

0 0 0

GPM 0 20 40 60 80 100 120 140 160

M3/HR. 0 5 10 15 20 25 30 35

CAPACITY
Table of Contents
Introduction.........................................................................................................................2

Pump basics..........................................................................................................................4

Selecting a pump..................................................................................................................5

Pump inquiries application data sheet................................................................................7

How to calculate required pressure.....................................................................................8

Determining net positive suction head (NPSH)..................................................................8

Specific gravity and viscosity chart......................................................................................9

Conversion factors..............................................................................................................10

Vapor pressure chart..........................................................................................................10

Tubing friction loss chart...................................................................................................11

Fristam centrifugal pump options.....................................................................................12

Pharmaceutical options......................................................................................................13

Pump Performance Curves: 1750 RPM Pump Performance Curves: 3500 RPM
FP/FPX/FPR Composites.............. 14 FP/FPX/FPR Composite................ 34
701 ................................................ 16 702 ................................................ 36
711 ................................................ 17 712 ................................................ 37
721 ................................................ 18 722 ................................................ 38
3521............................................... 19 3522............................................... 39
731 ................................................ 20 732 ................................................ 40
3531............................................... 21 1732............................................... 41
741 ................................................ 22 3532............................................... 42
1741............................................... 23 742 (2)........................................... 43
3541............................................... 24 1742 (2)......................................... 45
751 ................................................ 25 3542............................................... 47
3451............................................... 26 752 ................................................ 48
3551............................................... 27 3452............................................... 49
1051............................................... 28 3552............................................... 50
1151............................................... 29 3552-4”.......................................... 51
1161 (2)......................................... 30 3642 .............................................. 52
4001............................................... 32 3652 .............................................. 53
4001X............................................. 33

Dimensional Drawings
FP Single Flange..........................................................................................................54
FP Double Flange (2)...................................................................................................55
FPX Single Flange........................................................................................................57
FPX Double Flange......................................................................................................58
FPR Single Flange........................................................................................................59
FPR Double Flange (2).................................................................................................60

1
Fristam Pride
Fristam is a global manufacturer of sanitary centrifugal and positive displacement pumps,
mixers and blenders respected for unmatched performance, reliability, and technical superiority.

Fristam manufactured its first pump in 1931. Today, Fristam equipment is used by many of the
world’s top dairy, beverage, brewing, bio-pharmaceutical, and food processing companies.

High Lifetime Value


The solid design, precise machining, and robust construction of a
Fristam pump ensures efficiency and operational reliability. Fristam
pumps simply run better and last longer.

Quality Control
Fristam Pumps USA designs, manufactures, and assembles its pumps
in the United States. Each component is carefully checked from raw
material through final assembly.

The result of this effort is a pump worthy of the valuable product your
company produces. To achieve the highest level of quality, Fristam offers
the most comprehensive testing and documentation packages in the
sanitary pump industry.

2
Experience and Expertise
Over the past 100 years, Fristam has built its reputation with experience, attention
to detail, and a willingness to adapt to changing needs. Fristam’s strong applications
engineering capabilities make it the most reliable source for straight, smart answers to
process needs.

Fast Delivery, New Solutions


Manufacturing in the United States ensures Fristam customers
receive prompt delivery, not lead times measured in months.

Additionally, if a new production challenge arises, Fristam is


responsive and able to develop new solutions quickly.

Dedicated Support
Fristam’s dedication and quality service do not end with your initial
purchase. An international network of manufacturing facilities, sales
offices and distribution supports Fristam’s commitment to customer
satisfaction.

Why Customers Choose Fristam


“simply better pumps”
“reliable, dependable”
“high standard for sanitization and performance”
“knowledgeable people who help solve problems”

3
Pump Basics: Background Information
Pump Series – FP, FPX, or FPR
The FP, FPX, and FPR Series pumps are manufactured of
316L stainless steel and have the same pump head. The FP
incorporates a heavy-duty pedestal flange between the motor

22
2
72

35
and pump head. The FPX is a motor mounted pump used

PRESSURE
for standard duties. The FPR has a front-loading seal for
easy changeout and may be used in place of either the FP
or FPX. Double seals are only available in the FP and FPR.
The FP is used for vacuum withdrawal, high temperature,
high viscosity, aseptic processes and other demanding

FPR 3522
FPR 722
applications.

Pump Model/Housing Size


Fristam offers both volute and non-volute (circular) housings
in many sizes to best match different process needs. The
700 and 1700 series pumps are non-volute and designed
VOLUME
for lower capacities. Their shorter, steeper curves provide
better efficiencies on low flows and superior accuracy when
used with control devices. The 1050, 1150, 3400 and 3500 Figure 1
series pumps are volute high capacity pumps. Their long, Horsepower
flat curves provide greater capacity and an ability to provide Horsepower must be matched to a given duty or duties. The
steady discharge pressure over a wide flow range. requirements are determined by individual curves. Enough
horsepower must be supplied to handle the most demanding
Speed duty, often the duty requiring the most flow, pressure or the
Pumps are sized using two standard speeds, 1750 and pumping of the heaviest product.
3500 RPM. Speed selection is determined when selecting
a housing. The last digit of the Fristam model number Net Positive Suction Head (NPSH)
003.p3 fig.1
indicates the speed. All models ending in 1 are 1750 RPM. All Product must be forced into a centrifugal pump for it to
models ending in 2 are 3500 RPM. function properly. This force is called NPSH. Your process
must have sufficient NPSH available to meet or exceed the
Efficiency NPSH required.
The efficiency of centrifugal pumps varies over the individual
curve. The most efficient point of two curves is illustrated in Seals
Figure 1. When sizing, it is helpful to select a pump whose Fristam offers a wide selection of seals. Most processes
curve puts the duty point as close to this bend in the curve require a standard single seal of chrome oxide coated
as possible. stainless steel on carbon. More difficult applications will
require harder seal materials such as silicon carbide.
Impeller Size Double seals are used when a flush is required, where
Within a given housing, the impeller diameter will determine abrasion or stickiness is a problem, for vacuum withdrawal
the flow and pressure produced. Pressure results from the or if a sterile barrier is required between the process
velocity achieved within the pump. The highest velocity and atmosphere.
occurs at the tip of the impeller and is directly proportional
to the square of the impeller diameter. At a given speed,
a larger diameter impeller will impart more velocity and
produce more pressure.
4
Selecting a Fristam Pump: A Step by Step Guide
Special Considerations Example
All curves are based on 70°F water. If your process involves As an example, size a pump to pump 50 gallons per minute
products under vacuum, with high viscosity, high specific and generate 135 feet of head. In the composite shown
gravity, high temperatures, undissolved solids or entrained in Figure 2, find the intersection point of 50 GPM on the
air there are special considerations which affect pump bottom of the graph and 135 feet on the side. The pump
selection. In such cases, please consult Fristam Pumps or curve directly above the duty point is the 722. In this
your local Fristam distributor. example, model 742 (the next size larger) might also be
considered. A quick review of the duty point on their
Selecting a Pump Model From the individual curves reveals the 722 will be more efficient than
the 742.
Composite Curves
Composite curves appear at the beginnings of the low- and
high-speed sections. To select the correct pump model Considering Speed and Efficiency
from the composite curves, find the desired flow rate along If both pumps are the same speed, consider which will be
the bottom scale and the desired pressure on the left-hand more efficient based on the information discussed in Figure
vertical scale. Find the point where the vertical line from the 1. If both a high and low speed pump can handle the duty,
flow rate and a horizontal line from the pressure intersect. the high speed will generally be more economical, but the
The curve immediately above this point will be most low speed model may have a lower NPSH requirement.
suitable.
Choosing Impeller Size and Horsepower
Figure 2 Having chosen a pump model based
on the first two steps, find the specific
OF HEAD
METERS

curve for the pump model chosen.


FT. OF
HEAD

To determine the impeller diameter


450 and horsepower move vertically from
420 the flow and horizontally from the
120 390 pressure or head desired. Find the
360
intersecting point.
100 330
3552
752 The next higher curve indicates
300
the correct impeller diameter. The
270
80
diagonal line immediately to the right
240
of the intersection identifies the motor
60
210 horsepower required.
1742
180
742
150
40 1732 3532 3452
120
732
722
90
3542
20 3522
60
712
30
702
0 0
0 50 100 150 200 300 400 500 500 700 800 GPM

0 50 100 150 200 M3/HR

5
Example Seal Selection: Single or Double
Using our previous example of 50 gallons per minute and 135 Many applications require only single seals. Double seals
feet of head, we can determine from Figure 3 that the impeller are recommended for applications involving:
diameter should be 145 millimeters (5.7 inches). The motor • Abrasive products
required is 5 horsepower. • Sticky products
• Vacuum >14” Hg
Checking NPSH (Net Positive Suction Head) • Temperature regulation
To assure there is sufficient product pressure at the inlet of
the pump the suction conditions need to be checked. The Seal Selection: Materials
NPSH required can be determined by finding the point on Recommended seal material configurations:
the individual pump curve where the vertical line from the • Simple transfer applications: FR-N-(K)*
desired flow rate intersects the NPSH curve. From this point, • Sticky applications: FR-C-(N)*
a horizontal line to the right will intersect the NPSH scale at • Pharmaceutical applications, chlorine, brine: C-C-(N)*
the net positive suction head required.* * rotating seal, stationary seal, (flush/double seal)

The procedure for determining the NPSH available is N = Carbon
described in the “How To Calculate Required Pressure” section C = Silicon Carbide
of this book. When the NPSH available is determined, it must FR = Chrome Oxide Coated Stainless Steel
meet or exceed the NPSH required for the pump to function K = Ceramic
properly. If the NPSH available is
insufficient, a change to the inlet Figure 3
OF HEAD

