Single Seal Gland Designed for use with Unarmoured Cable

PRODUCT TYPE A IEC 62444 : EN 62444 : BS 6121 : IP66 : IP68

PART NUMBERS:

A 1 L B

2 S

3 A

PRODUCT DESCRIPTION
“A” type glands are commonly referred to as “stuffing glands”. They provide a controlled, pull
resistant environmental displacement seal on the cable outer sheath, minimising damage to cables
that exhibit “cold flow” characteristics. The gland maintains IP66 & IP68 to 50 metres. Options are
available for use with LSOH cables and extreme temperature applications.

COMPLIANCE STANDARDS:
IEC 62444
EN 62444
EXAMPLE PART NUMBERING:
A2LB/NP/20/M20

A Gland featuring controlled displacement sealing BS 6121

CERTIFICATION:
Neoprene Seal (2) - Silicone Seal (3) - Neoprene/Lead (1) - Silicone/ ABS Specified ABS Rules
2
Lead (4)

CERTIFICATE NO.
L Peppers Standard Designation 20-LD1944057-PDA

OPTIONAL
ACCESSORIES:
B Aluminium (A) / Brass (B) / Stainless Steel (S)
LOCKNUT Brass (ACBLN) / St Steel (ACSLN) / Aluminium (ALALN)

C PVC Shroud (C) - PCP Shroud (P) - Silicone LSOH Shroud (3) EARTH TAG Brass (ACBET) / St Steel (ACSET) / Aluminium (ACAET)

K-V-H Locknut & Nylon (K), Fibre (V) or PTFE (H) IP Washer IP WASHERS Nylon (ACNSW) / Fibre (ACFSW) / PTFE (ACPSW)

T Including Earth Tag SERRATED WASHERS Stainless Steel (ACSSW)


OPTIONS

SHROUDS PVC (ACSPVC) / PCP (ACSPCP) / Silicone LSOH (ACSSIO)


S Including Serrated Washer

1 Quantity per kit


IP RATING: IP66 & IP68 (50 metres - 7 Days )

NP Nickel Plated Neoprene Seals -35°C to +90°C


OPERATING TEMP:

20 Gland shell size Silicone Seals -60°C to +180°C

MATERIALS: Aluminium, Brass, Stainless Steel


M20 M20 x 1.5mm Male Entry Thread

PLATING: Electroless Nickel


CABLE GLAND SELECTION TABLE
(ALL DIMENSIONS IN mm)

Cable Acceptance Details


Entry Thread Size Dimensions/Weight (Metric Versions)
Metric Thread Outer Sheath [D] Nominal Shroud
Gland Size Length Protrusion Size
[B] Length [L] Across Across Weight (Metric)
Metric NPT Min Max
Flats [A] Corners (Kgs)

12* M12 x 1.5 3/8” 16 0.9 6.0 33 19.0 21.0 0.038 L19
12* M16 x 1.5 3/8” or 1/2” 16 0.9 6.0 33 25.4 28.0 0.068 L24
12* M20 x 1.5 3/8” or 1/2” 16 0.9 6.0 33 25.4 28.0 0.082 L24
16 M16 x 1.5 3/8” or 1/2” 16 4.0 8.4 33 25.4 28.0 0.097 L24
16 M20 x 1.5 1/2” or 3/4” 16 4.0 8.4 33 25.4 28.0 0.104 L24**
20S M20 x 1.5 1/2” or 3/4” 16 7.2 11.7 33 25.4 28.0 0.102 L24**
20 M20 x 1.5 1/2” or 3/4” 16 9.4 14.0 33 30.0 33.0 0.127 L30
25 M25 x 1.5 3/4” or 1” 16 13.5 20.0 33 37.6 41.4 0.166 L38
32 M32 x 1.5 1” or 1 ¼” 16 19.5 26.3 33 46.0 50.6 0.244 L46
40 M40 x 1.5 1 ¼” or 1 ½” 16 23.0 32.2 37 55.0 60.5 0.396 L55
50S M50 x 1.5 1 ½” or 2” 16 28.1 38.2 37 65.0 71.5 0.558 L65
50 M50 x 1.5 2” 16 33.1 44.1 37 65.0 71.5 0.438 L65
63S M63 x 1.5 2” or 2 ½” 19 39.2 50.1 37 80.0 88.0 0.832 L80
63 M63 x 1.5 2 ½” 19 46.7 56.0 37 80.0 88.0 0.664 L80
75S M75 x 1.5 2 ½” or 3” 19 52.1 62.0 37 90.0 99.0 0.924 L90
75 M75 x 1.5 3” 19 58.0 68.0 37 90.0 99.0 0.714 L90
80 M80 x 2.0 3” or 3 ½” 25 62.2 72.0 50 104.0 115.2 1.514 L104
85 M85 x 2.0 3” or 3 ½” 25 69.0 78.0 50 104.0 115.2 1.332 L104
90 M90 x 2.0 3 ½” or 4” 25 74.0 84.0 50 114.0 125.7 1.622 L114
100 M100 x 2.0 3 ½” or 4” 25 82.0 90.0 50 114.0 125.7 1.523 L114
110 M110 x 2.0 - 25 87.0 102.0 88 135.0 148.0 2.550 N/A
120 M120 x 2.0 - 25 97.0 112.0 88 145.0 159.0 3.200 N/A
130 M130 x 2.0 - 25 107.0 122.0 88 155.0 170.0 4.750 N/A

 Gland size does not necessarily equate to the entry thread size.  When selecting IP Washer & Shroud material for use with glands, please be aware of the
NOTES

 Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our accessories temperature range to ensure they are suitable for the intended installation.
“Thread Reference Tables” for specific dimensions. * Gland sizes 12 not available in aluminium.
 Assembly instructions must be read prior to installation and adhered to in full. ** For gland sizes 16 and 20S when used with 3/4" NPT entry thread an L30 shroud would be
 Peppers supply products with parallel entry threads that conform to the flameproof threaded joint required.
requirements of IEC/EN 60079-1 and other equivalent standards. We usually incorporate a thread
run out according to general machining techniques and parts will not have a full form thread for
the entire length. Peppers Cable Glands Limited will not be held responsible for clients’ installations
where this has not been taken into account.

Peppers Cable Glands Ltd: www.peppers.co.uk | Email: sales@peppers.co.uk | Tel: +44 (0) 1276 64232 73
Industrial Cable Gland

A1A2 Cable Gland CXT Cable Gland

Size : 16mm to 90mm & ½" to 3½” Thread : Metric, NPT Size : 16mm to 90mm Thread : Metric, NPT
Standard : BS 6121: Part-1:2005, EN 50262: 1999, Operating Temp. : -20°C to +80°C Standard : BS 6121: Part-1:2005, EN 50262:1999, Operating Temp. : -20°C to +80°C
IEC62444:2010 Features : Outer Compression Seal
IEC62444:2010 Features : Compression Seal
Function : Providing environmental seal on outer Seal Material : Neoprene
Function : Providing seal on outer sheaths of all types of Cable Type : Unarmoured Cable sheaths of all types of unarmoured c a b l e
unarmoured cable in indoor and outdoor area. Seal Material : Neoprene Seal in indoor and outdoor area. Accessories : PVC Shroud, Earth Tag, Galvanized Steel
Ingress Protection : IP66 Lock Nut and Brass Washer
Accessories : PVC Shroud, Earth Tag, Thread Seal, Ingress Protection : IP66
Material : Brass CW614N, Stainless Steel 316L Cable Type : All types of screened flexible wire braid
Serrated Washer Material : Brass CW614N, Stainless Steel 316L (e.g. CY/SY) or wire braid armoured cable

Gland Selection Chart


Standard Thread Optional Thread Cable Dia. A Protrusion
Size “C” Thread
Size Length “D” Length “F” A/F A/C
Metric NPT Metric NPT Min. Max. Gland Selection Chart
20s16 20 ½” 25 ¾” 10.00 3.10 8.60 25.75 22.00 24.00 Standard Thread Optional Thread
Size “C” Thread Cable Dia. A Protrusion
20S 20 25 10.00 6.10 11.70 25.75 22.00 24.00 Size Length “D” Length “F” A/F A/C
½” ¾”
Metric NPT Metric NPT Min. Max.
20 20 ½” 25 ¾” 10.00 6.50 13.90 26.25 26.00 28.50 20s16 20 ½” 25 ¾’ 10.00 3.10 8.60 25.75 22.00 24.00
25s 25 ¾” 32 1" 10.00 11.30 19.90 34.00 34.00 38.00 20S 20 ½” 25 ¾” 10.00 6.10 11.70 25.75 22.00 24.00
25 25 ¾” 32 1" 10.00 11.30 19.90 34.00 34.00 38.00 20 20 ½” 25 ¾” 10.00 6.50 13.90 26.25 26.00 28.50
32 32 1" 40 1¼” 10.00 17.00 26.20 35.00 40.00 45.00 25s 25 ¾” 32 1” 10.00 11.30 19.90 34.00 34.00 38.00
40 40 1¼” 50 1½” 15.00 23.60 32.10 35.00 47.50 51.50 25 25 ¾” 32 1” 10.00 11.30 19.90 34.00 34.00 38.00
50S 50 1½” 63 2" 15.00 31.50 38.20 33.00 54.00 58.00 32 32 1" 40 1¼” 10.00 17.00 26.20 35.00 40.00 45.00
50 50 2" 63 2½” 15.00 35.80 44.00 37.00 58.00 54.00 40 40 1¼” 50 1½” 15.00 23.60 32.10 35.00 47.50 51.50
63S 63 2" 75 2½” 15.00 41.70 50.00 34.25 66.00 72.00 50S 50 1½” 63 2” 15.00 31.50 38.20 33.00 54.00 58.00
63 63 2½” 75 3" 15.00 47.50 56.00 37.25 70.50 75.00 50 50 2" 63 2½” 15.00 35.80 44.00 37.00 58.00 54.00
75S 75 2½” 90 3" 15.00 55.00 62.00 40.75 78.00 85.00 63S 63 2" 75 2½” 15.00 41.70 50.00 34.25 66.00 72.00
75 75 3" 90 3½” 15.00 62.00 68.00 44.00 83.00 89.00 63 63 2½” 75 3” 15.00 47.50 56.00 37.25 70.50 75.00
90 90 3½” 100 4” 18.00 67.00 79.00 51.50 105.00 112.00 75S 75 2½” 90 3” 15.00 55.00 62.00 40.75 78.00 85.00
100 100 3½” 115 4" 20.00 77.00 90.20 144.0 124.00 134.00
75 75 3" 90 3½” 15.00 62.00 68.00 44.00 83.00 89.00
115 115 4" 130 5” 20.00 89.00 101.4 156.0 134.00 145.00
90 90 3½” 100 4” 18.00 67.00 79.00 51.50 105.00 112.00
130 130 5” - - 20.00 97.00 115.0 156.0 145.00 155.00
Product Code for Ordering Purpose
Product Code for Ordering Purpose
Size Type Material Thread Type Shroud Type Accessories
Size Type Material Thread Type Shroud Type Accessories
20s16 CXT Brass-1 Standard Metric-11 PVC Shroud-PS Steel Lock Nut-4
20s16 A1A2 Brass-1 Standard Metric-11 PVC Shroud-PS Steel Lock Nut-4
Stainless Steel-2 Standard NPT-12 LSF Shroud-LS Steel Lock Nut-5
Stainless Steel-2 Standard NPT-12 LSF Shroud-LS Brass Lock Nut-5
Nickel Plated-3 Optional Metric-16 IP Washer-6
Nickel Plated-3 Optional Metric-16 IP Washer-6
Optional NPT-17
Optional NPT-17
How to Order ?
How to Order ? 20s16=Gland Size, A1CXT=Gland Code,
20s16=Gland Size, A1A2=Gland Code, Item Code: 20s16A1CXT 1 11 PS 4
Item Code: 20s16A1A2 1 11 PS 4 1= With Brass Material,11=With Standard Metric Thread,
1= With Brass Material, 11=With Standard Metric Thread, Code Meaning: CXT-20s16 Brass Cable Gland.
Code Meaning: A1A2-20s16 Brass Cable Gland. PS= With PVC Shroud, 4=With Steel Lock Nut.
PS= With PVC Shroud, 4=With Steel Lock Nut.

