4A P R O P E R T Y L I N E 1A 2B 1B
STRUCTURAL
EXISTING KUBO EXISTING STRUCTURE
NORTH
3.90
BUILDING LINE
TECHNICAL DESCRIPTION
BUILDING LINE
LOT A = 130.94 SQM
1-2 S58°05'W, 13.27 m
PLUMBING
12.89
2-3 N29°46'W, 10.02 m
13.65
3-4 N58°05'E, 12.89 m
ROOF A ROOF B
7.50
4-1 S31°55'E, 10.00 m SLOPE SLOPE
BUILDING LINE
2-3 S58°04'W, 13.65 m BUILDING LINE
2.25
3A
(130.94 SQM) 2A 3B
(134.64 SQM)
4B
S I D E W A L K
8.13
8.00
10.02 3.90
10.02 ELECTRICAL
20.03
ROAD RIGHT-OF-WAY
1 3D EXTERIOR PERSPECTIVE
A 1 SCALE NTS
3 SITE DEVELOPMENT PLAN
A 1 SCALE 1:100M
01 11
"Intellectual Property Code of the Philippines." June 6, 1997
DATE: PRC REG. DATE: 12/04/2013 DATE ISSUED: 10/25/2022 DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: BACOOR CITY, CAVITE PLACE ISSUED: DATE SIGNED: rehabilitation in the same style as the original of a building to which that copy right relates.
1 2 2' 2" 3 1 2 2' 2" 3 1 2 2' 2" 3
1.00
1.00
ROOF LINE
ROOF LINE
W-3 W-4 W-3
1.40 0.60 1.40
D D-4
0.70 D T&B
D DS
BUILDING LINE
DS
BUILDING LINE
DOUBLE SIZE
T&B CF- 02 CH- 2.50M GUEST ROOM
D-3 FF-02 CF- 01 CH- 2.70M
2.70
2.70
W-3
2.45
2.45
2.50
2.50
0.70 ±0.25 M
1.40 W-3
SINGLE SIZE
1.40
BEDROOM 1
FF-01 D-2 D-2 GUEST ROOM BEDROOM 1
0.80 FF-01
0.80 CF- 01 CH-2.70M
C C C
8.50
TV MASTER T&B
1.20
1.20
6.00
W-4 MASTER T&B CF- 02 CH- 2.50M
LIVING AREA ROOF B
9.50
7.50
7.50
7.50
7.50
7.50
FF-02
0.60 LIVING & D-5 CF- 01 CH- 3.40M
±0.25 M D-3 DS SLOPE
DINING AREA 1.50
3.00
3.00
0.70
ROOF A
3.30
3.30
FF-01 DINING AREA
B' X CLOSET ±0.30 M
B' X CF- 01 CH- 3.40M
B'
D-2 MASTER BEDROOM SLOPE
FULL DOUBLE SIZE 0.80 CF- 01 CH- 2.70M DS
W-2b
3.10
3.10
W-3
MASTER 1.00
BUILDING LINE
B BEDROOM
B B
1.40 D-1 BUILDING LINE
0.90
FF-01
1.00
W-1 W-1 W-2a
1.50
1.50
1.50
1.50
0.60 0.60 1.00
ENTRY PORCH ROOF LINE
0.50
SHELF WINDOW SEAT SHELF FF-03
CH-2.50M
A A A
ROOF LINE
±0.20 M
DS
1.00
W-3
±0.00 M
1.40
ROOF LINE
Y Y
2.70 5.10 2.70 5.10 1.00 2.90 0.80 4.60 1.00
8.00 8.00 10.00
LIGHTING LEGENDS
SYMBOL DESCRIPTION
FLOOR FINISH SCHEDULE CEILING FINISH SCHEDULE CEILING MOUNTED LIGHTING FIXTURE
CODE DESCRIPTION CODE DESCRIPTION
FF-01 600 X 600 HOMOGENOUS POLISHED FLOOR TILES INDOOR PIN LIGHT
CF-01 ½ mm THK. GYPSUM BOARD
FF-02 300 X 600 NON-SKID FLOOR TILES CF-02 ¼ mm THK. FICEM BOARD OUTDOOR PIN LIGHT
FF-03 600 X 600 HOMOGENOUS NON-SKID FLOOR TILES
WALL-MOUNTED ACCENT LIGHT
DAVIES 3007D ECLIPSE DAVIES SUN & RAIN 3004P DAVIES 2400P WHITE SAND NATURAL STONE CLADDING
SUSSEX SHORE
2'' x 8"" CONCRETE SMOOTH CONCRETE WINDOW SILL, 2'' x 8"" CONCRETE WINDOW SILL, SMOOTH CONCRETE 2'' x 8"" CONCRETE
MOULDING, PAINTED SMOOTH CONCRETE FINISH, PAINTED (COLOR: SMOOTH CONCRETE WINDOW SILL, PAINTED SMOOTH CONCRETE SMOOTH CONCRETE PAINTED (COLOR: MOULDING, PAINTED PAINTED (COLOR: FINISH, PAINTED MOULDING, PAINTED
(COLOR: DAVIES SUN & FINISH, PAINTED (COLOR: DAVIES SUN & RAIN FINISH, PAINTED (COLOR: (COLOR: DAVIES SUN & FINISH, PAINTED (COLOR: FINISH, PAINTED (COLOR: DAVIES SUN & RAIN (COLOR: DAVIES SUN & DAVIES SUN & RAIN (COLOR: DAVIES 2400P (COLOR: DAVIES SUN
RAIN 3004P SUSSEX) DAVIES 3007D ECLIPSE) 3004P SUSSEX) DAVIES 3007D ECLIPSE) RAIN 3004P SUSSEX) DAVIES 3007D ECLIPSE) DAVIES 3007D ECLIPSE) 3004P SUSSEX) RAIN 3004P SUSSEX) 3004P SUSSEX) WHITE SAND SHORE) & RAIN 3004P SUSSEX)
1 2 3 SMOOTH CONCRETE
A B C D 3 2 1 D C B A SMOOTH CONCRETE
FINISH, PAINTED (COLOR: SMOOTH CONCRETE FINISH, PAINTED
ROOF APEX 2 SMOOTH CONCRETE
+ 5.00 m SMOOTH CONCRETE DAVIES SUN & RAIN FINISH, PAINTED (COLOR: DAVIES 3007D
FINISH, PAINTED
FINISH, PAINTED 3004P SUSSEX) (COLOR: DAVIES 2400P ECLIPSE)
ROOF APEX 1 & TOP (COLOR: DAVIES 2400P
0.65 0.85
+ 3.50 m
TOP OF ROOF BEAM 1
5.00
F F
3.20
SLIDE SLIDE
F F
NATURAL STONE
GROUND FLOOR CLADDING
F.F.L. + 0.30 m NATURAL STONE EXISTING STRUCTURE EXISTING STRUCTURE EXISTING STRUCTURE EXISTING STRUCTURE
0.30
CLADDING
N.G.L. ± 0.00 m
BACKFILLED LOT
7 FRONT ELEVATION 8 RIGHT SIDE ELEVATION 9 REAR ELEVATION 10 LEFT SIDE ELEVATION
A 2 SCALE 1:100M A 2 SCALE 1:100M A 2 SCALE 1:100M A 2 SCALE 1:100M
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., DATE: PRC REG. DATE: 12/04/2013 DATE ISSUED: 10/25/2022 DATE ISSUED: ----- -----
Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
RIGHT & LEFT SIDE ELEVATION
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS ----- TIN NO.: - - - - - PLACE ISSUED: BACOOR CITY, CAVITE PLACE ISSUED: ----- DATE SIGNED: ----- rehabilitation in the same style as the original of a building to which that copy right relates.
