General Description
Construction
Filtration
Model Codes
V 2 ** - * - 1 * - 12-S214 - LH -INB - IN
Indian Modification
Omit for standard pumps
Design number
Design numbers subject to change
installation dimensions remain the
same for design numbers 10 thru 19
Outlet position
(Viewed from cover end)
A-Outlet opposite inlet
B-Outlet 90° counterclockwise from inlet
C-Outlet in line with inlet
Shaft type.
1 - Straight keyed (std)
3 - Woodruff key and External Threads
6 - Woodruff key with flat
7 - Splined shafts
24 - Tang shaft
52 - Splined shafts
152 - Splined shafts
Rated Capacity.
(1200 rpm-7kg/cm2)
2 - 7.6 I/min (2 GPM)
5 - 19.0 I/min (5 GPM)
6 - 22.7 I/min (6 GPM)
8w - 30.3 I/min (8 GPM)
9w - 34.1 I/min (9 GPM)
11w - 41.6 I/min (11 GPM)
Mounting type.
10 - Flange mounting threaded ports
14 - foot mounting threaded ports
30 - face mounting threaded ports
35 - Auxiliary flange mounting
- threading ports
05 - Flange mounting flange
- ports
Series
Vane type.
V Series - Single Vane Pumps
Single Vane Pump V200 Frame Size
Construction
Model V200 pumps are of Vickers “balanced vane type”construction.
Filtration
For maximum over-all efficiency and service life filtration of 25 Micron or less is recommended for fire
resistant fluids. This filtration is mandatory.
Shaft rotation
Pumps are normally assembled for righthand or clockwise rotation as viewed from shaft end. If lefthand or
counter clockwise rotation is required specify by adding suffix “LH” to model number.
Product
Product code Part no. Description / Model Code
Level 3
201406111 V 200 247169-INB-1 V210-11W-1A-12-S214-INB
201406112 V 200 247169-INB-5 V210-11W-1A-12-S214-LH-INB
201406113 V 200 247169-INB-2 V210-11W-1B-12-S214-INB
201406114 V 200 247169-INB-6 V210-11W-1B-12-S214-LH-INB
201406115 V 200 247169-INB-3 V210-11W-1C-12-S214-INB
201406116 V 200 247169-INB-7 V210-11W-1C-12-S214-LH-INB
201406117 V 200 247169-INB-4 V210-11W-1D-12-S214-INB
201406118 V 200 247169-INB-8 V210-11W-1D-12-S214-LH-INB
201406119 V 200 5002374-001-3 V210-11W-38C-12-S214-IN167
201406120 V 200 245359-IN102-4 V210-11W-3D-12-S214-IN102
201406121 V 200 131572-INB-1 V210-2-1A-12-S214-INB
201406122 V 200 131572-INB-3 V210-2-1C-12-S214-INB
201406123 V 200 131572-INB-7 V210-2-1C-12-S214-LH-INB
201406124 V 200 131573-INB-1 V210-5-1A-12-S214-INB
201406125 V 200 131573-INB-2 V210-5-1B-12-S214-INB
201406126 V 200 131573-INB-3 V210-5-1C-12-S214-INB
201406127 V 200 131573-INB-7 V210-5-1C-12-S214-LH-INB
201406128 V 200 131574-IN-102-7 V210-5-3C-12-S214-LH-IN102
201406129 V 200 136770-INB-4 V210-5-6D-12-S214-INB
201406130 V 200 179962-INB-1 V210-6-1A-12-S214-INB
201406131 V 200 179962-INB-3 V210-6-1C-12-S214-INB
201406132 V 200 179962-INB-7 V210-6-1C-12-S214-LH-INB
201406133 V 200 179962-INB-4 V210-6-1D-12-S214-INB
201406134 V 200 246412-INB-1 V210-8W-1A-12-S214-INB
201406135 V 200 246412-INB-2 V210-8W-1B-12-S214-INB
201406136 V 200 246412-INB-3 V210-8W-1C-12-S214-INB
201406137 V 200 246412-INB-4 V210-8W-1D-12-S214-INB
201406138 V 200 5002375-001-1 V210-8W-24A-12-S214-IN2
201406139 V 200 5002375-001-5 V210-8W-24A-12-S214-LH-IN2
201406140 V 200 5002375-001-2 V210-8W-24B-12-S214-IN2
201406141 V 200 5002378-001-2 V210-8W-24B-12-S214-INB
201406142 V 200 5002378-001-6 V210-8W-24B-12-S214-LH-INB
201406143 V 200 5002378-001-3 V210-8W-24C-12-S214-INB
V Series - Single Vane Pumps
Single Vane Pump V200 Frame Size
Construction
Model V200 pumps are of Vickers “balanced vane type”construction.
Filtration
For maximum over-all efficiency and service life filtration of 25 Micron or less is recommended for fire
resistant fluids. This filtration is mandatory.
Shaft rotation
Pumps are normally assembled for right hand or clockwise rotation as viewed from shaft end. If lefthand or
counter clockwise rotation is required specify by adding suffix “LH” to model number.