123 124
ELECTRICAL SOLUTIONS
A.
System
Overview

Ring Terminal, Non-Insulated


B1.
Cable Ties
Type P-R
• Ring tongue design assures a secure connection in high • Barrel of terminal internally beveled to provide quick and easy
vibration applications wire insertion B2.
Cable
• Internal barrel serrations assure good wire contact and maximum • Maximum recommended operating temperature 302°F (150°C) Accessories
tensile strength • UL and CSA rated up to 2000 V per UL 486A/B
• Brazed seam protects terminal barrel from splitting during the
crimp process B3.
Stainless
Steel Ties
Stock Figure Dimensions Recommended Std. Std.
Wire Thickness Stud (In.) Installation Pkg. Ctn.
Part Number Range (In.) Size L W C Tool Qty.** Qty. C1.
P22-2R-C* 0.02 #2 0.52 0.20 0.16 100 1000 Wiring
Duct
P22-4R-C* 0.02 #4 0.52 0.20 0.16 100 1000
P22-6R-C* 26 – 22 0.02 #6 0.52 0.20 0.16 100 1000
CT-200
AWG
P22-8R-C* 0.02 #8 0.63 0.26 0.25 100 1000 C2.
P22-10R-C*
Surface
0.02 #10 0.63 0.31 0.22 100 1000
Raceway
P18-4R-C 0.03 #4 0.62 0.25 0.21 100 1000
P18-6RN-C 0.03 #6 0.60 0.22 0.19 100 1000
P18-6R-C 0.03 #6 0.62 0.25 0.21 100 1000 C3.
CT-100A‡, Abrasion
P18-8R-C 0.03 #8 0.71 0.31 0.25 100 1000 Protection
L CT-200‡,
P18-10R-C 22 – 16 0.03 #10 0.71 0.31 0.25 100 1000
CT-600-A‡,
AWG
P18-14R-C 0.03 1/4" 0.91 0.46 0.38 CT-1570‡, 100 1000
CT-2500‡ C4.
P18-56R-C 0.03 5/16" 0.91 0.46 0.38 100 1000 Cable
W P18-38R-C 0.03 3/8" 1.0 0.53 0.43 100 1000 Management
P18-12R-C 0.03 1/2" 1.20 0.72 0.53 100 1000
C P14-4R-C 0.03 #4 0.62 0.25 0.20 100 1000
P14-6R-C 0.03 #6 0.62 0.25 0.20 100 1000 D1.
Terminals
P14-8R-C 0.03 #8 0.71 0.31 0.25 CT-100A‡, 100 1000
P14-10R-C 0.03 #10 0.71 0.31 0.25 CT-200‡, 100 1000
18 – 14
CT-600-A‡,
P14-14R-C AWG 0.03 1/4" 0.91 0.46 0.38 100 1000
CT-1570‡, D2.
P14-56R-C 0.03 5/16" 0.91 0.46 0.38 CT-2500‡ 100 1000 Power
P14-38R-C 0.03 3/8" 1.0 0.53 0.43 100 1000 Connectors
P14-12R-L 0.03 1/2" 1.20 0.72 0.53 50 500
P10-6R-L^ 0.04 #6 0.78 0.31 0.31 50 500 D3.
P10-8R-L 0.04 #8 0.78 0.31 0.31 50 500 Grounding
CT-100A‡,
Connectors
P10-10R-L^ 0.04 #10 0.81 0.38 0.31 CT-200‡, 50 500
P10-14R-L 14 – 10 0.04 1/4" 0.96 0.52 0.38 CT-600-A‡, 50 500
AWG CT-1570‡,
P10-56R-L^ 0.04 5/16" 0.95 0.52 0.38 CT-1701‡, 50 500 E1.
P10-38R-L^ 0.04 3/8" 1.05 0.58 0.44 CT-2500‡ 50 500 Labeling
Systems
P10-12R-L 0.04 1/2" 1.20 0.72 0.53 50 500

*Wire sizes #26 – 22 AWG are not UL Listed or CSA Certified.


**Bulk packaging may be available, contact Panduit Customer Service for additional information. E2.
^For military specification cross reference see page D1.96. Labels
‡UL and CSA approved tooling/product combinations. For crimping tool information, see pages D1.83, D1.84,
D1.86 and D1.88.
E3.
Pre-Printed
& Write-On
Markers

E4.
Permanent
Identification

E5.
Lockout/
Tagout
& Safety
Solutions

F.
Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) D1.17
ELECTRICAL SOLUTIONS
A.
System
Overview
Part Number System for Metric Lugs

B1.
Cable Ties

B2.
Cable
Accessories

B3.
Stainless
Steel Ties
LCMA 150 – 10 – X
150 = 150mm2 10 = 10mm 1=1 X = 10 C = 100
5=5 L = 50 C1.
Wiring
Part Number System for Pan-Lug ™ Compression Metric Lugs Duct

LCMA 150 — 10 — X C2.


Surface
Raceway
Type Conductor Stud Hole Standard Package Size
Size Size
1 =1 C3.
5 = #5 Abrasion
6 = 6mm 5 =5 Protection
8 = 8mm 6 =6
10 = 10mm X = 10 C4.
12 = 12mm Q = 25 Cable
Management
14 = 14mm L = 50
16 = 16mm C = 100
20 = 20mm D1.
00 = Blank Tongue* Terminals

Metric Conductor, One-Hole, Standard Barrel with Window Lug D2.


Power
Connectors
For Use with Class 2 Stranded Copper Conductors
Type LCMA
D3.
• Inspection window to visually assure full conductor insertion • Product information marked on connector for selection
Grounding
• Tin-plated to inhibit corrosion and installation Connectors
• UL Listed, UL Recognized, and CSA Certified to 35 KV** and • Rounded tongue convenient for use in tight spaces
temperature rated to 90°C when crimped with Panduit tools • Internally beveled wire entry for fast and easy installation
E1.
and dies Labeling
D Systems

B B
E2.
N Labels
M
INSPECTION
INSPECTION WINDOW E3.
WINDOW I Pre-Printed
I & Write-On
Markers
L
L
E4.
Copper Figure Dimensions Permanent
Conductor (mm) Identification
Size Current Stud Hole Panduit Std.
Part Class 2R Rating Size Die Index Pkg. E5.
Number (mm²) (Amps) (mm) ØI B M N L ØD No.‡ Qty. Lockout/
LCMA6-5-C* 4–6 30 M5 3.8 10.0 7.8 6.2 27.5 5.5 P10 100 Tagout
LCMA6-6-C* 4–6 30 M6 3.8 10.8 7.8 6.2 27.5 6.6 P10 100 & Safety
LCMA6-8-C* 4–6 30 M8 3.8 13.0 8.0 8.0 30.5 9.0 P10 100 Solutions

‡See page D3.83 for tool and die information.


*UL Recognized only. F.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. Table continues on page D2.108 Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) D2.107
ELECTRICAL SOLUTIONS
A.
System
Overview
Metric Conductor, One-Hole, Standard Barrel with
Window Lug (continued)
B1.
Cable Ties Figure Dimensions
Copper (mm)
Conductor Current Stud Hole Panduit Std.
Part Size Rating Size Die Index Pkg.
B2. Number Class 2R (mm²) (Amps) (mm) ØI B M N L ØD No.‡ Qty.
Cable LCMA10-5-C 10 — M5 4.5 11.0 9.8 6.0 30.8 5.5 P21 100
Accessories LCMA10-6-C 10 — M6 4.5 11.0 9.8 6.0 30.8 6.6 P21 100
LCMA10-8-C 10 — M8 4.5 13.0 8.5 8.0 30.8 9.0 P21 100
B3. LCMA10-10-C 10 — M10 4.4 14.5 8.5 8.0 30.8 11.0 P21 100
Stainless LCMA16-5-C* 16 65 M5 5.5 13.0 10.3 6.5 34.5 5.5 P24 100
Steel Ties LCMA16-6-C* 16 65 M6 5.5 13.0 10.3 6.5 34.5 6.6 P24 100
LCMA16-8-C* 16 65 M8 5.5 13.0 10.3 6.5 34.5 9.0 P24 100
LCMA16-10-C* 16 65 M10 5.5 15.0 10.2 8.0 36.7 11.0 P24 100
C1.
Wiring LCMA25-6-C 25 — M6 6.9 14.0 10.0 8.0 37.0 6.6 P29 100
Duct LCMA25-8-C 25 — M8 6.9 15.5 10.0 8.0 37.0 9.0 P29 100
LCMA25-10-C 25 — M10 6.9 15.5 10.0 8.0 37.0 11.0 P29 100
LCMA35-6-C 35 — M6 8.2 15.5 12.3 8.5 42.0 6.6 P29 100
C2. LCMA35-8-C 35 — M8 8.2 15.5 12.3 8.5 42.0 9.0 P29 100
Surface
Raceway LCMA35-10-C 35 — M10 8.2 15.5 12.3 8.5 42.0 11.0 P29 100
LCMA35-12-C 35 — M12 8.2 21.5 14.5 11.5 48.0 14.0 P29 100
LCMA50-6-L 50 — M6 9.8 18.0 11.5 10.0 46.5 6.6 P37 50
C3. LCMA50-8-L 50 — M8 9.8 18.0 11.5 10.0 46.5 9.0 P37 50
Abrasion LCMA50-10-L 50 — M10 9.8 18.0 11.5 10.0 46.5 11.0 P37 50
Protection
LCMA50-12-L 50 — M12 9.8 23.0 14.0 11.0 50.0 14.0 P37 50
LCMA70-6-L 70 — M6 11.5 20.8 14.5 11.5 53.5 6.6 P45 50
C4. LCMA70-8-L 70 — M8 11.5 20.8 14.5 11.5 53.5 9.0 P45 50
Cable LCMA70-10-L 70 — M10 11.5 20.8 14.5 11.5 53.5 11.0 P45 50
Management
LCMA70-12-L 70 — M12 11.5 20.8 14.5 11.5 53.5 14.0 P45 50
LCMA95-8-L 95 — M8 13.5 24.5 15.0 13.5 60.5 9.0 P54 50
LCMA95-10-L 95 — M10 13.5 24.5 15.0 13.5 60.5 11.0 P54 50
D1.
LCMA95-12-L 95 — M12 13.5 24.5 15.0 13.5 60.5 14.0 P54 50
Terminals
LCMA95-16-L 95 — M16 13.5 24.5 15.0 13.5 60.5 18.0 P54 50
LCMA120-8-L 120 — M8 15.2 27.5 15.5 14.5 65.0 9.0 P62 50
LCMA120-10-L 120 — M10 15.2 27.5 15.5 14.5 65.0 11.0 P62 50
D2.
Power LCMA120-12-L 120 — M12 15.2 27.5 15.5 14.5 65.0 14.0 P62 50
Connectors LCMA120-16-L 120 — M16 15.2 27.5 15.5 14.5 65.0 18.0 P62 50
LCMA150-8-X 150 — M8 16.5 30.5 18.0 16.5 70.5 9.0 P66 10
LCMA150-10-X 150 — M10 16.5 30.5 18.0 16.5 70.5 11.0 P66 10
D3.
LCMA150-12-X 150 — M12 16.5 30.5 18.0 16.5 70.5 14.0 P66 10
Grounding
Connectors LCMA150-16-X 150 — M16 16.5 30.5 18.0 16.5 70.5 18.0 P66 10
LCMA150-20-X 150 — M20 16.5 30.5 22.0 16.5 74.0 22.0 P66 10
LCMA185-10-X 185 — M10 18.6 33.5 16.5 17.5 72.5 11.0 P76 10
E1. LCMA185-12-X 185 — M12 18.6 33.5 16.5 17.5 72.5 14.0 P76 10
Labeling
LCMA185-16-X 185 — M16 18.6 33.5 16.5 17.5 72.5 18.0 P76 10
Systems
LCMA185-20-X 185 — M20 18.6 33.5 21.0 17.5 77.0 22.0 P76 10
LCMA240-10-X 240 — M10 20.8 37.5 21.0 19.5 86.5 11.0 P87 10
LCMA240-12-X 240 — M12 20.8 37.5 21.0 19.5 86.5 14.0 P87 10
E2.
Labels LCMA240-16-X 240 — M16 20.8 37.5 21.0 19.5 86,5 18.0 P87 10
LCMA240-20-X 240 — M20 20.8 37.5 21.0 19.5 86.5 22.0 P87 10
LCMA300-10-5 300 — M10 23.5 42.5 22.0 20.0 94.5 11.0 P94 5
E3. LCMA300-12-5 300 — M12 23.5 42.5 22.0 20.0 94.5 14.0 P94 5
Pre-Printed
LCMA300-16-5 300 — M16 23.5 42.5 22.0 20.0 94.5 18.0 P94 5
& Write-On
Markers LCMA300-20-5 300 — M20 23.5 42.5 22.0 20.0 94.5 22.0 P94 5
LCMA400-12-5 400 — M12 27.0 49.5 26,5 23.5 107.0 14.0 P106 5
E4. LCMA400-16-5 400 — M16 27.0 49.5 26.5 23.5 107.0 18.0 P106 5
Permanent LCMA400-20-5 400 — M20 27.0 49.5 26.5 23.5 107.0 22.0 P106 5
Identification LCMA500-12-1 500 — M12 31.0 57.5 28,5 25.5 120.0 14.0 P125 1
LCMA500-16-1 500 — M16 31.0 57.5 28.5 25.5 120.0 18.0 P125 1
E5. LCMA500-20-1 500 — M20 31.0 57.5 28.5 25.5 120.0 22.0 P125 1
Lockout/
Tagout LCMA500-00-1* 500 — Blank 31.0 57.5 — — 120.0 — P125 1
& Safety LCMA630-16-1 630 — M16 34.5 63.0 28.5 27.5 131.0 18.0 P125 1
Solutions LCMA630-20-1 630 — M20 34.5 63.0 28.5 27.5 131.0 22.0 P125 1
LCMA630-00-1* 630 — Blank 34.5 63.0 — — 131.0 — P125 1
F. ‡See page D3.83 for tool and die information.
Index *UL Recognized only.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
D2.108 Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview

Ring Terminal, Vinyl Insulated – Funnel Entry


B1.
Cable Ties
Type PV-R
• Insulation support helps to prevent wire damage in • Internal barrel serrations assure good wire contact and maximum
bending applications tensile strength B2.
Cable
• Ring tongue design assures a secure connection in high • UL Flammability UL 94V-0, maximum insulation temperature Accessories
vibration applications 221°F (105°C)
• Brazed seam protects terminal barrel from splitting during the • UL and CSA rated up 600 V per UL 486A/B
crimp process B3.
Stainless
Steel Ties

Stock Max. Figure Dimensions Recommended Std. Std.


