You are on page 1of 147

Atlas Copco

Oil-injected Rotary Screw Compressors


GA 30+-90/GA 37-90 VSD (30-90 kW/40-125 hp)
The ultimate smart solution, driven by efficiency
Atlas Copco’s GA 30+-90 compressors bring you outstanding sustainability, reliability and performance, while minimizing the total cost of

ownership. A choice of three premium compressor types (GA VSD, GA+ and GA) provides you with the compressed air solution that perfectly

matches your requirements with clear value propositions. Built to perform even in the harshest environments, these compressors keep your

production running efficiently.

New heights in sustainability


The GA 30+-90 family enables you to realize sustainable productivity
through lower lifecycle costs and maximum uptime. IE2 Premium
Efficiency motors in combination with the highly efficient element
minimize operating cost. The integrated dryer R410A reduces
ozone depletion and protects the environment. Maximum uptime
is achieved by maintenance from one side and complete drive
train accessibility.

New milestones in reliability


The reliability of the GA 30+-90 range starts with the cool
canopy and low element outlet temperatures, an
Benchmarking performance oversized separate oil cooler and an aftercooler with
Outstanding performance is ensured by design, with IE2 patented integrated mechanical separator. The three-
motors in combination with Atlas Copco’s highly efficient stage air/oil separation ensures low oil consumption. All
element and an oversized cooling arrangement resulting in electrical cubicles are in overpressure, preventing
significant energy savings. Internal pressure drops from inlet electrically conductive dust, thus increasing the lifetime
to discharge are optimized. Efficient smart compressor controls of electrical components.
and Atlas Copco algorithms minimize the working pressure
band, saving energy.
GA VSD: Ultimate energy saver
 Unique integrated Variable Speed Drive (VSD) technology for on average 35%
energy savings.
 Industry-leading operating turndown range and flexible pressure selection: 4-13 bar.
 Start under system pressure due to special VSD motor, no idling time.
 Integrated Dryer Saver Cycle saves up to 60% of the dryer’s electrical consumption.
 Smart Elektronikon® graphic compressor controller with high-definition color display
working to a set point minimizes pressure drops.

2 HIGH EFFICIENCY GA+: Industry-leading performance


IE
Industry-leading Free Air Delivery and low energy consumption.

IE2 High Efficiency motor in combination with efficient element.


Low noise emission suitable for workplace installation.


Environmentally-friendly R410A integrated dryer reduces footprint and


pressure drops.
Smart Elektronikon® graphic compressor controller with high-definition

color display.

GA: Premium compressor


High performance Free Air Delivery.

IE2 High Efficiency motor in combination with highly efficient element.


Premium quality at the lowest initial investment.


Efficient environmentally-friendly R410A integrated dryer reduces


footprint and pressure drops.


Ensured efficiency of Elektronikon® controller with connectivity.

VSD: Driving down your energy costs
Over 80% of a compressor’s lifecycle cost is taken up by the energy it consumes. Moreover, the generation of compressed

air can account for more than 40% of a plant’s total electricity bill. To cut your energy costs, Atlas Copco pioneered

Variable Speed Drive (VSD) technology in the compressed air industry. VSD leads to major energy savings, while protecting

the environment for future generations. Thanks to continual investments in this technology, Atlas Copco offers the widest

range of integrated VSD compressors on the market.

WHY ATLAS COPCO VARIABLE SPEED DRIVE TECHNOLOGY?


On average 35% energy savings during fluctuations in production demand with an extensive turndown range.

Integrated Elektronikon® Graphic controller controls the motor speed and high efficiency frequency inverter.

No wasted idling times or blow-off losses in normal operation.


Compressor can start/stop under full system pressure without the need to unload with special VSD motor.

Eliminates peak current penalty during start-up.


Minimizes system leakage due to a lower system pressure.


EMC Compliance to directives (2004/108/EG).


IME
NO IDLINGT
Air demand Energy consumption Air demand Energy consumption

Air demand Energy consumption Time Air demand GA VSD energy consumption Time
Fixed speed load/unload

In almost every production environment, air demand fluctuates depending on different factors such as the time of
the day, week or even month. Extensive measurements and studies of compressed air demand profiles show that
many compressors have substantial variations in air demand.

On average 35% energy savings

Atlas Copco’s GA VSD technology closely follows the air demand by


automatically adjusting the motor speed. This results in on average 35%
energy savings. The lifecycle cost of a compressor can be cut by an
average of 22%. In addition, lowered system pressure with GA VSD
dramatically minimizes energy use across your production.

Total compressor lifecycle cost


Energy Investment

Energy savings with VSD Maintenance


How GA VSD technology saves energy
Contact your local Atlas Copco representative for an audit of your compressed air system. A real-time measurement
simulation and audit report can be provided with recommendations for additional savings and sizing to meet your
compressed air needs.

AMPS STATUS OF GENERAL LOAD - NO LOAD COMPRESSOR

55.00
50.00

45.00

40.00
35.00

30.00

25.00
20.00

15.00

10.00
5.00 Unload and blow-off losses
Time

WHAT IS UNIQUE ABOUT THE INTEGRATED ATLAS COPCO GA VSD?


1 The Elektronikon® controls both the compressor 6 Mechanical enhancements ensure that all com-
and the integrated converter, ensuring maximum ponents operate below critical vibration levels
machine safety within parameters. throughout the entire compressor speed range.

2 Flexible pressure selection from 4 to 13 bar with 7 A highly efficient frequency converter in a cool
electronic gearing reduces electricity costs. overpressure cubicle ensures stable operation in high
ambient temperatures up to 50°C/122°F*.
3 Special electric motor specifically designed for VSD * Standard up to 46°C/114.8°F.
operation (inverter duty motor). Bearings are protected
against induced bearing currents. Both motor and 8 No ‘speed windows’ that can jeopardize the energy
converter are perfectly tuned for highest efficiency savings and the stable net pressure. Turndown
across the entire speed range. capability of the compressor is maximized to 80-85%.

4 Electric motor specifically designed for low 9 The cubicle cooling booster increases the lifetime of
operating speeds with clear attention to motor cooling electrical components due to a cool cubicle in
and compressor cooling requirements. overpressure and reduced dust ingress.

5 All Atlas Copco GA VSD compressors are EMC tested and 10 Net pressure band is maintained within 0.10 bar,
certified. External sources do not influence compressor 1.5 psi.
operation, nor does the compressor affect the operation of
other instruments via emissions or via the power supply line.

Operating range Non-integrated Atlas Copco Combined motor/converter efficiency


solution integrated solution

100%

minimum maximum minimum maximum


Flow Motor speed

Speed windows Non-integrated VSD Integrated VSD


High reliability and smart energy

1
Maintenance-free drive system
100% maintenance-free; totally enclosed and protected against dirt and dust.

Suitable for harsh environments.


High-efficiency drive arrangement; no coupling or slippage losses.


Standard up to 46˚C/115˚F and for high ambient version 55˚C/131˚F.


2
IE2 High Efficiency electrical motors
8
IP55, insulation Class F, B rise.

Non-drive side bearing greased for life.


Designed for continuous operation in harsh environments.


3
Robust spin-on oil filter
High-efficiency, removing 300% smaller particles

than a conventional filter.


Integrated bypass valve with the oil filter.

2
4
1
SIL Smart inlet lock system for
GA VSD compressors
Superior designed vacuum and air pressure controlled

valve with minimal pressure drop and no springs.


Smart stop/start which eliminates back-pressure oil vapor.

5
Separate oversized oil cooler
and aftercooler
Low element outlet temperatures, ensuring long oil lifetime.

Removal of nearly 100% condensate by mechanical separator.


No consumables.

Eliminates possibility of thermal shocks in coolers.



11
Cubicle cooling booster
Cubicle in overpressure minimizes ingress of conductive dust.

Electrical components remain cool, enhancing lifetime of components.


10
Integrated highly efficient
R410A dryer
 Excellence in air quality.
 50% reduction in energy consumption compared
to traditional dryers.
 Zero ozone depletion.
 Incorporates optional DD and PD filters according
to Class 1.4.1.

9
9
Elektronikon® for remote
monitoring
5
 Integrated smart algorithms reduce system pressure
and energy consumption.
 Monitoring features include warning indications,
maintenance scheduling and online
visualization of machine’s condition.

4
8
Heavy-duty air intake filter
 Protects the compressor components by removing
99.9% of dirt particles down to 3 microns.
3  Differential inlet pressure for proactive maintenance
while minimizing pressure drop.

7
Electronic no-loss water drain
(optional)
 Ensures constant removal of condensate.
6  Manual integrated bypass for effective condensate
removal in case of power failure.
Water separator device (WSD)  Integrated with compressor’s Elektronikon® with
High efficient.
 warning/alarm features.
Ensures constant removal of condensate.
  No loss of compressed air.
A step ahead in monitoring and controls
The next-generation Elektronikon® operating system offers a wide variety of control and monitoring features that allow you to increase

your compressor’s efficiency and reliability. To maximize energy efficiency, the Elektronikon® controls the main drive motor and regulates

system pressure within a predefined and narrow pressure band.

Improved user-friendliness
3.5-inch high-definition color display with clear pictograms
 On-screen Delayed Second Stop function and VSD

and extra 4th LED indicator for service. savings indication.


Graphical display of key parameters (day, week, month) and
 Graphical indication Serviceplan, remote control and

32 language settings. connectivity functions.


Internet-based compressor visualization using a simple
 Software upgrade available to control up to 6 compressors

Ethernet connection. by installing the optional integrated compressor controller.

Online & mobile monitoring


Monitor your compressors over the Ethernet with the
new Elektronikon® controller. Monitoring features
include warning indications, compressor shut-down and
maintenance scheduling. The Atlas Copco App is
available for iPhone/Android phones as well as iPad
and Android tablets. It allows fingertip monitoring
of your compressed air system through your own
secured network.
Optional integrated compressor controller
Install, with a simple license, the optional integrated compressor controller and get simple, central control to reduce system pressure and

energy consumption in installations of up to 4 (ES4i) or 6 (ES6i) compressors.

Net Pressure WITHOUT CONTROL WITH CONTROL

1
2
Average Pressure
3 1 2 3 Average Pressure
Min. System Pressure Min. System Pressure

Compressors

The Elektronikon® continuously monitors critical parameters. Monitoring features include service and warning indications, error detection, compressor
shut-down and maintenance scheduling.

Dual pressure set point & Delayed Second stop


Most production processes create fluctuating levels of demand use times. In addition, the sophisticated Delayed Second Stop
which, in turn, can create energy waste in low use periods. (DSS) runs the drive motor only when needed. As the desired
Using either the standard or graphic Elektronikon® controller, system pressure is maintained while the drive motor’s run time
you can manually or automatically create two different system is minimized, energy consumption is kept at a minimum.
pressure bands to optimize energy use and reduce costs at low

Without DSS With DSS

Power Power

Loaded Loaded
Unloaded Unloaded
Stopped
Time Time

Saved energy

Integrated Dryer Saver Cycle


Saver Cycle technology reduces the energy consumption of the dew point suppression, the Elektronikon® starts and stops the
integrated refrigerant dryers with the fan in light load dryer and the fan, minimizing energy use and protecting the air
applications. Using an ambient sensor to monitor the required system from corrosion.
Excellence in integrated air quality
Untreated compressed air contains moisture, aerosols and dirt particles that can damage your air system and contaminate your end product,

resulting in risk of corrosion and compressed air system leaks. Maintenance costs can far exceed air treatment costs. Our compressors provide the

clean, dry air that improves your system’s reliability, avoids costly downtime and production delays, and safeguards the quality of your products.

Save money and the environment


Avoid risk of corrosion and system leaks, and ensure the
effective safe disposal of untreated condensate – all within ISO
14001 standards.

E
ZERO OZON
DEPLETION
On average 50% energy savings with
R410A integrated dryers
- Use of energy-efficient refrigerant R410A reduces operating costs.
- R410A refrigerant reduces global warming potential by an average
of 50%.
- Environmentally-friendly characteristics; zero ozone depletion.
- Unique Saver Cycle Control, with ambient temperature sensor and
based on dryer load and relative humidity of compressed air, saves
energy at partial load.
- Heat exchanger cross-flow technology with low pressure drop.
- Zero waste of compressed air thanks to no-loss condensate drain.
- Pressure dew point of 3°C (100% relative humidity at 20°C).

Integrated purity
The optional DD/PD filters and integrated refrigerant air dryer downstream equipment, increasing efficiency and ensuring
(IFD) efficiently remove moisture, aerosols and dirt particles to quality of your final product.
protect your investment. This air quality prolongs the life of

ISO quality class* Dirt particle size Water pressure dew point** Oil concentration

3.-.4 3 microns - 3 ppm

3.4.4 3 microns +3ºC, 37ºF 3 ppm

2.4.2 1 micron +3ºC, 37ºF 0.1 ppm

1.4.1 0.01 microns +3ºC, 37ºF 0.01 ppm

* The table values reflect the maximum limits according to the temperature ISO gravity class.
** Water pressure dew point based on 100% RH at 20°C/68°F.
WorkPlace: Compressed air at the point of use
With the industry-leading low noise operation and integration of air and condensate treatment equipment, the GA+ offers complete versatility

for your production. The compressor’s integrated design allows it to be placed on the production floor, creating substantial energy savings for

your business.

Low installation costs


The GA+ can operate close to the point of use – eliminating the need for a dedicated compressor room.

The GA+ is delivered ready for use – minimizing production downtime and reducing installation costs.

Filtration equipment is integrated – reducing the need for costly external piping and minimizing pressure drops.

Low noise enables the above to be a reality.


Reduced energy and maintenance costs


With less external piping, the GA+ minimizes pressure drop across the system which can reduce energy costs.

The filtration system produces clean air to prevent network corrosion – minimizing energy, repair and maintenance costs.

The GA+ operates at the lowest possible system pressure to reduce energy costs thanks to the Elektronikon® advanced

monitoring system.

Integrated condensate management


OSCi is an efficient integrated solution that removes oil from condensate.

Oil carryover contained in condensate can harm the environment.


Treated condensate protects water, wildlife and ecosystems.


The delivered water is harmless and can be disposed in a sewage system,


reducing disposal costs.


Optimize your system
Some applications may need or may benefit from additional options and more refined control/air treatment systems. To meet these needs,

Atlas Copco has developed options and easily integrated compatible equipment.

GA 30+-90 GA 37-90 VSD

Integrated filter kit class 1*


Integrated filter kit class 2*
Air treatment Dryer bypass*

Condensate OSCi

Motor space heater -


Motor space heater + thermistors -
Water shut-off valve**
Phase sequence relay (export) -
Tropical thermostat -
Freeze protection
Pre-filter
Advanced monitoring
Protection Electronic water drain (EWD)

Rain protection -
Public works Main power isolator switch

ES 100 relays***
AIRconnect
Elektronikon® Graphic upgrade (only for GA 37 to GA 75) -
ES4i/ES6i (for Elektronikon® Graphic)
Communication Digital I/O expansion module

Food grade oil


Oils Roto – Xtend duty oil (8000 hours)

Witness performance test


Energy recovery
Modulating control -
High-ambient temperature version (HAV 55°C, 131°F)****
General options IT/TT ancillaries -
*FF units only. ** Water-cooled units. *** Includes potential-free contacts: motor running, compressor load/unload. **** FF units max 50°C, 122°F.

Integrated Energy Recovery


As much as 90% of the electrical energy used by a compressed air solution is converted into heat. Using Atlas Copco’s integrated
energy recovery systems, it is feasible to recover up to 75% of that power input as hot air or hot water without any influence on the
compressor’s performance. Through efficient usage of the recovered energy, you bring about important energy cost savings and
obtain a high return on investment.

Energy recovery applications


Auxiliary or main heating of warehouses, workshops etc.

Industrial process heating.


Water heating for laundries, industrial cleaning and sanitary facilities.


Canteens and large kitchens.


Food industry.

Chemical and pharmaceutical industries.


Drying processes.

Flow charts
Variable Speed Drive: GA VSD

E
A Intake air
B Air/oil mixture
C Oil
A D Wet compressed air
E Condensate
F Dried compressed air
D
B
E

C
Vp

A Intake air D Wet compressed air


Fixed
B speed:
Air/oilGA +
& GA E
mixture Condensate
C Oil F Dried compressed air

E
A Intake air
B Air/oil mixture
C Oil
D Wet compressed air
E Condensate
F Dried compressed air
A D
B
E

C
Vp

A Intake air D Wet compressed air

B Air/oil mixture E Condensate

C Oil F Dried compressed air

GA 37, 45 VSD Width 1766 mm, 69.5"


H
GA 30+, 37+, 45+ Depth 970 mm, 38.2"
GA 37, 45 Height 1800 mm, 70.9"

GA 55, 75, 90 VSD Width 2248 mm, 88.5"


GA 55+, 75+ Depth 1080 mm, 42.5"
GA 55, 75, 90 Height 1955 mm, 76.9"

D
W
Technical specifications GA 30+-90 (50 Hz versions)
Weight
Max. working pressure Noise Weight
Capacity FAD* Installed motor power WorkPlace
Compressor Pressure WorkPlace level** WorkPlace Full Feature
TYPE variant
bar(e) psig l/s m3/min cfm kW hp dB(A) kg lbs kg lbs

GA 30 +
7.5 7.5 109 99 5.9 209 30 40 65 917 2022 998 2200
8.5 8.5 123 90 5.4 191 30 40 65 917 2022 998 2200
10 10.0 145 82 4.9 175 30 40 65 917 2022 998 2200
13 13.0 189 71 4.3 151 30 40 65 917 2022 998 2200
GA 37 7.5 7.5 109 115 6.9 243 37 50 69 920 2028 1005 2216
8.5 8.5 123 106 6.4 225 37 50 69 920 2028 1005 2216
10 10.0 145 100 6.0 213 37 50 69 920 2028 1005 2216
13 13.0 189 81 4.9 172 37 50 69 920 2028 1005 2216
GA 37+ 7.5 7.5 109 122 7.3 258 37 50 65 1002 2209 1087 2396
8.5 8.5 123 118 7.1 250 37 50 65 1002 2209 1087 2396
10 10.0 145 102 6.1 216 37 50 65 1002 2209 1087 2396
13 13.0 189 85 5.1 180 37 50 65 1002 2209 1087 2396
GA 45 7.5 7.5 109 137 8.2 291 45 60 72 994 2191 1079 2379
8.5 8.5 123 127 7.6 268 45 60 72 994 2191 1079 2379
10 10.0 145 117 7.0 248 45 60 72 994 2191 1079 2379
13 13.0 189 102 6.1 217 45 60 72 994 2191 1079 2379
GA 45+ 7.5 7.5 109 149 8.9 315 45 60 66 1070 2359 1160 2557
8.5 8.5 123 139 8.3 295 45 60 66 1070 2359 1160 2557
10 10.0 145 128 7.7 270 45 60 66 1070 2359 1160 2557
13 13.0 189 106 6.4 225 45 60 66 1070 2359 1160 2557
GA 55 7.5 7.5 109 169 10.1 359 55 75 69 1329 2930 1429 3150
8.5 8.5 123 159 9.5 337 55 75 69 1329 2930 1429 3150
10 10.0 145 148 8.9 313 55 75 69 1329 2930 1429 3150
13 13.0 189 126 7.6 267 55 75 69 1329 2930 1429 3150
GA 55 + 7.5 7.5 109 180 10.8 381 55 75 66 1458 3214 1558 3435
8.5 8.5 123 172 10.3 364 55 75 66 1458 3214 1558 3435
10 10.0 145 153 9.2 324 55 75 66 1458 3214 1558 3435
GA 75 7.5 7.5 109 226 13.6 478 75 100 66 1371 3023 1491 3287
8.5 8.5 123 209 12.5 444 75 100 73 1371 3023 1491 3287
10 10.0 145 190 11.4 401 75 100 73 1371 3023 1491 3287
13 13.0 189 162 9.7 344 75 100 73 1371 3023 1491 3287
GA 75+ 7.5 7.5 109 247 14.8 523 75 100 68 1525 3362 1645 3627
8.5 8.5 123 232 13.9 492 75 100 68 1525 3362 1645 3627
10 10.0 145 207 12.4 439 75 100 68 1525 3362 1645 3627
13 13.0 189 173 10.4 367 75 100 68 1525 3362 1645 3627
GA 90 7.5 7.5 109 281 16.9 596 90 125 73 1525 3362 1645 3627
8.5 8.5 123 275 16.5 582 90 125 73 1525 3362 1645 3627
10 10.0 145 250 15.0 529 90 125 73 1525 3362 1645 3627
13 13.0 189 216 13.0 458 90 125 73 1525 3362 1645 3627

* Unit performance measured according to ISO 1217, Annex C, Edition 4


Reference conditions:
 Absolute inlet pressure 1 bar (14.5 psi)

 Intake air temperature 20°C, 68°F

FAD is measured at the following working pressures:


 7.5 bar versions at 7 bar

 8.5 bar versions at 8 bar

 10 bar versions at 9.5 bar

 13 bar versions at 12.5 bar

** A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.
Pressure dew point of integrated refrigerant dryer at reference conditions: 2ºC to 3ºC, 36°F to 37°F.
Technical specifications GA 30+-90 (60 Hz versions)
Weight
Max. working pressure Noise Weight
Capacity FAD* Installed motor power WorkPlace
Compressor Pressure WorkPlace level** WorkPlace Full Feature
TYPE variant
bar(e) psig l/s m3/min cfm kW hp dB(A) kg lbs kg lbs

GA 30 +
100 7.4 107 100 6.0 212 30 40 65 917 2022 998 2200
125 9.1 132 91 5.5 192 30 40 65 917 2022 998 2200
150 10.8 157 82 4.9 174 30 40 65 917 2022 998 2200
175 12.5 181 75 4.5 158 30 40 65 917 2022 998 2200
GA 37 100 7.4 107 116 7.0 246 37 50 69 920 2028 1005 2216
125 9.1 132 108 6.5 229 37 50 69 920 2028 1005 2216
150 10.8 157 96 5.8 204 37 50 69 920 2028 1005 2216
175 12.5 181 87 5.2 185 37 50 69 920 2028 1005 2216
GA 37+ 100 7.4 107 120 7.2 255 37 50 65 1002 2209 1087 2396
125 9.1 132 111 6.7 234 37 50 65 1002 2209 1087 2396
150 10.8 157 100 6.0 212 37 50 65 1002 2209 1087 2396
175 12.5 181 91 5.4 192 37 50 65 1002 2209 1087 2396
GA 45 100 7.4 107 139 8.3 294 45 60 72 994 2191 1079 2379
125 9.1 132 128 7.7 271 45 60 72 994 2191 1079 2379
150 10.8 157 118 7.1 250 45 60 72 994 2191 1079 2379
175 12.5 181 105 6.3 222 45 60 72 994 2191 1079 2379
GA 45+ 100 7.4 107 146 8.8 310 45 60 66 1070 2359 1160 2557
125 9.1 132 134 8.0 284 45 60 66 1070 2359 1160 2557
150 10.8 157 126 7.5 266 45 60 66 1070 2359 1160 2557
175 12.5 181 111 6.7 236 45 60 66 1070 2359 1160 2557
GA 55 100 7.4 107 174 10.5 369 55 75 69 1329 2930 1429 3150
125 9.1 132 154 9.3 327 55 75 69 1329 2930 1429 3150
150 10.8 157 142 8.5 300 55 75 69 1329 2930 1429 3150
175 12.5 181 128 7.7 272 55 75 69 1329 2930 1429 3150
GA 55 + 100 7.4 107 181 10.9 384 55 75 67 1458 3214 1558 3435
125 9.1 132 163 9.8 345 55 75 67 1458 3214 1558 3435
150 10.8 157 138 8.3 292 55 75 67 1458 3214 1558 3435
GA 75 100 7.4 107 225 13.5 476 75 100 67 1371 3023 1491 3287
125 9.1 132 198 11.9 424 75 100 73 1371 3023 1491 3287
150 10.8 157 186 11.2 401 75 100 73 1371 3023 1491 3287
175 12.5 181 169 10.1 358 75 100 73 1371 3023 1491 3287
GA 75 + 100 7.4 107 247 14.8 523 75 100 69 1525 3362 1645 3627
125 9.1 132 226 13.6 479 75 100 69 1525 3362 1645 3627
150 10.8 157 201 12.1 426 75 100 69 1525 3362 1645 3627
175 12.5 181 179 10.7 379 75 100 69 1525 3362 1645 3627
GA 90 100 7.4 107 284 17.0 602 90 125 74 1525 3362 1645 3627
125 9.1 132 262 15.7 555 90 125 74 1525 3362 1645 3627
150 10.8 157 245 14.7 519 90 125 74 1525 3362 1645 3627
175 12.5 181 224 13.4 475 90 125 74 1525 3362 1645 3627
Please refer to the footnotes, reference conditions and FAD details of the 50 Hz versions.

Technical specifications GA 37-90 VSD (50/60 Hz versions)

Capacity FAD* Weight


Installed motor Noise Weight
Working pressure WorkPlace
Compressor power level** WorkPlace
Full Feature
TYPE l/s m /min
3
cfm

bar(e) psig min max min max min max kW hp dB(A) kg lbs kg lbs

GA 37 VSD 4 58 26.0 124 1.6 7.4 55 263 37 50 66/67 1142 2518 1227 2705
7 102 26.0 123 1.6 7.4 55 260 37 50 66/67 1142 2518 1227 2705
10 145 25.8 107 1.5 6.4 55 226 37 50 66/67 1142 2518 1227 2705
13 189 40.3 87 2.4 5.2 85 185 37 50 66/67 1142 2518 1227 2705
GA 45 VSD 4 58 26.0 146 1.6 8.8 55 310 45 60 69/72 1200 2646 1290 2844
7 102 26.0 145 1.6 8.7 55 307 45 60 69/72 1200 2646 1290 2844
10 145 25.8 128 1.5 7.7 55 271 45 60 69/72 1200 2646 1290 2844
13 189 40.3 107 2.4 6.4 85 226 45 60 69/72 1200 2646 1290 2844
GA 55 VSD 4 58 32.4 197 1.9 11.8 69 418 55 75 69/72 1480 3263 1580 3483
7 102 26.0 175 1.6 10.5 55 371 55 75 69/72 1480 3263 1580 3483
10 145 25.4 155 1.5 9.3 54 328 55 75 69/72 1480 3263 1580 3483
13 189 37.0 129 2.2 7.7 78 273 55 75 69/72 1480 3263 1580 3483
GA 75 VSD 4 58 37.8 248 2.3 14.9 80 525 75 100 69/70 1632 3598 1752 3862
7 102 37.4 246 2.2 14.8 79 521 75 100 69/70 1632 3598 1752 3862
10 145 48.1 216 2.9 13.0 102 458 75 100 69/70 1632 3598 1752 3862
13 189 58.3 180 3.5 10.8 124 381 75 100 69/70 1632 3598 1752 3862
GA 90 VSD 4 58 37.0 290 2.2 17.4 78 614 90 125 73/74 1632 3598 1752 3862
7 102 39.4 289 2.4 17.3 84 612 90 125 73/74 1632 3598 1752 3862
10 145 48.3 253 2.9 15.2 102 536 90 125 73/74 1632 3598 1752 3862
13 189 59.4 209 3.6 12.5 126 443 90 125 73/74 1632 3598 1752 3862
* Unit performance measured according to ISO 1217, Annex E, Edition 4
Maximum working pressure for VSD machines: 13 bar(e) (188 psig)
Driven by innovation
With more than 135 years of innovation and experience, Atlas Copco will deliver the
products and services to help maximize your company’s efficiency and productivity.
As an industry leader, we are dedicated to offering high air quality at the lowest
possible cost of ownership. Through continuous innovation, we strive to safeguard
your bottom line and bring you peace of mind.

2935 0814 40 – Printed in Belgium – Subject to alteration without prior notice. Never use compressed air as breathing air without prior purification in accordance with local legislation and standards.
Building on interaction
As part of our long-term relationship with our customers, we have accumulated
extensive knowledge of a wide diversity of processes, needs and objectives. This
gives us the flexibility to adapt and efficiently produce customized compressed air
solutions that meet and exceed your expectations.

A committed business partner


With a presence in over 170 countries, we will deliver high-quality customer
service anywhere, anytime. Our highly skilled technicians are available 24/7
and are supported by an efficient logistics organization, ensuring fast delivery
of genuine spare parts when you need them. We are committed to providing
the best possible know-how and technology to help your company produce,
grow, and succeed. With Atlas Copco you can rest assured that your superior
productivity is our first concern!

www.atlascopco.com
OIL-INJECTED
ROTARY SCREW
COMPRESSORS

GA 90+-160/GA 110-160 VSD (90-160 kW/125-200 hp)


OUTSTANDING PERFORMANCE,
MAXIMUM BENEFITS
GA 90+-160 and GA 110-160 VSD compressors provide high-quality compressed air in the harshest
environmental conditions. Incorporating the patented Atlas Copco’s oil-injected screw element, they provide
a long and trouble-free life at the lowest possible operating cost.

Metal industry
Metal plants use compressed air for instrumentation, plant air
and pneumatic conveying for raw materials or ash and are in
need of an efficient solution to reduce their operating costs.
Thanks to their innovative features, our GA air compressors
meet this demand.

Mining industry
Compressed air is vital for the mining industry: applications
include dust bag filtration, service air, ventilation air and
pneumatic tools. The reliability and robustness of
GA air compressors will accomplish the job even
in the harshest conditions.

