You are on page 1of 33

1.

VarioPlus Industrial
2.
2. The
The low
low volume
volume and
and weight,
weight, versatile
versatile analyzer
analyzer

Compact
Compactand
andportable,
portable,ininaarugged
rugged
aluminium
aluminiumenclosure,
enclosure,for
forsemi-continuous
semi-continuous
emission,
emission,compliance
compliancetesting
testingand
andcontrol
control
measurement
measurementat atall
allcombustion
combustionsources
sources
3.
3. Standard
Standard features:
features:

Simultaneous
Simultaneousmeasurement
measurementof
ofup
upto
to99flue
fluegas
gascomponents
components

Standard
Standardanalysis
analysisof
ofOO22 ,,CO,
CO,flue
fluegas.temperature,
gas.temperature,combustion
combustionair
air
temperature
temperatureand
andstack
stackdraft
draft

Optional
Optionalanalysis
analysisof
ofNO,
NO,NO
NO22,,NO
NOxx,,SO
SO22,,HH22SS,,HC
HC,,CO
CO22,,HH22,,stack
stack
draft,
draft,gas
gasflow
flowvelocity
velocityand
andvolume
volumecalculation
calculation

Infrared
InfraredSO
SO22,,CO
CO,,CO
CO22,,CH
CH44measurement
measurement((optional
optionalNDIR
NDIRbench
bench))

Automatic
Automaticinternal
internaltest
testof
ofhard-
hard-and
andsoftware
softwarefunctions
functions
4.
4. Further
Further features
features

--standard
standarddata
datastorage
storagefor
for7.500
7.500emission
emissiontests
tests

--multi
multilanguage
languagesoftware,
software,user
userconfigurable
configurable

--suitable
suitablefor
forall
allfuel
fueltypes
typesand
andcombustion
combustionsources
sources

--self
selfchoose
choosefuels, variableOO22referencing
fuels,variable referencingfor
foremission
emissionreports
reports
--automatic
automaticCO
COsensor
sensorpurge
purgebybymeans
meansof ofsolenoid
solenoidvalve
valveand
andpurge
purge
pump,
pump,for
forsensor
sensorprotection
protectionatatvery
veryhigh
highCOCOconcentration
concentration

--continuous
continuousonline
onlinedata
datatransfer
transferto
toOnline
OnlineView
ViewPC
PCsoftware
software
5.
5. Measured
Measured components,
components, range,
range, accuracy
accuracy
6.
6. Combustion
Combustion calculations
calculations
7.
7. Large,
Large, backlit,
backlit, grafic
grafic type
type display,
display,
user
user friendly
friendly menu
menu guided
guided software
software
8.
8. Simultaneous
Simultaneous and
and continuous
continuous display
display of
of all
all
measurements,
measurements, user
user configurable
configurable display
display
9.
9. Automatic
Automatic interval
interval measurement,
measurement, for
for semi-
semi-
continuous
continuous measurement
measurement
9.0
9.0 Automatic
Automatic interval
interval measurement
measurement diagram
diagram
9.1
9.1 Complete
Complete gas
gas sample
sample conditioning
conditioning system
system
9.2
9.2 Application
Application optimized
optimized gas
gas sampling
sampling probe
probe tubes,
tubes,
different
different materials,
materials, max.
max. length
length of
of 2000mm
2000mm
9.3
9.3 Heated
Heated gas
gas sample
sample line,
line, probe
probe with
with heated
heated filter
filter

HEATED FILTER

HEATED SAMPLE
LINE

QUICK CONNECTOR
9.4
9.4 Heated
Heated filter
filter

FILTER

HEATING
9.5
9.5 Heated
Heated gas
gas sample
sample line
line
9.6
9.6 Sample
Sample conditioner
conditioner devices
devices

Integrated
Integratedsample
samplegas
gascooler
cooler

Solenoid
Solenoidvalve
valvefor
forautomatic
automaticzeroing
zeroing
9.7
9.7 Automatic
Automatic condensate
condensate draining,
draining, high
high vacuum
vacuum pump
pump

condensate
condensatepump
pump gas
gassampling
samplingpump
pump
9.8
9.8 Filtering
Filtering devices
devices

(*)
(*)

(*)
(*)

(*)
(*)PTFE
PTFEcoated
coated
10.
10. Analyzer
Analyzer gas
gas flow
flow schematic
schematic
10.1
10.1 Compact
Compact electrochemical
electrochemical sensor
sensor module
module

Maximum
Maximum installation
installation of
of 66 electrochemical
electrochemical cells
cells
10.2
10.2 Miniatuarized
Miniatuarized high-tech
high-tech NDIR
NDIRoptical
optical bench
bench
10.3
10.3 NDIR
NDIRoptical
optical bench
bench CO,
CO,CO
CO22,, SO
SO22
10.4
10.4 Inside
Inside view
view of
of open
open unit
unit
11.
11. User
User side
side of
of analyzer
analyzer

fast
fastthermal
thermalprinter
printerwith
witheasy
easypaper
paperloading
loading

8-channel
8-channelanalog
analogoutput
output44--20mA
20mA((option
option))

RS
RS232
232interface
interfacefor
forPC
PCdata
datavisualisation
visualisation
software
software((standard
standard))

Internal
Internal64(128)
64(128)MB
MBcard,
card,SD
SDor
orMMC
MMCfor
forhigh
high
volume data storage ( option
volume data storage ( option ))

RS
RS485
485interface
interfacefor
forconnection
connectionof
ofexternal
external
MRU
MRUtransmitter
transmitter((option
option))

PC
PCkeyboard
keyboardconnection
connection((option
option))

external
external12Vdc
12Vdcpower
powersupply
supply((standard
standard))

universal
universal90-240Vac
90-240Vacmains
mainspower
powersupply
supply
12.
12. Handheld
Handheld remote
remote control
control and
and display
display ,, over
over 20
20 m
m
RS232
RS232 connection
connection
13.
13. PC
PC data
data visualisation
visualisation software
software OnLine
OnLine View
View

E
x
p
o
r
t
to
E
X
E
L
13a.
13a. DATA
DATA TRANSMISSION
TRANSMISSION VIA
VIA RS232
RS232 // RS232
RS232 up
up to
to 20m
20m
13b.
13b. DATA
DATA TRANSMISSION
TRANSMISSION VIA
VIA RS
RS 232/USB
232/USB up
up to
to 20m
20m
13c.
13c. DATA
DATA TRANSMISSION
TRANSMISSION VIA
VIA RS485/RS232
RS485/RS232 up
up to
to 1.000m
1.000m
13d.
13d. DATA
DATA TRANSMISSION
TRANSMISSION VIA
VIA RS485/USB
RS485/USB up
up to
to 1.000m
1.000m
14.
14. Measuring
Measuring side
side of
of analyzer
analyzer

Draft
Draft inlet
inlet port
port
Diff.pressure
Diff.pressure inlet
inlet port
port
Electrical
Electrical connections
connections
AUX
AUX connector
connector for
for Sample
Sample gas
gas inlet
inlet port
port
NiCrNi,
NiCrNi, or
or 4-20mA,
4-20mA,
or
or 0-10V
0-10V (option)
(option) Filter
Filter
Condensate
Condensate outlet
outlet port
port
Combustion
Combustion air
air
Temperature
Temperature
(standard)
(standard)
15.
15. Pitot
Pitot tube
tube gas
gas flow
flow velocity
velocity measurement,
measurement,
with
with flow
flow volume
volume calculation
calculation
17.
17. Transport
Transport case
case

Standard soft case Optional hard case


with trolley & wheels