Wire Color Thickness Ins. Stud (In.) Installation Pkg. Ctn. C1.
Part Number Range Code (In.) (In.) Size L W C Tool Qty.** Qty. Wiring
PV22-2R-CY* 0.02 0.110 #2 0.68 0.21 0.18 100 1000 Duct
PV22-4R-CY* 0.02 0.110 #4 0.68 0.21 0.18 100 1000
CT-600-A,
0.1 - 0.5 mm2 PV22-6R-CY* 26 – 22 Yellow 0.02 0.110 #6 0.68 0.21 0.18 CT-1525, 100 1000 C2.
AWG
PV22-8R-CY* 0.02 0.110 #8 0.78 0.26 0.26 CT-2500 100 1000 Surface
PV22-10R-CY* 0.02 0.110 #10 0.78 0.32 0.24 100 1000 Raceway
PV18-4R-CY 0.03 0.150 #4 0.84 0.25 0.22 100 500
PV18-6R-CY 0.03 0.150 #6 0.86 0.25 0.22 100 500 C3.
PV18-8R-CY 0.03 0.150 #8 0.91 0.31 0.26 100 500 Abrasion
CT-100A‡,
Protection
0.5 - 1.5 mm2 PV18-10R-CY 22 – 18 0.03 0.150 #10 0.94 0.31 0.27 CT-600-A‡, 100 500
Red CT-1550‡,
PV18-14R-CY AWG 0.03 0.150 1/4" 1.11 0.46 0.37 100 500
L CT-1551‡,
PV18-56R-CY 0.03 0.150 5/16" 1.11 0.46 0.39 CT-2500‡ 100 500 C4.
Cable
PV18-38R-LY 0.03 0.150 3/8" 1.19 0.53 0.42 50 500
Management
W PV18-12R-LY 0.03 0.150 1/2" 1.42 0.72 0.53 50 500
PV14-4R-C 0.03 0.170 #4 0.84 0.25 0.19 100 500
C PV14-6RN-C 0.03 0.170 #6 0.84 0.25 0.19 100 500 D1.
PV14-6R-C 0.03 0.170 #6 0.92 0.31 0.25 100 500 Terminals
PV14-8R-C 0.03 0.170 #8 0.92 0.31 0.25 CT-100A‡, 100 500
CT-600-A‡,
1.5 - 2.5 mm2 PV14-10R-C 16 – 14
AWG
Blue 0.03 0.170 #10 0.92 0.31 0.25 CT-1550‡, 100 500
D2.
PV14-14R-C 0.03 0.170 1/4" 1.12 0.46 0.38 CT-1551‡, 100 500
CT-2500‡ Power
PV14-56R-C 0.03 0.170 5/16" 1.12 0.46 0.38 100 500 Connectors
PV14-38R-L 0.03 0.170 3/8" 1.21 0.53 0.43 50 500
PV14-12R-L 0.03 0.170 1/2" 1.42 0.72 0.53 50 500
D3.
PV10-6R-L 0.04 0.225 #6 1.05 0.31 0.31 50 500 Grounding
PV10-8R-L 0.04 0.225 #8 1.05 0.31 0.31 50 500 Connectors
PV10-10R-L 0.04 0.225 #10 1.05 0.31 0.31 CT-100A‡, 50 500
CT-600-A‡,
4.0 - 6.0 mm2 PV10-14R-L 12 – 10
Yellow 0.04 0.225 1/4" 1.23 0.52 0.38 CT-1550‡, 50 500 E1.
AWG
PV10-56R-L 0.04 0.225 5/16" 1.23 0.52 0.38 CT-1551‡, 50 500 Labeling
CT-2500‡ Systems
PV10-38R-L 0.04 0.225 3/8" 1.31 0.58 0.41 50 500
PV10-12R-Q 0.04 0.225 1/2" 1.46 0.72 0.53 25 250

*Wire sizes #26 – 22 AWG, are not UL Listed or CSA Certified. E2.
**Bulk packaging may be available, contact Panduit Customer Service for additional information. Labels
‡UL and CSA approved tooling/product combinations. For crimping tool information, see pages D1.83, D1.84,
D1.86 and D1.88.
E3.
Pre-Printed
& Write-On
Markers

E4.
Permanent
Identification

E5.
Lockout/
Tagout
& Safety
Solutions

F.
Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) D1.9
ELECTRICAL SOLUTIONS
A.
System
Overview

Fork Terminal, Vinyl Insulated – Funnel Entry


B1.
Cable Ties
Type PV-F
• Fork design provides for fast and easy installation, without the • Internal barrel serrations assure good wire contact and maximum
need to remove fastener tensile strength B2.
• Insulation support helps to prevent wire damage in • UL Flammability UL 94V-0, maximum insulation temperature Cable
bending applications 221°F (105°C) Accessories
• Brazed seam protects terminal barrel from splitting during the • UL and CSA rated up 600 V per UL 486A/B
crimp process B3.
Stainless
Figure Dimensions Recommended Std. Std. Steel Ties
Stock Max.
Wire Color Thickness Ins. Stud (In.) Installation Pkg. Ctn.
Part Number Range Code (In.) (In.) Size L W C Tool Qty.** Qty.
C1.
PV22-2F-CY* 0.02 0.110 #2 0.61 0.20 0.19 100 1000 Wiring
CT-600-A,
PV22-4F-CY* 26 – 22 0.02 0.110 #4 0.67 0.20 0.21 100 1000 Duct
Yellow CT-1525,
0.1 - 0.5 mm2 PV22-6F-CY*
AWG
0.02 0.110 #6 0.76 0.25 0.26 CT-2500 100 1000
PV18-6FN-CY* 0.03 0.150 #6 0.85 0.24 0.21 100 500
C2.
PV18-6F-CY 0.03 0.150 #6 0.86 0.30 0.21 CT-100A‡, 100 500 Surface
CT-600-A‡,
22 – 16 Raceway
0.5 - 1.5 mm2 PV18-8F-CY
AWG
Red 0.03 0.150 #8 0.93 0.32 0.25 CT-1550‡,
CT-1551‡,
100 500
PV18-10FN-CY* 0.03 0.150 #10 0.93 0.31 0.25 100 500
CT-2500‡
PV18-10F-CY 0.03 0.150 #10 0.93 0.35 0.25 100 500 C3.
PV14-6FN-C* 0.03 0.170 #6 0.84 0.24 0.19 100 500 Abrasion
Protection
PV14-6F-C 0.03 0.170 #6 0.84 0.28 0.19 CT-100A‡, 100 500
CT-600-A‡,
1.5 - 2.5 mm2 PV14-8F-C 16 – 14
Blue
0.03 0.170 #8 0.90 0.31 0.23
CT-1550‡,
100 500
L PV14-10FN-C* AWG 0.03 0.170 #10 0.92 0.31 0.24 100 500 C4.
CT-1551‡,
PV14-10F-C 0.03 0.170 #10 0.92 0.34 0.24 100 500
Cable
CT-2500‡
Management
PV14-14F-C 0.03 0.170 1/4" 1.09 0.44 0.32 100 1000
W PV10-6F-L 0.04 0.225 #6 1.01 0.31 0.25 50 500
CT-100A‡,
PV10-8F-L 0.04 0.225 #8 1.04 0.37 0.25 CT-600-A‡, 50 500 D1.
C 14 – 10
Yellow CT-1550‡, Terminals
PV10-10F-L AWG 0.04 0.225 #10 1.04 0.37 0.25 50 500
CT-1551‡,
2.5 - 4.0 mm2 PV10-14F-L 0.04 0.225 1/4" 1.14 0.49 0.32 CT-2500‡ 50 500

*Not UL Listed or CSA Certified. D2.


**Bulk packaging may be available, contact Panduit Customer Service for additional information. Power
‡UL and CSA approved tooling/product combinations. For crimping tool information, see pages D1.83, D1.84, Connectors
D1.86 and D1.88.

D3.
Grounding
Connectors

E1.
Labeling
Systems

E2.
Labels

E3.
Pre-Printed
& Write-On
Markers

E4.
Permanent
Identification

E5.
Lockout/
Tagout
& Safety
Solutions

F.
Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) D1.23
ELECTRICAL SOLUTIONS
A.
System
Overview Selection Guide – Specialty Terminals
B1.
Page
Material Style Feature Type Number
Cable Ties
Pin Terminal Insulation Support PV-P D1.54
Vinyl
Blade Terminal Insulation Support DV-M D1.55
B2.
Cable
Accessories Specialty

B3. Pin Terminal Brazed Seam P-P D1.54


Stainless Non-Insulated
Steel Ties Blade Terminal Brazed Seam D-M D1.55

C1. Pin Terminal, Vinyl Insulated – Funnel Entry


Wiring
Duct Type PV-P
• Solid pin designed to prevent damage to the wire from over • Internal barrel serrations assure good wire contact and maximum
tightening, resulting in a reliable electrical connection tensile strength
C2.
Surface • Insulation support helps to prevent wire damage in • For use with pin-type terminal blocks
Raceway bending applications • UL Flammability UL 94V-0, maximum insulation temperature
• Brazed seam protects terminal barrel from splitting during the 221°F (105°C)
crimp process • UL rated up to 600 V per UL 486A/B
C3.
Abrasion Max. Figure Dimensions Recommended Std. Std.
Protection Color Ins. (In.) Installation Pkg. Ctn.
Part Number Wire Range Code (In.) L W P Tool Qty.** Qty.

C4. 0.5-1.5 mm2 PV18-P47-CY 22 – 18 AWG Red 0.150 0.97 0.07 0.49 100 1000
Cable CT-100A,
Management PV14-P47-C 16 – 14 AWG Blue 0.170 0.97 0.07 0.49 CT-260, 100 1000
1.5-2.5 mm2 CT-1550,
CT-1551,
PV10-P55-LY* 12 – 10 AWG Yellow 0.250 1.10 0.10 0.55 CT-2500 50 500
D1. 4.0-6.0 mm2
Terminals
*Not UL Listed.
L **Bulk packaging may be available, contact Panduit Customer Service for additional information.
For crimping tool information, see pages D1.83, D1.84, and D1.88.
D2.
Power
Connectors
P W

D3.
Grounding Pin Terminal, Non-Insulated
Connectors
Type P-P
• Solid pin designed to prevent damage to the wire from over • Barrel of terminal internally beveled to provide quick and easy
E1.
Labeling tightening, resulting in a reliable electrical connection wire insertion
Systems • Brazed seam protects terminal barrel from splitting during the • For use with pin-type terminal blocks
crimp process • Maximum recommended operating temperature 302°F (150°C)
• Internal barrel serrations assure good wire contact and maximum • UL rated up to 600 V per UL 486A/B
E2. tensile strength
Labels

Figure Dimensions Recommended Std. Std.


E3. (In.) Installation Pkg. Ctn.
Pre-Printed Part Number Wire Range L W P Tool Qty.** Qty.
& Write-On
P18-P47-C 22 – 18 AWG 0.75 0.07 0.49 100 1000
Markers CT-100A,
CT-200,
CT-260,
E4. CT-1570,
Permanent P14-P47-C 16 – 14 AWG 0.75 0.07 0.49 CT-2500 100 1000
Identification
P10-P55-L* 12 – 10 AWG 0.79 0.11 0.55 CT-100A, 50 500
CT-200,
E5. CT-260,
Lockout/ L CT-1570,
Tagout CT-2500
& Safety P
Solutions *Not UL Listed.
**Bulk packaging may be available, contact Panduit Customer Service for additional information.
‡UL and CSA approved tooling/product combinations. For crimping tool information, see pages D1.83, D1.84,
F. W and D1.88.
Index

D1.54 Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
6/3/2020 0301 KSS Nylon Cable Tie

0301 KSS Nylon Cable Tie

● Material: UL approved Nylon 66, 94V-2, with good tensile strength and insulation, not easy to get
aging.
● Color: Standard color is natural, black, other special colors are available upon request.
● Feature: Low Smoke and Halogen Free cable tie suitable for various industry, also household DIY
and gardening.
Max. operating temperature up to 85℃
● Application: One piece self-lock cable tie save the time and make effective for installation.