OF HEAD
METERS

conditions, an enlarged inlet or


FEET

another pump selection may be


150
required. 45
IMPELLER DIAMETER
145

Example 40 140

A 722 pumping 50 GPM against 120 135


35 5 hp HE
135 feet of head will require 130
A
D
CA

6 feet or more of NPSH. The


PA
CIT
125 3 hp Y
30 2 hp 7½ hp
installation must provide at least 120
90
6 feet of head.
25 115

110

Elastomers 20
Viton is the standard seal 60

elastomer and BUNA is standard 15


for the cover gasket. Other
materials and combinations 10
30
are available to meet your
application or process needs. 5
10
NPSH IN FEET

NPSH REQUIRED

0 0 0
GPM 0 30 60 90 120 150

M3/HR. 0 5 10 15 20 25 30

CAPACITY

*Please note that the NPSH values shown are for full size impellers. Smaller impellers may require somewhat greater NPSH.
6
Pump Inquiry Application Data Sheet
The following information is required to properly process an inquiry:
Requested by______________________________________________________ Date___________________________________
Customer________________________________________________________________________________________________
Address__________________________________________________________________________________________________
Telephone___________________________________ Fax__________________ Email___________________________________
Description of product to be pumped__________________________________________________________________________
________________________________________________________________________________________________________
Temperature___________ Specific Gravity______________________________ or Density_________________________ lb./gal.
Viscosity____________________________________ Centipoise (CPS) or other
Desired Flow Rate____________________________ GPM or lb./hr.
*Discharge Head_____________________________ ft. or PSI

Suction Conditions
Is the pump withdrawing from a vacuum?_________ Yes__________No
If so, how much?_____in. Hg.
Is the product level on the inlet side of the pump above or below the center line of the pump inlet?
Above_________________ Below________________ By how much?_________ in. or ft.
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
No. of size of valves in suction piping:
_____________________ No.___________________ Size (in.)
_____________________ No.___________________ Size (in.)
Other equipment in the suction piping________________________________________________________________________
________________________________________________________________________________________________________

*If you do not know the desired discharge head, please provide the following:
Discharge Conditions
Is the final destination of the pump above or below the center line of the pump inlet?
Above_________________ Below________________ By how much?_________ in. or ft.
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
Tubing _______________ in. Diameter___________ Length_______________ No. of elbows______________ No. of tees
No. and size of valves in discharge piping:
_____________________ No.___________________ size (in.)
_____________________ No.___________________ size (in.)
_____________________ No.___________________ size (in.)
Other equipment and the drop or pressure requirement (PSI) in the discharge piping__________________________________
________________________________________________________________________________________________________

7
How To Calculate Required Pressure
Example:
Find the head under these conditions: Pump is drawing
299.2 ft.
from an open tank to discharge through a heat exchanger
into an open tank that is 20 ft. above the pump. The supply
is 8 ft. above the pump. 50 GPM flow is required. Outlet Open Tank
1 1/2" Pipe Water 62

Solution: 20 ft. Tank


Heat
System Head
The total head of a system against
180
1. Height to be pumped is 20 ft. minus 8 ft. =12.0 ft. Exchanger which a pump must operate is made
up of the following components:
Inlet
8 ft. 1 1/2" Pipe 1. Static Head
2. Friction loss from pipe is 2. Difference of pressures
existing on the liquids
(8 ft. + 10 ft. + 20 ft. + 299.2 ft. = 337.2 ft.) 3. Friction
337.2 x .25 ft./ft. =84.3 ft. 10 ft.

3. Friction loss from 3 elbows is = 0.6 ft. = 0.6 ft.

4. *Heat Exchanger loss 2.31 times 16.5 PSI =38.1 ft.

The Total Head Loss is. . . . . . . . . . . . . . . . . . . . 135.0 ft.


*Heat Exchanger information supplied by manufacturer.

Determining Net Positive Suction Head (NPSH)


Fristam pumps are well known for requiring less net The pump model required is a 722 with a 145 mm impeller
positive suction head (NPSH) available than other sanitary (see “Selecting a Fristam Pump”). From the actual pump
centrifugal pumps. However, due to the hydraulic principles curve or from the example in “Selecting a Fristam Pump,”
involved, some level of NPSH is still required in order for we see that the NPSH required is 3 feet.
the pump to run efficiently and without cavitating.
Assuming 10 feet of 1 1/2 inch line and one elbow in the
The NPSH required for each Fristam pump model has been suction line, 8 feet of height of liquid above the pump
determined by careful testing. The results of these tests are center line and pumping 180°F water from an open tank,
illustrated by the NPSH curve under the performance curves we can compute the NPSH available.
for each pump model.
NPSH available = Physical height of liquid + atmospheric
To determine the NPSH available, first add the physical pressure - friction losses - vapor pressure (see “Vapor
height of the liquid above the centerline of the pump inlet Pressure Chart”).
to the pressure above the liquid (in an open tank this is
atmospheric pressure). From this total, subtract the friction NPSH available = 8 ft. + 33.9 ft. - 4.7ft. - 17.3 ft. = 19.9 ft.
losses of the line and fittings on the suction side and the
vapor pressure of the liquid at the operating temperature. Since the NPSH available of 19.9 feet is greater than
The remainder is the NPSH available. This number must the NPSH required 3 feet, the pump has sufficient NPSH
meet or exceed the NPSH required in order for the pump to available to run properly.
function properly. As an example, figure the NPSH available
and required to pump 50 GPM and generate 135 feet water
column of pressure.

8
Specific Gravity and Detailed information is available on viscosity correction factors. Contact
Fristam Pumps for details. The following viscosities may vary, depending

Viscosity for Various Liquids upon products, formulas, and processes used by processors.

Product SP. Visc. Temp Condition Product SP. Visc. Temp Condition
Gr. (cps) °F Gr. (cps) °F

Acetone 0.80 1 70 Milk–Sweetened 1.25 2000 50


Acid: Condensed 500 150
Acetic 1.01 1 100 5% Milk of Magnesia 1.08 200 70
Citric 1.02 1 140 10%
Lactic 1.10 1 140 Oils:
Nitric 1.02 18 70 Butter 0.90 40 70
Alcohol: Corn 0.93 150 60
Ethyl 0.82 1.4 70 Frying 0.90 10 400
Methyl 0.79 0.6 70 Lard 0.96 165 80
Alum 1.33 80 40 50% Conc. Mineral 0.93 150 70
Olive 0.92 110 60
Barbecue Sauce 1.10 150 70 33° Brix Peanut 0.92 100 60
Beer 1.02 1 40 Soybean 0.93 95 60
Beverage Concentrate 1.26 80 80 Vegetable 0.92 40 100
Blood 1.00 5 20
Brine 1.10 to 1 40 Sodium Chloride 1.20 Paint Solvents 0.90 10 70
1.20 Paper Coatings 1.05 400 70 35% TS
Butter–Melted 0.95 90 90 Paraffin 0.90 9 140
Buttermilk 1.04 20 40 Pear Puree 1.30 4000 160 Thixotropic
Perfume 0.95 1 70
Carbon Tetrachloride 1.59 1 70 Pie Filling 1.20 200 140
Catsup 1.15 100 60 Propylene Glycol 1.02 20 30 50%
Chocolate Bar Coating 1.08 65 120
Cream 0.99 20 40 40% Fat Sauce–Apple 2000 71
800 190
Dye, Water Base 1.10 10 70 Salad Dressing 0.96 5000 75
Shampoo 1.00 350 70
Egg—Whole 1.04 68 40 Sorbitol 1.30 150 70 75%
Egg Yolk 1.12 400 68 Soup, Clear 1.00 20 160
200 86 Spaghetti Sauce 1.10 200 140
Ethylene Glycol 1.10 18 70 Syrups:
Corn 1.39 240 180 40° Be
Fat–Animal Melted 0.90 43 110 Dextrose 1.35 280 180 77° Brix
HFCS 42 1.35 160 70 42% TS
Glaze–Donut 1.22 55 120 HFCS 55 1.35 800 70 55% TS
Invert 1.38 800 80 76° Brix
Honey 1.30 230 100 81.2° Brix Maple 1.37 600 68
1500 70 Sugar 1.33 220 80 68° Brix
Soft Drink 1.26 80 80
Ice Cream Mix 1.15 300 40 Varies
Ink, Printer’s 1.20 520 130 Toulene 0.87 1 70
Tomato Paste 1.14 150 75 11% TS
Juice–Single Strength: 1.14 100 180 11% TS
Apple, Clear 1.05 20 140 1.14 1500 200 17% TS
Cranberry 1.03 10 140
Grape 1.05 25 140 Varnish 0.90 125 100
Orange 1.05 20 140 Vinegar 1.01 1 70
Tomato 1.03 180 140
Water 1.00 1 70 Includes WFI
Juice–Concentrate: Wax, Liquid 1.00 75 70
Apple 1.36 600 50 Thixotropic Whey:
Cranberry 1.03 250 100 Thixotropic Acid/Sweet 1.06 2 100
Grapefruit 1000 38 Thixotropic Condensed 1.11 20 100 27% TS
Orange 1.32 5000 38 Thixotropic 1.20 800 40 40% TS
1.20 400 130 50% TS
Liqueurs 1.15 10 70 1.20 550 65 50% TS
1.24 1500 65 60% TS
Margarine 0.93 50 120 Sweetened 1.20 900 55 50% TS
Milk–Whole 1.03 1 40% TS 1.24 600 145 60% TS
Milk–Concentrated 1.10 1000 50 40% TS Salt 1.06 2 80
1.30 100 131 75% TS Wort 1.05 100 150
Milk–Concentrated 1.20 20 110 45% TS
Skim 1.10 95 70 30% TS Yeast–Brewer’s
Milk–Evaporated 1.17 60 70 48% TS Fermenting 1.10 150 40 20% TS
Milk–Skim Condensed 1.20 20 110 45% TS Yeast Slurry 1.10 270 45 35% TS
Yogurt Mix 1.03 20 40

