Mod.

Boom 10m Samson Replacement of electrical cable


Workshop technical manual

Replacement of electrical
cable

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

1. Bring the boom in horizontal position and make the


extension completely retract.

2. Remove the rear panel.

3. Remove the front guard on the boom hood.

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

4. In case of machine with basket pre-arrangement, remove


the false socket from its seat and position it on the electric
board in place of the socket with cable.

5. In case of machine with basket pre-arrangement,


disconnect the 24 wires inside the socket.

6. In case of machine with electric contact only,


disconnect the 6 wires inside the socket.

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

7. Secure the cable to be replaced to the new cable by


tightening certain wires of the same together; wrap them
with adhesive tape in order to form one uniform cable.

8. Pass to the rear part of the boom.


Remove the clamps holding the cable to the pipes and
start removing the same from the chute inside the boom.

9. Remove the cable to be replaced and the new cable.


Leave the length for the socket connection like in origin, in
the front part of the boom.

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

10. Pull the cable from the lower part of the hose carrier
chain in order to insert the new cable in the same.

11. Once the entire cable has come out from the upper part
of the chain, start-up the engine and lift the boom.

12. Switch-off the engine and secure the safety support to


the lifting cylinder.

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

13. Remove the side guard of the cab and start disconnecting
the cable:

A - Winch basket pre-arrangement.

B - Electric contact pre-arrangement.

14. Connect the new cable to the sockets like in origin following
the reverse phases with sequence “13-4-5/6”.
Respect connection like in origin.

15. Arrange the cable path fastening it with the new


clamps and mount the cab side guard again.

16. Remove the safety support on the lifting cylinder


and lower the boom.

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.
Mod. Boom 10m Samson Replacement of electrical cable
Workshop technical manual

- ATTENTION: - Read the SAFETY REGULATIONS (contained in this manual) carefully for the safety of all personnel and your vehicle.