SPECIFICATIONS

PF2000 Series (Special Mounting)


Checkball Piston Pumps
Also refer to "Checkball Pump Service, Installation and Operating
Instructions" (dynexpumpservice.pdf)

CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: sales@dynexhydraulics.com

Power Units & Systems


Dynex/Rivett Inc.
54 Nickerson Road
Ashland, MA 01721 U.S.A.
Tel: 508-881-5110
FAX: 508-881-6849
E-mail: ashland@dynexhydraulics.com

European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, St Neots,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: sales@dynexhydraulics.co.uk

www.dynexhydraulics.com
BROCHURE NOTES:
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative or the sales department for the most current specifications before ordering.
Dynex reserves the right to discontinue products or change designs at any time without incurring any
obligation.

DYNEX High Pressure Hydraulics

Copyright © Dynex/Rivett Inc. Bulletin dynexpf2000smspecs-0718


PF2000 SERIES SPECIAL MOUNTING

Specifications
Output Flow Output Flow Maximum
at 1500 rpm➀ at 1800 rpm➀ Rated Intermittent
Pressure Pressure Rated Maximum
Pump U.S. U.S. Speed Speed
Models gpm L/min gpm L/min psi bar psi bar rpm rpm
S.A.E. Ports:
PF2006-1808 3.3 12,6 4.0 15,1 6000 420 8000 560 2000 2400
PF2008-1804 4.7 18,0 5.7 21,6 3000 210 5000 350 2000 2400
N.P.T.F. Ports:
PF2006-1807 3.3 12,6 4.0 15,1 6000 420 8000 560 2000 2400
PF2008-1802 4.7 18,0 5.7 21,6 3000 210 5000 350 2000 2400
➀ Output flow based on typical performance at rated pressure with pressurized inlet where required, as
PUMP DESCRIPTION shown in the “Minimum Inlet Pressure” table.

Fixed displacement checkball pumps, with


bi-directional shaft rotation, provide
constant direction of output flow regardless Minimum Inlet Pressure ➀
of the direction of drive shaft rotation. Operating Speed
2000 rpm 2400 rpm
Mounting Pump
Models psi bar psi bar
Special 4-bolt pattern. Refer to installation
All PF2000 Models
drawing. (Special Mounting)
0 0 5 0,4

Shaft ➀ Values shown are based on fluid viscosity of 100 SUS (20 cSt). Inlet pressures higher than 10 psig
(0,7 bar) require a high-pressure shaft seal.
Available with 1.25 inch (31,75 mm)
diameter keyed shaft.
Outlet Port Options
Available with S.A.E. or N.P.T.F. ports. Refer PUMP SELECTION Split-Flow® Provides Multiple Outlets
to the “Specifications” table. These PF2000 Series pumps can efficiently
The “Specifications” table lists the most
supply flows for multiple function circuits.
Inlet Conditions commonly used standard models with
keyed shafts. Contact the sales department Split-Flow® models are available with
Pumps may require pressurized inlet
for models with optional seals and other isolator valves installed into the pump, to
conditions at higher speeds. Failure to meet
extraordinary operating requirements. separate one or more pistons from the main
minimum inlet requirements will result in
outlet. Up to six independent outlet flows
slight flow reduction. Refer to the table. Maximum Pressure are possible from this six-piston pump.
Seal Options Checkball pumps are especially suited When using isolator valves, high-pressure
Standard seals are Buna-N (Nitrile). Contact for applications susceptible to excessive models are limited to a maximum pressure
the sales department for other seal options. pressure spikes. of 6000 psi (420 bar).
The intermittent pressures listed are Contact the sales department for Split-Flow®
Weight (Mass) the maximum pressures a pump can model numbers.
43 lb (20 kg) sustain for occasional, short periods of
operation without appreciably reducing life
expectancy.
Fluid Guidelines
See page 6 for “Fluid Recommendations”.
Some pump models may require reduced
operating pressures when using low-
lubricity fluids.
Because of the wide range of fluid
characteristics, contact the sales
department for a review of any application
using non-petroleum based fluids.

