You are on page 1of 1

Gas Orifice Flow Calculation - Flange Taps

Input Result
Pipe ID, inches 10.021
Orifice ID, inches 3.898 Fb = 3080.700 Basic Orifice Factor
Specific Gravity 0.5216 Fg = 1.384622 Gas Gravity Factor
Flowing temp., F 80.00 Ftf = 0.981296 Flowing Temperature factor
Gauge pressure, psig 175.00 Fr = 1.000151 Reynolds factor
Avg differ., in. H2O 105.000 Y = 1.003300 Expansion factor
Pressure base, psia 14.650 Fpb = 1.005461 Pressure Base factor
Temperature base, F 60.0 Ftb = 1.000000 Temperature Base factor
Atmos. press., psia 14.40 F1 = 0.999950 Assumed 1000' elevation
Reynolds No. Factor 1.000000 Fm = 1.000000 Mercury manometer/dry flow meter
Use this?(0) or Calculate 0.000 1 Fpv = 1.012250 Supercompressibility
Expansion Factor 1.000000 Fa = 1.000222 Orifice thermal expansion factor
Use this?(0) or Calculate? (1) 1
Static Upstream?(0) / Down?(1) 1 Beta = 0.3890 Ratio of orifce diam to line I.D.
Supercompressibility 1.000000 hw/pf = 0.5544 Ratio of differential to absolute
Use this?(0) or Calculate? (1) 1 pressure
Manometer Factor 1.000000

====== === ========= ========== ====== ======== ========= =======


Volume Calculation:

Meter Factor, C'= 4275.6758 Static Range 500


Hourly flow rate= 602,961 cubic feet per hour Diffrl Range 300

You might also like