Report No.: 23 Test Time: 2017/5/2 17:16

Luminaire Property
Luminaire Manufacturer:
Luminaire Description: WE-AR111-24°-12W Luminous Length (mm): 93
Luminous Width (mm): 93 Voltage: 220V
Current: 0.052 A Power: 11.49W
Power Factor: 0.995

Photometric Results
CIE Class: Direct Total Rated Lamp Lumens: 656.5 lm
Measurement Flux: 656.5 lm Efficiency: 100%
Downward Ratio: 98% Upward Ratio: 2%
Horizontal Diffuse Angle(50%): H25.2
Vertical Diffuse Angle(50%): V25.2
Luminaire Efficacy Rating (LER): 57 Central Intensity: 2851.5 cd
Max. Intensity: 3084.63 cd Pos of Max. Intensity: H0 V5

Picture Of Luminaire Luminous Intensity Distribution Curve

165 180 165


150 150
135 135

120 120

105 105

90 90
771
75 1542 75

60 2313 60

45 3084 45
30 3855 30
15 0 15

Unit: cd
Average Diffuse Angle(50%): 25.2°
C0-C180 C90-C270 G5

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 2 of 15 Pages

Luminous Intensity Distribution Curve

165 180 165


150 150
135 135

120 120

105 105

90 90
771
75 1542 75

60 2313 60

45 3084 45
30 3855 30
15 0 15

3855

3084

2313

1542

771

0
-180 -120 -60 0 60 120 180
C0-C180 C90-C270 Unit: cd
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0
Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 3 of 15 Pages

Luminous Intensity Distribution Curve(cd/klm)


180
165 165
150 150

135 135

120 120

105 105

90 90

1174

75 75
2349

60 3524 60

45 4698 45

30 30
5873
15 15
0
cd/klm η=100%
C0-C180
C90-C270

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 4 of 15 Pages

Coefficients Of Utilization - Zonal Cavity Method


RC 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0
RW 0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0
RCR RF = 0.2
0 119 119 119 119 116 116 116 116 110 110 110 105 105 105 101 101 101 98
1 114 112 110 109 112 110 108 107 106 104 103 102 101 100 98 97 97 95
2 111 107 104 101 108 105 102 100 102 100 98 99 97 95 96 94 93 92
3 107 102 99 96 105 101 98 95 98 96 93 96 94 92 93 92 90 89
4 104 98 94 91 102 97 94 91 95 92 89 93 90 88 91 89 87 86
5 101 95 91 88 99 94 90 87 92 89 86 90 88 85 89 86 85 83
6 98 92 87 84 96 91 87 84 89 86 83 88 85 83 87 84 82 81
7 95 89 84 81 94 88 84 81 87 83 81 86 83 80 84 82 80 79
8 93 86 82 79 91 85 81 79 84 81 78 83 80 78 82 80 78 77
9 90 83 79 77 89 83 79 77 82 79 76 81 78 76 80 78 76 75
10 88 81 77 75 87 81 77 74 80 77 74 79 76 74 79 76 74 73
Spacing Criteria (0-180): 0.44
Spacing Criteria (90-270): 0.43
Spacing Criteria (Diagonal): 0.43
N Curves of Luminaires vs Lighting Area
30
25
20

15

10
8
7 3
6 H=
12
H= Luminous Flux 5000 lm
5 8=H6=
5
H=H Maintain Factor 0.70
4 =10 Suspend Length 0.00m
H Work Height 0.80m
3 Average Lux 100 lx
Reflectivity(%)
Line Type
Ceil Wall Floor
70 50 30
2 2 3 4
10 2 3 4 5 6 7 8 910 2 3 4 5 6 7 8 910
A(sq.m)

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 5 of 15 Pages

Isocandela (rectangle)

80

60

40

20
Vertical(Deg)

154
463
617
771
3081542
2313
0 3085

-20

-40

-60

-80

-80 -60 -40 -20 0 20 40 60 80


Horizontal(Deg)

Imax (100%): 3085 cd

( 5%): 154 cd ( 10%): 308 cd


( 15%): 463 cd ( 20%): 617 cd
( 25%): 771 cd ( 50%): 1542 cd
( 75%): 2313 cd (100%): 3085 cd

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 6 of 15 Pages

IsoLux Plot

0
2

1
1
Horizontal(m)

2
3 6
0

15
1

5
5 4 3 2 1 0 1 2 3 4 5
Vertical(m)

