Table of Content
1. Introduction .................................................................................................... 3
2. Features .......................................................................................................... 3
3. System Specification ....................................................................................... 4
3.1 System Details ........................................................................................................4
3.2 Shipping includes ....................................................................................................4
3.3 Connection Details of Indicator ...............................................................................5
3.4 Function of Keys ......................................................................................................6
3.5 AT Keyboard Details ................................................................................................6
3.6 Hint for Data entry ..................................................................................................6
4. System Overview ............................................................................................. 7
4.1. General Working Process .......................................................................................7
4.2. Dump Record to PC.................................................................................................7
5. Configuration of System .................................................................................. 8
5.1 Menu Flow Chart .....................................................................................................8
6. Load Calibration .............................................................................................. 9
6.1. Load Calibration Tips ..............................................................................................9
6.2. Procedure for Calibration .......................................................................................9
7. RTC ................................................................................................................ 12
8. Setup ............................................................................................................. 13
9. Diagnostic...................................................................................................... 20
10. Record Details ............................................................................................. 23
11. Vehicle Data Entry ....................................................................................... 24
11.1. F1 Key: Vehicle Entry .........................................................................................24
11.2. F2 Key: Recall .....................................................................................................26
11.3. F3 Key: Initialize ................................................................................................26
11.4. F4 Key: Vehicle Re entry .....................................................................................26
11.5. F5 Key: Master Code Data Entry .........................................................................27
11.6. F6 Key: Code & Date Wise Summary Report .......................................................27
11.7. F7 Key: Code Wise Summary Report...................................................................28
11.8. F8 Key: Data Wise & All Summary Report ...........................................................28
11.9. F9 Key: Truck Wise & Truck with Data Wise Summary Report ............................29
11.10. F10 Key: Tare the Weight .................................................................................29
12. Configuration of Printing Bill ....................................................................... 30
12.1. Weightment & Summary Bill Entry Symbol .........................................................30
12.2. Configuration of Summary Report ......................................................................31
12.3. Configuration of Weighment Report ...................................................................33
12.4. Configuration of Pre - Print Weighment Report ..................................................34
12.5. Single Touch Report ...........................................................................................35
12.6. SMS Facility ........................................................................................................35
13. Troubleshooting........................................................................................... 36
14. Annexure – I................................................................................................ 37
14.1. Do’s ....................................................................................................................37
14.2. Don’ts .................................................................................................................37
Version 1.0.6 -2 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
1. Introduction
AWEW -2000 is a stand-alone system, which is used to process and store all the weigh bridge
activities. System operates with the help of some peripheral devices like AT Keyboard for data entries,
serial printer for bill printing and LED & LCD display for display status. Sys tem stores the weighing
data up to max. Of 65000 records with warning indication from 64995 th record.
2. Features
6 digit 0.56” LED display available to display the current weight.
Continuous data (Weight) dump via RS232 (Com Port -2) for REMOTE display.
All records can be dumped to PC (HyperTerminal software tool) via RS232 (Com Port -1).
Print bill format (Summary Report, Weighment Bill) can be created, edited then stored.
Print Bill title & Footer, Vehicle Entry, Re -Entry can be configurable.
Version 1.0.6 -3 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Model AWEW-2000
Operating Voltage 24 VDC (12-32 VDC)
Power consumption 10 watts
6 Digit 0.56” inch Red Color 7 Segment LED Display & 2 x 16 LCD
Display
Display
Transducer Excitation +5V DC.
Keyboard AT – Key Board (Logitech / TVS)
2 - Serial Com Ports (8 bit - Data bit, 1bit -Stop bit, Parity – None)
Communication
Baud Rate refer Setup – Menu.
Printer Dot Matrix Serial Printer
Transducer Connector type Terminal Block(5.08 mm)
Internal Count -131071 to +131071
Gain 128 (Fixed)
Resolution 1 in 10,000 (External)
Error ± 0.05%
Dimensions(L x B x H) 62 x 194 x 98 mm
Version 1.0.6 -4 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
7-segment
Display
Keyboard
Connector
LCD
Display
Version 1.0.6 -5 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Version 1.0.6 -6 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
4. System Overview
AWEW is a stand-alone system, which is used to process and store all the Weighbridge
activities.