Miniature
※ CVT-070, 100 doesn't have minimum bundle diameter.
※ CV-200T tail
※ CV-300STZ, 180T, 190T tail Unit: mm
Item No. Min Loop
Length Max.
Width Tensile
Natural Black L Bundle
W Strength
Dia.
100 pcs / Bag 1000 pcs / Bag 100 pcs / Bag 1000 pcs / Bag mm inch lbs kgs
※ CVT-070 CVT-070K CVT-070B CVT-070KB 71.0 2 13/16" 1.60 11 7 3
※ CVT-100 CVT-100K CVT-100B CVT-100KB 103.0 4" 1.95 22 11 5

CV-060 CV-060K CV-060B CV-060KB 63.7 2 1/2" 2.40 11 18 8

CV-075 CV-075K CV-075B CV-075KB 75.0 3" 2.40 15


CV-080 CV-080K CV-080B CV-080KB 80.0 3 1/8" 2.50 16
CV-094 CV-094K CV-094B CV-094KB 96.0 3 3/4" 2.50 21
CV-100 CV-100K CV-100B CV-100KB 100.0 4" 2.50 22
120.0 4 3/4" 2.50 28
www.kss.com.tw/e4k/e4-3/E0301-1.asp? 1/4
6/3/2020 0301 KSS Nylon Cable Tie

CV-120S CV-120SK CV-120SB CV-120SKB


CV-140S CV-140SK CV-140SB CV-140SKB 142.0 5 1/2" 2.50 35
CV-150S CV-150SK CV-150SB CV-150SKB 155.0 6 1/8" 2.50 39
CV-165 CV-165K CV-165B CV-165KB 165.0 6 1/2" 2.50 43
CV-200M CV-200MK CV-200MB CV-200MKB 203.0 8" 2.50 55
CV-250S CV-250SK CV-250SB CV-250SKB 250.0 10" 2.50 68
CV-300M CV-300MB 300.0 11 7/8" 2.50 80
CV-400S CV-400SB 400.0 15 3/4" 2.50 116

Intermediate
※ CVT-070, 100 doesn't have minimum bundle diameter.
※ CV-200T tail
※ CV-300STZ, 180T, 190T tail Unit: mm
Item No. Min Loop
Length Max.
Width Tensile
Natural Black L Bundle
W Strength
Dia.
100 pcs / Bag 1000 pcs / Bag 100 pcs / Bag 1000 pcs / Bag mm inch lbs kgs
CV-120 CV-120K CV-120B CV-120KB 120.0 4 3/4" 3.20 28
CV-140 CV-140K CV-140B CV-140KB 142.0 5 1/2" 3.20 34
CV-150 CV-150K CV-150B CV-150KB 150.0 6" 3.60 36
CV-180 CV-180K CV-180B CV-180KB 180.0 7" 3.60 46
※ CV-180T CV-180TK CV-180TB CV-180TKB 180.0 7" 3.60 46

CV-200S CV-200SK CV-200SB CV-200SKB 203.0 8" 3.20 53


40 18
CV-200A CV-200AK CV-200AB CV-200AKB 203.0 8" 3.60 52
CV-250M CV-250MK CV-250MB CV-250MKB 250.0 10" 3.60 68
CV-265 CV-265K CV-265B CV-265KB 265.0 10 1/2" 3.60 73
CV-292 CV-292K CV-292B CV-292KB 292.0 11 1/2" 3.60 82
CV-330 CV-330B 330.0 13" 3.60 93
CV-368S CV-368SB 368.0 14 1/2" 3.60 105

Standard
※ CVT-070, 100 doesn't have minimum bundle diameter.
※ CV-200T tail
※ CV-300STZ, 180T, 190T tail Unit: mm
Item No. Min Loop
Length
Max. Tensile
Natural Black L Width
Bundle Strength
W
1000 pcs / Dia.
100 pcs / Bag 100 pcs / Bag 1000 pcs / Bag mm inch lbs kgs
Bag
CV- 50 22
CV-120L CV-120LK CV-120LB 120.0 4 3/4" 4.80 27
120LKB
CV- 160.0 6 1/4" 4.80 39
CV-160L CV-160LK CV-160LB
160LKB
CV-190 CV-190K CV-190B CV-190KB 190.0 7 1/2" 4.80 49
www.kss.com.tw/e4k/e4-3/E0301-1.asp? 2/4
6/3/2020 0301 KSS Nylon Cable Tie

※ CV-190T CV-190TK CV-190TB


CV- 190.0 7 1/2" 4.80 49
190TKB
CV-200 CV-200K CV-200B CV-200KB 203.0 8" 4.60 52
CV- 203.0 8" 4.80 52
CV-200D CV-200DK CV-200DB
200DKB

※ CV-200T CV-200TK CV-200TB


CV- 203.0 8" 4.60 52
200TKB
CV-250 CV-250K CV-250B CV-250KB 250.0 10" 4.80 68
CV-280 CV-280K CV-280B CV-280KB 280.0 11" 4.80 77
CV-300S CV-300SB 300.0 11 7/8" 4.80 83
CV-310 CV-310B 310.0 12" 4.80 86
CV-350 CV-350B 350.0 13 3/4" 4.60 98
CV-368 CV-368B 368.0 14 1/2" 4.80 105
CV-385 CV-385B 385.0 15 3/16" 4.80 110
CV-400 CV-400B 400.0 15 3/4" 4.60 116
CV-432 CV-432B 432.0 17" 4.80 125
CV-450M CV-450MB 450.0 17 3/4" 4.80 131
CV-500 CV-500B 500.0 19 11/16" 4.80 147
CV-550S CV-550SB 550.0 21 11/16" 4.80 162
CV-610S CV-610SB 610.0 24" 4.80 181
CV-635S CV-635SB 635.0 25" 4.80 189
CV-730S CV-730SB 730.0 28 3/4" 4.80 219
CV-914S CV-914SB 914.0 36" 4.80 278

▲ CV- 200.0 8" 4.60 48


CV-200Z CV-200ZK CV-200ZB
200ZKB

▲ CV- 280.0 11" 4.80 70


CV-280Z CV-280ZK CV-280ZB 75 34
280ZKB
▲ CV-300SZ CV-300SZB 300.0 11 7/8" 4.80 74
▲ CV-368Z CV-368ZB 368.0 14 1/2" 4.80 94

※▲ CV- CV- 300.0 11 7/8" 4.80 83 80 36


300STZ 300STZB

Heavy Duty
※ CVT-070, 100 doesn't have minimum bundle diameter.
※ CV-200T tail
※ CV-300STZ, 180T, 190T tail Unit: mm
Item No. Min Loop
Length Max.
Width Tensile
Natural Black L Bundle
W Strength
Dia.
100 pcs / Bag 1000 pcs / Bag 100 pcs / Bag 1000 pcs / Bag mm inch lbs kgs
CV-380S CV-380SB 380.0 15" 6.40 108 100 45
CV- 120 55
CV-120LL CV-120LLK CV-120LLB 120.0 4 3/4" 7.60 22
120LLKB
CV-150L CV-150LK CV-150LB CV-150LKB 150.0 6" 7.60 32

www.kss.com.tw/e4k/e4-3/E0301-1.asp? 3/4
6/3/2020 0301 KSS Nylon Cable Tie

CV-200L CV-200LK CV-200LB CV-200LKB 203.0 8" 7.60 52

CV-240L CV-240LK CV-240LB CV-240LKB 240.0 9 7/16" 7.60 61


CV-250L CV-250LB 250.0 10" 7.60 64
CV-280L CV-280LK CV-280LB CV-280LKB 280.0 11" 7.60 74
CV-300 CV-300B 300.0 11 7/8" 7.60 80
CV-340 CV-340B 340.0 13 1/2" 7.60 92
CV-360 CV-360B 360.0 14 3/16" 7.60 99
CV-370 CV-370B 370.0 14 9/16" 7.60 101
CV-380 CV-380B 380.0 15" 7.60 105
CV-380L CV-380LB 380.0 15" 8.00 105
CV-450 CV-450B 450.0 17 3/4" 8.00 128
CV-500L CV-500LB 500.0 19 11/16" 8.00 143
CV-550 CV-550B 550.0 21 11/16" 8.00 160
CV-610M CV-610MB 610.0 24" 7.60 177
CV-750 CV-750B 750.0 29 1/2" 7.50 223
CV-450L CV-450LB 450.0 17 3/4" 9.00 128
CV-550D CV-550DB 550.0 21 11/16" 9.00 160
CV-610 CV-610B 610.0 24" 9.00 177
CV-685 CV-685B 685.0 27" 9.00 202
CV-710 CV-710B 710.0 28" 9.00 209
CV-762 CV-762B 762.0 30" 9.00 227
175 80
CV-812 CV-812B 812.0 32" 9.00 243
CV-914 CV-914B 914.0 36" 9.00 275
CV-940 CV-940B 940.0 37" 9.00 284
CV-1168 CV-1168B 1,168.0 46" 9.00 356
CV-1219 CV-1219B 1,219.0 48" 9.00 372
CV-1500 CV-1500B 1,500.0 59" 9.00 462

www.kss.com.tw/e4k/e4-3/E0301-1.asp? 4/4
Products for Surface Protective Materials Products for Harness

22 PO (Polyolefin) SPV®: Overview 23 Tape for Wire Harnesses Low-VOC PVC Tape/Flame-retardant, heat-resistant and High heat-resistant PVC Adhesive Tape

PVC tape featuring Low-VOC, thin layer, heat-resistance and flame-retardant


PO SPV® is an environment-friendly surface protective material, which does not contain chlorine or
plasticizer. The PO SPV® product line-up offers many variations suitable for all sorts of applications. This tape was developed to protect and bundle the wire harness (electric wire) which run all over automobiles.
We are aiming to reduce vehicle's weight by making the tapes thinner as much as possible, and reducing the
The following is the line-up of polyolefin SPV® products, which all use special polyolefin film for their base. The numerous variations of PO SPV® VOC level which also contributes to a better environment. Heat-resistant and flame-retardant tapes are also used
products are intended to meet various surface protection needs. Each product is made to be effective according to the nature of the surface protection, in EV/HEV vehicle’s wire harness.
whether the surface is a metal sheet or plastic sheet, or whether the coated surfaces are to be protected during transportation or processing.

Max. Width Standard Length Color Features Applications


Product Group Product No. Thickness (mm)
(mm) (m) White Transparent Blue (translucent)
M Series M-6030 0.060 1,250 200 - Low-VOC PVC Adhesive Tapes For banding wire harnesses, identification and joint protection
A Series A-6050 0.065 1,250 100 - Flame-retardant tapes, heat-resistant tapes and other various products
C-6010 0.060 1,250 100 - - are available for many harnessing purposes.
Environment-friendly tape of low VOC.
C-100 0.060 1,250 200 - -
C-200 0.060 1,250 200 -
General binding tape also has a thin layer type of 0.070mm thickness Properties PVC Tape General PO Tape

C Series C-300 0.060 1,250 200 - Comparison of Base Properties Comparison of the Characteristics of
Heat-resistance, flame-retardant and High heat-resistant PVC Adhesive Tapes
C-400 0.060 1,250 200 - -
PVC adhesive tape 25
C-500 0.060 1,250 200 - -
Flame-retardant tape also has a thin layer type of 0.070mm thickness Strength
C-600 0.090 1,250 200 - -
20 Flame Elongation
Offers each temperature zone of heat-resistant type retardancy

Strength (N/19mm)
V Series V-420 0.055 1,250 200 - -

364CK2 0.050 1,250 100 - - 15 Oil Flexibility


resistance
364MK2 0.055 1,250 200 - -
364 type Structure 10 Fog Stress
3641FK2 0.043 1,250 200 - -
resistance relaxation
3643FK2 0.045 1,250 200 - - Low-VOC PVC Adhesive Tapes 5 Melting Easy to tear
Substrates: stainless steel BA plate, acrylic plate temperature
PVC Film Long-term heat
■ As small lot production may be required depending on the size and the color of the product, please consult our sales representative. Low-VOC 0 resistance
■ The above chart shows example of measured values, not guaranteed values. Type Adhesive 0 10 20 30 40 50
Elongation (%)

Products for harness


Low-VOC PVC Adhesive Tapes

Thickness Length
Product Product No. Color Applications
(mm) (m)

Surface Protective Materials General/bundling No. 2101TVH/No. 2101NVH Black 0.10 20 Low VOC emissions
General unity thin layer type,
Protection Film for Interior Parts SPV®-C-600 General/bundling No. 2117TVH/No. 2117NVH Black 0.070 35
Low VOC emission product
Black, Blue, Green, Yellow, White,
Low VOC emissions,
Color variation No. 2107TVH/No. 2107NVH Brown, Gray, Red, Orange, Pink, Light 0.13 20
Used for protection of automobile interior parts color identifi cation use
green, Sky blue, Purple, Transparent

SPV®-C-600 has been developed for protecting automobile interior parts, which are exposed to severe Flame-retardant No. 2100FRTV Black 0.11 25 Flame-retardant type
heat and UV radiation. This film can be perfectly applied to suit any specific location and surface size for Flame-retardant No. 2117FRTV Dark gray 0.070 35 Flame-retardant thin type
protection, as well as effectively prevents scratching and keeps the vehicles from getting dirty during the
No. 2237FRTV Orange, Gray 0.13 20 Heat-resistant, flame-retardant type
assembly process. Heat-resistant,
flame-retardant Fog-resistant, heat-resistant,
No. 2239FRTV Black 0.11 25
flame-retardant type
Features Applications No. 2207TVH 0.13 20 Heat-resistance temperature limit: 85°C
Can be used for interior parts with a wide choice of substrates; no adhesive residue General interior parts such as door trim, instrument panels and High heat Black
No. 2280TV 0.08 33 Heat-resistance temperature limit: 105°C
remains when peeled. door steps resistance (Please inquire for other colors)
No. 2290TV 0.11 33 Heat-resistance temperature limit: 125°C
Adheres well to rough surfaces.
Thicker No. 213JTV Black, Dark blue 0.30 10 Tube replacement use

