LETTER OF TRANSMITTAL To Khalid Awadh Alhamdi Factory (K.-MIX) Attention | Mr. Ahmed Ibrahim, Projects Manager Reference _| Plant Trial Mix Final Reports - TM # 9 (K-Mix Code : RC-09) Report Date | 03 June 2018 Job No. | SA15-9505 Royal Commission Infrastructure Projects, Yanbu Al-Sinaiyah Project: > Attached hereto are reports as follows: ; No. of Trial Mix/ Copies Description es Test Specimens FINAL REPORTS a Structural Microsilica Concrete : 30 MPa Grade (OPC+SF) 1 ; Testing of Hardened Concrete Compression Strength at 3, 7 & 28 days (ASTM C-39) (Lab. No. 6937) 12 I Chloride Permeability (AASHTO T-277-15 / ASTM C 4202-17) a 1 Chloride Content (BS 1881, Part-124) 3 Sulfate Content (BS 1881, Part-124) 3 1 Combind Aggregate Gradation of the Recommanded Mix Design 1 a Recommanded Mix Proportions 1 FUGRO-SUHAIMI LTD. Syed Arshadullah Branch Manager — Yanbu o @ xn e Conmeusssc Yanbu Al Sinaiyah - Saudi Arabia - Tel: 014 396-2173, Fax: 0143210963 Ear or 8 at MaterlsLab-VAN\Lab-2\Clcns-2018 KMIXiMix Design RC-Concrie Min Design-TML9-6937 daw Form # MAT 1.03, Issue #2 Rev.0 Apr. 2012 Sr Cen Awad Abu Factory (RMI) fuera Seunen Repro. Suisse Ses lw Dated: O3vone 2018 Page- 1 Scone IPA ST TABLE #9 PLANT TRIAL MIX No. TM #9 PLANT TRIAL MIX PRODUCED AT K-MIX— BATCHING PLANT NO 2, YANBU DATE PERFORMED : 04 APRIL 2018 MIX DESIGN ID. NO. (REFERENCE ) : FSL/ KM / 30 MPa (OPC+SF) CONCRETE GRADE ~ 30 MPa / K-MIX CODE : RC-09 RC CONCRETE CLASS DESIGNATION ~ Y30b (OPC+SE) CONCRETE TYPE ; STRUCTURAL MICROSILICA CONCRETE, MATERIALS SOURCE Coane Agwregse | any oO Ron Yantai Fine Aggregate (Natural Sand) Quarry near Yanbu Al-Nakhi Road Mixing Water Toe Water Potable Water Supply. Yanbu aa ‘Cement (Type T— OPC) ‘Yanku Cement Co, Liquid Admixture (MasterRheobuild563)__| Master Builders Co. (BASF) [Mise Admiss Dentiot Mistioy —| Admixture Densified Microsilica) | FeroPem, France] 1m SSD Propo: ms (Based on Actual Yield) CONSTITUENTS [st natch Weis Cement, (Type I, OPC) kg 380. 380 Densified Microsilica (Silica Fume) kg 35 35 Total Cementitious Material kg AIS 415 *Total Mixing Water, (Water + Ice) kg Ei 167 Free Water, (Water + Ice) kg 156 156 3/4" (19 mm) Aggregate kg 570 567 a | 1/2" (12.5 mm) Aggregate kg 285 284 3/8" (9.5 mm) Aggregate kg 285, 284 Fine Aggregate (Natural Sand) kg 730 724 Liquid Admixture (MasterRheobuild 563) liter 8.0 8.0 “*Free Water, (Water + Ice + Admixture Water) kg 162 162 **Free Water — Cementitious Material Ratio, by weight wie 0.39 0.39 Coarse Aggregate / Total Aggregate % 61 Cis Fine Aggregate / Total Aggregate % 39 39 ‘Cement + Silica Fume / Total Aggregate % 22 || “Total Mixing Water includes the Added Water and Ice in the Concrete Minture. **6 kg of water containing in the added liquid admixture which is based on 60 % of proportional ppnume of liquid admixture is considered as