This document summarizes the resistance and insulation test of proximity probes and extension cables used in a Bently Nevada vibration control system at the Sarir Oil Field gas treatment plant. The test procedure involves measuring the resistance of probe connectors, extension cable cores and jackets, and insulation resistance between probe/cable connectors and any ground. Resistance and insulation readings are recorded in a table for each probe and cable loop. The test was performed by instrumentation and automation engineer Faraj Almnfi.
This document summarizes the resistance and insulation test of proximity probes and extension cables used in a Bently Nevada vibration control system at the Sarir Oil Field gas treatment plant. The test procedure involves measuring the resistance of probe connectors, extension cable cores and jackets, and insulation resistance between probe/cable connectors and any ground. Resistance and insulation readings are recorded in a table for each probe and cable loop. The test was performed by instrumentation and automation engineer Faraj Almnfi.
This document summarizes the resistance and insulation test of proximity probes and extension cables used in a Bently Nevada vibration control system at the Sarir Oil Field gas treatment plant. The test procedure involves measuring the resistance of probe connectors, extension cable cores and jackets, and insulation resistance between probe/cable connectors and any ground. Resistance and insulation readings are recorded in a table for each probe and cable loop. The test was performed by instrumentation and automation engineer Faraj Almnfi.
Test title : Proximity probes and extension cables resistance and insulation test
System : BENTLY NEVADA vibration control system
location : SARIR OIL FIELD Plant : Gas treatment plant Unit : K221B turbine gas compressor Tools: FLUK multi meter Procedures:- 1- Disconnect proximity probe connector from extension cable and extension cable connectors from proximity sensor transducer 2- Measure proximity probe resistance between two points on the probe connector 3- Measure extension cable core resistance between two ends 4- Measure extension cable jacket resistance between two ends 5- Measure the insulation resistance between probe connector points and any ground on the body 6- Measure insulation resistance between extension cable connector points and any ground on the body 7- Carry out previous steps on all loops 8- Fill out the table as per measuring value for each loop
TAG No# ELEMENT RESISTANCE INSULATION Comments
Probe NDE CI-X1 Extension cable core Extension cable jackets Probe NDE CI-Y1 Extension cable core Extension cable jackets Probe DE CO-X1 Extension cable core Extension cable jackets Probe DE CO-Y1 Extension cable core Extension cable jackets
61-12 (PART 0) /issue 1 6 November 1992 Wires Cords and Cables Electrical - Metric Units Part 0:general Requirements and Test Methods For Qualification Approval