Structure Insulation & Black, Blue, Green, Yellow, White,


No. 223S 0.190 20 Electronic insulation type
heat-resistant Gray, Red
Acrylic Adhesive *Symbols at the end of the product names: TV=Made in Taiwan
Polyethylene Film NV=Made in China

Standard Size

Product No. Thickness (mm) Width (mm) Length (m) Color


C-600 0.090 1,250 200 Transparent

21 22
Construction Solutions Indonesia

DINABOL SLEEVE ANCHOR Versatile Multi Functions Anchor Bolt

Aplikasi Produk

Dimensi

Fitur & Aplikasi Umum


• Dinabol ITEWE merupakan angkur multi fungsi dengan desain
sleeve unik dengan kemampuan ‘pulldown’ yang unik,
mengencangkan dengan kuat dan aman
• Pengangkuran langsung, tidak perlu penandaan dan reposisi
Bentuk kepala yang beragam
• Baut dapat mudah dilepas
• Tersedia untuk Finishing Zinc Plated, HDG dan Stainless Steel

Beban Disain Indikasi Pada Beton

ISO 9001 : 2015 ITEWE is registered brand under


PT. ITEWE Sarana Konstruksi,
ISO 14001 : 2015 a quality construction products supplier
ISO 45001 : 2018 company in Indonesia.
Round
Hex Bolt Head Bolt

Square Washer Flat Washer Spring Washer

U Bolt
Hex Nut
Asdrat
Long Nut

Steel Angle Steel Channel


ELECTRICAL SOLUTIONS
A.
System
Overview

Part Number System for Non-Shrink PVC Tubing


B1. TV105 – 12 M
Cable Ties
Type Nominal Size Package Quantity Color Suffix
TV105 = PVC Tubing 12 = 12 AWG C = 100' (30.5m) Leave Blank = Clear
B2. 6 = 6 AWG TL = 250' (76.2m) 20 = Black
Cable
Accessories 3 = 3 AWG D = 500' (152.4m)
1 = 1 AWG M = 1000' (304.8m)
0.38 = 3/8"
B3.
Stainless 0.50 = 1/2"
Steel Ties 0.75 = 3/4"
1.0 = 1"
C1.
Wiring Non-Shrink PVC Tubing
Duct
• Provides insulation and protection for lead wires, wire harness • Voltage rating: 300 V and 600 V
assemblies, soldered joints and components in electrical and • ASTM D-922 Grade CFR
C2. electronic equipment
Surface • MIL-I-631 Type F, Form U, Grade C- Class 1 Category 1
Raceway • All purpose flexible and non-shrinkable
• Material: Polyvinyl chloride (PVC)
• Resistant to heat and moisture
• UL oil resistant class 1 rating
• Flammability: Meets UL 224 VW-1
C3.
Abrasion
Protection

C4.
Cable
Management

Length Max. Inside Wall Std. Std.


D1. Per Reel Diameter Thickness
Terminals Nominal Max. Voltage Pkg. Ctn.
Part Number Color Size Ft. m In mm In mm Rating Qty. Qty.
TV105-12MY Clear 12 AWG 1000 304.8 0.089 2.26 0.016 0.41 300 V 1 2
D2. TV105-12M20Y Black 12 AWG 1000 304.8 0.089 2.26 0.016 0.41 300 V 1 2
Power
Connectors TV105-6MY Clear 6 AWG 1000 304.8 0.178 4.52 0.020 0.51 300 V 1 2
TV105-6M20Y Black 6 AWG 1000 304.8 0.178 4.52 0.020 0.51 300 V 1 2
TV105-3MY Clear 3 AWG 1000 304.8 0.249 6.32 0.020 0.51 300 V 1 2
D3.
Grounding TV105-3M20Y Black 3 AWG 1000 304.8 0.249 6.32 0.020 0.51 300 V 1 2
Connectors TV105-1MY Clear 1 AWG 1000 304.8 0.311 7.89 0.020 0.51 300 V 1 —
TV105-1M20Y Black 1 AWG 1000 304.8 0.311 7.89 0.020 0.51 300 V 1 —
E1. TV105-.38DY Clear 3/8 500 152.4 0.399 10.13 0.025 0.64 600 V 1 —
Labeling TV105-.38D20Y Black 3/8 500 152.4 0.399 10.13 0.025 0.64 600 V 1 —
Systems
TV105-.50DY Clear 1/2 500 152.4 0.524 13.30 0.025 0.64 600 V 1 —
TV105-.50D20Y Black 1/2 500 152.4 0.524 13.30 0.025 0.64 600 V 1 —
E2. TV105-.75TLY Clear 3/4 250 76.2 0.786 19.96 0.035 0.89 600 V 1 —
Labels TV105-.75TL20Y Black 3/4 250 76.2 0.786 19.96 0.035 0.89 600 V 1 —
TV105-1.0CY Clear 1 100 30.5 1.036 26.31 0.035 0.89 600 V 1 2
E3. TV105-1.0C20Y Black 1 100 30.5 1.036 26.31 0.035 0.89 600 V 1 2
Pre-Printed
& Write-On
Markers
Duct Seal – Sealing Compounds
• Seals irregular openings from air, dust, or water • Safe and easy to use, non-corrosive, non-toxic, no asbestos, will
E4. • Non-hardening sealant that adheres to metal, masonry, wood not stain or harm hands, and no unpleasant odor.
Permanent or plastic • Dielectric strength: 200 V/Mil, Min .030" thick
Identification
• Provides vibration dampening
E5.
Lockout/ Std.
Tagout Pkg.
& Safety
Solutions Part Number Description Qty.
DS1 Duct seal (sealing compound) 1 lb. package 1
F. DS5 Duct seal (sealing compound) 5 lb. package 1
Index

C3.18 Order number of pieces required, in multiples of Standard Package Quantity.


Data Sheet

HILTI CP 670
Firestop Coated Board System

The enclosed pages are taken from the


Hilti Firestop Systems Manual
Edition April 2011
Supported by additional standard details

For Material Safety data sheets


visit the technical library at www.hilti.co.uk/cfs

Hilti (Gt Britain) Ltd


TECHNICAL ADVISORY SERVICE
TELEPHONE 0161 886 1144

Quality Management System Certification

Standard: ISO 9001:2008


Issued by: The Swiss Association for Quality and Management Systems SQS.
Registration No: 12455 (The current certificate can be downloaded from www.hilti.co.uk)
Field of activity: Market Organisation.
Note: The certificate of Hilti (Gt. Britain) Ltd. is a sub-certificate to the master certificate of Hilti
Aktiengesellschaft,FL-9494 Schaan with the field of activity: Research, Development, Manufacturing, Sales
and Service.

Hilti (Gt. Britain) Limited, Telephone:


1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY 0800 886 100
Hilti Firestop Systems Hilti Firestop Systems

Firestop coated board system Technical Information


CP 670
Hilti CP 670 is an innovative system for fast, reliable and cost effective firestopping of wall and floor openings - especially large
ones. Tested to both BS476 Part 20 and EN 1366-3

Applications Technical data


„ Extended approvals for large diameter cables, dampered CP 670
penetrations and double board usage
Fire rating Up to 4 hours
„ Single cables, cable bundles, cable tray, air ducts and pipes
Base materials Concrete, Masonry, Drywall
„ Non combustible pipes (in conjunction with other products)
„ Large penetrations possible up to 5 metres high or with an Application temperature range 5°C - 40°C
unrestricted length Acoustics performance Up to 62dB
„ Detail for wall dampers available Density (coating) 1470 kg/m³
Colour White
Advantages
Skin forming time 7 hours
„ Pre-coated board (at 23°C/50% r.H) (CP 670 Coating)
„ Odourless and solvent free
„ Less prone to damage due to pliancy of the material and the
resilient elastic coating
„ Approved for a wide range of applications Maximum area of CP 670 Type B (Penetrations) in different
„ Fast tight seal, less sealant required for gap filling rated substrates. Estimated sound reduction values.
„ Tested for face-fixed applications Concrete (details also available for drywall)
For more standard details and technical information register
Substrate value Area of wall Area of CP Total area Required value online at the Hilti Firestop Design Centre at www.hilti.co.uk/cfs
Rw m2 670 m2 m2 Rw
35 8.8 0.2 9
40 8.0 1.0 9
45 7.6 1.4 9 35
50 7.5 1.5 9
55 7.5 1.5 9
40 8.95 .05 9
45 8.7 0.3 9 40 Installation instructions for CP 670 coated board system
50 8.6 0.4 9 Notice Note
55 8.6 0.4 9 • Before handling, read Material Safety Data Sheet and Firestop Sealant (refer to relevant BS reports for Instead of using a Hilti CP 670 Firestop board Hilti
45 8.99 .01 9 specific details).
product label for safe usage and health information. CP 670 Fire Safety Coating can be either sprayed or
50 8.9 0.1 9 45
• Instructions below are general guidelines Insert the mineral wool panel flush with the opening painted on the jobsite prior or during installation,
55 8.87 .13 9
50 9.0 0 9 50 edge. respectively in advance. To achieve the dry coating of
55 8.97 .03 9 4. Pack any larger gaps with loose mineral wool. 0.7 mm, a wet film thickness of ca. 1.1 mm is required.
55 9.0 0 9 55 Application of Fire Blocks Seal between cables with Hilti CP 606 Firestop Hilti CP 670 Fire Safety Coating can be used where
All calculations are based on DIN 4109 Supplement 1 - Sound control in buildings, design examples 1. Clean the opening. Do not pre-moisten opening Sealant (BS: respectively CP 611A). cutting has caused exposed mineral wool to appear.
and calculation procedure. 11 - Resulting sound insulation R’w, R, res, for a component made from surfaces. Cables and cable supporting structures Fill gaps with Hilti CP 606 Firestop Sealant (BS: In addition, the coating can be applied if mineral wool
elements with differing degrees of sound insulation, e.g. a wall with a door or window. must be dry andclean from dust, grease or oil, respectively CP 611A). is used to pack gaps.
and installed in compliance with local building and 5. Thoroughly stir Hilti CP 670 Fire Safety Coating
Ordering electrical standards. Apply Hilti CP 670 Fire Safety Coating to the cables Storage
2 Cut the Hilti CP 670 Firestop board to size. In case of and cable trays on all surfaces over the required
Order description Package Contents Package Quantity Item number • Store only in the original packaging in a location
services cut out required space.Coat cut edges with length. It can be applied using a brush, roller or protected from moisture and direct sunlight
Firestop board 4 x CP 670 firestop acoustic board 4 pc 00284225 Hilti CP 606 Firestop Sealant. airless spray gun (recommendation: a nozzle 0.029”
CP 670 (4) 3. Coat the surface of the opening with Hilti CP 606 diameter, spray angle 40°). To achieve the dry
coating of 0.7 mm, a wet film thickness of ca. 1.1
Firestop board 20 x CP 670 firestop acoustic board 20 pc 00284301 mm is required. Fasten installation plate (if required)
CP 670 (20)
Firestop board 40 x CP 670 firestop acoustic board 40 pc 00376024
CP 670 (40)
Firestop coating flexi coating (6kg) 1 pc 00376023
CP 670 6kg

1 2 3 4 5

 9LVLWWKH+LOWL)LUHVWRS'HVLJQ&HQWUH5HJLVWHUWRGD\DWZZZKLOWLFRXNFIV +LOWL2XWSHUIRUP2XWODVW 
Hilti Firestop Systems Hilti Firestop Systems

Firestop coated board system Technical Information


CP 670
Hilti CP 670 is an innovative system for fast, reliable and cost effective firestopping of wall and floor openings - especially large
ones. Tested to both BS476 Part 20 and EN 1366-3