1. Switch „ON‟ the System, the display shows the Company Name, “Version Number”.
‟ Initialising…‟ and Indicator will load the system setting.
2. LED shows Current Weight & LCD shows Current Date & Time (this is Normal mode).Press UP
key to see the signal level of the GPRS Module(NC -> No connection,1-31 -> signal level).
3. Connect Load cell cable at the rear panel. This is four wire system.
Version 1.0.6 -7 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
5. Configuration of System
Press F12 Function key in keyboard (or) Menu Key on keypad to select Menu Access, System
shows “Enter Password”. After giving correct password select the Sub - Menu using UP or DOWN key
on keyboard (or) UP Key in keypad to select various options.
Press ENTER key to enter into that Menu & ESC key is used to exit from Menu.
Menu
Select Option
Version 1.0.6 -8 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
6. Load Calibration
Note:
“Calibration Disabled” message will be displayed if the calibration lock given.
i. Capacity
ii. Resolution
CALib Select the Resolution of the Weight is to display and print in bill.
Resolution are 1, 2, 5, 10, 50, 100
Resolution
Default is 10.
Version 1.0.6 -9 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
iv. Unit
CALib Select the Unit of the Weight, Units is Kg, N, lb, Ton.
Default unit is Kg.
Unit
Kg
v. Calib - Zero
To Store the empty Pan count (raw ADC) in system, now keep the
CALib Pan Empty.
Press ENTER key to store the ADC counts and system will display message
Calib - Zero as “ Accepted ”, if ESC key is pressed system will display message as
“ Not Accepted ”.
To Store the Span Load count in system, now keep the Known
CALib weight on the Pan (Platform).
Press ENTER key to store the ADC counts and system will display
Calib - Span message as “Accepted”, if ESC key is pressed system will display
message as “Not Accepted”.
CALib Enter Span Weight by using ARROW keys and press ENTER key to
store the Weight.
Version 1.0.6 - 10 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Version 1.0.6 - 11 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
7. RTC
Real Time Clock is provided in the Weigh bridge print and store time, Date & Day in the bill
and in record. Date & Time are programmable. The time runs in 12/24 hours mode depending upon
the selection.
As like other data entry, select the RTC menu and press ENTER key. Time is entered as
HH:MM:SS & Date is entered as DD/ MM/ YY.
* RTC *
Press ENTER key to Select the RTC Menu.
RTC - Date To Set the date in the format DD/MM/YYYY press ENTER Key
By using Up Key and Right Key or Left Key enter the Date then Press
SET DATE ENTER Key to Store the Date.
05/03/2018 Default Date is 01/03/2018.
RTC - Time
To Set the time in the format HH:MM:SS press ENTER key .
RTC - Time By using UP key and RIGHT or LEFT key change the RTC Time after
01:50:07 entering the Time press ENTER Key to Store the Time.
Default Time is 01:00:00 .
7.3. Initialise RTC
Here to Initialise the RTC to Default Date & Time.
INITIALIZE RTC
Default Date is 01/03/2018, & Time as 01:00:00
Version 1.0.6 - 12 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
8. Setup
To Configure the Vehicle Entry, Re – Entry, Bill & Summary Printing, Change of password.
System Shows
1. Device ID
Version 1.0.6 - 13 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
4. COM-2 Mode
To select the COM-1 Mode Printer, PC or Single Touch.
CO M - 2 M ode If Printer is selected, User can perform the weighment from
indicator.
If PC is selected, weighment from indicator is restricted. PC
protocol will dump through COM-1 continuously.
If Single Touch is selected, report will be printed with serial
number, date, time, current weight. User can enable/disable serial
number, date and time.
If single touch menu enabled, then entry/Re-entry related menus will
not displayed. At this time “Print Para. Sel” menu will be displayed.