Power plants
Power plants run round-the-clock to supply vital energy.
A continuous supply of compressed air is absolutely critical
for trouble-free operation. GA compressors provide a reliable
source of compressed air for applications such as silt blowing
and fly ash handling.

General industry
Many industrial companies use compressed air in their daily
operations. Applications include pneumatic tools for cutting,
drilling, hammering and grinding; pneumatic actuators and
valves; ventilation systems; packing and palleting machinery
and conveyor systems. GA compressors are designed for
ultimate performance and reliability.
Keeping your production
up and running
GA compressors ensure long and trouble-free lifetime at the
lowest operating cost. At their heart are state-of-the-art
compression elements based on innovative asymmetric rotor
profiles and powered by a high efficiency electric motor.
Combined with a built-to-last drive system and heavy duty air
inlet filters, this results in maximum reliability to operate in
the toughest conditions and at ambient temperatures up
to 55°C/131°F.

Reducing your production costs


The innovative design of GA compressors reduces your energy
bill and overall compressor lifecycle costs. GA compressors
are pre-assembled packages: installation is fault-free,
commissioning time is low and no external instrumentation
air is required.

Protecting your process


The Full Feature concept includes compressed air and air
treatment equipment integrated in the compressor canopy.
This limits installation costs and space requirements.
The integrated water separator immediately removes 100%
of the condensate, resulting in higher air quality.

Maximizing your savings


As there is no “one size fits all” concept, we have developed
a range of features and options to help you optimize the use
of your compressor: from running the machine at high
temperatures, to extra safety devices.
SETTING A NEW STANDARD
IN THE INDUSTRY
GA compressors bring you outstanding sustainability, reliability and performance, while minimizing the
total cost of ownership. Built to perform even in the harshest environments, these compressors keep your
production running efficiently.

1
Superior air quality
• Standard integrated water
separator to remove 100%
of the condensate with
electronic drain.
• 3-step efficient oil separation
process for low residual oil
content in the compressed air
(less than 3 ppm).
9

10
2
State-of-the-art screw element
• Patented asymmetric rotor profile for maximum efficiency. 1
• Bearing selection leads to low wear for
increased reliability.
11
3 5
Service friendly 2
• Selection of long lifetime consumables. 4
• Easy and safe access to all service parts. 3

4
Triple benefits with the gear driven transmission
• Built to last, totally enclosed and protected against dirt and dust.
• High-efficiency drive arrangement; no coupling or slippage losses.
• Coupling to absorb the thrust load and increase the reliability.

5
High efficient motor
• TEFC IP55 motor (Class F insulation B rise) protects against
dust and chemicals.
• Continuous operation under severe ambient temperature conditions.
6
Easy to install
• All inclusive package with flexible ducting possibilities.
• All user connections located on the same side of the compressor.
• Phase sequence relay as standard to protect the compressor against
reverse rotation.

7
Integrated refrigerant dryer
7 • Highly efficient dryer to increase the savings.

8 • Reduced floor space requirements.


• Optimized operation with the Elektronikon® unit controller.

8
Heavy duty air intake filter
• Protects the compressor components by removing 99.9% of dirt particles
down to 3 microns.
• Reduces the dust load in the fine filter, doubling the filter element lifetime
without reducing filter efficiency.

6
9
Cooling module
• Separated oil and after coolers for highest efficiency.
• Standard design up to 46°C/115°F and HAT (55°C/131°F) variant available.
• Cooling fans located in the middle for fresh air in the system to prevent
build-up of heat.
• Fans with low noise level.

11
Optimized loading/
unloading valve
10
• Assures constant optimized pressure in the
system resulting in high energy savings. Durable design
• Smart design with few moving parts for • Solid metal pipe for durable operation and reduced service costs.
highest reliability. • Rigid straight connections eliminate risk of leaks and improve
• Accurate control through solenoid valve. package efficiency.
VSD: DRIVING DOWN YOUR ENERGY COSTS
Over 70% of a compressor’s lifecycle cost is taken up by the energy it consumes. Moreover, the generation
of compressed air can account for more than 40% of a plant’s total electricity bill. To cut your energy costs,
Atlas Copco has pioneered Variable Speed Drive (VSD) technology for several decades. VSD leads to major
energy savings, reducing the consumption of energy producing fuels and protecting the environment
for future generations. Thanks to continual investments in this technology, we offer the widest range of
integrated VSD compressors on the market.

What is VSD technology?


In almost every production environment, air demand fluctuates depending on different factors (time of the day, week or even month).
Extensive measurements and studies of compressed air demand profiles show that many compressors have substantial variations
in air demand. Only 8% of all installations have a more stable air demand. Tests prove that, even in this case, VSD compressors
save energy.

Profile 1 Profile 2 Profile 3


MAX

MAX

MAX
• 64% of all installations. • 28% of all installations. • 8% of all installations.
• Factory working 24 hrs/day: low • Factory working 2 shifts/day, • Factory working 2 shifts/day,
demand at night & high demand no weekend work: erratically no weekend work: typical 'fixed'
during the day. varying air demand. speed application.

12%
Energy savings of up to 35%
Atlas Copco’s VSD technology closely follows the air
11% demand by automatically adjusting the motor speed.
35%
This results in large energy savings of up to 35%.
The Life Cycle Cost of a compressor can be cut by an
average of 22%. In addition, lowered system pressure
with VSD minimizes energy use across your
production dramatically.

Total compressor lifecycle cost


Energy Investment
42% Energy savings with VSD Maintenance
WHAT IS UNIQUE ABOUT THE INTEGRATED
ATLAS COPCO GA VSD?

Efficiency
External VSD operating range

Atlas Copco VSD operating range

Min. Max. Flow Flow

Integrated VSD Non-integrated VSD Flow gaps due to vibration and noise issues

1 The Elektronikon® unit controller manages both the 7 A highly efficient frequency converter in a cool
compressor and the integrated converter, ensuring overpressure cubicle ensures stable operation in high
maximum machine safety within parameters. ambient temperatures up to 50°C/122°F (standard up to
2 Flexible pressure selection from 4 to 13 bar with electronic 46°C/114.8°F).
gearing reduces electricity costs. 8 It is important to ensure that when using a Variable Speed
3 Specific converter and motor design (with protected Drive vibration and noise issues do not occur. Atlas Copco
bearings) for the highest efficiency across the speed range. compressors are designed and tested to guarantee they
operate across the entire frequency range of operation.
4 Electric motor specifically designed for low operating
When an external VSD drive is used it may become
speeds with clear attention to motor cooling and
necessary to limit the operating range of the compressor,
compressor cooling requirements.
leading to reduced energy saving and jeopardizing stable
5 All Atlas Copco GA VSD compressors are EMC tested and air network pressure.
certified. Compressor operation does not influence external
9 The cubicle cooling booster increases the lifetime
sources and vice versa.
of electrical components due to a cool cubicle in
6 Mechanical enhancements ensure that all components overpressure and reduced dust ingress.
operate below critical vibration levels throughout the entire
10 Net pressure band is maintained within 0.10 bar, 1.5 psi.
compressor speed range.

No current peaks
% Full load current

Star Delta
DOL
Soft Starter
VSD

Seconds
INCREASE YOUR SAVINGS WITH
ENERGY RECOVERY
The Kyoto directives and the continuing depletion of traditional energy sources mean that businesses
throughout the world are making commitments to significantly reduce overall energy consumption.
Through innovative products and solutions, Atlas Copco helps you achieve your goals in this area.
When it comes to compressed air production – where energy costs can constitute 70% of total lifecycle
costs – saving energy can also lead to substantial cost savings.

Integrated heat exchanger


Air compression creates heat that is normally wasted in the coolers. Energy recovery systems designed by Atlas Copco enable the
recovery of most of this heat. Recovery of energy from the shaft input of the compressor can be up to 94% of the compressor shaft
power. The heat is directly usable as a source of energy in the form of hot water (85-90°C/185- 194°F). The main module of the recovery
system is built into the compressor. The investment needed to link the hot oil circuit from the compressor to the existing water circuit
is relatively modest and the time needed before seeing payback from your investment is generally very short.

Shower Space heating Steam boiler Process Heat driven chillers Heat exchangers

Warm air heat recovery


The ducting on your GA compressors also constitutes a simple and smart solution to generate space heating. Ducting simply directs
the warmed cooling air to where it is needed – such as workshops, storage warehouses or other facilities. To cope with seasonal
changes, louver flaps can be used to vent the warm air to the outside. An installation with motorized and thermostatically controlled
louvers is the ideal solution to accurately monitor the temperature with a full control of the flow of heating air.

Applications:
• Heating of facilities, warehouses or workshops.
• Drying air for painting and washing applications.
PROTECT YOUR PRODUCTION WITH THE GA FF
Untreated compressed air contains moisture, aerosols and dirt particles that can damage your air system
and contaminate your end product, resulting in risk of corrosion and compressed air system leaks.
Maintenance costs can far exceed air treatment costs. Our compressors provide the clean, dry air that
improves your system’s reliability, avoids costly downtime and production delays, and safeguards the
quality of your products.

All-in-one quality air production


The GA FF (Full Feature) is a ready-to-use, compact package that guarantees a pressure dewpoint of 3°C/37°F (100% relative humidity
at 20°C/68°F). All the wires and pipes are assembled in the factory, so there is no need for additional installation work. The dryers can
perform at ambient conditions up to 46°C/115°F.

Save money and the environment Optimized air purity


The unique and patented Saver Cycle Control stops the The optional external filters and integrated refrigerant air dryer
dryer when the compressor is stopped or in unload mode, efficiently remove moisture, aerosols and dirt particles to protect
drastically reducing power consumption. The dewpoint is your investment. This air quality prolongs the life of downstream
continuously monitored and the dryer is re-started when the equipment, increasing efficiency, reducing maintenance
dewpoint begins to increase. requirements and ensuring quality of your final product.

Configure your GA
ISO Quality Class Dirt Particle Size Water Pressure Dew Point Oil Concentration
for the air quality you need

GA 3.-.4 3 microns - 3 ppm

GA FF with ID 3.4.4 3 microns +3°C, 37°F 3 ppm

GA FF with ID & general purpose


2.4.2 1 micron +3°C, 37°F 0.1 ppm
coalescing filter
MONITORING AND CONTROL: HOW TO GET
THE MOST FROM THE LEAST
The Elektronikon® unit controller is specially designed to maximize the performance of your compressors
and air treatment equipment under a variety of conditions. Our solutions provide you with key benefits
such as increased energy efficiency, lower energy consumption, reduced maintenance times and less
stress… less stress for both you and your entire air system.

Intelligence is part of the package


• High resolution color display gives you an easy to understand • Operation of the equipment to deliver specifically
readout of the equipment’s running conditions. and reliably to your compressed air needs.
• Clear icons and intuitive navigation provides you fast access • Built in remote control and notifications functions
to all of the important settings and data. provided as standard, including simple to use Ethernet
• Monitoring of the equipment running conditions and based communication.
maintenance status; bringing this information to your • Support for 31 different languages, including character
attention when needed. based languages.

Online & mobile monitoring


Monitor your compressors over the Ethernet with the
Elektronikon® unit controller. Monitoring features include
warning indications, compressor shut-down and
maintenance scheduling. An Atlas Copco App is available
for iPhone/Android phones as well as iPad and Android
tablets. It allows fingertip monitoring of your compressed
air system through your own secured network.
Full optimization -
ES system controller
Improve product quality every minute
that your facility is in operation.
Atlas Copco's ES system controllers
offer a convenient way to achieve
optimized performance from your low
pressure equipment through a single
centralized point of monitoring and
control. With the ES system controller
watching over your compressors and
compressed air network, you will have
a highly dependable and energy
efficient solution working with your
facility to manage operating costs.
Stores Measures

Protects

Controls

Communicates

Dual pressure set-point and Delayed Second Stop


Most production processes create fluctuating levels of demand which, in turn, can create energy waste in low use periods. Using the
graphic Elektronikon® unit controller, you can manually or automatically create two different system pressure bands to optimize energy
use and reduce costs at low use times. In addition, the sophisticated Delayed Second Stop (DSS) runs the drive motor only when
needed. As the desired system pressure is maintained while the drive motor’s run time is minimized, energy consumption is kept
to a minimum.

Without DSS With DSS


Power Power

Loaded
Loaded Unloaded

Unloaded Stopped

Time Time
Saved energy

SMARTLINK*: Data Monitoring Program


• A remote monitoring system that helps you optimize your
compressed air system and save you energy and cost.
• It offers you a complete insight in your compressed air
network and anticipates on potential problems by warning
you up-front.
*Please contact your local sales representative for more information.
OPTIMIZE YOUR SYSTEM
Efficient air inlet filters and flexibles
Air intake valve
Air circuit Full load/no load regulation system

Heavy-duty oil filters


Complete oil circuit
Oil circuit Air/oil separation system

Compressed air aftercooler and oil cooler


Stainless steel tube and Shell coolers for water-cooled versions
Axial cooling fans for air-cooled versions.
Integrated water separator
Electronic water drains with no loss of compressed air
Complete air, oil, water circuit
Cooling circuit Roto Xtend duty synthetic lubricant

TEFC IP55 Class F electric motor


Starters (Star-Delta)
Elektronikon® unit controller
Electrical components Phase sequence relay

Flexible vibration dampers


Silenced canopy
Structural skid with no need for foundations
Framework Suppression of emissions/harmonic distortions

ADDITIONAL FEATURES & OPTIONS


GA 90+-160 GA 110-160 VSD

Full Feature: integrated ID refrigerant dryer • •

High ambient version (up to 55°C/131°F)* • •

Integrated Energy Recovery system • •

Modulation control • -

Full option motor (PT1000 thermal protection and Anti-condensation heaters) • -

SPM vibration monitoring system • •

Anchor pads • •

NPT or ANSI connections • •

Performance test certificate • •

Witnessed performance test • •

Material certificates • •

Seaworthy packaging • •

* GA VSD up to 50°C/122°F; GA fix speed Pack up to 55°C/131°F. Not available on Full Feature. • : Optional - : Not available
FLOW CHART
Fixed speed: GA+ & GA

A D
B
E
A Intake air

B Air/oil mixture

C C Oil
Vp
D Wet compressed air

E Condensate

F Dried compressed air

A Intake air D Wet compressed air

B Air/oil mixture E Condensate

C Oil F Dried compressed air

Variable Speed Drive: GA VSD

D
B
E
A Intake air

B Air/oil mixture

C Oil
C
Vp D Wet compressed air

E Condensate

F Dried compressed air

A Intake air D Wet compressed air

B Air/oil mixture E Condensate


C Oil F Dried compressed air
TECHNICAL SPECIFICATIONS 50 Hz
Working pressure Weight
Installed motor Noise
Capacity FAD1
TYPE power level2
Standard Full Feature 3
Standard Full Feature

bar(e) psig bar(e) psig l/s m3/min cfm kW hp dB(A) kg lbs kg lbs
GA 90+ 5.5 80 5.3 77 336 20.2 712 90 125 74 3000 6614 3393 7480
7.5 109 7.3 106 293 17.6 621 90 125 74 3000 6614 3393 7480
8.5 123 8.3 120 280 16,8 593 90 125 74 3000 6614 3393 7480
10 145 9.8 142 253 15.2 536 90 125 74 3000 6614 3393 7480
GA 110 5.5 80 5.3 77 402 24.1 852 110 150 74 3100 6834 3493 7701
7.5 109 7.3 106 364 21.8 771 110 150 74 3100 6834 3493 7701
8.5 123 8.3 120 340 20.4 720 110 150 74 3100 6834 3493 7701
10 145 9.8 142 312 18.7 661 110 150 74 3100 6834 3493 7701
14 203 13.8 200 239 14.3 506 110 150 74 3100 6834 3493 7701
GA 132 5.5 80 5.3 77 474 28.4 1004 132 175 74 3375 7441 3768 8307
7.5 109 7.3 106 430 25.8 911 132 175 74 3375 7441 3768 8307
8.5 123 8.3 120 401 24.1 850 132 175 74 3375 7441 3768 8307
10 145 9.8 142 373 22.4 790 132 175 74 3375 7441 3768 8307
14 203 13.8 200 300 18.0 636 132 175 74 3375 7441 3768 8307
GA 160 7.5 109 7.3 106 508 30.5 1076 160 215 74 3440 7584 3833 8451
8.5 123 8.3 120 485 29.1 1028 160 215 74 3440 7584 3833 8451
10 145 9.8 142 452 27.1 958 160 215 74 3440 7584 3833 8451
14 203 13.8 200 361 21.7 765 160 215 74 3440 7584 3833 8451

Working pressure Capacity FAD1 Installed Weight


Noise
motor
Type level2
Standard Full Feature 3
Standard / Full Feature power Standard Full Feature
50 Hz

bar(e) psig bar(e) psig l/s m /min


3
cfm kW dB(A) kg lbs kg lbs

Minimum 5 72 5 72 128 - 437 7.7 - 26.2 271 - 926


GA 110 VSD -
Nominal 7 101 7 101 128 - 392 7.7 - 23.5 271 - 831 110 78 3375 7441 4015 8851
8.5 bar
Maximum 8.5 123 8.3 120 154 - 359 9.2 - 21.5 326 - 761
Minimum 6 87 6 87 182 - 411 10.9 - 24.7 386 - 871
GA 110 VSD -
Nominal 9.5 138 9.5 138 177 - 334 10.6 - 20.0 375. 708 110 78 3375 7441 3975 8763
10 bar
Maximum 10 145 9.8 142 176 - 325 10.6 - 19.5 373 - 689
Minimum 9 131 9 131 178 - 344 10.7 - 20.6 377 - 729
GA 110 VSD -
Nominal 13.5 196 12.5 181 166 - 266 10.0 - 16.0 352 - 564 110 78 3375 7441 3950 8708
14 bar
Maximum 14 203 12.8 185 165 - 258 9.9 - 15.5 350 - 547
Minimum 5 72 5 72 128 - 513 7.7 - 30.8 271 - 1087
GA 132 VSD -
Nominal 7 101 7 101 128 - 463 7.7 - 27.8 271 - 981 132 78 3415 7529 4050 8929
8.5 bar
Maximum 8.5 123 8.3 120 154 - 426 9.2 - 25.6 326 - 903
Minimum 6 87 6 87 182 - 484 10.9 - 29.0 386 - 1026
GA 132 VSD -
Nominal 9.5 138 9.5 138 177 - 399 10.6 - 23.9 375 - 845 132 78 3415 7529 4050 8929
10 bar
Maximum 10 145 9.8 142 176 - 389 10.6 - 23.3 373 - 824
Minimum 9 131 9 131 178 - 409 10.7 - 24.5 377 - 867
GA 132 VSD -
Nominal 13.5 196 12.5 181 166 - 324 10.0 - 19.4 352 - 687 132 78 3415 7529 4050 8929
14 bar
Maximum 14 203 12.8 185 165 - 316 9.9 - 19.0 350 - 670
Minimum 5 72 5 72 128 - 569 7.7 - 34.1 271 - 1206
GA 160 VSD -
Nominal 7 101 7 101 128 - 548 7.7 - 32.9 271 - 1161 160 78 3515 7749 4155 9160
8.5 bar
Maximum 8.5 123 8.3 120 154 - 507 9.2 - 30.4 326 - 1074
Minimum 6 87 6 87 182 - 565 10.9 - 33.9 385 - 1197
GA 160 VSD -
Nominal 9.5 138 9.5 138 177 - 477 10.6 - 28.6 375 - 1011 160 78 3515 7749 4155 9160
10 bar
Maximum 10 145 9.8 142 176 - 466 10.6 - 28.0 373 - 987
Minimum 9 131 9 131 178 - 489 10.7 - 29.3 377 - 1036
GA 160 VSD -
Nominal 13.5 196 12.5 181 166 - 395 10.0 - 23.7 352 - 837 160 78 3515 7749 4155 9160
14 bar
Maximum 14 203 12.8 185 165 - 385 9.9 - 23.1 350 - 816

(1) Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009). (3) Integrated dryer: compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).
Reference conditions:
• Absolute inlet pressure 1 bar (14.5 psi). FAD(1) is measured at the following working pressures:
• Intake air temperature 20°C (68°F). 8.5 bar version at 7 bar (Standard & FF)
(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with 10 bar version at 9.5 bar (Standard & FF)
uncertainty 3 dB). Values determined according to noise level test code ISO 2151 and noise 14 bar version at 13.5 bar (Standard) / 12.5 bar (FF)
measurement standard ISO 9614.
Pressure dew point of integrated refrigerant dryer at reference conditions: 2°C to 3°C (36°F to 37°F).

DIMENSIONS
Standard Full Feature
Type L W H L W H L W H L W H
mm inch mm inch
GA 90+/GA 110-160 air-cooled & water-cooled 2800 2000 2000 111 79 79 3700 2000 2000 146 79 79
GA 110-160 VSD air-cooled 3200 2000 2347 126 79 92 3800 2002 2347 150 79 92
GA 110-160 VSD water-cooled 3200 1630 2347 126 64 92 3200 1630 2347 126 64 92
TECHNICAL SPECIFICATIONS 60 Hz
Working pressure Weight
Installed motor Noise
Capacity FAD1
TYPE power level2
Standard Full Feature 3
Standard Full Feature

bar(e) psig bar(e) psig l/s m3/min cfm kW hp dB(A) kg lbs kg lbs
GA 90+ 5.5 80 5.3 77 343 20.5 727 90 125 74 3000 6614 3393 7480
7.4 107 7.2 104 302 18.1 640 90 125 74 3000 6614 3393 7480
9.1 132 8.9 129 274 16.4 581 90 125 74 3000 6614 3393 7480
10.9 158 10.7 155 239 14.3 506 90 125 74 3000 6614 3393 7480
GA 110 5.5 80 5.3 77 406 24.3 860 110 150 74 3100 6834 3493 7701
7.4 107 7.2 104 363 21.7 769 110 150 74 3100 6834 3493 7701
9.1 132 8.9 129 331 19.8 701 110 150 74 3100 6834 3493 7701
10.9 158 10.7 155 295 17.7 625 110 150 74 3100 6834 3493 7701
14 203 13.5 196 248 14.9 525 110 150 74 3100 6834 3493 7701
GA 132 5.5 80 5.3 77 467 28.0 990 132 175 74 3375 7441 3768 8307
7.4 107 7.2 104 421 25.2 892 132 175 74 3375 7441 3768 8307
9.1 132 8.9 129 385 23.1 816 132 175 74 3375 7441 3768 8307
10.9 158 10.7 155 346 20.7 733 132 175 74 3375 7441 3768 8307
14 203 13.5 196 290 17.4 614 132 175 74 3375 7441 3768 8307
GA 160 7.4 107 7.2 104 475 28.4 1006 160 215 74 3440 7584 3833 8451
9.1 132 8.9 129 437 26.2 926 160 215 74 3440 7584 3833 8451
10.9 158 10.7 155 397 23.8 841 160 215 74 3440 7584 3833 8451
14 203 13.5 196 337 20.2 714 160 215 74 3440 7584 3833 8451

Working pressure Capacity FAD1 Installed Weight


Noise
motor
Type level2
Standard Full Feature 3
Standard / Full Feature power Standard / Full Feature
60 Hz

bar(e) psig bar(e) psig l/s m /min


3
cfm kW dB(A) kg lbs kg lbs

Minimum 5 72 5 72 128 - 437 7.7 - 26.2 271 - 926


GA 110 VSD -
8.6 bar Nominal 6.9 100 6.9 100 128 - 394 7.7 - 23.6 271 - 835 110 78 3375 7441 4015 8851
(125 psi) Maximum 9.1 132 8.9 129 154 - 349 9.2 - 20.9 326 - 739
Minimum 6 87 6 87 182 - 411 10.9 - 24.7 386 - 871
GA 110 VSD -
10,4 bar Nominal 10.4 151 10.4 151 175 - 317 10.5 - 19.0 371 - 672 110 78 3375 7441 3975 8763
(150 psi) Maximum 10.9 158 10.7 155 174 - 308 10.4 - 18.5 369 - 653
Minimum 9 131 9 131 178 - 344 10.7 - 20.6 377 - 729
GA 110 VSD -
13,8 bar Nominal 13.5 196 12.5 181 166 - 266 10.0 - 16.0 352 - 564 110 78 3375 7441 3950 8708
(200 psi) Maximum 14 203 12.8 185 165 - 258 9.9. - 15.5 350 - 547
Minimum 5 72 5 72 128 - 513 7.7 - 30.8 271 - 1087
GA 132 VSD -
8,6 bar Nominal 6.9 100 6.9 100 128 - 465 7.7 - 27.9 271 - 985 132 78 3415 7529 4050 8929
(125 psi) Maximum 9.1 132 8.9 129 154 - 414 9.2 - 24.8 326 - 877
Minimum 6 87 6 87 182 - 484 10.9 - 29.0 386 - 1026
GA 132 VSD -
10,4 bar Nominal 10.4 151 10.4 151 175 - 380 10.5 - 22.8 371 - 805 132 78 3415 7529 4050 8929
(150 psi) Maximum 10.9 158 10.7 155 174 - 370 10.4 - 22.2 369 - 784
Minimum 9 131 9 131 178 - 409 10.7 - 24.5 377 - 867
GA 132 VSD -
13,8 bar Nominal 13.5 196 12.5 181 166 - 324 10.0 - 19.4 352 - 687 132 78 3415 7529 4050 8929
(200 psi) Maximum 14 203 12.8 185 165 - 316 9.9 - 19.0 350 - 670
Minimum 5 72 5 72 128 - 569 7.7 - 34.1 271 - 1206
GA 160 VSD -
8,6 bar Nominal 6.9 100 6.9 100 128 - 551 7.7 - 33.1 271 - 1168 160 78 3515 7749 4155 9160
(125 psi) Maximum 9.1 132 8.9 129 154 - 494 9.2 - 29.6 326 - 1047
Minimum 6 87 6 87 182 - 565 10.9 - 33.9 386 - 1197
GA 160 VSD -
10,4 bar Nominal 10.4 151 10.4 151 175 - 456 10.5 - 27.4 371 - 966 160 78 3515 7749 4155 9160
(150 psi) Maximum 10.9 158 10.7 155 174 - 444 10.4 - 26.6 369 - 941
Minimum 9 131 9 131 178 - 489 10.7 - 29.3 377 - 1036
GA 160 VSD - 1
3,8 bar Nominal 13.5 196 12.5 181 166 - 395 10.0 - 23.7 352 - 837 160 78 3515 7749 4155 9160
(200 psi) Maximum 14 203 12.8 185 165 - 385 9.9 - 23.1 350 - 816

(1) Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009). (3) Integrated dryer: compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).
Reference conditions:
• Absolute inlet pressure 1 bar (14.5 psi). FAD(1) is measured at the following working pressures:
• Intake air temperature 20°C (68°F). 125 psi version at 100 psi (Standard & FF)
(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with 150 psi version at 150 psi (Standard & FF)
uncertainty 3 dB). Values determined according to noise level test code ISO 2151 and noise 200 psi version at 196 psi (Standard) / 181 psi (FF)
measurement standard ISO 9614.
Pressure dew point of integrated refrigerant dryer at reference conditions: 2°C to 3°C (36°F to 37°F).

DIMENSIONS
Standard Full Feature
TYPE L W H L W H L W H L W H
mm inch mm inch
GA 90+/GA 110-160 air-cooled & water-cooled 2800 2000 2000 111 79 79 3700 2000 2000 146 79 79
GA 110-160 VSD air-cooled 3200 2000 2347 126 79 92 3800 2002 2347 150 79 92
GA 110-160 VSD water-cooled 3200 1630 2347 126 64 92 3200 1630 2347 126 64 92
2935 0678 03 © 2016, Atlas Copco, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the
environment and the people around us. We make performance stand
the test of time. This is what we call – Sustainable Productivity.

www.atlascopco.com
Oil-injected rotary
screw compressors

GA 355-500 (355-500 kW / 450-700 hp)


Outstanding performance
GA 355-500 compressors provide high-quality compressed air in the harshest environmental conditions.
Incorporating the patented Atlas Copco’s oil-injected screw element, they provide a long and trouble-free
life at the lowest possible operating cost.

Metal industry
QUALITY AND EFFICIENCY
Metal plants use compressed air for instrumentation, plant air and
pneumatic conveying for raw materials or ash and are in need of
an efficient solution to reduce their operating costs. Thanks to their
innovative features, our GA air compressors meet this demand.

Mining industry
ROBUSTNESS AND RELIABILITY
Compressed air is vital for the mining industry: applications include dust
bad filtration, service air, ventilation air and pneumatic tools.
The reliability and robustness of GA compressors will accomplish the
job even in the harshest conditions.

Power plants
SMOOTH AND COST-EFFECTIVE OPERATION
Power plants run round-the-clock to supply vital energy. A continuous
supply of compressed air is absolutely critical for trouble-free operation.
GA air compressors provide a reliable source of compressed air of
applications such as silt blowing and fly ash handling.

General industry
A SAFE AND RELIABLE POWER SOURCE
Many industrial companies use compressed air in their daily operations.
Applications include pneumatic tools for cutting, drilling, hammering
and grinding, pneumatic actuators and valves, ventilation systems,
packing and palleting machinery and conveyer systems.
GA compressors are designed for ultimate performance and reliability.
Keeping your production
up and running
GA compressors ensure long and trouble-free lifetime at
the lowest operating cost. At their heart are state-of-the-art
compression elements based on innovative asymmetric rotor
profiles and powered by a high efficiency electric motor.
Combined with a built-to-last drive system and heavy duty air
inlet filters, this results in maximum reliability to operate in the
toughest conditions.