part of the mixing water and used in the calculation of tree Water Ratio. [W/C)]. “Appropriate adjustments made in the batch weights for the aggregate and the toll mixing water in the detereiecy Tu Which is based on the following aggregates moisture contents and absorption values ag determined. Material Description Average Absorption [Average Moisture Content {as determined {as determined) Fine Aggregate (Natural Sand) 13% [Combined Coarse Aggregate 0.75% Wad Avs pean SYED ARSHADULLAH BRANCH MANAGER-YANBU pig te dosararts Bund By Clicnt Khalid Awadh Athamdi Factory (K-MIX) _—————e Report No, SA15-9505/ Lab No. 6937 SSS Dated 03 Jane2018 Page ASTI TABLE #9A PLANT TRIAL MIX No. TM #9 FRESH CONCRETE PROPERTIES AND CONCRETE COMPRESSIVE STRENGTH TEST RESULTS PLANT TRIAL MIX PRODUCED AT K-MIX— BATCHING PLANT NO 2, YANBU DATE PERFORMED : 04 APRIL 2018 MIX DESIGN ID. NO. (REFERENCE ) : FSL / KM /30 MPa (OPC+S) CONCRETE GRADE ~ 30 MPa / K-MIX CODE : RC-09 RC CONCRETE CLASS DESIGNATION - Y30b (OPC1SF) CONCRETE TYPE : STRUCTURAL MICROSILICA CONCRETE. {a ‘CONCRETE MIX DETAILS Cement Type : OPC (Type D, Nominal Maximum Agaregate Size: 34° (19.0 mm), le Cement : 380 ko/in’, Microsilica: 35 kg/m’, W/C Ratio (Free) 030 ERESH CONCRETE PROPERTIES Description Sau | tempts Teper, content, | Une Initial Measurement 140 22.0 33.0 16 2445 After 30 Minutes 120 24.0 335 14 2435 COMPRESSIVE STRENGTH TESTING (ASTM C-39-16 Measured Average Specimens Diameter, mm Cross-Sectional Area, mm? Cyl.No. A B c D CyLNoA |B c D 152.5 1325 [1535 | 1530 18265 | 18265 | 18506 | 18385 E E c H E F G H 1535 1535 [1533] 1535 1sso6 [18506 | 18506 | 18506] — a age | Desiy”[ Maximum Goad] Cynder Compronive Srengih No. Tested ary | ) MPa (N/mm?) si A | orapnizois | 3 | 2450 601 32.9 4770 B ov Apri 20is_| 3 | 2455 607 33.2 | C | o7apaizors | 3 | 2455 619 334 4350 | D_| o7aprtzois | 3 | 2450 615 335 4860 Average} 333 4830 E MApril2018_ | __7_ | 250 800 432 6270 F MW April2018_| 7 | 2450 809 437 6340 ¢ MW Aprt2018 [7 (| 244s 826 446 6470 u MW Apri2018 | 7 | 2aas 318 442 6410 Average] 43.9 370 Z| ae BRANCH MANAGER-YANBU EV AYA Sige ‘TH SPW STH coool oad by a-Si Ra obo aedeagal SRST ATT TOA RY Armember ofthe Fugro group of companies with offces werauiae "8.406 Mia YAN Lab ten 2018 KMIX ix Des RCConce Mn Dongen eC SF459 de — Ci Rakin Aton a fee Seen Report No. SA15-9505 / Lab No. 6937 4 = Dated 03 June 2018 1 Page 3 GeentpireD) DAT N TABLE # 9B PLANT TRIAL MIX No. TM #9 PLANT TRIAL MIX PRODUCED AT K-MIX— BATCHING PLANT NO2, VANDUD DATE PERFORMED : 04 APRIL 2018 MIX DESIGN ID. NO. (REFERENCE) : FSL/KM/30 MPa (OPC#SR) CONCRETE GRADE - 30 MPa / K-MIX CODE : R09 RC CONCRETE CLASS DESIGNATION — Y30b (OPC+SF) CONCRETE TYPE: STRUCTURAL MICROSILICA CONCRETE - CONCRETE MIX DETAILS Cement Type : OPC (Type D), Nominal Maximum Agaregate Size :3/4” (19.0 