You are on page 1of 52

Catalogue

Intra–Vane Pump for Industry Application ...................................................................................................................... 2


V series single pump ............................................................................................................................................... 3
Single pump Technical Data ...................................................................................................................................... 4
V series double pump .............................................................................................................................................. 5
Double pump Technical Data ..................................................................................................................................... 6
Output flow and input power performance characteristic ................................................................................................... 7
Configuration and installation dimension (mm) ............................................................................................................... 11
V series cartridge kits ............................................................................................................................................ 15
V10/V20 series single pump ..................................................................................................................................... 16
Technical Data..................................................................................................................................................... 17

Intra–Vane Pump for Mobile Equipment ........................................................................................................................ 18


VQ series single pump ............................................................................................................................................ 19
VQ series double pump ........................................................................................................................................... 20
Technical Data..................................................................................................................................................... 21
Output flow and input power performance characteristic .................................................................................................. 22
Configuration and installation dimension (mm) ............................................................................................................... 28
VQ series cartridge kits........................................................................................................................................... 31

Lower Noise Intra-Vane Pump ................................................................................................................................... 32


SQPV series single pump ......................................................................................................................................... 33
Technical Data..................................................................................................................................................... 34
SQPV series double pump ........................................................................................................................................ 35
Technical Data..................................................................................................................................................... 36
Output flow and input power performance characteristic .................................................................................................. 37
Noise characteristic ............................................................................................................................................... 40
Configuration and installation dimension (mm) ............................................................................................................... 41
SQPV series cartridge kits ........................................................................................................................................ 46

Outlet position .................................................................................................................................................... 47


Straight key shaft type ........................................................................................................................................... 48
Splined key shaft type ............................................................................................................................................ 49
Port flange kits .................................................................................................................................................... 50
Foot mounting bracket options for port........................................................................................................................ 52

1 www.dexco.com.br
www.dexcohydraulics.com
Intra–Vane Pump for Industry Application

This series of pumps are developed to meet the increasing demands of machine – tool industry. Total 4
series including 19 kinds are available, whose displacement ranges from 18mL/r to 193mL/r, maximum
continuous operating pressure is 17.2MPa, the speed of rotation ranges from 600 rpm to 1800 rpm. The intra-
vane structure ensures many good characteristics such as high pressure, large capacity, small volume, smooth
operation, low noise, efficient capacity efficiency and long service life etc. The main technical data has reached
an advanced level in the international market of the same trade.
This series of pump is composed of replaceable cartridge kits, which reduce the construction time thus
enhance production efficiency. Optimum design of pump core further reduce the pressure shimmy, flow
pulsation and noise of the pump, sound pressure balance which compensate the space can have better capacity
efficiency. The proper design of oil supply system between vane and intra-vane enables good contact between
blade and stator and ensure minimum floe. The unique design, high-precision processing and rational material
selections prolong the service life of the pump.
With complete specification, reliable performance, simple and rational structure, convenient installation
and repairing (the connection complies with ISO and SAE), the pump is widely used in machine-tool, press and
die-casting machines, engineering, plastic injection moulding and other machineries.

2 www.dexco.com.br
www.dexcohydraulics.com
V series single pump

F3 **V 12 A M F 1 A 10 L

Port
Port Mountig Outlet Design
Refit Series Code connection Shaft type Rotation
connection type position number
thread

5, 8, 9, (viewed
20V 11, 12, 1 – straight from cover
14 keyed end of
pump)
F3 – M – Metric Flange (viewed from
10, 12, 151 – spline A–
Viton seals thread mounting, shaft end of
25V 14, 17, (for 20V opposite
omit pump)
21 only) inlet port
L – left hand
A-SAE 4-bolt B–
10 for counter
flange 86 – heavy 90° CCW
clock wise
25, 30, duty straight from inlet
35V keyed
35, 38
C–
Omit it not I – Inch F – Foot R – right hand
in line with
requered thread, omit mounting for clockwise
11 – splined inlet
(not
42, 45, available on D–
45V 20V) 90° CW from
50, 60
inlet

Rated flow Usgpm at 1200rpm and 0.7 MPa.

3 www.dexco.com.br
www.dexcohydraulics.com
Single pump Technical Data

Using anti-wear
Sound levels at
hydraulic oil or Using water Using water-in-oil
13.8MPa, 26cSt and
phosphate ester glycol fluid emulsions
Geometric Min 50°C rpm
fluid Weight
Series Code displacement speed
(Kg)
(mL/r) Max. Max. Max. Max. Max. (rpm)
Max.
pressure speed pressure speed pressure 1200 1500 1800
speed
(MPa) (rpm) (MPa) (rpm) (MPa)

5 18
8 27
21 16
9 30
20V 62 64 66 12
11 36
12 40 16
14 45 14 14
10 33
12 39
25V 14 45 63 65 67 14.6
1800 1500 600
17 55 7 1200
21 67
25 81
17.2
30 97 17.2
35V 64 66 69 22.7
35 112
38 121
42 138
45 147
45V 67 69 71 34
50 162
60 193

4 www.dexco.com.br
www.dexcohydraulics.com
V series double pump

F3 ****V 21 11 A M F 1 CC 10 L

Code
Code
view
view Port
from Port Mountig Outlet Design
Refit Series from connection Shaft type Rotation
cover connection type position number
shaft end thread
end
pump
pump
10, 12, 5, 8, 9,
2520V 14, 17, 11, 12,
21 14
1 – straight
(viewed
keyed
10, 12, 10, 12, from
2525V 14, 17, 14, 17, shaft
F3 – 21 21 end of
Flange
Viton pump)
5, 8, 9, M – Metric mounting, 86 – heavy
seals 25, 30,
3520V 11, 12, thread omit duty straight
35, 38 keyed
14
L – left
10, 12, Check
25, 30, A-SAE 4- hand for
3525V 14, 17, description 10
35, 38 bolt flange counter
21 11 – splined on page 47
clock
(not
wise
5, 8, 9, I – Inch available on
42, 45,
4520V 11, 12, thread, 2525V)
Omit it 50, 60
14 omit F – Foot
not
mounting
requered 10, 12, R – right
42, 45, hand for
4525V 14, 17, 174 – splined
50, 60 clock
21 keyed (only
wise
for 2525V)
42, 45, 25, 30,
4535V
50, 60 35, 38

Rated flow Usgpm at 1200rpm and 0.7 MPa.

Recommendations
The oil in a hydraulic system serve as the power transmission medium. It is also the system’s lubricant and
coolant. Selection of the proper oil is a requirement for satisfactory performance and life.

Important Factor in Selecting Oil Additives


Hydraulic fluids contain a number of additive agents which materially improve various characteristics of oil for
hydraulic systems. These additives are selected to reduce wear, increase chemical stability, inhibit corrosion
and doers the pour point. Pump performance and reliability and directly affected by the anti-wear additive
formulation contained in the oil. Oil providing a high level of anti-wear protection are recommended for
optimum performance and long life.

5 www.dexco.com.br
www.dexcohydraulics.com
Double pump Technical Data

Using anti-wear
Using water-in-oil
hydraulic oil or Using water glycol fluid
emulsions
Geometric Min phosphate ester fluid
Series Code displacement speed
(mL/r) (rpm) Operating Max. Operating Max. Operating Max.
pressure speed pressure speed pressure speed
(MPa) (rpm) (MPa) (rpm) (MPa) (rpm)

5 18
8 27
21 16
9 30
20V
11 36
12 40 16
14 45 14 14
10 33
12 39
25V 14 45
1800 1500
17 55 600 7 1200
21 67
25 81
16
30 97 17.2
35V
35 112
38 121
42 138
45 147
45V
50 162
60 193

6 www.dexco.com.br
www.dexcohydraulics.com
Output flow and input power performance characteristic

Typical flows at 50°C (120°F), 26cSt (128SUS), 0MPa (0psi) inlet at rated speed.