Mounting Height: 10.0m Max Lux(100%): 30.5 lx


( 1%): 0.3 lx ( 2%): 0.6 lx
( 5%): 1.5 lx ( 10%): 3.0 lx
( 20%): 6.1 lx ( 50%): 15.2 lx
(100%): 30.5 lx (200%): 61.0 lx

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 7 of 15 Pages

Lum Limit Curve


Dazzle Quality Illuminance (lx)
1.15 A 2000 1000 500 <=300
1.50 B 2000 1000 500 <=300
1.85 C 2000 1000 500 <=300
2.20 D 2000 1000 500 <=300
2.55 E 2000 1000 500 <=300
a b c d e f g h

Gamma a b c d e f g h
85
8
6
75 4 a/hs
3
65 2

55

45
6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4
C90 C270 L(cd/sq.m)
Gamma a b c d e f g h
85
8
6
75 4 a/hs
3
65 2

55

45
6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4
C0 C180 L(cd/sq.m)

L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85
C0 4708 2774 1536 772 659 1288 1742 619 743
C90 744 635 542 472 457 409 541 806 862
C180 2096 1103 562 946 1652 1569 996 373 610
C270 652 534 431 345 304 314 415 679 610

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 8 of 15 Pages

Illuminance at a Distance

Dist(m) Enadir(lx) Dh/Dv_B(m) S_B(sq.m) Eav_B(lx)

2.0 712.88 0.89/0.89 0.7 373.83

3.0 316.83 1.34/1.34 1.5 166.15

4.0 178.22 1.79/1.79 2.6 93.46

5.0 114.06 2.23/2.23 4.1 59.81

6.0 79.21 2.68/2.68 5.9 41.54

8.0 44.55 3.57/3.57 10.5 23.36

10.0 28.51 4.47/4.46 16.4 14.95

12.0 19.80 5.36/5.36 23.6 10.38

14.0 14.55 6.25/6.25 32.1 7.63

Dh 15.0 12.67 6.70/6.70 36.8 6.65

Dv Beam Angle(B): H25.2 V25.2 Field Angle(F): H43.5 V43.6

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 9 of 15 Pages

Vertical IsoLux Plot

1 285
143
57
29

4
Vertical Height(m)

10

11
0 1 2 3 4 5 6 7 8 9 10
Horizontal distance(m)

Lowest(m): 1.0m Highest(m): 11.0m Max Lux: 2851.5 lx


( 1%): 28.5 lx ( 2%): 57.0 lx
( 5%): 142.6 lx ( 10%): 285.1 lx
( 20%): 570.3 lx ( 50%):1425.8 lx
(100%):2851.5 lx (200%):5703.0 lx

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
Page 10 of 15 Pages

Area Flux Table


Unit: lm
-90
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0
-80
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0
-70

Gamma Plane (°):0.0-180.0:1.0


0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.0
-60
0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.7 0.0
-50

Test Device: GPM-1800B


0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 1.1 0.0
-40
0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0 2.1 0.0

Distance: 8.082 m
-30
杭州创惠仪器有限公司(中山办事处)

0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.8 2.6 3.8 2.1 0.7 0.4 0.2 0.1 0.0 0.0 0.0 11.5 0.7
-20

Humidity: 58
0.0 0.0 0.1 0.1 0.2 0.5 1.0 5.2 21.4 30.5 16.0 3.3 0.8 0.4 0.1 0.0 0.0 0.0 79.4 67.8

Inspector:
-10
0.0 0.0 0.1 0.1 0.3 0.8 2.1 14.3 54.7 76.9 44.0 9.2 1.4 0.5 0.1 0.0 0.0 0.0 204.6194.4
Vertical plane

0
Fax:+86-760-88758975
Tel:+86-15813129368

0.0 0.0 0.1 0.1 0.3 0.8 2.3 15.7 60.1 83.1 46.9 9.9 1.4 0.5 0.1 0.0 0.0 0.0 221.5211.7
10
0.0 0.0 0.1 0.1 0.2 0.5 1.1 7.2 27.1 37.8 20.7 4.1 0.8 0.4 0.1 0.0 0.0 0.0 100.2 89.7
20
www.dcuu.com

0.0 0.0 0.1 0.1 0.1 0.2 0.4 1.2 4.4 6.2 3.2 0.8 0.4 0.2 0.1 0.0 0.0 0.0 17.5 5.2
30
0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.4 0.5 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0 2.4 0.0
40
0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 1.2 0.0
50

