You are on page 1of 4

PROCUREMENT OF PORTABLE INDUSTRIAL X-RAY MACHINE

(01 LINE ITEMS)

(AS PER FOLLOWING SPECIFICATIONS)

Part No Description U/I Qty Req

Portable Industrial
MG 161L Ea 01
X-Ray Machine
TECHNICAL SPECIFICATIONS REQUIRED FOR PORTABLE INDUSTRIAL
X-RAY MACHINE MG 161L (or equivalent)
Components
Specifications Compliance/ Non
Compliance
Operational / 100KV to 200KV (2000W max
5 KV to 200 KV (1600W @ 5mA)
Power Rating
max. 10 mA) or equivalent
specification
Current Range 0.5 MA to 10 MA (0.1 mA  Preset 3 mA to 5 mA (0.1mA
interval) interval)
Up to 10 min (Adjustable in Continuous operation time is
Time
seconds from 1 sec to 10 adjustable from 0.1 to 30min
minutes) or equivalent
Tube Head Directional metal ceramic Directional metal ceramic
with Focal spot 0.4 to 1.5 with Focal spot 1.5×1.5 mm
mm
Cable Lengths 10 m Long (minimum) with 10 m Long (minimum) with
cable folding stowing and cable folding stowing and
protecting cover protecting cover
0.4 to 1.5 mm “Should be Focal spot 1.5×1.5
Focal Spot synchronized with our mm,Our machine is fit for
existing X-Ray System CRX Vision , not fit for GE
i.e. (CRX Vision and DXR DXR 250C-W. supported
250C-W) and supported for
for DR1012 digital
IPS and Digital detector with
certificate” detector
Cooling System Water Cooled or Air Cooled Air Cooled
Must be portable type and; Portable type; trolley /
Mobility for water cooled machines transport cart are optional.
must be mounted on trolley
/ transport cart (including
dust cover, document
compartment and non-
inflatable wheels)
Input Power Input:- 230 ± 10 VAC, 50 / Input: AC120V-265V (the
Requirement / 60 Hz Max 16A control system is compatible
output Operation Output:- DC voltage with full voltage and can
operation with constant meet requirements of
potential high dose output different generators for the
(low ripple) lowest voltage)
Output:- DC80V-250V
(Continuously adjustable for
different generators)
Operating
- 20ºC to +60ºC (or (-10℃~+40℃)
Temperature
equivalent specification)
Operating manual, Operating manual, Technical
Publications Technical manual, manual, (including error
Maintenance manual codes),
(including error codes),
Spare parts manual and
troubleshooting diagram (in
English), Training Videos
CDs , USB
Warranty / 03 Years 3 year (+ USD 980 )
Calibration
Standard accessories and Generator 1pc ;
Diaphragm / Collimator Controller 1pc ;
Accessories / attachments, Laser / Power cable YR2*2.5+1*1.5
Utilities Telescope Centering 10 M ;
(or equivalent device, Remote control Controller cable
specification) (with standard cable YR6*1.0+2*2.5+1*1.5 25 M ;
length), Safe lights Fuse 2A 2pcs ;
(Blinking + Flash lamp),
Ground cable 1pc ;
High quality storage boxes
Manual 1pc ;
(flight cases), 3 or 4 legs
Carrying cradle (all Product certificate 1pc ;
accessories are as per Warranty card 1pc ;
applicability), Inspection Warning light 1pc ;
stand and High- Direction collimator Indicator
performance mobile 1pc ;
workstation (high definition Remote 1pc
display), configured with
latest version with test
bench. These accessories
/ utilities are mandatory
for operational
utilization.
Standard tool kit for No need tool kit
Tool Kit
maintenance (all necessary
tools) and administrator kit
including interface cables,
CD-ROM, Bulb extracting
tool and USB’s.
Warm-up It has enabled fully automatic
(or equivalent Fully automatic, based on training function, automatic
specification) real time clock voltage reduction upon
discharge and automatic time
stepping;
Removable Control Module Removable Control Module
Control Panel
(Minimum 20m cable length (Minimum 25m cable length
with cable folding stowing) with cable folding stowing)
Additional Functions Change of focus, film focus
(or equivalent distance correction extended
specification) warm-up, Comprehensive
tube data base two slots for
activated tubes, power mode.
(for water cooled machine)
Spare Parts All necessary spares for 03 Any problem , send back the
Package year to be provided (control / generator or controller for
power cards, Bulb warranty (not include freight)
etc.)
Max 145 Kg (With 10M cable Max 58 Kg for total 1 generator
Weight and compact dimension) or + 1 controller + 25M cable +
equivalent (for water cooled) 10M cable + 1 light + 1
Max 27 kg (for air cooled Direction collimator Indicator
machine) or equivalent
Protection class IP65 or equivalent It is configured with waterproof
and dustproof warning lamp
socket to externally hold
AC220V exposure warning
lamp;
Duty Cycle 100% for 1hr operation time The ratio of exposure time to
operation time is strictly
controlled at 1:1.
Parameter Continuous online display of supply voltage and power
Monitoring device temperatures, supply rating (KV, mA, Time)
voltage and power
rating (KV, mA, Time)
Separate Stabilizer and surge It is arranged with safety door
Power Protection
protector for compatible power signal interlocking terminal,
rating for on-site which can be connected with
installation along with requisite lead door control to protect
fitting. personal safety;
Certifications CE Conformity, NFC 74100. CE