7 www.dexco.com.br
www.dexcohydraulics.com
8 www.dexco.com.br
www.dexcohydraulics.com
9 www.dexco.com.br
www.dexcohydraulics.com
10 www.dexco.com.br
www.dexcohydraulics.com
The Input Power Formula of Oil Pump
The calculation of input power is the basics of choosing the motor of oil pump. At particular pressure △P, the
driving power W changes with the change of output flow Q.


W= (kW)

Note: △ P – The pressure difference between inlet and outlet position of pump (MPa).

ɳm – The mechanical efficiency of pump (Generally, the mechanical efficiency of intra-vane pump is
0.90).

Configuration and installation dimension (mm)

11 www.dexco.com.br
www.dexcohydraulics.com
Model A B øC D E ØG H J L M øN

101.6
25V 35.7 26.2 25.4 52.4 12.7 38.1 117.4 69.9 120.7 38.1
101.55

127.00
5V 42.9 30.2 31.8 58.7 15.7 50.8 140 77.7 125.5 38.1
126.95

127.00
45V 61.9 35.7 38.1 69.9 16.0 76.2 159 106.4 153 42.9
126.95

Model P Q R S T ØV W øX ØF x Full thread depth 4 holes ØK x Full thread depth 4 holes

1/2”-13UNC-2B x 23.8 deep or


25V 9.53 164.1 63.5 76.2 146 14.2 174.5 121 3/8”-16UNC-2B x 19 deep or M10
M12

7/16”-14UNC-2B x 22.3 deep or 1/2”-13UNC-2B x 22.3 deep or


35V 9.53 186.9 69.9 82.6 181 17.5 213 147.6
M12 M12

1/2”-13UNC-2B x 22.8 deep or


45V 12.7 216.9 82.6 93.7 181 17.5 213 147.6 5/8”-11UNC-2B x 30 deep or M16
M12

12 www.dexco.com.br
www.dexcohydraulics.com
Model A B C øD E øF G øU J øK øL M

101.60
2520V 50.8 26.2 12.7 25.4 52.4 9.53 63.5 88.9 19.1 14.2 76.2
101.55

101.60
2525V 50.8 26.2 12.7 25.4 52.4 9.53 63.5 88.9 25.4 14.2 74.7
101.55

127.00
3520V 61.9 30.1 15.9 31.7 58.7 9.53 76.2 106.4 19.1 17.5 76.2
126.95

127.00
3525V 61.9 30.1 15.9 31.7 58.7 9.53 76.2 106.4 25.4 17.5 74.7
126.95

127.00
4520V 69.9 35.7 15.9 38.1 69.9 12.7 88.9 120.7 19.1 17.5 76.2
126.95

127.00
4525V 69.9 35.7 15.9 38.1 69.9 12.7 88.9 120.7 25.4 17.5 74.7
126.95

127.00
4535V 77.8 35.7 15.9 38.1 69.9 12.7 101.6 130.2 31.7 17.5 101.6
126.95

13 www.dexco.com.br
www.dexcohydraulics.com
Model N P Q R S T U ØV X Y Z

2520V 88.1 101.6 38.1 76.2 252.5 85.3 146.1 121 174.7 22.2 47.6
2525V 97.5 101.6 38.1 76.2 263 84 146.1 121 174.7 26.2 52.4
3520V 99.6 114.3 38.1 82.6 276.6 88.9 181 147.6 213 22.2 47.6
3525V 109.5 114.3 38.1 82.6 293.9 88.9 181 147.6 213 26.2 52.4
4520V 119.9 119.4 42.9 93.7 306.8 102.4 181 147.6 213 22.2 47.6
4525V 136 119.4 42.9 93.7 329.9 102.4 181 147.6 213 26.2 52.4
4535V 148.3 133.3 42.9 93.7 353 102.4 181 147.6 213 30.2 58.7

14 www.dexco.com.br
www.dexcohydraulics.com
V series cartridge kits

1 2 3 4 5 6
CK - 25V - 14 R B - 10

1 2 3 4 5 6

20V-18 ~ 45mL/rev Rotation


(view from smaller end)
CK 25V-33 ~ 67mL/rev
Displacement L – left hand for counter B – no bush, omit if not 10 – design
Cartridge
code clockwise required number
Kits
35V-81 ~ 121mL/rev
R – right hand for clockwise,
omit
45V-138 ~ 193mL/rev

Geometric displacement
Series Code
mL/r in³/r
5 18 1.10
8 27 1.67
9 30 1.85
20V
11 36 2.22
12 40 2.49
14 45 2.78
10 33 2.01
12 39 2.47
25V 14 45 2.78
17 55 3.39
21 67 4.13
25 81 4.49
30 97 5.91
35V
35 112 6.83
38 121 7.37
42 138 8.41
45 147 8.95
45V
50 162 9.85
60 193 11.75

Model øA øB øC øD L M N P H X Y Z

20V 82.5 76.2 47.1 4.8 81.3 70.5 64.5 73.66 6 2-222 76.76x3x3.5 2-236
25V 96.8 90.5 52.2 4.8 98.7 86.6 77.6 88.18 7 2-224 91x3x3.5 2-241
35V 114.3 108 72.1 6.4 117.2 104.5 90.8 103.94 7 2-230 108.5x3x3.5 2-247
45V 133.3 127 80.1 6.4 140.4 119 105.8 123.8 8 2-233 127.6x3x3.5 2-253

15 www.dexco.com.br
www.dexcohydraulics.com
Intra–Vane Pump for Industry Application

V10/V20 series single pump

Product Introduction
V10/V20 series are widely used in engineering mechinery, injection moulding, rubber machinery and
Inthes etc.

Features
The housing with high strength and precision, 12 – vane design gets the ultra-low pulse and lower noise
coplete displecment, composite structure and high precise spare parts allows convenient maintenance.

Model Code

F3 V10 1 P 5 S 1 C 20 L

Inlet Flow Outlet Shaft Outlet Design


Series Mounting Rotation
connection code connection type position No

P-1”NPT
A:

1, 2, 3, opposite
1-2 bolt S-1.3125-
V10 4, 5, 6, 1: inlet port (viewed from
flange 12UNF-13
7 straight shaft end of
Omit if key B: 90° pump)
B-M33x2-7H
not CCW from
required 86: heavy inlet 20 L: left hand for
P-1.25”NPT duty key counterclockwise
Viton seals 6, 7, 8, C: in line
1-2 bolt S-1.625- 9, 10, 11 OSO: with inlet R: right hand for
V20
flange 12UNF-13 11, 12, Spline counterclockwise
13 D: 90° CW
B-M42x2-7H from inlet

16 www.dexco.com.br
www.dexcohydraulics.com
Technical Data

Using antiwear hydraulic oil Using water-in-oil


Using water glycol fluid
or phoshate ester fluid emulsions
Geometric
Model Displacement displacement
(mL/r)
Max. Max. Max.
Operating Operating Operating
speed speed speed
pressure (MPa) pressure (MPa) pressure (MPa)
(rpm) (rpm) (rpm)

1 3.3 1800

2 6.6 4500

3 9.8 4000 17.2 10.3

V10 4 13.1 3400 1800


1800 12.4
5 16.4 3200

6 19.5 2800 15.2


10.9
7 22.8 3400 13.8

6 19.5 3000

7 22.8

8 26.5 10.9 12.4


2800 17.2
9 29.7
V20 1800 1800
10 30.0

11 36.4 2500

12 39 9.3 10.9
2400 15.2
13 42.2

17 www.dexco.com.br
www.dexcohydraulics.com
Intra–Vane Pump for Mobile Equipment

This series of pumps are developed to meet the increasing demands of vehicle industry. Total 5 series
including 23 kinds are available, whose displacement ranges from 18 mL/r to 193 mL/r, maximum continuous
operating pressure is 21MPa, the speed of rotation ranges from 600 rpm to 2200 rpm. The adopting of intra-vane
structure ensures many good characteristics such as high pressure, large flow, small volume, smooth operation,
low noise, efficient capacity efficiency and long service life etc. The main technical data has reached an
advanced level in the international market of the same trade.
This series of pump is composed of replaceable cartridge kits, which reduce the construction time thus
enhance production efficiency. Optimum design of pump core further reduce the pressure shimmy, flow
pulsation and noise of the pump. Reliable pressure balance which compensated the space can have better
capacity efficiency. The proper design of oil supply system between vane and intra-vane enables good contact
between vane and stator and ensure minimum flow loss. The unique design, high-precision processing and
rational material selections prolong the service life of the pump.
With complete specification, reliable performance, simple and rational structure, convenient installation
and reparing (the connection complies with ISO and SAE), the pump is widely used in machine-tool, press and
die-casting machines, engineering, plastic injection moulding and other machineries.