2
PF2000 SERIES SPECIAL MOUNTING

Typical Performance Curves

Typical performance curves are based on 100 SUS (20 cSt) mineral oil with pressurized
inlet where required. Refer to the “Minimum Inlet Pressure” table on page 4.

INSTALLATION
All dimensions are shown in inches Refer to Bulletin PSI.CB for general installation
(millimeters in parentheses) and are and operating recommendations.
nominal. Refer to “Outlet Port Configurations” on
These PF2000 Series models have a special page 7 and the “Specifications” table on
4-bolt mounting pattern shown below. page 4 for model numbers to specify ports.

INLET PORT — NO.12 S.A.E.


AMERICAN STANDARD NO. 1212 OR 3/4 N.P.T.F. OUTLET PORT — NO.10 S.A.E.
4.375 WOODRUFF KEY OR 1/2 N.P.T.F.
.375 x 1.50 (9,52 x 38,1) 3.81
(111,12)
.56 (96,8)
(14,2)
(
∅ 1.2486 31,714
1.2483 31,707 )

∅ 2.468
2.466

(
62,69
62,64 )

1.25
(
1.404 35,66
1.414 35,92 ) (31,75)

2.81 3.16 .38 ∅ 4.19


∅ .531 (13,49)
(71,4) (80,3) (9,7) (106,4)
4 MOUNTING HOLES
5.63 3.06 8.58
(143,0) (77,7) (217,9)

3
FLUID RECOMMENDATIONS Hydraulic Fluid Viscosity
(All Checkball Pumps) Operating
Minimum Maximum Start-up Optimum
Mineral Oil Pump
A high-grade premium petroleum-based Models SUS cSt SUS cSt SUS cSt SUS cSt
fluid should be used to assure long Fixed Displacement Pumps:
component and system life. The fluid PF500-10 52 8 1911 413 3706 800 98 to 324 20 to 70
should have a combination of anti-wear,
PF1000-10 59 1,3 1911 413 3706 800 98 to 324 20 to 70
demulsibility, rust protection, oxidation-
resistant and foam-resistant properties. PF1300-10 31 10 927 200 927 200 – –
PF2000 59 10 1911 413 1911 413 98 to 324 20 to 70
Special Fluids PF2000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
Various pump models are available
PF3000-10 59 10 1911 413 3706 800 98 to 342 20 to 70
for use with water-based fluids, diesel
calibration fluids, phosphate ester fluids, PF4000-30 34 2,3 1911 413 1911 413 98 to 324 20 to 70
machining coolant, brake fluid, various PF4200-10 34 2,3 1911 413 1911 413 98 to 324 20 to 70
military fluids and other special fluids. PF4300-20 31 1,5 927 200 927 200 – –
PF1300 & PF4300 Series pumps are PF6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
compatible with a variety of water-
Mechanical Variable Delivery Pumps:
based fluids. Refer to specific product
documentation for specifications for PV4000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
these models, which are specifically rated PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
for use with low-lubricity fluids. Hydraulic Variable Delivery Pumps:
Some pump models may require reduced PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
operating pressures when using low-
 Fluid conditions outside the “Optimum” range may result in reduced output, requiring pressurized inlet
lubricity fluids. conditions. Contact the sales department.
Because of the wide range of fluid  Models with special mounting.

characteristics, contact the sales depart-


ment for a review of any application using
non-petroleum based fluids. MINIMUM FILTRATION LEVELS INSTALLATION AND OPERATION
Viscosity Specifications Pump inlet: 150 µ nominal; Refer to separate Bulletin: Checkball
Using fluid with the correct viscosity Pressure or return line: 25 µ nominal. Pumps Service, Installation and Operating
range is critical to achieving long Instructions for general installation and
component life. While finer filtration levels than these operating recommendations.
are desirable and will result in longer
Fluid conditions outside the “Optimum” component life, restricting flow to the That brochure includes information on
range shown in the table may result pump inlet should be avoided. Minimum mounting, shaft loading, sizing inlet pipe
in reduced pump output, requiring recommended inlet conditions must be and hose, air bleed procedures and initial
pressurized inlet conditions. For maintained. start-up. Guidelines for maintenance,
more information, contact the sales repair and trouble-shooting are also
department. If a system component fails resulting in included.
fluid contamination, it is important to
drain and clean the reservoir, all lines,
filter screens and all components. Refill
with new fluid.

