Professional Documents
Culture Documents
Pile cap =2
Kolom = K1
Diameter = 400 mm
Panjang tiang = 12
Qb = Ab x fb
Qb = Ab x Fb
1 1
Ab = π D 2= = π 400 2= 0,1256 m2
4 4
Fb = μ. Cb. Nc
Dimana μ = factor koreksi, karena p tiang 0,5 <1m maka nilai μ = 0,8
Cb = kohesi tanah dibawah ujung tiang (KN/ m2 )
Nc = Faktor kapasitas Dukung
Metode α (Lempung
Qsi = As x fs
=πxDxp
= 3,14 x 0,4 x 12
= 15,072 m2
Fs = α x cu
= 6 x NSPT 21
= 126 KN/m2
α = factor adhesi (berdasarkan dengan adhesi α mc chellend 1974) pengaruh nilai cu = 0,71
fs = 126 x 0,71
= 89,46
Qsi = 15,072 x 89,46
= 1348,341
Metode
Qs2 = As x fs
As =πxDxP
= 3,14 x 0,4 x
Qs = 1966,6026
Ab = πr 2
0,4
= 3,14 x 2
= 0,19625m2
L tiang = 12 m
LMAT = 2 M
= 52,595 Kn
1
Qa = (Qb + Qs – Wtiang )
SF
1
= 2,5 (71,05242+1966,6026-52,595)
= 794,024 KN
Kuat Dukung Izin
1
Ta = ((0,75 x Qs )+wtiang)
SF
1
= ((0,75 x 1966,6026)
2,5
= 611,0188 KN
Tipe C
CU =