EMC Avamar Installation and

Configuration

Education Services
February 2009
EMC Avamar Installation and Configuration Lab Guide

Copyright

Copyright © 1996, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009 EMC Corporation. All Rights
Reserved.
EMC believes the information in this publication is accurate as of its publication date. The information is subject
to change without notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO
REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS
PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software
license.

EMC, ICDA® (Integrated Cached Disk Array), and EMC2® (the EMC logo), and Symmetrix®, are registered
trademarks of EMC Corporation. EMC™ and SRDF™ are trademarks of EMC Corporation.
All other trademarks used herein are the property of their respective owners.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 2 of 192
EMC Avamar Installation and Configuration Lab Guide

Trademark Information

EMC EMC2, EMC, Symmetrix, Celerra, CLARiiON, CLARalert, Connectrix, Dantz,


Trademarks Documentum, HighRoad, Legato, RepliStor, Navisphere, PowerPath, ResourcePak,
SnapView/IP, SRDF, TimeFinder, VisualSAN, and where information lives are
registered trademarks and EMC Automated Networked Storage, EMC
ControlCenter, EMC Developers Program, EMC OnCourse, EMC Proven, EMC
Snap, Access Logix, AutoAdvice, Automated Resource Manager, AutoSwap,
Avamar, Avamar, C-Clip, Celerra Replicator, Centera, CentraStar, CLARevent,
CopyCross, CopyPoint, DatabaseXtender, Direct Matrix, Direct Matrix
Architecture, EDM, E-Lab, Enginuity, FarPoint, FLARE, GeoSpan, InfoMover,
MirrorView, NetWin, OnAlert, OpenScale, Powerlink, PowerVolume, RepliCare,
SafeLine, SAN Architect, SAN Copy, SAN Manager, SDMS, SnapSure, SnapView,
StorageScope, SupportMate, SymmAPI, SymmEnabler, Symmetrix DMX,
Universal Data Tone, and VisualSRM are trademarks of EMC Corporation. All
other trademarks used herein are the property of their respective owners.

Third Party AIX is a registered trademark of International Business Machines Corporation.


Trademarks Brocade, SilkWorm, SilkWorm Express, and the Brocade logo are trademarks or
registered trademarks of Brocade Communications Systems, Inc., in the United
States and/or in other countries. Compaq and the names of Compaq products
referenced herein are either trademarks and/or service marks or registered
trademarks and/or service marks of Compaq. Hewlett-Packard, HP, HP-UX,
OpenView, and OmniBack are trademarks, or registered trademarks of Hewlett-
Packard Company. McDATA, the McDATA logo, and ES-2500 are registered
trademarks of McDATA Corporation. Microsoft, windows, and windows NT are
either registered trademarks or trademarks of Microsoft Corporation in the United
States and/or other countries. NobleNet is a registered trademark of Rogue Wave
Software, Inc. SANbox is a trademark of QLogic Corporation. Sun, Sun
Microsystems, the Sun Logo, SunOS and all Sun-based trademarks and logos, Java,
the Java Coffee Cup Logo, and all Java-based trademarks and logos, Solaris, and
NFS, are trademarks or registered trademarks of Sun Microsystems, Inc. in the
United States and other countries. UNIX is a registered trademark of The Open
Group.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 3 of 192
EMC Avamar Installation and Configuration Lab Guide

Document Revision History

Rev # File Name Date


A EMC Avamar Installation and October 2007
Configuration Lab Guide
B EMC Avamar Installation and September 2008
Configuration Lab Guide (4.0.x)
C EMC Avamar Installation and February 2009
Configuration Lab Guide (4.1.x)

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 4 of 192
EMC Avamar Installation and Configuration Lab Guide

Table of Contents: EMC Avamar Installation and Configuration


Lab Guide

Copyright .........................................................................................................................2
Trademark Information.....................................................................................................3
Document Revision History..............................................................................................4
Table of Contents: EMC Avamar Installation and Configuration Lab Guide....................5
EMC Avamar Installation and Configuration Lab Guide .........................................................6
Lab Exercise 3-1: Single Node Avamar Install .......................................................................7
Lab Exercise 3-1 Part 1: Install Operating System ..........................................................8
Lab Exercise 3-1 Part 2: Node Preparation ..................................................................14
Lab Exercise 3-1 Part 3: Configure Network Settings ...................................................21
Lab Exercise 3-1 Part 4: Server Software Installation and Configuration......................37
Lab Exercise 3-1 Part 5: Backup Configuration Files....................................................46
Lab Exercise 3-2: Backup and Restore on a Single Node Avamar Server...........................53
Lab Exercise 3-2 Part 1: Install the Avamar Management Console..............................54
Lab Exercise 3-2 Part 2: Install the Avamar Client........................................................60
Lab Exercise 3-2 Part 3: Enable/Verify the Email Home Feature .................................64
Lab Exercise 3-2 Part 4: Licensing ...............................................................................75
Lab Exercise 3-2 Part 5: Perform a Server-Initiated Backup of Data on the Avamar
Client..............................................................................................................................81
Lab Exercise 3-2 Part 6: Perform a Restore of Data Deleted from the Avamar Client..87
Lab Exercise 3-3: Installation and Configuration of a Multi-Node Avamar Server (1X4) .....95
Lab Exercise 3-3 Part 1: Hosts Preparation and Network Configuration.......................97
Lab Exercise 3-3 Part 2: Avamar Multi-Node (1X4) Software Installation and
Configuration ...............................................................................................................129
Lab Exercise 3-4: The Mapall Utility ...................................................................................135
Lab Exercise 3-4 Part 1: Loading admin SSH Keys....................................................136
Lab Exercise 3-4 Part 2: Using Mapall with admin SSH Keys Loaded........................138
Lab Exercise 3-4 Part 3: Loading dpn SSH Keys .......................................................142
Lab Exercise 3-5: Perform Backup to a Multi-Node Avamar Server...................................145
Lab Exercise 3-5 Part 1: Perform Backup to a Multi-Node Avamar Server.................146
Lab Exercise 4-1: Node Replacement................................................................................151
Lab Exercise 4-1 Part 1: Fail a node...........................................................................153
Lab Exercise 4-1 Part 2: Perform Recovery When Avamar Server is Running in
Degraded Mode ...........................................................................................................158
Lab Exercise 4-1 Part 3: Perform Node Replacement ................................................163
Lab Exercise 5-1: Node Addition ........................................................................................175
Lab Exercise 5-1 Part 1: Perform Node Addition ........................................................177

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 5 of 192
EMC Avamar Installation and Configuration Lab Guide

EMC Avamar Installation and Configuration Lab Guide

Introduction The lab exercises contained in this guide will give you an
opportunity to reinforce the information that you are learning in the
EMC Avamar Installation and Configuration course. The lab
exercises are designed to be run in a test lab environment on the
Avamar test lab systems as described below. Some of the lab
exercises may make changes to the system. For this reason, do
NOT attempt to run the lab exercises on any production system.

