ISQ UTT Exam Industry Feedback, Gap Assessment & FAQ’s
600 100
500 80
400
60
300
40
200
0 0
Thickness Flaw Total Thickness Flaw Detector
Meter Detector Meter Pass % Pass %
ISQ UTT Exam Industry Feedback, Gap Assessment & FAQ’s
100
80
60
40
6.0 RECOMMENDATIONS
• Low initial pass rates (37%) are indicative • A number of candidates have failed to detect
of lack of training and preparation. Slightly the minimum thickness of wall loss samples.
higher retake pass rates (42%) seem to This suggests that scanning technique and
indicate that some additional training is unit standardization/calibration should be a
being administered prior to retake. ASNT focus of training, including signal analysis,
suggests additional training prior to the equipment setup and adjustment during
examination (see below for specific training scanning (gain, screen range, use of echo to
areas). echo, etc).
• Based on the pass % results for digital • A number of candidates have struggled with
thickness meter vs. flaw detector, it can samples that are coated. This suggests that
be determined that both are acceptable testing of samples with a coating should be a
instruments for taking and passing the exam. focus of training and transducer selection.
17. Where can I find the exam procedure and report form?
ASNT Industry Sector Qualification (ISQ) for Oil & Gas (asntcertification.org)