Reducing your production costs


The innovative design of GA compressors reduces your energy
bill and overall compressor lifecycle costs. GA compressors
are pre-assembled packages: installation is fault-free,
commissioning time is low and no external instrumentation
air is required.

Protecting your process


The integrated water separator immediately removes 100% of the
condensate, resulting in higher air quality.

Maximizing your savings


As there is no “one size fits all” concept, we have developed
a range of features and options to help you optimize the use
of your compressor: from running the machine at high
temperatures, to extra safety devices.
Twin element series for highest
efficiency and reliability

1
Practical cooler cleaning
• Hinged fans, fan motors and cowls for easy cooler cleaning.
• Twin fans for optimal cooling.
• Axial cooling fans driven by separate TEFC electric motors (IP55 protection).

2
Superior air quality
• 3-step efficient oil separation process for low residual
4
oil content in the compressed air (less than 3 ppm)
• Hinged cover for easy separator element change
1
5
2
6

3
Protective air filtration
• Protects the compressor components by removing 99.9% of dirt particles
down to 3 microns.
• Extends the system lifetime
7
Elektronikon unit controller
• High resolution color display gives you an easy to understand
readout of the equipment’s running conditions.
• Clear icons and intuitive navigation provides you fast access to
all of the important settings and data.
• Monitoring of the equipment running conditions and
maintenance status.

6
Energy recovery
• The optional energy recovery system can

3
recover up to 75% of the compressor’s shaft
power as hot water.
• The main module of the recovery system is
integrated in the compressor.

7 • Recovered hot water can be used as preheated


boiler feed water, space heating, showering or
other industrial applications.

5
Twin element on single drive & gear casing
• Efficiencies far superior to designs using one large element or 2-stages.
• Extended lifetime due to reduced loads on bearings, rotors and gears.
• Highly efficient motor – TEFC protection (IP55), class F insulation.

4
Moisture separator as standard
A cyclonic moisture separator, with automatic and manual drain,
mounted as standard, after the cooler block.
Optimize your system
With the GA 355-500, we provide an all-in-one solution incorporating the latest technology in a built-to-last
design. To further optimize the performance of your GA or to simply tailor it to your specific production
environment, optional features are available.

Standard scope of supply Additional features & options


Air intake filter Energy Recovery (on water-cooled versions only)
Air intake valve Electronic water drain
Air circuit Air/oil separator Phase sequence relay
PT1000 thermal protection for main motor
Aftercooler/oil cooler (air or water-cooled)
Anti-condensate heaters for main motor
Cooling fan for air-cooled units
Anchor pads
Ventilation fan for water-cooled units
Performance test certificate
Cooling circuit Water separators
Witness test
Oil circuit Oil filters
Material certificates
Complete air/oil/water circuit Sea worthy packing
IP55, Class F drive motor SPM monitoring
Built-in electrical starters (on low voltage variants) High short circuit current rating (HSCCR)
Flexible vibration dampers Heavy-duty filter
Elektronikon® control system Medium voltage motor
Full load/no load regulation system
Silencing canopy
Single point inlet and outlet connections
Structural steel skid - no foundations needed
SMARTLINK
Medium voltage motor
General NPT or ANSI connections

GA 355-500 Flow Diagram


Air In
Air Out

Incoming air

Outgoing air

Air/oil mixture

Water

Oil
Technical specifications
Maximum working pressure Capacity FAD (1) Installed Noise level
Compressor Weight (3)
motor (2), (3)
type Pack Pack
bar(e) psig l/s m3/ min cfm kW dB(A) kg lb
50 Hz
GA 355 - 7.5 7.5 109 1050 63.1 2225 355 73 8402 18523
GA 355 - 8.5 8.5 123 969 58.2 2053 355 73 8402 18523
GA 355 - 10 10 145 890 53.5 1886 355 73 8402 18523
GA 355 - 13 13 189 731 43.9 1549 355 73 8402 18523
GA 400 - 7.5 7.5 109 1175 70.6 2490 400 74 8602 18964
GA 400 - 8.5 8.5 123 1109 66.6 2350 400 74 8602 18964
GA 400 - 10 10 145 1011 60.8 2142 400 74 8602 18964
GA 400 - 13 13 189 844 50.7 1788 400 74 8602 18964
GA 450 - 7.5 7.5 109 1298 78.0 2750 450 75 8702 19185
GA 450 - 8.5 8.5 123 1240 74.5 2628 450 75 8702 19185
GA 450 - 10 10 145 1144 68.8 2424 450 75 8702 19185
GA 450 - 13 13 189 960 57.7 2034 450 75 8702 19185
GA 500 - 7.5 7.5 109 1410 84.7 2988 500 76 8202 18082
GA 500 - 8.5 8.5 123 1347 80.9 2854 500 76 8202 18082
GA 500 - 10 10 145 1257 75.5 2664 500 76 8202 18082
GA 500 - 13 13 189 1068 64.2 2263 500 76 8202 18082

GA 500 figures are for medium voltage IP 23 motor. (1) Unit performance measure according to ISO 1217, (2) Noise level
Annex C, Edition 4 (2009), FAD is measured at the A-weighted emission sound pressure level at the work
Reference conditions: following working pressures: station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Absolute inlet pressure 1 bar (14.5 psi) • 7.5 bar variants at 7 bar Values determined according to noise level test code ISO
Intake air temperature 20°C (68°F) • 8.5 bar variants at 8 bar 2151 and noise measurement standard ISO 9614.
Cooling medium temperature 20°C (68°F) • 10 bar variants at 9.5 bar
• 13 bar variants at 12.5 bar (3) Water-cooled models

Maximum working pressure Capacity FAD (1) Installed Noise level


Compressor Weight (3)
motor (2), (3)
type Pack Pack
bar(e) psig l/s m3/ min cfm hp dB(A) kg lb
60 Hz
GA 355-100 7.4 107 1032 62.1 2191 450 73 8102 17862
GA 355-125 9.1 132 940 56.5 1992 450 73 8102 17862
GA 355-150 10.8 157 831 49.9 1761 450 73 8102 17862
GA 355-200 13.8 200 692 41.6 1466 450 73 8102 17862
GA 400-100 7.4 107 1128 67.9 2394 500 74 8202 18082
GA 400-125 9.1 132 1042 62.6 2208 500 74 8202 18082
GA 400-150 10.8 157 935 56.2 1981 500 74 8202 18082
GA 400-200 13.8 200 784 47.1 1661 500 74 8202 18082
GA 450-100 7.4 107 1334 80.4 2835 600 75 8352 18413
GA 450-125 9.1 132 1222 73.4 2589 600 75 8352 18413
GA 450-150 10.8 157 1126 67.7 2386 600 75 8352 18413
GA 450-200 13.8 200 943 56.7 1998 600 75 8352 18413
GA 500-100 7.4 107 1518 91.2 3217 700 76 8002 17641
GA 500-125 9.1 132 1404 84.4 2975 700 76 8002 17641
GA 500-150 10.8 157 1296 77.9 2746 700 76 8002 17641
GA 500-200 13.8 200 1114 66.9 2361 700 76 8002 17641

GA 500 figures are for medium voltage IP 23 motor. (1) Unit performance measure according to ISO 1217, 2) Noise level
Annex C, Edition 4 (2009), FAD is measured at the A-weighted emission sound pressure level at the work
Reference conditions: following working pressures: station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Absolute inlet pressure 1 bar (14.5 psi) • 100 psi variants at 100 psi Values determined according to noise level test code ISO
Intake air temperature 20°C (68°F) • 125 psi variants at 125 psi 2151 and noise measurement standard ISO 9614.
Cooling medium temperature 20°C (68°F) • 150 psi variants at 150 psi
• 200 psi variants at 193 psi (3) Water-cooled models

Compressor L W H
type mm inch mm inch mm inch
GA 355-500 A (LV and MV-IP23) 5855 230.5 2120 83.5 2500 98.4 H
GA 355-500 A (MV-IP55) 6055 238.4 2120 83.5 2500 98.4
GA 355-500 W (LV and MV-IP23) 4000 157.5 2120 83.5 2500 98.4
GA 355-500 W (MV-IP55) 4200 165.4 2120 83.5 2500 98.4
A = air-cooled LV = low voltage
W = water-cooled MV = medium voltage
W L
2935 0368 19 © 2017, Atlas Copco, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the
environment and the people around us. We make performance stand
the test of time. This is what we call – Sustainable Productivity.

www.atlascopco.com
Oil-injected rotary
screw compressors

GA 355-500 (355-500 kW / 450-700 hp)


Outstanding performance
GA 355-500 compressors provide high-quality compressed air in the harshest environmental conditions.
Incorporating the patented Atlas Copco’s oil-injected screw element, they provide a long and trouble-free
life at the lowest possible operating cost.

Metal industry
QUALITY AND EFFICIENCY
Metal plants use compressed air for instrumentation, plant air and
pneumatic conveying for raw materials or ash and are in need of
an efficient solution to reduce their operating costs. Thanks to their
innovative features, our GA air compressors meet this demand.

Mining industry
ROBUSTNESS AND RELIABILITY
Compressed air is vital for the mining industry: applications include dust
bad filtration, service air, ventilation air and pneumatic tools.
The reliability and robustness of GA compressors will accomplish the
job even in the harshest conditions.

Power plants
SMOOTH AND COST-EFFECTIVE OPERATION
Power plants run round-the-clock to supply vital energy. A continuous
supply of compressed air is absolutely critical for trouble-free operation.
GA air compressors provide a reliable source of compressed air of
applications such as silt blowing and fly ash handling.

General industry
A SAFE AND RELIABLE POWER SOURCE
Many industrial companies use compressed air in their daily operations.
Applications include pneumatic tools for cutting, drilling, hammering
and grinding, pneumatic actuators and valves, ventilation systems,
packing and palleting machinery and conveyer systems.
GA compressors are designed for ultimate performance and reliability.
Keeping your production
up and running
GA compressors ensure long and trouble-free lifetime at
the lowest operating cost. At their heart are state-of-the-art
compression elements based on innovative asymmetric rotor
profiles and powered by a high efficiency electric motor.
Combined with a built-to-last drive system and heavy duty air
inlet filters, this results in maximum reliability to operate in the
toughest conditions.

Reducing your production costs


The innovative design of GA compressors reduces your energy
bill and overall compressor lifecycle costs. GA compressors
are pre-assembled packages: installation is fault-free,
commissioning time is low and no external instrumentation
air is required.

Protecting your process


The integrated water separator immediately removes 100% of the
condensate, resulting in higher air quality.

Maximizing your savings


As there is no “one size fits all” concept, we have developed
a range of features and options to help you optimize the use
of your compressor: from running the machine at high
temperatures, to extra safety devices.
Twin element series for highest
efficiency and reliability

1
Practical cooler cleaning
• Hinged fans, fan motors and cowls for easy cooler cleaning.
• Twin fans for optimal cooling.
• Axial cooling fans driven by separate TEFC electric motors (IP55 protection).

2
Superior air quality
• 3-step efficient oil separation process for low residual
4
oil content in the compressed air (less than 3 ppm)
• Hinged cover for easy separator element change
1
5
2
6

3
Protective air filtration
• Protects the compressor components by removing 99.9% of dirt particles
down to 3 microns.
• Extends the system lifetime
7
Elektronikon unit controller
• High resolution color display gives you an easy to understand
readout of the equipment’s running conditions.
• Clear icons and intuitive navigation provides you fast access to
all of the important settings and data.
• Monitoring of the equipment running conditions and
maintenance status.

6
Energy recovery
• The optional energy recovery system can

3
recover up to 75% of the compressor’s shaft
power as hot water.
• The main module of the recovery system is
integrated in the compressor.

7 • Recovered hot water can be used as preheated


boiler feed water, space heating, showering or
other industrial applications.

5
Twin element on single drive & gear casing
• Efficiencies far superior to designs using one large element or 2-stages.
• Extended lifetime due to reduced loads on bearings, rotors and gears.
• Highly efficient motor – TEFC protection (IP55), class F insulation.

4
Moisture separator as standard
A cyclonic moisture separator, with automatic and manual drain,
mounted as standard, after the cooler block.
Optimize your system
With the GA 355-500, we provide an all-in-one solution incorporating the latest technology in a built-to-last
design. To further optimize the performance of your GA or to simply tailor it to your specific production
environment, optional features are available.

Standard scope of supply Additional features & options


Air intake filter Energy Recovery (on water-cooled versions only)
Air intake valve Electronic water drain
Air circuit Air/oil separator Phase sequence relay
PT1000 thermal protection for main motor
Aftercooler/oil cooler (air or water-cooled)
Anti-condensate heaters for main motor
Cooling fan for air-cooled units
Anchor pads
Ventilation fan for water-cooled units
Performance test certificate
Cooling circuit Water separators
Witness test
Oil circuit Oil filters
Material certificates
Complete air/oil/water circuit Sea worthy packing
IP55, Class F drive motor SPM monitoring
Built-in electrical starters (on low voltage variants) High short circuit current rating (HSCCR)
Flexible vibration dampers Heavy-duty filter
Elektronikon® control system Medium voltage motor
Full load/no load regulation system
Silencing canopy
Single point inlet and outlet connections
Structural steel skid - no foundations needed
SMARTLINK
Medium voltage motor
General NPT or ANSI connections

GA 355-500 Flow Diagram


Air In
Air Out

Incoming air

Outgoing air

Air/oil mixture

Water

Oil
Technical specifications
Maximum working pressure Capacity FAD (1) Installed Noise level
Compressor Weight (3)
motor (2), (3)
type Pack Pack
bar(e) psig l/s m3/ min cfm kW dB(A) kg lb
50 Hz
GA 355 - 7.5 7.5 109 1050 63.1 2225 355 73 8402 18523
GA 355 - 8.5 8.5 123 969 58.2 2053 355 73 8402 18523
GA 355 - 10 10 145 890 53.5 1886 355 73 8402 18523
GA 355 - 13 13 189 731 43.9 1549 355 73 8402 18523
GA 400 - 7.5 7.5 109 1175 70.6 2490 400 74 8602 18964
GA 400 - 8.5 8.5 123 1109 66.6 2350 400 74 8602 18964
GA 400 - 10 10 145 1011 60.8 2142 400 74 8602 18964
GA 400 - 13 13 189 844 50.7 1788 400 74 8602 18964
GA 450 - 7.5 7.5 109 1298 78.0 2750 450 75 8702 19185
GA 450 - 8.5 8.5 123 1240 74.5 2628 450 75 8702 19185
GA 450 - 10 10 145 1144 68.8 2424 450 75 8702 19185
GA 450 - 13 13 189 960 57.7 2034 450 75 8702 19185
GA 500 - 7.5 7.5 109 1410 84.7 2988 500 76 8202 18082
GA 500 - 8.5 8.5 123 1347 80.9 2854 500 76 8202 18082
GA 500 - 10 10 145 1257 75.5 2664 500 76 8202 18082
GA 500 - 13 13 189 1068 64.2 2263 500 76 8202 18082

GA 500 figures are for medium voltage IP 23 motor. (1) Unit performance measure according to ISO 1217, (2) Noise level
Annex C, Edition 4 (2009), FAD is measured at the A-weighted emission sound pressure level at the work
Reference conditions: following working pressures: station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Absolute inlet pressure 1 bar (14.5 psi) • 7.5 bar variants at 7 bar Values determined according to noise level test code ISO
Intake air temperature 20°C (68°F) • 8.5 bar variants at 8 bar 2151 and noise measurement standard ISO 9614.
Cooling medium temperature 20°C (68°F) • 10 bar variants at 9.5 bar
• 13 bar variants at 12.5 bar (3) Water-cooled models

Maximum working pressure Capacity FAD (1) Installed Noise level


Compressor Weight (3)
motor (2), (3)
type Pack Pack
bar(e) psig l/s m3/ min cfm hp dB(A) kg lb
60 Hz
GA 355-100 7.4 107 1032 62.1 2191 450 73 8102 17862
GA 355-125 9.1 132 940 56.5 1992 450 73 8102 17862
GA 355-150 10.8 157 831 49.9 1761 450 73 8102 17862
GA 355-200 13.8 200 692 41.6 1466 450 73 8102 17862
GA 400-100 7.4 107 1128 67.9 2394 500 74 8202 18082
GA 400-125 9.1 132 1042 62.6 2208 500 74 8202 18082
GA 400-150 10.8 157 935 56.2 1981 500 74 8202 18082
GA 400-200 13.8 200 784 47.1 1661 500 74 8202 18082
GA 450-100 7.4 107 1334 80.4 2835 600 75 8352 18413
GA 450-125 9.1 132 1222 73.4 2589 600 75 8352 18413
GA 450-150 10.8 157 1126 67.7 2386 600 75 8352 18413
GA 450-200 13.8 200 943 56.7 1998 600 75 8352 18413
GA 500-100 7.4 107 1518 91.2 3217 700 76 8002 17641
GA 500-125 9.1 132 1404 84.4 2975 700 76 8002 17641
GA 500-150 10.8 157 1296 77.9 2746 700 76 8002 17641
GA 500-200 13.8 200 1114 66.9 2361 700 76 8002 17641

GA 500 figures are for medium voltage IP 23 motor. (1) Unit performance measure according to ISO 1217, 2) Noise level
Annex C, Edition 4 (2009), FAD is measured at the A-weighted emission sound pressure level at the work
Reference conditions: following working pressures: station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Absolute inlet pressure 1 bar (14.5 psi) • 100 psi variants at 100 psi Values determined according to noise level test code ISO
Intake air temperature 20°C (68°F) • 125 psi variants at 125 psi 2151 and noise measurement standard ISO 9614.
Cooling medium temperature 20°C (68°F) • 150 psi variants at 150 psi
• 200 psi variants at 193 psi (3) Water-cooled models

Compressor L W H
type mm inch mm inch mm inch
GA 355-500 A (LV and MV-IP23) 5855 230.5 2120 83.5 2500 98.4 H
GA 355-500 A (MV-IP55) 6055 238.4 2120 83.5 2500 98.4
GA 355-500 W (LV and MV-IP23) 4000 157.5 2120 83.5 2500 98.4
GA 355-500 W (MV-IP55) 4200 165.4 2120 83.5 2500 98.4
A = air-cooled LV = low voltage
W = water-cooled MV = medium voltage
W L
2935 0368 19 © 2017, Atlas Copco, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the
environment and the people around us. We make performance stand
the test of time. This is what we call – Sustainable Productivity.

www.atlascopco.com
OIL-INJECTED ROTARY
SCREW COMPRESSORS
GA 5-11 (5,5-11 kW/7,5-15 hp)
Highest reliability
The GA series is designed, manufactured and tested in
accordance with ISO 9001, ISO 14001 and ISO 1217, Ed. 4,
Annex C/E. Ensuring a long and trouble-free life at the

THE ULTIMATE
lowest operating cost, the GA contains the latest generation
of Atlas Copco’s innovative oil-injected screw element.

SMART SOLUTION Minimized energy costs


THAT FITS Energy can represent over 80% of a compressor’s life cycle costs
(LCC). The generation of compressed air can even account for
Atlas Copco’s GA compressors bring outstanding more than 40% of a plant’s total electricity bill. Through the use
of Atlas Copco’s highly efficient element and state-of-the-art
performance, flexible operation and high
packaging, GA compressors can minimize energy costs and
productivity, while minimizing the total cost of the overall compressor life cycle costs.
ownership. With this premium compressor series
you will certainly find the compressed air solution Air system integration
that perfectly matches your specific requirements. The GA WorkPlace Air System can be installed close to the point
Through products that are built to perform in even of use thanks to its low noise operation. In addition, as air
treatment equipment is integrated and the tank is mounted
the harshest environments, Atlas Copco commits
under the compressor, the need for a separate compressor
to keeping your production running in the most room is eliminated. Moreover, all compressors are delivered
efficient way. ready for use, reducing installation costs to a minimum.
5
GA 5-11: THE PREMIUM SOLUTION High tech oil vessel
Able to tackle extreme duties as daily challenges, Atlas Copco’s high-performance • Protection from oil contamination: extremely low oil carry-over
tank mounted GA compressors beat any workshop solution. Ready to supply thanks to the vertical design of the oil vessel.

high-quality air, they keep the air network clean and your production up and running. • Extremely low losses of compressed air during load/unload cycle
thanks to minimized oil vessel size.

1
Optimized drive train
Unequaled reliability during the system’s lifetime
thanks to the belt-driven drive train developed in
accordance with the highest industry standards.

6
2

4
1
5 3 4

2 Elektronikon® controller
• Web based online compressor status viewer on new
Time proven Elektronikon® for remote monitoring using a standard
element Ethernet connection.
• The GA 5-11’s • The Elektronikon®’s monitoring features include new
compression element is combined with service and warning indications, error detection and
an IE3 efficiency motor, improved bearings compressor shut-down. The optional Elektronikon®
and seal arrangement resulting in minimized graphic controller provides further enhanced visual
energy costs. service indications and warnings.
• Fit for environments with ambient temperatures up to 46°C due
to superior component design.
• The Free Air Delivery is increased up to 8% and power consumption is
reduced by 7% thanks to optimized packaging and the state-of-the-art
compressor element.

6
Easy installation & servicing
3
• A true plug-and-play solution ready to be installed close
Integrated quality air solutions to the point of use.

• Protection of downstream air equipment in all working conditions: the integrated • Optionally, the system can be expanded with an integrated dryer,
dryer avoids condensation and corrosion in the network. air filters and a factory mounted 270L receiver (optional 500L).

• Additional energy savings with the dryer’s no-loss electronic drain. • Effortless transportation by forklift.

• Optional filters can be added to obtain air quality up to class 1 level (<0.01 ppm). • Standard equipped with a 3 meter power supply cable.

• Water separator included as standard. • Minimized service costs thanks to high-quality and easily
replaceable consumables with a long lifetime and easy servicing.
A STEP AHEAD IN MONITORING
AND CONTROLS
The next-generation Elektronikon® operating system offers a great variety of control and monitoring features Optional integrated compressor controller
to increase efficiency and reliability. The Elektronikon® controls the main drive motor and regulates system To reduce system pressure and energy consumption in installations of up to 4 (ES4i) or 6 (ES6i) compressors, the optional integrated
pressure within a predefined and narrow pressure band. compressor controller can be installed with a simple license.

Dual pressure set point & delayed second stop


Elektronikon controller
®
Key features The production process creates fluctuating levels of demand which can cause energy losses in low use periods. The Elektronikon®
can manually or automatically create two different system pressure bands to optimize energy use and reduce costs at low use times.
• Improved ease of use: intuitive navigation system with clear • Automatic restart after voltage failure.
In addition, the sophisticated Delayed Second Stop (DSS) runs the drive motor only when needed. As the desired system pressure
pictograms and extra 4th LED indicator for service. • Dual pressure set point.
is maintained while the drive motor’s run time is minimized, energy consumption is kept at a minimum.
• Free online compressor status visualization through a web • Delayed Second Stop function.
browser using a standard Ethernet connection.
• Option to upgrade to the advanced
• Easy to upgrade. Elektronikon® graphic controller.
• Maximum reliability: more durable keyboard.
Without DSS With DSS
Power Power

Loaded
Loaded Unloaded

Unloaded Stopped

Time Time
Free online visualization Saved energy
Monitor your compressors over the Ethernet with the
new Elektronikon® controllers. Monitoring features
include warning indications, compressor shut-down and Saver cycle
maintenance scheduling, all possible with the free online Saver cycle technology reduces energy consumption. to monitor the required dew point suppression, the dryer saver
compressor status visualization. SMS service, trending The Elektronikon® is linked to both saver cycles: fan and dryer. cycle starts and stops the dryer when the compressor has
and remote history events are optional through the Monitoring the oil temperature, the fan saver cycle regulates stopped, minimizing energy use and protecting the air system
connectivity program. the fan and minimizes energy use. Using an ambient sensor from corrosion.
EXCELLENCE IN QUALITY AIR TAILORED TO YOUR NEEDS
Untreated compressed air contains moisture, aerosols and dirt particles that can damage your air system Some applications may need or benefit from additional options,
and contaminate your end product. The resulting maintenance costs can far exceed air treatment costs. more refined control and air treatment systems. To meet these needs,
Our compressors provide the clean, dry air that improves your system’s reliability, avoiding costly Atlas Copco has developed options and easily integrated compatible
downtime and production delays, and safeguarding the quality of your products. Clean, treated air also equipment providing the lowest cost compressed air.
reduces the risk of corrosion and leaks in your compressed air system, leading to substantial cost savings.
Furthermore, with leaks and energy waste minimized and the unsafe disposal of untreated condensate
eliminated, you can protect the environment and conform to stringent international regulations.

GA 5-11

Integrated filter kit class 1 •


Integrated filter kit class 2 •
Dryer by-pass •
Integrated oil/water separator (OSD) •
Electronic water drain (EWD) on pack unit (cooler) •
500 liter air receiver •
Electronic water drain (EWD) on 500L vessel •
Savings features Integrated oil/water separator OSD •
On average 30% energy savings with new range Phase sequence relay •
of integrated dryers Tropical thermostat •
Freeze protection •
• Global warming potential has been reduced
Heavy duty inlet filter •
significantly by an average of 50% by reducing Rain protection •
the amount of refrigerant in the new dryer. Main power isolator switch •
Upgrade Elektronikon® graphic •
• Use of energy-efficient refrigerant R134a reduces
Relays for ES 100 sequence selector •
operating costs. Roto–Xtend duty oil •
• Environmentally friendly characteristics. Central Control license 4 (ES 4i) or 6 (ES 6i) machines on Elektronikon® graphic •
Modulating control •
• Unique Saver Cycle Control, with ambient temperature High ambient temperature versions •
sensor and based on dryer load and relative humidity Food-grade oil •
of compressed air, saves energy at partial load. Dryer Saver Cycle •
Compressor inlet Pre-filter •
• Low pressure drop heat exchanger with Motor space heater + thermistors •
integrated water separator.
: Standard • : Optional - : Not available
• Zero waste of compressed air thanks to no-loss
condensate drain.
• Pressure dew point of 3°C (100% relative
humidity at 20°C).

Energy-saving contributors

ISO quality class* Dirt particle size Water pressure dew point** Oil concentration Saver Cycle Control

Heat exchanger no-loss


3.-.4 3 microns - 2 ppm
condensate drain
3.4.4 3 microns +3ºC, 37ºF 2 ppm
Energy-efficient refrigerant
2.4.2 1 micron +3ºC, 37ºF 0.1 ppm

1.4.1 0.01 microns +3ºC, 37ºF 0.01 ppm


Low pressure drop

* The table values are maximum limits according to the respective ISO quality class.
** Water pressure dew point based on 100% RH at 20°C/68°F.
FLOW
GA 5-11 CHART TECHNICAL SPECIFICATIONS
GA 5-7-11
Weight (kg)
Working pressure Capacity FAD* Installed Noise
WorkPlace min-max motor power level**
10 COMPRESSOR WorkPlace WorkPlace Full Feature
21
2 17 TYPE
7 7
bar(e) psig l/s m3/h cfm kW hp dB(A) Floor-mounted Tank-mounted Floor-mounted Tank-mounted
3
1 50 Hz VERSION
23 GA 5 7.5 7.5 109 15.0 54.0 31.7 5.5 7.5 60 257 317 300 360
15 16 9
6 8.5 8.5 123 13.2 47.5 27.9 5.5 7.5 60 257 317 300 360
5 8
22 18 10 10 145 11.7 42.1 24.7 5.5 7.5 60 257 317 300 360
20
13 13 189 8.4 30.2 17.7 5.5 7.5 60 257 317 300 360
14
19 GA 7 7.5 7.5 109 21.0 78.5 46.0 7.5 10 61 270 330 315 375
11
8.5 8.5 123 19.6 70.6 41.5 7.5 10 61 270 330 315 375

13 10 10 145 17.2 61.9 36.3 7.5 10 61 270 330 315 375


4 12 13 13 189 14.2 51.1 30.0 7.5 10 61 270 330 315 375

GA 11 7.5 7.5 109 30.7 110.5 64.8 11 15 62 293 353 343 403

8.5 8.5 123 28.3 101.9 59.7 11 15 62 293 353 343 403

10 10 145 26.0 93.6 54.9 11 15 62 293 353 343 403

13 13 189 22.0 79.2 46.5 11 15 62 293 353 343 403

Max. Working Weight (kg)


Capacity FAD* Installed Noise
Intake air Water pressure
min-max motor power level**
COMPRESSOR WorkPlace WorkPlace WorkPlace Full Feature
TYPE
Air/oil mixture Refrigerant gas/liquid mixture bar(e) psig l/s m3/h cfm kW hp dB(A) Floor-mounted Tank-mounted Floor-mounted Tank-mounted

Oil High pressure, hot refrigerant gas 60 Hz VERSION


GA 5 100 7.4 107 15.0 54.0 31.7 5.5 7.5 60 257 317 300 360
Compressed air without free water Low pressure, cool refrigerant gas 125 9.1 132 13.2 47.5 27.9 5.5 7.5 60 257 317 300 360

150 10.8 157 11.7 42.1 24.7 5.5 7.5 60 257 317 300 360
Wet compressed air High pressure refrigerant liquid
175 12.5 181 8.4 30.2 17.7 5.5 7.5 60 257 317 300 360

GA 7 100 7.4 107 21.0 76.6 44.3 7.5 10 61 270 330 315 375
Dry compressed air Low pressure refrigerant liquid
125 9.1 132 19.9 71.7 42.0 7.5 10 61 270 330 315 375

150 10.8 157 17.2 61.9 36.3 7.5 10 61 270 330 315 375

175 12.5 181 14.2 51.1 30.0 7.5 10 61 270 330 315 375

GA 11 100 7.4 107 30.4 109.4 64.1 11 15 62 293 353 343 403

125 9.1 132 27.0 97.2 57.0 11 15 62 293 353 343 403

150 10.8 157 24.9 89.6 52.5 11 15 62 293 353 343 403

175 12.5 181 22.0 79.2 46.4 11 15 62 293 353 343 403

* Unit performance measured according to ISO 1217, Ed. 4, Annex C-2009.