18 www.dexco.com.br
www.dexcohydraulics.com
VQ series single pump

F3 20VQ 12 A M F 1 A 10 L

Port
Port Mountig Outlet Design
Refit Series Code connection Shaft type Rotation
connection type position number
thread
5, 8, 9,
20VQ 11, 12, (viewed
14 from
1 – straight
cover end
12, 14, keyed
25VQ 17, 19, of pump)
F3 –
Viton 21 M – Metric Flange
A–
seals thread mounting, 151 – spline
oposite (viewed from
30VQ 24, 28 omit (for 20VQ
inlet port shaft end of
only)
pump)
A-SAE 4-bolt B–
21, 25, 10
flange 90° CCW L – left hand for
35VQ 30, 35, 86 – heavy
from inlet counterclockwise
38 duty straight
R – right hand for
keyed
C– counterclockwise
Omit it I – Inch F – Foot
in line
not thread, omit mounting
with inlet
requered 11 – splined
42, 47, (not available
45VQ 50, D–
on 20VQ)
57,60 90° CW
from inlet

Rated flow Usgpm at 1200rpm and 0.7 MPa.

19 www.dexco.com.br
www.dexcohydraulics.com
VQ series double pump

F3 2520VQ 21 11 A M F 1 CC 10 L

Port
Port Mountig Shaft Outlet Design
Refit Series Code Code connection Rotation
connection type type position number
thread

12, 14, 17, 5, 8, 9,


2520VQ
19, 21 11, 12, 14

5, 8, 9,
3020VQ 24, 28 1:
11, 12, 14
straight
keyed
5, 8, 9,
21, 25, 30,
3520VQ
35, 38 11, 12, 14 (viewed from
shaft end of
151: pump)
F3: M: Flange
12, 14, spline
Viton 21, 25, 30, Metric mounting,
3525VQ (for 20VQ
seals 35, 38 17, 19, 21 thread omit
only)

Check
L:
21, 25, 30, 24, 28 A-SAE 4- descripti
3530VQ 10 left hand for
35, 38 bolt flange on on
86: counterclockwise
page 47
heavy
duty
5, 8, 9, I:
42, 47, 50, straight
Omit it 4520VQ Inch F:
57, 60 11, 12, 14 keyed
not thread, Foot
requered omit mounting
R:
right hand for
12, 14,
42, 47, 50, counterclockwise
4525VQ
57, 60 17, 19, 21 11:
splined
(not
available
42, 47, 50, on 20VQ)
4530VQ 24, 28
57, 60

21, 25,
42, 47, 50,
4535VQ
57, 60 30, 35, 38

Rated flow Usgpm at 1200rpm and 0.7 MPa.

20 www.dexco.com.br
www.dexcohydraulics.com
Technical Data

Using anti-wear hydraulic oil Using water-in-oil


Using water glycol fluid
Geometric Min or phoshate ester fluid emulsions
Series Code displacement speed
(mL/r) (rpm) Operating Max. Operating Max. Operating
Max. speed
pressure speed pressure speed pressure
(rpm)
(MPa) (rpm) (MPa) (rpm) (MPa)
5 18

8 27.4
21
9 29.3 16
20VQ 2700 1800
11 36.4

12 39.5 16

14 45.9 14 14

12 40.2 1500

14 45.4

25VQ 17 55.2 2500 21 16

19 60.7

21 67.5

24 76.2 600 14
30VQ 2500 14 14
28 88.2

21 67.9

25 81.6 1500

35VQ 30 97.7 2500 21

35 112.8

38 121.6
1200 16
42 138.7

47 148.3

45VQ 50 162.3 2200 17.2

57 179.6

60 193.4

21 www.dexco.com.br
www.dexcohydraulics.com
Output flow and input power performance characteristic

Typical flows at 50°C (120°F), 26cSt (128SUS), 0MPa (0psi) inlet at rated speeds.

22 www.dexco.com.br
www.dexcohydraulics.com
23 www.dexco.com.br
www.dexcohydraulics.com
24 www.dexco.com.br
www.dexcohydraulics.com
25 www.dexco.com.br
www.dexcohydraulics.com
26 www.dexco.com.br
www.dexcohydraulics.com
27 www.dexco.com.br
www.dexcohydraulics.com
Configuration and installation dimension (mm)

28 www.dexco.com.br
www.dexcohydraulics.com
Model A B øC D E ØG H J L M øN

101.6
25/30VQ 35.7 26.2 25.4 52.4 12.7 38.1 117.4 69.9 120.7 38.1
101.55

127.00
35VQ 42.9 30.2 31.8 58.7 15.7 50.8 140 77.7 125.5 38.1
126.95

127.00
45VQ 61.9 35.7 38.1 69.9 16.0 76.2 159 106.4 153 42.9
126.95

ØF x Full thread depth 4 ØK x Full thread depth 4


Model P Q R S T ØV W øX
holes holes

3/8”-16UNC-2B x 19 deep or 1/2”-13UNC-2B x 23.8 deep or


25/30VQ 9.53 164.1 63.5 76.2 146 14.2 174.5 121
M10 M12

7/16”-14UNC-2B x 22.3 deep 1/2”-13UNC-2B x 22.3 deep or


35VQ 9.53 186.9 69.9 82.6 181 17.5 213 147.6
or M12 M12

1/2”-13UNC-2B x 23.8 deep or 5/8”-11UNC-2B x 30 deep or


45VQ 12.7 216.9 82.6 93.7 181 17.5 213 147.6
M12 M16

29 www.dexco.com.br
www.dexcohydraulics.com
Model A B C øD E øF G øU J øK øL M

2520VQ 101.6
50.8 26.2 12.7 25.4 52.4 9.53 63.5 88.9 19.1 14.2 76.2
3020VQ 101.55

127.00
3520VQ 61.9 30.2 12.7 31.8 58.7 9.53 76.2 106.4 19.1 17.5 76.2
126.95

3525VQ 127.00
61.9 30.2 15.9 31.7 58.7 9.53 76.2 106.4 25.4 17.5 74.7
3530VQ 126.95

127.00
4520VQ 69.9 35.7 15.9 38.1 69.9 12.7 88.9 120.7 19.1 17.5 76.2
126.95

4525VQ 127.00
69.9 35.7 15.9 38.1 69.9 12.7 88.9 120.7 25.4 17.5 74.7
4530VQ 126.95

Model N P Q R S T U Øv X Y Z

2520VQ
88.1 101.6 38.1 76.2 252.5 85.3 146.1 121 174.7 22.2 47.6
3020VQ

3520VQ 99.6 114.3 38.1 82.6 276.6 88.9 181 147.6 213 22.2 47.6

3525VQ
109.5 114.3 38.1 82.6 293.9 88.9 181 147.6 213 26.2 52.4
3530VQ

4520VQ 119.9 119.4 42.9 93.7 306.8 102.4 181 147.6 213 22.2 47.6

4525VQ
136 119.4 42.9 93.7 329.9 102.4 181 147.6 213 26.2 52.4
4530VQ

30 www.dexco.com.br
www.dexcohydraulics.com
VQ series cartridge kits

1 2 3 4 5 6
CK - 25VQ - 14 R B - 10

1 2 3 4 5 6

20VQ-18 ~ 45mL/rev
Rotation
25VQ-33 ~ 67mL/rev (view from smaller end)
CK B – no bush, 10 –
Displacement
Cartridge 30VQ-76 ~ 88mL/rev omit if not design
code L – left hand for counter clockwise
Kits required number
35VQ-67 ~ 121mL/rev
R – right hand for clockwise, omit
45VQ-138 ~ 193mL/rev