Applications Technical data


„ Extended approvals for large diameter cables, dampered CP 670
penetrations and double board usage
Fire rating Up to 4 hours
„ Single cables, cable bundles, cable tray, air ducts and pipes
Base materials Concrete, Masonry, Drywall
„ Non combustible pipes (in conjunction with other products)
„ Large penetrations possible up to 5 metres high or with an Application temperature range 5°C - 40°C
unrestricted length Acoustics performance Up to 62dB
„ Detail for wall dampers available Density (coating) 1470 kg/m³
Colour White
Advantages
Skin forming time 7 hours
„ Pre-coated board (at 23°C/50% r.H) (CP 670 Coating)
„ Odourless and solvent free
„ Less prone to damage due to pliancy of the material and the
resilient elastic coating
„ Approved for a wide range of applications Maximum area of CP 670 Type B (Penetrations) in different
„ Fast tight seal, less sealant required for gap filling rated substrates. Estimated sound reduction values.
„ Tested for face-fixed applications Concrete (details also available for drywall)
For more standard details and technical information register
Substrate value Area of wall Area of CP Total area Required value online at the Hilti Firestop Design Centre at www.hilti.co.uk/cfs
Rw m2 670 m2 m2 Rw
35 8.8 0.2 9
40 8.0 1.0 9
45 7.6 1.4 9 35
50 7.5 1.5 9
55 7.5 1.5 9
40 8.95 .05 9
45 8.7 0.3 9 40 Installation instructions for CP 670 coated board system
50 8.6 0.4 9 Notice Note
55 8.6 0.4 9 • Before handling, read Material Safety Data Sheet and Firestop Sealant (refer to relevant BS reports for Instead of using a Hilti CP 670 Firestop board Hilti
45 8.99 .01 9 specific details).
product label for safe usage and health information. CP 670 Fire Safety Coating can be either sprayed or
50 8.9 0.1 9 45
• Instructions below are general guidelines Insert the mineral wool panel flush with the opening painted on the jobsite prior or during installation,
55 8.87 .13 9
50 9.0 0 9 50 edge. respectively in advance. To achieve the dry coating of
55 8.97 .03 9 4. Pack any larger gaps with loose mineral wool. 0.7 mm, a wet film thickness of ca. 1.1 mm is required.
55 9.0 0 9 55 Application of Fire Blocks Seal between cables with Hilti CP 606 Firestop Hilti CP 670 Fire Safety Coating can be used where
All calculations are based on DIN 4109 Supplement 1 - Sound control in buildings, design examples 1. Clean the opening. Do not pre-moisten opening Sealant (BS: respectively CP 611A). cutting has caused exposed mineral wool to appear.
and calculation procedure. 11 - Resulting sound insulation R’w, R, res, for a component made from surfaces. Cables and cable supporting structures Fill gaps with Hilti CP 606 Firestop Sealant (BS: In addition, the coating can be applied if mineral wool
elements with differing degrees of sound insulation, e.g. a wall with a door or window. must be dry andclean from dust, grease or oil, respectively CP 611A). is used to pack gaps.
and installed in compliance with local building and 5. Thoroughly stir Hilti CP 670 Fire Safety Coating
Ordering electrical standards. Apply Hilti CP 670 Fire Safety Coating to the cables Storage
2 Cut the Hilti CP 670 Firestop board to size. In case of and cable trays on all surfaces over the required
Order description Package Contents Package Quantity Item number • Store only in the original packaging in a location
services cut out required space.Coat cut edges with length. It can be applied using a brush, roller or protected from moisture and direct sunlight
Firestop board 4 x CP 670 firestop acoustic board 4 pc 00284225 Hilti CP 606 Firestop Sealant. airless spray gun (recommendation: a nozzle 0.029”
CP 670 (4) 3. Coat the surface of the opening with Hilti CP 606 diameter, spray angle 40°). To achieve the dry
coating of 0.7 mm, a wet film thickness of ca. 1.1
Firestop board 20 x CP 670 firestop acoustic board 20 pc 00284301 mm is required. Fasten installation plate (if required)
CP 670 (20)
Firestop board 40 x CP 670 firestop acoustic board 40 pc 00376024
CP 670 (40)
Firestop coating flexi coating (6kg) 1 pc 00376023
CP 670 6kg

1 2 3 4 5

 9LVLWWKH+LOWL)LUHVWRS'HVLJQ&HQWUH5HJLVWHUWRGD\DWZZZKLOWLFRXNFIV +LOWL2XWSHUIRUP2XWODVW 
Standard firestop detail

APPLICATION
Hilti CP 670 Firestop acoustic
board. Head of Wall application
Test Up to Approvals
Fire Integrity 120 minutes EN 1366-3
Insulation 120 minutes BS 476: Part 20
Air Tightness Head of Wall joint
Age Testing 30 years BS EN ISO 140-3

CP 606 at all Concrete soffit


batt edges

CP 670 Coated board

CP 606 at all
batt edges

Drywall partition

CP 670 coated batt must be installed in accordance with


manufacturer's guidelines, utilising CP 606 fire rated
acoustic mastic at all batt to batt and batt to substrate
junctions.

The above applications are not


exhaustive. For further details
please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

1.5.13 Drawn by A Brockett FS 098 Issue 02


Standard firestop detail

APPLICATION
Hilti CP 670 Firestop acoustic
board - Type A Horizontal detail
Test Up to Approvals
Fire Integrity 60 Minutes BS476 pt 20
Insulation 60 Minutes EN 1366-3 Mixed services
Acoustics 39 dB passing through
Age Testing 30 Years Solid floor

600 mm
Any Length

Max dia 89 mm, Mineral wool lagged


Max dia 168 mm Mineral wool
copper pipe (to provide the required T
lagged steel pipe (to provide
rating)
the required T rating) Cables max dia 78mm
/cable trays max 500mm
50 mm

CP 670 (Type A)
coated batt

CP 643N collar for PVC & PE pipes


between 20 mm - 110 mm dia.

CP 606 Intumescent mastic must be used at all batt edges in accordance with the installation guidelines.

The CP 643N collars should be secured to the underside of the batt using M8 threaded rod through the fixing hooks
and secured with oversized washers on the upper face of the batt. The CP 670 coated board should be installed
tightly around the service pipe.

All service items must be secured either side of the batt seal system.

1. The application limits on this detail are for guidance purposes only. For more detailed information on the full range of available test results please
contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS 476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's installation instructions, by competent, experienced installers using Hilti branded
products.

1.5.13 Drawn by A Brockett FS 099 Issue 02


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION
Hilti CP 670 Firestop acoustic
board - Type B Horizontal detail
Test Up to Approvals
Fire Integrity 60 Minutes BS476 pt 20
Insulation 60 Minutes EN 1366-3 Mixed services
Acoustics 52 dB passing through
Age Testing 30 Years Solid floor

1200 mm
Any Length

Max. dia. 89 mm, Mineral wool lagged


max dia. 168 copper pipe (to provide the required T
mm Mineral rating)
wool lagged
steel pipe (to Cables max. dia78mm
provide the /cable trays max
required T 500mm
rating)
100 mm

CP 670 (Type B)
coated batt

CP 643N collar for PVC & PE pipes CP 648 pipewrap for PVC & PE pipes
between 20 mm - 160 mm dia. between 20 mm - 160 mm dia
CP 606 Intumescent mastic must be used at all batt edges in accordance with the installation guidelines. All joints to
be staggered

The CP 643N collars should be secured to the underside of the batt using M8 threaded rod through the fixing hooks
and secured with oversized washers on the upper face of the batt. The CP 670 coated board should be installed
tightly around the service pipe.

All service items must be secured either side of the batt seal system.
1. The application limits on this detail are for guidance purposes only. For more detailed information on the full range of available test results please
contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS 476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's installation instructions, by competent, experienced installers using Hilti branded
products.

1.5.13 Drawn by A Brockett FS 100 Issue 03


Standard firestop detail

APPLICATION
Hilti CP 670 Firestop acoustic
board - Type B Horizontal detail (2hr)
Test Up to Approvals
Fire Integrity 120 Minutes (90 minutes-CP 648) EN 1366-3
Insulation 120 Minutes (90 minutes -CP 648) Mixed services
Acoustics 52 dB passing through
Age Testing 30 Years Solid floor

1000 mm
2000 mm

Max. dia. 89 mm Mineral wool lagged


max. dia. 168 mm Mineral copper pipe (to provide the required T
wool lagged steel pipe (to rating)
provide the required T Cables max dia.80mm
150 mm

rating) /cable trays max. 500mm


100 mm

150 mm CP 670 C
Coatback on each face of
cables/cable tray

CP 670C Coatback
CP 670 (Type B)
coated batt Alternative solution for
combustible pipes:

CP 648 Pipe Wrap for 20 -160


mm dia. PVC and HDPE
CP 644 collar for PVC & HDPE pipes pipes
NB: 90 minutes fire rating only
between 20 mm - 160 mm dia.
CP 606 Intumescent mastic must be used at all batt edges in accordance with the installation guidelines. All joints
between layers to be staggered.

The CP 644 collars should be secured to the underside of the batt using M8 threaded rod through the fixing hooks
and secured with oversized washers on the upper face of the batt. The CP 670 coated board should be installed
tightly around the service pipe.

All service items must be secured either side of the batt seal system.
1. The application limits on this detail are for guidance purposes only. For more detailed information on the full range of available test results please
contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS 476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's installation instructions, by competent, experienced installers using Hilti branded
products.

1.5.13 Drawn by A Brockett FS 101 Issue 03


Standard firestop detail

APPLICATION
Hilti CP 670 Firestop acoustic
board - Face Fix detail
Test Up to Approvals
Fire Integrity 120 minutes BS 476: Part 20
Insulation 120 minutes Mixed services
Air Tightness passing through
Age Testing 30 years Unlined Drywall
Max 1000 mm
CP 670 Coated Batt - Face fixed to
100 mm Drywall screws plasterboard with Drywall screws.
with oversized washers CP 606 Mastic should be used to coat any
exposed mineral wool at the batt edges

CP 606 to seal between

Max 1000 mm
service item and coated batt

Non combustible pipes Insulated or


uninsulated (Combustible insulation must
be cut back where it penetrates the batt)

100 mm
CP 606 to seal between
service item and coated batt

For fire performance of individual penetrants


consult data sheet DS 686 Issue 1
100 mm

CP 670 batt to be
bedded on CP 606
at the junction with
the Plasterboard.

For combustible pipes please refer to detail FS103

- CP 670 coated batt must be installed in accordance with manufacturer's guidelines, utilising CP 606 fire rated acoustic mastic at all batt to batt
and batt to substrate junctions. The batt should overlap the plasterboard by a minimum of 100 mm on all edges.
- CP 670 coated batt must be fixed back to the plasterboard partition utilising min 100 mm long drywall screws and oversized washers. The
fixings must be at nom 150 mm ctrs on the horizontal and 200 mm ctrs on vertical edges.
- Butt joints between coated batts are permitted provided that each section of batt is fixed on 3 sides. Joints within the batt should be staggered
from face to face such that no direct through gap exists between the two layers i.e. horizontal joints on one face and vertical joints on the other.
- All service items must be supported either side of the proposed seal system. The fire performance of the seal is only good as that of the
supporting construction and as such the structural adequacy of the partition must be guaranteed.
The above applications are not
exhaustive. For further details
please contact
1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

1.5.13 Drawn by A Brockett FS 102 Issue 03


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

Hilti CP 670 Firestop board - Face APPLICATION

Fix detail for plastic pipes with a


CP 645 Firesleve
Test Up to Approvals
Fire Integrity 120 minutes BS 476: Part 20
Insulation 120 minutes Plastic pipes
Air Tightness passing through
Age Testing 30 years Unlined Drywall
This application requires a formal engineering judgement. Please contact your local firestop specialist for further details.

100 mm Drywall screws CP 670 Coated Batt - Face fixed to


with oversized washers plasterboard with Drywall screws.
CP 606 Mastic should be used to coat any
exposed mineral wool at the batt edges

CP 606 mastic fillet


CP 645 Firesleeve

PVC, PP and ABS pipes up to


Min 25 mm 110 mm. Pipes must be secured
either side of the seal system

The max aperture should not exceed


100 mm

CP 670 batt to be bedded on CP 606 at


the junction with the Plasterboard. 1000 mm wide by 1000 mm high.

- CP 670 coated batt must be installed in accordance with manufacturer's guidelines, utilising CP 606 fire rated acoustic mastic at all batt to batt
and batt to substrate junctions. The batt should overlap the plasterboard by a minimum of 100 mm on all edges.
- CP 670 coated batt must be fixed back to the plasterboard partition utilising min 100 mm long drywall screws and oversized washers. The
fixings must be at nom 150 mm ctrs on the horizontal and 200 mm ctrs on vertical edges.
- Butt joints between coated batts are permitted provided that each section of batt is fixed on 3 sides. Joints within the batt should be staggered
from face to face such that no direct through gap exists between the two layers i.e. horizontal joints on one face and vertical joints on the other.
- All service items must be supported either side of the proposed seal system. The fire performance of the seal is only good as that of the
supporting construction.
- The CP 645 Firesleeve must be installed in accordance with the manufacturer's guidelines and ensuring that it projects by a minimum of 25 mm
on each face of the seal. The CP 670 coated batt must be installed tightly around the CP 645 such that the sleeve is secured under a slight
compression.
The above applications are not
exhaustive. For further details
please contact
1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.
Standard firestop detail

APPLICATION
CP 670 Type B Firestop seal to Fire
Damper
Test Up to Approvals
Fire Integrity 60 minutes BS 476 Pt 20
Insulation n/a EN 1366-3 Damper
Acoustics 52 dB installed within
Air Tightness √ Solid or partition wall
Age Testing 30 years

500 mm 500 mm
maximum maximum M10 drop rods anchored to
soffit with fire rated anchors
capable of providing load
1000 mm max.

resistance. Support in solid


wall to be in wall using
suitable anchors
Note: rods to be insulated for
drops to support greater than
1000 mm

Metal ductwork (max 1000 x1000


mm) c/w fire damper to be installed to
damper manufacturers instructions to
ensure weight of damper is CP 670 Type B
independently supported and
restrained and ductwork expansion Wall (concrete, masonry, partition, 100 mm
does not displace damper and CP minimum thickness) capable of providing 60
670 seal minutes minimum fire resistance

This detail is site specific and requires an engineering judgement.