1 2 3 A B C D
ROOF APEX 2
+ 5.00 m
ROOF APEX 1 & TOP ROOF APEX 1 & TOP ROOF APEX 1 & TOP
0.45 0.85
OF ROOF BEAM 2 OF ROOF BEAM 2 OF ROOF BEAM 2
+ 4.15 m + 4.15 m + 4.15 m
0.50 0.65
0.50 0.65
TOP OF ROOF BEAM 1 TOP OF ROOF BEAM 1
+ 3.50 m + 3.70 m + 3.50 m
CEILING LINE 2
+ 3.00 m + 3.00 m
5.00
CEILING LINE 1 CEILING LINE 1
4.15
4.15
3.40
2.70
2.70
SLIDE SLIDE SLIDE SLIDE
0.30
0.30
N.G.L. ± 0.00 m N.G.L. ± 0.00 m N.G.L. ± 0.00 m
BACKFILLED LOT BACKFILLED LOT BACKFILLED LOT
1 2
2.50
+ 2.75 m SHO 4.5mm THK. FICEM BOARD SHO
0.55 0.55 0.45 0.70 0.25
T&B CEILING LINE ON METAL FURRING
(PAINTED FINISH)
C
0.30
MIR
300 X 600 NON-SKID WALL
2.50
TILES (ACCENT)
0.60
1.20
1.20
-25
LAV 300 X 600 NON-SKID WALL
LAV
0.30
TILES
WC
T&B F.F.L. 300 X 600 NON-SKID
-50
FLOOR TILES WC
F.F.L. + 0.25 m
1.70 0.70 0.10
B
A
0.25
VIEW 3 : DINING AREA
2.50
NORTH N.G.L. ± 0.00 m
MASTER T&B BACKFILLED LOT MASTER T&B
13 BLOW-UP PLAN 14 SECTIONAL ELEVATION A & B
A 3 SCALE 1:40M A 3 SCALE 1:40M
2
1.80 + 2.75 m 4.5mm THK. FICEM BOARD
D MIR
300 X 600 NON-SKID WALL
2.50
TILES (ACCENT)
1.30
1.30
-50 TILES
WC
T&B F.F.L. 300 X 600 NON-SKID FLOOR
TILES
0.10
F.F.L. + 0.25 m WC
0.25
A
1.80 B
N.G.L. ± 0.00 m 17 3D INTERIOR PERSPECTIVE
SCALE NTS
NORTH
BACKFILLED LOT A 3
2.10
2.10
2.10
2.10
2.10
SLIDE SLIDE
0.90
0.90
0.90
0.90
FINISHED FLOOR LINE
D-1 D-2 D-3 D-4 D-5
0.90 0.80 0.70 0.70 1.50
TYPE: SINGLE PANEL DOOR TYPE: SINGLE PANEL DOOR TYPE: PVC DOOR WITH LOUVER TYPE: SINGLE PANEL DOOR TYPE: TWO PANEL SLIDING DOOR
MATERIAL: SOLID WOOD MATERIAL: SOLID WOOD MATERIAL: PVC MATERIAL: SOLID WOOD MATERIAL: ALUMINUM WITH 6mm THK.
BRONZE GLASS
JAMB: 2" X 6" DOOR JAMB JAMB: 2" X 6" DOOR JAMB JAMB: 2" X 6" DOOR JAMB JAMB: 2" X 6" DOOR JAMB
JAMB:
FINISH: PAINTED FINISH FINISH: PAINTED FINISH FINISH: PAINTED FINISH FINISH: PAINTED FINISH
SETS REQUIRED: 1 (ONE) SETS REQUIRED: 3 (THREE) SETS REQUIRED: 2 (TWO) SETS REQUIRED: 1 (ONE) FINISH: ANALOK
LOCATION: MAIN ENTRY LOCATION: ALL BEDROOMS LOCATION: ALL T&B LOCATION: BACK (NEAR GUEST ROOM) SETS REQUIRED: 1 (ONE)
LOCATION: LIVING AREA
1.40
0.45
0.45
0.60
0.60
F F
1.20
SLIDE SLIDE
1.70
1.70
0.60
1.80
2.10
2.10
2.10
2.10
2.10
1.20
1.20
F F
1.50
0.60
0.90
0.40
0.40
0.30
TYPE: AWNING WINDOW TYPE: CORNER FIXED WINDOW TYPE: SLIDING WINDOW TYPE: AWNING WINDOW
MATERIAL: ALUMINUM WITH 6mm THK. MATERIAL: ALUMINUM WITH 6mm THK. MATERIAL: ALUMINUM WITH 6mm THK. MATERIAL: ALUMINUM WITH 6mm THK.
BRONZE GLASS BRONZE GLASS BRONZE GLASS BRONZE GLASS
FINISH: ANALOK FINISH: ANALOK FINISH: ANALOK FINISH: ANALOK
SETS REQUIRED: 2 (TWO) SETS REQUIRED: 1 (ONE) SETS REQUIRED: 6 (SIX) SETS REQUIRED: 2 (TWO)
LOCATION: LIVING AREA LOCATION: LIVING AREA LOCATION: ALL BEDROOMS LOCATION: ALL T&B
04 11
"Intellectual Property Code of the Philippines." June 6, 1997
DATE: PRC REG. DATE: 12/04/2013 DATE ISSUED: 10/25/2022 DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: BACOOR CITY, CAVITE PLACE ISSUED: DATE SIGNED: rehabilitation in the same style as the original of a building to which that copy right relates.
