FIRE ALARM
FIRE ALARM Uncompromising fire protection
at the highest level
Safety is no coincidence – it is the result of many years of
experience combined with innovative technology.
Clear information about the situation and about The possibility of line interruptions – which
each event, as well as unrestricted operability of could be caused by construction work on the
the entire fire detection and extinguishing system premises, expansions and modernisation or even
are essential requirements for every situation. For a fire itself – cannot be ruled out. For this reason,
this reason, connections and interfaces to external all internal system connections and also the entire
operating and indicator panels are duplicated. network of Integral IP systems are implemented
This form of redundant operating panel interface according to a redundancy system. In case of
ensures full operability of the system and a clear connection problems, the mesh network
display of all events, with clear information automatically and without interruption finds
regarding location and time, even in the event of an alternative route. The system remains
failure of a line. Control panels in the fire alarm fully active and there is ample time to
control panel can thus be economised and operation properly plan repairs and rectify any
takes place where it is needed. possible malfunction.
hot standby energy x 2
wire break
Bus x 2
processor x 2 data x 2
software x 2 short circuit
All modules, power supplies, bus systems and software All automatic fire detectors, manual call points, acoustic
routines of the Schrack Seconet Integral IP MX fire and visual alarm devices and control modules are
alarm control panel are redundant. If the active side connected in a loop system. Thanks to the short circuit
fails, the second system – which constantly runs in isolator, which is without exception integrated into every
“hot standby” mode – takes over automatically and loop circuit device, the loop can be wired and configured
without interruption. Any fault is therefore across all fire sections and functions. If there is a short
compensated, no matter where it occurs. The fire alarm circuit, the integrated short circuit isolator disconnects
system always remains fully operational and fires can the damaged part of the line, and all the devices on the
be detected quickly and reliably, even in the event of X-LINE are connected via the remaining stub lines and
a fault. All data and messages are reliably conveyed remain fully functional – just as in the case of a wire
and processed, and all fire control systems – e.g. breakage. Accurate localisation of the damaged line
ventilation flaps, fire compartment doors and section facilitates troubleshooting and saves valuable
extinguishing functions – are controlled. commissioning and service time.
FIRE ALARM Intelligent remote access for more
convenience and efficiency
Be informed at any time and respond quickly.
Remote access via Integral Remote offers a Integral Remote Notification
multitude of solutions: convenient monitoring Notifications
directly at the workplace, mobile notifications
in real time on a smartphone or tablet,
uncomplicated live support and much more.
Information is delivered to where it is needed Integral Message *
and provides a decisive time advantage
to act – absolute safe and comfortable.
Efficient operation
Live support
Integral Remote Professional
Experts and technicians have access to the system Programming
as required, and can quickly and easily provide by installer
remote assistance to local users.
Remote programming
CERTIFICATE
PC-VPN
S2service Connect
• Connection management
• Logging of events
• Managing users and
permissions
Integral Mobile
CERTIFICATE
Router-
VPN
Integral Desktop *
Dongle
CERTIFICATE
PC-VPN
Larger buildings and complexes such Very large-scale systems or even facilities distant
as hotels, office buildings, industrial from one another require fire detection systems
plants etc. are efficiently fitted with with special network capabilities. With the
an Integral LAN. Up to 16 control premium network, Integral WAN, previously
panels can be connected as desired impossible system configurations that meet the
in a stub, loop or mesh topology to highest demands are now available. Systems grow
form a logical fire alarm control panel along with buildings, and even older generations
and can also be easily expanded later. of control panels can be easily integrated.
tibility and
SecoLOG IP
Modernisation
Extensive premises with campus Integral WAN connects fire alarm With the premium network
structures, such as hospitals or systems regardless of their distance. Integral WAN, control panels of different
universities, and large-scale facilities, Complex networks – from companies generations can be interconnected.
such as shopping centres or large public with branch structures such as Expansions carried out using the latest
buildings, can be optimally networked supermarket chains or companies with technology are integrated effortlessly with
with an Integral WAN and can be multiple branches, to unoccupied and existing facility components. Extensions
efficiently managed via a central alarm scattered facilities such as wind farms – and changes in the use of buildings can
management system. can be operated remotely. be implemented flexibly at any time.