You will be using a Virtual Data Center (VDC) environment to


Avamar Test Lab perform the EMC Avamar Installation and Configuration course
Description: lab exercises.

At the start of the first lab, the instructor will provide each student
with a reference sheet containing host names, IP addresses,
login, and other information needed to complete the lab exercises.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 6 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-1: Single Node Avamar Install

Purpose: In this lab you will perform Avamar Installation on a single node

In this lab you will perform:


Objectives: ‰ Basic hardware configuration
‰ Install operating system
‰ Node preparation
‰ Configure network settings
‰ Server software installation and configuration

References: EMC Avamar Server Software Installation Manual

EMC Avamar Installation and Configuration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 7 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-1 Part 1: Install Operating System

Step Action
1 To access your system, open an Internet Explorer browser session from your
classroom laptop and enter the access URL (provided in your student handout).

Enter the Access Login and Password as indicated in your student handout and
click Login.

2 Click your Windows client (indicated in your student handout).

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 8 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Login to your system as administrator, password student.

4 Double-click the VMWare Virtual Infrastructure Client shortcut on the desktop.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 9 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Login to the Virtual Infrastructure Client with the following information:

Server: <hostname of your VMware Virtual Center Server>


Username: <VMWare userid>
Password: <VMWare password>

6 Press the Inventory button and select Virtual Machines and Templates.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 10 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 Expand the tree on the left-hand pane until your single-node Avamar server
appears. Select your single-node Avamar server by clicking on the server name.

8 Close the Getting Started tab. The following screen appears:

In the left pane, select <your Avamar single node server> and click the Power On

Icon to turn the machine on.

Click the Open Console Icon to bring up the console.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 11 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 The system is setup to boot from the Avamar Red Hat Linux ISO image. The
installation menu options screen appears.

Enter a2 as the installation option.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 12 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
10 Wait for the installation to complete and the following screen to appear.

11 Hit Enter to reboot the system.

End of Lab 3-1 Part 1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 13 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-1 Part 2: Node Preparation

Step Action
1 In your console, the following window appears:

Note: You may have to hit enter in the window to cause the login prompt to appear.

Enter the following to logon to the system:


login: root
password: changeme

2 To configure network settings for this host, type (all on one command line):

/usr/sbin/netconfig --ip=<IP Address of your host>


--netmask=<Subnet> --hostname=<hostname> --domain=avamar.lan
--device=eth0 --gateway=<gateway>

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 14 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 To restart the network service, type:

service network restart

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 15 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 To verify basic connectivity, type:

ping <IP Address of your host>


ping <IP address of your gateway>
ping <IP address of your DNS server>
ping <IP address of your secondary DNS server>

Validate that all four ping commands work.

Hit Ctrl^C to exit ping.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 16 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Note: In the classroom environment, it sometimes takes an inordinately long time to
perform the time synchronization step when installing Avamar. This is due to the way
timer interrupts are simulated and handled by VMware. This solution involves
changes to the /boot/grub/grub.conf file. This step is to be performed in the
classroom only and NOT in a production environment.

To transfer the grub.conf file to the host, double click the WinSCP icon on your
desktop.

Result: The WinSCP Login screen appears.

Select root@<your hostname> and click Login.

Accept any warnings and proceed.

If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 17 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 The following screen appears:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 18 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 On the left pane, navigate to
C:\Documents and Settings\Administrator\My Documents

On the right pane, navigate to /boot/grub

8 Copy the grub.conf file from the Windows directory to the /boot/grub directory
on the server. When the following screen appears, select Copy.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 19 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 Click Yes to overwrite the file.

10 Exit from the WinSCP session by closing the application.

11 Restart your host by typing:

reboot

Wait for the reboot to succeed.

Close the VMware console window and the VMware Virtual Infrastructure window.

You have now configured basic networking for your host so you can access this host
remotely using a program such as PuTTY.

End of Lab 3-1 Part 2.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 20 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-1 Part 3: Configure Network Settings

Step Action
1 To transfer the Avamar software to the host, double-click the WinSCP shortcut on your
desktop.

Result: The WinSCP Login screen appears.

Select root@<your hostname> and click Login.

Accept any warnings and proceed.

If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 21 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 The following screen appears:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 22 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 On the left pane, navigate to the Z:\ drive.

On the right pane, navigate to /usr/local/avamar/src.

Copy the Avamar Software tar file to the /usr/local/avamar/src directory on the
server. The following screen appears:

Click Copy to copy the file.


Close the WinSCP session.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 23 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Open a PuTTY SSH session to your Avamar single node server by clicking the
PuTTY icon on your desktop.

Result: The following Window appears:

Select <your Avamar single node host> and click Load and Open.

login: root
password: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 24 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Change directories by typing:

cd /usr/local/avamar/src

6 To extract dpnutils and dpnnetutil, type:

tar xzvf <name of tar file> RHEL4_64/{dpnutils,dpnnetutil}'*'

7 To install dpnutils and dpnnetutil, type:

rpm -ivh RHEL4_64/{dpnutils*,dpnnetutil*}.rpm

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 25 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 To create a temporary probe.out file, type:

su - admin
cd /usr/local/avamar/var
probesingle <IP address of your single node server>

9 To ensure that the single node server responds to the root user:

First, exit out of the admin user shell to return to the root shell, type:

exit

Then, from the root shell, type:

ssh-agent bash
ssh-add ~dpn/.ssh/dpnid
export SYSPROBEUSER=root

Type:

mapall --all date

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 26 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
10 To launch the network configuration utility, type:

dpnnetutil

11 The following screen appears:

Select Yes.

12 The following screen appears:

Enter/verify the IP address of your single node server. Hit <TAB> and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 27 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
13 The following screen appears:

Enter the hostname of your single node server and click OK.

