Professional Documents
Culture Documents
SlideSmart DC 10F
SlideSmart DCS 10F
SlideSmart DC 15
SlideSmart DCS 15
2 support.hysecurity.com
TABLE OF CONTENTS
(Mode l) (Machine Type) - HS Understanding Gate Status Displays.. 46
Using the Smart DC Controller Buttons in
Table of Contents.................................... 3
RUN Mode............................................ 46
Introducing SlideSmart DC..................... 5
Viewing Operator Status Displays........ 47
Intelligent Features: Smart DC Control-
User Menu............................................. 48
lerTM......................................................................5
Adjusting the Close Timer.................... 48
Technical Support................................... 5
Setting the Time and Date.................... 49
Installer's Check List.................................. 6
Setting AC Power Loss Gate Function.. 49
SlideSmart DC Components..................... 7
Adjusting the Display Contrast............. 51
Safety Requirements.................................. 8
INSTALLER MENU................................. 55
Emergency Stop Button........................ 16
Resetting the OPEN and CLOSE Limits.56
Emergency Release............................... 16
Adjusting Gate Speed.......................... 57
Installation............................................... 17
Adjusting the IES Sensitivity................. 58
Pad Condition....................................... 18
Reinstating Factory Defaults................. 60
Using an Existing Pad........................... 19
Enabling the Fire Department Override.61
Front Installation................................... 20
Smart DC Controller................................ 72
Rear Installation.................................... 21
Overview Of The Smart Dc Controller.. 73
Unpacking the Operator....................... 22
Vehicle Detector Installation Options... 76
Concrete Pad Mount............................. 23
CONNECTING Hy5B VEHICLE DETEC-
Gate Bracket and Chain Installation...... 24
TORS..................................................... 77
Aligning the Chain................................ 25
Installing Standard 11-Pin Box Type Ve-
Connect Battery& Turning DC On........ 26
hicle Detectors...................................... 79
Programming the Initial Setup Menu.... 26
CONNECTING ACCESSORY DEVICES.80
Establishing the Open & Close Limits.. 28
Entrapment Sensor Connections........ 80
Installing the Target Magnet................. 29
Manual Push Button Station.................. 81
Installing the Earth Ground................... 31
User Relays - Programming Procedure. 82
Power....................................................... 31
POWER REQUIREMENTS..................... 85
Wiring AC Power.................................. 32
Bi-Parting Gate Systems.......................... 85
Wiring 115VAC Power.......................... 33
PRIMARY AND SECONDARY WIRING
Wiring 208/230VAC Power................... 34
CONNECTIONS................................... 86
USING A SOLAR POWERED OPERATOR.
Primary and Secondary Menu Setup..... 87
35
ACCESSORY CONNECTIONS................ 88
Design Requirements & Considerations.35
CONNECTING A RADIO RECEIVER FOR
Connecting the SlideSmart DCS to Solar
REMOTE OPEN.................................... 88
Power.................................................... 36
INSTALLING A MAGLOCK OR SOLENOID
Connecting Peripherals to Solar Oper.38
LOCK.................................................... 88
Gate Activity and Solar Zones............... 39
Installing a Lock for 12VDC or 24VDC Sys-
Important Considerations..................... 40
tems...................................................... 89
Installing Extended Battery Backup Kit.41
Installing a Lock for High Voltage Systems
Initial Setup........................................... 43
89
Turning Both Power Switches On......... 43
Installing Vehicle Detectors and Loops.90
Display and Menu Options...................... 43
Monitored External Entrapment Sensors.93
Using the Smart DC Controller Buttons In
EXTERNAL ENTRAPMENT PROTECTION
Menu Mode.......................................... 45
95
Run Mode............................................. 46
Photo Eye Installation Tips.................... 95
NOTICE
Visit support.hysecurity.com for installation manuals, replacement part instructions, part diagrams and more.
4 support.hysecurity.com
INTRODUCING SLIDESMART DC
Thank you for purchasing our premium SlideSmart DC™ slide gate operator. At HySecurity® Gate, Inc.,
we pride ourselves on quality. Our new line of electromechanical gate operators include a number of
unparalleled user benefits:
Robust - An especially low flex, corrosion resistant, steel chassis combines with an attractive, key-locked,
fade resistant, roto-molded cover. The components on the Smart DC Controller™ are protected by
opto-isolators which shield them from power surges and lightning strikes.
Power - The Smart DC Controller provides variable speed control to a powerful, continuous duty
24V DC motor which drives the gearbox. The electronics, motor and gear box are rated to operate in
temperatures that range from -13°F to 158°F (-25°C to 70°C). SlideSmart DC 15 is rated for gates up
to 40 feet long and 1,500 pounds (12m and 682kg). SlideSmart DC 10F is rate for gates up to 40ft and
1,000lbs. (12m and 454kg). Solar options are available for both models.
Finesse - A variable rate of gate acceleration and deceleration, dependent upon gate weight and length,
assures very smooth handling.
UPS backup and Solar ready - Two 12V, 8 amp hour (Ah) batteries will provide a fully functional gate
operator (up to 4000ft/1219m of gate travel) when AC power is unavailable. Four user-selectable UPS
modes are available. 12VDC and 24VDC are available to power accessory controls. An optional base
extension is available that provides space for the optional 50Ah batteries which support solar applications
or usage during extended power outages.
INTELLIGENT FEATURES: SMART DC CONTROLLERTM
Menus and User relays - The Smart DC Controller has over 55 menu items to allow installer configuration
of gate function and two user relays, which can be configured for over 30 different functions.
Independent adjustment for open and close gate speeds - An easy-to-use menu on the Smart DC
Controller allows the installer to vary the open and close speed settings.
Intelligent Inherent Entrapment Sensor (IES) - Any impediment to gate travel is sensed by the system,
stopping gate movement per UL 325 Safety Standards. The intelligent system monitors gate power then
adapts the IES to trip at an adjustable threshold above normal power.
Improved Liquid Crystal Display (LCD) - A 32-character LCD provides increased readability for
programming and troubleshooting.
USB communications port - A direct connect provides accessibility to download system diagnostics
and upload system configurations using the Smart Touch Analyze and Retrieve Tool (START) software.
START software and diagnostics - With START software loaded on a laptop computer, you can get
the latest software upgrade and have an invaluable troubleshooting tool for all HySecurity operators.
To download this free software, visit the HySecurity website at www.hysecurity.com.
TECHNICAL SUPPORT
For technical support, call your installer or authorized HySecurity distributor. Obtain the serial number
of your operator before calling. Refer to SlideSmart Components on the front page. For the name of a
distributor near you, call HySecurity at 800-321-9947.
For information about HySecurity training for installers, maintenance personnel and end users, refer to
the company website at www.hysecurity.com or call 800-321-9947.
Site Prep - concrete pad location/dimensions, distance from gate, chain height, and
mounting considerations: post or base extension, front or rear installation.
Make sure gate installation complies with ASTM F2200 Standard Specification for
Automated Vehicular Gate Construction. And, install the supplied WARNING signs
on both sides of the gate.
Check for compliance with local codes, site conditions, and NEC standards.
Install operator - (on concrete pad use four ½ - 13 x 3.5in long concrete wedge anchors.)
Attach chain end bracket to gate at proper height.
Attach chain to end brackets and feed under SlideSmart idlers and over chain sprocket.
Tighten chain using tensioning bolts.
Verify chain is level with idlers and parallel to operator and gate.
Connect red wire to DC Power Switch.
Turn DC Power ON.
Complete Initial Setup Menu programming.
Install the target magnet and make sure it is in line with and passes by the target sensor
so it can be recognized by the software programming.
Connect AC Power.
Connect all accessory devices.
Set the Close Timer (through the User Menu).
Set gate speed, if applicable (through Installer Menu). Refer to START ("Smart Touch
Analyze and Retrieve Tool" on page 114 in the "Reference" on page 88.
Adjust IES sensitivity, if needed (through Installer Menu).
Check the Smart DC Controller software version. If needed, upload the latest version
from www.hysecurity.com. See "Smart Touch Analyze and Retrieve Tool" on page 114.
Program changes through the Installer Menu depending on the accessory devices
that you have installed.
Give a copy of the operator instructions to the end user. Show the end user how to:
• Remove the operator cover. Turn the power off and on to demonstrate learn
limits after DC/AC cycles.
• Turn the DC power switch off, which disengages the motor, and manually push
the gate.
• Test the red Emergency Stop Button located on the side of the control box. It
can be accessed through a hole in the cover. See illustration on page XXX.
Take photographs of the completed installation site and save it in your business files.
Install external entrapment sensors as needed.
Refer to "Parts & Limited Warranty" on page 133 for SlideSmart parts list.
6 support.hysecurity.com
SLIDESMART DC COMPONENTS
COVER, LATCH
COVER
WARNING
LABEL
BOARD, SMART
CONTROL BOX DC CONTROLLER
PROTECTION
PLATE
& COVER BUZZER O
DC
POW
OF
GEARBOX
CIRCUIT
BRUSH BREAKER
KIT 115VAC O
AC
SERVICE POW
Service OF
Out
115VAC, let
OUTLET 15A
TRANSFORMER
SPROCKET
SERIAL # LOCATION
TARGET SENSOR (x2)
IDLER (x2)
BASE
PLATE
30 ft OF #40 CHAIN,
BRACKET & HARDWARE
Entrapment Zone
8 support.hysecurity.com
SAFETY REQUIREMENTS
WARNING
To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING
GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object
activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to
adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the user’s manual. Have a qualified service person make repairs to
gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS.
Class I: Intended for use in a location of one to four single family dwellings
Class I
or a parking area associated with one to four single family dwellings.
Class II: Intended for use in a commercial location or building such as a multi-
Class II family housing units (five or more single family units) hotels, garages, retail
stores or other buildings servicing general public.
Class III: Intended for use in an industrial location or building such as factories
Class III
or loading docks or other locations not accessible by the general public.
Class IV: Intended for use in guarded industrial locations or buildings such as
an airport security area or other restricted access location, not servicing general
Class IV public, in which access is monitored by security personnel or via closed circuitry.
Install this gate operator only when: For gate operators utilizing a non-contact sensor (Photo
Eye):
● The operator is appropriate for the construction of the
gate and the Usage Class of the site. ● See instructions on the placement of non-contact
sensors for each type of application.
● All openings of a horizontal slide gate are guarded or
screened from the bottom of the gate to a minimum of ● Care shall be exercised to reduce the risk of nuisance
1.83 m (6 ft) above the ground to prevent a 57.2 mm (2-1/4 tripping, such as when a vehicle trips the sensor while
in) diameter sphere from passing through the openings the gate is still moving.
anywhere in the gate, and in that portion of the adjacent ● One or more non-contact sensors shall be located where
fence that the gate covers in the open position. the risk of entrapment or obstruction exists, such as the
● All exposed pinch points are eliminated or guarded. perimeter reachable by a moving gate or barrier.
● Guarding is supplied for exposed rollers. For a gate operator utilizing a contact sensor (Edge):
The operator is intended for installation only on gates used for ● One or more contact sensors shall be located where
vehicles. Pedestrians must be supplied with a separate access the risk of entrapment or obstruction exists, such as at
opening. The pedestrian access opening shall be designed to the leading edge, trailing edge, and postmounted both
promote pedestrian usage. Locate the gate such that persons inside and outside of a vehicular horizontal slide gate.
will not come in contact with the vehicular gate during the entire ● A hardwired contact sensor shall be located and its
path of travel of the vehicular gate. wiring arranged so that the communication between
the sensor and the gate operator is not subjected to
The gate must be installed in a location so that enough mechanical damage.
clearance is supplied between the gate and adjacent structures
when opening and closing to reduce the risk of entrapment. ● A wireless device that transmits radio frequency (RF)
Swinging gates shall not open into public access areas. signals to the gate operator for entrapment protection
functions shall be located where the transmission of
The gate must be properly installed and work freely in both the signals are not obstructed or impeded by building
directions prior to the installation of the gate operator. Do structures, natural landscaping or similar obstruction. A
not over-tighten the operator clutch or pressure relief valve wireless device shall function under the intended end-
to compensate for an improperly installed, improperly use conditions.
functioning, or damaged gate. ● One or more contact sensors shall be located on
the inside and outside leading edge of a swing gate.
Permanently mounted controls intended for user activation Additionally, if the bottom edge of a swing gate is greater
must be located at least 1.83 m (6 ft) away from any moving than 152 mm (6 in) but less than 406 mm (16 in) above
part of the gate and where the user is prevented from the ground at any point in its arc of travel, one or more
reaching over, under, around or through the gate to operate contact sensors shall be located on the bottom edge.
the controls.
USE OF VEHICLE DETECTORS
● Exception: Emergency access controls only accessible Use of vehicle detectors (loop detectors) is strongly
by authorized personnel (e.g. fire, police, EMS) may be encouraged to prevent damage to vehicles caused by
placed at any location in the line-of-sight of the gate. gates closing on them. This is not considered to be a safety
The Stop and/or Reset button must be located in the line- item as most vehicle detectors cannot provide protection
of-sight of the gate. Activation of the reset control shall not to pedestrians. In some situations, photoelectric devices
cause the operator to start. may be used as vehicle detectors, but should be wired
accordingly.
A minimum of two (2) WARNING SIGNS shall be installed,
GATE CONSTRUCTION AND SAFETY
in the area of the gate. Each placard is to be visible by
Gate construction plays a very important role in ensuring
persons located on the side of the gate on which the placard
the safety of any automated gate system. The standard for
is installed.
gate construction is ASTM F2200. Below are key areas to
address in gate design for safety. For complete information
consult the standard. Copies of the standard are available
at: https://www.astm.org/Standards/F2200.htm.
10 support.hysecurity.com
SAFETY REQUIREMENTS
Another source of information is available from DASMA, the The following provisions shall apply to Class I, Class II,
Door and Access System Manufacturer’s Association. The Class III, and Class IV vehicular horizontal slide gates:
Association publishes Technical Data Sheets, one of which All weight bearing exposed rollers 8 ft (2.44 m), or less, above
concerns ASTM F2200. For more information, see: grade shall be guarded or covered.
http://www.dasma.com/PDF/Publications All openings shall be designed, guarded, or screened from
the bottom of the gate to the top of the gate or a minimum of
General Requirements for gate construction: 72 inch (1.83 m) above grade, whichever is less, to prevent
● Gates shall be constructed in accordance with the a 2-1/4 inch (57 mm) diameter sphere from passing through
provisions given for the appropriate gate type listed. the openings anywhere in the gate, and in that portion of
Refer to ASTM F2200 for additional gate types. the adjacent fence that the gate covers in the open position.
The gate panel shall include the entire section of the moving
● Gates shall be designed, constructed and installed to not fall gate, including any back frame or counterbalance portion of
over more than 45 degrees from the vertical plane, when a the gate.
gate is detached from the supporting hardware. A gap, measured in the horizontal plane parallel to the
roadway, between a fixed stationary object nearest the
● Gates shall have smooth bottom edges, with vertical bottom roadway (such as a gate support post) and the gate frame
edged protrusions not exceeding 0.50 in (12.7 mm) other when the gate is in either the fully open position or the fully
than the Exceptions listed ASTM F2200. closed position, shall not exceed 2-1/4 inches (57 mm).
● The minimum height for barbed wire shall not be less than 6 Exception: All other fixed stationary objects greater than 16
ft (1.83 m) above grade. The minimum height for barbed tape inches (406 mm) from the gate frame shall not be required
shall not be less than 8 ft (2.44 m) above grade. to comply with this section.
Positive stops are provided to limit travel to the designed
● An existing gate latch shall be disabled when a manually
fully open and fully closed positions. These stops shall be
operated gate is retrofitted with a powered gate operator.
installed at either the top of the gate, or at the bottom of the
● A gate latch shall not be installed on an automatically gate where such stops shall horizontally or vertically project
operated gate. no more than is required to perform their intended function.
All gates shall be designed with sufficient lateral stability to
● Protrusions shall not be permitted on any gate. Consult assure that the gate will enter a receiver guide. Consult ASTM
ASTM F2200 for exceptions. F2200 for details on various gate panel types.
● Gates shall be designed, constructed and installed such
that their movement shall not be initiated by gravity when EXTERNAL ENTRAPMENT PROTECTION
an automatic operator is disconnected.
SENSORS
● For pedestrian access in the vicinity of an automated Most HySecurity gate operators are equipped with a Type A,
vehicular gate, a separate pedestrian gate shall be Inherent Entrapment Sensor (IES). UL 325 Safety Standard
provided. The pedestrian gate shall be installed in a compliance requires installation of external entrapment
location such that a pedestrian shall not come in contact protection sensors, the number of which, depends on
with a moving vehicular access gate. A pedestrian gate entrapment hazards that exist at each particular installation.
shall not be incorporated into an automated vehicular
gate panel. To comply with UL 325, the following external sensors may
be used:
● Any non-automated gate that is to be automated shall be
upgraded to conform to the provisions of this specification. ● Contact sensors, such as edge sensors
● Non-contact sensors, such as photo eyes
● This specification shall not apply to gates generally
Site designer or installer can choose either photo eyes, edge
used for pedestrian access and to vehicular gates not
to be automated. sensors, or a combination of these devices.