Geometric displacement
Series Code
mL/r in³/r
5 18.0 1.10
8 27.4 1.67
9 29.2 1.85
20VQ
11 36.4 2.22
12 39.5 2.41
14 45.9 2.80
12 40.2 2.45
14 45.4 2.77
25VQ 17 55.2 3.37
19 60.7 3.70
21 67.5 4.12
24 76.2 4.65
30VQ
28 88.2 5.38
21 67.9 4.14
25 81.6 4.98
35VQ 30 97.7 5.96
35 112.8 6.88
38 121.2 7.42
42 138.7 8.46
47 148.3 9.05
45VQ 50 162.3 9.90
57 79.6 10.96
60 193.4 11.80

Model øA øB øC øD L M N P H X Y Z

20VQ 82.5 76.2 47.1 4.8 81.3 70.5 64.5 73.66 6 2-222 76.76x3x3.5 2-236
25VQ 96.8 90.5 52.2 4.8 98.7 86.6 77.6 88.18 7 2-224 91x3x3.5 2-241
30VQ 96.8 90.5 52.2 4.8 109.8 97.7 88.7 88.18 7 2-224 91x3x3.5 2-241
35VQ 114.3 108 72.1 6.4 117.2 104.5 90.8 103.94 7 2-230 108.5x3x3.5 2-247
45VQ 133.3 127 80.1 6.4 140.4 119 105.8 123.8 8 2-233 127.6x3x3.5 2-253

31 www.dexco.com.br
www.dexcohydraulics.com
Lower Noise Intra-Vane Pump

This series of pumps are developed by our company to meet the increasing demands of low noise in
machine-tool industry. Total 4 series including 37 kinds are available, whose displacement ranges from 7.5 mL/r
to 236mL/r. maximum continuous operating pressure is 17.2 Mpa, the rotation speed ranges from 600 rpm to
1800 rpm. The intra-vane structure can supply the pump with long service life and low noise, also high pressure
and large flow. The smooth operation and more efficient are the intrinsic attributes of the pump. Twelve-blade
pump construction assures the little amplitude of the pulsating flow and the low noise of the system. The shell
design is of quality shock absorption, which makes the noise the lowest and advances the comfort of the
operation. The main specification of technique achieve the advanced level among the same trade of the
products around the world.
This series of pump use replaceable cartridge kits, which can allow the repairmen on the spot and
reduce the construction time thus enhance production efficiency. The machine core module tested in the
factory can offer the performance of the new pump. The positions of input and output can be various which
make installation flexible and design convenient.
With complete specifications, reliable performance simple and rational structure, convenient installation
and repairing (the connection complies with ISO and SAE). The pump is widely used in machine-tool and plastic
machinery and many other hydraulic systems.

32 www.dexco.com.br
www.dexcohydraulics.com
SQPV series single pump

F3 SQPV2 21 M F 1 C 10 L

Port
Mountig Outlet Design
Refit Series Code connection Shaft type Rotation
type position number
thread

Omit using (viewed from


2, 3, 4, 5, 6,
anti-wear cover end of
SQPV1 7, 8, 9, 10,
oil or pump) (viewed from
11, 12, 14
phosphate shaft end of
ester fluid pump)
Flange
1 – straight A–
10, 12, 14, M – Metric mounting,
keyed opposite inlet
SQPV2 15, 17, 19, thread omit
F11 – port
Using 21, 25
water B– L – left hand for
10
glycol 90° CCW from counterclockwis
fluid 17, 21, 25, inlet e
SQPV3 30, 32, 35, I – Inch
38, 42 86 – heavy duty C–
thread, omit F – Foot
F3 – straight keyed in line with
mounting
Using inlet
water in- R – right hand for
30, 35, 38,
oil D– clockwise
SQPV3 42, 45, 50,
emulsions 90° CW from
60, 67, 75
inlet

Rated flow Usgpm at 1200rpm and 0.7 MPa.

Important factors in selecting oil chemical stability


Oxidative and thermal stability are essential characteristics of oils for mobile hydraulic systems. The
combination of base stocks and additives should be stable during the expected lifetime of the oil when exposed
to the environment of these systems.

33 www.dexco.com.br
www.dexcohydraulics.com
Technical Data

Using anti-wear
Using water-in-oil Using water glycol Weight
hydraulic oil or
emulsions fluid (Kg)
Geometric Min phoshate ester fluid
Series Code displacement speed
(mL/r) (rpm) Max. Operating Max. Operating Max. Operating
Flange Foot
speed pressure speed pressure speed pressure
mounting mounting
(rpm) (MPa) (rpm) (MPa) (rpm) (MPa)

2 7.5 (0.46)
14 14
3 10.2 (0.62)
4 12.8 (0.78)
5 18 (1.10)
6 19.2 (1.17)
7 22.9 (1.40) 16
SQPV1 21 16 19
8 27 (1.67)
9 30 (1.85)
10 31 (1.89)
11 36 (2.22)
12 40 (2.49) 16
14
14 45 (2.78) 14
10 33 (2.01)
12 39 (2.47)
14 45 (2.78)
15 46.7 (2.85) 17.2 16
SQPV2 25 34.5
17 55 (3.39)
19 59.2 (3.61)
21 67 (4.13) 600 1800 1200 14 1500
25 78.6 (4.79) 14 14
17 53.3 (3.25)
21 66.7 (4.07)
25 81 (4.94)
30 97 (5.91) 17.2 16
SQPV3 35 44.5
32 100 (6.10)
35 112 (6.83)
38 121 (7.37)
42 134 (8.17) 14 14
30 96 (5.86)
35 109 (6.65)
38 128 (7.81)
42 138 (8.41) 17.2
16
SQPV4 45 147 (8.95) 59.5 84.5
50 162 (9.85)
60 193 (11.75)
67 210 (12.81) 16
75 236 (14.4) 14 14

Rated capacity in Usgpm an 1200rpm and 0.7 MPa.

34 www.dexco.com.br
www.dexcohydraulics.com
SQPV series double pump

F3 SQPV32 35 17 M F 1 CC 10 L

Port
Mounting Shaft Outlet Design
Refit Series Code connection Rotation
type type position number
thread

2, 3, 4,
10, 12,
5, 6, 7,
14, 15,
SQPV21 8, 9, 10,
17, 19,
11, 12,
21, 25
14

2, 3, 4,
17, 21,
5, 6, 7,
Omit using 25, 30,
SQPV31 8, 9, 10,
antiwear oil 32, 35,
11, 12, (viewed from
or phosphate 38, 42
14 Flange 1– shaft end of
ester fluid
M – Metric mounting, straight pump)
17, 21, 10, 12, thread omit keyed
25, 30, 14, 15,
SQPV32
32, 35, 17, 19,
38, 42 21, 25 Check
F11 - Using descriptio
10 L – left hand for
water glycol n on page
30, 35, 2, 3, 4, counterclockwise
fluid 47
38, 42, 5, 6, 7,
SQPV41 45, 50, 8, 9, 10, 86 –
60, 67, 11, 12, heavy
75 14 I – Inch duty
thread, omit F – Foot straight
30, 35, mounting keyed R – right hand for
F3 – Using 10, 12,
38, 42, clockwise
water in-oil 14, 15,
emulsions SQPV42 45, 50,
17, 19,
60, 67,
21, 25
75

30, 35,
17, 21,
38, 42,
25, 30,
SQPV43 45, 50,
32, 35,
60, 67,
38, 42
75

Rated capacity in Usgpm an 1200rpm and 0.7 MPa.

35 www.dexco.com.br
www.dexcohydraulics.com
Technical Data

Shaft end pump (No. 1 outlet) Cover and pump (No. 2 outlet)
Max. Min
Geometric Geometric Weight
Series Operating Operating Speed Speed
Code displacement Code displacement (Kg)
pressure (Mpa) pressure (Mpa) (rpm) (rpm)
mL/r in³/r mL/r in³/r
10 33 2.01
2 7.5 0.46 14
12 39 2.47
F3=7
14 45 2.78 F11=14
15 46.7 2.85 3 10.2 0.62
SQPV21
17 55 3.39 17.2
4 12.8 0.78 F3=7
19 59.2 3.61 F11=14
21 67 4.13
25 78.6 4.79 5 18 1.1

17 53.3 3.25
21 66.7 4.07 6 19.2 1.17
25 81 4.94 31.5
30 97 5.91 7 22.9 1.4
SQPV31
32 100 6.1 20.7
35 112 6.83 8 27 1.67 F3=6.9
38 121 7.37 F11=15.7

42 134 8.17 9 30 1.85


30 96 5.86
35 109 6.65
10 31 1.89
38 128 7.81
42 138 8.41
11 36 2.22
SQPV41 45 147 8.95
50 162 9.85 14
12 40 2.49 F3=7 46
60 193 11.75 F11=14
67 210 12.81 16
14 45 2.78 F3=7 74
75 236 14.4 17.2 F11=14 1800
F3=7 F3=1200 600
17 53.3 3.25
F11=16 F11=1500
21 66.7 4.07
25 81 4.94
30 97 5.91
SQPV32 48
32 100 6.1
35 112 6.83
10 33 2.01
38 121 7.37 12 39 2.47
42 134 8.17 14 45 2.78
17.2
15 46.7 2.85
30 96 5.86 F3=F7
17 55 3.39
35 109 6.65 F11=16
19 59.2 3.61
38 128 7.81 21 67 4.13
25 78.6 4.79
42 138 8.41
SQPV42 45 147 8.95 80
50 162 9.85
60 193 11.75
67 210 12.81
75 236 14.4
30 96 5.86
35 109 6.65
17 53.3 3.25
38 128 7.81 21 66.7 4.07
42 138 8.41 25 81 4.94
17.2
30 97 5.91
SQPV43 45 147 8.95 F3=F7 88.5
32 100 6.1
50 162 9.85 F11=F16
35 112 6.83
60 193 11.75 38 121 7.37
42 134 8.17
67 210 12.81
75 236 14.4

36 www.dexco.com.br
www.dexcohydraulics.com
Output flow and input power performance characteristic

Typical flow at 50°C (120°F), 26cSt (128SUS), 0MPa (0psi) inlet at rated speeds

Speed Output flow (L/min) Input power (KW)


Series
r/min 0.7MPa 7MPa 14MPa 17.2MPa 0.7MPa 7MPa 14MPa 17.2MPa
1000 7.5 6 4.5 0.2 1.2 2.1
1200 9.5 8.5 6.5 0.3 1.5 2.5
SQPV1-2
1500 11.2 9.3 7.5 0.3 1.8 3.2
1800 13.5 11.2 9.0 0.4 2.2 3.8
1000 10.2 8.8 7.4 0.3 1.5 3.1
1200 12.5 11.0 9.5 0.4 1.8 3.7
SQPV1-3
1500 15.3 13.7 12.1 0.5 2.3 4.7
1800 18.4 16.9 15.3 0.5 2.7 5.6
1000 12.8 12.3 10.8 10 0.4 1.8 3.7 4.6
1200 16.0 15.0 13.5 13.0 0.5 2.2 4.4 5.5
SQPV1-4
1500 19.2 17.7 16.2 15.7 0.6 2.7 5.6 6.9
1800 23.1 21.3 19.5 19.0 0.7 3.2 6.7 8.3
1000 16.7 15.7 14.7 14.2 0.4 2.8 4.8 6.0
1200 20.0 19.0 18.0 17.5 0.5 3.2 5.8 7.2
SQPV1-5
1500 25.0 24.0 23.0 22.5 0.6 3.9 7.3 9.0
1800 30.0 29.0 28.0 27.5 0.6 4.2 8.6 10.7
1000 19.2 18.2 17.0 16.2 0.4 3.0 5.5 6.6
1200 23.0 22.0 20.5 20.0 0.5 3.5 6.5 7.9
SQPV1-6
1500 28.5 27.5 26.0 25.0 0.6 4.3 8.1 9.8
1800 34.5 33.5 32.0 31.0 0.7 5.2 9.7 11.8
1000 22.9 21.4 19.9 18.9 0.5 3.4 6.2 7.6
1200 27.5 26.0 24.5 23.5 0.6 4.0 7.4 9.1
SQPV1-7
1500 34.4 32.9 31.4 30.4 0.7 5.0 9.2 11.3
1800 41.3 39.8 38.3 37.3 0.8 5.9 11.0 13.6
1000 26.2 24.2 22.7 21.2 0.5 3.9 6.7 8.3
1200 31.5 29.5 28.0 26.5 0.6 4.5 8.0 10.0
SQPV1-8
1500 39.4 37.4 35.9 34.4 0.8 5.5 10.0 12.5
1800 47.2 45.2 43.7 42.2 0.8 6.6 11.8 14.8
1000 28.8 26.8 25.3 23.8 0.5 4.2 7.0 8.6
1200 34.5 32.5 31.5 30.0 0.6 5.0 8.5 10.5
SQPV1-9
1500 43.2 41.2 39.7 38.2 0.8 5.9 10.4 12.9
1800 51.8 49.8 48.3 46.8 0.9 7.1 12.3 15.3
1000 31 29.2 26.5 24.8 0.6 4.6 8.4 10.4
1200 37.2 34.7 32.4 30.9 0.7 5.4 10.0 12.5
SQPV1-10
1500 46.5 43.1 41.3 39.4 0.9 6.5 12.5 15.6
1800 55.8 53.2 50.6 48.5 0.9 7.8 14.7 18.5
1000 35 33.0 30.5 29.5 0.7 4.9 9.2 11.4
1200 42.0 40.0 37.5 36.5 0.8 5.7 11.0 13.7
SQPV1-11
1500 52.5 50.5 48.0 47.0 1.0 6.9 13.8 17.1
1800 63.5 61.0 58.5 57.5 1.0 8.3 16.2 20.3
1000 37.9 36.4 34.4 0.7 5.6 10.4
1200 45.5 44.0 42.0 0.9 6.5 12.5
SQPV1-12
1500 56.9 55.4 53.4 1.1 7.9 15.6
1800 68.2 66.7 64.7 1.1 9.4 18.4
1000 44.2 42.7 40.7 1.0 6.6 12.2
1200 53.0 51.5 49.5 1.1 7.8 14.6
SQPV1-14
1500 66.0 64.0 62.0 1.3 9.6 18.2
1800 79.5 77.5 75.5 1.4 11.5 21.7

