You are on page 1of 2

Bureau Veritas Reference No. Bureau Veritas Certificate No.

IND.M.4.21.0460-TC IND.M.4.21.0460-IRC-0030

INDEPENDENT REVIEW CERTIFICATE


Designer : PARVEEN INDUSTRIES PRIVATE LIMITED
Item Part No. : 12NKGUAXF7 (Parveen)
Item Description : X-OVER: 8.3/8”- 4 ACME OTIS BOX (S.B.5.25”) x 3.1/2”- 9.2# VAM TOP
PIN, ID: 2.972”, SERVICE: H2S, PSL-3.
Work Acceptance date : 22.03.2021
Design Criteria : Internal Work Pressure : 5,000 PSI
External Work Pressure : Not Specified
Test Pressure : 7,500 PSI
Material of Construction : AISI 4130/ 4140, Conforms to L80
as per API-5CT
Temperature Range : 2500 F
Min. Yield Strength : 80000 PSI
Min. Tensile Strength : 95000 PSI
Environment Condition : H2S
Corrosion Allowance : Not Specified
Maximum Tensile Strength : Not Applicable
Reviewed Doc. : Design Specification : DCN-141, Rev. 0
Parveen Group Drawing : 12NKGUAXF7, Rev. 0
Codes and Standards : API 5CT : Specification for CASING & TUBING -
(10th Edition, Addendum 1, 2021) 10th Edition, Addendum 1, 2021
API 6X : Design Calculations for Pressure Containing
(2nd Edition, Feb 2019) Equipment – 2nd Edition, Feb – 2019
NACE MR0175 : Petroleum and natural gas industries —
(3rd Edition, 2015) Materials for use in H2S-containing
environments in oil and gas production

The undersigned, acting within the scope of the BUREAU VERITAS General Conditions of Service which
regulate the intervention of the Society, at the request of Parveen Industries Pvt. Ltd. Mumbai, certify that the
Mechanical Strength Design of the above-referenced item has been appraised based on the documents
submitted by Parveen Industries Pvt. Ltd. Mumbai, and found in compliance with the above Codes and
Standards.
The certificate is issued as per request of Parveen Industries Pvt. Ltd. Mumbai, within the scope of the contract,
documents submitted and does not perpetuate into Compliance to any statutory regulations and / or codes of any
country / region.
Prepared at Mumbai,
On the 22nd December 2022

For BUREAU VERITAS-India

Kasim SHAIKH Kalpesh JORKAR


Manager - Design Appraisal Sr. Design Review Engineer

The technical conclusions thus expressed may have to be re-considered in light of any modifications or alterations that would invalidate the data shown in the
documents that are referred to herein. These conclusions would become null and void should Bureau Veritas not be kept informed of such modifications or
alterations with specific reference to the present certificate.
9.2