UL 325 Safety Standard for automatic sliding gates
● Any existing automated gate, when the operator requires
specifically requires that edge sensors, photo eyes, or a
replacement, shall be upgraded to conform to the
combination of both devices be installed to protect against
provisions of this specification in effect at that time.
pedestrian entrapment in BOTH directions of gate travel and
wherever entrapment hazards exist.
325
installation to determine list for ULgreatest
where compliantentrapment
recommendations
risks exist. Locate edge sensors
gate automation solutions. Contact the sensor manufacturer for specific
for use.
and/or photo
accordingly. Be certain that a sufficient number of sensors
sensors
"AS1502-*
Edge Sentir Series ASO Safety AS1501-*" • • • • •
Sensors
CPT210-2U-#-T2 Miller Edge - • • • • •
Recommended External Entrapment
Hy2NC (Converts 10K
Edge Sensor to NC Monitoring) HySecurity MX4018 • •
Converters
Protection Sensors List
GEM103 (Converts 10K
to Pulsed Monitoring) Miller Edge - •
Edge Transmitter
Wireless iGAZE RE KitThe following sensors
Solutions have
- been tested with Nice | HySecurity
• • gate operators
• by an
• •
Kits independent laboratory and certified to comply with UL 325 7th Edition. Select sensors from •this
325
WEL-200 EMX - • • • •
list for UL compliant gate automation solutions. Contact the sensor manufacturer for specific
Multi-Input
recommendations for use.
Module The Solution – MIM-62 Miller Edge - • • • •
UL 325 Standard:
Nice | HySecurity Recommended Sensors Control Boards
• The operator shall monitor for the presence of every device at least once during each open and close cycle (32.1.8)
• It shall not be possible to make
Mfg. Part # orsimple modifications in the field by adding,
Nice | suppressing
Max Smartor changing,
Smart either on the operatorMercury
or external
entrapment protectionModel Brand
device(s), to bypass, Hysecurity
interfere with, or otherwise Range
defeat theTouch
monitoringDC SmartCNX
function. (32.1.10) 1050 310
• Entrapment zones are now defined for each gate type (4.23, 4.24,
Part # 4.29, 4.34)
E3K-R10K4-NR-1 Omron MX000999 40 ft • • •
Slide Gates: To enable fully automatic operation, all SLIDE gate operators will require a minimum of TWO monitored external
Photo Eyesprotection
entrapment sensors (one for EMX
NIR-50-325 each direction) to- protect entrapment
45zones
ft in •both the open
• and close
• direction
• of travel.•
(Retro
Preferred solution for slide gates: A photo eye for the close direction and a hard-wired edge sensor for the open direction that
-reflective)
is mounted to IRB-RET
the face of the leading EMX
post of the fence -behind the gate. (Reach
53 ft •
through •
injuries •
are the most •
common hazard •
associated with automatic sliding gates)
E-931-S50RRGQ Seco-Larm - 46 ft • • • •
Swing Gates: To enable fully automatic operation, all SWING
EPMB/A gate operators will require a minimum of ONE monitored external
entrapment protection sensor to protect entrapment zones in either the open or close direction of travel. However, an additional
EPMOB/A
monitored sensor is required if there is a risk of entrapment in both directions of gate travel.
EPLOB/A
Blue Bus Nice | EPMAB/A
Preferred
Photo Eyessolution for swing gates: A photo
Era Photo Eyes
eye for the EMBORB/A
HySecurity
close direction and/or
45 ft
a hard-wired wraparound edge
•
sensor on
•
the leading
•
edge of the gate, which protects for both directions of gate travel.
(Thru-Beam)
OVS-50TNR Optex - 33 ft • •
hysecurity.com | 800-321-9947 Page 1 of 2
IRB-MON EMX MX3990 65 ft • • • •
E-960-D90GQ Seco-Larm - 90 ft • • • •
12 support.hysecurity.com
"AS1502-*
Protection Sensors List
The following sensors have been tested with Nice | HySecurity gate operators by an
independent laboratory and certified to comply with UL 325 7th Edition. Select sensors from this
SAFETY REQUIREMENTS
325 list for UL compliant gate automation solutions. Contact the sensor manufacturer for specific
recommendations for use.
"AS1502-*
Edge Sentir Series ASO Safety AS1501-*" • • • • •
Sensors
CPT210-2U-#-T2 Miller Edge - • • • • •
Edge Transmitter
Wireless iGAZE RE Kit Solutions - • • • • •
Kits WEL-200 EMX - • • • • •
Multi-Input
Module The Solution – MIM-62 Miller Edge - • • • •
UL 325 Standard:
Installers must assess each specific site and
• The operator shall monitor for the presence of every device at least once during each open and close cycle (32.1.8)
install
• It shall not be possible sensors
to make that
simple modifi protect
cations in the fieldall potential
by adding, entrapment
suppressing zones.
or changing, either on the operator or external
entrapment protection
For device(s),
more to bypass, interfere
information visitwith, or otherwise
Safety or seedefeat the monitoring
latest operator function.
manuals (32.1.10)
at
• Entrapment zones are now defined for each gate type (4.23, 4.24, 4.29, 4.34)
support.hysecurity.com
Slide Gates: To enable fully automatic operation, all SLIDE gate operators will require a minimum of TWO monitored external
entrapment protection sensors (one for each direction) to protect entrapment zones in both the open and close direction of travel.
Preferred solution for slide gates: A photo eye for the close direction and a hard-wired edge sensor for the open direction that
Slide
is mountedGate
to the face of the leading post of the fence behind the gate. (Reach through injuries are the most common hazard
associated with automatic sliding gates)
Common
Swing Gates: To enable fully automatic operation, all SWING gate operators will require a minimum of ONE monitoredPUBLIC external
Install Edge for an additional
Entrapment
entrapment protection sensor to protect entrapment zones in either the open or close direction of travel.
monitored sensor is required if there is a risk of entrapment in both directions of gate travel.Draw-in Zone
However,
Zones
1 wraparound
Preferred solution for swing gates: A photo eye for the close direction and/or a hard-wiredProtects open direction
edge sensor on the leading
A Trailing
edge of the gate, which protects End of gate travel.
for both directions (EDGE OPEN)
hysecurity.com | 800-321-9947
eye1 of 2
Install PhotoPage
2 Protects Leading End
(EYE CLOSE)
Leading End
A Indicates Additional Potential Entrapment Zone
SECURE
14 support.hysecurity.com
SAFETY REQUIREMENTS
Recyclers and manufacturers alike promote the process MAINTENANCE OF GATE SYSTEMS
of recycling metal and plastic. Using a metal and plastic To keep your automated gate system performing both safely
recycling center promotes energy cost savings. and reliably it is important to ensure that the components of
that system are functioning properly.
WIND LOAD FACTORS & SITE PREP At least monthly:
Wind load is always a factor when
considering the appropriate gate for a ● Disconnect the gate operator and manually move the
particular site. Solid gate panels produce gate through its range of travel. Note any squeaks from
a larger wind load than gates with slats rollers or hinges or areas of binding. The gate should
or open decorative features. If you are travel smoothly and quietly throughout its range. If it
installing a gate operator in a high wind does not, contact a gate professional to correct the
area, gate design will affect the load on problem.
the gate operator because wind load acts ● Reconnect the gate operator and perform the following
the same as an obstruction. Good gate tests:
panel design presents a low surface area • With the gate opening, block any photo eyes and/
to reduce the wind load. or depress any safety edges used to protect the
open direction. The gate should stop and/or reverse.
If gate is heavy and near weight capacity of what the gate
operator can handle (see specifications), make sure it has • With the gate closing, block any photo eyes and/or
an open design that allows wind to flow through it. A solid or depress any safety edges used to protect the close
semi-solid gate design under certain wind load conditions direction. The gate should stop and/or reverse.
may cause damage to gate operator and is not covered by • Using a suitable obstruction in the path of the gate
the HySecurity Limited Warranty. (a solid, immovable object), run the gate in the open
direction until it contacts the obstruction. The gate
Several factors play into calculations of wind load on a gate should stop and reverse.
panel. To find out maximum wind speed in areas around
• Using a suitable obstruction in the path of the gate
the United States, search for US government wind speed (a solid, immovable object), run the gate in the close
maps on the internet. If you don’t know how to calculate for direction until it contacts the obstruction. The gate
wind load, ask a mechanical engineer or site architect for should stop and reverse.
assistance prior to installing gate operator and gate panels.
When the IES trips, it sends a signal to gate operator to stop
and reverse direction. This feature may be falsely triggered
in excessively windy conditions because wind itself, acting
over surface area of gate panel, can provide necessary
force to trigger IES.
CAUTION
Do not adjust IES sensitivity to accommodate for
inappropriately designed gate panels. Loss of IES
sensitivity increases mechanical wear on gate
hardware and gate operator. It may also pose a safety
hazard. Compensating for wind loads by adjusting
IES may set IES sensitivity to a level which, when
encountering an obstruction, ignores obstruction and
fails to reverse direction. For more information, refer to
Adjusting the IES Sensitivity.
NOTICE
If you turn OFF both power switches (AC and
DC), the operator will search for the target
to re-establish its limits. When you turn AC &
DC power back ON, the operator will cycle
the gate and search for the target magnet (its
“home” position). An operator with the DC
Red Emergecy power switch ON and the AC power switch
Stop Button OFF still functions normally, but “NO AC”
flashes in the display. If you “push” the gate,
it will push back as the position sensor is active
and the motor is engaged.
Figure 1. Red Emergency Stop Button
16 support.hysecurity.com
INSTALLATION
Site Overview & Planning
Key or Card reader
Mount access control Pedestrian gate.
devices at least 6� Make sure a separate walk-
(183cm) beyond the gate. through entrance is available
and its pedestrian path is
clearly designated.
Public Side
Photo eye
Maximum 2¼" (57mm)
width between Edge sensor on Physical
ver�cal bars leading edge stop
V track
Edge sensor
on trailing
edge To comply with ASTM F2200, a screened wire
ate mesh extends to the top of the gate or to a mimimum
Ha nd G
Le� ing height of 6 �. (183cm) if a 2¼" (57mm) or larger gap exists
n
ope SlideSmart
between the ver�cal bars.
Earth ground Secure Side
Target magnet on chain
SlideSmart
operator
Conduit runs
2" (5cm) above
concrete pad
20.7"
Chain Minimum pad (52.6cm)
Ground height is 2" (5cm)
3 max. lug above grade level.
Ground (91.4cm)
wire & rod
Grade level
Vehicle loop
control wires
Extra conduit
(Dual Gate wiring)
Consult local (Conduit may be shared with low voltage wires)
codes for Low
proper depth voltage/Communicaon wires
Concrete pad
(depth set per Cut-away
local codes) view
6.4" Chain, Gate
(16.3cm) #40 Roller
High voltage wires
Main AC power
Grounding rod depth at Area
10 (3m) or per local code 10.5" cut out
(26.7cm) for
conduit 21"
6.9 x 12" (53.3cm)
(17.5 x 30.5cm)
1.6"
(4.1cm)
18 support.hysecurity.com
INSTALLATION
USING AN EXISTING PAD To use an existing pad, take the following steps:
In many applications, SlideSmart may be a 1. Remove any existing equipment from the pad.
replacement operator for an existing gate system. 2. Measure the pad to ensure it is sized properly
Make sure the pad is level and inspect the pad for: for SlideSmart.
• Compliance with local building codes. 3. Check the mounting hole locations and re-drill,
if necessary.
• Appropriate distance from the gate. See Figure
3. 4. Follow the steps in "Concrete Pad Mount" on
• Appropriate dimensions (See Figure 3) for page 23.
SlideSmart installation. CAUTION
• Durability.
Consider positioning the operator so existing
conduit enters the cutout in the SlideSmart
base plate. Cutting small holes in the plastic
base plate and cover for pre-existing conduit
is permissible. Two 0.875-inch (22mm) diameter
holes for running conduit are also provided on
both sides of the chassis. See Figure 4.
Gate
Chain to Gate
Ideal distance = 3-1/4" (8.25cm)
Min. distance = 2-1/2" (6.4cm)
Cut out
if rear
Chain
install
height
7¾"
(19.7cm) Grade
level
Conduit cut outs
Concrete pad
Figure 5. Conduit Cut Out Views
Side View
Figure 4. Conduit Side View
Public Side
CHAIN
OPTIONAL
50Ah
batteries
20 support.hysecurity.com
INSTALLATION
REAR INSTALLATION
A rear installation requires additional idler wheels and gate brackets, but it provides aesthetics as the
chain is not visible along the gate. See Figure 7.
CHAIN SPROCKET
OPEN
Target magnet posi�on
between idler wheel and
sprocket when gate is
IDLER WHEEL fully closed.
OPEN
TARGET
SENSOR
te
d Ga
e� Han
L
ning
ope Idler Post
Posi�on post to maintain a minimum
distance of 1 foot (31 cm) from the end
of the gate when gate is fully closed. Gate
Chain to Gate
Ideal distance = 3¾" (9.5cm)
Min. distance = 2½" (6.4cm)
Lengthen the
chain access slot by
5" cu�ng the cover on
the chain side only.
8"
8" (20.3 cm)
Chain 17½"
height (44.5cm)
7¾"
(19.7 cm)
Side View
LATCH
COVER
Service Ou
tle
115VAC, t
15A
BASE PLATE
22 support.hysecurity.com
INSTALLATION
CONCRETE PAD MOUNT
Install the operator, by taking the following steps:
1. Place the operator on the pad to best suit the
conduit as shown in Figure 2. Use the operator
as a template and center it on the pad. The
chain path must be parallel with the gate. ½ - 13 x 3½"
Concrete
concrete
2. Assess any limitations in the chain path such pad
anchors (x4)
as gate support posts. Adjust the operator’s
location as required. Mark the mounting
locations based on gate, operator, and chain
Grade Concrete
requirements. Mark the drill point at the center level base
of the slot to allow for adjustments. See Figure
3 and Figure 10.
3. Remove the operator from the concrete pad
and drill the holes for the concrete anchors.
See Tip. Figure 10. Concrete Anchors
4. Mount the operator with four ½ - 13 x 3½-inch TIP: To keep pinpoint accuracy while drilling the
concrete anchors as shown in Figure 9. mounting holes in the concrete, use a 3/16-inch
bit to pilot the holes and then move to a ½-inch
5. For additional types of mounting options, refer drill bit.
to the Appendix.
6.4" Chain,
(16.3cm) #40 Roller Chain resides inside
gate support posts
parallel with the gate.
10.5" SlideSmart
(26.7cm) Conduit Operator
Cut Out Gate
21"
(53.3cm) Suppot
Posts
SECURE
Public Side
Secure Side
Trailing edge
view
Chain bracket
24 support.hysecurity.com
INSTALLATION
ALIGNING THE CHAIN
1. For a front installation, feed the chain over the
sprocket and beneath the idler wheels. See
Figure 12.
CORRECT INSTALLATION
2. For a rear installation, see Figure 7.
3. In either situation, make sure the chain is
properly aligned horizontal to the ground and
Chain to gate
parallel to the gate. See Figure 13 – Figure 15.
Ideal distance =3¾"
(9.5 cm)
TOP VIEW
INCORRECT INSTALLATION
Figure 13. Rear View Chain Installation
Figure 15. Incorrect Rear View Chain Installation
SIDE VIEW
INCORRECT
CORRECT
INCORRECT
ON
DC
POW
OF
Turn DC
power ON
26 support.hysecurity.com
INSTALLATION
Table 2. Menu Mode Navigational Buttons
To navigate through To choose what is on To navigate between
To edit the Menu
the SELECTIONS the display menus
Press NEXT.
Press SELECT. Press SELECT. Press NEXT or PREV.
Continue pressing
Two top characters blinking characters Advance - press NEXT.
NEXT to view all
blink. become static. Previous - press PREV.
selections.
S2 0
SENSOR #2 TYPE
Same as Sensor 1
S3 0
SENSOR #3 TYPE Same as Sensor 1
2. Hold the CLOSE button until the gate slides to LEARN CLOSE
full close. Release the CLOSE button and press INCHES: - XXX.X
STOP twice. The full close stop is retained in
memory.
OPEN CLOSE STOP MENU RESET
NOTICE
Pressing OPEN will reverse direction. PREV NEXT SELECT
NOTICE HYSECURITY
GATE CLOSED
NO AC POWER flashes after the gate status
display if the AC power has not been connected
or the lower power switch is turned off. OPEN CLOSE STOP MENU RESET
28 support.hysecurity.com
INSTALLATION
INSTALLING THE TARGET MAGNET CAUTION
1. With the gate CLOSED, mark the chain link To avoid damage to the idler wheel, the head
directly across from target sensor that is closest of the screw must be flush with the chain rollers.
to the trailing edge of the gate. See Figure 18.
FRONT INSTALLATION
(LH Gate Closed)
Roller chain sprocket
Target
Second target Sensor
sensor is not used (LH gate)
REAR INSTALLATION
(LH Gate Closed)
PUBLIC
Posi�on of the
OPEN target magnet
SECURE when the gate
Chain mo�on
is fully closed.