Note: Check the name of your hostname! It should not begin with "avamar".

14 The following screen appears:

Enter avamar.lan as the parent domain and click OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 28 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
15 The following screen appears:

Enter the <IP Address of your primary DNS Server> and select OK.

16 The following screen appears:

Enter the <IP Address of your secondary DNS Server> and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 29 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
17 The following screen appears:

Enter/verify the network mask and select OK.

18 The following screen appears:

Enter/verify the default network gateway and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 30 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
19 The following screen appears:

Select Yes to accept the settings.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 31 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
20 The following screen appears:

Select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 32 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
21 Type: tail -f /usr/local/avamar/var/log/dpnnetutil.log

Verify that no errors occurred.

Hit Ctrl-C to exit tail –f.

22 Type, exit to exit from the session.

Close your PuTTY window, if still open.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 33 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
23 Add the checkfs-tweaks.pl file to the server. On your Windows desktop, click
the WinSCP icon.

Select admin@<your single node server> and click Login.

If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 34 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
24 On the left pane, navigate to
C:\Documents and Settings\Administrator\My Documents.

On the right pane, navigate to /data01/home/admin.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 35 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
25 Copy the checkfs-tweaks.pl file. Select Copy to confirm copying the file.

Note: The checkfs.tweaks.pl file allows us to override the minimum LUN size
requirements of Avamar. This option is not supported in production environments
and is only used for lab or test systems.

26 Exit from the WinSCP session by closing the application.

End of Lab 3-1 Part 3.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 36 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-1 Part 4: Server Software Installation and


Configuration

Step Action
1 Open an SSH connection to your host using PuTTY (Click the PuTTY icon on your
desktop).

Select <your single node server> and click Open. Accept any security warnings and
continue.

Login using the following values:

Login: root
Password: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 37 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Change directory to /usr/local/avamar/src by typing:

cd /usr/local/avamar/src

3 Extract the dpnavqinstall package. Type:


tar xzvf <Name of tar file> RHEL4_64/dpnavqinstall'*'.noarch.rpm

4 Install dpnavqinstall. Type:

rpm -ivh RHEL4_64/dpnavqinstall*.rpm

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 38 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Set up the install configuration file.

Edit the file, /usr/local/avamar/var/install.conf. Substitute the values


from your student handout sheet for the values after the equal sign.

Set the following values:

gsan_key_account_id=<Your customer number>

gsan_key_asset_reference_id=<Your asset number>

local_time_zone=<Your time zone>

time_servers=<time_server_1,time_server_2>

Note: Remember to remove the leading pound sign (#) from the above lines.
Specify both NTP servers separated by a comma. Do not use spaces to separate the
NTP server names.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 39 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 Start the software installation by entering the command:

avqinstall

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 40 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 To monitor the installation open a new PuTTY session and tail the
/usr/local/avamar/var/log/avqinstall.log file. Type:

tail –f /usr/local/avamar/var/log/avqinstall.log

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 41 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 From time to time messages will appear inviting you to tail another log file. Tail
these files to observe progress of individual tasks.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 42 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 Wait until the original avqinstall command completes. Check for any error
messages.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 43 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
10 To get the status of the Avamar server, type:

dpnctl status

Note that the Scheduler status is down.

11 To start the scheduler, type:

dpnctl start sched

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 44 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
12 To verify the scheduler status, type:

dpnctl status

End of Lab 3-1 Part 4.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 45 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-1 Part 5: Backup Configuration Files

Step Action
1 It is strongly recommended to backup all configuration files, to be used in case of a
utility node failure.

To do this, in the PuTTY session logged in as root open from the previous lab,
type:

cd /root

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 46 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 To run the backup script, type:

/usr/local/avamar/bin/backup_upgrade_files

Note: The backup_upgrade_files script will return an error for backing up


replication information since replication is not setup on this server. It is safe to ignore
this error in this case.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 47 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Type:

cd /tmp

To view the backup directory, type:

ls

Note the name of the backup directory (It will be in the format “backups_date_time”)

File Name: __________________________

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 48 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Type:

tar czvf <name of backup directory>.tgz <name of backup


directory>/

5 Type:

ls

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 49 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 To copy the file to your Windows host, launch WinSCP by clicking the WinSCP
icon on your assigned Windows machine’s desktop.

Select root@<your single node server> and click Login.

If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 50 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 On the left pane, navigate to
C:\Documents and Settings\Administrator\My Documents.

On the right pane, navigate to /tmp.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 51 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 Copy the <backup_date_time>.tgz file.

Select Copy to confirm copying the file.

9 Close your WinSCP session.

End of Lab 3-1 Part 5.

End of Lab 3-1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 52 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2: Backup and Restore on a Single Node


Avamar Server

Purpose: In this lab you will perform a server-initiated backup and restore of
a client to/from your single node Avamar server.

In this lab you will perform:


Objectives:
‰ Avamar Management Console installation
‰ Avamar Client installation
‰ Server-initiated backup
‰ Server-initiated restore

References: EMC Avamar Installation and Configuration Student Guide

EMC Avamar Administration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 53 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2 Part 1: Install the Avamar Management


Console

Step Action
1 Start an Internet Explorer browser session from your assigned Windows host and
enter the following: http://<Your Avamar server host name>

Answer Yes to any Security Alerts and proceed to the next step.

2 Do not attempt to login.

Click the Documents and Downloads link at the bottom of the window.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 54 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Under Downloads, click the appropriate operating system hyperlink for your client
computer.

For this lab, click the Microsoft Windows 2000, XP, 2003, Vista link under
Windows for x86 (32 bit).

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 55 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 To install the Avamar management console application, click
AvamarConsoleMultiple-windows-<Version>.exe.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 56 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Click Run to start the installation. Click Run to any Security Warnings.

6 Click Accept to accept the license terms.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 57 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 Click Install to accept the default value for the destination folder and install the
software.

8 Click No to decline viewing the release notes.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 58 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 The installation of the Avamar Console application is complete.

End of Lab 3-2 Part 1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 59 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2 Part 2: Install the Avamar Client

Step Action
1 In the Internet Explorer browser window from the previous lab, to install the Avamar
client, click the AvamarClient-windows-<version>.msi link.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 60 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Click Run. When the Security Warning displays, click Run.

3 Click Next.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 61 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Accept the license agreement and click Next.

5 Click Next to accept the default value for the destination folder.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 62 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 Click Install to install the software.