In this menu user can enable/disable the serial number, date and
time for Report.
If Printer/PC selected, entry/Re-entry menus will be displayed.”Print
Para. Sel” menu will not be displayed.
Default COM-1 Mode is Printer.
5. COM-2 Mode
To select the mode of C om - 2.
SEtUp
Available modes are Remote Display-1, Remote Display-2, GPRS
Com - 2 M ode Module, and Disable.
Default is Remote Display-1 .
6. Power On Tare
At the time of power on the system, if Tare Weight is less or equal to
Power on Tare (%) of Maximum Capacity, then that weight will be
tared.
PowerOnTare(%)
Default Power on Tare% is 004.
7. ManualTare%(F10)
if Tare Weight is less or equal to 4% of Maximum Capacity, then that
SEtUp weight will be tared.
Default Manual Tare% is 04.
M anualT a re %( F 1 0)
8. Auto Zero
SEtUp To select the auto zero range from 0 to 9 Resolution. 0 to disable the
Auto Zero Operation. For eg. 3 is selected if Resolution is 5 Kg. The
Au to Z er o auto zero will done between 3 x 5 = ±15 Kg.
Default: Auto Zero is Disabled.
Version 1.0.6 - 14 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
SEtUp E nt er t he d i g it a l f il t er l e ve l wi th i n th e ra n ge m inim um 1 t o
m ax im um 9.
AD C F ilt e r
M ov ing Av g
SEtUp To set the User Password. This password is valid only to Edit Code
Entry
Us e r - Pa s sw ord Default value is 044444.
SEtUp To set the Master Password. Valid for all Password protected entries.
Default value is 055555.
M aste r- P a ssw or d
Init il To Initialise the Bill Title Header & Footer to default values
This menu will not be displayed if “Single Touch” mode is selected
Init T itl e Hd &Ft
under COM-1 Mode.
System will ask for Confirmation to Initialise. Press Y key for YES &
N key (or) ESC key for NO (Not to Initialise).
Version 1.0.6 - 15 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
P rin t Bil l - Si ngl e Select Weighing Bill to Print in Full bill Format (1) or Single Line
1 (0).
Default is 0 – Full Bill Format.
Version 1.0.6 - 17 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
S EtU P To edit the Printing Summary Format of Line -1 & Line 2 and also edit
Single Line Bill Format
Ed it Su m& S.L in e
Summary Format is common for all type of reports like Header1 Wise,
Header1 with Date Wise, All Summary, Data Wise Only, Code Wise
Su mm Lin e - 1 00 5 Only, Code with Date Wise Summary Report.
/S L/ / DT // H 1/ /C 1/ / This menu will not be displayed if “Single Touch” mode is selected
under COM-1 Mode.
Note :
While using the Bill Symbol there should be Backward slash („/‟)
before and after each bill symbol. In Edit Print bill mode, at the end of
the each line there should be closing square barket „] ‟.
To edit the single line Bill Format to print at Vehicle Entry & Vehicle
S. Lin e B il l 00 3
Re Entry (F1 & F4 Key operation). (For Code Details refer Bill Code
/S L/ /DT //T M //H 1/ /
details).
P rnb iL Here to Edit, Print, Load default bill, Initialize, Download & enter
Number of Print Bill Line the Weighment Bill Format.
Ed it Pr int L dbi l
Maximum 20 lines and each line contain 90 characters.
In it Dl oad N Lin e
Press ‘E’ Key to Edit the Weighment Bill .
i. The Line number can be selected with UP or DOWN arrow key.
PB il Lin e: 1 , 00 5 ii. Press ENTER key to select to edit the Line.
T ruc kNu mb e r: / H1 /
iii. Selection of character position in the line is through LEFT or
RIGHT Arrow keys.
iv. After editing each Line press ENTER key to store.
Press ‘P’ Key to Print the Weighment Bill.
i. Here user can check the bill alignment and bill format.
Version 1.0.6 - 18 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
CO M Conn . F AI L e) If the system had not get the reply then system will display as
w ith Co mput e r " COM Conn. FAIL “, “ with Computer " and return to edit mode,
now check, COM cable or baudrate setting and try again for
download.