mm), Cement : 380 kg/m’, Microsilica : 35 kg/m’, WIC Ratio (Free) : 0.39 ‘ERESH CONCRETE PROPERTIES : Concrete “Ambient Air RTE Deseription Sump. 1] Temperature, || Temperature, Content, | Unit Weight, mm. a ae g/m: Initial Measurement 140 22.0 16 2445 After 30 Minutes 120 24.0 2455 -OMPRESSIVE STRENGTH TESTING (ASTM C-39-16, Measured Average Specimens Diameter, mm Cross-Sectional Area, mm? Cyl. No. J K L Cyl. No. I K L 152.5 1525 1525 [1525 18265 1826518265 | 18265 Cylinder my reg i pea [ Maximum Load | Cylinder Compressive Strength No. Tested ays | Soy «Ny MPa (Nimm’) psi 1 O2May 2018 | 28 | 2455 898, 49.2 7140 J O2May2018 | 28 | 2455 903 493 7130 K @May201s [28 | 2450 907 49.7 7210 L ©2May2018 [| 28 | 2455 906 49.6 7200 i| | Average 495 | Wad AL gee — ~ Sencar a ss SYED ARSHADULLAH BRANCH MANAGER-YANBU, EVs AY AL Ogu Dated: 03 June 2018 =S== Page- 4 eee mo Seune (ACCREDITED) TABLE-9C SUMMARY OF TEST RESULTS CHLORIDE PERMEABILITY OF HARDENED CONCRETE PLANT TRIAL MIX PRODUCED AT K-MIX— BATCHING PLANT NO 2, YANBUD DATE PERFORMED : 04 APRIL 2018 MIX DESIGN ID. NO. (REFERENCE ) : FSL/ KM /30 MPa (OPC+SF) CONCRETE GRADE - 30 MPa/ K-MIX CODE : RC- ‘ATION — Y30b (OPC+S) CONCRETE TYPE ; STRUCTURAL MICROS! CONCRETE MIX DETAILS Cement Type : OPC (Type D), Nominal Maximum Aggregate Size : 3/4” (19.0 mm), Cement | 380 kg/m’, Microsilica 35 kg/m, WiC Ratio (Free) : 0.39 Chloride Permeability, Total Charge Passed (Coulombs) AASHTO T-277-15 / ASTM C 1202-17 ‘Test Specimen # 1 28 days 967 + =| Test Specimen # 2 28 days 944 Sample Nos. Age at Testing Test Specimen #3 28 days 931 Average at 28 days > 947 Chloride Ion Permeability Based on Charge Passed as Very Low Range per “Table 1” of ASTM C1202-17 / AASHTO 1277-15 (100 - 1000) *Project Specificaiton Chloride fon Penetrability Based on Charge Passed. “RC Project Specification “CAST-IN-PLACE CONCRETE, SECTION 033007 1 Very Low 1000 (Max.) Note: The test specimens were obtained by drilling from standard laboratory cured concrete cubes at the age of 28 days. Remarks: The test result indicated that the chloride permeability at 28 days is within the project Specified limit and the chloride permeability is catagorized in “Very Low” range, WAL AL eae con 3 — Suna Ss EVs PAYAL Ogu BRANCH MANAGER-YANBU [Amomber ofthe Fugro group of companies with offces werowia "Ts Sepa Soi way Fei La Way a0 TIT STP RST GSTS Te eampany 17218400 ab VAN Lab Cen KMIEM Deen he Com ts Den ee ACI SE-59 den Client Khalid Awadh Alhamdi Factory (K.-MIX) Report No. SA15-9505 / Lab No. 6937 Dated: 03 June 2018 Page- 5 TABLE - 9C-1 CHLORIDE PERMEABILITY OF HARDENED CONCRETE - DATA AND CURVE (CURRENT VERSUS TIME) (Current in mA Elapsed Time in Sec, x 100 04 Apel 2018 1.277 ~15/ ASTM C 1202-17 Date Tost 02 May 2018 “Rapid Determination of the Chloride Permeability of Concrete”. 