MABUHAY!!! Thank you for choosing Leichtbric AAC Blocks for your project in the Philippines.
In this product guide, we use the terms Leichtbric, Autoclaved Aerated Concrete (AAC) and
Autoclaved Lightweight Concrete (ALC) interchangeably to define and describe the Product and its
general specification.
Leichtbric is made of German technology from Wehrhahn GmbH. Founded in 2005 Leichtbric is the
oldest and most established brand in Indonesia, Singapore and Malaysia, with an output capacity of
30,000m2 per day. We have exported over 4 million square meter to the regional countries.
Amongst its many features and general product specifications, Leichtbric can be supplied in several
dimensions and density classes. Leichtbric is tested and certified to relevant Standards called out by
mandatory Code of Practice and Common Industry practices. Please verify the product specifications
against your requirements to determine the suitability of Leichtbric for your intended applications.
We also provide Project References and technical support on applications and recommended use.
Method Statement is found in our Installation Guide, and is made available upon request.
Fire Rating
Up to 240 minutes @ 100 mm thickness bare wall
built up
Fire Safety
Noise Reduction
Fast Built Up
Environmentally Friendly
Lightweight Density
PRODUCT SPECIFICATION
Standard Density, S3 Class High Density, S5 Class Ultra Density, S7 Class
Test Description Test Standard
S3 (D480) S5 (D600) S7 (D650)
Dry Density (kg /m3) (BS EN 772-13) > 500 > 600 > 650
(BS EN 772-1) /
Compressive Strength (N/mm2) > 3.0 > 5.0 > 6.5
(ASTM C1693)
Drying Shrinkage (mm/m) (BS EN 680) 0.97 0.90 *** Ultra Density AAC
(S7 Density) @ is
Flexural Strength (N/mm2) (BS EN 1351) > 0.5 > 1.0 customed made for
specific projects that
Thermal Conductivity (W/m.k) (ASTM C518) 0.18 0.22 require superior
sound insulation, and
Fire Rating (BS 476 22) 4H 4H better lateral
strength. Please refer
Severe Duty
to test reports.
Pull Out - Pass
Strength & Robustness (SS492) Pull Down - Pass
Wash Basin - Up to 1500N
Cabinets - Up to 4000N
Recommended Use: For all typical applications For better STC >42-45 For better STC >48-50
REGULAR BLOCKS
INTERLOCKING BLOCKS
Remove all excess Thin Bed Adhesive. Ensure any gap found
between Blocks to be filled with Thin Bed Adhesive. Allow at least 3
days for built up AAC Wall to properly set before applying secondary
scope of works (plastering or M&E).
***Notes : Detailed Method Statement is found in our Installation Guide. Available upon request.
Typical Wall Built Up And Applications
AAC wall in wet area with Typical AAC wall using jumbo Typical AAC wall using regular
waterproofing and services size block in dry area. blocks and jumbo blocks,
pipes. external and common areas.
AAC wall bare wall finish with Skim Coat Finish 3-4 mm.
door opening. Trade Demonstration to
Government Consultants.
Download for
Remarks: * available only in hard copy
Softcopy.