A complete electronic system uses a solenoid-operated fuel injector, which works intermittently and opens
at set times in the engine cycle. It remains open for a period of time, which is proportional to the quantity of
fuel required. A number of different types of full electronic system are in use. The main difference among
them is the method of measuring the air flow. The two main measuring systems are:
(i) Indirect or pressure-sensed air flow measurement.
(ii) Direct air flow measurement.
9.25.1.
Bosch D-Jetronic.
This system is an example of a pressure-sensed system (The letter ‘D’ stands for Druck, which means
pressure in the German language). The basic layout of this type of system is shown in Fig. 9.99 where the
quantity of air induced into the engine for a given throttle opening depends on the manifold pressure. A
MAP sensor measures the manifold pressure and sends an electrical signal to the ECU to indicate the
quantity of air entering the engine. After processing the signal, the ECU determines the period of time for
the injector to remain open.
Commencement of injection is triggered by either a switch in the ignition distributor or a sensor placed
adjacent to the flywheel or crankshaft pulley. For six-cylinder engines, the injectors are operated in sets of
three, i.e. three injectors spray at the same time. Extra fuel
provision for cold starting is similar to that used in the K-Jetronic. The ECU receives messages from a
number of sources (Fig. 9.100), and after processing the data as per the instructions programmed into its
built-in memory, the ECU signals the injectors to operate accordingly. Some of the other items that are used
to control the system are shown in Fig. 9.101. The throttle position switch works in conjunction with the
MAP sensor for measurement of air flow.
Fig. 9.99. Basic layout of electronic system of petrol injection.
9.25.2.
Hot-wire Metering.
The principle of the system, illustrated in Fig. 9.103, is based on the cooling of a hot surface, due to air
blown over it, and the rate of heat transfer depends on the rate of air flow. Both the Lucas EFI and the Bosch
LH-Jetronic employ this method of air flow measurement.
The hot wire element of the sensor is heated by an electric current, which is sufficient to maintain it at a
constant temperature. The cooling action increases with the increase of air flow, and therefore to maintain
the temperature taking account of the losses, a larger current has to be passed through the wire filament. The
voltage corresponding to this current provides an indication of the air flow. The ECU receives this voltage
to compute the basic quantity of fuel, which is then slightly altered taking into consideration of the signals
received from other engine
sensors.
!
Fig. 9.103. Hot-wire sensing.
As the air temperature affects the accuracy of the system, a compensating resistor is placed in the air stream.
A change in air temperature causes the resistor to alter its resistance, which compensates for the effect of a
change of air temperature. Hot-wire sensing system controls air-fuel ratio within the limits required to meet
emission regulations in force in various countries, and hence today this system is employed in many cars.
9.25.3.
Fuel System
Even though many different electronic systems of control are in use, the basic fuel supply system and the
supporting electrical circuitry are often similar. A typical fuel supply system is now described to explain the
basic principal of the main hydraulic components. Figure 9.104 shows the main components of the fuel
system. The fuel supply system uses the injectors (described in section 9.26) with adequate fuel at a pressure
sufficient for the injectors to provide good atomisation. The fuel pressure must not vary as the quantity of
fuel injected depends on this pressure.
Pump.
Generally a roller-type rotary pump is used, which is operated by a permanent-magnet electric motor (Fig.
19.105). The rollers move outwards with the rotation of the pump and seal the spaces between the rotor and
casing. Since the fuel is carried around with the rotor, the pressure increases due to the rotor movement
combined with the decrease in volume of the pumping chamber. The pump supplies fuel through the motor
to assist cooling. More quantity of fuel is supplied than required, and excess fuel is re-circulated back to the
tank, which reduces the vapour lock problems.