OPEN
30 support.hysecurity.com
POWER
INSTALLING THE EARTH GROUND Take the following steps to comply with NEC and
NFPA 780 standards:
An earth ground refers to the grounding rod and
accompanying equipment ground which need 1. Install a grounding rod per local building
to be installed to safeguard against potential codes. See Figure 21.
electrical shock and damage to personnel and 2. Attach a large earth ground wire (6 AWG) from
equipment. the grounding rod to the lug nut on the base
DANGER of the chassis.
WARNING
DO NOT connect the 115VAC service
outlet to 208/230VAC power supply
O
wires. To use the 115VAC service DC
POW
outlet on a 208/230VAC installation, OF
the electrician needs to run an extra
neutral wire to the operator from the
power source and wire the service
outlet per code.
Voltage selector
switch is factory
set to 115V.
Junc�on box
cover and label
If power input is 208/230V,
move the switch so 230V
appears and change the
label on the junc�on box
32 support.hysecurity.com
POWER
WIRING 115VAC POWER NOTICE
For standard 115VAC power connection: Table 4 assumes a dedicated circuit with an
• Verify AC power supply wires and low voltage accessory power load up to 2A. Additional
(12V & 24V accessory power wires) run through loads require that the wire size be increased
two separate conduits. The higher voltage from or the distance of the run be decreased.
the AC power supply may cause interference To connect to 115VAC power, take the following
and anomalies in SlideSmart operation if the steps:
high and low voltage wires are routed through
the same conduit. 1. Make sure the AC power is turned off at its
source and the DC and AC power switches on
• Maximum gate operator current draw is 3 Amps the operator are in the off position.
on a dedicated 115VAC circuit (20A dedicated
circuit is recommended). 2. Access the input power wires and service outlet
wires by removing the two Phillips-head screws
• Make sure proper wire size is used. Table 4 that secure the high voltage junction box cover.
shows the maximum allowable wire run from See Figure 22.
the power source to the operator for various
wire sizes. NOTICE
Table 4. Wire Gauge versus Run The service outlet wires are solid copper and
AC 14 ga. 12 ga. 10 ga. are labeled and bound together to keep them
separate from the AC power switch wires.
Power wire wire wire
One 3. Wire nut or crimp bond the power supply wires
730 ft 1200 ft 1900 ft to the black and white lead wires coming from
operator
(223 m) (366 m) (579 m) the AC power switch (no label). See Figure 22.
115V
Two 4. Wire nut or crimp bond the equipment ground
460 ft(140 750 ft (228 1160 ft
operators wire to the green ground wire in the junction
m) m) (354 m)
115V box.
5. To activate the 115VAC service outlet, include
the black and white outlet lead wires and the
green ground wire in the connections made
above.
6. Neatly organize all wire connections and
replace the high voltage junction box cover.
Secure it with the two Phillips-head screws.
34 support.hysecurity.com
POWER
USING A SOLAR POWERED OPERATOR DESIGN REQUIREMENTS &
CONSIDERATIONS
HySecurity offers a solar version of the SlideSmart
operator in 1ft/s or 2ft/s models. The solar Two standard 8Ah batteries are supplied with
models have different internal wiring and include SlideSmart DCS and nominally support up to 1,500
software programmed for solar use. The Smart DC feet of gate travel per day based on the following:
Controller has a builtin charger which allows a 24V
solar panel (or two 12V panels connected in series) • 20 WATT solar panel system (minimum
a direct connection to the SlideSmart operator requirement). See Figure 24 and "Figure 25.
with no additional electronic devices required. Solar Panels Wiring Connection" on page 37.
• Battery storage capacity based on 4 solar
NOTICE
hours per day. See "Figure 27. Solar Peripheral
Solar panels are NOT included in the purchase of Connections" on page 38.
the SlideSmart DCS 15 and 10F operators. Also,
• A gate weight of 1000lbs (454kg), gate length
adapting a standard SlideSmart DC operator
of 30ft (9m), and gate speed of 1ft/s (30.5cm/s)
to a solar application is not recommended. For
ease of installation and proper functionality, be • Connection of two Hy5B and one multi-code
sure to order a solar model, SlideSmart DCS, radio receiver. Note that if connected properly,
for a solar-powered site. photo eyes are not considered in the power load
because the Smart DC Controller only powers
To plan a solar-powered site, read through the photo eyes when the motor engages. Refer
this entire section. Keep in mind that the solar to "Monitored External Entrapment Sensors"
SlideSmart DCS operator does not have the on page 93.
following components:
NOTICE
• Transformer
The available 50Ah battery option supports up
• AC power supply board to 9,000 feet of gate travel per day.
• AC service outlet
The design of the solar-powered site is important
• Various wiring adaptations that are standard in in maintaining the highest gate cycle capacity
a SlideSmart DC operator and extending the life of the batteries. The
construction of a solar-powered gate and its cycle
capacity is significantly affected by the following:
• Energy demand of the peripheral devices. The
more energy efficient the device the less power
draw occurs to the batteries.
• Sun hours at the site. “Sun hours” relate to the
amount of energy delivered by the sun and
absorbed by the solar panels. It is NOT the same
as the number of daylight hours available at the
site. See Figure 28 on page 39.
• Design considerations must use calculations
that are figured for the darkest months of the
year (typically December/January). Higher
wattage panels may be required.
36 support.hysecurity.com
POWER
NOTICE 7. Turn both DC power switches ON and program
the Smart DC Controller. See Figure 26. See
For extended battery backup installation "Programming the Initial Setup Menu" on
instructions, refer to "Installing the Extended page 26.
Battery Backup Kit" on page 41.
Control Box
6. Slide the plastic cover off the control box and
attach the red spade connector to the battery
terminal on the upper DC power switch. See DC Ba�ery &
Motor
Figure 26. switch (OFF)
Red Spade
Connector
DC Solar Panel
24VD switch (OFF)
C
24VD
Input & C
ground wires
Green
Red
Black Figure 27. Solar Panels
24VAC
24VDC and 12VDC
1 AMP
MAX
NOTE: The 24VDC power supply has four terminals
12VDC
1 AMP
that can be used in any combina�on to draw the
MAX
available 1A maximum. The 12VDC has two terminals.
COM
COM
HY-5B
STOP INSIDE
LOOP
OPEN
CLOSE
RADIO
OPEN
OPEN
PARTIAL
SENSOR HY-5B
2 OUTSIDE
SENSOR
3 LOOP
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP USER 1
OUTOBS HY-5B
LOOP CENTER
CENTER LOOP
LOOP
SENSOR
SENSOR COM 1
terminal SENSOR
COM
+24V DC
Photo eye
USER2
24 VDC EMERG
+24V S1
OPEN B COM OPEN COM NO
COM A RADIO OPTIONS
SHOW DUAL GATE
LEDs
USB PORT RS-485
USER RELAY 1 USER RELAY 2 COMMUNICATION
Electromechanical Solid state
NOTE: Photo eyes connected to these terminals receive power when the motor engages which
means the draw on the ba�ery is minimal.
38 support.hysecurity.com
POWER
UNDERSTANDING GATE ACTIVITY BASED NOTICE
ON SOLAR ZONES
Remember, the sun is the only source of
Use the solar maps to determine the number energy. If you need to increase the amount
of solar hours per day that can be reasonably of gate travel per day (i.e. feet of gate travel),
expected in a particular zone. The number of solar additional solar panels may be required. Also,
hours per day affects the amount of gate travel the greater the battery capacity, the longer the
for a free-rolling gate powered by the SlideSmart operator can cycle the gate on cloudy days
solar operator. See Figure 28. without the recharge provided by the solar
panels. Sites requiring more than 1,500 feet
of gate travel per day or those sites located
in less sunny locales, need larger capacity
batteries and larger solar panels. HySecurity
offers a 50Ah battery option which provides
six times the storage capacity of the standard
8Ah batteries.
1.7
The chart is based on a 20 Wa� (24VDC) solar panel system
with SlideSmart powering a 30 foot (9m), 1000 lbs, 1�/s gate
with the following peripherals a�ached: This solar isola�on map recreated courtesy DOE.
The number of amps that the peripherals draw coupled with the gate travel
occurring throughout the night determines the battery capacity required.
The number of amps that the peripherals draw coupled with the gate travel during
the day, determines the solar panel size needed.
NOTE: HySecurity provides a 50Ah battery option for sites where high gate travel and
inclement weather are an issue. For sites of this nature, consider at least a 40W system. A
40W system doubles the feet of gate travel/day that is shown in the chart above.
40 support.hysecurity.com
POWER
INSTALLING THE EXTENDED BATTERY Screws
(x4)
BACKUP KIT
Control
Box
Post-mounted
operator with
base extension 8Ah ba�ery
HYSECURITY
GATE CLOSED
Black
Blue Figure 33. HySecurity Gate Closed
Red
BT 1 (EXTENDED)
BATTERY TYPE
42 support.hysecurity.com
DISPLAY AND MENU OPTIONS
This section of the manual provides information TURNING BOTH POWER SWITCHES ON
about the display and menu options. It includes
how to: AC and DC power switches are located on the
outside edge of the control box. See Figure 36.
1. Turn both AC and DC power switches on.
After "Programming the Initial Setup Menu" on
2. Review how to use the Smart DC Controller page 26, "Installing the Target Magnet" on
Buttons in Menu Mode page 29, and connecting to main power (Power),
3. Review Run Mode and Gate Status Displays take the following steps:
4. Access and Configure User Menu Options 1. Turn both power switches ON. The gate
moves and searches for the target magnet to
• Adjust the Close Timer re-establish the limits. An audible beep occurs
• Set the Time and Date and a red light pulsates next to the OPEN
• Set the AC Power Loss Gate Function button on the Smart DC Controller which
indicates the system is functioning. If AC power
• Adjust the Display Contrast is lost, the rate of flashing slows down. Other
5. Access and Configure Installer Menu Options indicator lights are described below.
• Reset the OPEN & CLOSE Limits NOTICE
• Set the Open and Close Gate Speed
If the target magnet is not detected by the
• Adjust IES Sensitivity operator, “ALERT 15 - NO TARGET” or
• Enable Fire Department Access “LEARN OPEN” appears on the display. For
• Reinstate Factory Defaults more information, refer to "Installing the
Target Magnet" on page 29.
INITIAL SETUP
2. When the target magnet is detected, the
Once you have completed the installation of
software version briefly appears on the display,
the SlideSmart operator and attached the wired
and then one of the following modes appears:
accessories, you’re ready to program the operator.
Two different approaches exist: • Gate status - indicates the operator is in Run
Mode. Refer to "Run Mode" on page 46.
• Connect a laptop computer to the USB or serial
(RS-232) port and upload the gate settings and • Alert, fault, and error messages - indicates
set the operator menu configurations via the a problem exists with the operator which
START software. needs to be resolved before the operator
can function properly. Refer to "Smart DC
NOTICE Controller Troubleshooting" on page 99.
Use a laptop computer at your place of
business to conveniently download the free
START software from www.hysecurity.com
before heading out into the field. This makes
it easy to adjust settings using a laptop.
MENU RESET
CLOSE STOP
OPEN
NEXT SELECT
PREV
44 support.hysecurity.com
DISPLAY AND MENU OPTIONS
USING THE SMART DC CONTROLLER • Run Mode - gate is operational awaiting
BUTTONS IN MENU MODE commands. Refer to Using the Smart DC
Controller Buttons in "Run Mode" on page
The buttons on the Smart DC Controller let you 46.
navigate, change, or clear the information in the
display menus. Refer to Figure 38. • Menu Mode - motor disengages and operator
commands are ignored. Data entry, menu
The buttons with text above and below have two navigation, and menu selection can be
functions. Use these buttons to enter operating accomplished via the Controller buttons or
commands or navigate through the User and through a START software connection using
Installer Menus. The singular use of these keys is the USB port.
dependent on the operator mode. Three different
modes exist: • Fault Mode - alerts, faults or errors appear
on the display. Some errors or faults can be
reset with the STOP button while more serious
faults require the RESET button or cycling
power. Faults indicate a need for diagnosis
and resolution. Refer to "Smart DC Controller
Troubleshooting" on page 99.
Pressing SELECT
causes the upper two characters to blink,
which indicates the display is ready to
accept changes to a menu setting.
GATE CLOSED
PREV NEXT SELECT
46 support.hysecurity.com
DISPLAY AND MENU OPTIONS
VIEWING OPERATOR STATUS DISPLAYS
Press the MENU button once and the operator status displays appear in two second intervals. Pertinent
information appears to provide a quick overview of the operator’s status or configurations. Refer to Table 7.
D <32>.0 VDC Number varies depending on voltage Displays actual charging voltage to
BATTERY VOLTAGE that charger is providing. batteries.
• Adjusting the Close Timer 3. To exit the User Menu, press the MENU
• Setting the Time & Date button. The gate status appears in the display
indicating you have returned to Run Mode.
• Setting the AC Power Loss Gate Function
• Adjusting the Display Contrast
For information on how the menu buttons CT 0 (OFF)
function, review "Using the Smart DC Controller CLOSE TIMER
Buttons In Menu Mode" on page 45.
48 support.hysecurity.com
DISPLAY AND MENU OPTIONS
SETTING THE TIME AND DATE A gate status appears in the display indicating
you have returned to Run Mode.
A feature of the Smart DC Controller is its 24-hour,
365 day clock. Make sure it is set to the appropriate 1. Start at a gate
status display.
time zone. An accurate time and date allows the HYSECURITY
diagnostic log to date stamp operational data GATE CLOSED
2. Press NEXT or PREV until the SET CLOCK PREV NEXT SELECT
display appears.
3. Press SELECT. CL blinks.
3. Press NEXT until
4. Press NEXT or PREV to change the number the SET CLOCK
CL 1 display appears.
to 1. SET CLOCK Use the
5. Press SELECT to accept the display. navigational
buttons to select
OPEN CLOSE STOP MENU RESET 1.
6. The date and time display appears. Use the
SELECT and NEXT buttons in the same manner PREV NEXT SELECT
as before to adjust the date and time.
NOTICE
4. Change the time
A date or time field must be blinking before it and date using
can be changed. 08/01/21
08/01/18 00:00 the NEXT and
^^ SELECT buttons.
7. To accept what appears on the date and time
display, press SELECT. OPEN CLOSE STOP MENU RESET
8. To exit the User Menu, press the MENU button. PREV NEXT SELECT
50 support.hysecurity.com
DISPLAY AND MENU OPTIONS
To designate what you want operator to do during ADJUSTING THE DISPLAY CONTRAST
an AC power loss, access User Menu (see "User
Menu" on page 48 and Figure 43) and scroll The display contrast can be adjusted from 1 to 9
through items until AP (AC LOSS) display appears: to increase visibility and ease of use. It is set at the
factory to level 5. The text becomes darker as you
1. Use SELECT and NEXT buttons to navigate go up the scale.
and change number on display. Review Using
the "Using the Smart DC Controller Buttons
In Menu Mode" on page 45. To adjust the contrast (1 to 9), take the following
2. To exit User Menu, press MENU button. A gate steps and see Figure 44:
status appears in display indicating you have 1. At a gate status display, press the MENU
returned to Run Mode. button twice. This accesses the User Menu and
the CLOSE TIMER display appears.
52 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Table 9. Smart DC Controller - User Menu Functions
Setting Options Associated
Ref. User Menu
(Bold = Factory Menu Tasks and Explanations DC Controller
No. Display
Settings) Connections
BF 2 (ON 2 SEC) Controls warn-before-operate (N/A)
WARN BEFORE OPER buzzer and can be configured WARNING:
three ways: Do NOT
Set to 0: Buzzer is disabled. Set at cut wires
0, buzzer will still beep when alerts, to buzzer
faults, errors, or entrapment are or unplug it
0 = off detected. as operator
6 1 = on Set to 1: Buzzer beeps for 3 will not be in
2 = on seconds before gate motion compliance
begins and continues through with UL 325.
entire gate travel. Failure to
Set to 2: Buzzer beeps for 3 comply may
seconds before gate motion result in
begins and continues for 2 serious injury
seconds of gate travel. or death.
When set to 1, operator serves
PE 0 (OFF)
PHOTO EYE ALIGN as an aide in photo-eye emitter/
receiver alignment. Buzzer chirps Sensor
once when emitter and receiver Common,
0 = off are not aligned. When emitter and Sensor 1,
7
1 = on receiver are aligned, buzzer chirps
twice. If they go out of alignment Sensor 2,
again, buzzer will chirp once. Sensor 3
Alignment Mode is reset with a
limit input or reset input.
To set or adjust minute, hour, day,
CL 0
SET CLOCK month or year, select 1. Once clock
is set, display automatically returns
to 0 setting. Significant gate events
are logged and stamped with time
0 = Display and date. This feature is useful
8 (N/A)
1 = Set Clock to read historical operation data,
which can be accessed with a
computer via USB or RS232 port or
the LG setting in User Menu. See
"Setting the Time and Date" on
page 49.
54 support.hysecurity.com
DISPLAY AND MENU OPTIONS
In the following pages, a detailed view of the more 1. Start at a gate status display. To bypass the
commonly used Installer menu items is provided. Operator Status Displays, press the MENU
button twice. See Figure 45.