28 days “Core Test Specimen No. 1 05 mm@x60 miony sie) Location of Specimen Sizesavm fom the lop tutace of tho Cube Coulombs | surtace Treatment 2 None 32] Mic taontitcation Kote x Code :Re-00 76 Plant Ta Mix Ho, TM #9 77 Concrete Grade 301MPa -RC Desgnaon Y 308 (OPCxSF) 70 —| coment 380 kgim?(OFC, Type) 81 | Microsiica(Siica Fume): 35g? 83] wre Ratio (Free) + 030 83___] Total Cementitous Material + 46 kai 83 144 46. 83 ‘corde Permeabi F 162 45 83_| (Total charge Passed) + 967 Coulombs 80) ga Go| Remarks: From Table tof AASHTO T-777 and based on argo 198, 48 83 Passed for the specimen tested, the chloride permeabilly is 26 46 41__| considered to be Very Low, Note] (G2%9 est specimen sblained by arling from a standard laboratory — cured Sonerale Gabe {150 x 150 mm), The cube specimen cast by FSL on O4 Apr 218 Ad AL gates Spain Ae. A- a Srabanstanuna PAYAL Cage BRANCH MANAGER-YANBU ‘The Sopviaht fis document oumed Amembor ofthe Fugro group of companios with ofces wore 7218.10.10 MaternLab-YAN Lab.2Cena201 SKIKE Desa Ne-Conscr Mn Daa ea Client Khalil Awadh Alhamdi Factory (KMIX) Report No. SA15-9508 / Lab No. 6937 Dated: 03 June 2018 Page 6 DA TH TABLE -9C-2 CHLORIDE PERMEABILITY OF HARDENED CONCRETE - DATA AND CURVE (CURRENT VERSUS TIME) i j 8 Elapsed Timo in Se. x 100 04 April 2018 AASHTO T 277 — 15 / ASTM C 1202-47 Date Tested (02 May 2018 “Rapid Determination of the Chloride ‘Age at Testing | 26 days Permeability of Concrete Elapsed “Core TestspecinenNo.: 2(05mm@xe0rmiongsic) +d Time in Location of Specimen: Slice saun from the op surface ofthe Cube Sec.x 10? Coulombs | surface Treatment 5 None 0 29 | mix identification Ketix Mix Code : R¢-09 18 68 Plant Trial Mix No, TM #9 36 72__| Concrete Grade 30 MPa - RC Designason ¥ 206 (OPGSF) 54 76 | Cement + 980 kon? (OPC, Type |) 72 79 | MicrosiicaSiica Fume): 35 kg/m? 90 81] WiC Ratio (Free) 039 108 83] Total Comentitious Material : 450 kgm! 126 83 144 83, Chloride Permeabii [oz Se scnenos 180 Ee | Remarks: From Tablo 1 of AASHTO T - 277 and based on charge 108 83 passed for the specimen tested, the chloride permeabilily “1s zion 41 | considered to be Very Low. [Note “Core test specimen obtained by drilling froma standard laboratory — cured conerete cube (150 x 150 mm). The cube specimen cast by FSL on 04 April 2018, Nk SYED ARSHADULLAH BRANCH MANAGER-YANBU frien approval fom Company riswide RC-ConecteMin Dest.) MPOBCSSE.6937 dos ‘ Client Khalid Awadh Alhamdi Factory (K.-MIX) Report No. SA15-9505 / Lab No. 6937 Dated: 03 June 2018 Page. 7 SA AT EN TABLE -9C-3 CHLORIDE PERMEABILITY OF HARDENED CONCRETE - DATA AND CURVE (CURRENT VERSUS TIME) < E é é OC) aest0l, 57h, (ety Tle’ G00 Mee fostticsi ted el teo sa ieo tosis igaaat Elapoed Time in Sec. x 100 Date Sampled 04 April 2018 AASHTO T 277 ~ 15 / ASTM C 1202-17 Date Tested (02 May 2078 “Rapid Determination of the Chloride Ageat Testing | 26¢aye | Permeability of Concrete’. Pispeed “Gore Test Specimen No. + 3 (05mm 0x50 nm long sce) =] Time in Milli- Location of Specimen ‘Slice savm from the top surface of the Cube Secx10* | Amps. | Coulombs | scrtace treatment None 0 30 27___| Mix dentiication Ketlix Mix Code: RC-09 18. 