9
Conversion Factors

Length Pressure (continued)
Meters x 3.281 = Feet Atmosphere x 33.9 = Feet of Water
Centimeters x 0.394 = Inches PSI x 2.31 = Feet of Water
Millimeters x 0.0394 = Inches Inches of Hg. x 1.13 = Feet of Water

Mass Flow
Kilograms x 2.2 = Lbs. Lbs. Of Water/Hour x 0.002 = GPM
Gallons Of Water x 8.34 = Lbs. Lbs. Of Fluid/Hour x 0.002 = GPM
Cubic Feet of Water x 62.4 = Lbs. Specific Gravity
Pounds x 0.454 = Kilograms Cu. Meter/Hour x 4.4 = GPM
Kg. Of Water/Minute x 0.264 = GPM
Volume Liters/Minute x 0.264 = GPM
Liter x 0.264 = Gallon GPM x 3.785 = Liters/Minute
Cubic Feet x 7.48 = Gallon
Lbs. Of Water x 0.119 = Gallon Power
Imperial Gallon Liquid HP = GPM x Head ft. x Specific Gravity
(British) x 1.2 = Gallon (U.S.) 3960
U.S. Gallon x 3.785 = Liter
BHP = GPM x Head ft. x Specific Gravity
Pressure 3960 x Pump Efficiency
Feet of Water x 0.433 = PSI
Inches of Hg. x 0.491 = PSI Viscosity
Atmosphere x 14.7 = PSI Centipoise = Centistokes
Meters of Water x 1.42 = PSI Specific Gravity
Kilograms/sq.
Centimeter x 14.22 = PSI Centistokes x 4.64 = SSU (Approx.)
Bar x 14.7 = PSI
Temperature
(1.8 X °C) + 32 = °F
.555 (°F – 32°) = °C
Degrees Kelvin – 273.2 = Degrees Centigrade

Vapor Pressure Chart


VAPOR PRESSURE OF WATER
50

40

30

PRESSURE
(psia)
20

10

0
0 32 50 100 150 200 250 300
TEMPERATURE (F)

10
Loss of Head Due to Friction in Feet per Foot of Stainless Steel Tubing
and in Feet for Sanitary Fittings
Notes:
1. Flow Elbows—R/D = 1.5 A
2. Flow Through Tees—Flow A
to B Port C capped off.
C B
3. Test Medium—Water at 70°F
4. 16 gauge tubing was used for the measurements when the outer diameter (O.D.)
was between 1" - 3" and 14 gauge tubing was used with the 4" O.D. measurement.

*Calculated data for estimating purposes only. Consult your tubing manufacturer with specific questions.

Capacity in O.D. - 1” O.D. - 1.5” O.D. - 2 ” O.D. - 2.5” O.D. - 3” O.D. - 4”


U.S. G.P.M. I.D. - .870” I.D. - 1.370” I.D. - 1.870” I.D. - 2.370” I.D. - 2.870 ” I.D. - 3.834”
Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee
2 .01 .01 .1
4 .025 .02 .2
5 .035 .025 .25
10 .12 .06 .4 .02 .01 .15 .005 .015 .1
15 .25 .1 .8 .04 .02 .25 .013 .02 .15
20 .43 .22 1.5 .06 .03 .3 .02 .025 .2 .005 .02 .1 .003 .02 .06
25 .66 .4 2.3 .08 .04 .4 .025 .03 .25 .006 .03 .15 .004 .03 .08
30 .93 .7 3.3 .105 .06 .55 .035 .05 .3 .008 .05 .2 .005 .04 .1
35 1.22 1.25 5.2 .135 .09 .8 .04 .06 .4 .011 .06 .25 .006 .05 .13
40 .17 .11 1.0 .05 .08 .5 .015 .07 .3 .007 .06 .15
45 .21 .16 1.3 .063 .1 .6 .02 .09 .35 .008 .065 .18
50 .25 .2 1.6 .073 .12 .7 .022 .1 .4 .01 .07 .2
60 .34 .35 2.2 .1 .18 .9 .03 .12 .45 .015 .08 .25
80 .57 .76 3.7 .16 .3 1.5 .05 .15 .55 .02 .1 .4
100 .85 1.35 5.8 .23 .44 2.3 .075 .18 .6 .03 .11 .5 .008 .04 .1
120 1.18 2.05 9.1 .32 .64 3.3 .105 .21 1.0 .04 .13 .6 .01 .05 .15
140 .42 .85 4.5 .14 .23 1.25 .05 .16 .8 .013 .06 .2
160 .54 1.13 5.8 .17 .28 1.6 .07 .2 1.1 .015 .07 .25
180 .67 1.45 7.4 .205 .31 2.0 .08 .21 1.3 .02 .08 .3
200 .81 1.82 9.0 .245 .35 2.5 .1 .26 1.6 .025 .09 .4
220 .95 2.22 11.0 .29 .41 3.0 .12 .3 1.9 .028 .1 .5
240 1.10 2.63 13.5 .34 .48 3.7 .14 .33 2.2 .035 .11 .55
260 .39 .53 4.5 .165 .39 2.5 .04 .115 .6
280 .45 .61 5.3 .19 .42 2.8 .045 .12 .65
300 .515 .7 6.2 .22 .5 3.1 .05 .13 .7
350 .68 1.05 8.5 .28 .67 4.1 .07 .15 .9
400 .86 1.55 11.0 .36 .88 5.2 .085 .18 1.2
450 1.05 2.25 13.5 .44 1.1 6.6 .105 .2 1.5
500 .54 1.4 8.0 .13 .23 1.75
550 .64 1.7 9.5 .15 .27 2.1
600 .75 2.05 10.2 .175 .3 2.5
650 .87 2.41 13.0 .2 .34 2.8
700 1.0 2.8 15.0 .23 .4 3.4
750 .26 .43 3.8
800 .3 .5 4.4
850 .33 .56 5.0
900 .37 .62 5.7
950 .41 .7 6.3
1000 .45 .8 7.0
1100 .53 1.06 8.6

11
Fristam Centrifugal Options
SEAL MATERIALS HARDWARE OPTIONS
1st – Rotating Stainless steel flange
2nd – Stationary Aseptic
3rd – Flush (Double) Seal [FP and FPR only] Jacketed housing
Casing drain
Single Seal Bearing block mounted
FR-N – Chrome oxide SS vs. carbon Adjustable base with legs
C-N – Silicon carbide vs. carbon Impeller inducer
C-C – Silicon carbide vs. silicon carbide
FR-C – Chrome oxide SS vs. silicon carbide ELASTOMERS
Viton
Double Seal [FP and FPR only] EPDM
FR-N-N – Chrome oxide SS vs. carbon vs. carbon Buna cover gasket
C-N-N – Silicon carbide vs. carbon vs. carbon Perfluoroelastomer
C-C-N – Silicon carbide vs. silicon carbide vs. carbon USP Class VI Viton and EPDM
FR-C-N – Chrome oxide SS vs. silicon carbide vs. carbon

COMPREHENSIVE DOCUMENTATION PACKAGE


FITTING TYPE
Fristam offers the most comprehensive documentation
Clamp package, with complete traceability of all parts, including
Bevel seat elastomers.
150# flange
300# flange Certified Drawings
NPT Mill Certification
DIN Material Verification
Butt weld Conformance
I-Line (female) Warranty Statement
Others Certified Finish
Passivation of Pump
Stainless Steel Tag
FINISH AND MATERIAL OPTIONS Paper Location Tag
32 Ra Certified Welding
25 Ra Hydrostatic Test
20 Ra Dynamic Seal Test
15 Ra Short Run Test
Electropolish Performance Test
Passivation NPSH Test
Tungsten carbide coating Witness Test
316L low ferrite Vibration Test
Ferrite Test

12
Pharmaceutical Options
All standard stainless steel components are 316L. Special castings are available
in low-ferrite stainless steel or high-performance alloys such as Hastelloy® and
AL-6XN®. Class VI elastomers are standard for pharmaceutical applications.

Electropolishing and enhanced internal surface finishes to 15 Ra are available


on most products.

Casing drain and mounting options provide complete drainability critical for
long-term system cleanliness. Pumps can be easily configured for steam-in-
place sterilization, with no external cooling devices required.

Water For Injection (WFI) Pumps


Fristam is the industry leader for WFI and other high-purity service. Fristam
WFI centrifugal pumps are a precision adaptation of our FP, FPX, and FPR
pumps. They feature an advanced seal design that protects product sterility,
saves valuable product and provides for long seal life.

Fristam pioneered a pressurized double seal flush system that ensures product
sterility and saves valuable product by maintaining positive pressure in the
critical seal area. The internal seal design provides extra cooling and lubrication
on the front seal face to significantly extend seal life and provide for more
system uptime.

Numerous seal and piping configurations, including single seal piping, are
available to meet your processing requirements.