Test Lab: Inventfine instrument


0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.8 0.0
60

C Plane (°):0.0-360.0: 45.0


0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.0
70
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.0

Operator: Jacky tang


80
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0

Test Type: TYPE C


Temperature: 28
90
Flux(T) 0.0 0.1 0.6 0.7 1.5 3.8 7.9 45.5 171.6 239.7 134.1 28.9 6.0 2.8 1.0 0.5 0.2 0.0 645
Flux(E) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 32.5 163.6 232.4 125.6 15.5 0.0 0.0 0.0 0.0 0.0 0.0 570
Flux(T)
Flux(E)
-90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
Horizontal plane
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 11 of 15 Pages

The Average Illuminance Effective Figure


Flux Out: 326.61lm

2.0m 520.83/ 712.88lx 0.89m / 0.63sq.m

3.0m 231.48/ 316.83lx 1.34m / 1.41sq.m

4.0m 130.21/ 178.22lx 1.79m / 2.51sq.m

5.0m 83.33/ 114.06lx 2.23m / 3.92sq.m

6.0m 57.87/ 79.21lx 2.68m / 5.64sq.m

7.0m 42.52/ 58.19lx 3.13m / 7.68sq.m

8.0m 32.55/ 44.55lx 3.57m / 10.03sq.m

10.0m 20.83/ 28.51lx 4.47m / 15.68sq.m

12.0m 14.47/ 19.80lx 5.36m / 22.58sq.m

15.0m 9.26/ 12.67lx 6.70m / 35.27sq.m

Height Avg./Nadir. E Beam Angle:25.2° Diameter / Area

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 12 of 15 Pages

UGR Table

Reflectance:
Ceiling (cavity) 0.7 0.7 0.5 0.5 0.3 0.7 0.7 0.5 0.5 0.3
Wall 0.5 0.3 0.5 0.3 0.3 0.5 0.3 0.5 0.3 0.3
Reference plane 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2

Room dimensions Viewed crosswise Viewed endwise

X=2H Y=2H 2.5 3.4 2.9 3.7 4.1 -0.9 -0.0 -0.5 0.3 0.7

3H 5.3 6.1 5.7 6.4 6.9 0.4 1.2 0.8 1.6 2.0

4H 7.2 7.9 7.6 8.3 8.7 1.3 2.0 1.7 2.4 2.8

6H 7.4 8.0 7.8 8.4 8.9 2.5 3.2 3.0 3.6 4.0

8H 7.5 8.1 7.9 8.5 9.0 3.5 4.1 4.0 4.6 5.0

12H 7.5 8.1 8.0 8.5 9.0 4.4 5.0 4.9 5.5 5.9

X=4H Y=2H 2.5 3.2 2.9 3.6 4.0 -0.3 0.4 0.1 0.8 1.2

3H 5.5 6.1 6.0 6.6 7.0 1.3 1.9 1.7 2.3 2.8

4H 7.6 8.1 8.1 8.6 9.1 2.4 2.9 2.8 3.4 3.9

6H 7.9 8.3 8.4 8.8 9.3 3.9 4.3 4.4 4.8 5.3

8H 8.1 8.5 8.6 9.0 9.5 5.0 5.4 5.5 5.9 6.4

12H 8.2 8.5 8.7 9.1 9.6 6.0 6.3 6.5 6.8 7.4

X=8H Y=4H 7.6 8.0 8.1 8.5 9.0 3.0 3.5 3.5 3.9 4.4

6H 8.0 8.4 8.6 8.9 9.4 4.8 5.1 5.3 5.6 6.2

8H 8.3 8.6 8.9 9.2 9.7 6.0 6.3 6.6 6.8 7.4

12H 8.6 8.8 9.1 9.4 10.0 7.1 7.4 7.7 7.9 8.5

X=12H Y=4H 7.6 7.9 8.1 8.4 9.0 3.1 3.5 3.6 4.0 4.5

6H 8.1 8.4 8.7 8.9 9.5 5.0 5.3 5.5 5.8 6.4

8H 8.5 8.7 9.0 9.3 9.9 6.3 6.5 6.8 7.1 7.7

Calculate in accordance with CIE 190:2010

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 13 of 15 Pages

Utilisation Factor Table(Floor cavity)

Utilisation Factors UF(F) SHR NOM = 0.50

Room Reflectance Room Index(RI)

Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00

0.70 0.50 0.20 0.95 0.99 1.03 1.05 1.08 1.10 1.11 1.13 1.14

0.30 0.91 0.96 0.99 1.01 1.05 1.07 1.09 1.11 1.12

0.20 0.89 0.93 0.96 0.99 1.03 1.05 1.07 1.09 1.11

0.50 0.50 0.20 0.94 0.98 1.00 1.02 1.05 1.06 1.07 1.09 1.10

0.30 0.90 0.95 0.97 0.99 1.02 1.04 1.05 1.07 1.08

0.20 0.88 0.92 0.95 0.97 1.00 1.02 1.04 1.06 1.07

0.30 0.50 0.20 0.92 0.96 0.98 1.00 1.02 1.03 1.04 1.05 1.06

0.30 0.90 0.93 0.96 0.98 1.00 1.01 1.02 1.04 1.05

0.20 0.88 0.91 0.94 0.96 0.98 1.00 1.01 1.03 1.04

0.00 0.00 0.00 0.86 0.89 0.92 0.93 0.95 0.96 0.97 0.98 0.99

Rating:0W Photometrically tested without ceiling board.


Multiply UF values by service correction factors
Calculate in accordance with CIBSE Technical Memorandum NO.5 1980

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 14 of 15 Pages

Utilisation Factor Table(Wall)

Utilisation Factors UF(W) SHR NOM = 0.50

Room Reflectance Room Index(RI)

Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00

0.70 0.50 0.20 0.46 0.38 0.32 0.28 0.22 0.18 0.16 0.12 0.10

0.30 0.38 0.32 0.28 0.24 0.20 0.17 0.14 0.11 0.09

0.20 0.33 0.28 0.25 0.22 0.18 0.15 0.13 0.11 0.09

0.50 0.50 0.20 0.43 0.35 0.29 0.25 0.20 0.21 0.14 0.11 0.09

0.30 0.36 0.30 0.26 0.23 0.18 0.15 0.13 0.10 0.08

0.20 0.32 0.27 0.23 0.20 0.17 0.14 0.12 0.10 0.08

0.30 0.50 0.20 0.40 0.32 0.27 0.23 0.18 0.15 0.13 0.10 0.08

0.30 0.35 0.28 0.24 0.21 0.17 0.14 0.12 0.09 0.08

0.20 0.30 0.25 0.22 0.19 0.15 0.13 0.11 0.09 0.07

0.00 0.00 0.00 0.15 0.12 0.10 0.08 0.06 0.05 0.04 0.03 0.03

Rating:0W Photometrically tested without ceiling board.


Multiply UF values by service correction factors
Calculate in accordance with CIBSE Technical Memorandum NO.5 1980

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector:
杭州创惠仪器有限公司(中山办事处)
www.dcuu.com
Tel:+86-15813129368
Fax:+86-760-88758975 Page 15 of 15 Pages

Utilisation Factor Table(Ceiling cavity)

Utilisation Factors UF(C) SHR NOM = 0.50

Room Reflectance Room Index(RI)

Ceiling Wall Floor 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00

0.70 0.50 0.20 0.14 0.15 0.17 0.18 0.19 0.20 0.21 0.22 0.23

0.30 0.10 0.12 0.14 0.15 0.17 0.18 0.19 0.21 0.21

0.20 0.08 0.10 0.12 0.13 0.15 0.17 0.18 0.19 0.20

0.50 0.50 0.20 0.13 0.15 0.16 0.17 0.19 0.19 0.20 0.21 0.22

0.30 0.10 0.12 0.14 0.15 0.17 0.18 0.19 0.20 0.21

0.20 0.08 0.10 0.12 0.13 0.15 0.16 0.17 0.19 0.20

0.30 0.50 0.20 0.13 0.14 0.16 0.16 0.18 0.19 0.19 0.20 0.21

0.30 0.10 0.12 0.13 0.15 0.16 0.17 0.18 0.19 0.20

0.20 0.08 0.10 0.12 0.13 0.15 0.16 0.17 0.18 0.19

0.00 0.00 0.00 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02

Rating:0W Photometrically tested without ceiling board.


Multiply UF values by service correction factors
Calculate in accordance with CIBSE Technical Memorandum NO.5 1980

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-180.0:1.0


Test Lab: Inventfine instrument Test Device: GPM-1800B
Test Type: TYPE C Distance: 8.082 m
Temperature: 28 Humidity: 58
Operator: Jacky tang Inspector: