You are on page 1of 8
Date: 07 April 2022 To: SAIF POWERTEC LTD. Attn: Mr, Mahmudur Rahman Ref: CPA Project Enercon Quote: PG-2101-R3 Dear Sir, ENERCON ASIA PTE LTD 7 Mandai Link, Mandai Connection #09-18/19, Singapore 728653 TEL: 65-6565-5165 E-mail: sales@enercon-eng.com.sg Thank you very much for the opportunity to provide Enercon products and services. We are pleased to quote you the following: Corby DESCRIPTI Ground System 1 |- 1x Neutral grounding resistor |- 4x Neutral grounding switches (B) Master Control Panel | 1P3X Enclosure: 2100H x 8001V x 800D (mm) - ComAp Controller (Inteli Mains NTC BB & Inteli Vision 5) 1} ~ Siemens HMI (12” Touch) | - Siemens PLC (S7-1200 series CPU, 48 digital inputs, 32 digital outputs, 4 analog inputs) XW SINGAPORE USD 24,000 USD 20,000 (© Generator Control Panel IP3X Enclosure: 2100H x 800W x 800D (mm) - ComAp Controller (Inteli NTC BB & Inteli Vision 5) 4 |- Siemens HMI (12” Touch) - DEIF Differential Current Relay - Siemens PLC (S7-1200 series CPU ,16 digital inputs, 16 digital outputs, 4 analog inputs) USD 80,000 TOTAL _USD 124,000 DISCOUNT ~ USD 21,000 SELL USD 103,000 All equipment shall be export-boxed Approximate Ex-factory delivery shall be 12~ 16 weeks based upon receipt of your official purchase order or signed approval drawings, whichever occurs late. Payment Terms; Enercon Quote PG-2101-R3 Page 1 ~ BDT 20, 00,000/- (an equivalent amount of USD 23,000/-) to be paid to Enercon’s local office PG Controls Limited, Bangladesh in advance with the PO - Outstanding USD 80,000/- to be paid through an irrevocable LC issued to Enercon Asia Pte Ltd, Singapore Price shall be valid for fifteen (15) days. Invoice shall be issued based on ready to ship date. As always, should you need further clarification, please do not hesitate to contact us. Sincerely, For ENERGON ASIA PTE. LTD. ‘Name: Lim Mun Hey Operations Director M: +65-97891332 E: mhlim@enercon-eng.com.sg CLARIFICATIONS: (a) Cables for external connection outside Enercon panel shall not be included in this offer. (b) 230Vac supply shall be by others Enercon Quote PG-2101-R3 Page 2 Al. Bl. Neutral grounding system 4~ Single phase vacuum contactor 1 —Neutral grounding resistor (Stainless steel elements) System Voltage: 11000 Volts Line-to-Neutral Voltage: 6351 Volts Resistance: 317.5 Ohms (+10/-10%) ‘Current Ratings: 20 Amps Maximum Time On: 3 Seconds 4—CT, 205A, $P10, SVA with Earth Fault Relay Miscellaneous: 1 —Set of DIN rail mounted auxiliary relays, control wiring, terminal boards, MCB and nameplates Master Control Panel | Floorstanding cubicle, top entry control cables access, approximately 2100 mm high x 800 mm wide x 800 mm deep + Powder coated RAL 7035 light grey color + Enclosure: P42 + Material: 3.0mm thick steel plate + Finishing: Epoxy poweder coated + Panel light e/w door limit switch + 2x4" Fan @230Vac + Anti condensation heater c/w thermostat control @230Vae + Single socket outlet @230Vac + Service pocket mounted on back of the front door. 1 ~Mains Control Module — ComAp 112” Siemens HMI + Graphical representation of system status display + Electrical parameters monitoring (alarm & fault status) Digital Metering: 1 — Digital metering display shall include * Generator voltage * Bus voltage * Generator frequency + Power factor * Bus frequency 1 ~Generator annunciator display + Selected alarm/shutdown faults + Selected status indications * Identifications of unacknowledged and acknowledged alarms Enercon Quote PG-2101-R3 Page 3 cL 1 — Siemens $7-1200 PLC + 1x Ethernet TCP/IP CPU + 3.x 16 points digital input module + 2x 16 points digital output module + 1x4 points analog input module Analog metering: 1 Synchroscope 1 — Dual frequency meter 1 —Dual voltmeter Miscellanous: I~ 10A charger, 220Vac 1 — Set of 7.2AH batteries 1 =Set of DIN rail mounted auxiliary relays, control wiring, terminal boards, MCB and nameplates Generator Control Panel I - Floorstanding cubicle, top entry control cables access, approximately 2100 mm high x 800 mm wide x 800 mm deep + Powder coated RAL 7035 light grey color + Enclosure: 1P42 + Material: 3.0mm thick steel plate + Finishing: Epoxy poweder coated + Panel light c/w door limit switch + 2x4” Fan @230Vac + Anti condensation heater c/w thermostat control @230Vac + Single socket outlet @230Vac + Service pocket mounted on back of the front door. 1 —Generator Control Module ~ ComAp + Automatic standby. + Automatic synchronizer to monitor the incoming engine generator set voltage, frequency and phase angle with the “live” bus. + Automatic kilowatts load and Var sharing function. + Soft loading and unloading against other generators. 