7 Click Finish to complete the installation.

End of Lab 3-2 Part 2.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 63 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2 Part 3: Enable/Verify the Email Home Feature

Step Action
1 When fully configured and enabled, the “email home” feature automatically emails the
following information to EMC Technical Support twice daily:
• Status of the daily data integrity check
• Selected Avamar server warnings and information messages
• Any Avamar server errors
• Any RAID errors (single-node servers only)

To specify an SMTP server and a sender email address, you need to update the
mcserver.xml file located at /data01/avamar/var/mc/server_data/prefs
on the Avamar server.

Click the PuTTY icon on your desktop.

Select <your single node Avamar server> and click Open.

Login as user root and password changeme.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 64 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Type:

cd /data01/avamar/var/mc/server_data/prefs

3 Type: ls

The mcserver.xml file is listed

4 Edit the file mcserver.xml.

Find the <node name =”mail”> entry.

For the smtpHost field, enter: <your email server>


For the admin_mail_sender_address field, enter: avamar@avamar.lan

Result:

Save the file and exit the editor program.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 65 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Stop and re-start the Avamar MCS server software by entering the following
commands:

dpnctl stop mcs

dpnctl start mcs

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 66 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 To start the Avamar Administrator in Windows, click the Avamar Administrator
shortcut on the desktop or from the Windows Start menu.

Enter the following information:

User Name: MCUser


Password: MCUser1
Domain Name: /
Administrator Server: <Hostname of your Avamar Server>

Then, click Log On. Accept any JRE warnings.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 67 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 Click Administration.

8 Choose Tools > Manage Profiles from the menu bar.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 68 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 Create a copy of the existing High Priority Events profile by selecting it and clicking
Copy.

In the Save as field, enter: <Your Avamar Server Name>_HighProfileEvents. Click


OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 69 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
10 Select your newly created profile and click Enable. Select Yes to confirm.

Result:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 70 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
11 Select your newly created profile and click Edit. Click the Email Notification tab and
verify the Subject Header and Recipient Email List fields. Then, click Send Email.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 71 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
12 Click OK to dismiss the dialog stating the email was accepted.

13 Click OK to close the Edit Profile dialog.

14 Click OK to close the Manage Profiles dialog.

15 Choose Tools > Manage Schedules from the Avamar Administrator main menu.

Result: The following dialog appears:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 72 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
16 Select the Notification Schedule and click Run Now.

17 Click OK to close the Manage All Schedules dialog.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 73 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
18 Exit Avamar Administrator.

19 From the Windows Start menu, choose All Programs > Outlook Express.

Enter the password student and click OK.

20 You should receive one or more emails in your Inbox.

Click the Inbox and read and examine the email messages. These messages are the
type of messages that would be sent to EMC via the Email Home facility. EMC will
use these messages to monitor your Avamar servers.

When you are done examining the messages, quit Outlook Express.

End of Lab 3-2 Part 3.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 74 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2 Part 4: Licensing

Step Action
1 Open a PuTTY session to your single-node Avamar server.

Login as user admin with password changeme.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 75 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Enable SSH by entering the following commands:

ssh-agent bash
ssh-add ~admin/.ssh/admin_key

When prompted enter the passphrase: P3t3rPan

3 Enter: gathergsankeydata

Answer the prompts by supplying your Account ID and Asset Reference ID.
Accept the default for Internet Domain (avamar.lan).

Note: The Account ID begins with “CN-“; the Asset Reference ID begins with “A-“.

If you entered the values correctly, answer y when prompted. Otherwise, answer n
and try again.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 76 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Wait for the gathergsankeydata command to finish. Ignore the warnings that the
top-level domain is non-standard. Leave the PuTTY session active, you will need
it for a future step.

5 Open a WinSCP session and choose admin@<your single node Avamar server>.

Click Login. If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 77 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 On the left pane, navigate to the C:\My Documents\single directory. On the
right pane, navigate to the admin user home directory (data01/home/admin), if
not already there.

Copy the license.xml file to data01/home/admin.

7 When prompted, click Copy. Close the WinSCP session after copying the file.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 78 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 Return to your PuTTY session. Enter the command dpnctl status gsan to see
if the Avamar gsan server is running. It must be running in order to install the
license file.

9 Change the permissions of the license.xml file. Type:

chmod 644 license.xml

10 To install the license file, type:

avmaint license license.xml --avamaronly

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 79 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
11 Validate that the license was properly installed by issuing the command:

avmaint license --avamaronly

12 Close the PuTTY session.

End of Lab 3-2 Part 4.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 80 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2 Part 5: Perform a Server-Initiated Backup of


Data on the Avamar Client

Step Action
1 To start Avamar Administrator in Windows, click the Avamar Administrator
shortcut on the desktop or from the Windows Start menu.

Enter the following information:

User Name: MCUser


Password: MCUser1
Domain Name: /
Administrator Server: <Hostname of your Avamar Server>

Then, click Log On. Accept any JRE warnings.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 81 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 The Avamar Administrator menu appears. Click Administration.

3 Right click clients in the left-hand pane and select New Client.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 82 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Enter the following information

New Client Name: <Hostname of your client>


Contact: <Hostname of your client>

Click OK to add the client.

Click OK on the confirmation screen.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 83 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Expand the client tree in the left pane and right-click your client. Select Invite
Client. Click OK.

6 Click Backup & Restore from the main Avamar Administrator screen. (Or select
Navigation > Backup and Restore from the menu bar.)

Select your client from the tree structure in the left pane.

In the right pane, select Browse for Files, Folders or Directories and select the
C:\WINDOWS\Fonts directory.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 84 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 Select Actions > Backup Now from the menu bar. Select OK to begin the backup.

Select OK to confirm.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 85 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 Monitor the progress of the backup by clicking Navigation > Activity from the
menu bar. Verify that the backup was successfully completed.

End of Lab 3-2 Part 5.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 86 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-2 Part 6: Perform a Restore of Data Deleted from


the Avamar Client

Step Action
1 On your client machine, open Windows Explorer and navigate to
C:\WINDOWS\Fonts. Delete the ariblk.TTF file.

2 Launch Avamar Administrator. Click Backup & Restore.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 87 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Expand the clients tree in the left pane and select your client.

Click the Select for Restore tab in the right pane.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 88 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Select your backup and browse its contents. Select the ariblk.ttf file to restore.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 89 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Select Actions > Restore Now from the menu bar. Then, click OK to begin the
restore.

