Capstone Capstone Turbine Corporation • 21211 Nordhoff Street • Chatsworth • CA 91311 • USA

Telephone: (818) 734-5300 • Facsimile: (818) 734-5320 • Website: www.microturbine.com

Service Bulletin SB0039


Date: July 2002
From: Capstone Technical Support
Subject: Inspect Foil Bearing RFC Heat Exchanger

Affected
All Low Pressure Foil Bearing RFC Model C30 MicroTurbine systems supplied by Capstone
Turbine Corporation®.
Safety Precautions
Only Capstone Authorized Service Providers (ASP’s) should open the MicroTurbine and
other equipment connected to the MicroTurbine. The systems can include multiple sources
of power. Observe and adhere to the Safety Instructions contained within the MicroTurbine
manuals.
Summary
Damage may occur to the heat exchanger during shipping or installation. This may result in
fuel leaks, which can lead to safety issues or further component damage. Systems should
be inspected to ensure that no cracks or visible damage is present at the heat exchanger.
To ensure reliability, an upgrade kit is available for all Low Pressure Foil Bearing RFC Model
C30 MicroTurbine Systems and Retrofit Kits, containing an intercooler and bracket
assembly.
If you have additional questions, please Capstone Technical Support:
Telephone: (818) 407-3600
Facsimile: (818) 734-1080
Toll Free Telephone: (877) 282-8966
E-mail: service@capstoneturbine.com

450003-001 Rev A (July 2002) Page 1 of 1 SB0039