** Mean noise level measured at a distance of 1 m according to ISO 2151; tolerance 3 dB(A).

Reference conditions:
Air flow Oil flow Refrigerant flow - Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20ºC, 68ºF.

FAD is measured at the following working pressures:


1. Air intake filter 12. Oil 17. Refrigerant compressor - 7.5 bar versions at 7 bar(e).
- 8.5 bar versions at 8 bar(e).
2. Air intake valve 13. Oil cooler 18. Condenser - 10 bar versions at 9.5 bar(e). W: 699 mm
L2: 1142 mm
- 13 bar versions at 12.5 bar(e).
3. Compression element 14. Thermostatic bypass valve 19. Liquid refrigerant dryer/filter
4. Air/oil separator vessel 15. Oil separator 20. Capilar
5. Minimum pressure valve 16. Oil filter 21. Evaporator
6. After-cooler 22. Hot gas bypass valve H: 1729 mm H2: 1240 mm

7. Air-air heat exchanger 23. Air intake valve GA 5-7-11 pack (floor-mounted)
8. Water separator (pack only) H: 1240 mm

9. Water separator with drain GA 5-7-11 pack (tank-mounted)


10. DD/PD filters
11. Air receiver
W: 699 mm
L: 1142 mm L: 1498 mm

Floor-mounted Tank-mounted
2935 0875 46 © 2015, Atlas Copco Airpower NV, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the environment and the
people around us. We make performance stand the test of time. This is what we call –
Sustainable Productivity.

www.atlascopco.com
Oil-injected
COMPRESORES
DE TORNILLO
rotary screw
ROTATIVOS
compressors
CON INYECCIÓN
GA 7-75 VSD+ (7-75 kW/10-100 hp)

DE ACEITE
GA 7-75 VSD+ (7-75 kW/10-100 CV)
The new
revolutionary
compressor from
Atlas Copco
With its innovative vertical design, Atlas Copco’s
GA 7-75 VSD+ brings a game-changing revolution
in the compressor industry. It offers Variable
Speed Drive as standard, a compact motor and
footprint thanks to its in-house design and iPM
(Permanent Magnet) technology. The GA 7-75 VSD+
reduces energy consumption by on average
50%, with uptimes assured even in the harshest
operational conditions. The GA 7-75 VSD+ is the air
compressor of the future, designed in-house by
Atlas Copco. It will set a new standard for years to
come, positioning Atlas Copco as a leader in the
compressed air industry.
Innovative
Atlas Copco has turned the compressed air industry on its
head by redesigning the conventional layout of a typical air
compressor. Instead of the normal space-taking horizontal
design, the new GA 7-75 VSD+ has an upright, vertical, low
footprint layout. This saves valuable floor and work space,
eases maintenance access, accelerates manufacturing time,
and reduces the total cost of ownership for all customers.

Efficient
• On average 15% lower Specific Energy Requirement (SER)
than the current GA VSD models. Eco-efficient VSD+ reduces
energy consumption by on average 50% compared to the VSD
current idling models.
• On top of energy savings, Free Air Delivery (FAD)
increase of up to 12% over the range.
• Efficient fan motor below 37 kW (ERP 2015) reduces
electricity consumption and noise levels.
• IE4 motor efficiency (iPM), outperforming
IE3 efficiency levels.

Reliable
• Low maintenance: fewer components, increased uptime.
• Worry-free: the GA 7-75 VSD+ has been extensively
field-tested.
• Based on unique combination of proven technologies and
existing components, optimally brought together by
Atlas Copco’s unique experience and know-how.

Smart
• Elegant and revolutionary design.
• Extra compact footprint.
• Fewer components & few options: impressive list
of standard features.
• Ecological design, efficient material usage.
INSIDE THE INNOVATIVE GA 7-37 VSD+

DRIVE TRAIN

1
Interior Permanent Magnet (IPM) motor
• Very high efficiency: IE4. 4
• Compact, customized design for optimal cooling by oil.
• Designed in-house in Belgium.
• IP66 vs. IP55.
• No cooling air flow required.
• Oil-lubricated motor bearing: no (re)grease(ing), increased uptime.

2 7
Element
• Made by Atlas Copco.
• Robust and silent.

1
3 8

3
Direct drive
• Vertical design, fewer parts.
• Oil-cooled, pressure-tight.
• No gears or belts, no shaft seal.
• Compact: footprint down 60%.
4
Innovative fan
• Based on the newest technologies.
• In compliance with ERP2015 efficiency.
• Low noise levels.

5
Robust oil filter/separator
• Integrated bypass valve with the oil filter.

6 • Easy maintenance.

6
Electronic no-loss water drain
5 • Included as standard.
• Efficient removal of condensate without
loss of compressed air.
• Manual integrated bypass for effective condensate
removal in case of power failure.

7
Elektronikon® controller
9 • Integrated smart algorithms reduce system pressure
and energy consumption.
• Warning indications, maintenance scheduling
and online status visualization.
• Graphic display of key parameters (day, week, month)
and 32 language settings.

9 8
VSD+ cubicle Sentinel valve
• VSD+ superior to idling machines. • No inlet arrestor.
• Electrical components remain cool, • No blow off losses.
enhancing lifetime of components. • Maintenance free.
• Dedicated drive for iPM technology motors.
• 5% DC choke as standard.
• Heat dissipation of inverter in separate compartment.
INSIDE THE ROBUST GA 37-75 VSD+

2
8

DRIVE TRAIN

1
Interior Permanent Magnet (IPM) motor
• Oil cooled motor.
• Optimal cooling for all speeds and ambient conditions.
• Designed in-house in Belgium.
• Oil-lubricated motor bearing: no (re)grease(ing), increased uptime.
• IP66: pressure tight.
11 11
• Permanent magnets.

2
New compressor element
• New improved rotor profile.
• Reduced pressure losses.
• Optimized in and outlet portals.

3 4
Direct drive Inlet filter
• Vertical design, less parts. • Heavy duty.
• Oil-cooled, pressure-tight. • Maintenance every 4,000 hours.
• No gears or belts, no shaft seal. • Pressure drop indicator.
5
Radial fan
• Compact.
• Low noise level.
• High capacity for optimized cooling.

6
Classic cooler design
• Integrated water separation.
• Separate oil/air cooler.
• Easy access for maintenance.

7
Neos Inverter
• Cool cubicle: no cooling fans needed.
• Fully enclosed: no dust ingress possible.

5 • External heatsink with separate cooling.

8
9
6 Integrated dryer
• Extra compact footprint.
• Refrigerant R410A.

1
3 7

10

2
9
Elektronikon® controller
• Integrated smart algorithms reduce system
pressure and energy consumption.
• Monitoring features include warning indications,
maintenance scheduling and online visualization
11 of machine’s condition.
VSD+ cubicle
• VSD+ superior to idling machines.
10
• Electrical components remain cool,
enhancing lifetime of components. Sentinel valve
• Dedicated drive for iPM technology motors. • Optimizing the inlet flow of the air end.
• 5% DC choke as standard. • No blow off losses.
• Heat dissipation of inverter in separate compartment. • Full aluminum design: maintenance free.
VSD+ FOR 50% AVERAGE ENERGY SAVINGS
Atlas Copco’s GA Variable Speed Drive+ (VSD+) technology closely matches the air
demand by automatically adjusting the motor speed. Combined with the innovative
design of the iPM (Permanent Magnet) motor, this results in average energy savings of
50% and an average cut of 37% in the lifecycle cost of a compressor. VSD+ works with
permanent, in-house designed permanent magnet motors.

Why Atlas Copco Variable Speed Drive+ technology?


• On average 50% energy savings with an extensive flow range (20-100%).
• Integrated Elektronikon® Graphic controller controls the motor speed and high efficiency frequency inverter.
• No wasted idling times or blow-off losses during operation.
• Compressor can start/stop under full system pressure without the need to unload with special VSD+ motor.
• Eliminates peak current penalty during start-up.
• Minimizes system leakage due to a lower system pressure.
• EMC Compliance to directives (2004/108/EG).
* Compared to fixed speed compressors, based on measurement performed by an independent energy audit agency.
In almost every production environment, air demand fluctuates depending on different factors such
as the time of the day, week or even month. Extensive measurements and studies of compressed air
demand profiles show that many compressors have substantial variations in air demand.

Air demand Energy consumption

Time
Air demand Energy consumption
Fixed speed load/unload

Air demand Energy consumption

Time
Air demand GA VSD+ energy consumption

50% SAVINGS

GA Fixed Speed GA VSD+

Energy Investment Maintenance

* Compared to fixed speed compressors, based on measurement performed by an independent energy audit agency.
A STEP AHEAD IN MONITORING
AND CONTROLS
The next-generation Elektronikon® operating system offers a wide variety of control and monitoring
features that allow you to increase your compressor’s efficiency and reliability. To maximize energy
efficiency, the Elektronikon® controls the main drive motor and regulates system pressure within
a predefined and narrow pressure band.

Dual pressure set point


Most production processes create fluctuating demands which, in turn, can create
energy waste in low use periods. Using the Elektronikon®, you can manually
or automatically create two different system pressure bands to optimize energy
use and reduce costs.

Integrated Saver Cycles


Fan Saver Cycle reduces the energy consumption by switching off the fan
in light load applications. Using an ambient sensor to monitor the required
dew point suppression, the Elektronikon® starts and stops the dryer,
minimizing energy use.

Week timer
An on-board clock enables timers to be set up to support any working scheme –
per day, per week or completely customizable to your specific situation and needs.
EXCELLENCE IN INTEGRATED AIR QUALITY
Untreated compressed air contains moisture and aerosols which increase the risk of corrosion and
compressed air system leaks. This can result in a damaged air system and contaminated end product.
Maintenance costs can far exceed air treatment costs. Our compressors provide the clean, dry air that
improves your system’s reliability, avoids costly downtime and production delays, and safeguards
the quality of your products.

Save money and the environment


Avoid risk of corrosion and system leaks, and ensure the effective safe disposal of untreated condensate – all within ISO 14001 standards.

On average 50% energy savings with newly


designed integrated dryers
• Pressure dew point of 3°C (100% relative humidity at 20°C).
• Heat exchanger cross-flow technology with low pressure drop.
• Zero waste of compressed air thanks to no-loss condensate drain.
• Reduced operating costs.
• Environmentally-friendly characteristics; zero ozone depletion.
• Global warming potential has been reduced significantly by an average
of 50% by reducing the amount of refrigerant in the new dryer.

SMARTLINK*: Data Monitoring Program


• Remote monitoring system that helps you optimize your compressed air system and save energy and costs.
• Provides a complete insight in your compressed air network.
• Anticipates on potential problems by warning you up-front.
* Please contact your local sales representative for more information.
TECHNICAL SPECIFICATIONS GA 7-37 VSD+
Weight
Weight
Working pressure Capacity FAD* (min-max) Installed motor power Noise level** WorkPlace
Type WorkPlace
Full Feature

bar(e) psig l/s m³/h cfm kW hp dB(A) kg kg


50/60 Hz version
5.5 80 7.2-21.9 25.9-78.8 15.2-46.4 7.5 10 62 193 277
7 102 7.0-21.7 25.2-78.1 14.8-46.0 7.5 10 62 193 277
GA 7 VSD +

9.5 138 6.8-18.0 24.5-64.8 14.4-38.1 7.5 10 62 193 277


12.5 181 7.3-14.2 26.3-51.12 15.5-30.1 7.5 10 62 193 277
5.5 80 7.3-32.9 26.3-118.4 15.5-69.7 11 15 63 196 280
7 102 7.3-32.5 26.3-117.0 15.5-68.8 11 15 63 196 280
GA 11 VSD +
9.5 138 7.0-27.2 25.2-97.9 14.8-57.6 11 15 63 196 280
12.5 181 7.6-23.5 27.4-84.6 16.1-49.8 11 15 63 196 280
5.5 80 7.2-42.3 25.9-152.3 15.2-89.6 15 20 64 199 288
7 102 7.1-41.8 25.6-150.5 15.0-88.6 15 20 64 199 288
GA 15 VSD +
9.5 138 6.8-35.5 24.5-127.8 14.4-75.2 15 20 64 199 288
12.5 181 7.3-27.9 26.3-100.4 15.5-59.1 15 20 64 199 288
4 58 15.0 - 63.2 53.9 - 227.5 31.7 - 133.8 18 25 67 367 480
7 102 14.7 - 61.8 53.0 - 222.6 31.2 - 131.0 18 25 67 367 480
GA 18 VSD +
9.5 138 16.9 - 53.0 61.0 - 190.8 35.9 - 112.3 18 25 67 367 480
12.5 181 16.3 - 43.0 58.5 - 154.8 34.4 - 91.1 18 25 67 367 480
4 58 15.2 - 76.1 54.6 - 274.0 32.1 - 161.2 22 30 67 363 485
7 102 14.8 - 74.3 53.3 - 267.6 31.3 - 157.4 22 30 67 363 485
GA 22 VSD +
9.5 138 17.1 - 64.5 61.5 - 232.1 36.2 - 136.6 22 30 67 363 485
12.5 181 16.9 - 53.5 60.7 - 192.5 35.7 - 113.2 22 30 67 363 485
4 58 14.8 - 85.8 53.2 - 309.0 31.3 - 181.8 26 35 67 373 490
7 102 14.5 - 85.3 52.1 - 307.2 30.6 - 180.7 26 35 67 373 490
GA 26 VSD+
9.5 138 16.9 - 77.9 60.7 - 280.5 35.7 - 165.1 26 35 67 373 490
12.5 181 16.3 - 64.1 58.8 - 230.8 34.6 - 135.8 26 35 67 373 490
4 58 15.1 - 98.0 54.3 - 352.8 31.9 - 207.6 30 40 67 376 500
7 102 15.0 - 97.4 54.1 - 350.5 31.8 - 206.2 30 40 67 376 500
GA 30 VSD+
9.5 138 17.2 - 85.6 61.7 - 308.2 36.3 - 181.3 30 40 67 376 500
12.5 181 16.7 - 72.0 60.0 - 259.1 35.3 - 152.4 30 40 67 376 500
4 58 15.3 - 116.4 55.1 - 418.9 32.4 - 246.4 37 50 67 376 500
7 102 14.8 - 114.8 53.2 - 413.2 31.3 - 243.1 37 50 67 376 500
GA 37 VSD+
9.5 138 17.1 - 102.1 61.5 - 367.7 36.2 - 216.3 37 50 67 376 500
12.5 181 16.4 - 86.6 58.9 - 311.8 34.6 - 183.4 37 50 67 376 500

* Unit performance measured according ISO 1217 ed. 4 2009, annex E, latest edition. FAD is measured at the following effective working pressures:
** Mean noise level measured at a distance of 1 m according to ISO 2151: 2004 using - 4 bar(e) (GA 18-37 VSD+)
ISO 9614/2 (sound intensity method); tolerance 3 dB(A). - 5.5 bar(e) (GA 7-15 VSD+)
- 7 bar(e)
Reference conditions: - 9.5 bar(e)
- Absolute inlet pressure 1 bar (14.5 psi). - 12.5 bar(e)
- Intake air temperature 20°C, 68°F. Maximum working pressure: 13 bar(e) (188 psig)

Options
Energy recovery DD+ filter
Dryer bypass FoodGrade oil
Main switch Elektronikon connectivity (SmartBox)
Freeze protection UD+ filter
H
Heavy duty inlet filter RXD oil
Pre-filter ES4i, ES6i
Tropical thermostat Transformer sales kit 200-230V / 500-575V
IT-ancillaries

D W

Standard Full Feature


DIMENSIONS
D (mm) W (mm) H (mm) D (in) W (in) H (in) D (mm) W (mm) H (mm) D (in) W (in) H (in)
GA 7-15 VSD+ 630 610 1420 24.80 24.02 55.91 630 985 1420 24.80 38.78 55.91
GA 18-37 VSD+ 780 811 1590 30.71 31.93 62.60 780 1273 1590 30.71 50.12 62.60
FLOW CHART GA 7-37 VSD+

16

14

13

12

15* 9
7
8
17 10

11
1
1
6
4

2
3

1 Inlet filter 10 Minimum pressure valve Wet compressed air


2 Sentinel valve 11 Solenoid valve
Condensate
3 Screw element 12 After cooler
4 Interior permanent magnet motor (iPM) 13 Fan Dry compressed air
5 Air/oil vessel separator 14 Oil cooler
6 Thermostatic bypass valve 15 Electronic drain (* mounted on Intake air
7 Oil filter after-cooler on models without dryer)
Air/oil mixture
8 Safety valve 16 Dryer (Full Feature option)
9 Oil separator 17 Condensate prevention cycle Oil
TECHNICAL SPECIFICATIONS GA 37-75 VSD+
Weight
Weight
Working pressure Capacity FAD* (min-max) Installed motor power Noise level** WorkPlace
Type WorkPlace
Full Feature

bar(e) psig l/s m³/hr cfm kW hp dB(A) kg kg


50/60 Hz version
4 58 26-132 94-475 55-280 37 50 67 860 1060
7 102 26-130 94-468 55-275 37 50 67 860 1060
GA 37 VSD +

9.5 138 25-115 90-414 53-244 37 50 67 860 1060


12,5 181 38-98 137-353 81-208 37 50 67 860 1060
4 58 26-157 94-565 55-333 45 60 67 860 1060
7 102 26-155 94-558 55-328 45 60 67 860 1060
GA 45 VSD+
9.5 138 25-136 90-490 53-288 45 60 67 860 1060
12.5 181 38-114 137-410 81-242 45 60 67 860 1060
4 58 26-189 94-680 55-400 55 75 67 900 1100
7 102 26-188 94-677 55-398 55 75 67 900 1100
GA 55 VSD +
9.5 138 26-166 94-598 55-352 55 75 67 900 1100
12.5 181 40-140 144-504 85-297 55 75 67 900 1100
4 58 26-226 94-814 55-479 75 100 70 920 1120
7 102 27-225 97-810 57-477 75 100 70 920 1120
GA 75 VSD+
9.5 138 27-198 97-713 57-420 75 100 70 920 1120
12.5 181 41-167 148-601 87-354 75 100 70 920 1120

* Unit performance measured according ISO 1217 ed. 4 2009, annex E, latest edition.
** Mean noise level measured at a distance of 1 m according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method); tolerance 3 dB(A).

Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20°C, 68°F.

FAD is measured at the following effective working pressures:


- 4 bar(e)
- 7 bar(e)
- 9.5 bar(e)
- 12.5 bar(e)
Maximum working pressure: 13 bar(e) (188 psig)

Options
Energy recovery
Pre-filter
Tropical thermostat
FoodGrade oil
UD+ filter
RXD oil
ES4i, ES6i
Transformer sales kit 200-230V / 500-575V
High ambient version
Power duct fan (standard on GA 75 VSD+, optional on GA 37-55 VSD+)

W
D

Standard Full Feature


DIMENSIONS
D (mm) W (mm) H (mm) D (in) W (in) H (in) D (mm) W (mm) H (mm) D (in) W (in) H (in)
GA 37-75 VSD+ 1100 1153 1968 43.31 45.39 77.48 1100 1656 1968 43.31 65.20 77.48
FLOW CHART GA 37-75 VSD+

1 Inlet filter 10 Solenoid valve


Wet compressed air
2 Sentinel valve 11 After cooler
3 Screw element 12 Fan Condensate
4 Interior permanent magnet motor (iPM) 13 Oil cooler
Dry compressed air
5 Air/oil vessel separator 14 Electronic drain (one drain mounted on after
6 Thermostatic bypass valve cooler for standard models, for Full Feature Intake air
7 Oil filter models a second drain is mounted on
the ID dryer) Air/oil mixture
8 Safety valve
9 Minimum pressure valve
15 Condensate prevention cycle
Oil
2935 0981 44 © 2017, Atlas Copco Airpower NV, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the
environment and the people around us. We make performance stand
the test of time. This is what we call – Sustainable Productivity.

www.atlascopco.com
Oil-injected
rotary screw compressors
GA 11+-30 (60 Hz)
(11-30 kW / 15-40 hp)

The industry-leading performer


Advanced connectivity and control, ground-
breaking efficiency, superior reliability, …
the GA 11+-30 meets and exceeds the highest
expectations. In addition, it comes with the widest
range of options so you can tailor the unit to your
specific requirements. If you need the very best,
the GA 11+-30 delivers without compromise.

FEATURES AND BENEFITS

Superior performance
State-of-the-art compression element coupled
with a maintenance-free gearbox.
100% continuous duty cycle.
Motor and drive train are greased for life to
avoid improper re-greasing.
Reduced electrical cubicle temperature doubles
electrical component lifetime.
Integrated dryer with heat exchanger and
integrated water separator for dry, quality air. State-of-the-art monitoring & control
Best-in-class low noise levels. High-tech Elektronikon® Touch controller with
high-definition color display, easy to use and
Supreme energy efficiency built to perform in the toughest conditions.
IE4 efficiency rated motor. Week timer, remote monitoring and
Free Air Delivery increased by 6-10%. maintenance scheduling.
Power consumption reduced by 3-8%. Built-in phase sequence relay for motor
control and protection.
Quick installation & maintenance Standard SMARTLINK remote monitoring to
Delivered plug & play. maximize air system performance and energy
Easy transportation. savings.
Main components are easily accessible. Optional multiple compressor control.
DIMENSIONS

159 cm

79 cm
126.7 cm

OPTIONS
Integrated filter Fan Saver Cycle Food-grade oil
Dryer bypass Compressor inlet pre-filter Roto-Xtend duty oil
Motor thermistors and Rain protection Energy recovery
anti-condensation heaters Lifting device Modulating control
Tropical thermostat Nema 4 & Nema 4X cubicle High ambient temperature versions
Freeze protection EQi central control license for 4 or 6 machines (55°C/131°F for pack, 50°C/122°F for FF)
Heavy duty air inlet filter (available on Elektronikon® Touch only) Dryer Save Cycle

TECHNICAL SPECIFICATIONS
Max. working pressure Weight
Installed Noise
Compressor Capacity FAD *
WorkPlace
WorkPlace Full motor power level** Work-
type WorkPlace Full
Feature Place
Feature
bar(e) psig bar(e) psig l/s m³/hr cfm kW hp dB(A) kg kg
GA 11+
100 7.4 107 7.2 104 39.4 141.8 83.5 11 15 68 411 451
125 9.1 132 8.9 128 34.3 123.5 72.7 11 15 68 411 451
150 10.8 157 10.6 153 30.4 109.4 64.4 11 15 68 411 451
175 12.6 183 12.3 179 26.1 94.0 55.3 11 15 68 411 451
GA 15+
100 7.4 107 7.2 104 51.9 186.8 110.0 15 20 69 427 483
125 9.1 132 8.9 128 46.1 166.0 97.7 15 20 69 427 483
150 10.8 157 10.6 153 40.5 145.8 85.8 15 20 69 427 467
175 12.6 183 12.3 179 36.0 129.6 76.3 15 20 69 427 467
GA 18+
100 7.4 107 7.2 104 63.6 229.0 134.8 18.5 25 69 428 484
125 9.1 132 8.9 128 56.6 203.8 119.9 18.5 25 69 428 484
150 10.8 157 10.6 153 51.2 184.3 108.5 18.5 25 69 428 484
175 12.6 183 12.3 179 45.3 163.1 96.0 18.5 25 69 428 484
GA 22+
100 7.4 107 7.2 104 73.8 265.7 156.4 22 30 67 487 545
125 9.1 132 8.9 128 69.2 249.1 146.6 22 30 67 487 545
150 10.8 157 10.6 153 63.0 226.8 133.5 22 30 67 487 545
175 12.6 183 12.3 179 58.1 209.2 123.1 22 30 67 487 545
GA 26+
100 7.4 107 7.2 104 85.3 307.1 180.7 26 35 68 490 548
125 9.1 132 8.9 128 80.6 290.2 170.8 26 35 68 490 548
150 10.8 157 10.6 153 72.7 261.7 154.0 26 35 68 490 545
175 12.6 183 12.3 179 66.1 238.0 140.1 26 35 68 490 545
GA 30
100 7.4 107 7.2 104 93.8 337.7 198.8 30 40 70 509 567
125 9.1 132 8.9 128 90.4 325.4 191.5 30 40 70 509 567
150 10.8 157 10.6 153 83.7 301.3 177.4 30 40 70 509 567
175 12.6 183 12.3 179 75.8 272.9 160.6 30 40 70 509 567
*
Unit performance measured according to ISO 1217, Annex C, latest edition.
**
Mean noise level measured according to ISO 2151/Pneuro/Cagi PN8NTC2 test code; tolerance 2 dB(A).
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi)
- Intake air temperature 20°C/68°F
FAD is measured at the following working pressures:
- 7.5 bar versions at 7 bar
- 8 bar versions at 8 bar
- 10 bar versions at 9.5 bar
- 13 bar versions at 12.5 bar
Pressure dewpoint of integrated refrigerant dryer of GA 11+ - GA 15+ - GA 18+ - GA 22+ - GA 26+ - GA 30
at reference conditions 2°C to 3°C/36°F to 37°F.

2935 0827 40 © 2018 - Atlas Copco Airpower NV, Belgium. All rights reserved.
Designs and specifications are subject to change without notice or obligation.
Read all safety instructions in the manual before usage.
Oil-injected
rotary screw compressors
GA 11+-30 (50 Hz)
(11-30 kW / 15-40 hp)

The industry-leading performer


Advanced connectivity and control, ground-
breaking efficiency, superior reliability, …
the GA 11+-30 meets and exceeds the highest
expectations. In addition, it comes with the widest
range of options so you can tailor the unit to your
specific requirements. If you need the very best,
the GA 11+-30 delivers without compromise.

FEATURES AND BENEFITS

Superior performance
State-of-the-art compression element coupled
with a maintenance-free gearbox.
100% continuous duty cycle.
Motor and drive train are greased for life to
avoid improper re-greasing.
Reduced electrical cubicle temperature doubles
electrical component lifetime.
Integrated dryer with heat exchanger and
integrated water separator for dry, quality air. State-of-the-art monitoring & control
Best-in-class low noise levels. High-tech Elektronikon® Touch controller with
high-definition color display, easy to use and
Supreme energy efficiency built to perform in the toughest conditions.
IE4 efficiency rated motor. Week timer, remote monitoring and
Free Air Delivery increased by 6-10%. maintenance scheduling.
Power consumption reduced by 3-8%. Built-in phase sequence relay for motor
control and protection.
Quick installation & maintenance Standard SMARTLINK remote monitoring to
Delivered plug & play. maximize air system performance and energy
Easy transportation. savings.
Main components are easily accessible. Optional multiple compressor control.
DIMENSIONS

159 cm

79 cm
126.7 cm

OPTIONS
Integrated filter Fan Saver Cycle Food-grade oil
Dryer bypass Compressor inlet pre-filter Roto-Xtend duty oil
Motor thermistors and Rain protection Energy recovery
anti-condensation heaters Lifting device Modulating control
Tropical thermostat Nema 4 & Nema 4X cubicle High ambient temperature versions
Freeze protection EQi central control license for 4 or 6 machines (55°C/131°F for pack, 50°C/122°F for FF)
Heavy duty air inlet filter (available on Elektronikon® Touch only) Dryer Save Cycle

TECHNICAL SPECIFICATIONS
Max. working pressure Weight
Installed Noise
Compressor Capacity FAD *
WorkPlace
WorkPlace Full motor power level** Work-
type WorkPlace Full
Feature Place
Feature
bar(e) psig bar(e) psig l/s m³/hr cfm kW hp dB(A) kg kg
GA 11+
7.5 7.5 109 7.3 105 37.2 133.9 78.8 11 15 68 411 451
8.5 8.5 116 8.3 120 35.7 128.5 75.6 11 15 68 411 451
10 10 145 9.8 141 32.3 116.3 68.4 11 15 68 411 451
13 13 189 12.8 185 26.7 96.1 56.6 11 15 68 411 451
GA 15+
7.5 7.5 109 7.3 105 51.7 186.1 109.5 15 20 69 427 483
8.5 8.5 116 8.3 120 46.1 166.0 97.7 15 20 69 427 483
10 10 145 9.8 141 41.1 148.0 87.1 15 20 69 427 467
13 13 189 12.8 185 36.9 132.8 78.2 15 20 69 427 467
GA 18+
7.5 7.5 109 7.3 105 62.6 225.4 132.6 18.5 25 69 428 484
8.5 8.5 116 8.3 120 58.2 209.5 123.3 18.5 25 69 428 484
10 10 145 9.8 141 51.3 184.7 108.7 18.5 25 69 428 484
13 13 189 12.8 185 45.8 164.9 97.0 18.5 25 69 428 484
GA 22+
7.5 7.5 109 7.3 105 72.6 261.4 153.8 22 30 67 487 545
8.5 8.5 116 8.3 120 69.7 250.9 147.7 22 30 67 487 545
10 10 145 9.8 141 62.6 225.4 132.6 22 30 67 487 545
13 13 189 12.8 185 55.1 198.4 116.8 22 30 67 487 545
GA 26+
7.5 7.5 109 7.3 105 87.2 313.9 184.8 26 35 68 490 548
8.5 8.5 116 8.3 120 83.7 301.3 177.4 26 35 68 490 548
10 10 145 9.8 141 76.5 275.4 162.1 26 35 68 490 545
13 13 189 12.8 185 66.2 238.3 140.3 26 35 68 490 545
GA 30
7.5 7.5 109 7.3 105 94.0 338.4 199.2 30 40 70 509 567
8.5 8.5 116 8.3 120 93.1 335.2 197.3 30 40 70 509 567
10 10 145 9.8 141 86.4 311.0 183.1 30 40 70 509 567
13 13 189 12.8 185 77.0 277.2 163.2 30 40 70 509 567
*
Unit performance measured according to ISO 1217, Annex C, latest edition.
**
Mean noise level measured according to ISO 2151/Pneuro/Cagi PN8NTC2 test code; tolerance 2 dB(A).
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi)
- Intake air temperature 20°C/68°F
FAD is measured at the following working pressures:
- 7.5 bar versions at 7 bar
- 8 bar versions at 8 bar
- 10 bar versions at 9.5 bar
- 13 bar versions at 12.5 bar
Pressure dewpoint of integrated refrigerant dryer of GA 11+ - GA 15+ - GA 18+ - GA 22+ - GA 26+ - GA 30
at reference conditions 2°C to 3°C/36°F to 37°F.