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

Date: 22/7/10 Drawn By A Brockett FS 105 Iss 01


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION

Hilti CP 670 Fire Safety


Board-Type C Details (1 of 6)
Test Up to Approvals
Fire Integrity 4 hr BS476 pt 20
Insulation 3 hr EN 1366-3 Firestopping
Acoustics 52 dB large
Air Tightness � service openings
Age Testing 30 years
Frame spacing
Up to 5000
mm height
MM-C 30 Channel system
(Back to back )
1200 mm

A A
CP 670 Board
fastened to
channel frame
(Detail B-B)
1200 mm

B B

600 600 600 Any Width


mm mm mm

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

9.812 Drawn by A Brockett FS 118 Issue 04


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION

Hilti CP 670 Fire Safety


Board-Type C Details(2 of 6)
Test Up to Approvals
Fire Integrity 4 hr BS476 pt 20
Insulation 3 hr EN 1366-3 Firestopping
Acoustics 52 dB large
Air Tightness � service openings
Age Testing 30 years

DETAIL A-A

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

9.8.12 Drawn by A Brockett FS 118 Issue 04


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION

Hilti CP 670 Fire Safety


Board-Type C Details (3 of 6)
Test Up to Approvals
Fire Integrity 4 hr BS476 pt 20
Insulation 3 hr EN 1366-3 Firestopping
Acoustics 52 dB large
Air Tightness � service openings
Age Testing 30 years

DETAIL B-B

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

9.8.12 Drawn by A Brockett FS 118 Issue 04


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION

Hilti CP 670 Fire Safety


Board-Type C Details (4 of 6)
Test Up to Approvals
Fire Integrity 4 hr BS476 pt 20
Insulation 3 hr EN 1366-3 Firestopping
Acoustics 52 dB large
Air Tightness � service openings
Age Testing 30 years

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

9.8.12 Drawn by A Brockett FS 118 Issue 04


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION

Hilti CP 670 Fire Safety


Board-Type C Details (5 of 6)
Test Up to Approvals
Fire Integrity 4 hr BS476 pt 20
Insulation 3 hr EN 1366-3 Firestopping
Acoustics 52 dB large
Air Tightness � service openings
Age Testing 30 years

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

9.8.12 Drawn by A Brockett FS 118 Issue 04


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
Standard firestop detail

APPLICATION

Hilti CP 670 Fire Safety


Board-Type C Details (6 of 6)
Test Up to Approvals
Fire Integrity 4 hr BS476 pt 20
Insulation 3 hr* EN 1366-3 Firestopping
Acoustics 52 dB large
Air Tightness � service openings
Age Testing 30 years
* duct to be insulated

The above applications are


not exhaustive. For further
details please contact

1. The application limits on this detail are for guidance purposes only. For
more detailed information on the full range of available test results
please contact a Hilti Firestop Specialist on 0800 886100.
2. The product and application has been fire tested as a minimum to BS
476. It may have additional European and worldwide testing. Please
contact Hilti for further information.
3. All installations should be carried out in accordance with Hilti's
installation instructions, by competent, experienced installers using Hilti
branded products.

9.8.12 Drawn by A Brockett FS 118 Issue 04


Hilti (Gt. Britain) Limited | 1 Trafford Wharf Road | Trafford Park | Manchester M17 1BY Freephone: 0800 886 100 | Freefax: 0800 886 200 | www.hilti.co.uk
CP 670

CP 670 Type C schedule of materials


This schedule itemises enough material for the initial construction of a 25m² Type C seal in accordance with
Standard firestop detail FS118.
Notes; The quantities may be used pro rata as an indicator for other size of openings
Other materials may be required but exact items will depend on the size and type of penetrations and the
rating required. Please see below for possible additions.
Quantities are approximate

ITEM CODE QUANTITY COMMENTS

MM C 30 x 3m 418776 40 lengths
MM A 90 418757 150 Pre-assembled right angled
connector

M8 X 16 set screw 216446 200 For assembling back to


M8 nuts 216465 200 back channels
M8 washers 282850 200
CP 670 (40) 376024 2 PC (40 boards per PC)
CP 606 310638 200* approx.
CP 670 coating 376023 4 tubs approx.
Screws S-DS01B 4.2 x 386578 1500 no. approx. Attaching board to frame
70 (single) Washer under the head of
screw
M6 x 28mm washers 282860 1500 no. approx.
S-NSD 13L Drive socket (for 318364 1 (hex drive for 3 jaw chuck
fixing to substrate) or direct to SID 121-A
driver)
SW 13 Drive socket 423767 1 (1/2” drive for direct fitting
to SIW 121-A driver)
* Note that the number of pieces of CP 606 may need to be increased due to number and type of penetrants.

Fixing the MM-30 frame to the substrate will depend on the substrate itself

Substrate recommended type of fixing


Concrete HUS H 6 x 35 or HST M8/10
Brick/block HUS H 6 x 35
Steel M8 DX stud

Possible additions to schedule – check Hilti Product Catalogue for or contact Firestop Specialist for item numbers.

M8 threaded rod
M8 saddles for fixing rod holding pipe clamps etc.
M6 saddles for taking roofing bolts for fixing tray
M6 roofing bolts
Pipe rings for holding pipes integral to framed system
MM Channel bases

For ease of installation we recommend the use of;


SID or SIW impact screwdriver, Assembly of the frame
WSR 36-A reciprocating saw. Cutting materials to size
TE7A + drill bits, drilling for HUS or HST fixings for attaching to concrete and masonry substrates
DX 460, for fixing to steel components
Threaded Rod Cutter, cutting drop rods to support services.

Hilti (Gt. Britain) Limited, Telephone:


1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY 0800 886 100
Data Sheet
Sheet 1 of 3

DS 686 Iss 2

CP 670 Integrity and insulation tables

Type A
- Single 50 mm layer of pre coated CP 670 with services independently supported on either side of seal
- For use in apertures up to 2400 mm high by 1200 mm wide or 1200 mm high by 5000 mm wide
- Fire Resistance: Integrity & Insulation
(See Standard detail FS 047-05 Hilti CP670 Firestop acoustic board type A)
30 60 90 120 180 240
Int Ins Int Ins Int Ins Int Ins Int Ins Int Ins
Blank Seals      
Small Diameter Individual Cables (<20mm)     
Medium Diameter Individual Cables (21 to 40
   C 1
mm)
Large Diameter Individual Cables (41 to 75
    1
mm)
Small diameter bunched cables (<20 mm)     
Medium Diameter Bunched Cables (21 to 40
   C 1
mm)
Large Diameter bunched Cables (41 to 75
    1
mm)
Cable trays/ladders      
Trunking up to 250 x 250 mm*    2  2  2
Steel/cast iron pipes up to 250 mm diameter  2  2  2
PVC pipes up to 110 mm dia using CP 643  S  S  
PP,ABS Plastic Pipes Up to 110 mm dia CP645   
Copper pipes up to 108 mm diameter  2  2  2  2
PVC Pipes Up to 168 mm diameter CP645    
1 = requires CP 611A (See Standard detail FS080-02 Hilti CP611A High pressure intumescent sealant)
2 = Insulation ratings can be achieved on Steel & Copper pipes by using CP645 Fire Sleeves with a projection
of 500 mm or 25 mm from each face and taped to existing fire resistant pipe insulation(See Standard
detail “FS005-02 Hilti CP645 intumescent firesleeve”)
*= Inside of Trunking to be sealed with CP 651N cushions
C = Requires Coatback (Coat service items as required for either 100mm(90mins insulation) or 150mm
(120mins insulation value)on either side of the seal with CP670C fire safety coating.
S = surface mounted and fixed with M8 threaded rod nuts and washers
Insulation ratings can be achieved on trunking by using appropriate insulation
Ensure All services are adequately supported within 500mm of both faces of the seal See ”DS 0676 Iss 1
Fireseals and supports for Building Services”

Compiled: RBL Approved: Revised: ABrockett 26.2.13 Item No.

Hilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100
Data Sheet - sheet 2 of 3

DS 686 Iss 2

Type B
- Multi Layer CP 670 of 100 mm minimum overall Board thickness
- No internal framing.
- For use in apertures up to 1200 mm high by any length wide.
Fire Resistance: Integrity & Insulation
(See Standard detail FS 050-05 Hilti CP670 Firestop acoustic board type B)
30 60 90 120 180 240
Int Ins Int Ins Int Ins Int Ins Int Ins Ins Int
Blank Seals            

C C C C C C
Small Diameter Individual Cables (<20mm) C
Medium Diameter Individual Cables (21 to 40
C C C C C C C
mm)
Large Diameter Individual Cables (41 to 75
C C C C C C C
mm)
Small diameter bunched cables (<20 mm) C C C C C C C
Medium Diameter Bunched Cables (21 to 40 
C C C C C C
mm) C

C C C C C C
Cable trays/ladders C
Trunking up to 250 x 250 mm* C C C C C C C
Duct and Damper up to 1000 mm Square
Steel/cast iron pipes up to 200 mm diameter
          
(insulated)
UPVC Pipe up to 110 mm With CP643      2  2
Copper pipes up to 108 mm diameter    

1 = requires CP 611A (See Standard detail FS080-02 Hilti CP611A High pressure intumescent sealant)
2 = Surface mounted only

C = Requires Coatback (Coat service items as required for either 100mm(90mins insulation) or 150mm (120mins
insulation value) on either side of the seal with CP670C fire safety coating.
*= Inside of Trunking to be sealed with CP 651N cushions
Ensure All services are adequately supported within 500mm of both faces of the seal See ”DS 0676 Iss 1 Fireseals
and supports for Building Services”

Hilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100
Data Sheet - sheet 3 of 3

DS 686 Iss 2

Type C
- Multi Layer CP 670 of 100 mm minimum overall Board thickness
- Internal profiled steel support frame of MMC30
- For use in apertures up to 5000 mm high by any length wide.
Fire Resistance: Integrity & Insulation
(See Standard detail FS118-02)
30 60 90 120 180 240
Int Ins Int Ins Int Ins Int Ins Int Ins Int Ins
Blank Seals         
Small Diameter Individual Cables (<20mm)        C 
Medium Diameter Individual Cables (21 to 40
mm)        C 
Large Diameter Individual Cables (41 to 75
mm)         
Small diameter bunched cables (<20 mm)        C 
Medium Diameter Bunched Cables (21 to 40
mm)        C 
Cable trays/ladders         
Trunking up to 250 x 250 mm*       
Duct and Damper up to 1000 mm Square       
Steel/cast iron pipes up to 200 mm diameter       
UPVC Pipe up to 110 mm With CP643      2  2
Copper pipes up to 108 mm diameter    

1 = requires CP 611A
2 = Surface mounted only
*= Inside of Trunking to be sealed with CP 651N cushions
C= = Requires Coatback (Coat service items 150mm (120mins insulation value) on either side of the seal with
CP670C fire safety coating

Ensure All services are adequately supported within 500mm of both faces of the seal See ”DS 0676 Iss 1
Fireseals and supports for Building Services

HILTI TECHNICAL ADVISORY SERVICE


TELEPHONE 0161 886 1144

IMPORTANT NOTES

1. The information and recommendations given herein are believed to be correct at the time of writing. The
data has been obtained from tests done under laboratory, or other controlled, conditions and it is the
users’ responsibility to use the data given in the light of conditions on site and taking account of the
intended use of the products concerned. Whilst Hilti (Gt. Britain) Limited can give general guidance and
advice, the nature of Hilti products means that the ultimate responsibility for selecting the correct product
for a particular application must lie with the customer.
2. All products must be used, handled and applied in accordance with current instructions for use published
by Hilti (Gt. Britain) Limited.
3. All products are supplied, and advice given, subject to Hilti (Gt. Britain) Limited terms of business.
4. Hilti’s policy is one of continuous development. We therefore reserve the right to alter specifications etc.
without notice.
5. Construction materials and conditions vary on different sites. If it is suspected that the base material has
insufficient strength to achieve a suitable fixing, contact the Hilti Technical Advisory Service.

