You are on page 1of 1

38 ®

P8 Metal Pump
FLOW RATE TO 156 GPM (590.5 LPM)
MAXIMUM OPERATING PRESSURE = 125 PSI (8.6 BAR)

Specifications
WETTED HOUSINGS (Water Chambers and Manifolds)
MATERIAL SHIP WT. MATERIAL SHIP WT.
Aluminum 70 lbs. (31.8 kg.) Cast Iron 104 lbs. (47.1 kg.)
316 S.S. 112 lbs. (51.0 kg.) Hastelloy 114 lbs. (51.7 kg.)

NON-WETTED HOUSINGS
DESCRIPTION MATERIAL
Center Block Polypropylene

Air Chambers Aluminum

Air Valve Polypropylene

MAXIMUM SUCTION LIFT CAPABILITY


DRY LIFT
23' (7.0 m)
The above figure represents the rubber-fitted pump capability.

MAXIMUM DIAMETER SOLIDS


1
⁄4" (6.35 mm) Diameter

ELASTOMER OPTIONS
MATERIAL TEMPERATURE LIMITS
Polyurethane +10 (–12.2) to +150 ( 65.6) F° (C°)
Neoprene 0 (–17.8) to +200 ( 93.3) F° (C°)
Buna-N® +10 (–12.2) to +180 ( 82.2) F° (C°)
Nordel® –60 (–51.1) to +280 (137.8) F° (C°)
Viton® –40 (–40.0) to +350 (176.7) F° (C°)
Saniflex™ –20 (–28.9) to +220 (104.4) F° (C°)
2" FNPT Discharge P Teflon® PTFE +40 ( 4.4) to +220 (104.4) F° (C°)
Wil-Flex™ –40 (–40.0) to +225 (107.2) F° (C°)
K L
RUBBER-FITTED P8 METAL PUMP
F - S.S., C.I., Hast.
G - Alum.

1/2" FNPT BAR FEET PSIG


M 300
Air Inlet N (20) [34]
8 120
AIR CONSUMPTION
D Footed Base for Stainless Steel 250 (40) [68] 3
(SCFM) [Nm /h]
C & Hastelloy Models 7 100 (60) [102]
X 6 200 (80) [136]
E 80
B 5
T 150 (100) [170]
U 4 60
A 3 100
2" FNPT Inlet V 40
W 2
50 20
Base for Aluminum Screen Model 1
DIMENSIONS – P8 METAL
F - S.S., C.I., Hast. Water GPM 20 40 60 80 100 120 140 160
ITEM STANDARD METRIC Flowrates [LPM] [76] [151] [227] [303] [378] [454] [530] [606]
G - Alum. (inch) (mm)
A 15 29/32 404.0
B 1 7/8 47.6
C 24 3/4 628.7 TEFLON®-FITTED P8 METAL PUMP
3/4" FNPT D 26 11/32 669.2
Air Exhaust BAR FEET PSIG
E 14 355.6 300
F 2 1/4 57.2 120 (20) [34]
G 2 7/16 61.7 8 (40) [68] AIR CONSUMPTION
H 13 21/32 346.9 250 3
(SCFM) [Nm /h]
7 (60) [102]
J 13 1/2 342.9 100
H (80) [136]
K 9 1/32 229.4 6 200
L 10 254.0 80 (100) [170]
M 10 1/16 255.6 5
N 12 11/32 313.5 150 (120) [204]
4 60
J P 9/16 14.3
R 2 1/2 63.5 3 100 40
S 2 1/32 51.6
T 11 3/32 281.8 2
BSP threads available for 50 20
U 2 11/32 59.5 1
liquid inlet and discharge.
V 11 1/32 280.2
Refer to the EOM manual for TPE and W 15 7/32 386.6
Ultra-Flex™ performance curves. X Ø9/16 Ø14.3 Water GPM 20 40 60 80 100 120 140 160
Flowrates [LPM] [76] [151] [227] [303] [378] [454] [530] [606]

© Copyright 2000, Wilden Pump & Engineering Company


22069 Van Buren St. • Grand Terrace, CA 92313-5607 • Telephone 909-422-1730 • Fax 909-783-3440 • www.wildenpump.com