Click OK to confirm.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 90 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 Monitor the progress of the restore by clicking Navigation > Activity. Verify that the
restore completes successfully.

7 Verify that the ariblk.ttf file was restored by checking the contents of the
C:\WINDOWS\Fonts folder on your client.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 91 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 In this class, we will use the same Windows client for the multi-node install. We will
delete the client from the single node server before activating it with the multi-node
server.

To do this, select Navigation > Administration. Right click your client in the left pane
and select Delete Client.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 92 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 Click Yes to confirm that you want to delete the client.

Click Yes again to delete the client.

Click OK.

10 Exit Avamar Administrator.

End of Lab 3-2 Part 6.

End of Lab 3-2.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 93 of 192
EMC Avamar Installation and Configuration Lab Guide

This page left intentionally blank.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 94 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-3: Installation and Configuration of a


Multi-Node Avamar Server (1X4)

Purpose: In this lab you will install and configure a multi-node Avamar
server (1X4).

Objectives: This is a group LAB exercise.

In this lab, as a group, you will perform:

‰ Hosts preparation
‰ Avamar Multi-Node Installation and Configuration

References: EMC Avamar Server Software Installation Manual

EMC Avamar Installation and Configuration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 95 of 192
EMC Avamar Installation and Configuration Lab Guide

Desired Architecture

HOST 1 HOST 2 HOST 3 HOST 4 HOST 5 HOST 6

Avamar Avamar Data Avamar Data Avamar Data Avamar Data Avamar Data
Utility Node Node Node Node Node Node
(Spare)

Avamar 1X4 Server Configuration

Lab Overview

This is a group lab exercise. In this lab, you will build a multi-node Avamar (1X4) RAIN
server. Your instructor will assign you to groups to perform the lab.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 96 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-3 Part 1: Hosts Preparation and Network


Configuration

Step Action
1 To copy the Avamar software to the utility node, click the WinSCP icon on your
assigned Windows host’s desktop.

Select root@<your utility node> and click Login. Accept any warnings and
continue.

If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 97 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 On the left pane, navigate to the Z:\ drive.

On the right pane, navigate to /usr/local/avamar/src.

3 Copy the Avamar software file to /usr/local/avamar/src on the utility node.


Click Copy.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 98 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 After the file has been copied, exit from WinSCP.

5 To copy the checkfs-tweaks.pl file to your utility node, click the WinSCP icon on
your desktop.

Select admin@<utility node> and click Login. Accept any warnings and continue.

If prompted for a password, enter: changeme

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 99 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 On the left pane, navigate to the C:\Documents and
Settings\Administrator\My Documents folder.

On the right pane, navigate to /home/admin.

7 Copy the checkfs-tweaks.pl file to the /home/admin folder on the utility node.
Click Copy.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 100 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 After the file has been copied, exit WinSCP.

9 Click the PuTTY icon on your desktop.

Select <your utility node> and click Open. Accept any warnings.

Login as root, and password changeme.

10 Type: cd /usr/local/avamar/src

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 101 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
11 Extract two files from the Avamar software tar file:

tar xzvf <Avamar software file> RHEL4_64/{dpnutils,dpnnetutil}’*’

12 Install the two software packages using the Redhat Package Manager:

rpm -ivh RHEL4_64/{dpnutils*,dpnnetutil*}.rpm

13 Type su - admin

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 102 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
14 To create the probe.out file, edit /usr/local/avamar/var/probe.out

15 Edit the file as follows:

NONAT
<utility node name>:<utility node IP address>,<utility node IP
address>:<Data Node 1 IP address>,< Data Node 2 IP address>,<
Data Node 3 address>,< Data Node 4 IP address>,< Spare Node IP
address>

Save the file after making the required edits.

16 Type exit to logout of the admin shell.

17 Type:

ssh-agent bash
ssh-add ~dpn/.ssh/dpnid
export SYSPROBEUSER=root

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 103 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
18 To test TCP/IP connectivity to all nodes use the mapall command. Type:

mapall --all date

Verify that all nodes respond.

The following warning is normal as the hosts file will be updated by a future step.

WARNING: module id "av99-utility", found in


/usr/local/avamar/var/probe.out, line 2, did not resolve.

19 To launch the Avamar network definition utility type:

dpnnetutil

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 104 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
20 The following window appears:

Select No.

21 The following window appears:

Verify the IP address of your utility node. Hit <TAB> and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 105 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
22 Remove the spare node from your configuration. To do this, use the down arrow key
to select your spare node and press the space bar.

(‘x’ must appear before your spare node as shown below)

Select OK.

23 The following window appears. Leave it blank and click OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 106 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
24 The following window appears:

Click OK.

25 The following window appears:

Select Yes.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 107 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
26 The following window appears:

Leave it blank and select OK.

27 The following window appears:

Select Yes.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 108 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
28 The following window appears:

Leave it blank and select OK.

29 The following window appears:

Select Yes.

30 The following window appears:

Enter the <IP Address of your spare node> and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 109 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
31 The following window appears:

Leave it blank and select OK.

32 The following window appears:

Select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 110 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
33 The following window appears:

Select Yes.

34 The following window appears:

Verify your utility node address and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 111 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
35 The following window appears:

Enter your utility node hostname and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your hostname.

36 The following window appears:

Select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 112 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
37 The following window appears:

Enter the hostname and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your hostname.

38 The following window appears:

Verify the IP address and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 113 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
39 The following window appears:

Enter the hostname and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your hostname.

40 The following window appears:

Verify the IP address and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 114 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
41 The following window appears:

Enter the hostname and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your hostname.

42 The following window appears:

Verify the IP Address and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 115 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
43 The following window appears:

Enter the hostname and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your hostname.

44 The following window appears:

Verify the IP address and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 116 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
45 The following window appears:

Enter the hostname and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your hostname.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 117 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
46 The following window appears:

Enter avamar.lan and select OK.

WARNING: There is a default name in this field when the screen first displays.
Erase it entirely before entering your domain name.

47 The following window appears:

Enter <your First DNS server IP address>.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 118 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
48 The following window appears:

Enter <your second DNS server IP Address>.

49 The following window appears:

Verify the network mask and select OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 119 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
50 The following window appears:

Verify the gateway and select OK.

51 The following window appears:

Select No.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 120 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
52 The following window appears:

Select No.