Comprehensive
Documentation Options
Certified Drawings
Mill Certification
Physical Certifications
Material Verification
Certificate of Conformance
Certified Finish
Passivation Certificate
Certified Welding
Hydrostatic Test
Short Run Test
Performance Test
NPSH Test
Witness Test
Vibration Test
Noise Test

13
FP/FPX/FPR Performance Curves
Models: 1750 RPM­(Composite “A”)
Maximum Flow: 400 GPM
OF HEAD
METERS

FT. OF
HEAD

125

30 100

75
751
20 1741

50

741

10 3451

25 3541
731
721
711 3531
3521
0 701
0
0 50 100 150 200 250 300 350 400 GPM

0 20 40 60 80 M3/HR

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
14
FP/FPX/FPR Performance Curves
Models: 1750 RPM­(Composite “B”)
Maximum Flow: 2000 GPM
OF HEAD
METERS

FT. OF
HEAD

60 200

175
50

150
4001-X
40
125
1161

4001
30 100
1151

75
20

50

10
25 3551

1051
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 GPM

0 50 100 150 200 250 300 350 400 450 M3/HR

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
15
FP/FPX/FPR Performance Curves
Model: 701­ (1750 RPM, Inlet 1.5”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

20
6

18

5 IMPELLER DIAMETE
16 R
100

95
14
4 90

12 85

80
3 10
¹⁄3 hp
75
¼ hp
8
HE
AD
CA
PA

2
C
ITY

4
1

2 NPSH REQUIRED 10 NPSH IN FEET

0 0 0

GPM 0 4 8 12 16 20 24 28 32 36 40

M3/HR. 0 1 2 3 4 5 6 7 8

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
16
FP/FPX/FPR Performance Curves
Model: 711­ (1750 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

30
IMPELLER DIAME
130 TER

125
8
120 ½ hp
25
115
¼ hp
110

HE
AD
105
20

CA
6

PA
100

CIT
Y
¾ hp

15

10 10

5 5

NPSH IN FEET
NPSH REQUIRED

0 0 0
GPM 0 10 20 30 40 50 60

M3/HR. 0 2 4 6 8 10 12

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
17
FP/FPX/FPR Performance Curves
Model: 721­ (1750 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

40
12
IMPELLER D
145 IAMETER

35 140

10 135

¾ hp
130
30
125
½ hp
8

HE
120 1 hp

AD
25

CA
PA
115

CI
TY
110

6 20

15
4

10

2
5 5
NPSH IN FEET

NPSH REQUIRED
0 0 0
GPM 0 10 20 30 40 50 60 70 80

M3/HR. 0 3 6 9 12 15 18

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
18
FP/FPX/FPR Performance Curves
Model: 3521­ (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

40
12

IMPELLER DIAMETER
145
35
140
10

1½ hp
30 135

HE
AD
130
8

CA
1 hp

PA
25

CI
TY
125
¾ hp

120
6 20
½ hp

115

15
4

10

2
5 10
NPSH IN FEET

NPSH REQUIRED

0 0 0
GPM 0 25 50 75 100 125 150 175 200

M3/HR. 0 5 10 15 20 25 30 35 40 45

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
19
FP/FPX/FPR Performance Curves
Model: 731­ (1750 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

50
15
IMPELLE
175 R DIAM
ETER
170

165 ¾ hp
160
½ hp
155
40
12 150

1 hp

30

HE
9

AD
CA
PA
1½ hp

CI
TY
6 20

3 10 10

5 NPSH IN FEET

NPSH REQUIRED

0 0 0
GPM 0 20 40 60 80 100

M3/HR. 0 5 10 15 20

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
20
FP/FPX/FPR Performance Curves
Model: 3531­ (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

55
175 IMPELLER
DIAME
TER
170
15 50
165

45 3 hp
160

155
2 hp
40
150

145 1½ hp
35

HE
AD
10 140

CA
PA
135

CIT
30 1 hp

Y
130

25

20

5
15

10 20

NPSH IN FEET
5 10

NPSH REQUIRED
0 0 0
GPM 0 25 50 75 100 125 150 175 200 225 250 275

M3/HR. 0 10 20 30 40 50 60

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
21
FP/FPX/FPR Performance Curves
Model: 741­ (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

70
IMPELLER DIAMETE
205 R
20 200
1½ hp 2 hp
195
190
60 1 hp
185
180
175
170
165
50
15

HE
AD
3 hp

CA
PA
CIT
Y
40

10
30

20

10 10
NPSH IN FEET
5
NPSH REQUIRED

0 0 0
GPM 0 20 40 60 80 100 120 140

M3/HR. 0 5 10 15 20 25 30

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
22
FP/FPX/FPR Performance Curves
Model: 1741­ (1750 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

90

25
80 IMPELLER DIAMETER
205

200
HEA
195 DC
70 2 hp APA
190 CIT
Y
20 185 5 hp
1½ hp 3 hp
180
60 175
170
165

15 50

40

10
30

20 10
5

10 5 NPSH IN FEET
NPSH REQUIRED

0 0 0
GPM 0 20 40 60 80 100 120 140 160 180

M3/HR. 0 10 15 20 25 30 35 40

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
23
FP/FPX/FPR Performance Curves
Model: 3541­ (1750 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD

OF HEAD
METERS

FEET

80

IMPELLER DIAMETER
70 205

20 200

195
60
190

185
180 3 hp
50

HE
15 175 5 hp

AD
CA
170 7 hp

PA
CI
165

TY
160
40 155

150
10
30

20 20
5

10 10

NPSH REQUIRED NPSH IN FEET

0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500

M3/HR. 0 10 20 30 40 50 60 70 80 90 100 110

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
24
FPR Performance Curves
Model: 751­ (1750 RPM, Inlet 3”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

110
IMPELLER DIAMETER
250
100 50
30 245
HE
AD
240 CA
90 PA
C ITY
235 5 hp
3 hp

80 230 40
225
220 7½ hp
215
70
210
20 205
200
60 30

50

40 20

10
30

20 10

NPSH REQUIRED
10 NPSH IN FEET

0 0 0

GPM 0 20 40 60 80 100 120 140 160

M3/HR. 0 5 10 15 20 25 30 35

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
25
FP/FPX/FPR Performance Curves
Model: 3451­ (1750 RPM, Inlet 3”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

120
35

100
30
IMPELLER DIAMET
250 ER
245
240
25 235 5 hp
80
230
225
220 HE
AD
3 hp CA
20 215 PA
CI
210 TY
60 2 hp
205 7½ hp
200
15 195

40

10

20 20
5
NPSH IN FEET
10
NPSH REQUIRED

0 0 0
GPM 0 50 100 150 200 250 300

M3/HR. 0 10 20 30 40 50 60

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
26
FP/FPX/FPR Performance Curves
Model: 3551­ (1750 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD

OF HEAD
METERS

FEET

130

120
35
110 IMPELLER DIAMET
250 ER
245
100 240
30
235
230
90 10 hp 15 hp
225
220 7½ hp HE
25 5 hp A
80 215

D
CA
210

PA
CIT
205
70

Y
200
20 195
60

15 50

40

10
30

20 40
5
NPSH IN FEET
10 20
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650

M3/HR. 0 20 40 60 80 100 120 140 160 180 200

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
27
FP/FPX/FPR Performance Curves
Model: 1051­ (1750 RPM, Inlet 4”, Outlet 4”)
OF HEAD

OF HEAD
METERS

FEET

120

35
280 IMPELLE
R DIAM
ETER
275

100 270
30
265

260

255
25 80 250

245
20 hp
240

20 15 hp
HE
60 10 hp AD
CA
PA
7½ hp CIT
Y
15

40

10

20 20
5
NPSH IN FEET
10

NPSH REQUIRED
0 0 0
GPM 0 150 300 450 600 750 900

M3/HR. 0 25 50 75 100 125 150 175 200

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
28
FP/FPX Performance Curves
Model: 1151­ (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
OF HEAD

OF HEAD
METERS

FEET

200
60

175

50

150

R DIAMETER
IMPELLE
40
280
125
275
270
HEA
DC
APA
265 10 HP 15 HP 20 HP CIT
260 25 HP Y
255 30 HP
30 100 250
245
240

75
20

50 20

10
25 10
NPSH IN FEET

NPSH REQUIRED
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000

M3/HR. 0 20 40 60 80 100 1200 140 160 180 200 220

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
29
FP/FPX Performance Curves
Model: 1161­ (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
OF HEAD

OF HEAD
METERS

FEET

200
60

320
175
315

50 310
305
300
150 295

290
285 IMPELLER DIAMETER
40
280
125 15 HP
275 HEAD
20 HP CAP
270 ACIT
25 HP Y
265 10 HP
260
255
30 100 250 30 HP
245
240

75
20

50 20

10
25 10
NPSH IN FEET

NPSH REQUIRED
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000

M3/HR. 0 20 40 60 80 100 1200 140 160 180 200 220

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
30
FPR Performance Curves
Model: 1161­ (1750 RPM, Inlet 4”, Outlet 4”)
FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
OF HEAD

OF HEAD
METERS

FEET

200
60

IMPELLER DIAMETER
320
175
315

50 310
HEA
305 D CAP
300 ACI
TY
150 295 25 HP 50 HP

290
20 HP 40 HP
285
40
280
125 15 HP 30 HP
275
270
265 10 HP
260
255
30 100 250
245
240

75
20

50 20

10
25 10
NPSH IN FEET

NPSH REQUIRED
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000

M3/HR. 0 20 40 60 80 100 1200 140 160 180 200 220

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
31
FPR Performance Curves
Model: 4001­ (1750 RPM, Inlet 6”, Outlet 4”)
OF HEAD

OF HEAD
METERS

FEET

60 200

IMPELLER DIAMETER
180 360

HEA
350 D CA
PAC
50 ITY
160 340

330

140 75 hp
320
40
50 hp 60 hp
310 30 hp 40 hp
120
300

290
30 100
280

80

20
60

40 20
10

UIRED
NPSH REQ

NPSH IN FEET
20 10

0 0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800 2000

M3/HR. 0 50 100 150 200 250 300 350 400 450

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
32
FPR Performance Curves
Model: 4001­-X (1750 RPM, Inlet 6”, Outlet 4”)
OF HEAD