TABLE-3
A. GENERAL NOTES: DEVELOPMENT LENGTH FOR STANDARD HOOKS IN TENSION, Ldh
fc' = 21MPa fc' = 28MPa fc' = 35MPa fc' = 42MPa fc' = 56MPa TABLE-6
1. IN THE INTERPRETATION OF THESE DRAWINGS, INDICATED DIMENSIONS SHALL GOVERN AND DISTANCES BAR SIZE (3,000 psi) (4,000 psi) (5,000 psi) (6,000 psi) (8,000 psi)
OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES.
(mm)
(mm) (mm) (mm) (mm) (mm) SCHEDULE OF CONCRETE HOLLOW BLOCK REINFORCEMENT I. NOTES ON COLUMNS
2. THE CONTRACTOR SHALL COORDINATE WITH THE AR, ME, SE, EE, AND OTHER UTILITIES AND EQUIPMENT BLOCK REINFORCEMENT
10Ø 150 150 150 150 150
THICKNESS NOTE 1. LAP SPLICES, WHEN REQUIRED, ARE PERMITTED ONLY WITHIN THE CENTER HALF OF THE COLUMN LENGTH
PLANS FOR THE EXACT SIZE, NUMBER AND LOCATIONS OF ALL SLEEVES OR OPENINGS THRU FLOOR
12Ø 175 150 150 150 150 mm HORIZONTAL VERTICAL AND SHALL BE PROPORTIONED AS TENSION SPLICES. IN NO CASE SHALL THE LAP SPLICE BE LOCATED
SLABS, BEAMS AND WALLS AND ALSO BUILDING DIMENSIONS.
A. MINIMUM LAP SPLICES = 30 DIA. CLOSER THAN A DISTANCE EQUAL TO THE MAXIMUM COLUMN DIMENSION FROM THE FACE OF THE BEAM-
3. ALL REINFORCED CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH THE ACI - 318 - 08 BUILDING
16Ø 350 305 270 250 215 100 10Ø @ 600mm o.c. 10mm at 400mm O.C. B. PROVIDE 1-16O VERTICAL BAR @
CORNERS, INTERSECTIONS, END OF WALLS,
COLUMN JOINT. PROVIDE EXTRA TRANSVERSE REINFORCEMENT OF THE SAME SIZE AND ARRANGEMENT
CODE, AND ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS 20Ø 435 380 340 310 270 AND EACH SIDE OF OPENING.
INDICATED IN THE COLUMN SCHEDULE SPACED AT MOST ONE-FOURTH THE MINIMUM COLUMN SECTION
(LATEST EDITION) IN SO FAR AS THEY DO NOT CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENTS. C. WHERE CHB WALLS ADJOIN COLUMNS
150 12Ø @ 600mm o.c. 12mm at 400mm O.C. RC BEAMS & WALLS DOWELS WITH THE DIMENSION THROUGHOUT THE LENGTH OF THE SPLICE OR 100 mm.
25Ø 545 470 420 385 335 SAME SIZE AS VERTICAL OR HORIZONTAL
REINFORCEMENT SHALL BE PROVIDED.
4. ALL SLABS, BEAMS, GIRDERS AND OTHER STRUCTURAL ELEMENTS WHICH ARE NOT INDICATED, DETAILED, 5. FOR ALL TIED COLUMNS, PROVIDE TRANSVERSE REINFORCEMENT OF THE SAME SIZE AND ARRANGEMENT
28Ø 610 530 475 430 375 D. LINTEL BEAMS SHALL BEAR AT LEAST
DESIGNATED OR INADVERTENTLY OMITTED BUT ARE NECESSARY TO BE COORDINATED WITH ARCHITECTURAL 12Ø @ 600mm o.c. 12mm at 400mm O.C. 16 INCHES (400 mm) ON EACH SIDE OF
200
MASONRY WALL OPENING.
INDICATED IN THE COLUMN SECTION SCHEDULE AND SPACED NO GREATER THAN ONE-QUARTER THE
AND OTHER ALLIED ENGINEERING PLANS AS WELL AS TO COMPLETE THE STRUCTURAL WORKS IN ACCORDANCE 32Ø 695 605 540 495 425
E. PROVIDE POST & LINTEL BEAM @ 3000 O.C. MINIMUM COLUMN SECTION DIMENSION NOR 100mm, OVER A DISTANCE FROM EACH JOINT FACE OF NOT
WITH THE INTENT OF THE PLANS AND SPECIFICATIONS SHALL BE BROUGHT UP DURING PRE-BIDS/MEETINGS/
36Ø 785 680 605 555 480 LESS THAN THE LARGER OF THE MAXIMUM COLUMN SECTION DIMENSION, OR ONE-SIXTH OF THE CLEAR
NEGOTIATIONS. IT IS UNDERSTOOD THAT THE CONTRACTOR HAS PROVIDED AND INCLUDED ALL THESE ITEMS
HEIGHT OF THE COLUMN OR 450mm.
IN THEIR BID. NOTE: λ = 1.0 (NORMAL WEIGHT CONCRETE). 400
400
400
7. THE REQUIRED LENGTH OF LAP FOR COMPRESSION SPLICES SHALL BE AS SHOWN IN TABLE 4.
CYLINDER COMPRESSIVE STRENGTH OF CONCRETE f'C, SHALL BE AS FOLLOWS: 7. UNLESS OTHERWISE DETAILED, TYPICAL BAR DETAILS FOR TIED COLULMNS ARE AS SHOWN IN FIGURE 12.
400
LEGEND:
FOR SIZE AND SPACING
20.7 MPa (3000 psi)
1.1 FOUNDATION TABLE-4 LENGTH OF LAP COMPRESSION SPLICES(mm) OF HOR. & VERT. BARS
SEE SCHEDULE OF CONCRETE
Sj = 100 MM O.C MAX., EXCEPT AS INDICATED IN SCHEDULE.
BAR SIZE f'c = 21.0 MPa f'c = 42.0 MPa HOLLOW BLOCK REINFORCEMENT. So = 100 MM O.C. MAX., EXCEPT AS INDICATED IN SCHEDULE
(mm) (SEE COLUMN SCHEDULE FOR TIES)
1.2 COLUMNS 20.7 MPa (3000 psi)
CHB WALL CONCRETE POST
16 420 520 STEEL RATIO AT ANY Sv = 150 MM O.C., MAX.