2935 0826 40 © 2018 - Atlas Copco Airpower NV, Belgium. All rights reserved.
Designs and specifications are subject to change without notice or obligation.
Read all safety instructions in the manual before usage.
Oil-injected rotary
screw compressors
GA 15-26
GA 11+-30
Meeting your
every need for
compressed air
Atlas Copco's GA oil-injected screw
compressors provide you with industry-leading
performance and reliability and allow you to
benefit from a low cost of ownership. The GA
15-26 stands for a high quality, reliable air
compressor with the lowest initial investment.
The GA 11+-30 delivers top performance in the
fixed speed compressor market.

2 - Atlas Copco GA 15-26 / GA 11+-30 compressors


GA 15-26 GA 11+-30
Compact economical compressors State-of-the-art performers
• Premium GA quality and optimal • Exceptional Free Air Delivery.
serviceability at the lowest initial • Best-in-class power consumption
investment. and noise emission.
• Good-quality, dry air thanks to the • Thanks to the integrated dryer,
integrated dryer. high quality dry air is guaranteed.
• Total control and assured efficiency • Easy monitoring and maintenance thanks
with the Elektronikon® controller. to the Elektronikon® graphic controller with
high-definition color display.

Atlas Copco GA 15-26 / GA 11+-30 compressors - 3


GA 15-26:
Compact economical compressors
Set to tackle your daily challenges, Atlas Copco’s high-performance GA compressors beat any
workshop solution. Ready to supply high-quality air, they keep your air network clean and your
production up and running.

1 Robust element & motor


• The GA 15-26’s compression element, the
most used in its size, is combined with an 4
IE3/NEMA Class 1 efficiency motor.
• A 2-3% higher efficiency with the gear- 3
driven drive train compared to belt-driven
systems.
• Gear-driven drive train for best-in-class
reliability and limited maintenance. 1

2 Advanced monitoring
• State-of-the-art monitoring using a simple
Ethernet connection, thanks to the Elektronikon®
with a built-in server.
• Service and warning indications, error detection
and compressor shut-down.
• Optional Elektronikon® graphic controller for
further enhanced remote monitoring features
and service time indications.

4 - Atlas Copco GA 15-26 / GA 11+-30 compressors


3 High-tech oil vessel
• Protection from oil contamination:
extremely low oil carry-over thanks to
the vertical design of the oil vessel.
• Extremely low losses of compressed air
during load/unload cycle thanks to
minimized oil vessel size.

4 Integrated quality air solutions


• The integrated dryer avoids condensation and
corrosion in the network. Optional filters for air quality
up to ISO Class 1 level (<0.01 ppm).
• Standard included water separator.
• Additional energy savings with the dryer’s no-loss
electronic drain.

5 Easy installation
• A true plug-and-play solution, ideal machine
for installation companies and OEMs.
• Optional integrated dryer.
• Easy transportation by forklift.
• Remarkably compact footprint.

Atlas Copco GA 15-26 / GA 11+-30 compressors - 5


GA 11+-30:
Industry-leading performers
Re-engineered to break records, the industrial GA 11+-30 compressors have the best air delivery capacity
in the industry. These all-in-one solutions provide high-quality air at the lowest possible operating
costs and offer extended monitoring possibilities.

1 Reliable motor & drive train


3
• The gearbox’s maintenance-free
transmission maximizes durability.
• The motor and drive train are greased
for life to avoid improper re-lubrication.
• Free Air Delivery is increased by 6-17%
2
and power consumption is reduced by
3-12% thanks to packaging and new
compressor element.

2 Electrical cubicle
• Reduced cubicle temperature doubles
the lifetime of the electrical components.
• Avoid damage with the electrical
cubicle’s standard phase sequence relay.

6 - Atlas Copco GA 15-26 / GA 11+-30 compressors


3 Advanced control
• High-tech Elektronikon® graphic controller
with warning indications, compressor
shut-down and maintenance scheduling.
• Optional centralized control over up to
6 compressors via Elektronikon®.

4 Quality air solutions


• Integrated dryer range with counterflow
heat exchanger, integrated water separator
and optional Dryer Saver Cycle.
• The integrated dryer can be outfitted with
optional UD+ filter, resulting in oil carry-
1 over as low as 0.01 ppm.
• Water separation of nearly 100% in all
conditions with the standard electronic
no-loss drain and integrated water
separator in the aftercooler.

5 Energy-saving features
• Optional energy recovery system.
• Optional fan Saver Cycle, reducing
energy consumption.

Atlas Copco GA 15-26 / GA 11+-30 compressors - 7


A step ahead in
monitoring and controls
The next-generation Elektronikon® operating system offers a great variety of control and monitoring
features that allow you to increase your compressor’s efficiency and reliability. To maximize energy
efficiency, the Elektronikon® controls the main drive motor and regulates system pressure within a
predefined and narrow pressure band.

GA 15-26: Elektronikon® controller GA 11+-30:


Advanced Elektronikon® graphic controller
• Improved ease of use: intuitive navigation
system with clear pictograms and extra 4th LED • Improved user-friendliness: 3.5-inch
indicator for service. high-definition color display with clear pictograms
• Visualization through web browser using a and extra 4th LED indicator for service.
simple Ethernet connection. • Internet-based compressor visualization using
• Easy to upgrade. a simple Ethernet connection.

• Increased reliability: more durable keyboard. • Increased reliability: new, user-friendly,


multilingual user interface and durable keyboard.

Key features:
Key features:
• Automatic restart after voltage failure.
• Automatic restart after voltage failure.
• Delayed Second Stop function.
• Dual pressure set point.
• Option to upgrade to the advanced
Elektronikon® graphic controller. • More flexibility: four different week-schedules
that can be programmed for a period of
10 consecutive weeks.
• On-screen Delayed Second Stop function.
• Graphical indication service plan.
• Remote control and connectivity functions.

8 - Atlas Copco GA 15-26 / GA 11+-30 compressors


Optional integrated compressor controller
Install, with a simple license, the optional integrated compressor
controller and get simple, central control to reduce system pressure
and energy consumption in installations of up to 4 (ES4i) or 6 (ES6i)
compressors.

Dual pressure set point


& delayed second stop
Most production processes create fluctuating levels of
demand which, in turn, can create energy waste in low use
periods. Using either the standard or graphic Elektronikon®
controller, you can manually or automatically create two different
system pressure bands to optimize energy use and reduce costs at low
use times. In addition, the sophisticated Delayed Second Stop (DSS) runs
the drive motor only when needed. As the desired system pressure is
maintained while the drive motor’s run time is minimized, energy
consumption is kept at a minimum.

Without DSS With DSS


Power Power

Loaded
Loaded Unloaded

Unloaded Stopped

Time Time
Saved energy

Recover and save energy


As much as 90% of the electrical energy used by a compressed air solution is converted into heat. Using
Atlas Copco’s integrated energy recovery systems, it is feasible to recover up to ≈ 75% of that power input
as hot air or hot water without any adverse influence on the compressor’s performance. Through efficient
usage of the recovered energy, you bring about important energy cost savings and obtain a high return on
investment.

Applications
• Auxiliary or main heating of warehouses,
workshops…
• Industrial process heating
• Water heating for laundries, industrial cleaning
and sanitary facilities
• Canteens and large kitchens
• Food industry
• Chemical and pharmaceutical industries
• Drying processes

Atlas Copco GA 15-26 / GA 11+-30 compressors - 9


Excellence in quality air
Untreated compressed air contains moisture, aerosols and dirt particles that can damage your
air system and contaminate your end product. The resulting maintenance costs can far exceed air
treatment costs. GA compressors provide the clean, dry air that improves your system’s reliability,
avoiding costly downtime and production delays, and safeguarding the quality of your products.

Integrated purity
Many Atlas Copco compressors (Full Feature option)
come with an integrated dryer that efficiently
removes moisture, aerosols and dirt particles to
protect your investment. This quality air expands the
life of equipment, increasing efficiency and ensuring
quality in your final product.

Main benefits of the new,


integrated dryer solutions
• Thanks to the Saver Cycle, based on an extra
ambient sensor, the dryer will shut down when
a normal dew point is reached, meaning that
2/3 of the dryer’s power can be recuperated
(optional for GA+).
• Available in several variants, allowing you to
gain high-quality air in all ambient conditions.
• Pressure dew point at 3°C/37°F on GA and GA+
(100% relative humidity at 20°C/68°F, 5°C/41°F
on GA).
• The dryer’s global warming potential has been
reduced by 44%. This not only results from the
refrigerant type R134a’s environmentally-
friendly characteristics, but also from the
smaller volume that is needed (valid for both
GA and GA+).
• Can be outfitted with optional UD+ filter,
allowing you to obtain the exact air quality you
need for your specific application.

Water pressure Water pressure


ISO quality class* Dirt particle size Oil concentration
dew point GA ** dew point GA+ **

Pack unit 3.-.4 3 microns - - 3 ppm

Full Feature unit 3.4.4 3 microns +5°C/41°F +3ºC/37°F 3 ppm

Full Feature unit with Class 2 integrated filter 2.4.2 1 micron +5°C/41°F +3ºC/37°F 0.1 ppm

Full Feature unit with Class 1 integrated filter 1.4.1 0.01 microns +3°C/37°F +3ºC/37°F 0.01 ppm

*
The table values are maximum limits according to the respective ISO quality class.
**
Water pressure dew point based on 100% RH at 20°C/68°F.

10 - Atlas Copco GA 15-26 / GA 11+-30 compressors


Tailored
to your needs
Some applications may need or may benefit from
additional options and more refined control and air
treatment systems. To meet these needs, Atlas Copco
has developed options and easily integrated compatible
equipment providing the lowest cost compressed air.

GA 15-26 GA 11+-30

Integrated filter Class 2 • •

Integrated filter Class 1 • •

Tropical thermostat • •
High ambient temperature versions (55°C/131°F for
pack, 50°C/122°F for FF)
• •

Roto-Xtend duty oil • •

Elektronikon graphic controller


® *

Wooden package • •

Heavy duty filter - •

Food-grade oil • •

Integrated oil/water separator OSD - •

Condensate water separator and auto drain •

Modulating control • •

Compressor inlet pre-filter - •

Energy recovery - •

Rain protection - •

Motor space heater + thermistors - •


Central control license 4 (ES4i) or 6 (ES6i)
machines (on graphic)
• •

*
Optional for GA 30. : Standard • : Optional - : Not available

Atlas Copco GA 15-26 / GA 11+-30 compressors - 11


Technical specifications
GA 15-26
50 Hz version
Weight
Max. Installed Noise
Capacity FAD*
Compressor Pressure working pressure motor power level**
type variant Pack Floor FF Tank

bar(e) psi l/s m³/min cfm kW hp dB(A) kg lbs kg lbs

GA 15 7.5 7.5 109 45.8 2.75 97.1 15 20 65 421 928 474 1045

8.5 8.5 123 42.0 2.52 88.9 15 20 65 421 928 474 1045

10.5 10.5 152 38.8 2.33 82.2 15 20 65 421 928 472 1041

13 13.0 189 32.6 1.95 69.0 15 20 65 421 928 470 1036

GA 18 7.5 7.5 109 56.5 3.39 119.6 18.5 25 67 431 950 495 1091

8.5 8.5 123 53.8 3.23 114.0 18.5 25 67 431 950 495 1091

10.5 10.5 152 49.0 2.94 103.8 18.5 25 67 431 950 493 1087

13 13.0 189 40.7 2.44 86.2 18.5 25 67 431 950 491 1082

GA 22 7.5 7.5 109 65.1 3.91 138.0 22 30 68 440 970 495 1091

8.5 8.5 123 63.5 3.81 134.6 22 30 68 440 970 495 1091

10.5 10.5 152 53.3 3.20 112.9 22 30 68 440 970 493 1087

13 13.0 189 49.0 2.94 103.8 22 30 68 440 970 491 1082

GA 26 7.5 7.5 109 72.9 4.37 154.4 30 40 69 500 1102 558 1230

8.5 8.5 123 68.1 4.09 144.2 30 40 69 500 1102 558 1230

10.5 10.5 152 61.5 3.69 130.3 30 40 69 500 1102 556 1226

13 13.0 189 54.7 3.28 115.9 30 40 69 500 1102 554 1221

Dimensions
L: 1225 mm/49”
W: 695 mm/27”
H: 1475 mm/58”

L W

12 - Atlas Copco GA 15-26 / GA 11+-30 compressors


60 Hz version
Weight
Max. Installed Noise
Capacity FAD*
Compressor Pressure working pressure motor power level**
type variant Pack Floor FF Tank

bar(e) psi l/s m³/min cfm kW hp dB(A) kg lbs kg lbs

GA 15 100 7.4 107 47.1 2.83 99.8 7.5 10 66 421 928 474 1045

125 9.1 132 42.4 2.54 89.8 7.5 10 66 421 928 474 1045

150 10.8 157 39.2 2.35 83.0 7.5 10 66 421 928 472 1041

175 12.5 181 30.3 1.82 64.2 7.5 10 66 421 928 470 1036

GA 18 100 7.4 107 56.9 3.41 120.5 11 15 68 431 950 495 1091

125 9.1 132 50.9 3.05 107.8 11 15 68 431 950 495 1091

150 10.8 157 48.0 2.88 101.7 11 15 68 431 950 493 1087

175 12.5 181 42.2 2.53 89.4 11 15 68 431 950 491 1082

GA 22 100 7.4 107 67.7 4.06 143.3 15 20 69 440 970 495 1091

125 9.1 132 60.6 3.64 128.4 15 20 69 440 970 495 1091

150 10.8 157 54.4 3.26 115.2 15 20 69 440 970 493 1087

175 12.5 181 49.0 2.94 103.8 15 20 69 440 970 491 1082

GA 26 100 7.4 107 74.4 4.46 157.6 18.5 25 70 500 1102 558 1230

125 9.1 132 69.5 4.17 147.2 18.5 25 70 500 1102 558 1230

150 10.8 157 62.8 3.77 133.0 18.5 25 70 500 1102 556 1226

175 12.5 181 57.1 3.43 120.9 18.5 25 70 500 1102 554 1221

*
Unit performance measured according to ISO 1217 ed. 4 2009, annex E, latest edition.
**
Mean noise level measured at a distance of 1 m according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method); tolerance 3 dB(A).

Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20°C/68°F.

FAD is measured at the following effective working pressures:


- 7 bar(e)
- 8 bar(e)
- 10 bar(e)
- 12.5 bar(e)

Maximum working pressure:


- 13 bar(e) (188 psig) Intake air

Air/oil mixture

Oil

Wet compressed air

Condensate

Dry air

Gaseous coolant

Liquid coolant

Compressed air without free water

Dry compressed air

Water

Refrigerant gas/liquid mixture

High pressure, hot refrigerant gas

Low pressure, cool refrigerant gas

High pressure refrigerant liquid

Low pressure refrigerant liquid

Atlas Copco GA 15-26 / GA 11+-30 compressors - 13


Technical specifications
GA 11+-30
50 Hz version
Max.
Weight
working pressure
Installed Noise
Capacity FAD*
Compressor Pressure motor power level**
WorkPlace WorkPlace
type variant WorkPlace WorkPlace
Full Feature Full Feature

bar(e) psi bar(e) psi l/s m³/min cfm kW hp dB(A) kg lbs kg lbs

GA 11+ 7.5 7.5 109 7.3 105 35.8 128.9 75.9 11 15 63 410 904 455 1003
8.5 8.5 116 8.3 120 33.8 121.7 71.7 11 15 63 410 904 455 1003
10 10 145 9.8 141 30.3 109.1 64.2 11 15 63 410 904 455 1003
13 13 189 12.8 185 25.2 90.7 53.4 11 15 63 410 904 455 1003
GA 15 + 7.5 7.5 109 7.3 105 46.9 168.8 99.4 15 20 64 420 926 470 1036
8.5 8.5 116 8.3 120 43.8 157.7 92.9 15 20 64 420 926 470 1036
10 10 145 9.8 141 39.8 143.3 84.4 15 20 64 420 926 470 1036
13 13 189 12.8 185 32.8 118.1 69.5 15 20 64 420 926 470 1036
GA 18 + 7.5 7.5 109 7.3 105 58.1 209.2 123.2 18.5 25 65 440 970 500 1102
8.5 8.5 116 8.3 120 54.3 195.5 115.1 18.5 25 65 440 970 500 1102
10 10 145 9.8 141 48.7 175.3 103.2 18.5 25 65 440 970 500 1102
13 13 189 12.8 185 41.1 148.0 87.1 18.5 25 65 440 970 500 1102
GA 22+ 7.5 7.5 109 7.3 105 68.2 245.5 144.6 22 30 66 455 1003 515 1135
8.5 8.5 116 8.3 120 64.5 232.2 136.7 22 30 66 455 1003 515 1135
10 10 145 9.8 141 58.1 209.2 123.2 22 30 66 455 1003 515 1135
13 13 189 12.8 185 50.7 182.5 107.5 22 30 66 455 1003 515 1135
GA 26 + 7.5 7.5 109 7.3 105 79.8 287.3 169.2 26 35 67 525 1157 595 1312
8.5 8.5 116 8.3 120 76.2 274.3 161.5 26 35 67 525 1157 595 1312
10 10 145 9.8 141 69.3 249.5 146.9 26 35 67 525 1157 595 1312
13 13 189 12.8 185 60.1 216.4 127.4 26 35 67 525 1157 595 1312
GA 30 7.5 7.5 109 7.3 105 90.0 324.0 190.8 30 40 68 540 1191 610 1345
8.5 8.5 116 8.3 120 86.4 311.0 183.2 30 40 68 540 1191 610 1345
10 10 145 9.8 141 79.8 287.3 169.2 30 40 68 540 1191 610 1345
13 13 189 12.8 185 68.7 247.3 145.6 30 40 68 540 1191 610 1345

Standard Full Feature version (FF)

10
20
16
8 8

2 7 9 22
14 9

3
1 21 17
19
13
15
5
11 18
12

Air flow Oil flow Refrigerant flow


1 Air intake filter 11 Oil 16 Refrigerant compressor
2 Air intake valve 12 Oil-cooler 17 Condenser
3 Compression element 13 Hermostatic bypass valve 18 Liquid refrigerant dryer/filter
4 Non return valve 14 Oil filter 19 Thermostatic expansion valve
5 Air/oil separator vessel 15 Oil stop valve 20 Evaporator
6 Minimum pressure valve 21 Hot gas bypass valve
7 After-cooler 22 Accumulator
8 Air-air heat exchanger
9 Water separator with drain
10 DD/PD filters (optional)

14 - Atlas Copco GA 15-26 / GA 11+-30 compressors


60 Hz version
Max.
Weight
working pressure
Installed Noise
Capacity FAD*
Compressor Pressure motor power level**
WorkPlace WorkPlace
type variant WorkPlace WorkPlace
Full Feature Full Feature

bar(e) psi bar(e) psi l/s m³/min cfm kW hp dB(A) kg lbs kg lbs

GA 11+ 100 7.4 107 7.2 104 37.0 133.2 78.4 11 15 63 410 904 455 1003
125 9.1 132 8.9 128 32.0 115.2 67.8 11 15 63 410 904 455 1003
150 10.8 157 10.3 149 29.3 105.5 62.1 11 15 63 410 904 455 1003
175 12.5 181 12.3 178 25.3 91.1 53.6 11 15 63 410 904 455 1003
GA 15 + 100 7.4 107 7.2 104 48.3 173.9 102.4 15 20 64 420 926 470 1036
125 9.1 132 8.9 128 42.9 154.4 90.9 15 20 64 420 926 470 1036
150 10.8 157 10.3 149 39.4 141.8 83.5 15 20 64 420 926 470 1036
175 12.5 181 12.3 178 33.9 122.0 71.9 15 20 64 420 926 470 1036
GA 18 + 100 7.4 107 7.2 104 59.6 214.6 126.4 18.5 25 66 440 970 500 1102
125 9.1 132 8.9 128 53.3 191.9 113.0 18.5 25 66 440 970 500 1102
150 10.8 157 10.3 149 47.8 172.1 101.3 18.5 25 66 440 970 500 1102
175 12.5 181 12.3 178 42.5 153.0 90.1 18.5 25 66 440 970 500 1102
GA 22+ 100 7.4 107 7.2 104 70.3 253.1 149.0 22 30 67 455 1003 515 1135
125 9.1 132 8.9 128 62.9 226.4 133.3 22 30 67 455 1003 515 1135
150 10.8 157 10.3 149 56.9 204.8 120.6 22 30 67 455 1003 515 1135
175 12.5 181 12.3 178 52.3 188.3 110.9 22 30 67 455 1003 515 1135
GA 26 + 100 7.4 107 7.2 104 81.2 292.3 172.1 26 35 67 525 1157 595 1312
125 9.1 132 8.9 128 74.1 266.8 157.1 26 35 67 525 1157 595 1312
150 10.8 157 10.3 149 67.4 242.6 142.9 26 35 67 525 1157 595 1312
175 12.5 181 12.3 178 60.7 218.5 128.7 26 35 67 525 1157 595 1312
GA 30 100 7.4 107 7.2 104 90.1 324.4 191.0 30 40 68 540 1191 610 1345
125 9.1 132 8.9 128 84.1 302.8 178.3 30 40 68 540 1191 610 1345
150 10.8 157 10.3 149 77.1 277.6 163.5 30 40 68 540 1191 610 1345
175 12.5 181 12.3 178 70.1 252.4 148.6 30 40 68 540 1191 610 1345

*
Unit performance measured according to ISO 1217, Annex C, latest edition.
**
Mean noise level measured according to ISO 2151/Pneuro/Cagi PN8NTC2 test code; tolerance 2 dB(A).

Reference conditions:
• Absolute inlet pressure 1 bar (14.5 psi)
• Intake air temperature 20°C/68°F

FAD is measured at the following working pressures:


• 7.5 bar versions at 7 bar
• 8 bar versions at 8 bar
• 10 bar versions at 9.5 bar
• 13 bar versions at 12.5 bar

Pressure dew point of integrated refrigerant dryer of GA 11+ - GA 15+ - GA 18+ - GA 22+ - GA 26+ - GA 30 at
reference conditions 2°C to 3°C/36°F to 37°F.

Dimensions
H
H: 1475 mm/58”
GA 11+ - GA 22+ L: 1255 mm/49”
W: 692 mm/27”

H: 1475 mm/58”
GA 26+ - GA 30 L: 1255 mm/49”
W: 865 mm/34”
W
L

Atlas Copco GA 15-26 / GA 11+-30 compressors - 15


2935 0849 46 © 2014, Atlas Copco Airpower NV, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

Committed to sustainable productivity


We stand by our responsibilities towards our customers, towards the environment and the people around us.
We make performance stand the test of time. This is what we call – Sustainable Productivity.

2935 0812 42 © 2017, Atlas Copco Airpower NV, Belgium. All rights reserved.
Designs and specifications are subject to change without notice or obligation.
Read all safety instructions in the manual before usage.
OIL-INJECTED ROTARY SCREW
COMPRESSORS
GA 30+-90/GA 37-90 VSD
(30-90 kW/40-125 hp)
GA VSD: ULTIMATE ENERGY SAVER
The ultimate smart solution, driven by efficiency  Unique integrated Variable Speed Drive (VSD) technology for on average 35%
energy savings.

Atlas Copco’s GA 30+-90 compressors bring you outstanding sustainability, reliability and performance, while minimizing the total cost of  Industry-leading operating turndown range and flexible pressure selection: 4-13 bar.
 Start under system pressure due to special VSD motor, no idling time.
ownership. A choice of three premium compressor types (GA VSD, GA+ and GA) provides you with the compressed air solution that perfectly
 Integrated Dryer Saver Cycle saves up to 60% of the dryer’s electrical consumption.
matches your requirements with clear value propositions. Built to perform even in the harshest environments, these compressors keep your  Smart Elektronikon® graphic compressor controller with high-definition color display
working to a set point minimizes pressure drops.
production running efficiently.

NEW HEIGHTS IN SUSTAINABILITY


GA+: INDUSTRY-LEADING PERFORMANCE
FICIENCY
The GA 30+-90 family enables you to realize sustainable productivity
through lower lifecycle costs and maximum uptime. IE2 Premium
IE2 HIGH EF
Efficiency motors in combination with the highly efficient element Industry-leading Free Air Delivery and low energy consumption.

minimize operating cost. The integrated dryer R410A reduces ozone IE2 High Efficiency motor in combination with efficient element.

depletion and protects the environment. Maximum uptime is


Low noise emission suitable for workplace installation.

achieved by maintenance from one side and complete drive


Environmentally-friendly R410A integrated dryer reduces footprint and

train accessibility.
pressure drops.
Smart Elektronikon® graphic compressor controller with high-definition

color display.

NEW MILESTONES IN RELIABILITY GA: PREMIUM COMPRESSOR


The reliability of the GA 30 -90 range starts with the cool
+
High performance Free Air Delivery.

canopy and low element outlet temperatures, an oversized


BENCHMARKING PERFORMANCE separate oil cooler and an aftercooler with patented integrated
IE2 High Efficiency motor in combination with highly efficient element.

Outstanding performance is ensured by design, with IE2 motors mechanical separator. The three-stage air/oil separation Premium quality at the lowest initial investment.

in combination with Atlas Copco’s highly efficient element and an ensures low oil consumption. All electrical cubicles are in Efficient environmentally-friendly R410A integrated dryer reduces

oversized cooling arrangement resulting in significant energy overpressure, preventing electrically conductive dust, thus footprint and pressure drops.
savings. Internal pressure drops from inlet to discharge are increasing the lifetime of electrical components. Ensured efficiency of Elektronikon® controller with connectivity.

optimized. Efficient smart compressor controls and Atlas Copco


algorithms minimize the working pressure band, saving energy.
VSD: Driving down your energy costs HOW GA VSD TECHNOLOGY SAVES ENERGY
Over 80% of a compressor’s lifecycle cost is taken up by the energy it consumes. Moreover, the generation of compressed Contact your local Atlas Copco representative for an audit of your compressed air system. A real-time measurement
simulation and audit report can be provided with recommendations for additional savings and sizing to meet your
air can account for more than 40% of a plant’s total electricity bill. To cut your energy costs, Atlas Copco pioneered compressed air needs.

Variable Speed Drive (VSD) technology in the compressed air industry. VSD leads to major energy savings, while protecting
AMPS STATUS OF GENERAL LOAD - NO LOAD COMPRESSOR
the environment for future generations. Thanks to continual investments in this technology, Atlas Copco offers the widest
55.00
range of integrated VSD compressors on the market. 50.00
45.00
40.00
35.00

WHY ATLAS COPCO VARIABLE SPEED DRIVE TECHNOLOGY? 30.00


25.00
 On average 35% energy savings during fluctuations in production demand with an extensive turndown range. 20.00

 Integrated Elektronikon® Graphic controller controls the motor speed and high efficiency frequency inverter. 15.00
10.00
 No wasted idling times or blow-off losses in normal operation.
5.00 Unload and blow-off losses
 Compressor can start/stop under full system pressure without the need to unload with special VSD motor.
Time
 Eliminates peak current penalty during start-up.
 Minimizes system leakage due to a lower system pressure.
EMC Compliance to directives (2004/108/EG).
IME WHAT IS UNIQUE ABOUT THE INTEGRATED ATLAS COPCO GA VSD?
NO IDLINGT

Air demand Energy consumption Air demand Energy consumption


1 The Elektronikon® controls both the compressor 6 Mechanical enhancements ensure that all com-
and the integrated converter, ensuring maximum ponents operate below critical vibration levels
machine safety within parameters. throughout the entire compressor speed range.