36 65 Plant Trial Mix No. TH #9 lemaa 38 68__| Concrete Grade 30 MPa - RC Designaton ¥ 306 (OPC+SF) 54 40 72__| coment 380 kgim*(OPC, Type |) jeer 42 76__| MicrosiicaSiica Fume): 35 kai? 20 43 77____| WIC Ratio Free) 030 408 45 81 | Total Cementitious Material ; 450 kgin? 126 46 83 144 47 85 Chloride Permeabil [192 ar as | tie ements mae 180 Ar 85 remarks: From Tablo 1 of AASHTO T - 277 and based on charge 198. 47 85, Passed for the specimen tested, the chloride permeabilly is 216 47 42 | considered to be Very Low. Li2ie | a ae Note ‘Fare test specimen obiained by driling from a standard laboratory ~ cured concrete cube (150 x 150 mm). The cube specimen cast by FSL on 04 April 2018. aa SYED ARSHADULLAT BRANCH MANAGER-YANBU Ye NATAL S.Gu Amember ofthe Fugro group of companies with offces wero ‘THE CDI Ws doses owned Fea Sun L Na tba oedand cal ih pa waar aval FON CSMPRY Oo {7218.40 10atrsLob-YAN Lab-2Cen2018 KM Mn Dein RC Gontce Mik Daign THESIS ne SECS 97d : Dated 03K 01 OS ae Ceti 51208 TABLE -9D CHLORIDE AND SULFATE CONTENT IN HARDENED CONCRETE PLANT TRIAL MIX PRODUCED AT K-MIX — BATCHING PLANT NO 3, YANDUD DATE PERFORMED : 04 APRIL 2018 MIX DESIGN ID. NO. (REFERENCE ) : FSL/ KM / 30 MPa (OPC+SR) \ CONCRETE GRADE ~ 30 MPa / K-MIX CODE : RC-09 RC CONCRETE CLASS DESIGNATION — Y30b (OPC+SF) CONCRETE TYPE : STRUCTURAL MICROSILICA CONCRETE CONCRETE MIX DETAILS Cement Type : OPC (Type | Maximum Aggregate Size : 3/4” (I Cement ; 380 kg/m!, Microsilica | 35 kg/nr', WIC Ratio (Free) DETERMINATION TEST RESULTS TESTSAMPLENOS.| #1 | #2 | #3 | Average] — Project Specification Chloride Content (BS 1881, Part 124) 1. Chloride Content (as Cl), % by wt. of concrete (Acid Soluble) *Chloride Content (as Cl), % by wt. of Cement 0.108 | 0.13 (Max,) (Acid Soluble), Average 0.018 | 0.018 | 0.021 | 0.019 . Sulfate Content (BS 1881, Part 124) 2. Total Sulfate Content (as S04), 3 % by wt. of conerete, (Acid Soluble) O61 | 0.62 | 062 | 052 *Total Sulfate Content (as SOs) % by wt. of Cement 351 | 40 (Max) (Acid Soluble), Average “Calculated values based on the average dry density of 2350 kkg/m* and total cementitous material content of | 415 kp/m* Note: The pulverized test samples were obtained from the standard laboratory cured concrete cube specimens at the age of 28 days. Remarks: The test results indicated conformance to the project specification requirements for the sulfate and chloride contents in the hardened content. SYED ARSHADULLAH BRANCH MANAGER-YANBU ‘Amember of te Fugro group of companies with offices worlwide "The copyiht ofits dociment ced by Fore Sahai Ld Wrmay nok be SARS cept wth prior witten approval rom compary On jen-TMS 30 MPOPC'SF-6937 de 7 pn -Svnamn Client Khalid Awadh Alhamdi Factory (K.