PROVIDE 12Ø EXTRA
400
20 540 700 FOR SIZE AND SPACING SECTION WITHIN THIS TIES @ 100 O.C.
OF HOR. & VERT. BARS REGION SHOULD NOT H = FLOOR TO FLOOR HEIGHT OF COLUMN
1.3 FLOOR SLABS, BEAMS & GIRDERS 20.7 MPa (3000 psi) 25 720 1100 CORNER WALL SEE SCHEDULE OF CONCRETE
HOLLOW BLOCK REINFORCEMENT.
EXCEED 8% OF COLUMN
28 810 1200 CLASS B
(a)
.
TENSION SPLICE Lv = PART OF COLUMN BEYOND CONFINEMENT REGION
1.4 SLAB-ON-GRADE 17.25 MPa (2500 psi) 32 900 1300 CHB WALL Lo, Lj = CONFINEMENT REGION
CHB WALL
36 990 1450
.
.
1.5 LEAN CONCRETE
.
10.0 MPa (1500 psi) So
8. A FULL WELDED SPLICES SHALL HAVE BARS BUTTED AND WELDED TO DEVELOP IN TENSION AT LEAST INTERSECTION WALL
NO SPLICE NO WELDS
125 PERCENT OF THE SPECIFIED YIELD STRENGTH fy, OF THE BAR. (SEE FIGURE 1a &1b)) So/2
FOR SIZE AND SPACING
(b)
.
2. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION, RE-HANDLING OF HOR. & VERT. BARS
.
SEE SCHEDULE OF CONCRETE
OR FLOWING. PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEEL BARROWS. 9. CLEAR CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS: HALLOW BLOCK REINFORCEMENT
Sj
.
NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO BUGGIES, So/2
CHB Sw = SPACING INDICATED
WHEEL BARROWS OR BUCKETS, IN WHICH CASE, THEY SHALL NOT EXCEED SIX THOUSAND
1) CONCRETE CAST AGAINST EARTH - 75 mm END WALL DOWEL BARS TO MATCH
ON COLUMN SCHEDULE
(6000mm) IN AGGREGATE LENGTH. So = MAXIMUM COLUMN
2) CONCRETE EXPOSED TO EARTH OR WEATHER-
2-12Ø BARS
(d) CHB HOR. BARS
DIMENSION BUT NOT
3. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS 20 mm TO 36 mm BARS - 50 mm MINIMUM STAGGERED LESS THAN ONE-SIXTH
AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER AND ONLY FOR UNUSUAL CONDITIONS SPACING WHEN WELDED CLEAR HEIGHT OF
- 40 mm 10Ø L TIES @ 200 O.C.
400
16 mm BARS AND SMALLER SPLICES OR MECHANICAL
WHERE VIBRATION IS EXTREMELY DIFFICULT TO ACCOMPLISH. COLUMN OR 450
CONNECTOR ARE USED
3) CONCRETE NOT EXPOSED TO EARTH OR WEATHER- 2-12Ø BARS
C. NOTES ON REINFORCING STEEL BARS SLABS, WALLS, JOINTS - 20 mm NOTE VERY WELL:
LAP SPLICES ALLOWED
BEAMS AND COLUMNS - 40 mm ONLY IN MIDDLE HALF
1. ALL REINFORCING STEEL BARS SHALL BE NEW BILLET, HOT ROLLED, WELDABLE, DEFORMED BARS
(DOWEL) (DOWEL)
CONFORMING TO THE SPECIFICATIONS OF PNS 49: 1986 (ASTM 615) , AND ASTM A706 (GR. 60, WELDABLE)
WHOSE GRADE IS SHOWN ON TABLE 1. R. C. COLUMN OR WALL
D. NOTES ON FOUNDATION
NO SPLICE NO WELDS
t= 90 DEG HOOK
INTERSECTING R.C. COLUMN OR WALL Sh/2
1. THE FOUNDATION IS DESIGNED FOR A FIXED ALLOWABLE BEARING CAPACITY OF 150kPa. 40mm
TABLE-1 TYP. SECTION OF (e) Sj = So So
2. NO FOOTING SHALL REST ON FILL. FOOTINGS FOR CHB WALLS AND OTHER MINOR STRUCTURES SHALL
GRADE BAR DIAMETER (REFER TO ITEM 5)
GRADE 415 (fy = 60 ksi) 16, 20, 25, 28, 32 MM DIA.
BE EMBEDDED AT LEAST 800mm FROM THE NATURAL GRADE LEVEL, LINTEL BEAM ON 50mm
GRADE 276 (fy = 40 ksi) 12 MM DIA. AND SMALLER 3. PROVIDE TEMPORARY REMOVAL OF WATER FROM ANY SOURCE DURING CONSTRUCTION. DEWATERING CHB WALL TYPICAL CONNECTION DETAILS OF So
SHALL BE CAREFULLY AND PROPERLY PERFORMED TO AVOID DISTURBING THE FOUNDATIONS AND
SLAB BEARING SURFACES.
CONCRETE MASONRY UNITS BUNDLED COLUMN REINF.
CONSISTING OF PLANTED
4. CONTRACTOR SHALL DESIGN, INSTALL AND MONITOR EXCAVATIONS RETENTION SYSTEMS, AS REQUIRED FOR AT COLUMN AND/OR WALLS REINF. CUT-OFF BUNDLED COLUMN VERTICAL
BAR REINF. AS SHOWN. REINFORCEMENT
2. THE SUPPLEMENTARY REQUIREMENTS OF WELDABLE DEFORMED REINFORCING BARS SHALL BE AS PROTECTION OF ADJACENT PROPERTIES AND PROVIDE ALL MEASURES AND PRECAUTIONS NECESSARY TO
FOLLOWS: MINIMIZE SETTLEMENT AND PREVENT DAMAGE TO ADJACENT EXISTING OR NEW CONSTRUCTION.
FIGURE 5
2.1 THE MAXIMUM YIELD STRENGTH OF WELDABLE BARS = 540 MPa. 5. PREPARE CONDITIONS OF CONCRETE SUPPLY AND PLACEMENT OF THE TYPICAL TIED COLUMN DETAIL OF REINFORCEMENTS
2.2 THE TENSILE STRENGTH SHALL NOT BE LESS THAN 1.25 TIMES THE ACTUAL YIELD STRENGTH. COMPLETE FOUNDATION FOR THE FULL THICKNESS AS A CONTINUOUS MONOLITHIC CASTING.
3. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED AND SPACED 6. DO NOT BACKFILL AGAINST BASEMENT WALLS UNTIL GROUND FLOOR SLABS HAVE BEEN PLACED AND BAR DETAILS OF TIED COLUMN AT TOP
IN FORMS, SECURED IN THE REQUIRED LOCATION IN ACCORDANCE WITH THE PROCEDURES AND THE CONCRETE HAS ATTAINED THE REQUIRED STRENGTH.
3-12Ø VERT. BARS
REQUIREMENTS OUTLINED IN THE LATEST EDITION OF THE BUILDING CODE AND THE MANUAL OF
STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES, ACI - 315. 7. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL ELEVATOR DETAILS,REFER TO ARCHITECTURAL,
W/ 10Ø TIES AT
150 O.C. (2/SET)
FIG. 12 TYPICAL RECTANGULAR TIED
ALTERNATELY PLACED.
MECHANICAL, PLUMBING AND OTHER TRADES FOR SUBSOIL DRAINAGE SYSTEM, MACHINERY ANCHORS
4. ALL REINFORCING BARS SHALL BE CLEANED THOROUGHLY OF ALL LOOSE RUST, SOIL OR OTHER
MATERIAL IMMEDIATELY PRIOR TO PLACING CONCRETE.
AND OTHER EMBEDDED ITEMS, DEPRESSIONS, FINISHES, DOWELS FOR MASONRY WALLS, CURBS, ETC
COLUMN BAR DETAILS
8. SEE TYPICAL DETAIL OF LIMITING SLOPE OF ADJACENT FOOTING AT DIFFERENT ELEVATION.
5. THE REQUIRED LENGTH OF LAP FOR TENSION SPLICES IS BASED ON THE DEVELOPMENT LENGTH, Ld,
SHOWN IN TABLE 2 FOR RC BEAMS AND GIRDERS, ON THE FOLLOWING CLASSIFICATIONS :
(REFER TO FIGURE 2) 6-12Ø VERT. BARS
W/ 10Ø TIES AT J. NOTES ON BEAMS
(DOWEL)
150 O.C. (2/SET)
1. UNLESS OTHERWISE NOTED IN PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AT LEAST 6mm FOR
TENSION SPLICE SPLICE LENGTH E. NOTES ON SLAB-ON-GRADE TYPICAL DETAIL OF 100 & 150 EVERY 4500mm OF SPAN EXCEPT FOR CANTILEVERS FOR WHICH THE CAMBER SHALL BE AS NOTED IN
CLASSIFICATION
CLASS A 1.0 Ld
CHB CONCRETE POSTS IN THE PLANS OR AS ORDERED BY THE STRUCTURAL ENGINEERS BUT IN NO CASE LESS THAN 19mm
1. THE SOIL SUBGRADE AND FILL LAYERS BELOW ALL SLABS ON GRADE, PAVING AND PIT SLABS SHALL FOR EVERY 3000mm OF FREE SPAN.
BE MECHANICALLY COMPACTED IN LAYERS TO A MINIMUM OF 95 PERCENT OF THE MODIFIED
CLASS B 1.3 Ld
PROCTOR DENSITY,PER ASTM D1557. 2-12ØTOP BARS 1-12Ø FIGURE 6
200
Ø10 STIRRUPS @ 150 O.C.
2. ALL SLABS-ON-GRADE SHALL BE PROVIDED WITH A MINIMUM OF 100mm THK. COMPACTED CLEAN 2. IF THERE ARE TWO OR MORE LAYERS OF LONGITUDINAL REINFORCING BARS IN A BEAM OR GIRDER,
6. TOP BARS ARE HORIZONTAL BARS WITH AT LEAST 300 mm OF CONCRETE CAST BELOW IT.
COARSE SAND BED, EXCEPT AS OTHERWISE DETAILED IN THE PLANS. 2-12Ø BOT. BARS
1-12Ø 2
S-01 USE SEPARATORS OF A SIZE NOT LESS THAN 25mm BARS SPACED ABOUT 900mm ON CENTER. IN NO
3. UNLESS OTHERWISE NOTED, ALL BEDDED SLABS SHALL BE REINFORCED WITH 10mm BARS AT CASE SHALL THERE BE LESS THAN TWO (2) SEPARATORS BETWEEN LAYERS OF BARS.
200mm O.C. EACHWAY AT THE UPPER THIRD PORTION OF THE SLAB.
TABLE-2 2 SECTION 3. LONGITUDINAL REINFORCING BARS SHALL BE PLACED SYMMETRICALLY ABOUT THE VERTICAL CENTER
S-101 LINE OF THE BEAM OR GIRDER SECTION WHERE POSSIBLE WITH UPPER LAYER BARS PLACED DIRECTLY
DEVELOPMENT LENGTH, Ld, IN TENSION FOR R.C. BEAMS, GIRDERS & COLUMNS F. NOTES ON MASONRY WALLS ABOVE THOSE IN THE BOTTOM LAYER.
(PRISMATIC & NON-PRISMATIC) 1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE APPLICABLE
10 O STIRRUPS
fc' = 21 MPa fc' = 42 MPa fc' = 56 MPa STANDARDS AND SPECIFICATIONS OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND at 150 o. c.
(3,000 psi) (6,000 psi) (8,000 psi) 4. MINIMUM CONCRETE PROTECTION OF REINFORCING BARS OR SHAPES SHALL BE AS SHOWN IN FIGURE 13.
BAR SIZE UNIFORM BUILDING CODE.
(mm) TOP BARS OTHERS TOP BARS OTHERS TOP BARS OTHERS TYPICAL DETAIL OF 100 & 150 BEAM REINFORCING BARS BOTH TOP AND BOTTOM, TERMINATING IN A WALL, SHALL EXTEND AT THE
2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 GRADE N, WITH A MINIMUM
(mm) (mm) (mm) (mm) (mm) (mm) LINTEL BEAMS AND TYPICAL DETAILS MOST 50mm FROM THE FAR FACE OF THE WALL AND SHALL TERMINATE IN A STANDARD 90° HOOK.
COMPRESSIVE STRENGTH OF 5 MPa (700 psi).