2 Flexible pressure selection from 4 to 13 bar with 7 A highly efficient frequency converter in a cool
electronic gearing reduces electricity costs. overpressure cubicle ensures stable operation in high
ambient temperatures up to 50°C/122°F*.
3 Special electric motor specifically designed for * Standard up to 46°C/114.8°F.
VSD operation (inverter duty motor). Bearings are
protected against induced bearing currents. Both motor 8 No ‘speed windows’ that can jeopardize the
and converter are perfectly tuned for highest efficiency energy savings and the stable net pressure. Turndown
Air demand Energy consumption Time Air demand GA VSD energy consumption Time
across the entire speed range. capability of the compressor is maximized to 80-85%.
Fixed speed load/unload

4 Electric motor specifically designed for low 9 The cubicle cooling booster increases the lifetime
In almost every production environment, air demand fluctuates depending on different factors such as the time of operating speeds with clear attention to motor cooling of electrical components due to a cool cubicle in
the day, week or even month. Extensive measurements and studies of compressed air demand profiles show that and compressor cooling requirements. overpressure and reduced dust ingress.
many compressors have substantial variations in air demand.
5 All Atlas Copco GA VSD compressors are EMC tested 10 Net pressure band is maintained within 0.10 bar,
and certified. External sources do not influence compressor 1.5 psi.
operation, nor does the compressor affect the operation of
other instruments via emissions or via the power supply line.
ON AVERAGE 35% ENERGY SAVINGS
Atlas Copco’s GA VSD technology closely follows the air demand by Operating range Non-integrated Atlas Copco Combined motor/converter efficiency
automatically adjusting the motor speed. This results in on average solution integrated solution
35% energy savings. The lifecycle cost of a compressor can be cut by 100%
an average of 22%. In addition, lowered system pressure with GA
VSD dramatically minimizes energy use across your production.

TOTAL COMPRESSOR LIFECYCLE COST


Energy Investment

Energy savings with VSD Maintenance


minimum maximum minimum maximum
Flow Motor speed

Speed windows Non-integrated VSD Integrated VSD


11
High reliability and smart energy Cubicle cooling booster
Cubicle in overpressure minimizes ingress of conductive dust.

Electrical components remain cool, enhancing lifetime of components.


1
Maintenance-free drive system
100% maintenance-free; totally enclosed and protected against dirt and dust.

10
Suitable for harsh environments.
 Integrated highly efficient
High-efficiency drive arrangement; no coupling or slippage losses.
 R410A dryer
Standard up to 46˚C/115˚F and for high ambient version 55˚C/131˚F.
 Excellence in air quality.

50% reduction in energy consumption compared


to traditional dryers.
Zero ozone depletion.

Incorporates optional DD and PD filters according


2 

to Class 1.4.1.
9
IE2 High Efficiency electrical motors
8
IP55, insulation Class F, B rise.

9
Non-drive side bearing greased for life.

Designed for continuous operation in harsh environments.



5 Elektronikon® for remote monitoring
Integrated smart algorithms reduce system pressure

and energy consumption.


Monitoring features include warning indications,

maintenance scheduling and online


3 visualization of machine’s condition.

Robust spin-on oil filter


High-efficiency, removing 300% smaller particles

4 8
than a conventional filter.
Integrated bypass valve with the oil filter.

7 Heavy-duty air intake filter
Protects the compressor components by removing

99.9% of dirt particles down to 3 microns.


3 Differential inlet pressure for proactive maintenance

while minimizing pressure drop.


2
4
SIL Smart inlet lock system for 1
GA VSD compressors
Superior designed vacuum and air pressure controlled

valve with minimal pressure drop and no springs.


Smart stop/start which eliminates back-pressure oil vapor.

7
Electronic no-loss water drain
5 (optional)
Ensures constant removal of condensate.
Separate oversized oil cooler

6
Manual integrated bypass for effective condensate
and aftercooler 

Low element outlet temperatures, ensuring long oil lifetime.



Water separator device (WSD) removal in case of power failure.

High efficient.
 Integrated with compressor’s Elektronikon® with

Removal of nearly 100% condensate by mechanical separator.



warning/alarm features.
Ensures constant removal of condensate.

No consumables.

No loss of compressed air.

Eliminates possibility of thermal shocks in coolers.



A step ahead in monitoring and controls Optional integrated compressor controller
The next-generation Elektronikon® operating system offers a wide variety of control and monitoring features that allow you to increase Install, with a simple license, the optional integrated compressor controller and get simple, central control to reduce system pressure and

your compressor’s efficiency and reliability. To maximize energy efficiency, the Elektronikon® controls the main drive motor and regulates energy consumption in installations of up to 4 (ES4i) or 6 (ES6i) compressors.

system pressure within a predefined and narrow pressure band.

Net Pressure WITHOUT CONTROL WITH CONTROL

1
2
Average Pressure
3 1 2 3 Average Pressure
Min. System Pressure Min. System Pressure

Compressors

The Elektronikon® continuously monitors critical parameters. Monitoring features include service and warning indications, error detection, compressor shut-down and
maintenance scheduling.

IMPROVED USER-FRIENDLINESS
3.5-inch high-definition color display with clear pictograms
 On-screen Delayed Second Stop function and VSD

DUAL PRESSURE SET POINT & DELAYED SECOND STOP
and extra 4th LED indicator for service. savings indication.
Most production processes create fluctuating levels of demand use times. In addition, the sophisticated Delayed Second Stop
Graphical display of key parameters (day, week, month) and
 Graphical indication Serviceplan, remote control and

which, in turn, can create energy waste in low use periods. (DSS) runs the drive motor only when needed. As the desired
32 language settings. connectivity functions.
Using either the standard or graphic Elektronikon® controller, you system pressure is maintained while the drive motor’s run time is
Internet-based compressor visualization using a simple
 Software upgrade available to control up to 6 compressors

can manually or automatically create two different system minimized, energy consumption is kept at a minimum.
Ethernet connection. by installing the optional integrated compressor controller.
pressure bands to optimize energy use and reduce costs at low

Without DSS With DSS

Power Power

Loaded Loaded
Unloaded Unloaded
ONLINE & MOBILE MONITORING Stopped
Time Time
Monitor your compressors over the Ethernet with the new
Saved energy
Elektronikon® controller. Monitoring features include warning
indications, compressor shut-down and maintenance scheduling.
The Atlas Copco App is available for iPhone/Android phones as
INTEGRATED DRYER SAVER CYCLE
well as iPad and Android tablets. It allows fingertip monitoring
of your compressed air system through your own secured network. Saver Cycle technology reduces the energy consumption of dew point suppression, the Elektronikon® starts and stops the
the integrated refrigerant dryers with the fan in light load dryer and the fan, minimizing energy use and protecting the air
applications. Using an ambient sensor to monitor the required system from corrosion.
Excellence in integrated air quality WorkPlace: Compressed air at the point of use
Untreated compressed air contains moisture, aerosols and dirt particles that can damage your air system and contaminate your end product, With the industry-leading low noise operation and integration of air and condensate treatment equipment, the GA+ offers complete versatility

resulting in risk of corrosion and compressed air system leaks. Maintenance costs can far exceed air treatment costs. Our compressors provide the for your production. The compressor’s integrated design allows it to be placed on the production floor, creating substantial energy savings for

clean, dry air that improves your system’s reliability, avoids costly downtime and production delays, and safeguards the quality of your products. your business.

SAVE MONEY AND THE ENVIRONMENT LOW INSTALLATION COSTS


Avoid risk of corrosion and system leaks, and ensure the effective safe disposal of untreated condensate – all within ISO 14001 standards. The GA+ can operate close to the point of use – eliminating the need for a dedicated compressor room.

The GA+ is delivered ready for use – minimizing production downtime and reducing installation costs.

Filtration equipment is integrated – reducing the need for costly external piping and minimizing pressure drops.

Low noise enables the above to be a reality.


E
ZERO OZON N
DEPLETIO
ON AVERAGE 50% ENERGY SAVINGS WITH
R410A INTEGRATED DRYERS
 Use of energy-efficient refrigerant R410A reduces operating costs.
  410A refrigerant reduces global warming potential by an average
R
of 50%.
 Environmentally-friendly characteristics; zero ozone depletion.
 Unique Saver Cycle Control, with ambient temperature sensor and
based on dryer load and relative humidity of compressed air, saves
energy at partial load.
 Heat exchanger cross-flow technology with low pressure drop.
 Zero waste of compressed air thanks to no-loss condensate drain.
 Pressure dew point of 3°C (100% relative humidity at 20°C).

INTEGRATED PURITY
The optional DD/PD filters and integrated refrigerant air dryer downstream equipment, increasing efficiency and ensuring REDUCED ENERGY AND MAINTENANCE COSTS
(IFD) efficiently remove moisture, aerosols and dirt particles to quality of your final product.
With less external piping, the GA+ minimizes pressure drop across the system which can reduce energy costs.

protect your investment. This air quality prolongs the life of
The filtration system produces clean air to prevent network corrosion – minimizing energy, repair and maintenance costs.

The GA+ operates at the lowest possible system pressure to reduce energy costs thanks to the Elektronikon® advanced

monitoring system.

ISO QUALITY CLASS* DIRT PARTICLE SIZE WATER PRESSURE DEW POINT** OIL CONCENTRATION

3.-.4 3 microns - 3 ppm

3.4.4 3 microns +3ºC, 37ºF 3 ppm INTEGRATED CONDENSATE MANAGEMENT


2.4.2 1 micron +3ºC, 37ºF 0.1 ppm OSCi is an efficient integrated solution that removes oil from condensate.

1.4.1 0.01 microns +3ºC, 37ºF 0.01 ppm Oil carryover contained in condensate can harm the environment.

* The table values reflect the maximum limits according to the temperature ISO gravity class.
Treated condensate protects water, wildlife and ecosystems.

** Water pressure dew point based on 100% RH at 20°C/68°F.


The delivered water is harmless and can be disposed in a sewage system,

reducing disposal costs.


Optimize your system Flow charts
Some applications may need or may benefit from additional options and more refined control/air treatment systems. To meet these needs, VARIABLE SPEED DRIVE: GA VSD

Atlas Copco has developed options and easily integrated compatible equipment.
F

GA 30+-90 GA 37-90 VSD

Integrated filter kit class 1*


E
Integrated filter kit class 2* A Intake air
Air treatment Dryer bypass* B Air/oil mixture
C Oil
Condensate OSCi
A D Wet compressed air
Motor space heater - E Condensate
Motor space heater + thermistors - F Dried compressed air
Water shut-off valve** D
Phase sequence relay (export) - B
Tropical thermostat - E

Freeze protection
Pre-filter
Advanced monitoring C
Vp
Protection Electronic water drain (EWD)

Rain protection -
Public works Main power isolator switch
A Intake air D Wet compressed air
ES 100 relays***
AIRconnect FIXED
B SPEED: GA + & GAE
Air/oil mixture Condensate
Elektronikon® Graphic upgrade (only for GA 37 to GA 75) - C Oil F Dried compressed air
ES4i/ES6i (for Elektronikon® Graphic)
Communication F
Digital I/O expansion module

Food grade oil


Oils Roto – Xtend duty oil (8000 hours)

Witness performance test


Energy recovery E

Modulating control - A Intake air


High-ambient temperature version (HAV 55°C, 131°F)**** B Air/oil mixture
General options IT/TT ancillaries - C Oil
D Wet compressed air
*FF units only. ** Water-cooled units. *** Includes potential-free contacts: motor running, compressor load/unload. **** FF units max 50°C, 122°F.
E Condensate
F Dried compressed air
A D
B
E

INTEGRATED ENERGY RECOVERY C


Vp
As much as 90% of the electrical energy used by a compressed air solution is converted into heat. Using Atlas Copco’s integrated energy
recovery systems, it is feasible to recover up to 75% of that power input as hot air or hot water without any influence on the compressor’s
performance. Through efficient usage of the recovered energy, you bring about important energy cost savings and obtain a high return
on investment. A Intake air D Wet compressed air

B Air/oil mixture E Condensate

C Oil F Dried compressed air


ENERGY RECOVERY APPLICATIONS
 Auxiliary or main heating of warehouses, workshops etc.
 Industrial process heating.
 Water heating for laundries, industrial cleaning and sanitary facilities. GA 37, 45 VSD Width 1766 mm, 69.5"
H
 Canteens and large kitchens. GA 30+, 37+, 45+ Depth 970 mm, 38.2"
GA 37, 45 Height 1800 mm, 70.9"
 Food industry.
 Chemical and pharmaceutical industries. GA 55, 75, 90 VSD Width 2248 mm, 88.5"
 Drying processes. GA 55+, 75+ Depth 1080 mm, 42.5"
GA 55, 75, 90 Height 1955 mm, 76.9"

D W
Technical specifications GA 30+-90 (50 Hz versions) Technical specifications GA 30+-90 (60 Hz versions)
Max. working pressure Installed motor Noise Weight Weight WorkPlace Max. working pressure Installed motor Noise Weight Weight WorkPlace
Capacity FAD* COMPRESSOR Pressure Capacity FAD*
COMPRESSOR Pressure WorkPlace power level** WorkPlace Full Feature WorkPlace power level** WorkPlace Full Feature
TYPE variant TYPE variant
bar(e) psig l/s m3/min cfm kW hp dB(A) kg lbs kg lbs bar(e) psig l/s m3/min cfm kW hp dB(A) kg lbs kg lbs
GA 30+ 7.5 7.5 109 99 5.9 209 30 40 65 917 2022 998 2200 GA 30+ 100 7.4 107 100 6.0 212 30 40 65 917 2022 998 2200
8.5 8.5 123 90 5.4 191 30 40 65 917 2022 998 2200 125 9.1 132 91 5.5 192 30 40 65 917 2022 998 2200
10 10.0 145 82 4.9 175 30 40 65 917 2022 998 2200 150 10.8 157 82 4.9 174 30 40 65 917 2022 998 2200
13 13.0 189 71 4.3 151 30 40 65 917 2022 998 2200 175 12.5 181 75 4.5 158 30 40 65 917 2022 998 2200
GA 37 7.5 7.5 109 115 6.9 243 37 50 69 920 2028 1005 2216 GA 37 100 7.4 107 116 7.0 246 37 50 69 920 2028 1005 2216
8.5 8.5 123 106 6.4 225 37 50 69 920 2028 1005 2216 125 9.1 132 108 6.5 229 37 50 69 920 2028 1005 2216
10 10.0 145 100 6.0 213 37 50 69 920 2028 1005 2216 150 10.8 157 96 5.8 204 37 50 69 920 2028 1005 2216
13 13.0 189 81 4.9 172 37 50 69 920 2028 1005 2216 175 12.5 181 87 5.2 185 37 50 69 920 2028 1005 2216
GA 37+ 7.5 7.5 109 122 7.3 258 37 50 65 1002 2209 1087 2396 GA 37+ 100 7.4 107 120 7.2 255 37 50 65 1002 2209 1087 2396
8.5 8.5 123 118 7.1 250 37 50 65 1002 2209 1087 2396 125 9.1 132 111 6.7 234 37 50 65 1002 2209 1087 2396
10 10.0 145 102 6.1 216 37 50 65 1002 2209 1087 2396 150 10.8 157 100 6.0 212 37 50 65 1002 2209 1087 2396
13 13.0 189 85 5.1 180 37 50 65 1002 2209 1087 2396 175 12.5 181 91 5.4 192 37 50 65 1002 2209 1087 2396
GA 45 7.5 7.5 109 137 8.2 291 45 60 72 994 2191 1079 2379 GA 45 100 7.4 107 139 8.3 294 45 60 72 994 2191 1079 2379
8.5 8.5 123 127 7.6 268 45 60 72 994 2191 1079 2379 125 9.1 132 128 7.7 271 45 60 72 994 2191 1079 2379
10 10.0 145 117 7.0 248 45 60 72 994 2191 1079 2379 150 10.8 157 118 7.1 250 45 60 72 994 2191 1079 2379
13 13.0 189 102 6.1 217 45 60 72 994 2191 1079 2379 175 12.5 181 105 6.3 222 45 60 72 994 2191 1079 2379
GA 45+ 7.5 7.5 109 149 8.9 315 45 60 66 1070 2359 1160 2557 GA 45+ 100 7.4 107 146 8.8 310 45 60 66 1070 2359 1160 2557
8.5 8.5 123 139 8.3 295 45 60 66 1070 2359 1160 2557 125 9.1 132 134 8.0 284 45 60 66 1070 2359 1160 2557
10 10.0 145 128 7.7 270 45 60 66 1070 2359 1160 2557 150 10.8 157 126 7.5 266 45 60 66 1070 2359 1160 2557
13 13.0 189 106 6.4 225 45 60 66 1070 2359 1160 2557 175 12.5 181 111 6.7 236 45 60 66 1070 2359 1160 2557
GA 55 7.5 7.5 109 169 10.1 359 55 75 69 1329 2930 1429 3150 GA 55 100 7.4 107 174 10.5 369 55 75 69 1329 2930 1429 3150
8.5 8.5 123 159 9.5 337 55 75 69 1329 2930 1429 3150 125 9.1 132 154 9.3 327 55 75 69 1329 2930 1429 3150
10 10.0 145 148 8.9 313 55 75 69 1329 2930 1429 3150 150 10.8 157 142 8.5 300 55 75 69 1329 2930 1429 3150
13 13.0 189 126 7.6 267 55 75 69 1329 2930 1429 3150 175 12.5 181 128 7.7 272 55 75 69 1329 2930 1429 3150
GA 55+ 7.5 7.5 109 180 10.8 381 55 75 66 1458 3214 1558 3435 GA 55+ 100 7.4 107 181 10.9 384 55 75 67 1458 3214 1558 3435
8.5 8.5 123 172 10.3 364 55 75 66 1458 3214 1558 3435 125 9.1 132 163 9.8 345 55 75 67 1458 3214 1558 3435
10 10.0 145 153 9.2 324 55 75 66 1458 3214 1558 3435 150 10.8 157 136 8.3 292 55 75 67 1458 3214 1558 3435
GA 75 7.5 7.5 109 226 13.6 478 75 100 66 1371 3023 1491 3287 GA 75 100 7.4 107 225 13.5 476 75 100 67 1371 3023 1491 3287
8.5 8.5 123 209 12.5 444 75 100 73 1371 3023 1491 3287 125 9.1 132 198 11.9 424 75 100 73 1371 3023 1491 3287
10 10.0 145 190 11.4 401 75 100 73 1371 3023 1491 3287 150 10.8 157 186 11.2 401 75 100 73 1371 3023 1491 3287
13 13.0 189 162 9.7 344 75 100 73 1371 3023 1491 3287 175 12.5 181 169 10.1 358 75 100 73 1371 3023 1491 3287
GA 75+ 7.5 7.5 109 247 14.8 523 75 100 68 1525 3362 1645 3627 GA 75+ 100 7.4 107 247 14.8 523 75 100 69 1525 3362 1645 3627
8.5 8.5 123 232 13.9 492 75 100 68 1525 3362 1645 3627 125 9.1 132 226 13.6 479 75 100 69 1525 3362 1645 3627
10 10.0 145 207 12.4 439 75 100 68 1525 3362 1645 3627 150 10.8 157 201 12.1 426 75 100 69 1525 3362 1645 3627
13 13.0 189 173 10.4 367 75 100 68 1525 3362 1645 3627 175 12.5 181 179 10.7 379 75 100 69 1525 3362 1645 3627
GA 90 7.5 7.5 109 281 16.9 596 90 125 73 1525 3362 1645 3627 GA 90 100 7.4 107 284 17.0 602 90 125 74 1525 3362 1645 3627
8.5 8.5 123 275 16.5 582 90 125 73 1525 3362 1645 3627 125 9.1 132 262 15.7 555 90 125 74 1525 3362 1645 3627
10 10.0 145 250 15.0 529 90 125 73 1525 3362 1645 3627 150 10.8 157 245 14.7 519 90 125 74 1525 3362 1645 3627
13 13.0 189 216 13.0 458 90 125 73 1525 3362 1645 3627 175 12.5 181 224 13.4 475 90 125 74 1525 3362 1645 3627
* Unit performance measured according to ISO 1217, Annex C, Edition 4 Please refer to the footnotes, reference conditions and FAD details of the 50 Hz versions.
Reference conditions:
 Absolute inlet pressure 1 bar (14.5 psi)

 Intake air temperature 20°C, 68°F Technical specifications GA 37-90 VSD (50/60 Hz versions)
FAD is measured at the following working pressures:
 7.5 bar versions at 7 bar
Capacity FAD* Weight
 8.5 bar versions at 8 bar
Working Installed motor Noise Weight
COMPRESSOR WorkPlace
 10 bar versions at 9.5 bar
pressure power level** WorkPlace
TYPE l/s m3/min cfm Full Feature
 13 bar versions at 12.5 bar

** A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB). bar(e) psig min max min max min max kW hp dB(A) kg lbs kg lbs
Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.
GA 37 VSD 4 58 26.0 124 1.6 7.4 55 263 37 50 66/67 1142 2518 1227 2705
Pressure dew point of integrated refrigerant dryer at reference conditions: 2ºC to 3ºC, 36°F to 37°F.
7 102 26.0 123 1.6 7.4 55 260 37 50 66/67 1142 2518 1227 2705
10 145 25.8 107 1.5 6.4 55 226 37 50 66/67 1142 2518 1227 2705
13 189 40.3 87 2.4 5.2 85 185 37 50 66/67 1142 2518 1227 2705
GA 45 VSD 4 58 26.0 146 1.6 8.8 55 310 45 60 69/72 1200 2646 1290 2844
7 102 26.0 145 1.6 8.7 55 307 45 60 69/72 1200 2646 1290 2844
10 145 25.8 128 1.5 7.7 55 271 45 60 69/72 1200 2646 1290 2844
13 189 40.3 107 2.4 6.4 85 226 45 60 69/72 1200 2646 1290 2844
GA 55 VSD 4 58 32.4 197 1.9 11.8 69 418 55 75 69/72 1480 3263 1580 3483
7 102 26.0 175 1.6 10.5 55 371 55 75 69/72 1480 3263 1580 3483
10 145 25.4 155 1.5 9.3 54 328 55 75 69/72 1480 3263 1580 3483
13 189 37.0 129 2.2 7.7 78 273 55 75 69/72 1480 3263 1580 3483
GA 75 VSD 4 58 37.8 246 2.3 14.9 80 525 75 100 69/70 1632 3598 1752 3862
7 102 37.4 246 2.2 14.8 79 521 75 100 69/70 1632 3598 1752 3862
10 145 48.1 216 2.9 13.0 102 458 75 100 69/70 1632 3598 1752 3862
13 189 58.3 180 3.5 10.8 124 381 75 100 69/70 1632 3598 1752 3862
GA 90 VSD 4 58 37.0 290 2.2 17.4 78 614 90 125 73/74 1632 3598 1752 3862
7 102 39.4 289 2.4 17.3 84 612 90 125 73/74 1632 3598 1752 3862
10 145 48.3 254 2.9 15.2 102 536 90 125 73/74 1632 3598 1752 3862
13 189 59.4 212 3.6 12.5 126 443 90 125 73/74 1632 3598 1752 3862
* Unit performance measured according to ISO 1217, Annex E, Edition 4
Maximum working pressure for VSD machines: 13 bar(e) (188 psig)
2935 0814 42 © 2016, Atlas Copco Airpower NV, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the environment and the
people around us. We make performance stand the test of time. This is what we call –
Sustainable Productivity.

www.atlascopco.com
Oil-injected
rotary screw
compressors
GA 75-110 VSD+ (75-110 kW/100-150 hp)
Innovative
Atlas Copco has turned the compressed air industry on its
head by redesigning the conventional layout of a typical air
compressor. Instead of the normal space-taking horizontal
design, the new GA 75-110 VSD+ has an upright, vertical,
low-footprint layout. This saves valuable floor and work space,
eases maintenance access, accelerates manufacturing time,
and reduces the total cost of ownership for all customers.

Efficient
• On average 8% lower Specific Energy Requirement (SER)
than the current GA VSD models. Eco-efficient VSD+ reduces
energy consumption by on average 50% compared to the
current idling models.
• On top of energy savings, Free Air Delivery (FAD)
increase of up to 6% over the range. VSD
The new • The iPM motor outperforms IE4 efficiency levels.

revolutionary
compressor from Reliable
Atlas Copco • Completely enclosed frequency drive and drive train
ensure performance even in the harshest environments.
• Based on unique combination of proven technologies and
Atlas Copco’s GA 75-110 VSD+ brings a game- existing components, optimally brought together by Atlas
changing revolution in the compressor industry. It Copco’s experience and know-how.
offers Variable Speed Drive as standard, a powerful
motor and a compact footprint thanks to its in-house
designed iPM (Interior Permanent Magnet) motor
technology. The GA 75-110 VSD+ reduces energy Smart
• Easy monitoring and maintenance thanks to the
consumption by on average 50%, with uptimes
Elektronikon® Graphic controller.
assured even in the harshest operational conditions.
• Maintenance notifications and machine status available
The GA 75-110 VSD+ is the air compressor of the via SMARTLINK e-mail or text messages.
future, reducing electricity costs to a minimum • Customized reports on the energy performance of your
and maximizing uptime. It fits even in the smallest machine, in compliance with ISO 50001.
compressor room. The GA 75-110 VSD+ will set a
new standard for years to come, positioning Atlas
Copco as a leader in the compressed air industry.

2 - Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors - 3
7
INSIDE THE POWERFUL GA 75-110 VSD +
Innovative Neos inverter
• Atlas Copco’s in-house designed inverter,
now also controls iPM motors.
• IP5x protection.
• Robust aluminum enclosure for trouble-
free operation in the harshest conditions.
• Fewer components: compact, simple and
user-friendly.
1
Interior Permanent Magnet (iPM) motor
• Premium efficiency that exceeds IE4 levels.
• Compact, customized design for optimal cooling by oil.
• Designed in-house in Belgium.
• IP66 versus IP55.
• No cooling air flow required.
• Oil-lubricated motor bearing: no (re)grease(ing) and
5 5
increased uptime.

2 6 8 6
New compressor element
• Improved efficiency.
9
• Made by Atlas Copco.
• Robust and silent.
1 9
1
10 Elektronikon® Graphic controller
3
4 4
7 • Integrated smart algorithms reduce system pressure
Direct drive and energy consumption.

• Vertical design, less parts.



3 • Monitoring features include warning indications,
maintenance scheduling and online visualization of
• Oil-cooled, pressure-tight.

• No gears or belts, no shaft seal. 2 machine’s condition.

2
4
Inlet filter
• Heavy duty.
• Pressure drop indicator.

5
Cooling fan 6 8 10
• Already compliant with Classic cooler design Integrated dryer VSD+ Neos cubicle
future ERP2020 efficiency. • Ensures excellence in air quality. • VSD+ is superior to idling machines.
• Integrated water separation.
• Optimized, application-specific • Incorporates optional UD+ filter to meet ISO • Electrical components remain cool, enhancing
• Separate oil/air cooler.
design results in low noise 8573.1 Quality Class 1.4.2. lifetime of components.
and high efficiency. • Easy access for maintenance.
• True plug-and-play design eliminates cost of • Dedicated Neos drive for iPM technology motors.
installing a separate dryer. • Heat dissipation of inverter in separate compartment.

4 - Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors - 5
In almost every production environment, air demand fluctuates depending on different factors such
as the time of the day, week or even month. Extensive measurements and studies of compressed air
demand profiles show that many compressors have substantial variations in air demand.

Air demand Energy consumption

Time
Air demand Energy consumption
Fixed speed load/unload

Air demand Energy consumption

Time
Air demand GA VSD+ energy consumption

50% SAVINGS

VSD+ FOR 50% AVERAGE ENERGY SAVINGS


Atlas Copco’s GA Variable Speed Drive+ (VSD+) technology closely matches the air
demand by automatically adjusting the motor speed. Combined with the innovative
design of the iPM (Permanent Magnet) motor, this results in average energy savings of
50% and an average reduction of 37% in the lifecycle cost of a compressor. VSD+ works
with in-house designed permanent magnet motors.

Why Atlas Copco Variable Speed Drive+ technology?


• On average 50% energy savings with an extensive flow range (20-100%).
• Integrated Elektronikon® Graphic controller controls the motor speed and high efficiency frequency inverter.
• No wasted idling times or blow-off losses during operation. GA Fixed Speed GA VSD+
• Compressor can start/stop under full system pressure without the need to unload with special VSD motor.
+

• Eliminates peak current penalty during start-up.


• Minimizes system leakage due to a lower system pressure.
• EMC compliance to directives (2004/108/EG).
* Compared to fixed speed compressors, based on measurement performed by an independent energy audit agency.

Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors - 7


ADVANCED MONITORING,
CONTROL & CONNECTIVITY
Whether you call it Industry 4.0 or the Internet of Things (IoT), interconnectivity is the future.
The GA 75-110 VSD+ comes fully prepared. Its advanced monitoring, control and connectivity features allow
you to optimize compressor performance, resources, efficiency and productivity.

CONNECT
Dual Pressure Set Point SMARTLINK*: Data Monitoring Program
Create two different system pressure bands to reduce • Remote monitoring that helps you optimize your compressed air system and save energy and costs.
energy use and costs during fluctuating demand. • Provides a complete insight in your compressed air network.
• Anticipates potential problems by warning you up-front.
Integrated Saver Cycles * Please contact your local sales representative for more information.
Fan Saver Cycle reduces energy consumption
by switching off the fan in light load applications.