OF HEAD
METERS

FEET

60 200
50 hp
75 hp

180

50
160
100
hp

140
40

120

30 100

80

20
60

40 20
10

UIRED
NPSH REQ

NPSH IN FEET
20 10

0 0 0
GPM 0 200 400 600 800 1000 1200 1400 1600 1800 2000

M3/HR. 0 50 100 150 200 250 300 350 400 450

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
33
FP/FPX/FPR Performance Curves
Models: 3500 RPM­(Composite “A”)
Maximum Flow: 800 GPM
OF HEAD
METERS

FT. OF
HEAD

450

420
120 390

360

100 330
3552
752
300

80 270

240

210
60 1742
180
742
150
40 1732 3532 3452
120
732
722
90
3542
20 3522
60
712
30
702
0 0
0 50 100 150 200 300 400 500 500 700 800 GPM

0 50 100 150 200 M3/HR

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
34
FP/FPX/FPR Performance Curves
Models: 3500 RPM­(Composite “B”)
Maximum Flow: 1700 GPM
OF HEAD
METERS

FT. OF
HEAD

500

140
450

120 400

350
100
3552 4”
300
3652
80
250

60 200

3642
150
40

100

20
50

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 GPM

0 50 100 150 200 250 300 350 400 M3/HR

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
35
FP/FPX/FPR Performance Curves
Model: 702­ (3500 RPM, Inlet 1.5”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

90

25

75

20 IMPELLER
100 DIAMETE
R
60
95

90
15
85
45
¾ hp 1½ hp
½ hp 1 hp HE
80 AD
C
AP
AC
10 75
IT
Y
30

5
15

6 NPSH IN FEET
4
NPSH REQUIRED
2
0 0 0
GPM 0 10 20 30 40 50 60

M3/HR. 0 2 4 6 8 10 12

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
36
FP/FPX/FPR Performance Curves
Model: 712­ (3500 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

120
35

130mm IMPELLER
130 DIAMETER
5 1/4"
100
30 125 3 hp

120
2 hp
25 115
80

110

HE
AD
20

CA
PA
60

CIT
5 hp

Y
15

40

10

20 10
5
NPSH IN FEET
IRED
NPSH REQU

0 0 0
GPM 0 20 40 60 80 100 120

M3/HR. 0 5 10 15 20 25

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
37
FP/FPX/FPR Performance Curves
Model: 722­ (3500 RPM, Inlet 2”, Outlet 1.5”)
OF HEAD

OF HEAD
METERS

FEET

150
45
IMPELLER DIAMETER
145

40 140

120 135
35 5 hp HE
A
130

D
CA
PA
CIT
125 3 hp

Y
30 2 hp 7½ hp
120
90

25 115

110

20
60

15

10
30

10
5 NPSH IN FEET

NPSH REQUIRED

0 0 0
GPM 0 30 60 90 120 150

M3/HR. 0 5 10 15 20 25 30

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
38
FP/FPX/FPR Performance Curves
Model: 3522­ (3500 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

160

IMPELLER DIAME
145 TER
45
140
140

40 10 hp
135
120
7½ hp
35 130

HE
AD
CA
PA
100 125
30

CIT
5 hp

Y
120

25 15 hp
80
115 3 hp

20
60

15

40
10

20 40
5 NPSH IN FEET
20
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400

M3/HR. 0 10 20 30 40 50 60 70 80 90

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
39
FP/FPX Performance Curves
Model: 732­ (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
OF HEAD

OF HEAD
METERS

FEET

200
60

165 IMPELLER
DIAMETE
175 R
160
50
155

150 150 HEA


10 hp DC
AP
AC
145 ITY
40 7½ hp
140
125
135
5 hp
130

30 100
125

120
3 hp
75
20

50 10

10
25 5
NPSH IN FEET
QUIR ED
NPSH RE

0 0 0
GPM 0 25 50 75 100 125 150 175 200

M3/HR. 0 5 10 15 20 25 30 35 40 45

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
40
FP/FPX Performance Curves
Model: 1732­ (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
OF HEAD

OF HEAD
METERS

FEET

225

R DIAMETER
200 IMPELLE
60 165

160 7½ hp
175
155 HE
10 hp 15 hp AD
50 CA
PA
150
CIT
Y
150
20 hp
145

40 140
125

30 100

75
20
30
50

10
15
25 NPSH IN FEET

NPSH REQUIRED

0 0 0
GPM 0 75 150 225 325 375

M3/HR. 0 10 20 30 40 50 60 70 80

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
41
FP/FPX/FPR Performance Curves
Model: 3532­ (3500 RPM, Inlet 2.5”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

225
175
IMPELLER DIAMETER

170
200
60
165
HE
160 AD
175 CA
PA
CI
155 TY
50
150 20 hp 25 hp
150
145

40 140 15 hp
125
135 7½ hp 30 hp
5 hp
130 10 hp

30 100

75
20

50 50

10
25 25 NPSH IN FEET

NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450

M3/HR. 0 20 40 60 80 100

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
42
FP/FPX Performance Curves
Model: 742­ (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
OF HEAD

OF HEAD
METERS

FEET

300

80 205
IMPELLER DIAM
ETER
250 200
195
HEA
D CA
190 PAC
ITY
185 7½ hp

180 10 hp 15 hp
175
60 200
170
20 hp

150

40

100

20

50 10
NPSH IN FEET

IRED
NPSH REQU
0 0 0

GPM 0 25 50 75 100 125 150 175 200

M3/HR. 0 10 20 30 40

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
43
FPR Performance Curves
Model: 742­ (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 742 covers the range of both the FP/FPX 732 and 742
OF HEAD

OF HEAD
METERS

FEET

300

80 205
IMPELLER DIAM
ETER
250 200
195
HEA
D CA
190 PAC
ITY
185
180 15 hp
175 10 hp
60 200
170
20 hp
165
7½hp
160

155
150 150
5 hp
145
40
140

135

130 3 hp
100
125
120

20

50 10
NPSH IN FEET

IRED
NPSH REQU
0 0 0

GPM 0 25 50 75 100 125 150 175 200

M3/HR. 0 10 20 30 40

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
44
FP/FPX Performance Curves
Model: 1742­ (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
OF HEAD

OF HEAD
METERS

FEET

350

100

IMPELLER DIAMETER
205
300
200
195
80 190
250 185 25 hp HE
15 hp 20 hp 30 hp AD
CA
180 40 hp PA
10 hp CI
TY
175

200 170
60

50 hp

150

40

100

20
50 20
NPSH IN FEET
10
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500

M3/HR. 0 20 40 60 80 100

CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
45
FPR Performance Curves
Model: 1742­ (3500 RPM, Inlet 2.5”, Outlet 2”)
FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
OF HEAD

OF HEAD
METERS

FEET

350

100

IMPELLER DIAMETER
205
300
200
195
80 190
250 185 25 hp HE
30 hp AD
CA
180 40 hp PA
20 hp CI
TY
175
15 hp
200 170
60
165 10 hp
160
50 hp
155
150 7½ hp
150
145
40 140

100

20
50 20
NPSH IN FEET
10
NPSH REQUIRED
0 0 0
GPM 0 50 100 150 200 250 300 350 400 450 500

M3/HR. 0 20 40 60 80 100

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
46
FP/FPX/FPR Performance Curves
Model: 3542­ (3500 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD

OF HEAD
METERS

FEET

90 300

IMPELLER DIAMETER
205

80 200

250
195 30 hp
70 190
25 hp
185 20 hp

HE
AD
180
200

CA
60

PA
175

CI
TY
170 15 hp
40 hp
165 50 hp
50
160 10 hp
150 155

40 150

30 100

20

50
25
10 NPSH IN FEET

IR ED
NPSH REQU

0 0 0
GPM 0 100 200 300 400 500 600 700 800 900

M3/HR. 0 20 40 60 80 100 120 140 160 180 200

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
47
FPR Performance Curves
Model: 752­ (3500 RPM, Inlet 3”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

500 100
150

IMPELLER DIAMET
450 250 ER 90
250

125
400 250 HE 80
AD
250
CA
PA
CI
T
250 50 hp Y
350 250 40 hp 70
100 250
250
250
30 hp
300 60
250 15 hp 20 hp 25 hp
250

75 250 50

200 40

50
150 30

100 20
25
ED
NPSH REQUIR
50 10 NPSH IN FEET

0 0 0

GPM 0 50 100 150 200 250 300 350

M3/HR. 0 10 20 30 40 50 60 70 80

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
48
FP/FPX/FPR Performance Curves
Model: 3452­ (3500 RPM, Inlet 3”, Outlet 2”)
OF HEAD

OF HEAD
METERS

FEET

120 400
250 IMP
ELL
ER D
245 IAM
ETE
240 R
350
235
100
230

225
300
220 40 hp
215 30 hp
80
HE
AD
210
250
CA
25 hp
PA
205
CIT
Y

200 20 hp
50 hp
15 hp
60 200 195

60 hp

150
40

100

20
50
NPSH IN FEET

20
D
NPSH REQUIRE
0 0 0
GPM 0 100 200 300 400 500 600 700 800

M3/HR. 0 20 40 60 80 100 120 140 160 180

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
49
FP/FPX/FPR Performance Curves
Model: 3552­ (3500 RPM, Inlet 3”, Outlet 2.5”)
OF HEAD