10Ø 375 300 300 300 300 300 3. MORTAR AND GROUT FOR ALL REINFORCED MASONRY SHALL CONFORM TO ASTM 270-TYPE M AT DOOR OPENING 5. LONGITUDINAL REINFORCEMENT OF GIRDERS, BOTH TOP AND BOTTOM, TERMINATED IN A COLUMN
AND SHALL HAVE A MINIMUM 28-DAYS STANDARD CYLINDER COMPRESSIVE OF 21 MPa CHB WALL CHB WALL
12Ø 450 345 320 300 300 300 SHALL BE EXTENDED TO THE FAR FACE OF THE CONFINED CONCRETE CORE OF THE COLUMN
8. UNLESS OTHERWISE NOTED, EMBEDDED CONDUITS SHALL BE RUN GENERALLY AT MID-BAY AND
PARALLEL CONDUITS SHALL BE AT THREE DIAMETERS ON CENTER. CONDUIT SIZE NOT EXCEED
1/4 OF THE SLAB THICKNESS AND SHALL BE LOCATED AT MID THICKNESS OF THE SLAB.
05
"Intellectual Property Code of the Philippines." June 6, 1997
DATE: PRC REG. DATE: 12/04/2013 DATE ISSUED: 10/25/2022 DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: BACOOR CITY, CAVITE PLACE ISSUED: DATE SIGNED: rehabilitation in the same style as the original of a building to which that copy right relates.
0.30
1 2 2' 2" 3
2.80 3.00 1.05 1.15
FOOTING:
2.80 5.20
STRUCTURAL DIMENSION Thk. Excv. REINFORCEMENT
REMARKS
0.20
1.00
2.65 0.15 1.85 1.00 2.35 DESIGNATION W L T E MAIN BARS
C1F1 1.00 m. 1.00 m. 0.35 m. 1.20 m. 5pcs -16 mm Ø def. bar B.W. isolated footing
C1F1
C1 WF1 C1 WF1 C1 WF1 C1
D 1.50
2.70
WF1
WF1
WF1
1.00 @ 212.50MM O.C.
WF1
COLUMN:
1.20
BOTHWAYS
WF1 WF1
C C1 C1
C1
STRUCTURAL DIMENSION REINFORCEMENTS: ( MAIN BARS = GRADE 60 : MINOR BARS =GRADE 40) PLAN
1.35
WF1
DESIGNATION
WF1
WF1 A B VERTICAL BARS TIES (10 mm Ø def. bar)
3.30
B' 150 MM THK. SLAB ON GRADE C1 200 mm 300 mm 6pcs - 16 mm Ø def. bar 4 @ 0.050 m. & rest @ 0.10 m. O.C.
WF1
1.95
REINFORCED W/ 10 MM Ø C1
WF1
WF1
B C1
C1
1.50
0.85
S 3 SCALE 1:100M
Ø10MM COLUMN
1.20
TIES @ 0.05m O.C.
0.35
1.00
Ø10 BARS SPACED @ 400 MM
VERTICAL REINFORCEMENTS &
Ø10 BARS SPACED @ 600 MM
HORIZONTAL REINFORCEMENTS SECTION
NGL.
30 BAR Ø
30 BAR Ø
(DOWEL)
(DOWEL)
30 BAR Ø
0.50 (min.)
0.20
3-Ø12 BOT. BARS
1.00
FOR DOWNSPOUT
C1 RB1 C1 C1 C1 C1 C1 RB1 C1 RB1 C1
D DS
BUILDING LINE
DS D D
BUILDING LINE
1.00 m
2.70
2.70
RB1 RB1 RB1 EAVES
RB1
C C C1 C1
C1
C C1 C1
C1
8.50
6.00
ROOF B
9.50
7.50
DS SLOPE RB1
3.30
3.30
ROOF A
B' SLOPE
DS
B' RB1
C1
B' RB1
C1 SCALE 1:20M
RB1 S 4
RB1
5cm
BUILDING LINE
B BUILDING LINE
B C1
C1 B C1
RB1 C1 RB1
1.00
1.50
1.50
RB1 RB1 5cm
10cm
0.50
A DS
A C1 C1 RB1 C1 A C1 C1
1.00
15cm
1.00 2.90 0.80 4.60 1.00
25cm
10.00
5cm
ROOF BEAM ROOF BEAM
5 ROOF PLAN 6 FRAMING PLAN 1 7 FRAMING PLAN 2
S 4 SCALE 1:100M S 4 SCALE 1:100M S 4 SCALE 1:100M 15cm
4.70 4.70
13 GUTTER SECTION
S 4 SCALE 1:5M
1.00 3.70 1.00 3.70
7.30 7.30
1.00 5.30 1.00 1.00 5.30 1.00
1.00
1.00
1.00
1.25
BUILDING LINE BUILDING LINE
DS DS
6
1.00
1.00
1.00
1.75
1.25
7
DS DS
BUILDING LINE
BUILDING LINE
1.83
0.55 0.70 0.70 0.70 0.70 0.70 0.70 0.55
1.75
9.50
9.50
9.50
7.50
7.50
7.50
ROOF A 1 1
TRELLIS FRAMING PLAN
DS DS
14
8.00
8.00
8.00
6.00
6.00
6.00
1.83
SLOPE
1.75
ROOF B S 4 SCALE 1:50M
SLOPE 4
4 3
BUILDING LINE
BUILDING LINE
3
1.83
1.75
DS DS
ROOFING WORKS
DS BUILDING LINE DS BUILDING LINE
1 RAFTER: 2'' X 4'' G.I. BAR CHANNEL
1.25
1.25
1.00
1.00
1.00
1.00
1.00
1.00
2 2
2 PURLINS: 2'' X 3'' G.I. TUBULAR METAL
1.00 5.30 1.00 0.80 0.80 0.80 0.70 0.80 0.80 0.80 0.80 3 SIDING: 2'' X 4'' G.I. TUBULAR METAL
1.00 2.90 0.80
4.70 7.30 0.80 0.80 0.50 0.80 0.80 0.80 0.80 4 CONNECTION TYPE: FULL WELD
5 MATERIAL: LONG SPAN ROOFING
CLASSIFICATION: MULTI-RIB TYPE
ROOF A ROOF B
COLOR: BANAWE GREY (pre-painted)
8 ROOF A PLAN 9 ROOF B PLAN 10 FRAMING PLAN 11 FRAMING PLAN DIMENSIONS: 0.50mm X 1060mm X 6.00m
S 4 SCALE 1:100M S 4 SCALE 1:100M S 4 SCALE 1:100M S 4 SCALE 1:100M
6 TRELLIS: 2'' X 3'' G.I. TUBULAR METAL
7 MATERIAL: POLYCARBONATE
07 11
"Intellectual Property Code of the Philippines." June 6, 1997
DATE: PRC REG. DATE: 12/04/2013 DATE ISSUED: 10/25/2022 DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: BACOOR CITY, CAVITE PLACE ISSUED: DATE SIGNED: rehabilitation in the same style as the original of a building to which that copy right relates.