53 The following window appears:

Select No.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 121 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
54 The following window appears:

Select No.

55 The following window appears:

Select No.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 122 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
56 The following window appears:

Select Yes.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 123 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
57 The following window appears:

Select OK.

58 Type tail -f /usr/local/avamar/var/log/dpnnetutil.log and check for


errors.

Hit Ctrl-C to exit tail –f.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 124 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
59 Type,

more /etc/hosts
more /usr/local/avamar/var/probe.out

Verify that the entries are accurate

60 To reboot the data nodes and the spare node, type:

mapall --parallel --bg reboot

ssh -f -x root@<IP address of Spare Node> 'reboot'

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 125 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
61 To reboot the utility node, type,

reboot

62 After your systems have rebooted, launch a PuTTY session and connect to your utility
node.

Login as root and password changeme.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 126 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
63 Type,

ssh-agent bash
ssh-add ~dpn/.ssh/dpnid
export SYSPROBEUSER=root

64 Type mapall --all date

Verify that all data nodes respond.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 127 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
65 To copy the checkfs-tweaks.pl file to all the nodes, type:

cd /home/admin

scp checkfs-tweaks.pl admin@<IP Address of Data Node 1>:/home/admin/


scp checkfs-tweaks.pl admin@<IP Address of Data Node 2>:/home/admin/

scp checkfs-tweaks.pl admin@<IP Address of Data Node 3>:/home/admin/

scp checkfs-tweaks.pl admin@<IP Address of Data Node 4>:/home/admin/


scp checkfs-tweaks.pl admin@<IP Address of Spare Node>:/home/admin/

End of Lab 3-3 Part 1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 128 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-3 Part 2: Avamar Multi-Node (1X4) Software


Installation and Configuration

Step Action
1 In your utility node PuTTY session, type:

cd /usr/local/avamar/src

2 To extract the dpnaqvinstall package, type:

tar xzvf <Avamar Software File Name> ‘RHEL4_64/dpnavqinstall*.rpm’

3 To install the dpnavqinstall package, type:

rpm -ivh RHEL4_64/dpnavqinstall*.rpm

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 129 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Edit the file, /usr/local/avamar/var/install.conf. Substitute the values
from your student handout sheet for the values after the equal sign.

Set the following values:

gsan_key_account_id=<Your customer number>

gsan_key_asset_reference_id=<Your asset number>

local_time_zone=<Your time zone>

time_servers=<time_server_1,time_server_2>

Note: Remember to remove the leading pound sign (#) from the above lines. Do not
use the same account id and reference id as the single node Avamar server. Your
handout sheet has a specific set of ids for the utility node. Specify both NTP servers
separated by a comma. Do not use spaces to separate the NTP server names.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 130 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Start the software installation by entering the command:

avqinstall

6 View the contents of the installation log by issuing the command:

tail –f /usr/local/avamar/var/log/avqinstall.log

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 131 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 From time to time you will be directed to run another tail command in another
window to see step-specific progress. Below is one example:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 132 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 Wait for the avqinstall program to finish. This will take from 30-60 minutes.
Check for any error messages.

9 To get the status of the Avamar server, type:

dpnctl status

Note that the Scheduler status is down.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 133 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
10 To start the scheduler, type:

dpnctl start sched

11 Type: nodenumbers

Study the output to see how physical and logical node numbers are represented on a
multi-node Avamar server.

12 Exit all open PuTTY sessions.

End of Lab 3-3 Part 2.

End of Lab 3-3.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 134 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-4: The Mapall Utility

Purpose: In this lab you will learn to use the mapall utility.

Objectives: In this lab you will:

‰ Load SSH keys


‰ Use the mapall command to perform various operations
on all the nodes in the Avamar server

References: EMC Avamar Installation and Configuration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 135 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-4 Part 1: Loading admin SSH Keys

Step Action
1 To open a PuTTY session to your utility node, click the PuTTY icon on your desktop.

Select your utility node and click Open.

Login as root and password changeme.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 136 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 To load the admin SSH keys, change user to admin by typing: su - admin

Then, type: ssh-agent bash


Next, type ssh-add ~/.ssh/admin_key
Pass Phrase: P3t3rPan

3 To check if the keys have been loaded into ssh-agent, type:

ssh-add -l

End of Lab 3-4 Part 1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 137 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-4 Part 2: Using Mapall with admin SSH Keys
Loaded

Step Action
1 Continuing from the previous lab, with admin keys loaded

Use mapall to report all hostnames.

Type: mapall --all ‘/bin/hostname’

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 138 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Use mapall to show the date on each node.

Type: mapall --all ‘/bin/date’

3 Use mapall to grep for the number of gsan processes.

Type: mapall --noerror ‘/bin/ps auxwm | grep gsan’

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 139 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Use mapall to grep for errors in the gsan log.

Type:

mapall --noerror ‘/bin/grep “ERROR|FATAL” /data01/cur/gsan.log’

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 140 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Use mapall to report file system disk space usage (in GB).

Type: mapall '/bin/df -h'

End of Lab 3-4 Part 2.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 141 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-4 Part 3: Loading dpn SSH Keys

Step Action
1 In your PuTTY session to the utility node, exit from the admin shell by typing exit
twice.

2 To run as user dpn on the utility node and as root on the storage nodes, load the
dpnid keys and export the variable SYSPROBEUSER=root.

To load the dpn SSH keys, change user to dpn by typing: su - dpn

Then type: ssh-agent bash


Next, type: ssh-add ~/.ssh/dpnid
Then type: export SYSPROBEUSER=root

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 142 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Use mapall to view the hosts file.

Type: mapall --all '/bin/cat /etc/hosts’

4 Exit the PuTTY session.

End of Lab 3-4 Part 3.

End of Lab 3-4.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 143 of 192
EMC Avamar Installation and Configuration Lab Guide

This page left intentionally blank.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 144 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-5: Perform Backup to a Multi-Node


Avamar Server

Purpose: Perform a backup to the multi-node Avamar server.

Objectives: In this lab you will

‰ Backup the C:\WINDOWS\Fonts folder to the multi-node Avamar


server

References: EMC Avamar Administration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 145 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 3-5 Part 1: Perform Backup to a Multi-Node


Avamar Server

Step Action
1 To activate your Avamar client with your new Avamar multi-node server, right click
the Avamar Client icon on your desktop taskbar and select Activate.