• Resetting the OPEN & CLOSE limits
• Adjusting the Gate Speed
• Adjusting the IES Sensitivity HYSECURITY
GATE CLOSED
• Enabling the Fire Department Override
• Reinstating Factory Defaults
OPEN CLOSE STOP MENU RESET
"Table 10. Smart DC Controller - Installer Menu
Functions" on page 62 describes Installer
Menus items show factory defaults, and references PREV NEXT SELECT
1. At a gate status display, press the MENU button PREV NEXT SELECT
5. Press STOP twice to preserve the full open PREV NEXT SELECT
RESET
position; LEARN CLOSE appears on the buttons.
display.
6. Hold the CLOSE button until the gate slides
4. Press SELECT
to full close. Release the CLOSE button (Note LL 1 (ON) and change the
that if you go too far, you can press OPEN to LEARN LIMIT setting to 1
using the NEXT
reverse direction.) button. Press
OPEN CLOSE STOP MENU RESET
SELECT again.
7. Press STOP twice. The full close position is PREV NEXT SELECT
The LEARN
retained in memory. For more information, OPEN display
appears. Refer
refer to "Establishing the Open & Close Limits" to steps 4 to 8.
on page 28.
Figure 49. Resetting OPEN and CLOSE Limits
56 support.hysecurity.com
DISPLAY AND MENU OPTIONS
ADJUSTING GATE SPEED 1. Start at a gate
status display.
The gate speed can be increased or decreased HYSECURITY
a ¼ foot per second from the operator’s default GATE CLOSED
speed. See Figure 49
OPEN CLOSE STOP MENU RESET
NOTICE
PREV NEXT SELECT
Two options, one for OPEN SPEED the other
for CLOSE SPEED, appear in the Installer
Menu. The steps involved in changing the
open speed are shown below. The steps to set
the close speed are the same, you just need
to access the CLOSE SPEED option.
2. To access the
To adjust the gate speed, take the following steps: User Menu,
CT 0 (OFF) press the MENU
1. At a gate status display, press the MENU button CLOSE TIMER button twice.
twice. The CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET OPEN CLOSE STOP MENU RESET
buttons to enter the Installer Menu. Release
the buttons and the LEARN LIMITS display PREV NEXT SELECT
appears. It is the first item in the Installer Menu.
3. Press NEXT until the OPEN SPEED (or CLOSE
SPEED) display appears. Select the desired
setting based on the operator type:
3. Access the
SlideSmart DC 15 0 = 0.75 ft/s Installer Menu, by
LL 0 (OFF) simultaneously,
1 = 1.0 ft/s LEARN LIMIT pressing the
(Usage Class 3 & 4 only) 2 = 1.25 ft/s OPEN and
RESET
OPEN CLOSE STOP MENU RESET buttons.
SlideSmart DC 10F 4 = 1.75 ft/s
(The DC 10F is designed for 5 = 2.0 ft/s PREV NEXT SELECT
Usage Class 3 & 4 sites only) 6 = 2.25 ft/s
NOTICE
Certain speeds are allowed only when the
operator’s Usage Class is set appropriately.
4. Use NEXT to
4. Use the SELECT and NEXT buttons to navigate OS 5
navigate to the
and change the speed setting on the display. menu display.
OPEN SPEED Change the
5. To exit the Installer Menu, press the MENU setting using the
button. The gate status appears in the display SELECT and
OPEN CLOSE STOP MENU RESET NEXT buttons.
indicating you have returned to Run Mode.
PREV NEXT SELECT
Avoid setting the IES sensitivity to a fixed level automacally increases by 50% when the temperature drops below 32°F.
(7 - 9 setting). The high motor current required Figure 52. IES Sensitivity
for the IES to trip could cause severe injury or
death to people caught in the moving gate. NOTICE
For IES settings (0 through 6), the motor current is When changing the IES setting, consider the
continually being measured and the IES threshold site design and vehicular gate traffic. It is
automatically set to trip at the average current recommended that you use the most sensitive
plus the additional “headroom” provided by the setting while still allowing for reliable gate
IES setting selected. operation.
To prevent false IES trips, the software boosts the Examples of conditions which affect IES sensitivity
IES current threshold for one gate cycle after an include:
IES event, then returns to the normal sensitivity
Gate design - For long and/or solid gates in windy
threshold.
environments, large variations in motor current
Over time, degrading gate hardware and other may occur. In these types of scenarios, you may
site issues, such as road settling or debris on the want to use a higher (less sensitive) IES setting.
gate rail (V-track) can occur. As the gate hardware
Gate condition - If the gate environment is near
ages and becomes stiffer, the SlideSmart motor
salty sea air, rusty wheels or chains might impede
current increases and this may create the need to
gate travel over time. Additionally, gates that are
use a higher IES setting level. The higher settings
hit and bent may have very stiff areas during travel
should only be used on a TEMPORARY basis until
that cause a large variation in motor current. For
the gate, gate track, or wheels are repaired so the
these issues, you may want to use a higher (less
gate rolls smoothly with minimal resistance.
sensitive) IES setting until repairs are made.
58 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Gate maintenance - Gate rollers will deteriorate 1. Start at a gate
and begin to fail over time. Gravel or dirt roads status display.
will incur more debris in the gate rail or inverted HYSECURITY
V-track than a paved surface. In poorly maintained GATE CLOSED
gate areas, the chance for false IES trips is higher.
OPEN CLOSE STOP MENU RESET
To adjust the IES sensitivity, take the following
steps and see Figure 52: PREV NEXT SELECT
Avoid setting the IES sensitivity to a fixed level PREV NEXT SELECT
(7 - 9 setting). The high motor current required
for the IES to trip could cause severe injury or
death to people caught in the moving gate.
4. Use the SELECT and NEXT buttons to navigate
and change the number on the display. 3. Access the
Installer Menu, by
5. To exit the Installer Menu, press the MENU LL 0 (OFF) simultaneously,
button. The gate status appears in the display LEARN LIMIT pressing the
indicating you have returned to Run Mode. OPEN and
RESET
If IES trips occur, SAFE MODE or ENTRAPMENT OPEN CLOSE STOP MENU RESET buttons.
MODE will appear on the display. For more
information about troubleshooting, refer to "Table PREV NEXT SELECT
16. Smart DC Controller - Troubleshooting" on
page 99.
4. Use NEXT to
navigate to the
SE 2 menu display.
IES SENSITIVITY Change the
setting using the
SELECT and
OPEN CLOSE STOP MENU RESET NEXT buttons.
customer’s needs.
PREV NEXT SELECT
CAUTION
Reinstating factory default clears ALL menu
settings stored in the operator and returns
them to factory defaults. It is recommended
that you save the menu settings before 2. To access the
reinstating factory defaults. You can write the User Menu,
settings in a notebook or, if you have a laptop CT 0 (OFF) press the MENU
CLOSE TIMER button twice.
computer, you can use HySecurity’s START
software and download the menu settings and
save them to a file to upload to the operator OPEN CLOSE STOP MENU RESET
at a later date.
PREV NEXT SELECT
To reinstate factory defaults, take the following
steps and see Figure 53:
1. At a gate status display, press the MENU
button twice. This accesses the User Menu and
the CLOSE TIMER display appears. 3. Access the
Installer Menu, by
2. Simultaneously, press the OPEN and RESET LL 0 (OFF) simultaneously,
LEARN LIMIT pressing the
buttons to enter the Installer Menu. Release
OPEN and
the buttons and the LEARN LIMITS display RESET
appears. It is the first item in the Installer Menu. OPEN CLOSE STOP MENU RESET buttons.
3. Press NEXT until the FACTORY DEFAULTS
PREV NEXT SELECT
display appears. The factory default setting
is 0.
4. Use the SELECT and NEXT buttons to navigate
and change the number on the display to 1.
NOTICE 4. Use NEXT to
When you press SELECT to accept FD 1, the navigate to the
FD 1 (ON) FD menu display.
factory settings are reinstated immediately and FACTORY DEFAULTS Change the
the menu display returns to the initial Setup setting using the
Menu. The gate operator will not run until the SELECT and
three menu parameters are entered: Usage OPEN CLOSE STOP MENU RESET NEXT buttons.
Class, Gate Handing, and Gate Weight along
PREV NEXT SELECT
with Sensor 1, 2, and 3. The limits will also
need to be relearned. Refer to "Programming
the Initial Setup Menu" on page 26 and
"Establishing the Open & Close Limits" on
page 28. Figure 54. Reinstating Factory Defaults
60 support.hysecurity.com
DISPLAY AND MENU OPTIONS
ENABLING THE FIRE DEPARTMENT 1. Start at a gate
OVERRIDE status display.
HYSECURITY
Many counties and cities require a Fire Department GATE CLOSED
override system for gate operators. The fire
department’s alert system is a separate unit that OPEN CLOSE STOP MENU RESET
STOP
4. Use NEXT to
OPEN navigate to the
CLOSE FO 1 menu display.
RADIO
OPEN
OPEN
PARTIAL
FIRE DEPT OPEN Change the
EYE
OPEN
EYE
CLOSE
setting using the
EXIT
LOOP SELECT and
BLOCK
EXIT OPEN CLOSE STOP MENU RESET NEXT buttons.
IN OBS
LOOP
OUTOBS
LOOP
FIRE CENTER
LOOP
EDGE
PREV NEXT SELECT
EYE
COM
+24V
EMERG
OPEN
SHOW
LEDs
62 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Setting Options DC Controller
Ref. User Menu
(Bold = Factory Menu Tasks and Explanations Display
No. Display
Settings) Connections
OS 5 Designates how quickly gate
OPEN SPEED DC 15 opens. Options available differ
0 = 0.75 ft/s depending on Operator Type (OT).
1 = 1.0 ft/s SlideSmart has two operator types:
2 = 1.25 ft/s OT15 ≤1.25ft/s and OT16 ≥ 1.75ft/s. (N/A)
5
DC 10F Settings higher than 1 are reserved
4 = 1.75 ft/s for Usage Class 3 and 4.
5 = 2.0 ft/s
6 = 2.25 ft/s NOTE: SlideSmart DC15 = OT 15
and SlideSmart DC10F = OT16.
Designates how quickly gate
CS 5
CLOSE SPEED
DC 15 closes. Options available differ
0 = 0.75 ft/s depending on Operator Type (OT).
1 = 1.0 ft/s SlideSmart has two operator types:
2 = 1.25 ft/s OT15 ≤1.25ft/s and OT16 ≥ 1.75ft/s. (N/A)
6
DC 10F Settings higher than 1 are reserved
4 = 1.75 ft/s for Usage Class 3 and 4.
5 = 2.0 ft/s
6 = 2.25 ft/s NOTE: SlideSmart DC15 = OT 15
and SlideSmart DC10F = OT16.
FD 0 (OFF) Globally restores all menu settings
FACTORY DEFAULTS back to new operator status. Select
0 = custom user setting 1 to return operator to
settings factory defaults.
7 1 = reload NOTE: If factory defaults are (N/A)
factory default restored, the UL usage class,
settings handing, gate weight, and any
other modified menu settings will
need to be reprogrammed.
DG 0 (OFF) 0 = solo Configures gate operator as a *Use shielded cable
DUAL GATE
operator Primary or as a Secondary in a to DUAL GATE input
dual-gate installation. When you terminals. Connect
1 = Secondary assign one unit as Primary, you D u a l G a t e C O M
unit must configure other as Secondary (Gate 1) to Dual Gate
8
through Installer Menu. This menu COM (Gate 2). Pair
2 = Primary unit
is also used to configure a Sally Port wires: A - A, COM -
3 = Sally Port A system by setting one operator to COM, and B - B. Dual
Sally Port A and the other to Sally Gate wiring requires
4 = Sally Port B Port B. 3 wires.
*NOTE: Use a 2-pair, twisted, shielded cable with one pair of wires used to connect A-A and B-B
terminals between the two boards. The other pair will connect the Common terminals. The shield
should then be grounded on only one end to one of the operators.
64 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Setting Options DC Controller
Ref. User Menu
(Bold = Factory Menu Tasks and Explanations Display
No. Display
Settings) Connections
SS 0 (OFF) 0 = stop, In a Usage Class 4 environment,
IES STOP ONLY
reverse for 2s operator can be set to stop gate
14 (N/A)
and not reverse gate travel after
1 = stop only an IES trip.
LC 0 (0.0 SECS) 0 = no delay
LEAF DELAY CLOSE
Only appears if the gate operator is
1 through 20 set up as a Primary or a Secondary.
in ½ second Available settings are 1 through
increments 20. Each increment adds ½ second DUAL GATE inputs
15
time delay following a command to on both operators
For example:
close before the operator activates.
1 = ½ second
Provides up to a 10 second time
10 = 5 seconds
delay.
20 = 10 seconds
LO 0 (0.0 SECS) 0 = no delay
LEAF DELAY OPEN
Only appears if the gate operator is
1 through 20 set up as a Primary or a Secondary.
in ½ second Available settings are 1 through
increments 20. Each increment adds ½ second DUAL GATE inputs
16
time delay following a command to on both operators
For example:
open before the operator activates.
1 = ½ second
Provides up to a 10 second time
10 = 5 seconds
delay.
20 = 10 seconds
RT 0 (60 SECS) Doesn't appear in SlideSmart.
MAXIMUM RUN TIMER 0 = 60 Seconds Assigns a motor run time of 60 or
max run, 300 seconds. If the gate opening
17 (N/A)
1 = 300 Seconds or closure takes longer than 60
max run seconds, you’ll need to set the run
timer to 1.
PO 0 (OFF) Sets distance (from closed gate
PARTIAL OPEN 0 = OFF position) where gate stops if the
7 = 7 ft, 8 = 8ft, partial open input is activated.
18 OPEN PARTIAL COM
through 32 = 32 When a number is entered in
ft PO display, open partial input
becomes operational.
EC 0 (STOP ONLY) Default setting is non-reversal if
0 = Close eye
EYE CLOSE LOGIC close photo eye is triggered while
stops only
closing. A setting of 1 causes gate Sensor Common
19 1 = 2s reverse to to reverse toward open for two
open seconds if triggered while closing. Sensor Input
A setting of 2 reverses the gate to
2 = Full Open
full open.
66 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Setting Options DC Controller
Ref. User Menu
(Bold = Factory Menu Tasks and Explanations Display
No. Display
Settings) Connections
S1 0 0 - disabled
SENSOR #1 TYPE UL 325 - 2018 sensor input setting
1 - (NOT USED) for external entrapment protection
2 - (EYE CLOSE) sensor monitoring. All three sensor
inputs must be configured to a
3 - (EDGE CLOSE non-zero number before the gate
25
4 - (EYE OPEN) operator will move the gate. Edge
Both is only available in Swing Gate
5 - (EDGE OPEN) operator types. Eye Both is only
6 - (EDGE BOTH) available in Slide Gate operator
types.
7 - (EYE BOTH)
S2 0
SENSOR #2 TYPE
26 Same as Sensor 1 Same as Sensor 1
S3 0
SENSOR #3 TYPE
27 Same as Sensor 1 Same as Sensor 1
68 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Setting Options DC Controller
Ref. User Menu
(Bold = Factory Menu Tasks and Explanations Display
No. Display
Settings) Connections
RL 1 0 DISABLED Configures function of the
RELAY 1 LOGIC user 1 output relay, which is an
electromechanical relay. It has
capacity to switch, both AC and
DC and can be used for high
0 = default voltage and/or high current loads.
32 Connect devices directly to the User 1 Relay
1 to 45 available
top of relay: COM plus NO and
NC contacts. Up to 45 optional
relay functions exist.
See "Figure 53. Reinstating
Factory Defaults" on page 60.
RL 2 1 CLOSE LIMIT Configures function of user
RELAY 2 LOGIC
2 output relay, which is an
electronic relay with capacity for
switching a DC load only. The
0 = default
33 User 2 Relay is limited to 48 Volts User 2 Relay
1 to 45 available DC and 4A maximum load. Up to
45 optional relay functions exist.
See "Figure 53. Reinstating
Factory Defaults" on page 60.
RL 3-10 1 CLOSE LIMIT Similar to Relay 1 Logic.
RELAY 3-10 LOGIC
70 support.hysecurity.com
DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Setting Options DC Controller
Ref. User Menu
(Bold = Factory Menu Tasks and Explanations Display
No. Display
Settings) Connections
ILD 0 (RUN MODE) 0 = Run mode
IN OBS LOOP SET
1 = Show
frequency Controls Hy5A or Hy5B Inside
Obstruction Loop detector. If an
39 2 = Show call Hy5B
Hy5B is used, additional settings
level 0-7 of 4-8 are available.
3 = Set
Frequency
OLD 0 (RUN MODE) 0 = Run mode
OUT OBS LOOP SET
1 = Show
frequency Controls Hy5A or Hy5B Outside
Obstruction Loop detector. If an
40 2 = Show call Hy5B
Hy5B is used, additional settings
level 0-7 of 4-8 are available.
3 = Set
Frequency
CLD 0 (RUN MODE) 0 = Run mode
CENTER LOOP SET
1 = Show
frequency Controls Hy5A or Hy5B Center
Loop (Shadow) detector. If an
41 2 = Show call Hy5B
Hy5B is used, additional settings
level 0-7 of 4-8 are available.
3 = Set
Frequency
DC POWER
SWITCH
AC POWER
SWITCH
72 support.hysecurity.com
SMART DC CONTROLLER
OVERVIEW OF THE SMART DC CONTROLLER
The Smart DC Controller uses LED’s to indicate active inputs when AC power is present. For operators
that use only DC power, you can push a button to show the active inputs. This button is at the bottom
left corner near the EMERG OPEN input.