-MIX) a] _————= Report No. SA15.9505 / Lab No. 6037 == Dated: 03 June 2018 = —~ Page- 9 SAA STII TABLE ~95 SIEVE ANALYSES OF AGGREGATES AND COMBINED GRADATION PLANT TRIAL MIX PRODUCED AT K-MIX — BATCHING PLANT NO 2, YANBUT DATE PERFORMED : 04 APRIL 2018 MIX DESIGN ID. NO. (REFERENCE ) : FSL / KM /'30 MPa (OPC+SE) CONCRETE GRADE ~ 30 MPa / K-MIX CODE ; RC-09 RC CONCRETE CLASS DESIGNATION ~ Y30b (OPC+SF) CONCRETE TYPE : STRUCTURAL. MICROSILICA CONCRETE. CONCRETE MIX DETAILS. Cement Type : OPC (Type D, Nominal Maximum Aggregate Size : 3/4” (19.0 mm), [a eee 380, kg/m’, Microsilica : 35 kg/m’ WIC Ratio (Free) : 0.39 a Sieve Analysis (ASTM C-136 & C-117) Percent Passing by Weight Nominal Size eae ae Par a Natural | *Combined Gradation 1" (25.0 mm) 100 100 100 100 100 3/4" (19.0 mm) 93 100 100 100 98 5/8" (16.0 mm) 63 100 100 100 89 1/2" (12.5 mm) 18 90 100 100 3 3/8" (9.5 mm) 2 25 95 100 58 No. 4 (4.75 mm) 0.5 07 18 96 40 No. 8 (2.36 mm) 0.5 05 10 89 35 No. 16 (1.18 mm) 0.5 0.5 0.7 75 30 No. 30 (0.600 mm) 05 05 0.7 50 20 No. 50 (0:30 mm) os | os | o7 21 9 No. 100 (0.150 mm) 05 05 07 9 4 No. 200 (0.075 mm) 0.4 Os 0.6 38 18 * Combined gradation of the coarse and fine aggregates based on a blend of aggregales in the following eee Y Weight as proposed in the conerete mix design formulated by FSL for 30 MPa structarat mierosilica concrete. Aggregates Proportions Material Type “eercntags Teal bad 3/4" (19 mm) Coarse Aggregate 3 1/2" (12.5 mm) Aggregate 15 3/8" (9.5 mm) Coarse Aggregate 15 Fine Aggregate (Natural Sand) 39 WadhAd gtses ac -Senana ED ARSHADULLAH BRANCH MANAGER-YANBU V0 AVAL See "TISSSPIHON Federer owed by Fie Gai LA Way be epecnd Oca wh ar wan opal FOO GAGS Amember of te Fugro group of companies with ofces wean {7218140 10MarisLb-Y AN Lah Clt-2018KMIX Mic Design RC Conse k Dene EO ha oS. dew ree — Suna Client Khalid Awadh Alhamdi Factory (K-MIX) -] aes _——— Dated: 03 June 2018 Page- 0 IPR ST) TABLE -9F MIX DESIGN PROPORTIONS COMBINED AGGREGATE GRADATION CONCRETE GRADE ~ 30 MPa CONCRETE TYPE : STRUCTURAL MICROSILICA CONCRETE. US, SIEVE OPENING WINCHES US. SIEVE NUMBERS HYOROMETER 3215 34 xe 4 6 81 1620.90 4 5 10 200 Combined Aggregate Gradation of Recommended Mix Proportions © Project Specification Gradation "B" Limits ie ST = ‘00 0 + Grain Size, mm 04 oot cos ans “Percent Passing ‘"*Project Specification by We Gradation "B" Limits 1" 25.0 mm 100 100 3/4" (19.0 mm) 98 = 5/8 (16.0 mm) 89 35-90 1/2" (12.5 mm) 3 : 3 | 3 3/8" (9.5 mm) 38. 40-65 |= 3 No.4 (4.75 mm) 40 30-50 | : No. 8 236mm) 35 25-48 = No. 16 (1.18 mm) 30 15-35 |. e ‘No. 30 (0.600 mm) 20 10-25 [RE : No. 50 (0.300 mm) 9 Ca is : No. 100 (0.150 mm) 4 0-8 2 oi LNo.200 (0.075 mm) 18. 