This menu will not be displayed if “Single Touch” mode is selected
under COM-1 Mode.
No. O f Lin e s Bi ll Press „N‟ key to Enter the Number of Print bill lines. Entry allowable
24 is 01 to 99.
This menu will not be displayed if “Single Touch” mode is selected
under COM-1 Mode.
Version 1.0.6 - 19 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
9. Diagnostic
System shows
tes t
Press ENTER Key to Select option in the Diagnostic.
* Diagnostic *
Version 1.0.6 - 20 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
8.8.8.8.8.8. In this menu all the segments and dots of the LED & LCD display are
energized for Visual inspection. Press ESC Key returns from this
▒▒▒▒▒▒▒▒▒ option.
▒▒▒▒▒▒▒▒▒
▒▒▒▒
Version 1.0.6 - 21 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Check - KEYPAD Press MENU/ESC key to come out from the function.
x. Restore - Calibration
tes t Here to Restore the Calibration, this may be useful when the system
is loaded with default value, then restore the calibration data.
Restore – Calib? If the menu is selected the system will ask for confirmation to
restore the calibration data.
Press Enter Key to select.
tes t
Now system load the factory set values to calibration, System Setup
parameters.
Are you sure to
Load Defaults? After loading the default values, system will display “ loaded”, and
will restart the System.
xi. GPRS Comm Check
Press Enter Key to enter into GPRS Comm Check menu.
tes t
This facility will work only if the “GPRS Module” enabled in “EntryBill -
Config” menu. Else it will display “GPRS Module Disabled” whenever
GPRS Comm Check
user press Enter key.
When user presses enter key, query will send to the GP RS Module. If
the response received from GPRS module then it will display
“MODULE COMM OK”.
Till the response received from Module it will display “Waiting for
Resp”.
If the response not received for a particular time it shows
“Timeout!!!””Check Comm” message will be displayed.
xi. Delete all Msg
Press Enter Key to enter into Delete all Msg menu.
tes t
This menu used to delete all messages which are stored in SIM
memory.
Delete all Msg
This facility will work only if the “GPRS Module” enabled in “EntryBill-
Config” menu. Else it will display “GPRS Module Disabled”
whenever user presses Enter key.
All message delete query will send to the GPRS Module. If the
response received from GPRS module then it will display “ Message
Deleted”.
If the response not received for a particular time it shows
“Timeout!!!””Try Again” message will be displayed.
Version 1.0.6 - 22 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
System has the capability of storing the following for every record: -
1. Title Header1
System allows 12 digit alphanumeric characters. If vehicle re -
entry based on vehicle number, by default system treat this
header1 as Vehicle number. This entry is must.
6. Date & Time System stores separate date & time for Gross & Tare.
Option 1 to 6 will vary depending upon customer requirement. So, user can configure these
options either enable or skipping independently for Vehicle entry (F1 Key) and Vehicle re -entry
(F4 Key) by weigh 100 itself or through PC.
For Option 1 to 3, user can define his own header name in 12 digit alphanumeric character.
eg. For header1 name, we can configure as “VEHICLE NO.” or “TRUCK NUMBER” depending
upon customer‟s requirement.
Manual gross weight or Manual tare weight entry during vehicle entry option.
User can configure his weighbridge name and address in 3 lines (In Setup menu -> Edit Bill
Title), the Summary Report & Single Line Bill printing format for i. Date Wise, ii. Code Wise, iii.
Code with Date Wise, iv. Header-1, v. Header-1 with Date Wise and vii. All Summary report can
be configured. (In Setup menu -> Entry Bill - Config).
Version 1.0.6 - 23 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
F9 Key Truck Wise & Truck with Date Wise Summary Report
F11 Key Gunny Weight (It will available if the Gunny Wt enabled in EntryBill -Config)
Note:
If the COM-1 mode is PC, F1-F11 key functions will not work. Still F12 can be accessible for
menu operation.