On a new operator no active inputs should appear until external accessories and wiring are attached. If
any inputs are active before connecting external wiring, refer to "Smart DC Controller Troubleshooting"
on page 99.
Amp Draw on Power Supplies
Two power supplies are available:
24VDC and 12VDC
A maximum draw of 1A is available
for each power supply.
For example:
Amp Draw & Accessories connected to 24VDC
0.50A = Four photo eyes (for entrapment protection)
24VDC
COM 0.25A = Keypad with light
COM
24VDC
0.75A
COM
COM
COMMON HY-5B
COM
TERMINALS 12VDC
FREE EXIT
COM 12VDC
COM
COM
HY-5B
STOP INSIDE LOOP
OPEN
CLOSE
RADIO
OPEN
OPEN
PARTIAL
HY-5B
SENSOR
2 OUTSIDE
SENSOR LOOP
3
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUTOBS 1
HY-5B
USER RELAY l
LOOP
Electro-mecha
nica CENTER
CENTER LOOP
LOOP
SENSOR
1
SENSOR
COM
+ 24 V
USER2
DC
EMERG
OPEN OPEN +24V S1 COM NO
COM A B COM
SHOW DUAL GATE
RADIO OPTIONS
LEDs
USB RS-485
USER PORT COMMUNICATION
Press button to RELAY
light active inputs 2
Solid state
74 support.hysecurity.com
SMART DC CONTROLLER
Table 11. Smart DC Controller Board Inputs
Outside
Vehicle detector, box type
Obstruction
19 N.O. input. Outside reversing loop. connections outside reversing
Vehicle
loop
Detector
N.O. input. Shadow function used for swing
Center gates or Reset Loop for barrier arms only.
Vehicle detector, box type
Loop However, User Relay 20 can be used in
connections. Shadow function
20 (Shadow) combination with a detector to perform
for swing gates, reset function
Vehicle an "arming loop" or "annunciation loop"
for barrier arm gates.
Detector function because there is no associated gate
control logic in a slide gate.
N.C. input. Connection of a Monitored
External entrapment sensor
21 Sensor 1 Entrapment sensor. Type of sensor is
connections.
programmable in the Installer Menu (S1)
External Entrapment Sensor common wires
must be connected to this terminal, the
Sensor sensors are energized when AC Power is This terminal is used to perform
22
Common present. The devices are then checked for monitored entrapment check.
presence and correct operation when the
open limit is reached.
Convenient 24VDC power for
Convenient 24VDC power for accessories or
23 +24V DC photo eyes or Emergency Open
the Emergency Open input.
input.
Emergency Open must be
Emergency enabled via Installer Menu. It
Open is energized by connecting to
24 N.O. input.
(Fire Dept. +24V terminal above it. EMERG
Open) *** OPEN overrides photo eye &
edge sensor commands.
*Do not connect an external control to the STOP or OPEN inputs unless the controls are located in
clear view of the entire gate area and at least 6' away from any part of the moving gate..
**Use the RADIO OPEN input or RADIO OPTIONS spade connections for all out-of-sight controls,
such as a telephone entry or radio operated controls.
***The Fire Department Open control must be keyed or guarded so that it can only be used by
authorized personnel.
Vehicle Loop
features and
functions
Metal Pins fit explained
into controller on front label
board socket
76 support.hysecurity.com
SMART DC CONTROLLER
There are four vehicle detector inputs available 5. Repeat Steps 1 through 3 for each Hy5B
on the Smart DC Controller: detector.
• Free Exit Loop Detector - This opens a fully 6. To enable the detectors, turn on power. The
closed gate or reopens a closing gate. detectors will immediately tune if they are
connected to loops. Make sure no cars or other
• Outside Obstruction Loop Detector (Out Obs
metal objects are over the loops.
Loop) - Reversing loop on public side
7. If the detector module is unplugged after it
• Inside Obstruction Loop Detector (In Obs Loop)
is enabled, a communications alert (ALERT
- Reversing loop on secure side
10) will be triggered; if the fault continues an
• Center Loop Detector - Not used for slide gates. error message, ERROR 3 “Detector Failed” is
displayed.
NOTICE
NOTICE
Standard box type 11 pin (24 Volt DC or 24 Volt
AC) vehicle detectors may be connected in the If there is any detector fault, the gate operator
traditional manner as described in "Installing functions as if the detector is triggered.
Standard 11-Pin Box Type Vehicle Detectors"
on page 79. Pressing the RESET button:
• Clears any errors
CONNECTING HY5B VEHICLE DETECTORS • Tunes the detectors on connected loops
• Un-installs any detectors that have been
Install the Hy5B Vehicle Detector modules
removed
according to the following procedure:
8. The Smart DC Controller automatically sets
1. Turn off both AC and DC power switches. frequency for all Hy5B detector modules. This
2. Insert the locking end of the two white plastic simplifies installation and guarantees that
standoffs into the mounting holes on the there is no cross-talk between multiple loops.
detector. The frequency can also be manually selected;
if this is required, refer to "Table 10. Smart
3. Plug the detector into the appropriate DC Controller - Installer Menu Functions" on
socket along the right edge of the Smart DC page 62.
Controller board. Be careful to align the six
detector pins into the socket correctly (the NOTICE
Hy5B label should face toward the board), and Do not exceed more than 200 square feet (61
then snap the standoffs into the holes in the square meters) of loop area to one detector.
control box.
4. Route the loop wires through the holes
provided in the control box and connect the
loop leads to the two terminals on the Hy5B
detector.
NOTICE
Refer to the the Hy5B instructions for all the options
available for each individual Hy5B installed.
78 support.hysecurity.com
SMART DC CONTROLLER
INSTALLING STANDARD 11-PIN BOX TYPE 2. Connect 24 Volt power to the detector.
VEHICLE DETECTORS Connect Pin No. 1 to a 24VAC or 24VDC
terminal and Pin No. 2 to common.
NOTICE
3. Connect output Pin No. 6 to the Common
If photo eyes are used to monitor vehicle traffic Bus and output Pin No. 5 to one of the four
instead of loop detectors, connect the photos detector terminal inputs (depending upon the
eyes using the same steps. detector function required) on the Smart DC
Controller.
If standard 11-pin box type vehicle detectors are 4. If multiple detectors are used, route the power
to be used, perform the following procedure. wires and common wire from socket to socket
1. If there is sufficient space, install the sockets (daisychaining) rather than individually running
in the control box; if not, then install them in each wire to the same location. See Figure
a separate external housing. Figure 59 is for 59. The only wires that are separate are the
general reference only. output wire to the Smart DC Controller and
the detector loop input wires.
NOTICE
NOTICE
Carefully consider your peripheral connections.
Any peripheral device required for safe gate Always keep the detector loop wires well
operation should be attached 24VDC in case twisted at all places beyond the area of the
of an AC power outage. Additionally, box loop. The lead in portion sealed in a saw cut
detectors with relays require five times more does not need to be twisted so long as the
power than Hy5B detectors. UPS battery life wires are encapsulated in loop sealant and
will be extended if you use Hy5B detectors cannot move. Refer to "Installing Vehicle
instead. Detectors and Loops" on page 90.
PIN 2
PIN 1
24VAC or 24VDC
Connect detector to match
its voltage rating
Inside Outside
Free Exit Obstrucon Obstrucon Center
Loop Detector Loop Detector Loop Detector Loop Detector
24VDC
COM
24VDC
COM
COM
COM
COMMON HY-5B
COM
TERMINALS 12VDC
FREE EXIT
COM 12VDC
OPEN
OPEN
PARTIAL
Photo eye N.C. HY-5B
SENSOR
connects to either 2 OUTSIDE
Sensor 2 SENSOR LOOP
3
or Sensor 3 EXIT
LOOP
SENSOR COM
DC
EMERG
Relay COM OPEN B COM
OPEN +24V S1
COM NO
COM A
EYE OPEN or CLOSE SHOW DUAL GATE
RADIO OPT
IO NS
LEDs
(depending on function) USB RS-485
USER PORT COMMUNICATION
Press button to RELAY
light active inputs 2
Solid state
80 support.hysecurity.com
SMART DC CONTROLLER
MANUAL PUSH BUTTON STATION
A manual push button station controls the gate operator and opens, stops, and closes the gate. It is most
often used by a guard in a 24-hour guard station. An example of the push button station connections
on SlideSmart is shown in Figure 61.
CAUTION
Make sure the manual push button station is within site of the gate, a distance (six foot minimum)
away from the gate’s moving parts, and out of reach of children.
24VDC
COM
24VDC
COM
COM
COM
COM 12VDC
COM 12VDC
COM
COM
NO
OPEN STOP
OPEN
CLOSE
NO
RADIO
OPEN
CLOSE
OPEN
PARTIAL
SENSOR
2
SENSOR
3
STOP NC EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
Push Buon Staon OUTOBS
LOOP
CENTER
LOOP
SENSOR
3
SENSOR
COM
+24V
EMERG
OPEN
SHOW
LEDs
Use the Smart DC Controller buttons to program the user relays according to the following steps:
1. Select and connect to the relay you wish to use on the Smart DC Controller board.
2. Access the Installer Menu and RL 1 or RL 2 display (depending on the relay you have connected).
3. Enter the appropriate function using the associated number (1 through 45) listed in the table.
82 support.hysecurity.com
SMART DC CONTROLLER
Table 13. User-Programmable User Relays - Function Options
No. Name Description
Activates when gate is open longer than the user-selected period of time.
Gate open too long Adjustable from a 0 second to 135 seconds delay in 15-second increments.
8
output NOTE: TL - OPEN TIME ALERT adjustments can be made in Installer
Menu.
Activated when system is in Safety Mode or Entrapment Mode. Safety
Safety Mode Alert Mode occurs upon an impact with an obstruction. Entrapment Mode
9
output means gate is stopped and occurs if inherent entrapment sensor triggers
while system is in Safety Mode.
Entrapment Mode
10 Activated only when system is in Entrapment Mode.
Alert output
Activated when a second vehicle enters from outside without a valid
input from an access control device. The OOLD and IOLD loops must be
Unauthorized Vehicle
11 capable of being triggered at the same time for this relay to ever activate.
Entry output
This output releases when an access control input signals open or gate
reaches the close limit position.
Outside Obstruction
This output is active whenever Outside Obstruction Loop Detector is
12 Vehicle Detector
tripped. Interlocks an entry device to prevent pedestrian use.
output
Indicates vehicle is loitering on Outside Obstruction Loop with the gate
13 Loitering Alert closed. Adjustable from 0 second to 135 second delay in 15-second intervals.
NOTE: LT - LOITERING ALERT adjustments can be made in Installer Menu
Activated when gate is approaching full open or full closed. Relay
Gate nearing full travel activates three feet from where software expects limit switch to be
14
output triggered whether moving toward full open, full close, or in a reverse
travel mode.
Activated to report occurrence of problem. Indicates system is in an Error,
15 Gate Failure output
Fault, Alert, or Entrapment Mode. If active, gate is disabled.
16 Motor Running output Active when motor is running and gate is in motion.
AC Power Failure
17 This relay is normally energized and drops with loss of AC power.
output
DC Power Failure Activated when battery power is very low, but output ceases when battery
18
output is dead (18 volts). Relay is triggered when battery is less than 21 volts.
Controls flashing lights to pulse once per second. Relay is constantly
19 Flasher Relay pulsing except when open limit switch is triggered. Recommended to
use User Relay 2 since it is an electronic switch
Free Exit Loop Vehicle
20 Active whenever Exit Loop is tripped.
Detector output
Inside Obstruction
21 Vehicle Detector Active whenever Inside Obstruction Vehicle Detector is tripped
output
Center Loop Detector
22 Active whenever Center (Shadow) loop detector is tripped.
output
84 support.hysecurity.com
BI-PARTING GATE SYSTEMS
Configuring two operators to be a Primary • External control inputs, vehicle detectors and
and Secondary pair is easy with the Smart DC external entrapment sensors may be connected
Controller. There is no need to order a special to either gate operator without regard to
model or any adapters. The area of the board preference.
marked Dual Gate employs a 3-wire RS-485 serial • Be sure both operators are running the same
port for communication between primary and software version. The software version is
secondary operators. See Figure 62. available on the display by pressing the RESET
POWER REQUIREMENTS button on the operator. The software version
appears beneath the word HYSECURITY. Keep
When installing a dual-operator system, the the most current software loaded. It is available
following must be adhered to: at www.hysecurity.com. Make it part of your
maintenance routine to check for software
• An electrical conduit for interconnecting wires upgrades on a regular basis.
must span between the two operators. The dual
gate communication wires and any low voltage • Both operators can be connected to the same
control wires must be installed in a conduit that 20A circuit breaker in the main panel. The wire
is separate from the high voltage power wires. size affects operator performance. Use the
See Figure 63. following chart as a guideline to size wire for
the given distance from the power source to
• Complete the installation of both operators as BOTH operators.
separate machines and verify that their basic
functions are correct as solo operators before
interconnecting them.
SENSOR
COM
+24V DC ONLY
USER2
Primary Secondary
EXIT EXIT
LOOP LOOP
BLOCK BLOCK
EXIT EXIT
IN OBS IN OBS
LOOP USER 1 LOOP USER 1
OUTOBS OUTOBS
LOOP LOOP
CENTER CENTER
LOOP LOOP
SENSOR SENSOR 1
1
SENSOR SENSOR
COM COM
+24V DC +24V DC
USER2
USER2
EMERG A
EMERG
OPEN +24V S1 COM A B COM NO OPEN +24V S1 COM A AB COM NO
COM OPEN DUAL GATE COM OPEN DUAL GATE
SHOW RADIO OPTIONS SHOW RADIO OPTIONS
LEDs LEDs
NOTICE
Use a 2-pair, twisted, shielded cable with one pair of wires used to connect A-A and B-B terminals
between the two boards. The other pair will connect the Common terminals. The shield should
then be grounded on one end to one of the operators.
86 support.hysecurity.com
BI-PARTING GATE SYSTEMS
PRIMARY AND SECONDARY MENU SETUP once the Installer Menu is properly configured
Determine which unit will be set up as the Primary. in both units.
The other unit will be set up as the Secondary. It • A diagnostics log is maintained in each unit, but
doesn’t matter which unit is which, but you must both units run and store the errors codes and
identify the Primary and Secondary operators by diagnostics pertinent to each other.
taking the following steps and Figure 64:
• The primary unit controls the close timer even if
Start by configuring the PRIMARY unit. the timer is set in the slave unit. If a close timer
is set in both units, the primary unit overrides
1. At a gate status display, press the MENU the secondary setting.
button twice. This accesses the User Menu and
the CLOSE TIMER display appears. NOTICE
2. Simultaneously, press the OPEN and RESET If the dual-gate communication stops for
buttons to enter the Installer Menu. Release whatever reason, (communication wire severed
the buttons and the LEARN LIMITS display or the power switch is turned off in one unit),
appears which is the first item in the Installer both operators cease to function and an
Menu. ERROR 4 (Primary/Secondary Communication
Error) appears in the display.
3. Press NEXT until the DUAL GATE display
appears. The factory default setting is 0. 1. Start at a gate
status display.
4. Use the SELECT and NEXT buttons to navigate HYSECURITY
and change the setting to 2 PRIMARY. GATE CLOSED
5. To exit the Installer Menu, press the MENU OPEN CLOSE STOP MENU RESET
1. 4. Use NEXT to
navigate to the
When the SlideSmart operator has been DG 2 (MASTER) menu display.
designated as the primary and the other as DUAL GATE Change the
secondary, the dual-gate operators will be in setting using the
SELECT and
constant communication, most often, in a peer- OPEN CLOSE STOP MENU RESET NEXT buttons.
to-peer relationship. For example,
PREV NEXT SELECT
• Any control input that is attached to the
secondary unit will be recognized by the primary Figure 65. Primary-Secondary Menu Setup
USER2
• Troubleshoot error codes, faults, and hardware EMERG
OPEN COM OPEN +24V
S1
NS COM
NO
RADIO OPTIO
issues
A B
COM
SHOW DUAL GATE
LEDs
Shows connecons
• Diagnose vehicle detector and loop faults for Remote Open
and Gate Edge.
• Handle General Maintenance issues
CONNECTING A RADIO RECEIVER FOR
REMOTE OPEN
R1
Take the following steps to mount a commercial
style 24VDC radio receiver (external antenna type):
Power
1. Install the receiver in the channel of the chassis
on either side of the control box.
2. Route the wires to the area marked RADIO Two Channel Radio Receiver
OPTIONS. Only three wire connections are Figure 66. Radio Receiver Connections
needed because the common wire and one
radio output wire are connected together. INSTALLING A MAGLOCK OR SOLENOID
Figure 65 shows additional wires from a two LOCK
channel receiver.
To provide additional gate security, a maglock or
3. Make sure to observe polarity and crimp a solenoid lock can be used and connected to
together the black radio common wire and the Smart DC Controller. The Smart DC Controller
one of the radio output wires using a ¼-inch releases the lock prior to initiating gate movement.
spade connector. Before installing the lock, be sure to:
4. Fasten the two crimped wires to the COM • Determine the electrical power requirements of
terminal. your lock (maglock or solenoid lock). Electronic
5. Connect the red wire to the +24V spade and board and peripheral connections differ
connect the other radio output contact wire to between high voltage and lower voltage gate
the spade marked OPEN. operators.