37 www.dexco.com.br
www.dexcohydraulics.com
Speed Output flow (L/min) Input power (KW)
Series
r/min 0.7MPa 7MPa 14MPa 17.2MPa 0.7MPa 7MPa 14MPa 17.2MPa
1000 32.5 29.5 26.0 24.5 0.9 4.9 9.3 11.3
1200 39.0 36.0 32.5 31.0 1.0 5.8 11.1 13.5
SQPV2-10
1500 48.8 45.8 42.3 40.8 1.2 7.2 13.8 16.8
1800 58.5 55.5 52.0 5.05 1.3 8.5 16.5 20.1
1000 38.3 35.9 26.0 31.8 1.0 5.7 10.9 13.4
1200 46.0 43.6 32.5 39.5 1.1 6.5 13.0 16.0
SQPV2-12
1500 57.5 55.1 42.3 51.0 1.3 8.3 16.1 19.9
1800 69.0 66.6 52.0 62.5 1.4 9.8 19.3 23.8
1000 43.3 40.2 33.3 35.8 1.2 6.4 12.2 15.1
1200 52.0 48.5 41.0 44.5 1.3 7.5 14.5 18.0
SQPV2-14
1500 65.0 61.9 52.5 57.5 1.5 9.4 18.0 22.4
1800 78.0 74.9 64.0 70.5 1.7 11.1 21.5 26.7
1000 46.7 43.7 40.7 39.2 1.2 6.8 13.0 15.9
1200 56.0 53.0 50.0 48.5 1.3 8.0 15.5 19.0
SQPV2-15
1500 70.0 67.0 64.0 62.5 1.5 9.9 19.3 23.6
1800 84.0 81.0 7.8 76.5 1.7 11.8 23.0 28.3
1000 52.5 49.7 46.5 44.5 1.4 8.5 14.3
1200 63.0 60.6 57.0 55.0 1.5 7.4 17.0 17.6
SQPV2-17
1500 78.8 76.0 72.8 7.08 1.7 9.0 21.1 21.0
1800 94.5 91.7 88.5 86.5 1.9 10.8 25.1 26.1
1000 59.2 56.2 53.2 50.2 1.5 8.5 16.0 20.1
1200 71.0 68.0 65.0 62 1.7 10.0 19.0 24.0
SQPV2-19
1500 88.7 85.7 82.7 79.7 1.9 12.3 24.1 29.8
1800 106.5 103.7 100.7 97.7 2.2 14.7 28.2 35.7
1000 65.0 62.2 59.0 57.0 1.6 12.9 17.6 31.2
1200 78.0 75.0 72.0 70.0 1.8 9.2 21.0 21.8
SQPV2-21
1500 97.5 94.7 91.5 89.5 2.1 11.0 26.1 26.0
1800 117 114 111 109 2.3 13.4 31.1 32.3
1000 78.8 74.8 71.5 2.0 11.2 21.4
1200 94.6 90.3 87.8 2.2 13.4 25.6
SQPV2-25
1500 118.2 113.0 110.0 2.6 16.3 31.8
1800 141.0 137.0 134.0 2.8 19.5 32.4
1000 53.3 47.3 41.3 38.3 1.4 6.8 12.6 15.5
1200 64.0 58.0 52.0 49.4 1.5 8.0 15.0 18.5
SQPV3-17
1500 80.0 74.0 68.0 65.0 1.7 9.8 18.6 22.9
1800 96.0 90.0 84.0 81.0 1.9 11.6 22.1 27.4
1000 66.7 60.7 54.7 51.7 1.6 8.9 16.8 20.6
1200 80.0 74 68 65.0 1.8 10.5 20.0 24.5
SQPV3-21
1500 100 94 88 85.0 2.0 12.9 24.8 30.4
1800 120.4 114 108 105.0 2.3 15.4 30.5 36.4
1000 79.2 73.5 67.2 64.2 1.8 10.7 20.5 25.1
1200 95.0 89.0 83.0 80.0 2.0 12.5 24.5 30.0
SQPV3-25
1500 119 113 107.0 104.0 2.3 15.7 30.4 3.3
1800 142 136 130.0 127.0 2.6 18.7 36.4 4.6
1000 95.0 88.4 81.0 78.0 1.8 12.6 24.7 30.5
1200 114 107 100 97.0 2.0 15.0 29.5 36.5
SQPV3-30
1500 142 136 128 125 2.4 18.6 36.7 45.5
1800 171 164 157 154 2.7 22.2 44 54.5

38 www.dexco.com.br
www.dexcohydraulics.com
Speed Output flow (L/min) Input power (KW)
Series
r/min 0.7MPa 7MPa 14MPa 17.2MPa 0.7MPa 7MPa 14MPa 17.2MPa
1000 100 92 85 82 2.1 13.5 26.0 32.2
1200 120 112 105 102 2.3 16.0 31.0 38.5
SQPV3-32
1500 150 142 135 132 2.7 19.8 38.6 47.9
1800 180 172 165 162 3.1 23.6 46.1 57.4
1000 109 103 95.2 114 2.2 1.2 27.6 34.3
1200 131 124 117 147 2.5 17.0 33.0 41.0
SQPV3-35
1500 64 157 150 179 2.9 20.9 41.0 51.0
1800 196 189 182 99.3 3.3 24.9 50.4 61.1
1000 118 111 102 123 2.7 15.5 29.8 36.9
1200 142 134 126 158 3.0 18.5 35.5 44.0
SQPV3-38
1500 177 170 161 196 3.4 22.7 44.0 54.7
1800 213 205 197 3.9 27.0 52.6 65.4
1000 134 125 118 4.5 27.1 52.1
1200 160 152 144 5.0 32.2 62.2
SQPV3-42
1500 201 193 185 5.8 39.8 77.4
1800 241 233 225 6.6 47.5 92.5
1000 96.0 89 77 72 1.6 13.4 25.1 30.9
1200 115 106 96 91 2.0 15.0 30.0 370
SQPV4-30
1500 144 135 125 120 2.4 18.6 37.4 46.1
1800 172.5 163.5 153.5 148.5 2.8 22.3 44.7 55.2
1000 109 100 90 85 1.7 14.2 26.4 35.1
1200 131 122 112 107 2.0 17.0 34.0 42.0
SQPV4-35
1500 164 157 148.7 140 2.4 21.2 42.4 52.4
1800 196.5 187.5 177.5 172.5 2.9 25.4 50.9 62.9
1000 128 119 109 104 2.7 16.8 33.5 41.0
1200 154 145 135 130 3.0 20.0 40.0 49.0
SQPV4-38
1500 192.5 183.5 173.5 168.5 3.5 24.8 49.8 61.0
1800 231 222 212 207 4.0 29.5 59.5 73.0
1000 134 125 115 110 2.7 17.7 35.2 43.5
1200 161 152 142 137 3.0 21.0 42.0 52.0
SQPV4-42
1500 201 192 182 177 3.5 26.0 52.3 64.7
1800 241 232 222 217 4.0 31.0 62.5 77.5
1000 140 131 121 116 2.9 17.9 35.4 43.7
1200 168 159 149 144 3.2 21.2 42.2 52.2
SQPV4-45
1500 210 201 190 185 3.7 26.2 53.5 64.9
1800 252 243 233 228 4.2 31.2 62.7 77.7
1000 156 147 137 132 3.1 20.2 39.4 49.3
1200 187 178 168 163 3.5 24.0 47.0 59.0
SQPV4-50
1500 234 225 215 210 4.0 29.7 58.5 73.4
1800 280 271 261 256 4.7 35.4 69.9 87.9
1000 198 178 166 160 4.0 24.4 46.9 58.6
1200 227 216 204 198 4.5 29.0 56.0 70.0
SQPV4-60
1500 284 273 261 255 5.2 35.8 69.9 87.1
1800 340 329 317 311 5.9 42.7 83.2 104
1000 210 199 187 4.5 29.1 52.1
1200 252 241 229 5.0 32.2 62.2
SQPV4-67
1500 315 304 292 5.8 39.8 77.4
1800 378 366 354 6.6 47.5 92.5
1000 236 225 213 5.0 30.5 58.7
1200 289 238 266 5.6 36.5 70
SQPV4-75
1500 354 343 331 6.5 44.8 87
1800 424 414 402 7.4 53.4 104

39 www.dexco.com.br
www.dexcohydraulics.com
Noise characteristic

Conditions: ISO VG3 (50°C) 0MPa inlet, distance: 1mm.

