Pipe Technical & Test Data
GRP Pipe ND900 - PN2 - SN30000 - Standard Mortar Core Structure
Client: ART WONDER TECHNICAL WORKS
Project: SAUDI ARABIA GRP PIPE PROJECT
1 ERROR FOUND
Page 1/2
Nominal Diameter 900 mm
Design Pressure Class 2.0 bar
Pressure Class (actual) 7.2 bar
Design Stiffness Class 30000 Pa
Stiffness Class (Specific Stiffness at 5.0% deflection) 30000 Pa

Dimensions and Weight


International Unified Spigot OD Series
Outer Diameter @ machined spigot end 924.0 mm ±0.5
Tolerances on OD according to AWWA +1.0 -2.6 mm
Grinding thickness 0.1 mm
Pipe Outer Diameter (outside machined spigot end) 924.2 mm ±0.5
Pipe Inner Diameter 869.8 mm ±0.5
Nominal pipe wall thickness = average pipe wall thickness 27.22 mm ±0.25
Minimumum wall thickness at any point (-12.5% according to AWWA) 23.82 mm
Minimumum average wall thickness @ machined spigot end 26.97 mm
Minumum tolerances on thickness are acceptable if all other requirements
(stiffness, pressure class, hoop/axial strength) are fulfilled.
Inner Liner Thickness — 1 C glass veil — 90% of resin by weight 0.30 mm
Intermediate Chop Glass Liner Thickness — 70% of resin 0.70 mm
Mechanical wall thickness 25.97 mm
Internal skin 0.94 mm
Mortar Core 24.09 mm
Outer Skin 0.94 mm
Hoop Roving content in the mechanical wall 6.07 % by weight
Chop Roving content in the mechanical wall 5.80 % by weight
Resin content in the mechanical wall 27.85 % by weight
Sand content in the mechanical wall 60.27 % by weight
External Chop Glass Layer Thickness — 70% of resin 0.00 mm
Outer Liner Thickness - 1 Polyester veil — 90% of resin 0.25 mm
Pipe wall weight 149.13 kg/m

Resins
- for the Internal Liner: Isophtalic
- for the Structural Wall: Isophtalic
Resin system dereating - 25%

Raw Material per square meter of pipe wall Inner Skin Core Outer Skin
Resin 484 13,302 484 g/m2
Chopped Glass 298 2,375 298 g/m2
Hoop Glass 1,080 950 1,080 g/m2
Sand - 30,879 - g/m2

CFW Pipe Design UNIT5 Vem S.p.A. © 9/10/2022


SULAIMAN AL-QUADBI CO. FOR GRP & PLASTIC PRODUCTS
Pipe Technical & Test Data
GRP Pipe ND900 - PN2 - SN30000 - Standard Mortar Core Structure
Client: ART WONDER TECHNICAL WORKS
Project: SAUDI ARABIA GRP PIPE PROJECT
1 ERROR FOUND
Pag.2/2
Mechanical Characteriestics
Hoop Tensile Modulus (mechanical wall) 7,910 MPa
Hoop Tensile Modulus (total wall) 7,670 MPa
Hoop Flexural Elastic Modulus (total wall) 14,000 MPa
Axial Tensile Modulus 4,620 MPa
Stress @ 50 years (HDB) for VEM Std. Resin System 30 MPa
Service factor for resin type 0.75 -
Hoop Stress @ 50 years (HDB) for Used Resin System 23 MPa
Hoop Strain @ 50 years (HDB) for Used Resin System 0.28% (for initial hoop modulus)
Design Factor (factor of safety) 1.80 -
Service factor 0.56 -
Design Stress at Nominal Pressure 13 MPa
Design Strain at Nominal Pressure 0.16%

Ultimate Short Term Hoop Tensile Strength (1)


- required by the Standard Specifications (2) 359.3 N/mm 4.0 x
- total load for a pipe ring (2x15 mm) or plate (30 mm) 1.1 ton
- expected in the tensile test 1611.3 N/mm 17.9 x
- total load for a pipe ring (2x15 mm) or plate (30 mm) 4.8 ton
Ultimate Short Term Axial Tensile Strength
- required by the Standard Specifications (3) 150.0 N/mm
- expected in the tensile test 757.2 N/mm

Stiffness Data
Design Specific Stiffness (Specific Stiffness at 5.0% deflection) 30,000 Pa
Actual Specific Stiffness (Specific Stiffness at 5.0% deflection) 30,000 Pa
Actual Pipe Stiffnes AWWA (F/Dy for unit length) at 5.0% deflection 1,509,416 Pa
in US units 218.9 psi
Actual Initial Specific Stiffness ISO (at 0 % defection) 32,016 Pa
Level A Deflection (referred to 5% deflection pipe stiffness) 6.2 %
Level B Deflection (referred to 5% deflection pipe stiffness) 10.4 %
Expected Load for specimen width -> ISO ASTM
ISO = fixed width 300 mm; ASTM = max(300mm;0.2 x DN) 300 300 mm
Expected load at 3% deflection 13,385 13,385 N
Expected load at 5% deflection 21,747 21,747 N
Expected load at Level A deflection 26,705 26,705 N
Expected load at Level B deflection 42,329 42,329 N
Expected load at 30% deflection 99,264 99,264 N

HydroTest Data
Circumference elongation at 1x PN 1.3 mm
Circumference elongation at 2x PN 2.8 mm
End load on hydrotest machine at 1x PN 134 kN
End load on hydrotest machine at 2x PN 268 kN
Initial internal volume (12 m pipe length) 7,129.6 lt
Volume increase at 1xPN (12 m pipe length) 6.5 lt
Volume increase at 2xPN (12 m pipe length) 14.4 lt
1 ERROR FOUND
(1) To be tested at Split Disk Test or Mechanical Tensile Test
(2) AWWA or ASTM or ISO = Hoop Load at 4x PN
(3) AWWA or ASTM or ISO Standard; interpolated and merged value

CFW Pipe Design UNIT5 Vem S.p.A. © 9/10/2022