OF HEAD
METERS

FEET

500
140

450
IMPELLER DIAMETER
250
HEAD
120 245 CAPA
CITY
400 240
235 100 hp
230
75 hp
100 350 225
220 60 hp
215
50 hp
300 210 40 hp
25 hp 30 hp
205
80
200
250 195

60 200

150
40

100 50

20
50 25 NPSH IN FEET

NPSH REQUIRED

0 0 0
GPM 0 75 150 225 300 375 450 525 600 675 750

M3/HR. 0 15 30 45 60 75 90 105 120 135 150

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
50
FP/FPX/FPR Performance Curves
Model: 3552-4”­ (3500 RPM, Inlet 4”, Outlet 2.5”)
OF HEAD

OF HEAD
METERS

FEET

500
140

450

250
120
400

240

100 350
230

220
300
100 hp
210
80 75 hp
30 hp 60 hp
250 200
25 hp 50 hp
190 40 hp

60 200

150
40

100 50

20
50 25 NPSH IN FEET

E QUIRED
NPSH R
0 0 0
GPM 0 100 200 300 400 500 600 700 800 900 1000

M3/HR. 0 25 50 75 100 125 150 105 175 200 225

CAPACITY

Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
51
FPR Performance Curves
Model: 3642­ (3500 RPM, Inlet 4”, Outlet 4”)
OF HEAD

OF HEAD
METERS

FEET

90 300

ETER
LER DIAM
IMPEL
80 220

250 HEA
DC
APA
CIT
Y
70 210
75 hp
100 hp

60 200 200
60 hp
50 hp
190 40 hp
50

150 180

40 170

30 100

20

50

10

0 0

GPM 0 200 400 600 800 1000 1200 1400 1600 1800

M3/HR. 0 50 100 150 200 250 300 350 400

CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
52
FPR Performance Curves
Model: 3652­ (3500 RPM, Inlet 4”, Outlet 2.5”)
OF HEAD

OF HEAD
METERS

FEET

500
140
IMPELLER DIAMETER
450 250

120
HE
400 240 AD
CA
PA
230 CIT
Y

100 350 220

150 hp
50 hp
210
300 40 hp 125 hp
60 hp 75 hp
80 200 100 hp

250

60 200

150
40

100

20
50

0 0

GPM 0 200 400 600 800 1000 1200 1400

M3/HR. 0 30 60 90 120 150 180 210 240 270 300

CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures.
Actual performance may vary by application product. Please contact Fristam for different conditions.
53
FP Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

D
H B OUTLET
C
198
J (7.80")

ØK
ØG
INLET
180
(7.09")

210
98 (8.27")
(3.88")
180 ADJ. LEGS
36(1.42") X 16(.63") SLOT (7.09") F
(4 PLACES) (OPTIONAL)
356 38 (1.50")
(14.00") E MAX. ADJ.
203
(8.00")

1265000384 REV-

DIMENSIONS IN MILLIMETERS (INCHES) DIMENSIONS IN


PUMP MODEL INLET OUTLET MOTOR HP MOTOR MILLIMETERS (INCHES)
A B C D E F ØG
FRAME
108 44.5 108.5 146.5 154.5 186.5 150 1750 RPM 3500 RPM H J ØK
FP 701 / 702 1.5" 1.5" (4.25") (1.75") (4.27") (5.77") (6.08") (7.34") (5.90") 115 236 157
0.5 HP 56C (4.53") (9.29") (6.19")
144 58 113 150 158 190 185
FP 711 / 712 2" 1.5" (5.67") (2.28") (4.45") (5.90") (6.22") (7.48") (7.28") 115 236 157
0.75 HP 0.75 HP 56C (4.53") (9.29") (6.19")
170 79 113 150 158 190 230
FP 721 / 731 / 722 2" 1.5" (6.69") (3.11") (4.45") (5.90") (6.22") (7.48") (9.06") 115 236 157
1 HP 56C (4.53") (9.29") (6.19")
195 96 101 141 149 181 270
FP 741 / 732 / 742 2.5" 2" (7.68") (3.78") (3.98") (5.55") (5.87") (7.13") (10.63") 115 252 157
1 HP 1.5 HP 143TC (4.53") (9.94") (6.19")
FP 1741 / 1732 / 200 91 104 150.5 158.5 190.5 270
2.5" 2" (7.87") (3.58") (4.09") (5.93") (6.24") (7.50") (10.63")
1742 133 259 183
1.5 HP 145TC (5.22") (10.19") (7.19")
190 80 118 162 170 202 230
FP 3521 / 3522 2.5" 2" (7.48") (3.15") (4.64") (6.38") (6.69") (7.95") (9.06") 133 284 183
2 HP 2 HP 145TC (5.22") (11.19") (7.19")
191 95 115.5 162 170 202 260
FP 3531 / 3532 2.5" 2" (7.52") (3.74") (4.55") (6.38") (6.69") (7.95") (10.24") 133 284 183
3 HP 145TC (5.22") (11.19") (7.19")
211 115 118 162 170 202 290
FP 3541 / 3542 3" 2.5" (8.31") (4.53") (4.64") (6.38") (6.69") (7.95") (11.42") 133 313 216
3 HP 182TC (5.23") (12.31") (8.50")
211 140 114 158 166 198 350
FP 3451 / 3452 3" 2" (8.31") (5.51") (4.49") (6.22") (6.54") (7.80") (13.78") 152 348 216
5 HP 5 HP 184TC (6.00") (13.68") (8.50")
152 386 216
7.5 HP 184TC (6.00") (15.18") (8.50")
189 388 263
7.5 HP 7.5 HP 213TC (7.46") (15.27") (10.34")
189 388 263
10 HP 215TC (7.46") (15.27") (10.34")
189 416 263
10 HP 15 HP 215TC (7.46") (16.40") (10.34")
1265000385 REV-

54
FP Double Flange Dimensional Drawing [Frame Sizes 182TC–286T(S)C]
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

J L D
H B OUTLET
C

INLET A
BALDOR

ØK

250 ØE
(9.84")

290
M (11.42")

ADJ. BASE
300 (OPTIONAL)
19(.75") X 35(1.38") SLOT (11.81") F N
(4 PLACES) 559 300
(22.00") E (11.81")

1265000386 REV-

DIMENSIONS IN MILLIMETERS (INCHES) MOTOR HP MOTOR DIMENSIONS IN MILLIMETERS (INCHES)


PUMP MODEL INLET OUTLET
A B C D E F ØE 1750 RPM 3500 RPM FRAME H J ØK L M N
250 170 167 202.5 254 317.5 406 133 313 216 200 117 44.5
FP 1051 4" 4" (9.84") (6.69") (6.57") (7.97") (10.00") (12.50") (15.98") * 3 HP 182TC (5.23") (12.31") (8.50") (7.87") (4.62") (1.75")
250 170 110.5 146 197.5 261 406 189 388 263 200 117 44.5
FP 1151 4" 4" (9.84") (6.69") (4.35") (5.75") (7.78") (10.28") (15.98") * 5 HP 213TC (7.46") (15.27") (10.34") (7.87") (4.62") (1.75")
250 170 110.5 146 197.5 261 406 189 388 263 200 117 44.5
FP 1161 4" 4" (9.84") (6.69") (4.35") (5.75") (7.78") (10.28") (15.98") **7.5 HP 213TC (7.46") (15.27") (10.34") (7.87") (4.62") (1.75")
250 170 111 146 197.5 261 406 189 416 263 200 117 44.5
FP 1161 6" 4" (9.84") (6.69") (4.37") (5.75") (7.78") (10.28") (15.98") ** 10 HP 215TC (7.46") (16.40") (10.34") (7.87") (4.62") (1.75")
195 96 101 143.5 195 258.5 270 220 415 263 200 98*** 38****
FP 742 2.5" 2" (7.68") (3.78") (3.98") (5.65") (7.68") (10.18") (10.63") 15 HP 254TC (8.67") (16.33") (10.34") (7.87") (3.88") (1.50")
200 91 104 153 204.5 268 270 239 499 336 200 98*** 38****
FP 1732 / 1742 2.5" 2" (7.87") (3.58") (4.09") (6.02") (8.05") (10.55") (10.63") 20 HP 256TC (9.42") (19.66") (13.25") (7.87") (3.88") (1.50")
191 95 115.5 164.5 216 279.5 260 225 491 263 200 98 38
FP 3532 2.5" 2" (7.52") (3.74") (4.55") (6.48") (8.50") (11.00") (10.24") 20 HP 256TC (8.88") (19.34") (10.34") (7.87") (3.88") (1.50")
211 115 118 164.5 216 279.5 290 333 588 395 200 117 44.5
FP 3542 3" 2.5" 25 HP 284TC
(8.31") (4.53") (4.64") (6.48") (8.50") (11.00") (11.42") (13.12") (23.13") (15.56") (7.87") (4.62") (1.75")
211 140 114 160.5 212 275.5 350 333 588 395 200 98 38
FP 3452 3" 2" (8.31") (5.51") (4.49") (6.32") (8.35") (10.85") (13.78") 25 HP 284TSC (13.12") (23.13") (15.56") (7.87") (3.88") (1.50")
231 140 119 170.5 222 285.5 350 333 588 395 200 117 44.5
FP 3551 / 3552 3" 2.5" (9.09") (5.51") (4.68") (6.71") (8.74") (11.24") (13.78") 30 HP 286TC (13.12") (23.13") (15.56") (7.87") (4.62") (1.75")
333 588 395 200 98 38
30 HP 286TSC (13.12") (23.13") (15.56") (7.87") (3.88") (1.50")

* 3551 ONLY 1265000387 REV A


** 3551, 1051 & 1151 ONLY
*** 117 (4.62") FOR 1051, 1151 & 1161
**** 44.5 (1.75") FOR 1051, 1151 & 1161

55
FP Double Flange Dimensional Drawing [Frame Sizes 324T(S)C–365T(S)C]
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

H Q D
C L B OUTLET

INLET A
BALDOR

ØJ

K ØE

117.5
ØR (4.62")
ADJ. LEGS
(OPTIONAL)
M P 44.5 (1.75") N il-0661
S MAX. ADJ.