Timer
A built-in clock supports any working
schedule – per day, per week or
customized to your specific
EXCELLENCE IN INTEGRATED AIR QUALITY
situation and needs.
Untreated compressed air contains moisture and aerosols which increase the risk of corrosion and
compressed air system leaks. This can result in a damaged air system and contaminated end products.
Maintenance costs can far exceed air treatment costs. The GA 75-110 VSD+ provides the clean, dry air that
improves your system’s reliability, avoids costly downtime and production delays, and safeguards
the quality of your products.

On average 50% energy savings with newly designed integrated dryers


• Pressure dewpoint of 3°C /37.4°F (100% relative humidity at 20°C/68°F).
• Heat exchanger cross-flow technology with low pressure drop.
• Zero waste of compressed air thanks to no-loss condensate drain.
• Reduced operating costs.
• Environmentally-friendly characteristics; zero ozone depletion.
• Global warming potential has been lowered significantly by an average
of 50% by reducing the amount of refrigerant in the new dryer.

Meet your specific requirements


CONTROL Thanks to its integrated dryer, the Atlas Copco GA 75-110 VSD+ offers the right air quality for your application.
The Elektronikon® Graphic operating system
gives you the control and monitoring options to Compressed air purity classification ISO 8573-1:2010
optimize compressor performance. To maximize
energy efficiency, the Elektronikon® controls the Solid particles Water Total oil*
main drive motor and regulates system Purity Number of particles per m 3
Pressure dewpoint Concentration
class
pressure within
a predefined and narrow 0.1 < d ≤ 0.5 μm **
0.5 < d ≤ 1.0 μm **
1.0 < d ≤ 5.0 μm **
°C °F mg/m3
pressure band.
0 As specified by the equipment user or supplier and more stringent than Class 1.
1 ≤ 20000 ≤ 400 ≤ 10 ≤ -70 ≤ -94 ≤ 0.01
2 ≤ 400000 ≤ 6000 ≤ 100 ≤ -40 ≤ -40 ≤ 0.1
3 - ≤ 90000 ≤ 1000 ≤ -20 ≤ -4 ≤1
4 - - ≤ 10000 ≤3 ≤ 37.4 ≤5
5 - - ≤ 100000 ≤7 ≤ 44.6 - *
Liquid, aerosol and vapor.
6 ≤ 5 mg/m3 ≤ 10 ≤ 50 - **
d= diameter of the particle.

8 - Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors - 9
TECHNICAL SPECIFICATIONS GA 75-110 VSD+ FLOW CHART GA 75-110 VSD+
Weight
Weight
Working pressure Capacity FAD* (min-max) Installed motor power Noise level** WorkPlace
Type WorkPlace
Full Feature

bar(e) psig l/s m³/hr cfm kW hp dB(A) kg kg


50/60 Hz version
4 58 47-269 169-967 100-569 75 100 73 1207 1496
7 102 48-266 172-957 101-563 75 100 73 1207 1496
GA 75 VSD +

9.5 138 58-235 210-847 124-498 75 100 73 1207 1496


12.5 181 70-194 252-699 149-411 75 100 73 1207 1496
4 58 48-311 174-1121 102-660 90 125 74 1213 1503
7 102 49-306 176-1101 104-648 90 125 74 1213 1503
GA 90 VSD +
9.5 138 60-269 215-969 127-570 90 125 74 1213 1503 13
12.5 181 71-218 255-784 150-461 90 125 74 1213 1503
4 58 47-348 170-1251 100-736 110 150 76 1222 1573 16
7 102 49-345 175-1241 103-731 110 150 76 1222 1573 12
GA 110 VSD +
9.5 138 59-309 211-1111 124-654 110 150 76 1222 1573
12.5 181 71-268 254-965 150-568 110 150 76 1222 1573
11
* Unit performance measured according ISO 1217 ed. 4 2009, annex E, latest edition.
** Mean noise level measured at a distance of 1 m at max. working pressure according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method); tolerance 3 dB(A).

Reference conditions: 14
- Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20°C/68°F.

FAD is measured at the following effective working pressures:


- 4 bar(e)
- 7 bar(e)
15
- 9.5 bar(e)

- 12.5 bar(e)

Maximum working pressure: 13 bar(e) (188 psig) 10 9 8

Options 1
Energy recovery
Pre-filter

Tropical thermostat
FoodGrade oil 4
UD+ filter
RXD oil

ES4i, ES6i

Transformer sales kit 200-230V/500-575V

High ambient version 7
Power duct fan
2 5
6

1 Inlet filter 11 After cooler


Wet compressed air
D
W 2 VSD valve 12 Fan
3 Screw element 13 Oil cooler Condensate
4 Interior permanent magnet motor (iPM) 14 Electronic drain (one drain mounted on after
Dry compressed air
5 Air/oil vessel separator cooler for standard models, for Full Feature
6 Thermostatic bypass valve models a second drain is mounted on
Intake air
Standard Full Feature the ID dryer)
DIMENSIONS 7 Oil filter
8 Safety valve
15 Condensate prevention cycle Air/oil mixture
D (mm) W (mm) H (mm) D (in) W (in) H (in) D (mm) W (mm) H (mm) D (in) W (in) H (in)
16 Dryer
16
GA 75-110 VSD +
1400 1300 1968 55.12 51.18 77.48 2178 1300 1968 85.75 51.18 77.48 9 Minimum pressure valve Oil
10 Solenoid valve

10 - Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors Atlas Copco GA 75-110 VSD+ oil-injected rotary screw compressors - 11
COMMITTED TO SUSTAINABLE PRODUCTIVITY
We stand by our responsibilities towards our customers, towards the environment and the people around us.
We make performance stand the test of time. This is what we call – Sustainable Productivity.

2935 0817 42 © 2017, Atlas Copco Airpower NV, Belgium. All rights reserved.
Designs and specifications are subject to change without notice or obligation.
Read all safety instructions in the manual before usage.
OIL-INJECTED ROTARY
SCREW COMPRESSORS
GA 160+-315 (VSD) (160-315 kW/200-350 hp)
HIGHEST RELIABILITY, LOWEST
OPERATING COSTS
The shortest route to maximize your profitability is to minimize your operational cost. As energy consumption
is the major factor (up to 70%) of a compressor’s lifecycle cost, the Atlas Copco GA 160+-315 (VSD) compressors
are designed to help you achieve significant savings. The compressors provide high-quality compressed
air to meet your requirements even in the most demanding applications.

Mining industry
• Years of experience with thousands of compressors running
around the world.
• High product reliability with maximum uptime even
in harsh conditions.
• Strong global support network to provide 24/7 assistance
even in remote locations.

Energy industry
• Protect downstream equipment and increase component lifetime.
• Integrated water separator with electronic drain as standard.
• GA Full Feature decreases energy and installation costs.

Metal industry
• Easy and quick installation, with flexible ducting possibilities.
• A complete, ready-to-use solution including all components
and options.
• Low service cost thanks to high accessibility of components
and long service intervals.

General industry
• GA compressors are designed for ultimate efficiency
in all your industrial applications.
• Ideal for machinery operation, plant maintenance, cleaning,
pneumatic tools and controls, sand- and shot-blasting.
Reducing your operating costs
The GA 160+-315 (VSD) provide maximum output at the
lowest energy consumption. They will reduce your energy bill
and your CO2 emissions. The right core technologies with our
experience in design and manufacture combine to produce
a solution to match your needs. Generous cooling capacity,
low pressure drop and a highly efficient drive train ensure
optimum operation over a long lifetime.

Ensuring your peace of mind


The GA 160+-315 (VSD) optimize uptime by keeping your
production running, 24/7. The highly advanced controller
ensures optimum operation by controlling all compressor
inputs and outputs.

Easy installation and service


Easy to install, the ‘all-in-one’ package includes all necessary
equipment. There are no hidden costs, nor any extra devices
to install. Ducting is easy for increased flexibility. Service cost
is reduced to a minimum: all parts are easily accessible via
large opening doors, consumables are long-lasting,
and service operations are easy and safe to perform.

Protecting your production


With its integrated dryer, the GA FF (Full Feature) provides
dry compressed air (pressure dewpoint of +3°C/37°F),
while ensuring the lowest pressure drop and minimal
installation costs. This compact package offers fully integrated
functionalities such as saver cycle control that regulates the
dryer at optimum capacity. Moreover, each compressor has
an integrated Water Separator Drain as standard to remove
100% of condensate.

Maximizing your profitability


As there is no “one size fits all” concept, we have developed
a range of features and options to help you optimize the use
of your compressor: from running the machine at high
temperatures, to extra safety devices. Our highly skilled
engineering team can help you develop a customized
compressor based on your specific needs.
THE GA 160+-315 SETS A NEW STANDARD
IN THE INDUSTRY

1
High-efficiency
motor
• TEFC IP55 motor (Class F
insulation B rise) protects
against dust and chemicals.
• Continuous operation in
ambient temperatures up
to 55°C/131°F (standard up
to 46°C/115°F).
7
3
2
State-of-the-art screw element
• Patented asymmetric rotor profile and meticulous selection of bearings.
• Low wear and tear leads to increased reliability.
• Proven reliability with thousands of installations throughout the world.
6

3
2
Cooling module
• Separated oil and aftercoolers for highest efficiency. 4
• Axial cooling fans driven by separate TEFC electric motors
(IP55 protection).
• Low noise level.
5
4
Gear-driven transmission
• Maintenance-free; totally enclosed and protected against dirt and dust.
• Optimal working range of the screw element.
• Bowex coupling to absorb the trust load and increase the reliability.

5
Service-friendly
• Selection of long lifetime consumables.
• Easy and safe access to all service parts.
• Unique sliding system to access the oil coolers.
6
Optimized loading/unloading valve
• Ensures constant optimized pressure in the system,
resulting in significant energy savings.
• Simple, maintenance-free set-up with few moving parts
for highest reliability.
• Accurate control through solenoid valve.

7
Superior air quality
• Integrated water separator with electronic
drain removes 100% of condensate.
• Full Feature with integrated dryer
(up to 315 kW).

10 8
Easy to install
• Oil-containing frame as standard.
• All-in-one package, no hidden costs.
• Flexible ducting possibilities.

1 9
Superior air intake filter
• Protects the compressor components by removing
99.9% of dirt particles > 3 μm.
• Reduces the dust load in the fine filter, doubling the
filter element lifetime without reducing filter efficiency.

10
Elektronikon® for advanced monitoring
• Integrated smart algorithms reduce system pressure
and energy consumption.
• Monitoring features include warning indications, maintenance
scheduling and online visualization of machine’s condition.
VSD: DRIVING DOWN YOUR ENERGY COSTS
Over 70% of a compressor’s lifecycle cost is taken up by the energy it consumes. Moreover, the generation
of compressed air can account for more than 40% of a plant’s total electricity bill. To cut your energy costs,
Atlas Copco has pioneered Variable Speed Drive (VSD) technology for several decades. VSD leads to major
energy savings, reducing the consumption of energy producing fuels and protecting the environment
for future generations. Thanks to continual investments in this technology, Atlas Copco offers the widest
range of integrated VSD compressors on the market.

What is VSD technology?


In almost every production environment, air demand fluctuates depending on different factors (time of the day, week or even month).
Extensive measurements and studies of compressed air demand profiles show that many compressors have substantial variations
in air demand. Only 8% of all installations have a more stable air demand. Tests prove that, even in this case, VSD compressors
save energy.

Profile 1 Profile 2 Profile 3


MAX

MAX

MAX
• 64% of all installations. • 28% of all installations. • 8% of all installations.
• Factory working 24 hrs/day: • Factory working 2 shifts/day, • Factory working 2 shifts/day,
low demand at night & high no weekend work: erratically no weekend work: typical 'fixed'
demand during the day. varying air demand. speed application.

Energy savings on average up to 35%


Atlas Copco’s VSD technology closely follows the air demand
by automatically adjusting the motor speed. This results in large energy
savings of up to 35%. The Life Cycle Cost of a compressor can be cut
by an average of 22%. In addition, lowered system pressure with VSD
minimizes energy use across your production dramatically.

Total compressor lifecycle cost


Energy Investment

Energy savings with VSD Maintenance


WHAT IS UNIQUE ABOUT THE INTEGRATED
ATLAS COPCO GA VSD?

Efficiency
External VSD operating range

Atlas Copco VSD operating range

Min. Max. Flow Flow

Integrated VSD Non-integrated VSD Flow gaps due to vibration and noise issues

1 The Elektronikon® unit controller manages both the 7 A highly efficient frequency converter in a cool
compressor and the integrated converter, ensuring overpressure cubicle ensures stable operation in high
maximum machine safety within parameters. ambient temperatures up to 50°C/122°F
2 Flexible pressure selection from 4 to 13 bar with (standard up to 46°C/114.8°F).
electronic gearing reduces electricity costs. 8 It is important to ensure that when using a Variable Speed
3 Specific converter and motor design (with protected Drive vibration and noise issues do not occur. Atlas Copco
bearings) for the highest efficiency across the speed range. compressors are designed and tested to guarantee they
operate across the entire frequency range of operation.
4 Electric motor specifically designed for low operating
When an external VSD drive is used it may become
speeds with clear attention to motor cooling and
necessary to limit the operating range of the compressor,
compressor cooling requirements.
leading to reduced energy saving and jeopardizing stable
5 All Atlas Copco GA VSD compressors are EMC tested and air network pressure.
certified. Compressor operation does not influence
9 The cubicle cooling booster increases the lifetime
external sources and vice versa.
of electrical components due to a cool cubicle in
6 Mechanical enhancements ensure that all components overpressure and reduced dust ingress.
operate below critical vibration levels throughout the
10 Net pressure band is maintained within 0.10 bar, 1.5 psi.
entire compressor speed range.

No current peaks
% Full load current

Seconds

Star Delta DOL Soft Starter VSD


INCREASE YOUR SAVINGS WITH
ENERGY RECOVERY
The Kyoto directives and the continuing depletion of traditional energy sources mean that businesses
throughout the world are making commitments to significantly reduce overall energy consumption.
Through innovative products and solutions, Atlas Copco helps you achieve your goals in this area.
When it comes to compressed air production – where energy costs can constitute 70% of total lifecycle costs
– saving energy can also lead to substantial cost savings.

Integrated heat exchanger


Air compression creates heat that is normally wasted in the coolers. Energy recovery systems designed by Atlas Copco enable the
recovery of most of this heat. Recovery of energy from the shaft input of the compressor can be up to 94% of the compressor
shaft power. The heat is directly usable as a source of energy in the form of hot water (85-90°C/185- 194°F). The main module of the
recovery system is built into the compressor. The investment needed to link the hot oil circuit from the compressor to the existing
water circuit is relatively modest and the time needed before seeing payback from your investment is generally very short.

Shower Space heating Steam boiler Process Heat driven chillers Heat exchangers

Warm air heat recovery


The ducting on your GA compressors also constitutes a simple and smart solution to generate space heating. Ducting simply directs
the warmed cooling air to where it is needed – such as workshops, storage warehouses or other facilities. To cope with seasonal
changes, louver flaps can be used to vent the warm air to the outside. An installation with motorized and thermostatically
controlled louvers is the ideal solution to accurately monitor the temperature with a full control of the flow of heating air.

Applications:
• Heating of facilities, warehouses or workshops.
• Drying air for painting and washing applications.
PROTECT YOUR PRODUCTION WITH THE GA FF
Untreated compressed air contains moisture, aerosols and dirt particles that can damage your air system
and contaminate your end product, resulting in risk of corrosion and compressed air system leaks.
Maintenance costs can far exceed air treatment costs. Our compressors provide the clean, dry air that
improves your system’s reliability, avoids costly downtime and production delays, and safeguards the quality
of your products.

All-in-one quality air production


The GA FF (Full Feature) is a ready-to-use, compact package that guarantees a pressure dewpoint of 3°C/37°F (100% relative humidity
at 20°C/68°F). All the wires and pipes are assembled in the factory, so there is no need for additional installation work. The dryers can
perform at ambient conditions up to 46°C/115°F.

Save money and the environment Optimized air purity


The unique and patented Saver Cycle Control stops the The optional external filters and integrated refrigerant air dryer
dryer when the compressor is stopped or in unload mode, efficiently remove moisture, aerosols and dirt particles to protect
drastically reducing power consumption. The dewpoint is your investment. This air quality prolongs the life of downstream
continuously monitored and the dryer is re-started when equipment, increasing efficiency, reducing maintenance
the dewpoint begins to increase. requirements and ensuring quality of your final product.

Configure your GA
ISO Quality Class Dirt Particle Size Water Pressure Dew Point Oil Concentration
for the air quality you need

GA 3.-.4 3 microns - 3 ppm

GA FF with ID 3.4.4 3 microns +3°C, 37°F 3 ppm

GA FF with ID & general purpose


2.4.2 1 micron +3°C, 37°F 0.1 ppm
coalescing filter
MONITORING AND CONTROL:
HOW TO GET THE MOST FROM THE LEAST
The Elektronikon® unit controller is specially designed to maximize the performance of your compressors
and air treatment equipment under a variety of conditions. Our solutions provide you with key benefits such
as increased energy efficiency, lower energy consumption, reduced maintenance times and less stress…
less stress for both you and your entire air system.

Intelligence is part of the package


• High resolution color display gives you an easy to understand • Operation of the equipment to deliver specifically
readout of the equipment’s running conditions. and reliably to your compressed air needs.
• Clear icons and intuitive navigation provides you fast • Built in remote control and notifications functions
access to all of the important settings and data. provided as standard, including simple to use
• Monitoring of the equipment running conditions and Ethernet based communication.
maintenance status; bringing this information to • Support for 31 different languages, including character
your attention when needed. based languages.

Online & mobile monitoring


Monitor your compressors over the Ethernet with the
Elektronikon® unit controller. Monitoring features include
warning indications, compressor shut-down and
maintenance scheduling. An Atlas Copco App is available
for iPhone/Android phones as well as iPad and Android
tablets. It allows fingertip monitoring of your compressed
air system through your own secured network.
Full optimization -
ES system controller
Improve product quality every minute
that your facility is in operation.
Atlas Copco's ES system controllers
offer a convenient way to achieve
optimized performance from your low
pressure equipment through a single
centralized point of monitoring and
control. With the ES system controller
watching over your compressors and
compressed air network, you will have
a highly dependable and energy
efficient solution working with your
facility to manage operating costs.
Stores Measures

Protects

Controls

Communicates

Dual pressure set-point and Delayed Second Stop


Most production processes create fluctuating levels of demand which, in turn, can create energy waste in low use periods. Using the
graphic Elektronikon® unit controller, you can manually or automatically create two different system pressure bands to optimize energy
use and reduce costs at low use times. In addition, the sophisticated Delayed Second Stop (DSS) runs the drive motor only when
needed. As the desired system pressure is maintained while the drive motor’s run time is minimized, energy consumption is kept
to a minimum.

Without DSS With DSS


Power Power

Loaded
Loaded Unloaded

Unloaded Stopped

Time Time
Saved energy

SMARTLINK*: Data Monitoring Program


• A remote monitoring system that helps you optimize your
compressed air system and save you energy and cost.
• It offers you a complete insight in your compressed air
network and anticipates on potential problems by
warning you up-front.
*Please contact your local sales representative for more information.
OPTIMIZE YOUR SYSTEM
Scope of supply
Superior air inlet filters and flexibles
Air intake valve (not on VSD units)
Air circuit Full load/no load regulation system (not for VSD)

Heavy-duty oil filters


Complete oil circuit
Oil circuit Air/oil separation system

Compressed air aftercooler and oil cooler


Stainless steel tube and Shell coolers for water-cooled versions
Axial cooling fans for air-cooled versions.
Integrated water separator
Electronic water drains with no loss of compressed air
Cooling circuit Complete air, oil, water circuit

TEFC IP55 Class F IE3 electric motor


Starters* (Star-Delta)
Pre-mounted electrical VSD cubicles (only for VSD units)
Electrical components Elektronikon® unit controller

Flexible vibration dampers


Silenced canopy
Structural skid with no need for foundations
Framework Suppression of emissions/harmonic distortions

* Only for low voltage motors.

Additional features & options


GA 160+ -315 GA 200-315 VSD

Air treatment Full Feature: integrated ID refrigerant dryer • •


Winterization protection • -
Weather protection High ambient version* • •
Rain protection kit • -
Phase sequence relay • -
PT1000 thermal protection (windings and bearings) •
Anti-condensation heater in the main motor •
VSD cabinet heavy-duty filtration (applicable for VSDs) - •
Electrical protection
SPM vibration monitoring system • •
TT or TN network system
IT network system • •
High short circuit current rating (HSCCR) • •
Roto-Xtend duty fluid 8000h
NPT or ANSI connections • •
Anchor pads • •
Performance test certificate • •
Witnessed performance test • •
Material certificates • •
Seaworthy packaging • •
General options
Heavy-duty filter • •
Integrated Energy Recovery system • •
Separate air intake • •
Modulation control • -
Automatic water shut-off valve for water-cooled units • •
Thermostatic valve for water-cooled units - •
Medium voltage motor • -

* GA VSD 50ºC/122ºF. : Standard • : Optional - : Not available


FLOW CHARTS
Fixed speed: GA+ & GA

A Intake air F

B Air/oil mixture

C Oil

D Wet compressed air

E Condensate
E
F Dried compressed air

A D
B
E

C
Vp

A Intake air D Wet compressed air

B Air/oil mixture E Condensate


Variable Speed Drive:
C GA
Oil VSD F Dried compressed air

A Intake air

B Air/oil mixture

C Oil

D Wet compressed air F


E Condensate

F Dried compressed air

D
B
E

C
Vp

A Intake air D Wet compressed air

B Air/oil mixture E Condensate


TECHNICAL SPECIFICATIONS
GA 160+-315 (VSD) (50 Hz)
Working pressure Capacity FAD (1) Installed Weight
Noise
motor
level (2)
TYPE Standard Full Feature (3) Standard / Full Feature power Standard Full Feature

bar(e) psig bar(e) psig l/s m³/min cfm kW dB(A) kg lb kg lb

GA 160+ - 5.5 bar 5.5 80 5.3 77 621 37.2 1316 3624 7990 4081 8997
GA 160+ - 7.5 bar 7.5 109 7.3 106 538 32.2 1140 3624 7990 4081 8997
160 77
GA 160+ - 8.5 bar 8.5 123 8.3 120 498 29.8 1055 3197 7049 3654 8057
GA 160+ - 10 bar 10 145 9.8 142 448 26.9 949 3197 7049 3654 8057
GA 200 - 5.5 bar 5.5 80 5.3 77 748 44.8 1585 3624 7990 4217 9297
GA 200 - 7.5 bar 7.5 109 7.3 106 674 40.4 1428 4927 10862 5384 11870
GA 200 - 8.5 bar 8.5 123 8.3 120 632 37.9 1339 200 78 4927 10862 5384 11870
GA 200 - 10 bar 10 145 9.8 142 572 34.3 1212 4500 9922 4957 10929
GA 200 - 14 bar 14 203 13.8 200 440 26.4 932 4500 9922 4957 10929
GA 250 - 7.5 bar 7.5 109 7.3 106 833 49.9 1765 5144 11341 5737 12648
GA 250 - 8.5 bar 8.5 123 8.3 120 773 46.3 1638 5144 11341 5601 12348
250 78
GA 250 - 10 bar 10 145 9.8 142 709 42.5 1503 4717 10400 5174 11408
GA 250 - 14 bar 14 203 13.8 200 575 34.5 1219 4717 10400 5174 11408
GA 315 - 7.5 bar 7.5 109 7.3 106 1000 59.9 2119 5559 12256 6152 13563
GA 315 - 8.5 bar 8.5 123 8.3 120 955 57.2 2024 5559 12256 6152 13563
315 78
GA 315 - 10 bar 10 145 9.8 142 891 53.4 1888 5132 11315 5725 12622
GA 315 - 14 bar 14 203 13.8 200 745 44.7 1579 5132 11315 5589 12323

Working pressure Capacity FAD (1) Installed Weight


Noise
motor
level (2)
TYPE Standard Full Feature (3) Standard / Full Feature power Standard Full Feature

bar(e) psig bar(e) psig l/s m³/min cfm kW dB(A) kg lb kg lb


Minimum 5 72 5 72 211 - 806 12.7 - 48.4 447 - 1708
GA 200 VSD - Nominal 7 101 7 101 206 - 716 12.4 - 43.0 436 - 1517 200 77 5682 12527 6221 13715
8.5 bar
Maximum 8.5 123 8.3 120 202 - 656 12.1 - 39.4 428 - 1390
Minimum 6 87 6 87 100 - 611 6.0 - 36.7 212 - 1295
GA 200 VSD - Nominal 9.5 138 9.5 138 97 - 600 5.8 - 36.0 206 - 1271 200 80 4352 9594 4891 10783
10 bar
Maximum 10 145 9.8 142 96 - 584 5.8 - 35.0 203 - 1237
Minimum 9 131 9 131 98 - 608 5.9 - 36.5 208 - 1288
GA 200 VSD - Nominal 13.5 196 12.5 181 86 - 504 5.2 - 30.2 182 - 1068 200 80 4352 9594 4891 10783
14 bar
Maximum 14 203 12.8 185 84 - 495 5.0 - 29.7 178 - 1049
Minimum 5 72 5 72 211 - 900 12.7 - 54.0 447 - 1907
GA 250 VSD - Nominal 7 101 7 101 206 - 876 12.4 - 52.6 436 - 1856 250 80 5682 12527 6301 13891
8.5 bar
Maximum 8.5 123 8.3 120 202 - 808 12.1 - 48.5 428 - 1712
Minimum 6 87 6 87 208 - 899 12.5 - 53.9 441 - 1905
GA 250 VSD - Nominal 9.5 138 9.5 138 200 - 767 12.0 - 46.0 424 - 1625 250 77 5255 11585 5874 12950
10 bar
Maximum 10 145 9.8 142 198 - 748 11.9 - 44.9 420 - 1585
Minimum 5 72 5 72 211 - 1051 12.7 - 63.1 447 - 2237
GA 315 VSD - Nominal 7 101 7 101 206 - 1049 12.4 - 62.9 436 - 2223 315 79 5792 12769 6411 14134
8.5 bar
Maximum 8.5 123 8,3 120 202 - 992 12.1 - 59.5 428 - 2102
Minimum 6 87 6 87 208 - 1050 12.5 - 63.0 441 - 2225
GA 315 VSD - Nominal 9.5 138 9.5 138 200 - 947 12.0 - 56.8 424 - 2007 315 80 5365 11828 5984 13192
10 bar
Maximum 10 145 9.8 142 198 - 925 11.9 - 55.5 420 - 1960

(1) Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009).
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).

DIMENSIONS
- Intake air temperature 20°C (68°F).

(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa)
dB (with uncertainty 3 dB). Values determined according to noise level test code
L W H ISO 2151 and noise measurement standard ISO 9614. Pressure dew point of
integrated refrigerant dryer at reference conditions: 2°C to 3°C (36°F to 37°F).
mm
GA 160+-315 A/W 3400 2000 2300 (3) Integrated dryer: compressed air pressure dewpoint at dryer
GA 160+-315 A - FF 4300 2000 2300 reference conditions 3°C (37°F).