1-12” Siemens HMI + Graphical representation of system status display + Electrical parameters monitoring (alarm & fault status) 1 = Siemens $7-1200 PLC + 1x Ethernet TCP/IP CPU + Lx 16 points digital input module + Lx 16 points digital output module + 2x4 points analog input module + 2xRTD module Enercon Quote PG-2101-R3 Page 4 Controls: 1 — Voltmeter selector switch | 1 —Ammeter selector switch 1 —Engine control switch (Auto-Man-Stop-Oft/Reset) | 1 ~ Synchronizing selector switch (Main-Gen) 1 Circuit breaker control switch (On-Off) 3 — Circuit breaker indicating lights 1 ~ Speed control switch (Lower-Raise) 1 — Voltage control switch (Lower-Raise) 2—Engine start/stop pushbutton 1 — Alarm acknowledge/reset push button 1 — Lamp press to test push button 1 —Genset emergeney stop function Electrical Protections: 1 ~Set Protection shall consist + Reverse power (32) + Reverse reactive power @2RV) + Over/under frequency (810/U) + Under/overvoltage (27/59) + Unbalance current/voltage (60) Digital Metering: 1 —Digital metering display shall include: + Generator AC voltage + Generator frequency + Mains AC voltage + Mains frequency + kW + Power factor + Hour run Analog Metering: 1 —Synchroscope 1 — Dual frequency meter 1 —Dual voltmeter 1 —Syne lamp Miscellanous: 1 = 10A battery charger, 220Vac 1 ~ Set of 7.2AH battery 1 Set of DIN rail mounted auxiliary relays, control wiring, terminal boards, MCB and nameplates Enercon Quote PG-2101-R3 Page § Major Component List Typical Master Control Panel [ Description COO, Model Brand | Mains Control Module — Inteli Mains NTC | Czech IM-NTC-BB ComAp BB & Inteli Vision 5 Republic Inteli Vision S PLC Germany | Siemens + 1.x 87-1200 series CPU | CPU: 6ES7 214-1HG40-0XBO + 3x 16 channels digital input | DI: 6ES7 131-6BH00-0BA0 + 2x 16 channels digital output DO: 6EST 132-6BH00-0BA0 + 1x4 channels analog input Al: 6BS7 134-6HDO0-0BA1 iF HMI Germany GAV2 124-0MCOL-OAXO Siemens ‘Typical Generator Control Panel Description coo Brand Generator Control Module — Inteli Gen Czech IG-NTC-BB ComAp NTC-BB & Inteli Vision 5 Republic Inteli Vision 5 - PLC | Germany Siemens + 1.x $7-1200 series CPU CPU: 6ES7 214-1HG40-0XBO + Lx 16 channels digital input DI: 6ES7 131-6BH00-0BA0 + 1x16 channels digital output DO: 6ES7 132-6BH00-0BA0 + 2x4 channels analog input AL: 6ES7 134-6HD00-0BAI a eee RTD: 6ES7 134-61D00-0CAL i HMI Germany GAV2 124-0MCO1-DAXO Siemens Differential Current Relay Denmark RMC 131D DEIF Enercon Quote PG-2101-RS Page 6 Enercon Asia Private Ltd’s Terms and Condition of Sale CONTRACT OF SALE: Fnewon Asia Private Lu (horns callal~Sollt") agree to sel and bayer ages opus the equine ‘Sscribed inthis Proposal (Confemation] [Inve] pars o these terms and condions, which shall cost th sie cnt se between buyerand seller. These terms apd conditions supersede ad take preesines ver any anal term nla, bt a ted any contrary ters nay documents (aah as purchase odes) suited by bayer seller ‘ORDERS: Orders ae sj to aesptanes at hone oie of Sele PRICES: Unless otherwise specified in writing, all prices ae F018, Sll's plant, and all quotations automaticly expire sisty (0) alent days fom date oF ise unless communicated diftereuy by the Soller. The pice of any equipment sched fo hime on 2 ‘de beyond poriod osx ¢) months fom date of Sols ord confirmation ts subject to merase By Selle, less otherwise aoe to in writing All euipment wil be suitably packet for domestic shipment, no suitable for long tem storage, unless arise agreed wing ‘TERMS: Payment in US. Dollars with normal payment ers ate net cash iy days from date oFinvoiee. Payment sehedule yen! de with purchase oer. 20% payment date completion of appeoved deawings, 35% payietcucon proton reas, 35% Dryient due ypon completion o factory testing. SHIPPING DATE: Seller shall not be responsible for any default or