FINAL TERM PROJECT

Subject: Electrical Service Design Lab


Session: Summer 2022
Student Name: Student ID:
Question:
The use of proper lighting in a workplace is important both for the workers and the manufacturer. Poor lighting at the workplace leads
to eye strain, fatigue, and accidents, and too much light causes safety and health issues like glare-related headaches and stress. But
both these scenarios lead to more errors hence more reworks, poor quality and low productivity.
An 8-storey, RMG industry in Gazipur is having electrical bulb layout system shown here in figure 1. This layout is for floor number
5 (9,512 square ft). Initially, there was an abundant amount of natural light. So, they consider less lux (5000 lux/meter square area) for
the floor. But right now, a new building has been made in front of the industry which will block the light. For this reason, the
respective engineers ask to redesign the lighting system with 10,000 lux/meter square area. Engineers need to select 32 watts LED
bulbs with 3000 lumens per bulb.
Think of yourself as an engineer in this post and try to solve this issue. In the project report, please include the information’s given
below:
1. Total luminaries’ calculation for that floor. [ select any UF and MF value which will be practical towards the calculation].
2. Modify and create a new electrical bulb layout design by using AUTOCAD and attach with your report.
3. List out the issues that you have encountered during the design following BNBC rules. Also remember design must comply
with the BNBC rules (Volume 3, section 4.5.2). 
4. Describe the environment and sustainability of LED bulbs for this industry.
FINAL TERM PROJECT

Figure 1. Fifth floor lighting design


FINAL TERM PROJECT

Assessment Rubrics for P.e.2.P4


Marking Area Poor (0-1) Medium (2-3) Good (4-5) Overall Marks /20
Luminaries’ Didn’t make any Right equations have Proper equation with
calculation calculation or wrong been selected but the accurate luminary
(Supports P1, K3) equation has been variable values are not number
selected exact
New electrical layout Didn’t prepare the Number of luminaries Proper layout with
(Supports P1, K5) layout or layout is not doesn’t match with the perfect setting of
understandable new layout luminaries
List of issues No issues have been Moderate number of Most of the important
(Supports P4) described or issues are issues are described issues are included in
not related with topics report
Sustainability and code Zero description or Less information Most of the important
of ethics doesn’t match with information’s has been
(Supports P5) topics provided
Total Marks =
FINAL TERM PROJECT

# Total Luminaries Calculation (Please show the calculation in this page and detail information about the calculation)
FINAL TERM PROJECT

# List out the issues in this page


FINAL TERM PROJECT

# List out the sustainability and code of ethics in this page

# Draw the modified design in AutoCAD and convert it into pdf and take a print out. Attach that print out with this report.
Please write your name and ID inside the AutoCAD design.