• Determine the current required. Up to 1A is
NOTICE available from the 24VDC, or 12VDC power
This terminal is the same as the input terminal supply. If the peripherals attached to the
labeled RADIO OPEN along the left edge of terminals need more than 1A, a separate power
the Smart DC Controller. supply is required. Refer to "Overview Of The
Smart DC Controller" on page 73and Figure
57.
88 support.hysecurity.com
ACCESSORY CONNECTIONS
INSTALLING A LOCK FOR 12VDC OR INSTALLING A LOCK FOR HIGH VOLTAGE
24VDC SYSTEMS SYSTEMS
To install a high voltage lock for 12VDC or 24VDC To install a lock on higher voltage systems (115V
systems, take the following steps: or 230V), take the following steps:
1. Connect a wire between COM on USER 1 1. Connect one lead of the power supply to one
RELAY and a COM terminal on the Smart DC lead of the lock’s coil. See Figure 67.
Controller board. See Figure 66.
115VAC
COM 24VDC
24VDC
230VAC 1
COM
COM POWER SUPPLY
COM
COM 12VDC High voltage Lock
COM 12VDC
2
2
COM
COM Aach the power wire from the lock
High voltage
to the appropriate power spade.
STOP
OPEN
CLOSE 3 NO
RADIO
OPEN
OPEN
PARTIAL
SENSOR
2 COM
SENSOR
3
EXIT
LOOP
BLOCK
EXIT USER 1 RELAY
IN OBS
LOOP
OUTOBS USER 1 RELAY
LOOP
CENTER
LOOP Figure 68. Lock Installation- High Voltage
SENSOR
3
COM
NO NC 3
SENSOR Connect COM on board
COM to COM on USER 1 RELAY. 1 2. Connect the other lead of the lock’s coil to NO
+24V DC
on USER 1 RELAY.
USER2
90 support.hysecurity.com
ACCESSORY CONNECTIONS
5. Loop and lead-in wire should be one continuous • After the wire is installed, the slot must be
piece. Avoid splices, if possible. If a splice is completely backfilled with a non-hardening
necessary for any reason, “pot” the splice in sealer. If the loop wires are able to move in the
epoxy or use heat shrink to ensure that the slot after the sealer has set, the detector may
quality of the splice covering is the same as give false calls.
the original wire jacket.
6. Use only 14, 16, or 18 gauge stranded wire with
a direct burial jacket. Cross linked polyethylene
insulation types, such as, XLPE or XHHW, will
last much longer and are less prone to damage
during installation than conventional insulation
types. Preformed loops can be used before
road surfacing or under pavers.
7. Twist loose tails of lead-in wires tightly,
approximately ten times per foot. See Figure
69.
8. Follow this guide for the correct number of
Figure 71. Loop Sealant
turns in the loop; 12 to 20 sq. ft = 5 turns; 20
to 60 sq. ft. = 4 turns; 60 to 240 sq. ft. = 3 turns; Detector Logic
3.7 to 6.1sq. m = 5 turns; 6.1 to 18.3 sq. m = 4
HySecurity recommends that vehicle detectors
turns; 18.3 to 73.1sq. m = 3 turns
be used for free open and obstruction sensing
logic only. Because of their slower speeds, closing
Twist lead-in at least
10 turns per foot logic is a poor choice for security gate systems.
Twist Like This
Since there are several ways that the gate may
be left standing open and because there is a loss
Like This Not Like This
his of safety, our circuit has not been designed to
accommodate “detect to close” logic.
Loop Diagnostics
Figure 70. Wire Twist Lead-ins
The following tests cannot guarantee a functioning
9. This guide is written from a design perspective, loop, but failure of either test means that the loop
but installation workmanship practices are is definitely suspect, even though it may still be
equally important to insure proper operation functioning at the time.
and long loop life. The best way to insure a
quality installation is to employ a professional 1. Test the resistance of the loop and lead-in wire.
installer experienced with detector loops. A It should not exceed 4 Ohms.
few important practices are:
2. Test the resistance between the loop and
• The slot in the surface of the road should be cut earth ground with a 500V Megohm meter. It
¼-inch wide x 1½-inch deep (6.3mm x 38.1mm). should be 100 Megohms or more. Loops may
• The corners of the cut must be at an angle or function at 100 Megohms or less but will not
core drilled to relieve stress on the wires. be reliable (e.g. when the ground is wet from
rainfall). Low resistance indicates broken or
moisture saturated insulation. This is common
if inappropriate wire insulation has been used.
A schematic for a slide gate loop layout is shown
in Figure 71.
PUBLIC SIDE
INSIDE
D OBSTRUCTION
LOOP
E
DIMENSIONS
A = 6 to 20 (2 to 6m)
B = 6 to 8 (2m to 243cm)
C = Maintain 4 (122cm)
D = Maintain 5 (152cm) between loop FREE EXIT
and edge of roadway. No vehicle can pass
through such a small area and escape detecon.
E = Located for convenience of use.
SECURE SIDE
Figure 72. Vehicle Detectors and Loop Layouts for Slide Gates
92 support.hysecurity.com
ACCESSORY CONNECTIONS
MONITORED EXTERNAL ENTRAPMENT Three programmable sensor inputs are available
SENSORS for use and must be programmed to a non-zero
number when initial configuration is performed.
As of January 2016, UL325 standard requires gate The three inputs are labeled Sensor 1, Sensor 2,
operators to monitor the presence of all external and Sensor 3 and are configurable in the installer
entrapment sensors, including non-contact (Photo menu (S1, S2, or S3) for the following options:
Eyes) and contact (Edge) sensors. For operators
built between January 1st, 2016 and July 31st, • 1 − Not Used
2018 only one external entrapment sensor is • 2 − Eye Close
needed to allow automatic operation, but all • 3 − Edge Close
potential entrapment zones must be protected
• 4 − Eye Open
or eliminated. After July 31st, 2018, all Slide gate
operators will need a minimum of 2 external • 5 − Edge Open
entrapment sensors (1 open direction and 1 close • 6 − Edge Both (Swing Only)
direction) installed before automatic operation is • 7 − Eye Both (Solo Slide Only)
allowed, but all potential entrapment zones must
It is the installer's responsibility to determine the
be protected or eliminated.
number of potential entrapment zones that exist
HySecurity monitors all external entrapment and program the Sensor inputs according to which
sensors connections by looking for NC contacts type of external entrapment sensor will be used
connected to input terminals. Smart touch to protect each zone. If more than three potential
software cycles power to device and looks for entrapment zones exist, then site design may be
a time delay from when device powers on to adjusted to eliminate risks or a Miller Edge MIM-
when the contact closes (sensor input pulled low, 62 may be used to connect additional sensors.
meaning the sensor is not blocked/tripped).
Potential entrapment zones on a slide gate are
shown in Figure 72 Included in the drawing are
examples of potential external entrapment sensor
mounting/installation locations.
1 Draw-in Zone
Secure Side
Gate edge (protecting open direction)
(EDGE OPEN)
Public Side
Photo
Eye
2
Leading End
te
d Ga
Han
Le ing
n
ope
Photo
Eyes
All external entrapment protection sensors must be NC sensor Connect all contact and non-contact sensors to same
outputs and wired to the Sensor Com terminal for monitoring power source. Example, Do NOT connect photo eyes
and powering purposes. The sensor is actively powered until to +24VDC and gate edges to +12VDC. Incompatible
the gate reaches the open limit where the monitored check is power connections result in a FAULT 2 in the display.
performed.
NOTICE EMX IRB MON OLDER GREEN RX PCB EMX IRB MON
DIP switches must be Photo Eye Receiver Photo Eye Transmitter
For GREEN PCBs
set as shown, otherwise RECEIVER
(before 06/2020),
TRANSMITTER
1 234
from the newer red PCBs. ON
3 = ON
ON
2 = OFF
2 = OFF 3 = OFF
1 = OFF 4 = ON
If you receive an Alert, "!ACTION BLOCKED" "Photo Eye Open" PEO or "Photo Eye Close" PEC, take steps to align the photo eye.
SENSOR 1,2, or 3
SENSOR COM
94 support.hysecurity.com
ACCESSORY CONNECTIONS
EXTERNAL ENTRAPMENT PROTECTION the gate as possible. A minimum of one photo
eyes is required, but two is recommended,
Consult a photoelectric sensor manual for wiring one photo eye to guard the open direction
details. Make all electrical connections to Smart and the other for the close direction of travel,
DC Controller as shown in Figure 75. unless gate edges for entrapment protection
PARTIAL are installed.
SENSOR 2 SENSOR2
z Three wires to the receiver and two wires to the
SENSOR3
SENSOR 3 emitter are all that is required.
EXIT
LOOP • Depending on how the photo eyes are to be
BLOCK wired, +24VDC or +12VDC, power is provided
EXIT
IN OBS via spades located just to the right of the COM
LOOP terminal strip near the left side of the board,
OUTOBS
LOOP but wire all eyes to 24V or all to 12V, do not
CENTER
LOOP
mix voltages.
SENSOR 1 SENSOR1 • The receiver and emitter common wires are
SENSOR COM SENSOR connected to the SENSOR COM terminal at
Terminal COM
the bottom, left of the Smart DC Controller.
Photo Eye +24 +24V
VDC EMERG • The photo eye NO or NC output wires connect
OPEN EN
EDGE +24V OP ONS
to the Smart DC Controller at the appropriate
SHOW RADIO OPTI Sensor Input (1, 2, or 3). The appropriate sensor
LEDs
input must be programmed for Eye Open or
Eye Close based on whether it spans the road
or the "catch" area of an opening gate.
Figure 76. Entrapment Protection Only Connections
z If tripped while in motion, the standard function
PHOTO EYE INSTALLATION TIPS is to stop the gate and automatically restart again
if the photo eye is clear within five seconds. An
Underwriters Laboratories requires that any non- optional setting in the Installer Menu will cause
contact sensor used as an external entrapment a two second reversal of travel, or, if closing, can
protection device, must be tested to, and be programmed to reverse to full open.
recognized by, the UL 325 Standard.
NOTICE
z There are two common types of photoelectric
sensors, thru-beam and retro-reflective, and Sensor Common & +24V is the recommended
each has its advantages. way to connect monitored photo eyes to Smart
DC Controller.
• A thru-beam sensor is generally more
powerful and able to function reliably with dirty NOTICE
optics and in poor weather.
• A retro-reflective sensor does not require If photo eyes are to be used for vehicle
the installation and extra wiring of a separate detection and logically function the same as
emitter and receiver as is required in a thru- a vehicle detector, connect the common wires
beam system, but retro-reflective eyes are to the COM terminals on the left side of the
generally more problematic in poor weather. board and wire the NO output contact to the
Avoid using retro-reflective devices across appropriate vehicle detector input: EXIT LOOP,
outdoor distances greater than 24 ft (7.3m) IN OBS LOOP, and OUT OBS LOOP.
because of performance and reliability issues.
• For pedestrian detection, mount thru-beam
type photo eyes approximately 15" to 27" (38
to 68.5 cm) above the ground and as close to
96 support.hysecurity.com
ACCESSORY CONNECTIONS
PUBLIC SIDE
A
Placement of photo eyes for entrapment protecon
INSIDE OBSTRUCTION
2 Placement of
photo eyes
if used as
vehicle detectors.
FREE EXIT
3 Placement of
photo eyes
if used as
DIMENSIONS
vehicle detectors.
A = width of roadway*
*Reflecve photo eyes can only
be used if “A” is less than 24 (7.3m)
SECURE SIDE
98 support.hysecurity.com
TROUBLESHOOTING
SMART DC CONTROLLER TROUBLESHOOTING
This section is available to help you troubleshoot any problems that may occur with SlideSmart operator.
It provides information about Smart DC Controller display codes.
The Smart DC Controller system includes many self diagnostics. Specific messages appear on LCD and
Audio Alert buzzer sounds distinctive chirps. Any alerts, faults or errors are also logged into memory
and date/time stamped. For diagnostic purposes these messages can be retrieved with optional START
software available from HySecurity. Refer to "Smart Touch Analyze and Retrieve Tool" on page 114.
The following Table 16 provides solutions to error codes, faults, and alerts that may appear on Smart
DC Controller display.
100 support.hysecurity.com
TROUBLESHOOTING
Table 16. Smart DC Controller - Troubleshooting
Description
Display
Alert, Error or Possible Causes Solutions
Condition
Fault
1. No AC Power. See
above item.
2. Wiring / Connector
problem - check
all connections.
Occurs when battery voltage has
Clean or repair as
dropped to less than 21V. At this
Extremely low required.
level, batteries are 90% depleted.
UPS batteries
Gate will automatically open or close 3. Check battery
– no automatic
DEAD BATTERY depending upon setting chosen. Refer condition.
operation -
to AP - AC LOSS under "User Menu"
batteries below 4. Smart DC Controller
on page 48. No additional automatic
21V. charger failure
function is possible, but limited push
- check charger
button control is available to 18V.
voltage and
replace Smart DC
Controller.
5. Transformer failure -
replace Transformer.
1. No AC Power. See
above item.
2. Wiring / Connector
Critically low 24V problem - check
supply power. all connections.
This message Clean or repair as
HYSECURITY DC power is below 14V – no control
can occur only required.
BAD POWER functions will be allowed at all.
on initial start
3. Check battery
up if power is
condition. check
critically low.
power board power
switch for 115V or
230V and match to
incoming power.
102 support.hysecurity.com
TROUBLESHOOTING
Table 16. Smart DC Controller - Troubleshooting
Description
Display
Alert, Error or Possible Causes Solutions
Condition
Fault
Hy5B has Loop lead in wires and
ALERT 8 d e t e c t e d a Caused by inadequate insulation of ro a d w a y s h o u l d b e
LOOP SHORTED loop shorted to loop wires. checked for problems
ground. or replaced.
Hy5B has
Loop and lead in wires
ALERT 9 detected a lack Caused by broken loop wire or wire
should be checked for
LOOP OPEN of continuity in has come unplugged from detector.
problems or replaced.
loop wire.
Smart DC Caused by removal of Hy5B or lack
Controller has of integrity of socket connection.
Remove and re-install
detected a This message will also indicate which
ALERT 10 the Hy5B and press
communication detector alert applies to: Exit Loop
12C BUS ERROR RESET. Replace Hy5B, if
error with a (ELD), Inside Obstruction Loop (IOLD),
necessary.
Hy5B vehicle Outside Obstruction Loop (OOLD), or
detector. Center Loop (CLD).
Smart D C Caused by a fault within Hy5B. This
Controller has message will also indicate which Remove and re-install
ALERT 11
d e t e c t e d a detector alert applies to: Exit Loop the Hy5A and press
DETECTOR
problem within (ELD), Inside Obstruction Loop (IOLD), RESET. Replace Hy5B, if
FAULT
an Hy5B vehicle Outside Obstruction Loop (OOLD), or necessary.
detector. Center Loop (CLD).
Caused when Smart DC Controller
Smart DC sees an active loop for more than
Controller has 5 minutes. “Active” loop can be Check traffic patterns
an active loop actual or false. This message will at site. Loop and lead
ALERT 12
input (Hy5B or also indicate which detector alert in wires should be
ON TOO LONG
box detector applies to: Exit Loop (ELD), Inside checked for problems
output) for more Obstruction Loop (IOLD), Outside or replaced.
than 5 minutes. Obstruction Loop (OOLD), or Center
Loop (CLD).
Smart DC
Caused by degrading gate hardware
Controller has
or debris in track. This alert appears in
detected a gate
ALERT 13 history log. It does not have any effect Check and correct gate
that, over time,
STIFF GATE with regard to opening or closing hardware as required.
has taken more
gate. Caused when motor current is
power to move
too high.
than it used to.
104 support.hysecurity.com
TROUBLESHOOTING
Table 16. Smart DC Controller - Troubleshooting
Description
Display
Alert, Error or Possible Causes Solutions
Condition
Fault
FAULT 1 Should not
MOTOR RUN occur in Maximum run timer fault. Call Technical Support.
TIME SlideSmart.
Not used in
ALERT 21
SlideSmart.
1. Check cable
connections and
wiring. Make sure
both operators are
working properly
and have same
current and up-
to-date software
versions. Alert
auto clears when
communication
Interlock/ Appears when RS-485 communication between two
ALERT 22
Sequential Gate connection is lost for more than 5s operators is
INTLOCK
communication between interlocked (dual gate) or restored.
FAILURE
lost sequenced gate operators.
2. If operator on
site is a solo gate
operator and
display code ALERT
22 appears, access
Installer Menu.
Verify Installer
Menu items: DG
(Dual Gate) and SG
(Sequential Gate)
are both set to zero.
If no module is used,
reset R3-R10 to 0. If a
module is used, ensure
Communication Appears when R3-R10 is programmed
ALERT 24 - that all wiring is correct
Lost with to a non-zero number in the installer
EXTERNAL and the correct module
Hy8Relay menu, but there is no Hy8Relay module
RELAY FAULT is being used. The STC
module communicating with the board.
and SDC communicate
at different rates with
the module.