Enter the following information:

Administrator server address: <hostname of your utility node>


Client Domain: /

Then, click Activate.

Accept any warnings. Then, click OK.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 146 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 To start Avamar Administrator in Windows, click the Avamar Administrator
shortcut on the desktop or from the Windows Start menu.

Enter the following information:

User Name: MCUser


Password: MCUser1
Domain Name: /
Administrator Server: <Hostname of your Avamar Server Utility Node>

Then, click Log On. Accept any JRE warnings.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 147 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 The Avamar Administrator menu appears. Click Backup & Restore.

4 Select your client from the left pane. In the right pane, select Browse for Files,
Folders or Directories and select the C:\WINDOWS\Fonts directory.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 148 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Select Actions > Backup Now from the menu bar. Select OK to begin the backup.

Select OK to confirm.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 149 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
6 Monitor the progress of the backup by clicking Navigation > Activity from the
menu bar. Verify that the backup was successfully completed.

7 Exit Avamar Administrator.

End of Lab 3-5 Part 1.

End of Lab 3-5.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 150 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 4-1: Node Replacement

Purpose: In this lab, you will incorporate a ‘Spare’ storage node as an


active member of the Avamar server to replace a node that
‘failed’.

Objectives: In this lab you will

‰ ‘Fail’ a node
‰ Perform data recovery
‰ Decommission the failed node
‰ Add a replacement data node

References: EMC Avamar Installation and Configuration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 151 of 192
EMC Avamar Installation and Configuration Lab Guide

Desired Architecture

Simulate Host 5 failure.


Add Host 6 as a replacement node.

HOST 1 HOST 2 HOST 3 HOST 4 HOST 5 HOST 6

Avamar Utility Avamar Data Avamar Data Avamar Data Avamar Data Avamar Data
Node Node Node Node Node Node
(Spare Node)

Avamar Server

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 152 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 4-1 Part 1: Fail a node

Step Action
1 Open a PuTTY session to your utility node by clicking the PuTTY icon.

Login as user root with password: changeme.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 153 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Type: nodenumbers

3 Using the lab sheet provided by your instructor and the output of the nodenumbers
program, fill out the following table:

Utility Node Name (HOST1)


Utility Node IP address
Storage Node 1 IP address (HOST2)
Storage Node 2 IP address (HOST3)
Storage Node 3 IP address (HOST4)
Storage Node 4 IP address (HOST 5)
Spare Storage Node IP Address (HOST
6)
Logical node number of Storage node 4
(HOST 5)

4 Open a PuTTY session to storage node 4 (host 5) and login as user root
password: changeme.

5 Reboot the storage node, which will cause the node to fail. Type:

reboot

6 Close the PuTTY session to the storage node.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 154 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 To start Avamar Administrator in Windows, click the Avamar Administrator
shortcut on the desktop or from the Windows Start menu.

Enter the following information:

User Name: MCUser


Password: MCUser1
Domain Name: /
Administrator Server: <Hostname of your Avamar Utility Node>

Then, click Log On. Accept any JRE warnings.

Note: It may take several minutes for the log on; please be patient.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 155 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
8 You will see an Avamar Alert popup that informs you that a node has gone offline.
Click View Details.

Study the information in the Event Detail window. Then, click Close.

Click OK on the Avamar Alert popup to close the window.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 156 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 From the Avamar Administrator menu, click Server.

The following screen appears. Note that Node 0.3 is red (offline).

Close the Avamar Administrator Server window.

Close the Avamar Administrator menu.

End of Lab 4-1 Part 1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 157 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 4-1 Part 2: Perform Recovery When Avamar


Server is Running in Degraded Mode

Step Action
1 On your client machine, open Windows Explorer and navigate to
C:\WINDOWS\Fonts.

Delete the ariblk.TTF file.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 158 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
2 Launch Avamar Administrator. Click Backup & Restore.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 159 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Expand the tree in the left pane and select your client.

Click the Select for Restore tab in the right pane.

Browse through your backup and select the C:\WINDOWS\Fonts\ariblk.ttf file.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 160 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
4 Select Actions > Restore Now from the menu bar. Then, click OK to begin the
restore.

Click OK to confirm.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 161 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Monitor the progress of the restore by clicking Navigation > Activity. Verify that the
restore completes successfully.

6 Verify that the ariblk.ttf file was restored by checking the contents of the
C:\WINDOWS\Fonts folder on your client.

End of Lab 4-1 Part 2.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 162 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 4-1 Part 3: Perform Node Replacement

Step Action
1 Open a PuTTY session to your utility node and login as user root password
changeme.

Type: nodenumbers and study the output.

2 Using the lab sheet provided by your instructor and the output of the nodenumbers
program, fill out the following table

Utility Node Name (HOST1)


Utility Node IP address
Storage Node 1 IP address (HOST2)
Storage Node 2 IP address (HOST3)
Storage Node 3 IP address (HOST4)
Storage Node 4 IP address (HOST5)
Spare Node IP Address (HOST 6)
Logical node number of new Storage node
(HOST 6)

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 163 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 To see a list of checkpoints available, type: cplist

Ensure that a checkpoint that is acceptable as a suitable rollback point (if


required) exists and has been validated (hfs checked).

4 Next, change users to admin. Type:

su - admin

Load the admin SSH keys. Type:

ssh-agent bash
ssh-add ~/.ssh/admin_key
passphrase: P3t3rPan

Suspend all Avamar client activities. Type: avmaint suspend

Suspend all cron jobs. Type: suspend_crons

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 164 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Update the /usr/local/avamar/var/probe.out file using vi.

Replace the entry for the IP address of host 5 (failed node) with the IP address of
host 6 (spare node).

Save the file.

6 Exit out of the admin user shell (twice).

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 165 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 Change users to user dpn. Type:

su - dpn

Load the dpn SSH keys, type:

ssh-agent bash
ssh-add ~/.ssh/dpnid
export SYSPROBEUSER=root

8 To synchronize time on the new storage node, type:

asktime

Enter y to use the timeservers specified.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 166 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 Enter n to the question Do you have a dedicated Axion Subnet?

10 Enter y to use the previously specified time zone.

11 Enter y to configure the default set of nodes.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 167 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
12 Enter y to proceed with the installation.

13 Check the time displayed and confirm by entering y.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 168 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
14 Enter y to watch for time synchronization.

