DIRECTIONAL CONTROLS

EIC-E-1006-0
■ Cam Operated Directional Valves
These valves may be used to shift the direction of oil flow by depressing the spool by way of a cam.

■ Specifications
Max. Operating Max. T-line
Max. Flow Mass
Model Numbers Pressure Pressure
L/min Kg
Kgf/cm2 Kgf/cm2
DCG-01-2B※-40 30 210 70 1.1
DCG-03-2B※-50 100 250 100 3.8

Max. flow indicates the celling flow which does not affect the normal function (changeover) of valves.
■ Model Number Designation
E
F- DC G -01 -2 B 2 -R -40

Cam Operated Directional


No. of
Special Series Type of Valve Spool-Spring Spool Design
Valve Roller
Seals Number Connection Size Arrangement Type Number
Positions Position

Valves
None Y
F:
Special 01
(Normal
Position) R
(DC -01 ※ 40
DC: only)
Seals for
Cam
Phosphate G:
Operated B:
Ester Type Sub-Plate 2 2·3·8
Direc- Spring Offset
Fluids Mounting
tional
(Omit if
Valve Mounting Surface
not 03 50
required)

■ Sub-plates
Sub-plates are available. Specify Sub-Plate model from the table above.
When Sub-plates are not used, the mounting surface should have a good machined finish.
Sub-plates are sharable with DSG-01 (EIC-E-1001, page – 358) and DSG-03 (EIC-E-1002-0, page – 370).
See each pages for dimensional drawings.

■ Mounting Bolts
Socket head – cap screws in the table below are included.
Model Mounting Bolt
Socket Head Cap Screw Qty.
Numbers Ordering Code
DCG-01 M5 x 45 Lg. 4 BKDCG-01-40
DCG-03 M6 x35 Lg. 4 BKDCG-03-50

Cam Operated Directional Valves


401
DIRECTIONAL CONTROLS

■ Direction of Oil Flow for Roller position


Model Graphic Symbols
Roller Position and Direction of Oil Flow
Roller Stroke from Offset Position mm
■ Instructions
Numbers
Extend (Offset) Depressed Valve Type “2B8”
P B All Ports
A B
A T blocked
P
B
A
T
Tank port “T” functions as a drain port.
DCG-01-2B2 Directly connect it to the reservoir.
0 3.8 4.6 9.5
P T
[Max. allowable back pressure
A B P
A
B
T All ports open P
B
A
T 3.5 Kgf/cm2]
DCG-01-2B3
0 3.8 4.6 9.5
P T
Actuation force
A B P B P A
A&T ports blocked B&T ports blocked
DCG-01-2B8 Kg
0 3.8 9.5
P T

Actuation Force
20.4
A B P A All Ports P B
B T blocked A T 15.3
DCG-03-2B2
P T
0 3.4 3.8 7 10.2

A B
P A P B 5.1 Force
B T All ports open A T
DCG-03-2B3 0
0 3.0 4.0 7 0 25 50 75 100 Kgf/cm²
P T

A B
P A All Ports P B T-Line Back Pressure
B&T ports blocked blocked A&T ports blocked
DCG-03-2B8
0 3.6 4.7 7
P T

■ Pressure Drop Model Numbers


P→A
Pressure Drop Curve No.
B→T P→B A→T
DCG-01 DCG-01-2B2
Kgf/cm² 2 2 3 3
DCG-01-2B3
12
--
DCG-01-2B8 3 -- 3
Pressure Drop ∆P

10 1
8 2

6 3

4
2
0
0 10 20 L/min. 30
Flow Rate
For any viscosity, multiply the factors in the table below.
Viscosity cSt 15 20 30 40 50 60 70 80 90 100
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30

For any other specific gravity (G'), the pressure drop


( P') may be obtained from the formula below
P' = P (G'/G) where, P is the value on the above
chart and G is 0.85

DCG-03
Same as DSG-03 Series Solenoid Operated Directional Valves (Standard Type). See EIC-E-1002, Page-367.

Cam Operated Directional Valves


402
DIRECTIONAL CONTROLS
Mounting Surface :ISO 4401-AB-03-4-A
DCG-01-2B - -40 Pressure Port "P"
35.5 40.5

7.8
0.75
Cylinder Port "B" 28.5

32.5
8.5

31

48
55.8

15.5
Cylinder Port "A"
53 5.5 Dia. x Thru.
17 Dia. Roller 9.5 Dia. Spotface
Fully Extended 110 Cam and Roller Travel
4 Places Height of Cam
Position "Y" Ma
Tank Port "T" 9.5 x. 5

Normal Position
Position "R"

66 (Max)
50
38
Cam

25
13.5 Stroke
65
9.5 0.9 over Travel
Mounting Surface Extended Depressed

Note : 1. For the valve mounting surface dimensions, see the sub-plate dimensional drawing for DSG-01
(O-Ring Furnished) (Offset)
E
Series Solenoid Operated Directional Control Valve.

Cam Operated Directional


Mounting Surface :ISO 4401-AC-05-4-A
DCG-03-2B - -50

Valves
Finishing Dimensions of
Cylinder Port "B" Flow Restrictor
Pressure Port "P" 7 Dia. x Thru.
11 Dia. Spotface 10.984
Cylinder Port "A"
4 Places
Max. R 0.2 10.966 Dia.
Alternate long and short 56.8 54 ("d")*
12

dash line indicates the 15°


1

Model DCG-03-2B -R.


5~10
46.2

46
70

1.1
1.2

* Orifice dia. “d” should be determined by


customer application.
18 Dia. Roller 73.3
Tank Port "T" Max.
Fully Extended 158.6 Height of Cam 30° Cam and Roller
7 Travel
2
6

59
35.3

Cam
27

19 Mounting Surface
92 7
(O-rings Furnished)
Depressed
1 Each port (P,A,B and T) is machined for flow restrictor. The flow restrictor 8.2
should be machined in accordance with the Finishing Dimensions for Flow Max. Stroke
Restrictor as shown in the right-hand drawing. Extended
2 Although the tank port is shown on the left in our sub-plate, either may be used. (Offset)
Notes :
1 For the valve mounting surface dimensions, see the sub-plate dimensional
drawing for DSG-03 Series Solenoid Operated Directional Valves.

Cam Operated Directional Valves


403
DIRECTIONAL CONTROLS

■ Spare Parts List


List of Seals List of Seal Kits
Sl. Qty. Model Numbers Seal Kit Numbers
Name of Part Part No.
No. DCG-01 DCG-03 DCG-01 KS-DCG-01-40
1 O-Ring SO-NA-P5 1 - DCG-03 KS-DCG-03-50
2 O-Ring SO-NB-P9 4 -
3 O-Ring SO-NB-P18 2 -
4 O-Ring SO-NB-P21 - 2
5 O-Ring SO-NA-P6 - 1
6 O-Ring AS568-A014 - 5
7 Back up Ring SO-BE-P6 - 1
8 Packing VK4-12280-0 1 -
Note : When ordering the seals, please specify the seal kit number from the table right.