106 support.hysecurity.com
TROUBLESHOOTING
Table 16. Smart DC Controller - Troubleshooting
Description
Display
Alert, Error or Possible Causes Solutions
Condition
Fault
Smart DC
Caused by Hy5B removal or lacks 1. Press RESET.
Controller
socket connection integrity. Message
detects 2. Remove and re-
ERROR 3 indicates which detector alert applies
communication install Hy5B.
Hy5B FAILED to: Exit Loop (ELD), Inside Obstruction
error with a
Loop (IOLD), Outside Obstruction 3. Replace Hy5B, if
Hy5B vehicle
Loop (OOLD), or Center Loop (CLD). needed.
detector.
1. Correct
communication
cable.
2. Verify each operator
is configured
properly via Installer
Several possible causes: Menu. Set one
• Primary/Secondary communication operator as Primary,
cable has not been installed correctly. one as Secondary.
See Primary and Secondary Wiring 3. Install ground rod
Smart DC Connections. per NEC/NFPA
Controller has • Primary/Secondary not configured standard.
detected a properly through Installer Menu.
ERROR 4 4. Install separate
communication
PRIMARY- • Operator not properly Operator not communication
error between
SECONDARY properly earth grounded. cables conduit.
primary and
COMM • Primary/Secondary communication 5. Ensure AC power
secondary in
a dual gate cable installed in same conduit as is present at both
installation. high-voltage AC power. operators and all
• One operator does not have power power switches are
applied to it. ON.
• One operator may have a different 6. Check software
software version. version currently
loaded in operator
by pressing RESET.
Make sure both
operators are
running same
software version.
108 support.hysecurity.com
TROUBLESHOOTING
VEHICLE DETECTOR AND LOOP FAULT DIAGNOSTICS
If HySecurity Hy5B vehicle detector modules are used, the Smart DC Controller has the ability to store
and report detector and loop fault information for performance diagnostics.
If the Smart DC Controller senses a loop or detector problem:
z The LCD display flashes the name of the affected detector or error and the appropriate alert code.
z The buzzer chirps continuously at regular intervals until the issue is resolved.
Table 17. Hy5B Vehicle Detector Faults and Errors
Alert or LCD
Advisory Resolution
Error # Description
Hy5B vehicle detector
Alert indicates an unstable loop frequency. Check
FREQ SHIFT
ALERT 7 - Abnormal frequency
loop and lead in wires for problems. Replace
FAULT
change alert. them, if necessary.
Alert indicates that loop and lead in wires are
LOOP Hy5B vehicle detector -
ALERT 8 shorting out. Check wires for problems. Replace
SHORTENED Loop is shorted.
them, if necessary.
Alert indicates loop wires are loose or
Hy5B vehicle detector -
ALERT 9 LOOP OPEN disconnected. Check wires for problems. Replace
Disconnected loop alert.
them, if necessary.
Alert indicates detector is not communicating
properly with Smart DC Controller. Alert occurs if
ALERT I2C BUS Hy5B vehicle detector - detector is unplugged or connection is unstable.
10 ERROR Communications alert. If communication is not reestablished within
30 seconds, controller will reset and message
changes to ERROR 3.
Display indicates Hy5B detector malfunction.
ALERT DETECTOR Hy5B vehicle detector -
Check detector for problems. Replace it, if
11 FAULT Malfunction alert.
necessary.
Display indicates Hy5B detector malfunction.
It alert also works for any input connected to
Detector input triggered
ALERT ON TOO terminal strip for standard box detectors. Check
too long - More than five
12 LONG that a vehicle is not parked on loop. Also,
minutes.
determine if loop is stable. An unstable loop can
hold detector in a triggered state.
Hy5B vehicle detector -
Alert indicates detector is not communicating
Communication failed.
properly with Smart DC Controller. Alert occurs
DETECTOR Smart DC Controller will
ERROR 3 if detector is unplugged or detector has failed.
FAILED behave as if detector is
To replace detector, press RESET button to clear
triggered, usually holding
error and re-seat detector or install a new one.
gate fully open.
110 support.hysecurity.com
TROUBLESHOOTING
Frequency: Table 19. Hy5B Vehicle Detector Call Level
Knowing the exact frequency of a loop can Display
be useful as a diagnostic tool, and verifying Setting
the stability of the loop frequency is valuable Options
information. To view the actual loop frequency Installer
LCD Description (Bold =
of a specific vehicle detector, go to the setting Menu
for that detector in the Installer Menu, switch Factory
the selection from 0 to 1, and press the Select Settings)
button. The display will show the loop frequency. ELD 0 EXIT LOOP SET 0 = Run mode
The frequency is usually between 20,000 to 80,000 ILD 0 IN OBS LOOP SET 1 = Show
Hertz.
OUT OBS LOOP frequency
Changing the Loop Frequency: OLD 0
SET
2 = Show call
Hy5B detectors can never crosstalk. If for any level 0-7
reason, you want to manually change the loop
frequency, change the Installer Menu option 3 = Set
for the desired loop from 0 to 3, and then press Frequency
the Select button. Each detector has a choice of 4 = Show
four frequencies. Press the Select button when Sensitivity
the desired frequency setting is found, and the CENTER LOOP SET
controller will perform a reset and tune to the new 5 = Set
CLD 0 (Can be used as an Sensitivity
frequency setting. arming loop with
Call Strength Level: User Relay 22.) 6 = Show
Inductance
Knowing the call strength of a detector is valuable
because it provides information about how well 7 = Show Loop
the loop is actually “seeing” a specific vehicle. Health
For example, it may be useful to check to see if 8 = Set
the loop is easily detecting the middle of a high Presence
bed semi-truck. The strength of a detector call
can be displayed in real time, on a scale of 0 to 7.
As indicated in the table below, when the Installer
Menu setting for a given detector is set to 2, and
the Menu button is pressed, the LCD display will
read Level 0 - 7 Call Level. If the call strength on
the display appears as a level 4 or less, consider
increasing the sensitivity level by adjusting the
rotary switch on the Hy5B detector.
112 support.hysecurity.com
SCHEMATICS
Read the START User Manual, and then take the PEN COM
B COM A
GATE
COM NO
EDGE +24V O ONS UAL
D
following steps to download START software: RADIO OPTI
USB PORT RS-485
1. Bring up your web browser and type in http:// COMMUNICATION
www.hysecurity.com in the command line.
2. Click Technical Support (left column) on the Figure 81. Smart DC Controller RS-232 and USB
HySecurity home page. Connection
114 support.hysecurity.com
MAINTENANCE
SETTING USER ACCOUNT CONTROLS MECHANICAL MAINTENANCE
Because of the security settings inherent in VISTA CAUTION
and Windows 7, you may need to disable the “user
account controls” in the operating system before Before checking internal mechanisms of
uploading START software onto your laptop. Take operator, turn off all power switches.
the following steps:
SlideSmart mechanical maintenance is not in
In Windows 7: depth or difficult, but should be performed on a
Go to Start Menu -> Control Panel -> User routine basis. Operator chassis is zinc plated, but
Accounts and Family Safety -> User Account -> some environments may speed corrosion of this
Change User Account Control Settings “slide the plating.
slide bar to the lowest value (toward Never Notify), Schedule regular maintenance and look for the
with description showing Never notify me -> Press following:
Ok -> Reboot Computer.
• Verify drive belt has proper tension. Check for
In Vista: drive belt wear. Fraying edges or missing teeth
Go to the Start Menu type “msconfig” and press indicate that drive belt needs to be replaced.
Enter -> In System Configuration select the tools Refer to "Drive Belt Tension And Alignment"
tab -> Scroll down till you find "Disable UAC" on page 116.
and single click it -> Press the Launch button -> • Check for signs of rust. If any areas of rust are
Press the Apply button -> Press OK -> Reboot found, reduce spread of corrosion by treating
Computer. areas with a rust inhibitor.
ELECTRICAL CONTROLS • Check motor. DC motors contain carbon brushes
which wear over time and must be replaced.
CAUTION Failure to replace brushes will result in DC motor
damage. Brushes should be inspected every
Before servicing, turn OFF all power switches. year in high usage applications or every 100,000
cycles and replaced as needed.
No routine maintenance is needed for the • Replace worn-out batteries. Refer to "DC
electrical system or controls. If the environment is Battery Replacement" on page 117 and "Clock
very sandy or dusty, or has many insects, be certain Battery Replacement" on page 118.
to seal all holes in the electrical enclosure. Blow
the dust out of the electric panel with compressed SOFTWARE MAINTENANCE
air. Use "Smart DC Controller Troubleshooting"
SDC board software is constantly being enhanced
on page 99 to assess and fix error, alert, and
with new features that create an easier install and
fault codes. If it is necessary to call a distributor
improve on board diagnostic tools. Check the
for assistance, be sure to have your model and
HySecurity website for atest version of software
serial number ready. Other helpful information
before heading out for field maintenance.
includes the name of the job, approximate date of
installation, and the service record of the operator. Use S.T.A.R.T. software to download latest software
version to a PC laptop and upload it to SlideSmart
gate operator in the field.
NOTICE
If the site includes a bi-parting gate system,
make sure the software version used in the
Master and Slave operators is identical.
116 support.hysecurity.com
MAINTENANCE
DC BATTERY REPLACEMENT 2. To access the 8Ah batteries and disconnect its
wires, cut the two black wire ties and slide the
HySecurity provides a one year warranty from the 8Ah batteries through the access window. See
date of shipment for all batteries supplied with Figure 83. Another option is to remove the four
the SlideSmart operator. screws that hold the control box to the chassis.
Indicators of a low battery include: 3. Disconnect the black, blue, and red wires as
• LOW BATTERY or DEAD BATTERY appears on you slide the batteries through the access
the Smart DC Controller display which may or window. See Figure 83.
may not be indicative of normal discharge.
• ALERT 18 CHANGE BATTERY appears on the
Smart DC Controller display. The operator
emits an audible chirp every minute to indicate
DISCONNECT
a problem exists. WIRES
NOTICE
For detailed information about the AP AC Figure 84. DC Battery Replacement
LOSS configuration, refer to Setting AC Power
To install the two new batteries, reverse the
Loss Gate Function.
removal procedure. See Figure 84.
Symptoms of a low battery may include: 1. Connect the red wire to the red terminal on the
• Gate remains locked in the open position left battery and slide the battery onto the tray.
• Gate remains locked in the closed position 2. Attach the blue wire to the black terminal.
• Gate opens five seconds after AC power loss 3. Insert the second 8Ah battery and connect the
and locks open blue wire to the red terminal).
CAUTION 4. As you slide the battery onto the tray, connect
Before replacing the batteries, turn off all the black wire to the black terminal on the
power switches. Use only AGM batteries right battery.
as replacements (8Ah - MX002008, 50Ah -
MX002013). The batteries supplied in the
SlideSmart operator are state-of-the-art AGM
batteries. Do NOT use flooded cell batteries as
damage may occur to the unit. Wear protective RED
clothing while working with batteries.
BLACK
WIRE WIRE
The two 8Ah batteries are accessible within the WIRE BLUE
operator on a tray behind the control box. TIES WIRES
RIGHT
BATTERY
Slide cover
Four Phillips-head off the
screws secure control box Cut
the control to access wire ties
box to the the screws.
chassis.
USER 1
Lithium
baery
DC
USER2
B COM A COM NO
DUAL GATE
118 support.hysecurity.com
APPENDIX A - INSTALLATION CONFIGURATIONS
This appendix contains drawings of the various installation configurations for the SlideSmart operator.
Provided in this appendix are drawing specifications for:
• Concrete pad layout and dimensions
• Conduit and ground
• Base extension
• Post mounted
• Post mounted with base extension
• Rear mounted installation
3.25 Gate
2.50 Chain, #40 Roller
Chain to Gate
5.50
2.66
1.63
Chain
7.75
Chain Height
Ground level
Conduits stubbed
Pad 2"
minimum 2" above pad to
above ground.
a maximum of 4"
120 support.hysecurity.com
APPENDIX A - INSTALLATION CONFIGURATIONS
Gate
3.25
2.50 Chain
Chain to Gate
20.0
Operator
18.0 Length
20.7
Operator
Height
Earth Ground
High Voltage
Master/Slave Wires
(Optional)
Vehicle Loop
Consult local
codes for Control Wires
proper depth
Low Voltage /
3 Foot
Communication Wires
Maximum
3.25
2.50 Gate
Chain to Gate Chain
If no batteries In Base Riser -
Conduit Area is 8.5"x12"
5.50
2.66
12.5
10.50
17.5
6x8.5
Conduit
Area
4X 1/2" x 3 1/2"
Concrete Anchors
10.38
3.25
2.50
18.0 CHAIN TO GATE
7.75
Optional 50Ah
Batteries
20.3
12.5
.72
122 support.hysecurity.com
APPENDIX A - INSTALLATION CONFIGURATIONS
3.25
2.50 Gate Chain
Chain to Gate
2.66
10.50 6.75 x 9
Conduit 17.5
Area
U-bolts provided for 4" OD pipe (slot allows for
3.5-4.5" OD pipe. For best results,
5.00 4.00 HySecurity recommends welding plate to posts.
4X .625
3.25
5.50 2.50
Chain to Gate
3.81 10.38
18.0
20.7
7.75
Chain Height
3.0
Post
Height
.72
6.0
17.63 ID of
Post Mount Plate
2.66
If no batteries In Base Riser -
Conduit Area is 7"x9"
10.50
17.5
4.5 x 7
Conduit U-bolts provided for 4" OD pipe (slot allows for
Area
3.5-4.5" OD pipe). For best results,
5.00 4.00 HySecurity recommends welding plate to posts.
4X .625
3.25
2.50
5.50
Chain to Gate
3.81 10.38
18.0
20.7
7.75
12.5
3.0
Post
Height
.72
6.0
17.63 ID of
Post Mount Plate
NOTE: DRAWING IS NOT TO SCALE.
124 support.hysecurity.com
APPENDIX A - INSTALLATION CONFIGURATIONS
4.75
8.0
3.25 7.75
126 support.hysecurity.com
APPENDIX A - INSTALLATION CONFIGURATIONS
128 support.hysecurity.com
APPENDIX B - FRENCH TRANSLATIONS
FRENCH TRANSLATIONS
The following French translations provided below are found in the Safety Section located at the beginning
of the manual.
English French
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
IMPORTANT SAFETY INSTRUCTIONS
AVERTISSEMENT – Pour réduire les risques de
WARNING – To reduce the risk of injury or death:
blessures et de mort :
1. LISEZ CETTE NOTICE ET CONFORMEZ-
1. READ AND FOLLOW ALL INSTRUCTIONS.
VOUS AUX MISES EN GARDE
2. Ne laissez jamais les enfants manoeuvrer les
2. Never let children operate or play with gate
commandes de la barrière ou jouer avec celles-
controls. Keep the remote control away from
ci. Laissez la télécommande hors de la portée
children.
des enfants.
3. Tenez toujours à l’écart de la barrière toute
3. Always keep people and objects away from
personne ou tout objet avoisinant. IL NE FAUT
the gate. NO ONE SHOULD CROSS THE PATH
JAMAIS PASSER DANS LA TRAJECTOIRE
OF THE MOVING GATE.
D’UNE BARRIÈRE EN MOUVEMENT.
4. Vérifiez le fonctionnement de l’ouvre-barrière
une fois par mois. Le sens de la course DOIT
4. Test the gate operator monthly. The gate s’inverser lorsque la barrière entre en contact
MUST reverse on contact with a rigid object or avec un objet dur ou la barrière DOIT s’arrêter
stop when an object activates the non-contact lorsqu’un objet active les capteurs sans contact.
sensors. After adjusting the force or the limit Vérifiez à nouveau l’ouvre-barrière après tout
of travel, retest the gate operator. Failure to réglage de la force de déclenchement ou du
adjust and retest the gate operator properly can seuil de fin de course. Un réglage incorrect
increase the risk of injury or death. de l’ouvre-barrière ou l’omission de vérifier à
nouveau le fonctionnement de l’ouvre-barrière
peut causer des blessures, voire la mort.
5. Ne déclenchez le dispositif de
5. Use the emergency release only when the gate
désaccouplement d’urgence que lorsque la
is not moving.
barrière ne bouge pas.
6. ASSUREZ-VOUS QUE LA BARRIÈRE EST
6. KEEP GATES PROPERLY MAINTAINED. Read
CORRECTEMENT ENTRETENUE. Lisez le
the user’s manual. Have a qualified service
manuel de l’utilisateur. Confiez la réparation du
person make repairs to gate hardware.
matériel de la barrière à un technicien qualifié.
7. La voie d’accès est réservée aux véhicules
7. The entrance is for vehicles only. Pedestrians
seulement. Les piétons doivent utiliser une voie
must use separate entrance.
d’accès différente.
8. SAVE THESE INSTRUCTIONS. 8. CONSERVEZ CES INSTRUCTIONS.
English French
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
IMPORTANT SAFETY INSTRUCTIONS
AVERTISSEMENT – Pour réduire les risques de
WARNING – To reduce the risk of injury or death:
blessures et de mort :
1. LISEZ CETTE NOTICE ET CONFORMEZ-
1. READ AND FOLLOW ALL INSTRUCTIONS.
VOUS AUX MISES EN GARDE
2. Ne laissez jamais les enfants manoeuvrer les
2. Never let children operate or play with gate
commandes de la barrière ou jouer avec celles-
controls. Keep the remote control away from
ci. Laissez la télécommande hors de la portée
children.
des enfants.