dy in sipping due to contingencies yond ils conto othe onto is suppliers, which prevent or intros with Soller ming delivery onthe dat spocifed,icloding but mt limited wars, or restraints afetng shipping, diver of materials or credit as a result of sis, lockout, Tes, fds, o any other contingency afeting the seller rts supplies, The Sele shall ave the gt cancel a enact of sal oro extend the shipping dt inthe even that ty th ‘omtingencies prevent o delay shipmons. Sell shall not he liable for any losses snuted by ne delivery of equipment. Eps kl by Sater beyond sehaeled delivery date for convenience of buyer wil be foiced on dat of completion, Such equpaent wl subject to charges for warehousing and oe expenses incident such dy DELAYS: Inthe event Buyer causes Seller to delay engineering, manaictrng, shiping, instalation, or sttup of equip wider tis propos any ational oss ieured bythe Selle stall be reimburse by the Bayer Slr shall ot be responsible fr delays in delivery ‘Shused by aes of God, government lig tke, acini, days o deta of Sellers soplier, delays eased by acts of the Buyer of other causes ouside of Salles reasonable contol. Should the Bayer requir the Seller to delay enginering, manufacturing, shipping. installaon or stray by more than tity (30) days, then Seller shall voice the Bayer for 4 ttl of one hun pereent (100%) oF the ‘ale ofall work completed, and sch invoice shal be due and payable nt (15) Been dye, [ENERCON DESIGN: The design information contained herein is propsity ad he sole popes of Enercon Asia Private Ld. The cing and equipment selections inthis proposal ae ased othe interpretation ofthe information supplied to Enercon Asis Private Lid The proposal fs complete as presented herein. Aay changes deviations o addons f the bl f materials as listed wil rue an adjustment to the pice and ay require atonal engincering and may adversely effec the delivery date. Al sotware programs foe PLC or toch Scroon are the Seller's inlet propery. Should the project drawings or progr be anehded by others without Enerom's consent «lsing the warranty period, Enercon will ot be responsible for any mis operations or damage caused By unsubried changes (CHANGES: Should Seer make any changes athe request of the Bayer, oF should changes in sit conditions or installation requiem ‘occur sbsequent to hippos the pts shall r-negvit the pice andthe ie schedules uted herent reflect cost or schedule ‘djusients caused by sad changes. Seller shall not be obligated 0 perform work on amy changes witha writen agrocment fom he Buyer. CONFIDENTIALITY: Buyer sal exp confidential al prices, drawings and tshnical information disclose by the Seller as part of, oF in conjnetion with, this proposal or any resulting contac, incing, Bu ot inet, formation eating the design, instalation, tmateals of constuction, operation rept, maintenance or otherwise ofthe equipment or component pars terol or ote elated items Buyer may disclose said drawings and documents nly to its auhorze employees or contactors wh age othe tes hit parser and who agree not w use said information excep fo the station, operation, apd msinemance of the eqhipment for the Bayer en. Buyer shall tur to Enron Asia Private Lt all drawings and infomation, including that piven to thers by Buyer when contract completed. Buyer shall tun to Fnercon Asia Private Li all drawings and information, neluding that given to thers by Buyer the ob isnotamarded i Enron Asia Private Lid. This paragraph doesnot int Buyers ight use thie information itis obtained from ane source witout estton, INSTALLATION: Enercon Asia Private Lid shall not be responsible for any fell istalaion. I afer commissioning fed service i ‘equied, please use our quot por week ae, Pricing is bated on compte letra and mechanical integration performed by Encteon ‘Asa Private Li (CANCELLATION: Orders ate not subject cancllatons a change spevfctions, shiping schedules or other conditions originally ‘sgieed upon without Seller's written consent and then only upon agement to compensis Seller for expenses incited by such eaeelation ‘orchanges.Canccllaton schedule salle a fllows: 10% Orde revived and entered on alory. work not stare, aerial not ordered 530% Drawings for approval submited, 