15 This next step takes about 10 minutes. After completion, enter y to see the results.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 169 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
16 Results:

17 Exit out of the dpn user shell (twice).

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 170 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
18 Change user to admin and load the admin SSH keys. Type:

su - admin
ssh-agent bash
ssh-add ~/.ssh/admin_key
passphrase: P3t3rPan

19 What is physical node number of the new node (host 6): __________________

What is Logical Node Number of the failed node (host 5): __________________

20 Note: This task must be performed as the admin user.

Rebuild the new node using the rebuild.node command. Type:

rebuild.node --nodes=<physical node number of new node> --


clean --tag=<logical node number of failed node>

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 171 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
21 Launch a new PuTTY session to your utility node and login as user root password
changeme.

Monitor the status of the new node by typing:

status.dpn <Number of seconds to refresh>

Ensure that the new node comes online.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 172 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
22 Go back to the SSH session running as the admin user and type: nodenumbers

23 In the PuTTY session to your utility node (host 1) logged on as root, monitor the
status of your nodes by typing:

status.dpn

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 173 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
24 Restart server operations and scheduled cron jobs. In the PuTTY session running
as the admin user, type:

avmaint resume
resume_crons

25 Exit all PuTTY sessions.

End of Lab 4-1 Part 3

End of Lab 4-1.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 174 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 5-1: Node Addition

Purpose: In this lab, you will add a new storage node as an active member
of the Avamar server.

Objectives: In this lab you will

‰ Add a new data node to your Avamar server

References: EMC Avamar Installation and Configuration Student Guide

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 175 of 192
EMC Avamar Installation and Configuration Lab Guide

Desired Architecture

Add old host 5 (which you failed earlier) as a new node to build an Avamar 1X5 server.

HOST 1 HOST 2 HOST 3 HOST 4 HOST 6 HOST 5

Avamar Avamar Data Avamar Data Avamar Data Avamar Data Avamar Data
Utility Node Node Node Node Node Node

Avamar 1 X5 Server Configuration

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 176 of 192
EMC Avamar Installation and Configuration Lab Guide

Lab Exercise 5-1 Part 1: Perform Node Addition

Step Action
1 Open a PuTTY session to your utility node and login as user root password:
changeme.

Type: nodenumbers and study the output.

2 Using the lab sheet provided by your instructor and the output of the nodenumbers
program, fill out the following table

Utility Node Name (HOST1)


Utility Node IP address
Storage Node 1 IP address (HOST2)
Storage Node 2 IP address (HOST3)
Storage Node 3 IP address (HOST 4)
Storage Node 4 IP address (HOST6)
New Storage Node IP Address (HOST 5 )
Logical node number of new Storage node
(HOST 5)

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 177 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
3 Return to the PuTTY session on your utility node.

Next, change users to admin. Type:

su - admin

Load the admin SSH keys. Type:

ssh-agent bash
ssh-add ~/.ssh/admin_key
passphrase: P3t3rPan

4 To see a list of checkpoints available, type cplist

Ensure that a checkpoint that is acceptable as a suitable rollback point (if


required) exists and has been validated (hfs checked).

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 178 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
5 Update the probe.out file with the IP address of the new node.

Append the IP address of host 5 to the end of the second line.

6 Exit out of the admin user shell (twice).

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 179 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
7 Change users to user dpn. Type:

su - dpn

Load the dpn SSH keys, type:

ssh-agent bash
ssh-add ~/.ssh/dpnid
export SYSPROBEUSER=root

8 To synchronize time on the new storage node, type:

asktime

Enter y to use the timeservers specified.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 180 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
9 Enter n to the question Do you have a dedicated Axion Subnet?

10 Enter y to use the previously specified time zone.

11 Enter y to configure the default set of nodes.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 181 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
12 Enter y to proceed with the installation.

13 Check the time displayed and confirm by entering y.

14 Enter y to watch for time synchronization.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 182 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
15 This next step takes about 10 minutes. After completion, enter y to see the results.

16 Results:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 183 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
17 Exit out of the dpn user shell (twice).

18 Change user to admin and load the admin SSH keys.

Type:

su - admin
ssh-agent bash
ssh-add ~/.ssh/admin_key
passphrase: P3t3rPan

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 184 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
19 Perform system quiescence. Type:

avmaint suspend

Type:

suspend_crons

20 What is physical node number of the new node (host 5): __________________

21 Note: This task must be performed as the admin user.

Start the new node using the start.nodes command. Type:

start.nodes --clean --nodes=<physical node number of new node>

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 185 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
22 Launch a new PuTTY session to your utility node and login as user root password
changeme.

Monitor the status of the new node by typing:

status.dpn <Number of seconds to refresh>

Ensure that the new node comes online.

23 To perform Avamar dynamic load balancing, go back to the PuTTY session on the
utility node where you are logged in as admin and type:

avmaint config balancemin=2 --avamaronly

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 186 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
24 Go back to the PuTTY session of your utility node where you are logged in as root.

Monitor the status of the balancing operation node by typing:

status.dpn <Number of seconds to refresh>

25 Notice changes in the utilization of each node.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 187 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
26 Turn off load balancing. Go back to the SSH session running as the admin user
and type:

avmaint config balancemin=0 --avamaronly

27 Restart server operations and scheduled cron jobs.

Type:

avmaint resume
resume_crons

28 Type: nodenumbers and study the output.

29 Exit all PuTTY sessions.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 188 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
30 Launch Avamar Administrator. Click Server.

Check the status of your Avamar server.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 189 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
31 Close all Avamar Administrator windows and exit Avamar Administrator.

32 In order to perform the EMC Avamar Administration class labs, you need to uninstall
Avamar Administrator and Avamar Client from your Windows host.

From the Windows Start menu, choose All Programs > avs > Administrator >
<version> > Uninstall Avamar Administrator.

33 Click OK to completely remove the Avamar Administrator Client:

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 190 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
34 To remove the Avamar Backup Client, use Windows Control Panel > Add or
Remove Programs. Find the Backup for Windows program and click Remove.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 191 of 192
EMC Avamar Installation and Configuration Lab Guide

Step Action
35 When asked if you are sure you want to remove the Backup for Windows program,
click Yes.

36 When the Backup for Windows program has been completely removed, close the
Add or Remove Programs window.

End of Lab 5-1 Part 1.

End of Lab 5-1.

End of Lab Exercises.

Copyright © 2009 EMC Corporation. All Rights Reserved. Version C Page 192 of 192