FIRE ALARM Customised components
for all applications
MXF CXF BX
MXE CXE
Integral IP fire alarm
control panels
Integral IP MXF Integral IP CXF Integral IP BX The Integral IP system family consists of
Structure modular, decentralised compact, decentralised basic different control panels, housing variants
and components which can be perfectly
Optimised for the large systems and medium-sized systems, smaller buildings,
protection of buildings, for example, for example, for example, combined and matched to systems of any
• Industrial facilities, • Residential • Unoccupied configuration and size. All devices are based
• Office buildings, developments, technical equipment, on the same high-quality technology, are
• Airports, • Large supermarkets, • Catering facilities, compatible with each other and use the
• Hospitals, • Hotels, ... • Underground same commissioning and software tools.
• Shopping centres, ... car parks, ... The detectors and modules of the X-LINE
Redundancy can be connected to all control panel types.
Loops per control panel up to 16 up to 4 1 The user interface is also identical
for all Integral IP panels.
Elements per control panel up to 4,000 up to 1,000 up to 250
TCP/IP interface
Networkable via TCP/IP
Modernisation of
existing systems
Floor standing cabinet
Integral IP extinguishing
control panels
Integral IP MXE Integral IP CXE The control panel types Integral IP MXE
Suitable and approved for • CO2 high pressure and low pressure extinguishing and Integral IP CXE can be used as
monitoring of systems with and without a danger to the safety extinguishing control panels according to
of people the standard (electrical control and delay
• Inert gas and argon extinguishing systems with device according to EN 12094-1 and
and without a danger to the safety of people VdS 2496) or as a combined fire alarm /
• Spraying water & misting water extinguishing systems extinguishing control panel.
• Pre-action sprinkler systems
• Sprinkler systems
• Chemical extinguishing systems
Controlling single-zone extinguishing systems
Controlling multi-zone extinguishing systems
Number of extinguishing zones up to 32 1
Additional parallel LED displays
Additional freely programmable
inputs and outputs
External operating
and indicator panels
CMD 533X
MTD 533X
Settings according to EN 54
For manual triggering of a fire alarm For acoustic and/or optical signalling
according to EN 54-11, a variety of manual of a fire, Schrack Seconet offers a variety of
call points (type A or B) are available in signalling devices in various colours and
different versions and with different protection designs. All devices have an EN 54
classes. The portfolio also includes manual certification and/or a VdS-approval.
call points in other colours as well as stop In addition, there is a complete range of
and actuation buttons for manual triggering flashing lights that conform to the
an extinguishing operation. EN 54-23 European standard.
There are a large number of control modules The door holding magnet is used for automatic
for the connection of peripheral devices. closing of fire doors in the event of an alarm.
Depending on the model, potential-free Unlike with conventional magnets, this is not
contacts can be interrogated, hazardous areas permanently powered, but keeps the door
monitored, loads switched by relays, or special open with a permanent magnet entirely
fire alarm systems can be integrated. without energy consumption.
X-LINE
The Integral X-LINE offers the perfect combination of detection and alerting. At a length of up to 3,500 meters,
up to 250 high-performance and energy-efficient loop circuit devices can communicate with the fire alarm control
panel. The short circuit isolator, which is integrated into every X-LINE device as standard, ensures planning
security as well as unlimited functioning in the event of a short circuit, wire break or sabotage.
FIRE ALARM Reliable detection under the
most difficult conditions
With the special fire alarm technology
product range, Schrack Seconet offers
the right solution for every application,
thereby guaranteeing fire detection even
under the most difficult atmospheric
conditions, such as extreme air
humidity and pollution, high
temperatures and high
altitudes etc.