DIMENSIONS IN MILLIMETERS (INCHES) MOTOR HP MOTOR DIMENSIONS IN MILLIMETERS (INCHES)


PUMP MODEL INLET OUTLET
A B C D ØE 1750 RPM 3500 RPM FRAME H ØJ K L M N P Q ØR S
250 170 167 202.5 406 636 413 203 371 267 318 133 216 16.7 470
FP 1051 4" 4" (9.84") (6.69") (6.57") (7.97") (15.98") 40 HP 324TSC (25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
250 170 110.5 146 406 636 413 203 371 267 318 133 216 16.7 470
FP 1151 4" 4" (9.84") (6.69") (4.35") (5.75") (15.98") 40 HP 324TSC (25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
250 170 110.5 146 406 636 413 203 371 305 318 133 216 16.7 470
FP 1161 4" 4" (9.84") (6.69") (4.35") (5.75") (15.98") 50 HP 326TSC (25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")
250 170 111 146 406 636 413 203 371 305 318 133 216 16.7 470
FP 1161 6" 4" (9.84") (6.69") (4.37") (5.75") (15.98") 50 HP 326TSC (25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")
200 91 104 153 270 702 485 229 457 285 355 149 232 17.5 508
FP 1742 2.5" 2" (7.87") (3.58") (4.09") (6.02") (10.63") 60 HP 364TSC (27.60") (19.11") (9.00") (18.00") (11.25") (14.00") (5.87") (9.13") (11/16") (20.00")
211 115 118 164.5 290 702 485 229 457 285 355 149 232 17.5 508
FP 3542 3" 2.5" (8.31") (4.53") (4.64") (6.48") (11.42") 60 HP 364TSC (27.60") (19.11") (9.00") (18.00") (11.25") (14.00") (5.87") (9.13") (11/16") (20.00")
211 140 114 160.5 350 702 485 229 457 311 355 149 232 17.5 508
FP 3452 3" 2" (8.31") (5.51") (4.49") (6.32") (13.78") 75 HP 365TSC (27.60") (19.11") (9.00") (18.00") (12.25") (14.00") (5.87") (9.13") (11/16") (20.00")
231 140 119 170.5 350 702 485 229 457 311 355 149 232 17.5 508
FP 3551 / 3552 3" 2.5" (9.09") (5.51") (4.68") (6.71") (13.78") 75 HP 365TSC (27.60") (19.11") (9.00") (18.00") (12.25") (14.00") (5.87") (9.13") (11/16") (20.00")

1265000715 REV-

56
FPX Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

F N D
C J B
OUTLET

A
ØE
ØG
H
INLET
98 ADJ. LEGS
ØP (3.88") (OPTIONAL)

K M
38 (1.50")
Q MAX. ADJ. L il-0657

DIMENSIONS IN MILLIMETERS (INCHES) MOTOR HP MOTOR DIMENSIONS IN MILLIMETERS (INCHES)


PUMP MODEL INLET OUTLET
A B C D ØE 1750 RPM 3500 RPM FRAME F ØG H J K L M N ØP Q
108 44.5 108.5 146.5 150 281 183 89 133 102 140 70 120 8.7 356
FPX 701 / 702 1.5" 1.5" (4.25") (1.75") (4.27") (5.77") (5.90") 1 HP 1.5 HP 143TC (11.06") (7.19") (3.50") (5.22") (4.00") (5.50") (2.75") (4.72") (11/32") (14.00")
144 58 113 150 185 281 183 89 133 102 140 70 120 8.7 356
FPX 711 / 712 2" 1.5" (5.67") (2.28") (4.45") (5.90") (7.28") 1.5 HP 145TC (11.06") (7.19") (3.50") (5.22") (4.00") (5.50") (2.75") (4.72") (11/32") (14.00")
170 79 113 150 230 281 183 89 133 102 140 70 120 8.7 356
FPX 721 / 731 / 722 2" 1.5" (6.69") (3.11") (4.45") (5.90") (9.06") 2 HP 2 HP 145TC (11.06") (7.19") (3.50") (5.22") (4.00") (5.50") (2.75") (4.72") (11/32") (14.00")
195 96 101 141 270 313 183 114 132 140 191 89 140 10.3 356
FPX 741 / 732 / 742 2.5" 2" (7.68") (3.78") (3.98") (5.55") (10.63") 3 HP 182TC (12.31") (7.19") (4.50") (5.21") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
200 91 104 150.5 270 348 183 114 132 140 191 89 140 10.3 356
FPX 1741 / 1732 / 1742 2.5" 2" (7.87") (3.58") (4.09") (5.93") (10.63") 3 HP 182TC (13.69") (7.19") (4.50") (5.21") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
190 80 118 162 230 347 216 114 152 140 191 89 140 10.3 356
FPX 3521 / 3522 2.5" 2" (7.48") (3.15") (4.64") (6.38") (9.06") 5 HP 184TC (13.68") (8.50") (4.50") (5.97") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
191 95 115.5 162 260 386 216 114 152 140 191 89 140 10.3 356
FPX 3531 / 3532 2.5" 2" (7.52") (3.74") (4.55") (6.38") (10.24") 5 HP 184TC (15.18") (8.50") (4.50") (5.97") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
211 115 118 162 290 386 216 114 152 140 191 89 140 10.3 356
FPX 3541 / 3542 3" 2.5" (8.31") (4.53") (4.64") (6.38") (11.42") 7.5 HP 184TC (15.18") (8.50") (4.50") (5.97") (5.50") (7.50") (3.50") (5.53") (13/32") (14.00")
211 140 114 158 350 388 263 133 189 140 216 108 140 10.3 356
FPX 3451 / 3452 3" 2" (8.31") (5.51") (4.49") (6.22") (13.78") 7.5 HP 213TC (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (5.53") (13/32") (14.00")
231 140 119 168 350 388 263 133 189 140 216 108 140 10.3 356
FPX 3551 3" 2.5" (9.09") (5.51") (4.68") (6.61") (13.78") 10 HP 10 HP 215TC (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (5.53") (13/32") (14.00")
436 263 133 189 140 216 108 140 10.3 356
15 HP 215TC (17.15") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (5.53") (13/32") (14.00")
447 263 159 225 210 254 121 169 13.5 406
15 HP 254TC (17.59") (10.34") (6.25") (8.88") (8.25") (10.00") (4.75") (6.65") (17/32") (16.00")
491 263 159 225 254 254 121 169 13.5 406
20 HP 256TC (19.34") (10.34") (6.25") (8.88") (10.00") (10.00") (4.75") (6.65") (17/32") (16.00")
499 336 159 239 254 254 121 169 13.5 406
20 HP 256TC (19.66") (13.25") (6.25") (9.42") (10.00") (10.00") (4.75") (6.65") (17/32") (16.00")
1265000540

57
FPX Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

H Q D
C L B OUTLET

INLET A
BALDOR

ØJ

K ØE

117.5
ØR (4.62")
ADJ. LEGS
(OPTIONAL)
M P 44.5 (1.75") N il-0661
S MAX. ADJ.

MOTOR HP
PUMP MODEL INLET OUTLET DIMENSIONS IN MILLIMETERS (INCHES) MOTOR DIMENSIONS IN MILLIMETERS (INCHES)
A B C D ØE 1750 RPM 3500 RPM FRAME H ØJ K L M N P Q ØR S
250 170 167 202.5 406 388 263 133 189 140 216 108 200 10.3 470
FPX 1051 4" 4" 7.5 HP 213TC
(9.84") (6.69") (6.57") (7.97") (15.98") (15.27") (10.34") (5.25") (7.46") (5.50") (8.50") (4.25") (7.87") (13/32") (18.50")
250 170 110.5 146 406 416 263 133 189 178 216 108 200 10.3 470
FPX 1151 4" 4" 10 HP 215TC
(9.84") (6.69") (4.35") (5.75") (15.98") (16.40") (10.34") (5.25") (7.46") (7.00") (8.50") (4.25") (7.87") (13/32") (18.50")
250 170 110.5 146 406 447 270 159 226 210 254 121 200 13.5 444
FPX 1161 4" 4" 15 HP 254TC
(9.84") (6.69") (4.35") (5.75") (15.98") (17.59") (10.62") (6.25") (8.88") (8.25") (10.00") (4.75") (7.87") (17/32") (17.50")
250 170 111 146 406 499 320 159 239 254 254 121 200 13.5 470
FPX 1161 6" 4" 20 HP 256TC
(9.84") (6.69") (4.37") (5.75") (15.98") (19.66") (12.60") (6.25") (9.42") (10.00") (10.00") (4.75") (7.87") (17/32") (18.50")
200 91 104 153 270 588 367 178 333 241 279 121 200 13.5 444
FPX 1742 2.5" 2" 25 HP 284TC
(7.87") (3.58") (4.09") (6.02") (10.63") (23.13") (14.44") (7.00") (13.11") (9.50") (11.00") (4.75") (7.87") (17/32") (17.50")
191 95 115.5 164.5 260 588 367 178 333 241 279 121 200 13.5 444
FPX 3532 2.5" 2" 25 HP 284TSC
(7.52") (3.74") (4.55") (6.48") (10.24") (23.13") (14.44") (7.00") (13.11") (9.50") (11.00") (4.75") (7.87") (17/32") (17.50")
211 115 118 164.5 290 588 367 178 333 279 279 121 200 13.5 444
FPX 3542 3" 2.5" 30 HP 286TC
(8.31") (4.53") (4.64") (6.48") (11.42") (23.13") (14.44") (7.00") (13.11") (11.00") (11.00") (4.75") (7.87") (17/32") (17.50")
211 140 114 160.5 350 588 367 178 333 279 279 121 200 13.5 444
FPX 3452 3" 2" 30 HP 286TSC
(8.31") (5.51") (4.49") (6.32") (13.78") (23.13") (14.44") (7.00") (13.11") (11.00") (11.00") (4.75") (7.87") (17/32") (17.50")
231 140 119 170.5 350 636 413 203 371 267 318 133 216 16.7 470
FPX 3552 3" 2.5" 40 HP 324TC
(9.09") (5.51") (4.68") (6.71") (13.78") (25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 267 318 133 216 16.7 470
40 HP 324TSC
(25.00") (16.25") (8.00") (14.62") (10.50") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 305 318 133 216 16.7 470
50 HP 326TC
(25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")
636 413 203 371 305 318 133 216 16.7 470
50 HP 326TSC
(25.00") (16.25") (8.00") (14.62") (12.00") (12.50") (5.25") (8.50") (21/32") (18.50")