Before storing the record, user should configure the requirements in
Setup Menu -> Entry Bill – Config.
11.1. F1 Key: Vehicle Entry
System Shows
V EH IC L E ENT RY Press ENTER Key to Select the Vehicle Entry Process or ESC key to exit this
Bil l Nu mb er : 1 23 process. Now system will display the current Bill Number.
Version 1.0.6 - 24 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
15 6 .7 0 Here to enter the Weight as manual in number. If invalid weight is entered then
MANUALENTRY Y/N system shows “ Invalid Weight”.
(Tare) The manual weight can be configured in Setup -> EntryBill - Config.
G-Gross, T-Tare and N-Nil (Nil : Disable Manual Weight Entry).
T AR E W EIG HT :
07 5 00 Y (Yes) key for entry the Manual weight in 5-digit Numeric value
N (No) key for exit from manual weight entry and system will ask whether
G RO S S =G T AR E =T current is to taken as Gross (G) (or) Tare (T) weight.
Hint : Tare Weight should be less than Gross Weight.
Customer No - 1 If the “GPRS Module” enabled in “COM-2 Prot set” system will ask the
“Customer No-1” and “Customer No-2”.
Customer No - 2
Refer section “12.5. SMS Facility” for more details.
S AV E R E C O R D Y / N
Now system will ask whether to store the current record. Press Y key (Yes) to
Gross Weight
store (or) N / ESC Key to exit from Vehicle Entry without save the record.
If Y key (YES) then system will store the current record (at the time of Y key is
pressed the weight displayed, current time and date will be stored).
If N / ESC key is pressed the system shows “ RECORD NOT SAVED “.
PRINT RECORD Y/N
Now will system show “PRINT RECORD Y/N”. Press Y key (Yes) for print record
(or) N key (No) for skip prints.
System show “ RE-PRINT Y/N “, whether again to print the record, press Y key
to print again and N key to skip the print.
While exit from Vehicle entry after saving the record, system will show
“VECHICLE ENTRY “, “ OVER “, if exit before saving system will show
“VECHICLE ENTRY “, “ CANCELLED “.
Version 1.0.6 - 25 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
r EC ALL Here to recall the record through Bill No, enter the bill number in 3
digit with leading zero and press ENTER Key.
ENT ER B ILL NO : If bill is available, then system prints that record, Otherwise system
03 0 shows error message as “BILL NOT AVAI” and if bill number is invalid
entry then system shows error message as “INVALID BILL NO”.
If there is no record “NO RECORD” message will be displayed.
11.3. F3 Key: Initialize
ini r EC Here to initialise the record.
This entry is protected by Master password, first system ask password
INIT I AL I S E Y / N if it is valid the ask confirmation (message as “INITIALISE Y/N “)
whether to initialise the record, for yes press Y key (or) to exit or
escape from this process press N key now system shows “ INIT –
RECORD”, ” CANCELLED” and return to Normal mode.
Hint : Confirm before initialise the record.
11.4. F4 Key: Here to Re-Enter the Vehicle Details if this entry is related to exciting
Vehicle Re entry record.
The Vehicle entry is based on Header -1 data (or) Bill Number (or)
both.
15 6 .7 0 If the Re-Entry is in Header-1 data, then enter the header-1 data and
press ENTER Key, now system checks with existing record, if
VEHICLEREENTRY
unavailable then system shows “ RECORD NOT AVAI” and exit to
Normal mode, if available, and then system shows “ BILL AVAILABLE”
and enter into Re-Entry Option.
If the Re-Entry is through Bill Number, then system will show “BILL No
“ now enter the 5 digit with leading zero, then system will check with
existing records, if unavailable then system shows “ RECORD NOT
AVAI” (or) if re-entry is over then system shows “ REENTRY OVER ”
(or) if bill number is invalid then “ INVALID NUMBER“ (or) if available
then system shows “ BILL AVAILABLE” and enter into Re-Entry Option.
If record is available then system check other headers if it is not
entered in Entry mode then it shows the Header-2 to Header-4 value.
