You are on page 1of 31

Since 2005, Fire Alarm and Suppression

2022
System Manufacturer & Complete
Solution Provider.

LPCB Conventional
Fire Alarm Control System
AW-CFP2166

LPCB Approved Addressable Addressable Fire Alarm Centralized Monitoring


Fire Alarm Control System Control System Emergency Luminaire
AW-FP300 AW-FP100 System
Contents

01 Company Profile ATEX Approved Explosion-Proof Fire Alarm


22-26 Products

LPCB Approved Addressable Fire Alarm


02-04 27-30 Fire Linear Heat Cable
Control System

05-09 Addressable Fire Alarm Control System 31 Voice Evacuation Control Panel and Speakers

ASENWARE Global Fire Alarm Graphic


10 32 Addressable Fire Telephone System
Monitoring System

Centralized Monitoring Emergency Luminaire


11-16 LPCB Conventional Fire Alarm Control System 33-34 System

17-18 Wireless Conventional Fire Alarm System 35-36 Detector tester Series

19-20 Aspirating Smoke Detection System 37-39 Gas Suppression Release Control System

21 Weather Proof Fire Alarm Devices 40 Gas Fire Suppression system


Contents

41 Packaged Fire Pump System 52 Sprinkler Series

42-46 Water Based Fire Products

47-48 ASTM A53 Seamless Steel


Pipe & Fittings

49 Foam Fire Extinguishing System

Fire Hose Rack & Reel


50

51 Hose Accessories & Fire Blanket


Company Profile LPCB Approved Addressable Fire Alarm Control System

We focus on international standard and certificate fire safety products, until now we already got LPCB, TUV,
BSI, Intertek CE, Bomba ,ATEX certificates for our different products.

We support to design the projects based on NFPA and other international standards. All projects are designed
and verified by highly skilled engineering team. Moreover, we support our customers at site in different
countries for commissioning and other necessar y supports for the completion and submittal of the projects.

1 2
LPCB Approved Addressable Fire Alarm Control System LPCB Approved Addressable Fire Alarm Control System

AW-FP300 Fire Alarm Control Panel

1-8 Loop Fire Panel

The purpose of the AW-FP300 Fire Alarm


Control Panel (FACP) is to monitor input signals,
give indications and possibly activate outputs
as programmed. It is designed to comply with
EN 54-2 and EN 54-4 with qualities of simple
installation, operation and easy Adderssable Smoke
maintenance.The AW-FP300 panel is an Addressable Smoke Detector Addressable Heat Detector and Heat Combined Detector
addressable fire detection panel with 1 loop of AW-D301 AW-D302 AW-D303
324 addressable points and expansion
capabilities. It is compatible with other
peripherals made by ASENWARE with its own
protocol.

Addressable Gas Detector Addressable Sounder Beacon AW-D306 Addressable Manual Call Point
AW-AGD2188 Conventional Sounder Beacon AW-D316 AW-D305
The AW-FP300 single loop 32 zone fire alarm control panel offers the following features Signal Loop 24V(18V~28V)
Operating Voltage
Power 24VDC(20VDC~28VDC)
Up to 324 addresses in one loop, 648 addresses in two loops Standby Current Loop≤0.8mA ; Power≤2mA
Action Current Loop≤5mA ; Power ≤15mA
An easy to read,4.3" color screen LCD with a resolution of 480x272 Output Capacity 1A@DC30V
Input Mode Setting NC or NO input mode can be set
Zone indication and control panel (ZCP)for 32 zones gives a quick indication of the by the jumper JP4.
location of an alarm or fault

Record capacity of 1000 historical events for each of historical fire,historical fault
and historical operation

CAN bus for interconnection of up to 20 FACPs and RS-485 for connection with
up to 30 fire indicating panels per FACP

Coder Loop Isolator Addressable I/O Module Addressable Repeater


AW-CODER2188 AW-D314 AW-D319 AW-RP2188

A device for giving specific ID to all the


addressable accessories which need to be
configured with AW-FP300 control panel.

Addressable Strobe Sounder Base


AW-D320
4G GSM Module
AW-GSM200

3 4
Addressable Fire Alarm Control System Addressable Fire Alarm Control System

AW-FP100 Fire Alarm Control Panel

1-8 Loop Fire Panel


Asenware AW-FP100 Series Fire Alarm Control Panel are intelligent
panels which are designed to make it suitable for most of
applications. The user friendly functionality makes it suitable to
program and configure the devices. 7 " touchscreen display shows
the information for fire alarm, trouble, super visor y and other
related information all the time.
AW-FP100 series can be configured with just a few devices for small
building applications, or for a large area or high-rise application.
Simply add additional equipment to suit the application like
detectors,modules and other compatible devices. It is supplied with
cabinet of IP 30 rating (standard). This panel fully comply with the
requirement of EN 54-2 and EN 54-4.