40 www.dexco.com.br
www.dexcohydraulics.com
Configuration and installation dimension (mm)

41 www.dexco.com.br
www.dexcohydraulics.com
42 www.dexco.com.br
www.dexcohydraulics.com
43 www.dexco.com.br
www.dexcohydraulics.com
44 www.dexco.com.br
www.dexcohydraulics.com
45 www.dexco.com.br
www.dexcohydraulics.com
SQPV series cartridge kits

1 2 3 4 5 6
CK - SQPV2 - 21 R B - 10

1 2 3 4 5 6

SQPV1
Rotation
(view from smaller end)
SQPV2
CK
Displacement code B – no bush, omit if not required 10 – design number
Cartridge Kits L – left hand for counter clockwise
SQPV3
R – right hand for clockwise, omit
SQPV4

Series Code

SQPV1 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14


SQPV2 10, 12, 14, 15, 17, 19, 21, 25
SQPV3 17, 21, 25, 30, 32, 35, 38, 42
SQPV4 30, 35, 38, 42, 45, 50, 60, 67, 75

Model øA øB øC øD L M N P H X Y Z

SQPV1 82.5 76.2 47.1 4.8 81.3 70.5 64.5 73.66 6 2-222 76.76x3x3.5 2-236
SQPV2 96.8 90.5 52.2 4.8 98.7 86.6 77.6 88.18 7 2-224 91x3x3.5 2-241
SQPV3 114.3 108 72.1 6.4 117.2 104.5 90.8 103.94 7 2-230 108.5x3x3.5 2-247
SQPV4 133.3 127 80.1 6.4 140.4 119 105.6 123.8 8 2-233 127.6x3x3.5 2-253

46 www.dexco.com.br
www.dexcohydraulics.com
Outlet position

(Viewed from cover end of pump)


No. 1 outlet as that of shaft end of pump no. 2 outlet as that of cover end of pump.

All series except H2525V and H4535V (Q) SQPV43 Series H2525V and H4535V (Q) SQPV3

With no. 1 outlet opposite inlet With no. 1 outlet opposite inlet
AA – No. 2 outlet 135° CCW from inlet AA – No. 2 outlet opposite inlet
AB – No. 2 outlet 45° CCW from inlet AB – No. 2 outlet 90° CCW from inlet
AC – No. 2 outlet 45° CW from inlet AC – No. 2 outlet in line with inlet
AD – No. 2 outlet 135° CW from inlet AD – No. 2 outlet 90° CW from inlet
With no. 1 outlet 90° CCW from inlet With no. 1 outlet 90° CCW from inlet
BA – No. 2 outlet 135° CCW from inlet BA – No. 2 outlet opposite inlet
BB – No. 2 outlet 45° CCW from inlet BB – No. 2 outlet 90° CCW from inlet
BC – No. 2 outlet 45° CW from inlet BC – No. 2 outlet in line with inlet
BD – No. 2 outlet 135° CW from inlet BD – No. 2 outlet 90° CW from inlet
With no. 1 outlet in line with inlet With no. 1 outlet in line with inlet
CA – No. 2 outlet 135° CCW from inlet CA – No. 2 outlet opposite inlet
CB – No. 2 outlet 45° CCW from inlet CB – No. 2 outlet 90° CCW from inlet
CC – No. 2 outlet 45° CW from inlet CC – No. 2 outlet in line with inlet
CD – No. 2 outlet 135° CW from inlet CD – No. 2 outlet 90° CW from inlet
With no. 1 outlet 90° CW from inlet With no. 1 outlet 90° CW from inlet
DA – No. 2 outlet 135° CCW from inlet DA – No. 2 outlet opposite inlet
DB – No. 2 outlet 45° CCW from inlet DB – No. 2 outlet 90° CCW from inlet
DC – No. 2 outlet 45° CW from inlet DC – No. 2 outlet in line with inlet
DD – No. 2 outlet 135° CW from inlet DD – No. 2 outlet 90° CW from inlet

47 www.dexco.com.br
www.dexcohydraulics.com
Straight key shaft type

Model Shaft code A B C øD E F (key) width x length

20V
22.225 24.5
20VQ 1 58.7 9.53 12.1 4.76 x 32
22.200 24.4
SQPV1

22.225 24.5
1 59 9.53 11.1 4.76 x 32
25V 22.200 24.4
25VQ
SQPV2 25.370 28.3
86 77.7 9.53 11.1 6.36 x 50.8
25.345 28.1

31.75 35.30
1 73.2 9.53 11.1 7.94 x 38.1
35V 31.70 35.05
35VQ
SQPV3 34.90 38.6
86 85.9 9.53 11.1 7.94 x 54
34.85 38.3

31.75 35.30
1 62 12.7 14.22 7.94 x 28.5
45V 31.70 35.05
45VQ
SQPV4 38.07 42.4
86 87.4 12.7 14.22 9.53 x 50.8
38.02 42.1

48 www.dexco.com.br
www.dexcohydraulics.com
Splined key shaft type

Spline data reference


Shaft
Pump series A B C D øE Number Major Form Minor Suitable
code Pitch
of teeth diameter diameter diameter for

20V 20VQ 151 41.1 9.53 11.1 3.9 27.8 13 16/32 21.8~21.6 19.03 18.16

25V 25VQ 30VQ


2520V 2520VQ 11 44.5 9.53 11.1 4.1 27.8 13 16/32 21.8~21.6 19.03 18.16
3020VQ

2520VQ
123 44.5 9.53 15.7 4.1 27.8 14 16/32 21.8~21.6 19.03 18.16
3020VQ Side fit

2525V 174 59.9 9.53 17.3 3.0 29.2 14 12/24 31.2~31.1 27.4 26.42
35V 35V Q 11 58.7 9.53 11.1 6.35 35.1 14 12/24 31.2~31.1 27.4 26.42
35VQ 123 58.7 9.53 15.2 5.5 35.1 14 12/24 31.2~31.1 27.4 26.42
45V 45VQ 11 61.9 12.7 14.3 9.7 39.6 14 12/24 31.2~31.1 27.4 26.42
45VQ 130 61.9 12.7 15.2 9.9 40.4 14 12/24 31.2~31.1 27.4 26.42

49 www.dexco.com.br
www.dexcohydraulics.com
Port flange kits

Model Code:

Example: - - -

1. F - Flange
2. 06 – Size Code
3. A – Type of connection
A – Thread connection
B – For pipe socket welding
4. M – Bost type
M – Metric
I – Inch
5. Design number

Dimension O’ring
Port Pipe Weight
Type GB345,
connection size kg
C D E F H J K L N Q T 21-82

F-04-A 25 15 1/2" - - 21.1x2.6


1/2”NPT 1/2" 40 54 17.5 38.1 8.8 13 0.5
F-04-B 8 12 - 11 22.2 5
F-06-A 3/4" - -
3/4”NPT 3/4” 48 65 22.2 47.6 11 28 17 19.1 30x2.65 0.7
F-06-B - 12 27.7
F-08-A 1” - - 35.5x2.6
1”NPT 1” 55 70 26.2 52.4 11 28 17 25.4 0.9
F-08-B - 14 34.5 5
F-10-A 18 1.1/4” - -
1.1/4”NPT 1.1/4” 64 80 30.2 58.7 11 30 31.8 40x26.5 1.2
F-10-B 20 - 18 43.2
F-12-A 18 1.1/2” - -
1.1/2”NPT 1.1/2” 72 94 35.7 69.9 13.5 30 38.1 50x3.55 1.5
F-12-B 20 - 18 49.1
F-16-A 18 2” - -
- 2” 85 102 42.9 77.8 13.5 30 50.8 65x3.55 1.5
F-16-B 20 - 20 61.1
F-20-A 19 2.1/2” - -
- 2.1/2” 102 114 50.8 88.9 13.5 38 63.5 75x3.55 1.5
F-20-B 17 - 22 77.1
F-24-A 53 3 - -
- 3” 116 135 62 106.4 17.5 17 76.2 85x3.55 2.7
F-24-B 38 - 25 90
F-28-A 53 3.1/2” - -
- 3.1/2 134 153 69.9 120.6 17.5 17 88.9 100x3.55 3.4
F-28-B 38 - 28 102.8
F-32-A 53 4 - -
- 4” 150 162 77.8 130.2 17.5 17 101.6 115x3.55 3.7
F-32-B 38 - 28 115.5