0-2 Note] “Based on the coarse and fine ageegaies gradation and Blend proportions by weight as proposed in ie conse mix design formulated by FSL. “*Recommended Combined Aggregate Gradation “B" Limits as given in Table 2.1 D of the Project Specification, Remarks] The test eslt indicated conformance to the project specification requirement for the compet ‘aggregate gradation of the recommended mix. "TRS envi of acer ed Fog Shah La Wyte aoad ap Pl wn Spa FO arpany Amember ofthe Fugro group of companies with ofices werowice 17218140 L0Materai.sb-YAN Lab-2Cets201BKMIX Mi Dein RC Conte Mik Deon THES SG CSET doe = Client Report No, Dated : SA15-9505 / Lab No. 6937 03 June 2018; Khalid Awadh Athamdi Factory (K.-MIX) aeeteakY Geant 1208 TABLE - 9G RECOMMENDED MIX PROPORTIONS [[Coarse Aggregate Quarry at KM 19 from Yanbu-Jeddah Highway Fine Aggregate (Natural Sand) Quarry near Yanbu Al-Nakhl Road Mixing Water/ Ice Water Potable Water Supply, Yanbu Cement (Type I OPC) ‘Yanbu Cement Co. Liquid Admixture (MasterRheobuild 563) ‘Master Builders Co. (BASF) Mineral Admixture (Densified Microsilica) FerroPem, France CONCRETE TYPE STRUCTURAL MICROSILICA CONCRETE MIX DESIGN ID NO. (REFERENCE) FSL/ KM/30 MPa (OPC+SF) CONCRETE GRADE / AL-MASSAD MIX CODE | 30 MPa/RC-09 CEMENT TYPE Type 1(OPC) RC CONCRETE CLASS DESIGNATIO? Y¥30b (OPC#SF) Constituents 1 m’ SSD Proportions (Based on Actual Yield). ‘Cement (Type - I, OPC) kg 380 Densiffied Microsilica (Siliea Fume) kg 38 Total Cementitious Material kg 415 Free Water, (Water + Ice) kg 156 3/4" (19 mm) Aggregate kg 370 1/2" (12.5 mm) Aggregate kg 285 3/8" (9.5 mm) Aggregate kg 285 Fine Aggregate (Natural Sand) kg 730 Liquid Admixture (MasterRheobuild 563) liter 8.0 “Free Water (Water + Ice + Admixture Water) kg 162 *Free Water-Cementitious Material Ratio, by weight whe 0.39 Coarse Aggregate /Total Aggregate % 61 Fine Agercgate / Total Aggregate % 30 Cement + Silica Fume/ Total Aggregate % 2 Notes: 1. *The water in the admixture becomes a part of the mixing water in the concrete and is considered In the calculation of WIC Ratio. 2, The mix proportions are for agaregates ina saturated surface dry condition (SSD). The actual batch Weights for aggregates and total mixing water weight should be adjusted accordingly by performing ‘moisture contents and absorptions on aggregates regularly. 3, The correct measurement of total mixing water depends on the quantity and variation of the ‘moisture in the ageregates as itis batched. SYED ARSHADULLATT BRANCH MANAGER-YANBU Vee P AVAL Seow ~The Owed Fog Ss Li Wy rb ado RW GWG TTT cama Amember ofthe Fugro group of companies with offices werowaa 17218 14010 MatrsLab-Y AN Lab-2Ceas-2018 MIX Mi Dep RC Connie Mik Daige Eae a Cs SF-6937 doe

You might also like