Hilti (Gt. Britain) Limited, 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY Telephone: 0800 886 100
CP 670

Additional Properties of CP 670 Firestop Coated Board System

Property Test regime Notes

Fire BS 476 - 20 
BS EN 1366-3 
Certifire 663

Acoustic EN ISO 20 140-10: 1992 Type A 39 dB


EN ISO 20 140-10: 1992 Type B&C 52 dB
BS EN ISO 140-3:1995 Head of wall 62 dB
ISO 140-9 & BS EN ISO 10848 Dn,f,w, 46 dB
ISO 140-9 & BS EN ISO 10848 Dn,f,w, 50 dB

Ageing DIBT 
DAfSTB 
Fire test after ageing 

Air sealing DIN 1026 


Pressure difference 50Pa
Pressure difference 200Pa 

Electrical Surface resistance 


resistance Volume resistivity 
Insulator Yes

Water Rain Resistance N.R


resistance Mold and Mildew resistance ISO 846 Class 0-1
Water tightness UL 1479 

VOC LEED 2009 LEED 3.0 38 g/l



Chemical Contact Hilti Technical Advisory Service with details of type, concentration, duration and ambient
Resistance temperature of exposure conditions

N.R Not relevant


 Meets standard

Hilti (Gt. Britain) Limited, Telephone:


1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY 0800 886 100
CP 670

CP 670 Firestop Coated Board System - BREEAM criteria

BREEAM Section

No power tools required for


installation (no energy source
Management construction site required) 
impact Dust free installation 
Saves water during application
No water pollution 
Low VOC* (air quality) 
No ozone depletion potential
(ODP) 
Health and wellbeing Low global warming potential
(GWP) 
Smoke and gas tightness 
Noise reduction 
Air tightness 
Energy
Avoidance of air infiltration 
Product Carbon Footprint or LCA
Materials Data 
Thermal insulation 
Recycling of packaging 
Waste
Reuse of materials 
Re-penetration in existing opening
(No waste) NA

Product contributes to Green


Building under this clause

Not applicable for this product NA
Product makes No contribution to
green Building under this clause


Hilti (Gt. Britain) Limited, Telephone:


1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY 0800 886 100
Product information

FIRESTOP FOAM CP 620


Product description
• Rigid and fast-curing firestop foam with excellent water resistance to help
create a fire, smoke and moisture barrier around cable and mixed penetrations

Applications for use


• Concrete, drywall and masonry
• Multiple and mixed penetrations
• Metal pipes, single cables, cable bundles and cable trays
• Suitable for irregular and difficult-to-reach openings
• Sealing small to medium size openings
• Where cables, steel, copper, cast iorn or plastic pipes all pass through the
same opening

Advantages
• Adheres to concrete, drywall and masonry
• Approval for virtually any transit type — cables, trays, conduits and pipes (metal
and plastic)
• Up to 6 times expansion
• Suitable for complex and difficult-to-reach applications — single-sided
installation possible and no reinforcing material needed
• Cures within 60 seconds
• Mold, mildew, water and vapor resistant
• Future-proof — re-penetrable to allow future cable capacity increases
• Optimal smoke tightness according to DIN EN 1026 and ASTM E 283-04

Installation instructions
• See Hilti literature or third-party listings for complete application and installation
details

Sales pack Item


Technical Data Order designation
quantity number

Chemical basis Two component polyurethane CP 620 Firestop Foam 12 338725

Color Red CP 620 + Dispenser 12 371883

Recommended product application 50° to 86°F (10° to 30°C)


temperature

Recommended substrate temperature 32° to 104°F (0° to 40°C)

Storage and transportation temperature range 41° to 77°F (5° to 25°C)

Temperature resistance range -22 to 212°F (-30° to 100°C) FM


Mold and mildew Smoke $33529('
Expansion ratio 1:1.5 resistant )RU3HQHWUDWLRQ)LUH6WRSV
&RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH
Mold and mildew performance Class 0 (ASTM G21-96)

Tested in accordance with UL 1479, ASTM E814, CAN/ULC-S115

Surface burning characteristics Flame Spread 0


(ASTM E84) Smoke Development 15 Accessories:
• Foam Dispenser DSC
Minimum curing time ready to cut 3 min • Mixer CP 620-M

LEED VOC 1.3 g/L

Volume per cartridge & foam yield (up to) 300ml & 116 in³

Acoustics performance 50 (relates to specific construction) ASTM E90

Shelf Life 9 months


DBS • 03/20

Expansion tempature) 482°F (250°C) FILL, VOID OR CAVITY MATERIALS


CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
FOR USE IN TROUGH-PENETRATION
FIRESTOP SYSTEMS
Hilti Firestop
R

SEE UL FIRE RESISTANCE DIRECTORY


Saving lives 66Y7

through innovation
and education
Product information

FLEXIBLE FIRESTOP SEALANT CP 606


Product description
• An acrylic based firestop sealant that provides movement capability in fire rated
joints and seals through-penetrations applications
Product features
• Silicone free • Easy clean up with water
• Halogen, asbestos and solvent free • Single component systems available
• Paintable • Meets LEED™ requirements for
• Tested up to 33% movement with 500 indoor environmental quality credit
cycles in accordance to UL 2079 and • 4.1 Low Emitting Materials, Sealants
ASTM 1966 and Adhesives and 4.2 Paints and
• Smoke and fume resistant Coatings
Areas of application
• Sealing construction/expansion joints • Cable bundles
• Top-of-wall joints • HVAC penetrations
• Metal pipes
For use with
• Various base materials such as masonry, concrete, gypsum, etc.
• Wall and floor assemblies rated up to 3 hours
• Not for use with CPVC
Examples
• Where a gypsum wall assembly meets the underside of a metal or concrete deck
• Sealing expansion joints to impede the passage of fire, smoke and toxic fumes
• Sealing around HVAC penetrations through fire-rated assemblies
Installation instructions
• See Hilti literature or third-party listings for complete application and installation
details

Technical data*
Chemical basis Water-based acrylic dispersion
Color Available in red, white and gray
Density 99.9 lb/ft³
Application temperature 35°F to 104°F (1.5°C to 40°C)
Storage temperature 35°F to 95°F (1.5°C to 35°C)
Temperature resistance -22°F to 176°F (-30°C to 80°C)
Shelf life 24 months
Tack free time 23mins (ventilated at 77°F, 80% rel. humidity) FILL, VOID OR CAVITY MATERIAL
FOR USE IN THROUGH-PENETRATION
Skin-forming time Approx. 15 min FIRESTOP SYSTEMS AND
Curing time Approx. 3 mm / 3 days JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
Average volume shrinkage (ASTM C1241) 22% 66Y7
Movement capability Up to 33%
Mold & mildew Class 0 (ASTM G21-96)
Electrical resistance Yes
LEED Compliant Yes (CDPH v1.2-2017)
LEED VOC 63 g/L
Intumescent No
Seismic resistant Yes
Water tightness Yes
Temperature resistance –22°F to 176°F (–30°C to 80°C)
Surface burning characteristics Flame Spread: 10
(ASTM E 84-96) Smoke Development: 0
Surface burning characteristics Flame Spread: 14
(CAN/ULC-S102) Smoke Developed: 4
California State Fire Marshall Approvals Yes (pens & joints)
City of New York approval Yes (CP606 MEA 100-99-MV6)
Air leakage (UL 2079 L-Rating) L-Rating at Ambient = Less than 1 CFM / Lin Ft.
L-Rating at 400%F = Less than 1 CFM / Lin Ft.
Sound transmission classification 56
(ASTM E 90-99) (Relates to specific construction)
DBS • 03/22

Tested in accordance with UL 2079, ASTM E 814, ASTM E 1966, ASTM E 84,
UL 1479, ASTM G21, ASTM C1241, CAN/ULC-S115
*At 73°F (23°C) and 50% relative humidity

Hilti Firestop
Saving lives
through innovation
and education
Strut Channel System

Single
Strut is used in various industries as light
structural support for tray systems and other
mechanical components. Metal Framing Channels
are accurately and carefully cold-formed to size

Channel from low carbon strip steel.

No. PART NUMBER LENGTH ( M ) WEIGHT

1 P-SUC-3-H 3 8.25 Kg
2 P-SUC-6-H 6 16.5 Kg

Material: Finishing:
- Sheet Steel - Hot Dipped Galvanised (HDG) - Powder Coating
- Paint - Electro galvanize / zinc plating, etc
STEEL
CITY
Specification
HDG. Conduit Fitting

E.M.T. CONNECTOR

Ø D

Application : Use to connect EMT conduit to any outlet boxes.

Features : Strong and easy installations.

Material : Mild steel 1.6 mm. ( Size 1/2" ~ 1" )

Mild steel 2.0 mm. ( Size 1-1/4" ~ 2" )

Reference Standard : ANSI/NFPA 70

Standard Finish : Hot-Dip Galvanized

Dimension (mm.) Tighten Screw Weight


Cat.,No. SIZE
T ØD L Size Qty. (g.)
H-MEN11 1/2" 9 18 31 3/16" x 3/8" 1 30
H-MEN12 3/4" 10 24 35 3/16" x 3/8" 1 44
H-MEN13 1" 12 30 42 3/16" x 3/8" 1 63
H-MEN14 1-1/4" 14 39 53 1/4" x 1/2" 2 124
H-MEN15 1-1/2" 15 44.5 59 1/4" x 1/2" 2 165
H-MEN16 2" 16 56 71 1/4" x 1/2" 2 234

Cat.,No. Cat.,No.
H-MEN11~MEN13 H-MEN14~H-MEN16
STEEL
CITY
Specification
HDG. Conduit Fitting

E.M.T. COUPLING

ØD

Application : Use to connect EMT conduit to EMT conduit.

Features : Strong and easy installations.

Material : Mild steel 1.6 mm. ( Size 1/2" ~ 1" )

Mild steel 2.0 mm. ( Size 1-1/4" ~ 2" )

Reference Standard : ANSI/NFPA 70

Standard Finish : Hot-Dip Galvanized

Dimension (mm.) Tighten Screw Weight


Cat.,No. SIZE
ØD L Size Qty. (g.)
H-MEP11 1/2" 18 35 3/16" x 3/8" 1 31
H-MEP12 3/4" 24 45 3/16" x 3/8" 1 44
H-MEP13 1" 30 50 3/16" x 3/8" 1 67
H-MEP14 1-1/4" 39 64 1/4" x 1/2" 2 125
H-MEP15 1-1/2" 44.5 72 1/4" x 1/2" 2 163
H-MEP16 2" 56 84 1/4" x 1/2" 2 244

Cat.,No. Cat.,No.
H-MEP11~H-MEP13 H-MEP14~H-MEP16
IP RATING COLOUR SIZE
IP65 WHITE M25

40.0
34.3
CABLE ANCHORAGE
7 - 13 © 2013 Essentra Components. All rights reserved.
FOR CABLE 25.5 Registered in England, Company No. 547495.
Registered Office: Avebury House,
201-249 Avebury Boulevard, Milton Keynes, MK9 1AU

Condition of Sale can be found on our website: essentra.com.

Essentra Components does not warrant that the files will be


error free and may create new versions ("Upgrades") at any
time, which may correct such errors. Essentra Components
has no obligation to notify you of such upgrades. Any
upgraded file will be published to the website, when it
becomes available.

You are not permitted to load any of the files on to a network


Suitable Panel server for the purposes of distribution to one or more other
computer(s) on that network or to effect such distribution.
Thickness 2 - 5 Essentra Components shall not be liable for any loss or
damage whatsoever or however caused, arising directly or
indirectly from the use of the files.

UNLESS OTHERWISE STATED


ALL DIMENSIONS IN mm DO NOT SCALE
LINEAR TOLERANCE THIRD ANGLE PROJECTION
SIZE (0) (0.0) (0.00)
0-10mm ±0.5 ±0.15 ±0.10
>10-30 ±0.5 ±0.20 ±0.15
5.5

>30-50 ±0.5 ±0.30 ±0.20


>50-100 ±0.8 ±0.50 ±0.25 ANGULAR TOLERANCE ±0.5 DEGREES
>100-200 ±1.5 ±0.80 ±0.40 UNSPECIFIED RADII 0.25mm
>200-300 ±2.0 ±1.20 ±0.80
20
17

DRAFT ANGLE 0.5 DEGREES


>300-500 ±3.0 ±2.00 ±1.00 DIMENSIONS IN BRACKETS [ ] ARE
>500 ±5.0 ±3.00 ±1.50 IN INCHES FOR REFERENCE ONLY
ORG. SCALE: CREATE DATE:
1.5:1 12/10/2020
MATERIAL:
TPE
Part ID: Project:
5 1664671 4007750-2
TITLE:
CABLE ANCHORAGE M25

SHEET
DWG. No.
1 of 1
APPROVED - UNCONTROLLED 1664671 ISSUE
1
Saddle Application:
To support and securely fasten rigidmetal conduit

Clamp
to the supporting surface. saddle clamps present
a dependable cable & pipe conduit management
solution. With a screw hole for affixing to almost
any surface, these versatile saddle clamps can hold
pipes and cables in place securely.

FOR D W T A L Ø
PART No. MATERIAL FINISHING.
CONDUIT SIZE (mm) (mm) (mm) (mm) (mm) (mm)

CCA-10-H STEEL 1/2” 21,3 ± 0,4 ± 20 1,5 20 65 5 HDG


CCA-11-H STEEL 3/4” 26,7 ± 0,4 ± 20 1,5 22 75 5 HDG
CCA-12-H STEEL 1” 33,4 ± 0,4 ± 25 2,0 25 90 5,3 HDG
CCA-13-H STEEL 1 - 1/4” 42,2 ± 0,4 ± 25 2,0 26 100 5,5 HDG
CCA-14-H STEEL 1 - 1/2” 48,3 ± 0,4 ± 25 2,0 28 110 5,5 HDG
CCA-15-H STEEL 2” 60,3 ± 0,4 ± 25 2,0 30 125 5,5 HDG
CCA-16-H STEEL 2 - 1/2” 73,0 ± 0,4 ± 30 2,5 35 150 6,5 HDG
CCA-17-H STEEL 3” 88,9 ± 0,4 ± 35 2,5 35 165 6,5 HDG
CCA-18-H STEEL 4” 114,3 ± 00,4 ± 35 2,5 40 200 6,5 HDG

Material: Finishing:
- Steel - Hot Dipped Galvanized (HDG)
- Stainless Steel ( SS 304 & SS 316 ) - Electro Galvanized
- Natural