3. Tenez toujours à l’écart de la barrière toute
3. Always keep people and objects away from
personne ou tout objet avoisinant. IL NE FAUT
the gate. NO ONE SHOULD CROSS THE PATH
JAMAIS PASSER DANS LA TRAJECTOIRE
OF THE MOVING GATE.
D’UNE BARRIÈRE EN MOUVEMENT.
4. Vérifiez le fonctionnement de l’ouvre-barrière
une fois par mois. Le sens de la course DOIT
4. Test the gate operator monthly. The gate s’inverser lorsque la barrière entre en contact
MUST reverse on contact with a rigid object or avec un objet dur ou la barrière DOIT s’arrêter
stop when an object activates the non-contact lorsqu’un objet active les capteurs sans contact.
sensors. After adjusting the force or the limit Vérifiez à nouveau l’ouvre-barrière après tout
of travel, retest the gate operator. Failure to réglage de la force de déclenchement ou du
adjust and retest the gate operator properly can seuil de fin de course. Un réglage incorrect
increase the risk of injury or death. de l’ouvre-barrière ou l’omission de vérifier à
nouveau le fonctionnement de l’ouvre-barrière
peut causer des blessures, voire la mort.
5. Ne déclenchez le dispositif de
5. Use the emergency release only when the gate
désaccouplement d’urgence que lorsque la
is not moving.
barrière ne bouge pas.
6. ASSUREZ-VOUS QUE LA BARRIÈRE EST
6. KEEP GATES PROPERLY MAINTAINED. Read
CORRECTEMENT ENTRETENUE. Lisez le
the user’s manual. Have a qualified service
manuel de l’utilisateur. Confiez la réparation du
person make repairs to gate hardware.
matériel de la barrière à un technicien qualifié.
7. La voie d’accès est réservée aux véhicules
7. The entrance is for vehicles only. Pedestrians
seulement. Les piétons doivent utiliser une voie
must use separate entrance.
d’accès différente.
8. SAVE THESE INSTRUCTIONS. 8. CONSERVEZ CES INSTRUCTIONS.
130 support.hysecurity.com
APPENDIX B - FRENCH TRANSLATIONS
FRENCH TRANSLATIONS
The following French translations provided below are found in the Safety Section located at the beginning
of the manual.
English French
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
IMPORTANT SAFETY INSTRUCTIONS
AVERTISSEMENT – Pour réduire les risques de
WARNING – To reduce the risk of injury or death:
blessures et de mort :
1. LISEZ CETTE NOTICE ET CONFORMEZ-
1. READ AND FOLLOW ALL INSTRUCTIONS.
VOUS AUX MISES EN GARDE
2. Ne laissez jamais les enfants manoeuvrer les
2. Never let children operate or play with gate
commandes de la barrière ou jouer avec celles-
controls. Keep the remote control away from
ci. Laissez la télécommande hors de la portée
children.
des enfants.
3. Tenez toujours à l’écart de la barrière toute
3. Always keep people and objects away from
personne ou tout objet avoisinant. IL NE FAUT
the gate. NO ONE SHOULD CROSS THE PATH
JAMAIS PASSER DANS LA TRAJECTOIRE
OF THE MOVING GATE.
D’UNE BARRIÈRE EN MOUVEMENT.
4. Vérifiez le fonctionnement de l’ouvre-barrière
une fois par mois. Le sens de la course DOIT
4. Test the gate operator monthly. The gate s’inverser lorsque la barrière entre en contact
MUST reverse on contact with a rigid object or avec un objet dur ou la barrière DOIT s’arrêter
stop when an object activates the non-contact lorsqu’un objet active les capteurs sans contact.
sensors. After adjusting the force or the limit Vérifiez à nouveau l’ouvre-barrière après tout
of travel, retest the gate operator. Failure to réglage de la force de déclenchement ou du
adjust and retest the gate operator properly can seuil de fin de course. Un réglage incorrect
increase the risk of injury or death. de l’ouvre-barrière ou l’omission de vérifier à
nouveau le fonctionnement de l’ouvre-barrière
peut causer des blessures, voire la mort.
5. Ne déclenchez le dispositif de
5. Use the emergency release only when the gate
désaccouplement d’urgence que lorsque la
is not moving.
barrière ne bouge pas.
6. ASSUREZ-VOUS QUE LA BARRIÈRE EST
6. KEEP GATES PROPERLY MAINTAINED. Read
CORRECTEMENT ENTRETENUE. Lisez le
the user’s manual. Have a qualified service
manuel de l’utilisateur. Confiez la réparation du
person make repairs to gate hardware.
matériel de la barrière à un technicien qualifié.
7. La voie d’accès est réservée aux véhicules
7. The entrance is for vehicles only. Pedestrians
seulement. Les piétons doivent utiliser une voie
must use separate entrance.
d’accès différente.
8. SAVE THESE INSTRUCTIONS. 8. CONSERVEZ CES INSTRUCTIONS.
English French
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
IMPORTANT SAFETY INSTRUCTIONS
AVERTISSEMENT – Pour réduire les risques de
WARNING – To reduce the risk of injury or death:
blessures et de mort :
1. LISEZ CETTE NOTICE ET CONFORMEZ-
1. READ AND FOLLOW ALL INSTRUCTIONS.
VOUS AUX MISES EN GARDE
2. Ne laissez jamais les enfants manoeuvrer les
2. Never let children operate or play with gate
commandes de la barrière ou jouer avec celles-
controls. Keep the remote control away from
ci. Laissez la télécommande hors de la portée
children.
des enfants.
3. Tenez toujours à l’écart de la barrière toute
3. Always keep people and objects away from
personne ou tout objet avoisinant. IL NE FAUT
the gate. NO ONE SHOULD CROSS THE PATH
JAMAIS PASSER DANS LA TRAJECTOIRE
OF THE MOVING GATE.
D’UNE BARRIÈRE EN MOUVEMENT.
4. Vérifiez le fonctionnement de l’ouvre-barrière
une fois par mois. Le sens de la course DOIT
4. Test the gate operator monthly. The gate s’inverser lorsque la barrière entre en contact
MUST reverse on contact with a rigid object or avec un objet dur ou la barrière DOIT s’arrêter
stop when an object activates the non-contact lorsqu’un objet active les capteurs sans contact.
sensors. After adjusting the force or the limit Vérifiez à nouveau l’ouvre-barrière après tout
of travel, retest the gate operator. Failure to réglage de la force de déclenchement ou du
adjust and retest the gate operator properly can seuil de fin de course. Un réglage incorrect
increase the risk of injury or death. de l’ouvre-barrière ou l’omission de vérifier à
nouveau le fonctionnement de l’ouvre-barrière
peut causer des blessures, voire la mort.
5. Ne déclenchez le dispositif de
5. Use the emergency release only when the gate
désaccouplement d’urgence que lorsque la
is not moving.
barrière ne bouge pas.
6. ASSUREZ-VOUS QUE LA BARRIÈRE EST
6. KEEP GATES PROPERLY MAINTAINED. Read
CORRECTEMENT ENTRETENUE. Lisez le
the user’s manual. Have a qualified service
manuel de l’utilisateur. Confiez la réparation du
person make repairs to gate hardware.
matériel de la barrière à un technicien qualifié.
7. La voie d’accès est réservée aux véhicules
7. The entrance is for vehicles only. Pedestrians
seulement. Les piétons doivent utiliser une voie
must use separate entrance.
d’accès différente.
8. SAVE THESE INSTRUCTIONS. 8. CONSERVEZ CES INSTRUCTIONS.
132 support.hysecurity.com
PARTS & LIMITED WARRANTY
SLIDESMART PARTS
Board, Smart DC Controller
Buzzer
Switch, On/Off
Detector, Vehicle
Circuit Breaker
Switch, On/Off
Cover, 2-Piece
Belt, Drive
Gearbox
Motor, Electric
Sprocket
Target, Magnet
Chain
Cover, 2-Piece
Battery Kit, 50 Ah
Base Extension
134 support.hysecurity.com
WARRANTY
6705 S 209th St, Ste 101
Kent, WA 98032
800-321-9947
WARRANTY www.hysecurity.com
1. Warranty. terrorism or war; or (3) damaged through improper opera�on, maintenance, storage
Hy-Security Gate, Inc. (“HySecurity”) warrants that at the �me of sale each or abnormal or extraordinary use or abuse. Any modifica�on made to products will
HySecurity-branded product that it sells will, in all material respects, conform to its void the warranty unless the modifica�ons are approved in wri�ng by HySecurity in
then applicable specifica�on and will be free from defects in material and advance of the change (this exclusion does not apply to normal installa�on of
manufacture. approved accessories and/or protec�ve devices or sensors). It is the responsibility of
The following addi�onal dura�onal warran�es apply to HySecurity products, the Distributor, Dealer/Installer, or End User to ensure that the so�ware version in
depending on whether (1) the product is purchased through an authorized the product is maintained to the latest revision level.
HySecurity distributor and (2) whether a �mely and complete product registra�on is The preceding warran�es do not extend to accessories when those items carry
submited to HySecurity. another manufacturer’s name plate and they are not a part of the base model.
It is therefore important that you register your product with HySecurity, online at HySecurity disclaims all warran�es for such accessory components, which carry only
www.hysecurity.com/warranty, within the 60-day period described below. the original warranty, if any, of their original manufacturer. HySecurity hereby assigns
1(a) HySecurity Products Purchased Through Authorized Distributors and Properly its rights under such manufacturer warran�es—to the extent that such rights are
Registered assignable—to Buyer.
For any gate operator product that is purchased from an authorized HySecurity These warran�es extend to HySecurity’s Distributors, to the Dealer/Installer, and
distributor (this excludes product purchased through internet resellers or any to the first End User of the product following installa�on. They do not extend to
distributor not authorized by HySecurity), if the product registra�on is completed by subsequent purchasers.
the Dealer/Installer or End User within 60 days of the date of purchase, the following 2. Exclusion of Other Warran�es.
warranty terms will apply. HySecurity warrants that the product will remain The warran�es contained in Sec�on 1 are the exclusive warran�es given by
serviceable for the following periods: HySecurity and supersede any prior, contrary or addi�onal representa�ons, whether
a) Hydraulic industrial gate operator hydraulics, controls, and mechanical oral or writen. Any prior or extrinsic representa�ons or agreements are discharged
components: Five Years or 500,000 gate cycles (whichever occurs first) a�er the or nullified. HYSECURITY HEREBY DISCLAIMS AND EXCLUDES ALL OTHER
date of installa�on, WARRANTIES—WHETHER EXPRESS, IMPLIED, OR STATUTORY—INCLUDING ANY
b) Hydraulic wedge operator hydraulics and controls: Five Years or 500,000 cycles WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A
(whichever occurs first) a�er the date of installa�on. Wedge mechanical PARTICULAR PURPOSE, ANY LIABILITY FOR INFRINGEMENT, AND ANY WARRANTIES
components: Two Years a�er the date of installa�on, OTHERWISE ARISING FROM COURSE OF DEALING, COURSE OF PERFORMANCE, OR
c) Electromechanical pad-mounted Slide and Swing operators: Five Years or USAGE OF TRADE.
500,000 cycles (whichever occurs first) a�er the date of installa�on, except
3. Buyer’s Exclusive Remedies for Any Nonconformity.
single family residen�al usage, where the warranty term shall be Seven Years
If a HySecurity product fails to conform to the warran�es in Sec�on 1, Buyer must
a�er the date the product was shipped from HySecurity,
no�fy and order replacement parts from the Distributor through which the product
d) Electromechanical linear actuator Swing operators: Two Years a�er the date of
was purchased within a reasonable �me and in no event more than thirty (30) days
installa�on,
a�er the discovery of the nonconformity. HySecurity will inves�gate and, in the event
e) Electromechanical surface mount wedge operator electronics: Two Years or
of a breach, will provide, within a reasonable period of �me, one of the following:
500,000 gate cycles (whichever occurs first), a�er the date of installa�on,
(1) repair or replacement of any nonconforming products or components or
f) Electromechanical Barrier Arm Operators: Two years or 1,000,000 gate cycles
(2) refund of the price upon return of the nonconforming items. HySecurity reserves
(whichever occurs first) a�er the date of installa�on,
the right to supply used or recondi�oned material for all warranty claims. HySecurity
provided that the preceding Five Year warranty period in (a), (b), and (c) will not
will not be considered to be in breach of or default under this Warranty because of
extend beyond seven years from the date that the product was shipped from
any failure to perform due to condi�ons beyond its reasonable control, including any
HySecurity, and the Two Year warranty period in (b), (d), (e), and (f) will not extend
force majeure. This warranty does not cover any incidental expenses, including fines
beyond four years from the date that the product was shipped from HySecurity.
or penal�es, temporary security, labor, shipping, travel �me or standby �me that are
The preceding warranty dura�ons do not apply to the products or components
incurred for inspec�on or replacement of any nonconforming items. As a condi�on of
described below (g-j), which have a shorter warranty period:
warranty coverage, warranty claims must be submited in accordance with the
g) Hydraulic gate operator drive wheels, including XtremeDrive™ wheels and rack:
procedures described on the HySecurity form, “RMA Procedures.”
Two Years from date of installa�on.
THE REMEDY SELECTED BY HYSECURITY IN ACCORDANCE WITH THIS PARAGRAPH
h) AC and DC power supplies, chargers, and inverters and HyNet™ Gateway: Two
SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH OF
Years from date of installa�on, except bateries.
WARRANTY.
i) Bateries: One Year from date of shipment from HySecurity.
j) Components subject to normal wear including, but not limited to, chains, belts, 4. Exclusion of Consequen�al and Incidental Damages.
idler wheels, sprockets and fuses: One Year from date of installa�on. HYSECURITY SHALL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL, OR
1(b) HySecurity Products Not Purchased Through an Authorized Distributor or Not CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NONDELIVERY OR FROM
Properly Registered within 60 Days THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE
For any product that is not purchased from an authorized HySecurity distributor or PRODUCT OR FROM HYSECURITY’S OWN NEGLIGENCE. This exclusion applies
for which the product registra�on was not completed by the Dealer/Installer/End regardless of whether such damages are sought for breach of warranty, breach of
User within sixty (60) days of the date of purchase, the following warranty will apply: contract, negligence, or strict liability. This exclusion does not apply to claims for
HySecurity warrants that the product will remain serviceable for the following bodily injury or death.
periods, which begin on the date that the product was shipped from HySecurity: 5. Severability.
a) All gate operators: One Year or 100,000 gate cycles, whichever comes first. If any provision of this warranty is found to be invalid or unenforceable, then the
b) AC and DC power supplies, chargers, or inverters: One Year. remainder shall have full force and effect.
c) HyNet™ Gateway: One Year. 6. Proprietary Rights.
d) Hydraulic gate operator drive wheels: One Year. HySecurity retains and reserves all right, �tle, and interest in the intellectual
1(c) Replacement Parts property rights of its products, including any accompanying proprietary so�ware. No
HySecurity warrants that replacement parts (whether new or recondi�oned) will ownership of any intellectual property rights in the products or accompanying
remain serviceable for One Year from the date that the part was shipped from so�ware is transferred to Distributor, Dealer/Installer, or End User.
HySecurity or the remaining period of the Gate Operator warranty, whichever is 7. Applicable Law.
longer. This warranty will be interpreted, construed, and enforced in all respects in
1(d) Limita�ons and Exclusions Applicable to Each of the Preceding Warran�es. accordance with the laws of the State of Washington, without reference to its choice
The preceding warran�es shall not apply to equipment that has been (1) installed, of law principles. The U.N. Conven�on on Contracts for the Interna�onal Sale of
maintained, or used improperly or contrary to instruc�ons; (2) subjected to Goods will not apply to this warranty.
negligence, accident, vandalism, or damaged by severe weather, wind, flood, fire,
* HySecurity manufacturers only reliable and powerful gate operators and provides an extra margin of power to be certain the gate works in adverse conditions. Some manufactures
overstate the length and weight capacity of their operators, but HySecurity rates conservatively. Note that our pull force ratings are substantial and that extra margin of power is part of
the HySecurity reputation for reliability.
** Speed setting cannot be configured to exceed 1 ft/s for Class I and II usage.
*** Not for residential use or applications intended to serve the general public.
† The actual number of gate cycles available from battery depends upon gate resistance to travel, cycle length, battery size, state of charge and health, ambient temperature, accessory
power draw and frequency of gate cycles during power outage.
To enable fully automatic operation, all SLIDE gate operators require a minimum of TWO monitored external entrapment protection sensors (one for each direction) to protect
entrapment zones in both the open and close direction of travel. Visit hysecurity.com/gatesafety for more information on UL 325 standards and gate safety.
Contact Information: Visit support.hysecurity.com for Installation manuals, replacement part instructions,
part diagrams and more. Qualified Nice | HySecurity distributors are experienced and trained to assist in resolving
installation problems. For the name of a qualified distributor near you, call HySecurity at 800-321-9947. *Before
contacting your distributor or HySecurity Technical Support, obtain the serial number of your operator.
136 support.hysecurity.com