System checks Code-1 to 4 if it is not entered in Entry mode then it is
asking the 2-digit numeric value (between 01 to 75) with Vehicle entry
G fo r G r sW eigh t data.
G The Re-Entry fields of Header-1 to 4, Code-1 to 4, Amount entries are
similarly to Vehicle Entry and all entries are configured in Setup Menu
Entry -> Bill Config.
System shows the Amount value in 3-digit numeric value (001 – 999).
If Gunny weight enabled, system asks “No of Bags” entry.
System will ask the customer phone number if “GPRS MODULE”
enabled in COM-2 Mode in settings. If the User don‟t want to send the
message to any number leave “0000000000” (country code (+91) not
needed - it will include automatically by the system) .
In vehicle entry, if gross weight is over, system shows “T for Tare
Weight” or if tare weight is over, system show “G for Gross Weight”.
Press „T‟ or „G‟.
System shows “SAVE RECORD Y/N”. Press „Y‟ for save record and „N‟
for exit from vehicle re-entry, system shows “Vehicle Re-Entry”,”
Cancelled!!!”.
In Setup if NoofBill is configured as „1‟, then system stores the record
Version 1.0.6 - 26 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
in same bill number. (So, both the entries is in same bill). If NoofBill is
„2‟, system stores the record in a last current record number.
Printing of bill is similar to Vehicle entry.
CODE & DATE WISE Here to print the Summary report of particular Code Header‟s Code
S U M M AR Y R E P O R T Number on particular date.
If any of the Code Header is disabled in Setup Menu -> EntryBill
Config, then if that code header is select for print , then system will
show the error message as “NOT APPLICABLE” and returns to Normal
Cod e1 - 1 /Co de 2 - 2 Mode.
Cod e3 - 3 /Co de 4 - 4
1. Select the Code Header Number (1 to 4).
DE ST I N. CO D E Select the Code Header‟s Code Details number (01 to 75). If there
03 is no record on this particular Code detail, then System shows
error message as “ No Record on “, ” this Code Number “.
ENT ER D AT E :
2. Now system will ask for particular record‟s date. (Enter the valid
15 / 08 /0 6
date and record available on the particular on that date).
3. Now system will print the Summary report .
Version 1.0.6 - 27 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
CODE - WISE
Here to print the Summary report of particular Code Header‟s Code
S U M M AR Y R E P O R T
Number.
If any of the Code Header is disabled in Setup Menu -> EntryBill
Cod e1 - 1 /Co de 2 - 2 Config, then if that code header is select for print, then system will
Cod e3 - 3 /Co de 4 - 4 show the error message as “NOT APPLICABLE” and returns to Normal
Mode.
IT EM CO D E
03 1. Select the Code Header Number (1 to 4).
2. Select the Code Header‟s Code Details number (01 to 75). If there is
no record on this particular Code detail, then System shows error
message as
“ No Record on “, ” this Code Number “.
Now system will print the Summary report of particular.
11.8. F8 Key: Data Wise & All Summary Report
S U M M AR Y R E P O R T Here to print the Summary report of all record (or) on particular date.
If „A‟ Key is pressed then system will print the record from Bill number 1
P re s s A – Al l R e c to current Record number.
D- D at e W is e R ec If „D‟ Key is pressed then system will ask for date as “ START DATE: “
and “END DATE:” .If the any record available in between start date and
ST ART D AT E : end date system will prints the records.
15 / 06 /1 8
If there is no record on the in between start date and end date, then
EN D D AT E : system shows “ No Record on”, ” this Date !!! ”.
15 / 06 /1 8 Now system will print the Summary report.
Version 1.0.6 - 28 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
11.9. F9 Key: Truck Wise & Truck with Data Wise Summary Report
T - T ruck W i se Here to print the Summary report of Truck wise & Truck with Date Wise
D – T ru c k & Da t e Report.
TRUCK WISE Press „T‟ Key to select the Truck Wise report and „D‟ key to Truck with
S U M M AR Y R E P O R T Date-Wise report.