GENERAL NOTES: SCHEDULE OF LOADS
1. ALL ELECTRICAL WORKS INDICATED HEREIN SHALL BE DONE IN ACCORDANCE
WITH THE LATEST ISSUE OF THE PHILIPPINE ELECTRICAL CODE, THE LAWS AND SERVICE ENTRANCE: 230 VOLTS, 60HZ, 2 WIRES + 1 GROUND
ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES, AND THE
TECHNICAL SPECIFICATIONS FOR ELECTRICAL WORKS OF THIS PROJECT.
2. POWER SOURCE SHALL BE 230V, 3Ø, 3W, 60HZ. THERE SHALL BE ONLY ONE
SERVICE DROP TO THE BUILDING.
8. ONLY HIGH POWER FACTOR BALLAST SHALL BE USED FOR FLUORESCENT LAMP
LIGHTING FIXTURE.
15. ALL PANELBOARD SHALL BE PROVIDED WITH GROUNDING TERMINALS. 2-30mm² THHW
1-80mm² THHN/THWN
15 AT 15 AT 2 CATV SINGLE DIAGRAM
CONCRETE POST LIGHTING 1 2 LIGHTING E 1 SCALE N.T.S.
16. TELEPHONE BOX/CABINET SHALL BE PROPERLY GROUNDED. (OPTIONAL) 15 AT 20 AT
LIGHTING 3 4 C.O.
17. CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE AND OF THE MAGNETIC-THERMAL 20 AT 30 AT
TYPE COMMON TRIP WITH THE RATINGS AND NUMBER OF POLES AS INDICATED IN KW - HR METER C.O. 5 6 ACU 1.5HP
THE DRAWINGS. M 100 AT 2P MCB 30 AT 30 AT
1.80 (minimum)
19. THE ELECTRICAL CONTRACTOR SHALL SUBMIT A SAMPLE OF ANY ITEM THAT HE SPARE 11 12 SPARE
INTENDS TO INSTALL OR USE IN THIS PROJECT TO THE ARCHITECT / ENGINEER FOR TELEPHONE OUTLET PULL BOX
150x150x100mm
APPROVAL. 5/8" Ø X 10''
GROUND ROD
1-80mm² THHN/THWN
22. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
1-50mm² THWN
SUPERVISION OF DULY QUALIFIED LICENSED ELECTRICAL ENGINEER.
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., DATE: PRC REG. DATE: DATE ISSUED: DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
PANEL BOARD MANAGEMENT
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: PLACE ISSUED: DATE SIGNED:
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
rehabilitation in the same style as the original of a building to which that copy right relates. CATV & TEL. SINGLE DIAGRAM
1 2 2' 2" 3 1 2 2' 2" 3
D S-q
D ACU WH(SP)
2.70
2.70
f
2.45
2.45
c
2.50
2.50
S-fd
S-ghi S-r
S-p
p r
b
ROOF LINE
C 1.20
h h
k k
C PB-1
CKT-9
TV
TEL
1.20
WH(SP)
k k
7.50
7.50
7.50
7.50
o n PB-1
ACU
i
S-no CKT-8
3.00
3.00
3.30
3.30
PB-1
B' B'
k k
CKT-3 PB-1
j PB-1 CKT-4
ACU
CKT-7
g g k k c
S-lm
3.10
3.10
k k PB-1
ROOF LINE
S-abc S-ejk
B
m
b
PB-1 PB-1 B
1.50
1.50
1.50
1.50
WP
CKT-1 a a CKT-2 WP
ROOF LINE
l PB-1
A a
e A CKT-5
ROOF LINE
SERVICE SERVICE
8.00 ENTRANCE 8.00 ENTRANCE
LEGENDS
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION
WEATHER-PROOF
FLUORESCENT T TELEPHONE OUTLET / WP
CONVENIENCE OUTLET
09 11
"Intellectual Property Code of the Philippines." June 6, 1997
DATE: PRC REG. DATE: DATE ISSUED: DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: PLACE ISSUED: DATE SIGNED: rehabilitation in the same style as the original of a building to which that copy right relates.
GENERAL NOTES:
0.80
0.075
75mmØ PVCP
ACCORDING TO THE REQUIREMENTS OF THE PHILIPPINE PLUMBING 15mmØ ELBOW F.F.L.
0.45
CODE AND THE RULES AND REGULATIONS OF THE GOVERNMENT. PIPE STRAP
0.10
0.50
OUTLET
0.50
0.675
F.F.L. WATER
2. COORDINATES THE DRAWING WITH OTHER RELATED DRAWINGS 0.40 x 0.40 75mmØ PVCP LEVEL 75mmØ PVCP
MANHOLE W/
0.60
0.40
AND SPECIFICATIONS ENGINEER SHALL BE NOTIFIED IMMEDIATELY OUTLET
0.45
15mmØ ELBOW 12Ø LOOSE
0.10
LIFTING HANDLE
OF ANY DISCREPANCY FOUND THEREIN. 75mmØ PVCP
15mmØ CWL PIPE SIZE STEEL PLATE BAR ROD. DIA.
0.10
mm. in. (thick x width) mm. in. 50mm GRAVEL BED
3. PIPES SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT AND 25 1 3.2 x 19 MM 9.5 3/8
4-10mmØ EACH WAY
VARIES
ADJUSTABLE STRAINER
R.C. SLAB STRAINER
PLUG CAST IRON
CAST IRON BODY DRAIN 0.10 0.80 0.10
6. ALL FIXTURE SHALL BE VENTED, UNLESS OTHERWISE INDICATED. BODY DRAIN 32x10mm THK. GALV.
0.05 0.05
FLAT BAR GRATING
@ 25mm OC. 16mm LIFTING HANDLE
7. AIR CHAMBER : ALL INDIVIDUAL BRANCHES TO FIXTURE OR R.C. SLAB
R.C. SLAB
GROUP OF FIXTURE AND / OR EQUIPMENT SHALL BE PROVIDED WITH EARTH FILL
0.15
75mm THK. PRE-CAST
AIR CHAMBER CAPPED VERTICAL PIPE EXTENSION OF DIMENSION CONC.COVER
P-TRAP WITH
AS IN DETAIL. 1/8 (45°) BEND CLEAN-OUT PLUG
0.80
P-TRAP DRAIN PIPE
8. ALL SEWER LINES SHALL BE UPVC PIPE SERIES 1,000,BY EMERALD. CEILING UPPER GROUND FLOOR AND ABOVE LOWER GROUND FLOOR
0.15
P 1 SCALE N.T.S.