GA 160+-315 W - FF 3400 2000 2300 FAD (1) is measured at the following working pressures:
GA 160+-315 A/W (MV) 3700 2000 2300
GA 160+-315 A - FF (MV) 4600 2000 2300 Standard FF
GA 160+-315 W - FF (MV) 3700 2000 2300 5.5 bar version at 5 bar 5 bar
GA 200-315 VSD A 3700 2000 2300 7.5 bar version at 7 bar 7 bar
GA 200-315 VSD A - FF 4600 2000 2300 8.5 bar version at 8 bar 8 bar
GA 200-315 VSD W 3700 2000 2300 10 bar version at 9.5 bar 9.5 bar
GA 200-315 VSD W - FF 3700 2000 2300 14 bar version at 13.5 bar 12.5 bar

A = air-cooled.
W = water-cooled.
FF = Full Feature.
TECHNICAL SPECIFICATIONS
GA 160+-315 (VSD) (60 Hz)
Working pressure Capacity FAD (1) Installed Weight
Noise
motor
level (2)
TYPE Standard Full Feature (3) Standard / Full Feature power Standard Full Feature

bar(e) psig bar(e) psig l/s m³/min cfm hp dB(A) kg lb kg lb

GA 160+ - 75 psi 5.5 80 5.3 77 580 34.8 1229 77 4712 10388 5169 11396
GA 160+ - 100 psi 7.4 107 7.2 104 511 30.6 1083 77 4712 10388 5169 11396
200
GA 160+ - 125 psi 9.1 132 8.9 129 446 26.7 945 77 4285 9448 4742 10455
GA 160+ - 150 psi 10.9 158 10.7 155 397 23.8 841 75 4285 9448 4742 10455
GA 200 - 75 psi 5.5 80 5.3 77 711 42.6 1507 77 4712 10388 5305 11696
GA 200 - 100 psi 7.4 107 7.2 104 633 37.9 1341 77 4892 10785 5349 11793
GA 200 - 125 psi 9.1 132 8.9 129 576 34.5 1221 250 77 4465 9845 4922 10852
GA 200 - 150 psi 10.9 158 10.7 155 505 30.3 1070 77 4465 9845 4922 10852
GA 200 - 200 psi 14 203 13.8 200 405 24.3 858 75 4465 9845 4922 10852
GA 250 - 100 psi 7.4 107 7.2 104 759 45.5 1608 78 5014 11054 5607 12361
GA 250 - 125 psi 9.1 132 8.9 129 694 41.6 1471 77 5014 11054 5471 12062
300
GA 250 - 150 psi 10.9 158 10.7 155 627 37.6 1329 77 4587 10114 5044 11121
GA 250 - 200 psi 14 203 13.8 200 526 31.5 1115 77 4587 10114 5044 11121
GA 315 - 100 psi 7.4 107 7.2 104 925 55.4 1960 78 5654 12465 6247 13772
GA 315 - 125 psi 9.1 132 8.9 129 855 51.2 1812 78 5654 12465 6247 13772
350
GA 315 - 150 psi 10.9 158 10.7 155 784 47.0 1661 78 5227 11525 5820 12832
GA 315 - 200 psi 14 203 13.8 200 667 40.0 1414 77 5227 11525 5684 12532

Working pressure Capacity FAD (1) Installed Weight


Noise
motor
level (2)
TYPE Standard Full Feature (3) Standard / Full Feature power Standard Full Feature

bar(e) psig bar(e) psig l/s m³/min cfm hp dB(A) kg lb kg lb


Minimum 5 72 5 72 211 - 806 12.7 - 48.4 447 - 1708
GA 200 VSD - 8.6 Nominal 6.9 100 6.9 100 206 - 721 12.4 - 43.3 436 - 1528 268 77 5682 12527 6221 13715
bar (125 psi)
Maximum 9.1 132 8.9 129 201 - 638 12.1 - 38.3 426 - 1352
Minimum 6 87 6 87 100 - 611 6.0 - 36.7 212 - 1295
GA 200 VSD - 10.4 Nominal 10.4 151 10.4 151 95 - 574 5.7 - 34.4 201 - 1216 268 80 4352 9594 4891 10783
bar (150 psi)
Maximum 10.9 158 10.7 155 94 - 562 5.6 - 33.7 199 - 1191
Minimum 9 131 9 131 98 - 608 5.9 - 36.5 208 - 1288
GA 200 VSD - 13.8 Nominal 13.5 196 12.5 181 86 - 505 5.2 - 30.3 182 - 1070 268 80 4352 9594 4891 10783
bar (200 psi)
Maximum 14 203 12.8 185 84 - 495 5.0 - 29.7 178 - 1049
Minimum 5 72 5 72 211 - 900 12.7 - 54.0 447 - 1907
GA 250 VSD - 8.6 Nominal 6.9 100 6.9 100 206 - 881 12.4 - 52.9 436 - 1867 335 80 5682 12527 6301 13891
bar (125 psi)
Maximum 9.1 132 8.9 129 201 - 787 12.1 - 47.2 426 - 1668
Minimum 6 87 6 87 208 - 899 12.5 - 53.9 441 - 1905
GA 250 VSD - 10.4 Nominal 10.4 151 10.4 151 197 - 733 11.8 - 44.0 417 - 1553 335 77 5255 11585 5874 12950
bar (150 psi)
Maximum 10.9 158 10.7 155 196 - 714 11.8 - 42.8 415 - 1513
Minimum 5 72 5 72 211 - 1051 12.7 - 63.1 447 - 2227
GA 315 VSD - 8.6 Nominal 6.9 100 6.9 100 206 - 1049 12.4 - 62.9 436 - 2223 422 79 5792 12769 6411 14134
bar (125 psi)
Maximum 9.1 132 8.9 129 201 - 968 12.1 - 58.1 426 - 2051
Minimum 6 87 6 87 208 - 1050 12.5 - 63.0 441 - 2225
GA 315 VSD - 10.4 Nominal 10.4 151 10.4 151 197 - 908 11.8 - 54.5 417 - 1924 422 80 5365 11828 5984 13192
bar (150 psi)
Maximum 10.9 158 10.7 155 196 - 886 11.8 - 53.2 415 - 1877

(1) Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009).
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).

DIMENSIONS
- Intake air temperature 20°C (68°F).

(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa)
dB (with uncertainty 3 dB). Values determined according to noise level test code
L W H ISO 2151 and noise measurement standard ISO 9614. Pressure dew point of
inch integrated refrigerant dryer at reference conditions: 2°C to 3°C (36°F to 37°F).

GA 160+-315 A/W 134 79 91 (3) Integrated dryer: compressed air pressure dewpoint at dryer
GA 160+-315 A - FF 169 79 91 reference conditions 3°C (37°F).

GA 160+-315 W - FF 134 79 91 FAD (1) is measured at the following working pressures:


GA 160+-315 A/W (MV) 146 79 91
GA 160+-315 A - FF (MV) 181 79 91 Standard FF
GA 160+-315 W - FF (MV) 146 79 91 75 psi version at 73 psi 73 psi
GA 200-315 VSD A 146 79 91 100 psi version at 100 psi 100 psi
GA 200-315 VSD A - FF 181 79 91 125 psi version at 125 psi 125 psi
GA 200-315 VSD W 146 79 91 150 psi version at 150 psi 150 psi
GA 200-315 VSD W - FF 146 79 91 200 psi version at 196 psi 181 psi

A = air-cooled.
W = water-cooled.
FF = Full Feature.
2935 0626 11 © 2015, Atlas Copco, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety instructions in the manual before usage.

COMMITTED TO SUSTAINABLE PRODUCTIVITY


We stand by our responsibilities towards our customers, towards the environment and the
people around us. We make performance stand the test of time. This is what we call –
Sustainable Productivity.

www.atlascopco.com
Oil-injected rotary
screw compressors

GA 90+ – 160 (VSD+)


Highest reliability,
lowest operating
costs
The shortest route to maximize your profitability is to minimize your

operational costs. With up to 80% of a compressor lifecycle cost

coming from the energy it consumes, this should be a clear focus.

Atlas Copco's GA compressors with SmartInjection enabled

compression elements and IE4 or better class motors are designed to

achieve significant energy savings while providing long and trouble-

free life even in the harshest environmental conditions.

GA 90+ – 160 (VSD+)


Efficiency
At the heart of the GA compressors are state-of-the-art

compression elements with SmartInjection technology and high

efficiency oil cooled IE4 or better class motors. This highly

efficient drive train coupled with generous cooling capacity, low

internal pressure drops and precise control from the

Elektronikon® Touch ensures optimum efficiency.

Reliability
The GA compressor's drive train is IP66 rated protecting it

completely from environmental dust and moisture ensuring it can

operate reliably in the toughest conditions and at ambient

temperatures up to 55°C/131°F.

Serviceability
Service time is reduced to a minimum with all service parts

grouped together for ease of access and, if greater assess is

required, the patented portal design enables full access to all

components. Each component has also been designed for

serviceability, halving the time required to service compared to

traditional designs.

3
Installations around the world
Thousands of GA compressors are running around the world in a vast range of applications delivering reliable and

efficient compressed air.

General industry
Lowest life cycle cost

For industrial companies compressed air is essential in

their daily operations that include pneumatic tools for

cutting, drilling, hammering and grinding; pneumatic

actuators and valves; ventilation systems; packing and

palletizing machinery and many more. GA compressors

are designed for lowest lifecycle cost.

Mining
Operating in the toughest conditions

Compressed air is vital for the mining industry. Uses

include dust bag filtration, service air, ventilation air and

powering pneumatic tools. The reliability and robustness

of GA compressors will accomplish the job even in the

harshest conditions.

GA 90+ – 160 (VSD+)


Power plants
Reliable and dependable

Power plants run round-the-clock to supply vital energy

with a continuous supply of compressed air, critical for

trouble-free operation. GA compressors provide a reliable

source of compressed air for applications such as soot

blowing and fly ash handling.

Metal plants
Ultimate efficiency

Metal plants use compressed air for instrumentation,

plant air and pneumatic conveying of raw materials or

ash. Metal plants are in need of an efficient solution to

reduce their operating costs and to meet environmental

targets. Our GA air compressors are designed to meet

this demand.

Cement industry
Easy to maintain and service

Cement works are one of the biggest consumers for

compressed air with the vast majority of air used for

transporting raw materials within the factory. If moisture,

dust, or other contaminants are present in the

environment it can impair compressor performance,

resulting in excess energy consumption and maintenance

costs. GA compressor not only have an IP66 rated drive

train that prevents contaminants from entering the

compressor, they are also easy to maintain and service

with a grouped service area and slide out coolers.

5
GA air-cooled fixed speed pack

Always operates reliably and at peak High efficiency IE4 motor


efficiency • Oil cooled motors require no service interventions.
• SmartInjection provides exact amount of oil required to • IP66 rated for increased reliability even in tough environments.
element ensuring it always works at peak efficiency in different
conditions.
• Separate oil flow to bearings for longer life and greater uptime.

GA 90+ – 160 (VSD+)


GA water-cooled fixed speed FF

Reduced service time for greater Ready-to-use compact package


uptime • The GA Full Feature comes with an integrated dryer.
• Multiple smaller cartridges simplify and reduce service times • Guaranteed dew point of 3°C/37°F.
and minimize oil carry over. • No additional installation work of wires and pipes.
• Reduced power consumption due to unique and patented Save
Cycle Control stops the dryer when the compressor is stopped
or in unload mode.
• Continuously monitored dew point.

7
GA water-cooled VSD pack

Ease of maintenance Up to 78% of energy recovered as hot


• Minimal service times with service parts grouped together for
water
ease of access.
• Optional integrated energy recovery system.
• Portal design enables full access to all components.
• Up to 78% energy recovered from integrated motor and
• All components are designed for serviceability. element oil circuit.

GA 90+ – 160 (VSD+)


GA air-cooled VSD FF

Operate at temperatures up to 46°C High efficiency IE5 Permanent


(115°F) as standard Magnet motor
• VSD fan delivers energy efficiency in lower temperatures. • No need for external cooling because of oil cooled motors.
• Increased reliability and fewer service interventions.
• IP66 rated motor.

9
VSD: driving down energy costs
Variable Speed Drive

Driving down energy costs


Over 80% of a compressor’s lifecycle cost is taken up by the energy it consumes. Moreover, the

generation of compressed air can account for more than 40% of a plant’s total electricity bill. To cut your

energy costs, Atlas Copco pioneered Variable Speed Drive (VSD) technology in the compressed air

industry. VSD leads to major energy savings, while protecting the environment for future generations.

Thanks to continual investments in this technology, Atlas Copco offers the widest range of integrated

VSD compressors on the market.

Energy savings up to 35%


Atlas Copco's VSD technology closely follows the air demand by

automatically adjusting the motor speed. This results in large

energy savings of up to 35%. The Life Cycle Cost of a compressor

can be cut by an average of 22%. In addition, lowered system

pressure with VSD minimizes energy use across your production

dramatically.

What is unique about the integrated Atlas Copco VSD?


1. The Elektronikon® controls both the compressor and the integrated converter, ensuring maximum

machine safety within parameters.

2. Flexible pressure selection with VSD reduces electricity costs.

3. Specific converter and motor design (with protected bearings) for the highest efficiency across the

speed range.

4. Electric motor specifically designed for low operating speeds with clear attention to motor cooling and

compressor cooling requirements.

5. All Atlas Copco VSD compressors are EMC tested and certified. Compressor operation does not

influence external sources and vice versa.

6. Mechanical enhancements ensure that all components operate below critical vibration levels

throughout the entire compressor speed range.

7. A highly efficient frequency converter in a cubicle ensures stable operation in high ambient

temperatures up to 50°C/122°F

8. No ‘speed windows’ that can jeopardize the energy savings and the stable net pressure. Turndown

capability of the compressor is maximized to 70-75%.

9. Net pressure band is maintained within 0.10 bar, 1.5 psi.

GA 90+ – 160 (VSD+)


Monitoring and control
How to get the most from the least

Elektronikon® MK5 Touch


The Elektronikon® unit controller is specially designed to maximize the performance of your compressors

and air treatment equipment under a variety of conditions. Our solutions provide you with key benefits

such as increased energy efficiency, lower energy consumption, reduced maintenance times and less

stress… less stress for both you and your entire air system.

Intelligence is part of the package


The full color touch display gives you an easy to understand readout

of the equipment’s running conditions.

• Clear icons and intuitive navigation provides you fast access to all
of the important settings and data.
• Monitoring of the equipment running conditions and
maintenance status; bringing this information to your attention
when needed.
• Operation of the equipment to deliver specifically and reliably to
your compressed air needs.
• Built in remote control and notifications functions provided as
standard, including simple to use integrated webpage.
• Integrated SMARTLINK
• Support for 31 different languages, including character based
languages.

Online & mobile monitoring


Monitor your machines over the ethernet with the Elektronikon®

unit controller and the SMARTLINK service. Monitoring features

include warning indications, compressor shut-down, sensor

trending and maintenance scheduling.

11
Dual set-point and automatic stop
Most production processes create fluctuating levels of demand which, in turn, can create energy waste in

low use periods. Using the Elektronikon® unit controller, you can manually or automatically switch

between two different setpoints to optimize energy use and reduce costs at low use times. In addition,

the sophisticated algorithm runs the drive motor only when needed. As the desired setpoint is maintained

while the drive motor’s run time is minimized, energy consumption is kept to a minimum.

SMARTLINK
Monitor your compressed air installation with SMARTLINK

Knowing the status of your compressed air equipment at all times is the surest way to achieve optimal

efficiency and maximum availability.

Go for energy efficiency

Customized reports on the energy efficiency of your compressor room.

Increase uptime

All components are replaced on time, ensuring maximum uptime.

Save money

Early warnings avoid breakdowns and production loss.

GA 90+ – 160 (VSD+)


Optimize your compressed air system
Minimizing Excess Pressure

Optimizer 4.0 minimizes the generation of excess compressed air by starting and stopping compressors.

Its user friendly interface enables you to set multiple pressure bands, allowing you to optimize your

compressor installation for varying circumstances, such as non-productive hours.

Full VSD Benefits

With Optimizer 4.0 you can realize the full energy saving potential of VSD (Variable Speed Drive). It

regulates the VSD to ensure that the compressed air output is proportional to the demand, preventing

higher pressures than required, excess unloaded running, and spiraling energy costs.

Improving Uptime

Optimizer 4.0 effectively eliminates production downtime caused by unexpected system pressure drops,

because it regulates the system pressure instead of the compressor output pressure.

This means Optimizer 4.0 will automatically adjust the system pressure to compensate for pressure

drops due to filters, piping and dryers for example.

We also provide additional functionality and services on Optimizer 4.0 to ensure that your energy savings

will stand the test of time. Even when your installation needs adaptations or your demand changes.

13
Services
Properly caring for your air compressor helps you lower your operating costs and minimises the risk for unplanned

breakdowns or production stops. Atlas Copco offers energy efficiency checks, service, repairs, spare parts and

maintenance plans for all air compressors. Entrust your servicing to our expert professionals and ensure your business

continues to run efficiently. Our plans cover repairs, preventative maintenance, spare parts, and more.

Compressor oils, lubricants and fluids


Every type of compressor and vacuum pump needs a specific oil to achieve maximum uptime,

performance and lifetime. Our compressed air fluids and lubricants cover all your needs.

Unique mix of additives

Tailored to the specific needs of your equipment.

Anti-oxidation

The high-quality oil ensures maximum protection.

Prevent foaming

Anti-foaming improves your air quality.

GA 90+ – 160 (VSD+)


Maximize your resources with a Service Plan
Reduce your total cost of ownership and benefit from optimal performance

Save costs

Optimal maintenance will reduce the operational cost of your compressed air and vacuum system.

Increase operational efficiency

Our maintenance expertise makes life easier when it comes to resource management.

High uptime and performance

Specialist service keeps your equipment running as it should, protecting your investment.

15
Customized to your needs
A range of optional features are available to ensure the GA compressor is customized to the applications requirements

High ambient temperature variant


Reliable and continuous operation of the compressor in hot and

humid environments up to :

– max. 55°C ( 131°F ) for fixed speed pack

– max. 50°C ( 121°F ) for VSD pack

Shock pulse monitoring


Continuous SPM “Shock Pulse Measurement” monitoring system

of the compressor element & motor bearings. The sensors are

connected to the Elektronikon® which is showing the individual

vibration levels.

Alarm and/or shutdown levels can be programmed during

commissioning of the compressor. With this monitoring system,

the compressor can run longer, since overhaul can be done when

needed and preventive maintenance can be organized.

Energy recovery
The energy recovery system consists of a build-in stainless steel

heat exchanger and thermostatic controlled system to recover the

heat from the compressor in the form of warm water or hot water

without any adverse influence on the compressor performance.

GA 90+ – 160 (VSD+)


Witness and performance test
Factory visit and witnessing of the standard performance test of

the compressor. The compressor is tested following the Atlas

Copco standard test procedure in accordance to the ISO 1217:

2009, annex “C” and “E” (4th edition) for full transparency and

peace of mind.

Food grade oil


The option “Roto-Foodgrade oil” allows you to operate the

compressor in industries like packaging, pharmaceutical and food

and beverage industry, where occasional contact is allowed in and

around food processing areas.

Integrated dryer
In a GA Full Feature compressor the refrigeration dryer is fully

integrated in the compressor unit. This “all-in-one” feature not only

reduces the space requirement for installing the compressor but

also provides savings on piping installation cost.

Typical dew point of a refrigerant dryer is +3°C (37.4°F) at reference

conditions.

Motor thermal protection


Five (PT-1000) temperature sensors are installed in the main motor

of which 2 sensors are monitoring the bearings and 3 sensors are

monitoring the windings.

The relevant temperatures are shown on the Elektronikon® display

and alarms and shutdowns are programmed to protect the

compressor motor.

17
Flow diagrams GA
Process flow, oil flow and cooling flow - step by step

GA 90+ – 160 (VSD+)


19
Technical specifications
GA 90+ - 160 (50 Hz)
Maximum working pressure Capacity FAD (1) Installed Weight
Noise level
motor
Standard / (2)
TYPE Standard Full Feature (3) power Standard Full Feature (3)
Full Feature (3)
bar(e) psig bar(e) psig l/s m /min
3
cfm hp dB(A) kg lb kg lb

GA 90+ - 5.5 bar 5.5 80 5.3 77 353 21.2 748 2800 6173 3200 7055

GA 90+ - 7.5 bar 7.5 109 7.3 106 297 17.8 629 2800 6173 3200 7055
90 76
GA 90 - 8.5 bar
+
8.5 123 8.3 120 284 17.0 602 2800 6173 3200 7055

GA 90+ - 10 bar 10 145 9.8 142 260 15.6 551 2800 6173 3200 7055

GA 110 - 5.5 bar 5.5 80 5.3 77 424 25.4 898 2700 5952 3100 6834

GA 110 - 7.5 bar 7.5 109 7.3 106 370 22.2 784 2700 5952 3100 6834
110 77
GA 110 - 8.5 bar 8.5 123 8.3 120 347 20.8 735 2700 5952 3100 6834

GA 110 - 10 bar 10 145 9.8 142 316 19.0 670 2700 5952 3100 6834

GA 132 - 5.5 bar 5.5 80 5.3 77 502 30.1 1064 2800 6173 3200 7055

GA 132 - 7.5 bar 7.5 109 7.3 106 440 26.4 932 2800 6173 3200 7055
132 78
GA 132 - 8.5 bar 8.5 123 8.3 120 414 24.8 877 2800 6173 3200 7055

GA 132 - 10 bar 10 145 9.8 142 382 22.9 809 2800 6173 3200 7055

GA 160 - 7.5 bar 7.5 109 7.3 106 525 31.5 1112 2900 6393 3300 7275

GA 160 - 8.5 bar 8.5 123 8.3 120 495 29.7 1049 160 78 2900 6393 3300 7275

GA 160 - 10 bar 10 145 9.8 142 460 27.6 975 2900 6393 3300 7275

(1) Unit performance measured according to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20°C (68°F).

(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.

(3) Integrated dryer (FF) : compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).

FAD(1) is measured at the following working pressures:


Standard FF

5.5 bar version at 5 bar 5 bar

7.5 bar version at 7 bar 7 bar

8.5 bar version at 8 bar 8 bar

10 bar version at 9.5 bar 9.5 bar

Dimensions
L W H

mm mm mm

GA 90+ - 160 2500 1785 2020

GA 90+ - 160 (FF) 2900 1785 2020


Technical specifications
GA 90+ - 160 (60 Hz)
Maximum working pressure Capacity FAD (1) Installed Weight
Noise level
motor
Standard / (2)
TYPE Standard Full Feature (3) power Standard Full Feature (3)
Full Feature (3)
bar(e) psig bar(e) psig l/s m /min
3
cfm hp dB(A) kg lb kg lb

GA 90+ - 75 psi 5.5 80 5.3 77 316 19.0 670 3100 6834 3450 7606

GA 90+ - 100 psi 7.4 107 7.2 104 303 18.2 642 3100 6834 3450 7606
125 76
GA 90 - 125 psi
+
9.1 132 8.9 129 271 16.3 574 3100 6834 3450 7606

GA 90+ - 150 psi 10.9 158 10.7 155 243 14.6 515 3100 6834 3450 7606

GA 110 - 75 psi 5.5 80 5.3 77 425 25.5 901 2600 5732 3050 6724

GA 110 - 100 psi 7.4 107 7.2 104 372 22.3 788 2600 5732 3050 6724
150 77
GA 110 - 125 psi 9.1 132 8.9 129 333 20.0 706 2600 5732 3050 6724

GA 110 - 150 psi 10.9 158 10.7 155 298 17.9 631 2600 5732 3050 6724

GA 132 - 75 psi 5.5 80 5.3 77 505 30.3 1070 2700 5952 3150 6945

GA 132 - 100 psi 7.4 107 7.2 104 446 26.8 945 2700 5952 3150 6945
175 77
GA 132 - 125 psi 9.1 132 8.9 129 400 24.0 848 2700 5952 3150 6945

GA 132 - 150 psi 10.9 158 10.7 155 354 21.2 750 2700 5952 3150 6945

GA 160 - 100 psi 7.4 107 7.2 104 529 31.7 1121 2900 6393 3250 7165

GA 160 - 125 psi 9.1 132 8.9 129 480 28.8 1017 215 78 2900 6393 3250 7165

GA 160 - 150 psi 10.9 158 10.7 155 439 26.3 930 2900 6393 3250 7165

(1) Unit performance measured according to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20°C (68°F).

(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).
Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.

(3) Integrated dryer (FF) : compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).

FAD(1) is measured at the following working pressures:


Standard FF

75 psi version at 73 psi 73 psi

100 psi version at 100 psi 100 psi

125 psi version at 125 psi 125 psi

150 psi version at 150 psi 150 psi

Dimensions
L W H

inch inch inch

GA 90+ - 160 98.5 70.3 79.5

GA 90+ - 160 (FF) 114.2 70.3 79.5


Technical specifications
GA 110-160 VSD+ (50 Hz)
Maximum working pressure Capacity FAD (1) Installed Weight
Noise
motor
Standard / level (2)
TYPE Standard Full Feature (3) power Standard Full Feature (3)
Full Feature (3)
bar(e) psig bar(e) psig l/s m /min
3
cfm kW dB(A) kg lb kg lb

Minimum 5 72 5 72 104 - 407 6.2 - 24.4 220 - 862


GA 110 VSD+ -
Nominal 7 101 7 101 101 - 390 6.1 - 23.4 214 - 826 110 77 2400 5291 2800 6173
8.5 bar
Maximum 8.5 123 8.3 120 100 - 356 6.0 - 21.4 212 - 754

Minimum 6 87 6 87 102 - 405 6.1 - 24.3 216 - 858


GA 110 VSD+ -
Nominal 9.5 138 9.5 138 97 - 332 5.8 - 19.9 206 - 703 110 77 2400 5291 2800 6173
10 bar
Maximum 10 145 9.8 142 96 - 325 5.8 - 19.5 203 - 689

Minimum 5 72 5 72 104 - 485 6.2 - 29.1 220 - 1028


GA 132 VSD+ -
Nominal 7 101 7 101 101 - 463 6.1 - 27.8 214 - 981 132 77 2500 5512 2950 6504
8.5 bar
Maximum 8.5 123 8.3 120 100 - 427 6.0 - 25.6 212 - 905

Minimum 6 87 6 87 102 - 402 6.1 - 24.1 216 - 852


GA 132 VSD+ -
Nominal 9.5 138 9.5 138 97 - 396 5.8 - 23.8 206 - 839 132 77 2500 5512 2950 6504
10 bar
Maximum 10 145 9.8 142 96 - 391 5.8 - 23.5 203 - 828

Minimum 5 72 5 72 104 - 590 6.2 - 35.4 220 - 1250


GA 160 VSD+ -
Nominal 7 101 7 101 101 - 551 6.1 - 33.1 214 - 1168 160 78 2550 5622 3000 6614
8.5 bar
Maximum 8.5 123 8.3 120 100 - 511 6.0 - 30.7 212 - 1083

Minimum 6 87 6 87 102 - 492 6.1 - 29.5 216 - 1042


GA 160 VSD+ -
Nominal 9.5 138 9.5 138 97 - 480 5.8 - 28.8 206 - 1017 160 78 2550 5622 3000 6614
10 bar
Maximum 10 145 9.8 142 96 - 471 5.8 - 28.3 203 - 998

(1) Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009)
Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi)
- Intake air temperature 20°C (68°F)

(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).

Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.

( 3) Integrated dryer (FF): compressed air pressure dewpoint at dryer reference conditions 3°C (37°F).

FAD(1) is measured at the following working pressures:


Standard FF

8.5 bar version at 7 bar 7 bar

10 bar version at 9.5 bar 9.5 bar

Dimensions
L W H

mm mm mm

GA 110-160 VSD +
2500 1785 2020

GA 110-160 VSD (FF)


+
2900 1785 2020
Technical specifications
GA 110-160 VSD+ (60 Hz)
Maximum working pressure Capacity FAD (1) Installed Weight
Noise
motor
Standard / level (2)
TYPE Standard Full Feature (3) power Standard Full Feature (3)
Full Feature (3)
bar(e) psig bar(e) psig l/s m3/min cfm hp dB(A) kg lb kg lb

Minimum 5 72 5 72 104 - 407 6.2 - 24.4 220 - 862


GA 110 VSD+ -
Nominal 6.9 100 6.9 100 101 - 390 6.1 - 23.4 214 - 826 150 78 2400 5291 2800 6173
125 psi
Maximum 9.1 132 8.9 129 97 - 343 5.8 - 20.6 206 - 727

Minimum 6 87 6 87 102 - 405 6.1 - 24.3 216 - 858


GA 110 VSD+ -
Nominal 10.4 151 10.4 151 96 - 315 5.8 - 18.9 203 - 667 150 78 2400 5291 2800 6173
150 psi
Maximum 10.9 158 10.7 155 95 - 309 5.7 - 18.5 201 - 655

Minimum 5 72 5 72 104 - 485 6.2 - 29.1 220 - 1028


GA 132 VSD+ -
Nominal 6.9 100 6.9 100 101 - 466 6.1 - 28.0 214 - 987 175 78 2500 5512 2950 6504
125 psi
Maximum 9.1 132 8.9 129 98 - 412 5.9 - 24.7 208 - 873

Minimum 6 87 6 87 102 - 402 6.1 - 24.1 216 - 852


GA 132 VSD+ -
Nominal 10.4 151 10.4 151 96 - 378 5.8 - 22.7 203 - 801 175 78 2500 5512 2950 6504
150 psi
Maximum 10.9 158 10.7 155 95 - 372 5.7 - 22.3 201 - 788

Minimum 5 72 5 72 104 - 590 6.2 - 35.4 220 - 1250


GA 160 VSD+ -
Nominal 6.9 100 6.9 100 101 - 555 6.1 - 33.3 214 - 1176 215 78 2550 5622 3000 6614
125 psi
Maximum 9.1 132 8.9 129 98 - 495 5.9 - 29.7 208 - 1049

Minimum 6 87 6 87 102 - 492 6.1 - 29.5 216 - 1042


GA 160 VSD+ -
Nominal 10.4 151 10.4 151 96 - 456 5.8 - 27.4 203 - 966 215 78 2550 5622 3000 6614
150 psi
Maximum 10.9 158 10.7 155 95 - 449 5.7 - 26.9 201 - 951

(1) Unit performance measured according to ISO 1217, Annex C and E, Edition 4 (2009)
Reference conditions:
Absolute inlet pressure 1 bar (14.5 psi)
Intake air temperature 20°C (68°F)

(2) A-weighted emission sound pressure level at the work station, Lp WSA (re 20 μPa) dB (with uncertainty 3 dB).

Values determined according to noise level test code ISO 2151 and noise measurement standard ISO 9614.
Pressure dew point of integrated refrigerant dryer at reference conditions: 2°C to 3°C (36°F to 37°F)

( 3) Integrated dryer: Compressed air pressure dewpoint at dryer reference conditions 3°C (37°F)

FAD(1) is measured at the following working pressures:


Standard FF

5.5 bar version at 5 bar 5 bar

7.5 bar version at 7 bar 7 bar

8.5 bar version at 8 bar 8 bar

10 bar version at 9.5 bar 9.5 bar

Dimensions
L W H

mm mm mm

GA 90 - 160
+
2500 1785 2020

GA 90 - 160 (FF)
+
2900 1785 2020
COMMITTED TO SUSTAINABLE PRODUCTIVITY
We stand by our responsibilities towards our customers, towards the
environment and the people around us. We make performance stand
the test of time. This is what we call – Sustainable Productivity.

www.atlascopco.com

2935 0712 00 © 2018, Atlas Copco Airpower NV, Belgium. All rights reserved. Designs and specifications are subject to change without notice or obligation. Read all safety
instructions in the manual before usage.

24