In Truck Wise report, system will ask to enter the Truck Number
TRUCK NUMBER
TN 01A1234
(Header –1 data). Enter the valid Header –1 Data, and then system will
print report.
If the invalid Header-1 data is entered then system shows “RECORD
TRUCK& DATEWISE
NOT AVAL” and return to Normal mode.
S U M M AR Y R E P O R T
If „D‟ Key is pressed then system will ask Truck Number “TRUCK
TRUCK NUMBER NUMBER” first, then date as “ENTER DATE :“ (Enter the valid date and
TN 01A1234 record available on the particular on that date). If there is no record on
the particular date, then system shows “No Record on”,” this Date!!! ”.
ENT ER D AT E : Now system will print summary report of Truck Number on the
15 / 08 /0 6 particular date.
T AR E Y ES /N O Here to tare the current weight. System will ask for confirmation
S el ec t Y / N K e y whether to tare the current weight and show as “ TARE YES/NO”, ”
Press Y/N Key ”.
T arr ing . . . . . .
If tare the current weight press Y key ,now system shows “ Tarring ……”
and return to Normal mode (or) to cancel the tare operation press „N‟ or
„ESC‟ key, now system return to Normal mode.
11.11. F11 Key : Gunny Weight
We are getting gunny weight entry only in Kg. Total gunny weight will
G unn y W eig ht be calculated based on No of bags which is entered at the time Gross
10 . 00 0 weight.
This calculated weight subtracted from net weight.
If Gunny Weight needed, User has to enable Gunny Wt under Setup-
>EntryBill-Config->Gunny Wt (0-Disable, 1-Enable).
Version 1.0.6 - 29 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Note :
While using the Bill Symbol there should be Backward slash („ / ‟) before and after each bill symbol.
In Edit Print bill mode, at the end of the each line there should be closing square barket „ ] ‟. This
symbol is not used from Version 4.0.6 but if weight is manual is entered then „ * ‟ will print in
Weightment bill after the Manual Weight.
Version 1.0.6 - 30 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Version 1.0.6 - 31 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
Sample double line code wise summary report for the above summary format.
Version 1.0.6 - 32 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
To print Bill Title-1,Title-2, Title-3,Current Data & Time, Serial number, Header1, Header2,
Header3, Header4, Code1, Code2, Code3, Date, Gross weight, Tare weight, Nett weight and Amount.
Line – 1 : /SB//T1//EB//CR//SD//T2//ED//CR//SD//T3//CR//ED//CR/]
Line – 2 : DATE : /CD//S9//S9//S9//S9//S9/ TIME : /CT//CR/]
Line – 3 : ==============================================================
============/CR/]
Line – 4 : BILL NUMBER : /SL//CR/]
Line – 5 : TRUCK NUMBER : /H1//S9/ CUSTOMER NAME : /H2//CR/]
Line – 6 : DESTIN. NAME : /H3//S9/ MATERIAL NAME : /H4//CR/]
Line – 7 : MACHINE-1 NAME : /C1//S9/ MACHINE-1 NAME : /C2//CR/]
Line – 8 : MACHINE-3 NAME : /C3//S9/ MACHINE-4 NAME : /C4//CR/]
Line - 9 : GROSS WEIGHT : /SD//GW//ED/ /UN/ /GD/ /GT/ /CR/]
Line - 10 : TARE WEIGHT : /SD//TW//ED/ /UN/ /TD/ /TT/ /CR/]
Line - 11 : NETT WEIGHT : /S4//SD//NW//ED/ /UN/ /CR//CR/]
Line – 12 : ==========================================================
============/CR/]
Line – 13 : /F1//CR/]
Line – 14 : /EL/]
Line – 15 :
Version 1.0.6 - 33 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
ORIGINAL COPY
COMPUTERISED 100 TONNE WEIGH BRIDGE COMPUTERISED 100 TONNE WEIGH BRIDGE
Certified by the Dept. Of Legal Metrology, Govt. Of Tamil Nadu Certified by the Dept. Of Legal Metrology, Govt. Of Tamil Nadu
Bill No. : 786 Date: 07/03/18 Time: 06:24 Bill No. : 786 Date: 07/03/18 Time: 06:24
Truck Number TN01A1234 Truck Number TN01A1234
Customer Name ABC LTD. Customer Name ABC LTD.
Destination CHENNAI Destination CHENNAI
Material Name RICE Material Name RICE
Gross Weight 56780 Kg Gross Weight 56780 Kg
Tare Weight 8750 Kg Tare Weight 8750 Kg
Nett Weight 48030 Kg Nett Weight 48030 Kg
Tare Weight
24 HOURS SERIVCE Tare Weight
24 HOURS SERIVCE
Version 1.0.6 - 34 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
1000 Kg
EMPTY/LOAD
Note: In this report serial Number, date, time enabled. If any parameter disabled SPACE will printed.
12.6. SMS Facility
User can send the weigh Bill to the maximum of two customer Phone numbers. For this feature
GPRS Module needed. User has set “GPRS Module” under setup->COM-2 Prot set for enabling
this facility.
For sending this Weigh Bill to the customer, at the time of weighment entry system will ask 10
digit “Customer No-1”, “Customer No-2” if the “GPRS Module” enabled under setup->COM-2
Prot set.
Message needed for two numbers:
o If the User want to send the message to two numbers then enter the customer phone
number in the “Customer No-1”, “Customer No-2” entry.
Message needed for one number:
o If the User doesn‟t want to send the message to one number then leave “0000000000” in
the “Customer No-1” (or) “Customer No-2” entry.
o Note that if the user left one number as it is (“0000000000”) then that customer number
will ask at the Re-Entry time also. If the users want to send the message, then enter the
second number. Else leave as it is (“0000000000”).
Message Disable for the particular Bill:
o If the User don‟t want to send the message to any number leave “0000000000” in the
“Customer No-1”, “Customer No-2” entry.
Note:
No need to enter Country code (+91) for phone number - it will automatically include by the
system while sending a message.
12.5.1. Sample Weigh Bill:
Where,
Weigh Bill Device ID - Current Device ID
Device ID: 01 W.Name - Weigh bridge name
W.Name:Weigh B.No - Bill Number
bridge Name DATE - Weighment date
B.No: 10 TIME - Weighment time
DATE:16/02/2018 H1 - Header - 1
TIME:15:14:44 C1 - Code – 1
H1:TN01A1234 G.WT - Gross Weight
C1:RICE T.WT - Tare Weight
G.WT: 56780 Kg N.WT - Nett Weight
T.WT: 8750 Kg T.AMT - Tare Amount
N.WT: 48030 Kg G.AMT - Gross Amount
T.AMT: 0.00
G.AMT: 120.00
Version 1.0.6 - 35 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
13. Troubleshooting
Version 1.0.6 - 36 -
U s e r M a n u a l f o r A W EW 2 0 0 0 Intelligent Terminal
14. Annexure – I
14.1. Do’s
1. Please read the User Manual before using the AWEW 2000.
2. Ensure that the neutral – earth is less than 5 Volts AC, otherwise the board may get damaged.
3. Put your AWEW 2000 in a location with low humidity and a minimum of dust.
4. High temperature may cause problems.
5. Unplug the AWEW 2000 when it going to be left unused for an extended period of time.
6. Plug and unplug the peripheral (Keyboard, Transducer, Parallel printer, Com Cable) when the
AWEW 2000 is OFF state.
14.2. Don’ts
Don‟t expose your AWEW 2000 to direct excessive heat, moisture (or) dust.
Don‟t connect your AWEW 2000 to the same outlets of those of large inductive load.
Don‟t connect the power cable when your outlet v oltage does not match the AWEW 2000
rated, the rated voltage should be 24 VDC +/- 10%.
Don‟t Plug and unplug the peripheral when the AWEW 2000 is ON state.
Don‟t change the transducer connection (Refer the transducer connection details Section).
Version 1.0.6 - 37 -