Thanks to the unique “Config over Line” These are robust, durable and highly sensitive
function, configuration, commissioning and to developing fires, suitable for fire protection
maintenance of special fire detectors that in high rooms and halls as well as for areas
are connected directly to the loop can be that are hard to reach. They also offer an
carried out quickly and conveniently from ideal solution for technical infrastructure
the control panel. Data exchange and monitoring, e.g. electrical cabinets,
communication take place via the machinery for manufacturing technology
existing X-LINE. or computer systems.
Linear smoke detectors Flame detectors
These are used where the maximum These are used to detect smokeless
installation height of conventional liquid and gas fires as well as smoke-
fire detectors is exceeded, the visual intensive, open fires in hazardous areas.
appearance may not be affected or Typical applications are large industrial
large areas must be monitored, warehouses, aircraft hangars, chemical
such as in high industrial, public plants, oil refineries, engine rooms,
or historic buildings. power stations etc.
In extreme conditions such as heat, humidity, The addressable LIST sensor cable is For fire detection in
dust and steam or gas development, these prove characterised by precise detection and ventilation systems or in places
to be particularly reliable. The robust temperature high response speed, as well as easy with high air velocity and
sensing tube is ideal for high-temperature installation and commissioning. strong smoke dilution.
applications such as foundries, or areas with Various sensor distances, branches Early smoke detection prevents
extreme temperature fluctuations such as industrial in the sensor cable and individual fire and smoke from spreading
kitchens. Potentially explosive environments are temperature sensors provide the within and through the
best protected by a special evaluation unit. perfect solution for every application. ventilation system.
COMPETENCE
ON TOP
SCHRACK SECONET AG
Headquarter Austria: A-1120 Vienna, Eibesbrunnergasse 18 • Tel. +43 1 81157 • office@schrack-seconet.com • www.schrack-seconet.com
Branch offices in Austria: Czech Rep. • CZ-149 00 Prague 4 - Újezd., Štítová 283 • Tel. +420 2 74784422
A-6850 Dornbirn, Sebastianstraße 13a • Tel. +43 5572 51199 Hungary • HU-1119 Budapest, Fehérvári út 89 -95 • Tel. +36 1 4644300
A-8055 Graz, Neuseiersberger Straße 157 • Tel. +43 316 407676 India • IN-122102 Gurgaon, C-704A, Pioneer Urban Square, Sec-62 • Tel. +91 124 4141501
A-6020 Innsbruck, Dr.-Franz-Werner-Straße 36 • Tel. +43 512 365366 Poland • PL-02-972 Warsaw, ul. Branickiego 15, Wilanów Office Park, bud. B1 • Tel. +48 22 3300620
A-9020 Klagenfurt, Eiskellerstraße 3 • Tel. +43 463 429362 Romania • RO-023961 Bucharest, Str. Mântuleasa nr. 15A et. 1, Sector 2 • Tel. +40 372 756316
A-4060 Leonding-Hart, Kornstraße 16 • Tel. +43 732 677900 Russia • RU-129626 Moscow, Ul. Staroalexejevskaja 5 • Tel. +7 495 5105015
A-5020 Salzburg, Vogelweiderstraße 44a • Tel. +43 662 887122 Slovakia • SK-83527 Bratislava–Rača, Mudrochova 2 • Tel. +421 2 44635595
© Schrack Productions - B-PR-615EN - V 2.0 - 05.2019
Sweden • SE-126 30 Hägersten, Västberga Allé 60, Plan D • Tel. +46 8 6801860
Turkey • TR-34718 Kadıköy-Istanbul, Koşuyolu Mah. Ismailpaşa Sok. 78 • Tel. +90 216 3455199
Sales partners in: ARM AZ BG BIH BY CH CY D DK E EST ET F FIN GE GR HR I IL KS KSA KWT KZ L LT LV MK N NL P PK RB RL SLO SRB TM UA UAE UZ
FIRE ALARM