You are on page 1of 1

APPROVAL ISSUE

SIGNATURE:

SEC 2
A 250
KBF FOR ECCC

CONSTRUCTION ISSUE

SIGNATURE:

150
KBF FOR ECCC

CURTAIN TRACK

SEC 1 COPYRIGHT EAST COAST CONSTRUCTION COMPANY


CURTAIN TRACK A 250 PTY. LTD.
REPRODUCTION OF THE WHOLE OR PART OF THE
DOCUMENT CONSTITUTES AND INFRINGES
COPYRIGHT. THE INFORMATION, IDEAS AND
LOUNGE CH-2435 BALCONY CONCEPTS CONTAINED IN THIS DOCUMENT ARE

2431
CH-2538 CONFIDENTIAL. THE RECIPIENT(S) OF THIS DOCUMENT
CH-2538 ARE PROHIBITED FROM DISCLOSING SUCH

250
BULK HEAD

3189
INFORMATION IDEAS AND CONCEPTS TO ANY PERSON
WITHOUT PRIOR WRITTEN CONSENT OF THE
3019 667 600 2874 250 250 2769 COPYRIGHT HOLDER. ECCC HOLDS A LICENSE FROM
ARBT IN RESPECT OF PROPRITARY ITEMS
172
NOTE THIS DRAW ING IS PREPARED BY EAST COAST
CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE
FOR THE USE OF EAST COAST CONSTRUCTION
BED 1

1565
COMPANY PTY LTD AS THE CONTRACTOR ON THIS
PROJECT

UNIT 107 SUB- CONTRACTORS TO CHECK AND VERIFY ALL

600
LEVELS, DATUMS & DIMENSIONS ON SITE AND SHALL
CH-2538 REPORT ANY DISCREPANCIES OR OMISSIONS TO THIS

120
120
OFFICE PRIOR TO START OF WORK & DURING THE

249
AG CONSTRUCTION PHASE.
THE DRAWING ARE TO BE READ IN CONJUNCTION

249
10 AG AG

120
WITH STRUCTURAL, MECHANICAL, ELECTRICAL AND
OR ANY OTHER CONSULTANTS DOCUMENTATION AS
120

120
321
520

CH-2200 152 600 500 600 879

600
TEMPLATE ACCESS
SHAFT

600
AG

3918
700

BED 2

2441

2560

2560
AG CH-2538 M 10.08.2020 MG DAN REVISED AS PER FLOOR PLAN

L 21.01.2020 JN BB RREVISED AS PER COMMENTS


LOUNGE K 06.01.2020 JN BB RREVISED AS PER COMMENTS

3226
AG
CH-2200
187

J 26.11.2019 ASM BB ACCESS PANEL REVISED


770

2803 600 515 G 01.11.2019 ASM BB CURTAIN TRACK REVISED


F 23.10.2019 ASM BB

1665
ACCESS PANEL REVISED
600

3331 E 10.02.2019 ASM BB BATH & ENSUITE CEILING


KITCHEN LINE
AP BELOW
HEIGHT REVISED
600 2731
600

D 09.09.2019 ASM BB PRELIMINARY ISSUE


243 600 2448 C 10.08.2019 ASM BB PRELIMINARY ISSUE
ACCESS PANEL

600
600X600mm B 14.06.2019 ASM BB PRELIMINARY ISSUE
833

600
A 01.05.2019 ASM BB PRELIMINARY ISSUE
BATH 10mm MODULE GAP AP CH-2200 CH-2200
500

786
REV DATE DRN CHK DESCRIPTION
CH-2250

120

249 185
40
CLIENT:
249

206
ASIA PACIFIC

120
863
1040 600 2968 ENSUITE

1009
LAUNDRY

541
CH-2250

CH-2250

541
CEILING CUT-OUT

600
FIX AT SITE
1357

CH-2200 597 600 637


DESIGN & CONSTRUCTION:

1712
600

600
KITCHEN LINE BELOW

623 600 361


216

600
CH-2200 AP

600
571

EAST COAST CONSTRUCTION COMPANY PTY LTD

1713
E-mail: admin@ecccgroup.com.au

160
Telephone: +61 (448)904475

AP/
DETAIL AND DRAFTING:

600
AIR EGGCRATE GRILL
CEILING CUT-OUT
General Notes: FIX AT SITE
343 600 641

151
1. All penetrations for services through metal stud joists and supports shall be fitted LEGENDS:
with snap bushes to protect services from sharp edges.

2. All services shall be securely clamped to avoid displacement and damage through Bradman Technologies Private Limited
transport, movement , water hammer etc and as detailed in the services layout RCP - 9.5mm UNISPAN BORAL BOARD - CH-2538 FROM STRAKEN PANEL (DROP 162mm) 31/22,Victoria Cresent Rd.Egmore,Chennai - 8,India
drawing. TEL: +91 44 42043347 Email: info@bradmanit.com

3. False ceilings linings, framing etc shall be fabricated with non combustable
PROJECT:
materials. - 6mm FC HUME BOARD - CH-2250 FROM STRAKEN PANEL (DROP 450mm) PROPOSED RESIDENTIAL AT PLOT-50&
54,CARL STREET,
4. Fixings for services and fixings for wall studs below fire ceiling layer shall not be WOOLOONGABBA,QLD,AUSTRALIA
located at fire sheet joints. REFERENCE DRAWINGS:
- 9.5mm UNISPAN BORAL BOARD - CH-2250 FROM STRAKEN PANEL (DROP 450mm)
5. All fire ceiling joints shall be taped and set prior to installation of false ceilings and A 250 - SECTIONAL & BLOWN UP DETAILS DRAWING TITLE:
full height walls and sheets laid in a staggered pattern.

6. penetrations through fire ceiling layer for vertical plumbing pipes shall be made
with clean square edges with casing bead left ready for site fixed linings and fire
- 9.5mm UNISPAN BORAL BOARD - BULK HEAD DROP Notes: UNIT 107 - RCP
FOR CURTAIN TRACK - CH - 2435 FROM STRAKEN PANEL (DROP 265mm)

8/10/2020 4:48:30 PM
collars as detailed .
- ALL THE CEILING HEIGHTS ARE MEASURED FROM STRAKEN PANEL DRAWN: CHECKED:
- ALL DROPS ARE MEASURED FROM FIRE CEILING LEVEL
7. Fire linings shall be completed to full perimeter edge of modules. ASM BB
- 10mm PLYWOOD BOARD - CH-2250 FROM STRAKEN PANEL (DROP 450mm) - ALL TOILET CELINGS & LAUNDRY CEILINGS ARE FIXED AT SITE ONLY
8. Check and confirm items 1 to 7 above prior to sheeting false ceilings - DIMENSIONS ARE ALL MEASURED FROM FINISH TO FINISH FIRST ISSUE: SCALE:
- ACCESS PANEL LOCATION IN TOILET TO BE VERIFED BY FACTORY 1802
09/09/19 1 IN 40 @ A3
9. For Lighting layout refer electrical drawing. AG - AIR GRILL PROJECT NO DRAWING NO REVISION

AP - ACCESS PANEL 1802 A 218 M