10. ALL CIRCUIT VENT SHALL BE UPVC PIPE SERIES 1,000.
BRASS PLUG COUNTERSUNK HEAD
FIN. FLOOR TILES 5 ROOF STRAINER 8 FLOOR DRAIN DETAIL PLAN Ø10 @ 200 O.C.
11. ALL DOWNSPOUT (D.S.) SHALL BE PVC PIPE SERIES 1,000. P 1 SCALE N.T.S.
P 1 SCALE N.T.S.
32x10mm THK. GALV. 16mm LIFTING HANDLE
12. ALL COLD WATER LINES SHALL BE POLYPROPYLENE BY FLAT BAR GRATING @ 0.10
0.05
0.80
0.05
0.10 20mmØ PIPE SLEEVE
VARIES
25mm OC.
75mm THK. PRE-CAST
PHILSATHERM. R.C. SLAB
50x40x8mm THK. GALV. CONC.COVER
5 TOP ANGLE BAR
375x5
GRAVEL BED SHING PVC DOWNSPOUT
13. ALL FCU/AC DRAIN PROVIDE INSULATION E-WHE FOAM OR M E T A L FLA
10mmØ ANCHOR BAR
ARMAFLEX 1/2" THK. RUBBER TYPE. WELDED TO ANGLE BAR
75
1/8 (45°) BEND
0.05
@ 200mm O.C.
0.15
75
14. THE CONTRACTOR SHALL VERIFY ACTUAL TAPPING POINTS AND
300
0.15
16. ALL AFFECTED UTILITIES AND/OR IMPROVEMENTS SHALL BE SCALE N.T.S.
P 1 300SQ
. DRAIN PIPE
RESTORED BY THE CONTRACTOR IN ITS OWN EXPENSE. SECTION
DIMENSION (mm) TOM
PIPE SIZE REMARKS 5 BOT
375x5 LUSHING
A (mm) B C T A L F
SIMILAR TO METMA MODEL ME
50 133 46 M-200-B OR APPROVED EQUAL
75
100
133
175
46
52
- DO -
- DO -
10 CATCH BASIN
LEGENDS 6 TOILET FLOOR DRAIN 9 VENT STACK THRU-ROOF P 1 SCALE N.T.S.
3.45
CWL COLD WATER LINE LAV LAVATORY
0.15 2.00 0.15 1.00 0.15
0.10
0.10
0.60
M WATER METER / SUB-WATER METER HB HOSE BIBB 0.50 0.50 19 MM. Ø
0.30
AIRSPACE
0.15
0.15
INLET
WASTE, SEWER & VENT SYSTEM PLUMBING PIPE FITTINGS 100MMØ PVC
OUTLET
100MMØ PVC
INLET
SEWER PIPE / WASTE PIPE TEE INLET 100MMØ PVC
0.675
0.60
100MMØ PVC
2.00
2.00
1.80
1.50
0.15
1.80
1.50
FCO FLOOR / GROUND CLEANOUT 45° ELBOW LEACHING CHAMBER DIGESTIVE CHAMBER LEACHING CHAMBER
0.675
OUTLET
0.60
CB CATCH BASIN DIGESTIVE CHAMBER 100MMØ PVC
SUPPLY PIPE
STORM DRAINAGE PIPE
0.10
0.10
0.15
0.15
DS DOWNSPOUT 0.15 2.00 0.15 1.00 0.15
3.45
P L A N
11 SEPTIC TANK DETAIL S E C T I O N 12 AIR CHAMBER DETAIL
P 1 SCALE N.T.S.
P 1 SCALE N.T.S.
10 11
"Intellectual Property Code of the Philippines." June 6, 1997
DATE: PRC REG. DATE: 03/05/2014 DATE ISSUED: 01/11/2022 DATE ISSUED: Work of Architecture. - Copyright in a work of architecture shall include the right to control the erection of any building
BLK 4 LOT 41-43, VILLA CRISANTA SUBD., which reproduces the whole or a substantial part of the work either in its original form or in any form recognizably derived
from the original: Provided, That the copyright in any such work shall not include the right to control the reconstruction or
CALOOCAN, BALAYAN, BATANGAS TIN NO.: PLACE ISSUED: BACOOR CITY, CAVITE PLACE ISSUED: DATE SIGNED: rehabilitation in the same style as the original of a building to which that copy right relates.
1 2 2' 2" 3 1 2 2' 2" 3
ROOF LINE
19MMØ PPR PIPE 100MMØ PPR PIPE 50MMØ PPR PIPE
FCO
CB
D D DS CB DS
2.45
2.70
2.70
2.45
2.50
2.50
ROOF LINE
C C FD
WC
FD
LAV
19MMØ PPR FROM WATER MAIN LINE
SHO WC LAV
1.20
1.20
7.50
7.50
7.50
7.50
FCO
100MMØ PPR PIPE VS 50MMØ PPR PIPE
3.00
DS CB
3.00
3.30
3.30
B' B' DS
3''PVC CB DS
EXISTING SEPTIC TANK DS
3''PVC
3.10
3.10
ROOF LINE
B B LC
1.50
DC
1.50
1.50
1.50
ROOF LINE
LC
DS CB
A A
WATER METER
CV DS
ASSEMBLY
GV
8.00 8.00
DS
DS
CB
DS
E
LIN
IPE OF
RP RO
PP E CO
MØ HB PIP F VS
19
M WC PP
R DS
V DS Ø CB
IPE LA M FD
RP 50M C
PP V FD W
Ø LA
MM
IPE
19
E
RP LIN
PP LA
V OF
MØ RO DS E
DS V LIN
9M WC CB LA O OF
1 E DSVC FD FCE RO
O
PP IP
E
SH R
I 3''P WC RP
LIN PP PP
IN Ø FD Ø
MA 0M
M MM
10 S 50 DS
TER V
WA
M CB DSVC
RO LIN
E
RF E DS 3''P OF
PP IP
MØ RP RO
PP
E
LIN
M IPE
25 RP MØ OF
0M
RO
PP
10
E MØ CB DSVC
LIN NK
3''P
0M
IN 10 TA
IC
A
RM PT DS
TE SE LC
WA NG
M
XI STI LC
RO
RF E
PP DC
WATERLINE LAYOUT LY TER Ø
MB E MM
S SE ER M 25
15
M
CV M RO E
W
P R FN LIN
GV
ISOMETRIC DRAWING
P I
P 2 SCALE 1:100M 25 AT
W
Ø MA
MM ER 16
P 2 SCALE 1:100M