4
OUTLET PORT CONFIGURATIONS

PORT DESCRIPTIONS Coned and Threaded Ports The recommended fitting has a recessed
seal cavity formed by a shoulder on the
Dynex pumps are available with outlet ports underside of the flanged wrench flat (Voss
suitable for use at various pressure ranges. TUBING GLAND NUT
“Peflex”, Form B Shoulder Seal; or Parker
Refer to the appropriate “Specification Type E, “EOlastic” Seal; or equivalent).
Table” or “Typical Model Code” to specify
the required port. B.S.P. ports are not recommended for
operation above 10 000 psi (700 bar).
Contact the fitting manufacturer to ensure SLEEVE Contact the fitting manufacturer, to ensure
the selected fittings are rated for the PUMP
WEEP the selected fittings are rated for the
maximum pump operating pressure. COVER
HOLE
maximum pump operating pressure.

S.A.E. Straight Thread Ports Typical Coned and Threaded


port connection S.A.E. 4-Bolt Flange Ports
High-pressure pumps are available with
COUPLING coned and threaded outlet ports, which use FLANGE
Autoclave Medium Pressure, Butech M/P, or BOLTS

equivalent fittings.
These fittings provide a metal-to-metal seal O-RING
O-RING
with an interference fit, not requiring an
PUMP o-ring. The gland nut holds the sleeve and
COVER
tubing against the cone surface. PUMP
COVER
A weep hole, visible on the outside of
Typical S.A.E. Straight Thread the pump cover, acts as an indicator of Typical S.A.E. 4-Bolt Flange
port connection port connection
any abnormal leakage caused by system
The Straight Thread connection (S.A.E. conditions (i.e., excessive pressure). It allows Flange connections are often used for
J1926/1) is sometimes referred to as an any fluid which does leak past the sealing higher flows requiring larger diameter
S.A.E. O-ring Boss, or ORB. The port consists surfaces to escape, preventing pressure tubing. The port consists of an unthreaded
of a machined spotface surface, a tapered build-up and possible damage. port with four bolt holes in a rectangular
seal cavity and a straight thread port. pattern on a machined face around the port
The fitting forms a seal by compressing the British Standard Pipe Ports (S.A.E. J518).
o-ring in the seal cavity with the underside A typical fitting consists of a flanged head
of the flanged wrench flat. Some adjustable with a welded tube and a captive flange
fittings, such as elbows and tees, use a COUPLING
with bolt holes. A seal is formed by an
locknut with a captive backup washer for o-ring in the groove on the underside
compression. SEAL RING
mounting surface of the flange head. As the
S.A.E. Straight Thread ports are not flange bolts are alternately tightened, the
recommended for operation above SHOULDER
o-ring is compressed between the flange
8000 psi (560 bar). Also, the maximum head and the machined face on the pump.
PUMP
pressure of pumps with No. 12 S.A.E. outlet COVER To make mounting easier in tight spaces a
ports may be limited by the pressure rating two-piece split-flange is often used.
of the available fitting. Contact the fitting
Typical port connection with
manufacturer for ratings. British Standard Pipe (Parallel)
fitting with shoulder

High-pressure pumps are available with flat


face ports with British Standard Pipe (B.S.P.)
parallel threads (BS 2779 or ISO 228), ideal
for use on some European applications.
The fitting forms a seal by compressing a
flat elastomer ring on a machined spotface
surface. There are several sealing methods
for these ports.