60%» Approved drawings retired Job releasal for manufacture Ye Material asumlated and production started, 100% Manufacturing competed, ‘TAXES: Any excise tx, sles a, other tne, o duty of any nature arising ou of or assessed against equipment or odes shal be the sole and exclusive esponsibility oF buyer and shall be ded the pices quoted o invoiced and shall nal ereumstanesbe pd bythe Buyer. INSURANCE AND RISK OF LOSS: The cauipment manuietured by Enercon shall tall ies afer deivry to buyer, buyer's agent oF rsprtation company, whichever occu fis Bethe sae responsibil ofthe beer, aa los damage w id expen or ay pat ‘hereof shal be Dome by the buyer (even if Sele hss atanged for ansporaton, nies otherwise agro in wing. Ady equ ak ‘manufactured by Enewon whichis delivered by buyer or buyer's agent to Enercon shal be the sole and exclusive esponsibility of er ‘Buyer must mainain insurance on uny such equipment delivered Seller LIMITED WARRANTY: Equipment manufactured by Enercon is waramted tbe fie rom defect in material and workmanship under omal use, service and indoor sage, fr twelve (12) months afer dae of sarap or eighteen (18) months ar date of shipment Enercon Quote PG-2101-R3 Page 7 ‘Sctk's pln, whichever ose fist, sbjet 1 the following provisions. This waranty is mie 1 spa, eplcement oe Bsuin of ‘ei a Seller ay cls, on Seles manatctoring plat such prs as hall appear Sele. upn inspection, to have bn tive in material or workanai, ba Gos rot iclaeany isallaton, abr oe tansporation cost. All wacanty pars ests will nie a Purchase Onder Aller evalation if dsm be coveted under warranty, the PO will ot be chayged. Ths waranty des pt apply ‘oral maintenance or nova plete a serviceable ems. No warn emg with eypeet 6 kems manatitured by others. Seller Stall ino event beable fr any special or consequential damages. Misapliatn or revisions of equipment, without writen approval by Enercon, will void the insted waranty. Replacement pats shall be warraced fr six (6) months rom date of shipment sje! othe teens and conditions as sae above for aanutactured equipment. Whon the eqnment reaches is final destination, the buyer rout promplly noth caer ot any damage, shold the cise ake, Odherwise, the buyer shal have no ecourve against Enercon. Enero Inspets parts etn for waranty chim formisappicnton. Misuse oF equipment will void hs waranty. Enercon shall in mo event be liable for any speci or consequential charges foe repcing rinsaation of warranty ps. LU_LIMITATION OF REMEDIES AND DAMAGES: ‘The Limited Warranty set forth in Section 13 above iin en of any and all ‘ther express andor implied warranties. All other warrautles, both expres andor implied, iluding but not limited to implied ‘warranties af performance, erchantablty or fines fora particular purpore are expressly disclaimed and denied. Peep forthe Fee set forth in section 13 above, Seller sll not be lable to buyer or any thied party under ths contract. o for anything it ter ofthis contract oF ay los Of business a profits or for any general direct, special, consequential, exemplary, pantve incidental or oer damages, lows or expenses, even if Seller has bees “advised ofthe possibility of such damages, loss or expense. Sele snot responsible Tor any consequence of the use or appleation [OF the products by the buyer, Uhyer shall ndemmity and hold Seller, and is officers, directors employees and agents harmless ‘gins amy and al sss, lain 15 VENUE: Any and al disputes clans or eases of ation aising out oo in any way reaing to any equipment manufictured by Enctoon ‘must be brought inthe Citeit Court fr the Tenth Idiot Cire, Tazewell Cou ins. 16 FUELSURCHARGE: Dee to unexpected tations of fel ree te Wo ever changing worl evens and subsequent matket speculation {el surcharge may be applied ny Engine Load Testing ‘The surcharge wil be adjusted weekly base onthe U.S. National Avene Fel dex of te cument Monday publican min onoad ates. The ue inex, plished bythe Energy information Anniston of the US. Deparuvent of Energy. is avalible by telephone at 2023864966 or ea the department's inkl sit: shone gov oog nivale 17 EXCEPTIONS: Anything nt spcticlly quoted above in ew of ay specication. Enercon Quote PG-2101-R3 Page 8

You might also like