50 www.dexco.com.br
www.dexcohydraulics.com
Port flange kits

Port flange kits and fixings for single pumps

Model Inlet port Outlet port

Port flange model F-12-A-10 (F-12-B-10) F-06-A-10 (F-06-B-10)


Tapped hole size x hole depth 1/2”-13UNC-21 or M12-21 3/8”-16UNC-19 or M10-19
20V(Q)
1/2"-13-UNC-40 or M12-40 3/8”-16UNC-35 or M10-35
Screw specification (1/2"-13-UNC-50 or M12-50) (3/8”-16UNC-45 or M10-45)

Port flange model F-12-A-10 (F-12-B-10) F-08-A-10 (F-08-B-10)


25V(Q) Tapped hole size x hole depth 1/2”-13UNC-23.8 or M12-23.8 3/8”-16UNC-19 or M10-19
30V(Q) 1/2"-13-UNC-40 or M12-40 3/8”-16UNC-35 or M10-35
Screw specification (1/2"-13-UNC-50 or M12-50) (3/8”-16UNC-45 or M10-45)

Port flange model F-16-A-10 (F-16-B-10) F-10-A-10 (F-10-B-10)


Tapped hole size x hole depth 1/2”-13UNC-23.8 or M12-23.8 7/16”-14UNC-22.3 or M12-22.3
35VQ
1/2"-13-UNC-40 or M12-40 7/16”-14UNC-40 or M12-40
Screw specification (1/2"-13-UNC-50 or M12-50) (7/16”-14UNC-50 or M12-50)

Port flange model F-24-A-10 (F-24-B-10) F-12-A-10 (F-12-B-10)


Tapped hole size x hole depth 5/8”-11UNC-30 or M16-30 1/2”-11UNC-22.8 or M12-30
45V (Q)
5/8”-11UNC-70 or M16-70 1/2"-11-UNC-40 or M12-40
Screw specification (5/8”-11UNC-55 or M16-55) (1/2"-11-UNC-50 or M12-50)

Port flange kits and fixings for double pumps

Model Inlet port No.1 Outlet port No.2 Outlet port

Port flange model F-20-A-10 (F-20-B-10) F-08-A-10 (F-08-B-10) F-12-A-10 (F-12-B-10)


2520V (Q) Tapped hole size x 1/2”-13UNC-23.8 or M12-23.8 3/8”-16UNC-19 or M10-19 1/2”-13UNC-23.8 or M12-23.8
3020VQ hole depth
SQPV21 1/2”-13UNC-45 or M12-45 3/8”-16UNC-35 or M10-35 1/2"-13-UNC-40 or M12-40
Screw specification (1/2”-13UNC-55 or M12-55) (3/8”-16UNC-45 or M10-45) (1/2"-13-UNC-50 or M12-50)

Port flange model F-20-A-10 (F-20-B-10) F-08-A-10 (F-08-B-10) F-08-A-10 (F-08-B-10)


Tapped hole size x 1/2”-13UNC-23.8 or M12-23.8 3/8”-16UNC-19 or M10-19 3/8”-16UNC-19 or M10-19
2525V hole depth
1/2”-13UNC-45 or M12-45 3/8”-16UNC-35 or M10-35 3/8”-16UNC-35 or M10-35
Screw specification (1/2”-13UNC-55 or M12-55) (3/8”-16UNC-45 or M10-45) (3/8”-16UNC-45 or M10-45)

Port flange model F-24-A-10 (F-24-B-10) F-10-A-10 (F-10-B-10) F-06-A-10 (F-06-B-10)


Tapped hole size x 5/8”-11UNC-30 or M16-30 7/16”-14UNC-22.3 or M12-22.3 3/8”-16UNC-19 or M10-19
2520V (Q)
hole depth
SQPV31 5/8”-11UNC-70 or M16-70 7/16”-14UNC-40 or M12-40 3/8”-16UNC-35 or M10-35
Screw specification (5/8”-11UNC-55 or M16-55) (7/16”-14UNC-50 or M12-50) (3/8”-16UNC-45 or M10-45)

Port flange model F-24-A-10 (F-24-B-10) F-10-A-10 (F-10-B-10) F-08-A-10 (F-08-B-10)


3525V (Q) Tapped hole size x 5/8”-11UNC-30 or M16-30 7/16”-14UNC-22.3 or M12-22.3 3/8”-16UNC-19 or M10-19
3530VQ hole depth
SQPV32 5/8”-11UNC-70 or M16-70 7/16”-14UNC-40 or M12-40 3/8”-16UNC-35 or M10-35
Screw specification (5/8”-11UNC-55 or M16-55) (7/16”-14UNC-50 or M12-50) (3/8”-16UNC-45 or M10-45)

Port flange model F-28-A-10 (F-28-B-10) F-12-A-10 (F-12-B-10) F-06-A-10 (F-06-B-10)


Tapped hole size x 5/8”-11UNC-30 or M16-30 1/2”-13UNC-23.8 or M12-23.8 3/8”-16UNC-19 or M10-19
4520V (Q)
hole depth
SQPV41 5/8”-11UNC-70 or M16-70 1/2"-13-UNC-40 or M12-40 3/8”-16UNC-35 or M10-35
Screw specification (5/8”-11UNC-55 or M16-55) (1/2"-13-UNC-50 or M12-50) (3/8”-16UNC-45 or M10-45)

Port flange model F-28-A-10 (F-28-B-10) F-12-A-10 (F-12-B-10) F-08-A-10 (F-08-B-10)


4525V (Q) Tapped hole size x 5/8”-11UNC-30 or M16-30 1/2”-13UNC-23.8 or M12-23.8 3/8”-16UNC-19 or M10-19
4530VQ hole depth
SQPV42 5/8”-11UNC-70 or M16-70 1/2"-13-UNC-40 or M12-40 3/8”-16UNC-35 or M10-35
Screw specification (5/8”-11UNC-55 or M16-55) (1/2"-13-UNC-50 or M12-50) (3/8”-16UNC-45 or M10-45)

Port flange model F-32-A-10 (F-32-B-10) F-12-A-10 (F-12-B-10) F-10-A-10 (F-10-B-10)


Tapped hole size x 5/8”-11UNC-30 or M16-30 1/2”-13UNC-23.8 or M12-23.8 7/16”-14UNC-22.3 or M12-22.3
4535V (Q)
hole depth
SQPV43 5/8”-11UNC-70 or M16-70 1/2"-13-UNC-40 or M12-40 7/16”-14UNC-40 or M12-40
Screw specification (5/8”-11UNC-55 or M16-55) (1/2"-13-UNC-50 or M12-50) (7/16”-14UNC-50 or M12-50)

51 www.dexco.com.br
www.dexcohydraulics.com
Foot mounting bracket options for port

Type A B C D E F G H J K øL ØL1 øN øP RQ R

FB-A-10 171 178 92 181 93 98 17.4 13 146 50.8 101.6 11.1 146 1/2"-13UNC 51 13
FB-B-10 265 212 109.5 216 129 164 19 16 235 76.2 127 17.5 181 3/8"-11UNC 64 19
FB-C-10 172 178 92.1 181.1 96 99 17 13 146 50.8 101.6 11.1 146 1/2"-13UNC 51 20
FB-D-10 290 213 109.5 216 170 163 25 23 250 95 127 20.6 181 5/8"-11UNC 64 25

52 www.dexco.com.br
www.dexcohydraulics.com