il-0660

58
FPR Single Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

P B
Outlet
L T D

A
Inlet

X
Ø V Adjustable Legs
(Optional) R
Z
Q S Y
W Max. Leg
Adjustment

1265000202 Rev A
MOTOR HP MOTOR
L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET A B C D E
1750 RPM 3500 RPM FRAME
284 175 89 133 101.6 140 127 120 8.7 356 98 38 57.2 108 44.5 106.5 139.5 150
1 HP 1.5 HP 143TC FPR 701/702 1.5" 1.5"
11.18" 6.89" 3.5" 5.25" 4" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 4.25" 1.75" 4.19" 5.49" 5.91"
284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 144 58 113 145 185
1.5 HP 145TC FPR 711/712 2" 1.5"
11.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 5.67" 2.28" 4.45" 5.71" 7.28"
284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 170 79 113 145 230
2 HP 2 HP 145TC FPR 721/731/722 2" 1.5"
11.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 6.69" 3.11" 4.45" 5.71" 9.06"
340 221 114 149 114 191 108 169 10.3 356 98 38 69.9 195 96 101 136 270
3 HP 182TC FPR 741/742 2.5" 2"
13.39" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.68" 3.78" 3.98" 5.35" 10.63"
354 221 114 149 114 191 108 169 10.3 356 98 38 69.9 200 91 104 145.5 270
3 HP 182TC FPR 1741/1742 2.5" 2"
13.94" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.87" 3.58" 4.09" 5.73" 10.63"
354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 190 80 118 157.5 230
5 HP 184TC FPR 3521/3522 2.5" 2"
13.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.48" 3.15" 4.65" 6.2" 9.06"
354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 191 95 115.5 157.5 260
5 HP 184TC FPR 3531/3532 2.5" 2"
13.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.52" 3.74" 4.55" 6.2" 10.24"
423 221 114 149 140 191 108 169 10.3 356 98 38 69.9 211 115 118 157.5 290
7.5 HP 184TC FPR 3541/3542 3" 2.5"
16.65" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 4.53" 4.65" 6.2" 11.42"
403 260 133 187 140 216 108 169 10.3 356 98 38 88.9
7.5 HP 213TC
15.87" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
403 260 133 187 178 216 108 169 10.3 356 98 38 88.9
10 HP 215TC
15.87" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
416 260 133 187 178 216 108 169 10.3 356 98 38 88.9
10 HP 215TC
16.38" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
515 260 133 187 178 216 108 169 10.3 356 98 38 88.9
15 HP 215TC
20.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
499 327 159 244 210 254 102 169 13.5 406 98 38 108.0
15 HP 254TC
19.65" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 169 13.5 406 98 38 108.0
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 169 13.5 406 98 38 108.0
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
588 371 178 333 241 279 121 179 13.5 445 118 45 120.7
25 HP 284TSC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 241 279 121 179 13.5 445 118 45 120.7
25 HP 284TC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 179 13.5 445 118 45 120.7
30 HP 286TSC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 179 13.5 445 118 45 120.7
30 HP 286TC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
636 419 203 359 267 318 121 179 16.7 470 118 45 133.4
40 HP 324TSC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 267 318 121 179 16.7 470 118 45 133.4
40 HP 324TC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 179 16.7 470 118 45 133.4
50 HP 326TSC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 179 16.7 470 118 45 133.4
50 HP 326TC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"

1265000463

59
FPR Double Flange Dimensional Drawing
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

L T D
P B
Z C Outlet

Ø E

Inlet
M

Adjustable Legs R X
Ø V
(Optional)

Q S
Y
W Max. Leg
Adjustment

1265000203 Rev C

MOTOR HP MOTOR
L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET A B C D E
1750 RPM 3500 RPM FRAME
313 221 114 149 114 191 108 160 10.3 356 98 38 69.9 205 145 99 142 379
3 HP 182TC FPR 751/752 3" 2"
12.32" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 8.07" 5.71" 3.9" 5.59" 14.92"
348 221 114 149 114 191 108 160 10.3 356 98 38 69.9 211 140 114 160.5 350
3 HP 182TC FPR 3451/3452 3" 2"
13.7" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 5.51" 4.49" 6.32" 13.78"
347 221 114 149 140 191 108 160 10.3 356 98 38 69.9 230 140 119 170 350
5 HP 184TC FPR 3551/3552 3" 2.5"
13.66" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.06" 5.51" 4.69" 6.69" 13.78"
386 221 114 149 140 191 108 160 10.3 356 98 38 69.9 250 170 167 202.5 406
5 HP 184TC FPR 1051 4" 4"
15.2" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.84" 6.69" 6.57" 7.97" 15.98"
386 221 114 149 140 191 108 160 10.3 356 98 38 69.9 250 170 110.5 146 406
7.5 HP 184TC FPR 1161 4" 4"
15.2" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 2.75" 9.84" 6.69" 4.35" 5.75" 15.98"
388 260 133 187 140 216 108 160 10.3 356 98 38 88.9
7.5 HP 213TC
15.28" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
388 260 133 187 178 216 108 160 10.3 356 98 38 88.9
10 HP 10 HP 215TC
15.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
436 260 133 187 178 216 108 160 10.3 356 98 38 88.9
15 HP 215TC
17.17" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"
447 327 159 244 210 254 102 160 13.5 406 98 38 108
15 HP 254TC
17.6" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
491 327 159 244 254 254 102 160 13.5 406 98 38 108
20 HP 256TC
19.33" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
499 327 159 244 254 254 102 160 13.5 406 98 38 108
20 HP 256TC
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"
588 371 178 333 241 279 121 174 13.5 445 118 45 121
25 HP 284TC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 241 279 121 174 13.5 445 118 45 121
25 HP 284TSC
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 174 13.5 445 118 45 121
30 HP 286TC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
588 371 178 333 279 279 121 174 13.5 445 118 45 121
30 HP 286TSC
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"
636 419 203 359 267 318 121 209 16.7 470 118 45 133
40 HP 324TC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 267 318 121 209 16.7 470 118 45 133
40 HP 324TSC
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 209 16.7 470 118 45 133
50 HP 326TC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
636 419 203 359 305 318 121 209 16.7 470 118 45 133
50 HP 326TSC
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"
685 470 229 383 286 356 89 209 16.7 508 127 45 149
60 HP 364TC
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 286 356 89 209 16.7 508 127 45 149
60 HP 364TSC
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 311 356 89 209 16.7 508 127 45 149
75 HP 365TC
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
685 470 229 383 311 356 89 209 16.7 508 127 45 149
75 HP 365TSC
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"

1265000463

60
FPR Double Flange Dimensional Drawing [Model 4001]
All pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.

232 239.5
A [9.13"] [9.43"] 228.5
127.8 D [9.00"]
4" SANITARY [5.03"]
CLAMP

300.5
[11.83"]

440
C [ 17.32"]
6" SANITARY
CLAMP

ADJUSTABLE LEGS
K (OPTIONAL)
E G
4X ØH

J
44.4 [1.75"]
MAX. ADJ. F

1265000053
8/19/02

MOTOR MOTOR
A B C D E F G ØH J K
HP FRAME
636 418 203 371 267 317 133 16.7 470 117
40 HP 324TC
25" 16.5" 8" 14.6" 10.5" 12.5" 5.2" 0.7" 18.5" 4.6"
636 418 203 371 305 317 133 16.7 470 117
50 HP 326TC
25" 16.5" 8" 14.6" 12" 12.5" 5.2" 0.7" 18.5" 4.6"
684 470 229 380 286 355 149 16.7 508 127
60 HP 364TC
26.9" 18.5" 9" 15" 11.3" 14" 5.9" 0.7" 20" 5"
684 470 229 380 311 355 149 16.7 508 127
75 HP 365TC
26.9" 18.5" 9" 15" 12.2" 14" 5.9" 0.7" 20" 5"
782 520 254 477 349 406 168 20.6 508 127
100 HP 405TC
30.8" 20.5" 10" 18.8" 13.7" 16" 6.6" 0.8" 20" 5"

1265000054
1/28/2008

61
CENTRIFUGAL POSITIVE DISPLACEMENT MIXING & BLENDING

Fristam Pumps USA Tel +1 800 841 5001


2410 Parview Road fristam@fristampumps.com Part #1050000103
Middleton, WI 53562-2524 www.fristam.com/usa ©2020 Fristam Pumps USA

You might also like