The AW-FP100 fire alarm control panel offers the following features

7" Touchscreen LCD Colored Display

250 intelligent detectors or modules for one loop circuit

Up to 8 Loop Cards can be installed and configured

2-Wire cable for all addressable devices

Network Available Options: GSM/IP/Cloud/Modbus

Graphic remote monitor access system

Programmer Addressable Detector 4G GSM Module


AW-FP100GSM-4G
AW-PR101 Strobe Sounder Base
AW-D120

5 6
Addressable Fire Alarm Control System Addressable Fire Alarm Control System

CAN Bus Transmitter


AW-D122

This CAN Bus Transmitter AW-D122 is designed for extend the distance of
CAN Bus communication. It is suggested to be installed over each 400
meters.

Addressable Smoke Detector Addressable Heat Detector Addressable Smoke and Heat Detector
AW-D101 AW-D102 AW-D103

Addressable LPG Gas Detector


AW-D132A

The gas detector is designed for single station use or for connecting to fire
alarm or security alarm panel. Small and compact, the design and color
makes it ideal for use in the home, small commercial properties, and
recreational vehicles. It is intended to detect leakage of natural gas
(methane gas),town gas, and bottled gas (propane gas) The gas detector
can be mounted high (for methane gas) or low (for propane (LPG) gas). It is
equipped with a sturdy mounting bracket for quick , easy and safe
installation.

Features
Detect all sorts of combustible gases, natural gas (methane), bottled gas (propane),LPG(Liquefied petroleum Gas),
Wireless Batter y Heat Detector Wireless Smoke and Heat Detector Wireless Batter y Smoke Detector LNG (Liquefied natural gas), including town gas.
AW-STD606A AW-SST606A AW-SSD606A
Easy to install, mounting bracket included.

High quality durable sensor.

Self diagnostic function by MCU intelligent software

Excellent reliability & High stability.

Ideal for all kitchens.

Addressable Alarm Bell Addressable Strobe Sounder Addressable Manual Call Point
AW-D109 AW-D106 AW-D135A
Addressable Monitor Addressable Super visor y Addressable Control Addressable Relay Isolator Module
Module Module Module Module
AW-D110 AW-D111 AW-D112 AW-D113 AW-D114

7 8
Addressable Fire Alarm Control System ASENWARE Global Fire Alarm Graphic Monitoring System

Addressable Annunciator
AW-D116

Features
Three lines of 40 character each LCD

LED indication for alarm, fault and super visor y

Push buttons to acknowledge the silence

Lamp test from key switch

Addressable Annunciator Board


AW-D117&AW-D118

Features
24 Zones Addressable
AW-D117
Annunciator LED Main Board

AW-D118 24 Zones Addressable


Annunciator LED Extension Board
Features
Supports LAN and CLOUD mode

Multi Level Management

Automatically send Emails & SMS to the building managers, engineers or concerned person for fire or fault events
Addressable Power Transmitter
CLOUD mode can monitor all running panels around the world
AW-D121
User-friendly,easy to operate and manage to operate and manage
Addressable Power Transmitter, an intelligent power supply,
which is designed to provide auxiliar y power when there is not
Aesthetic design while maintaining the simplicity in drag and drop feature for devices to the layout
enough power from panel to devices.

Features
Addressable

5A@24VDC output

EN54-4 standard

Include batter y charger

12V2.3AH*2 batteries optional

9 10
LPCB Conventional Fire Alarm Control System LPCB Conventional Fire Alarm Control System

AW-CFP2166 Conventional Fire Alarm Control Panel

1-32 Zooe Fire Alarm Panel

Conventional Photo-Electric Conventional Photo-Electric Standalone Smoke Detector


Smoke Detector Smoke Detector AW-D611
AW-CSD381 AW-CSD311

Main Voltage
M a in V o lta g e Zone 24V / 12V Main Voltage
M a in V o lta g e Zone 24V / 12V Operating voltage: 9VDC
M a in V o lta g e

Monitoring Status ≤120uA Monitoring Status ≤120uA Monitoring Status ≤8uA

Alarm Status ≤15mA Alarm Status ≤15mA Alarm Status ≤20mA

Alarm Sensitivity 0.1 to 0.15 dB/m Alarm Sensitivity 0.18~0.3 dB/m Alarm Sensitivity 0.18~0.26 dB/m

Standalone Batter y Heat Detector Standalone Batter y Standalone Batter y


AW-STD606D Smoke Detector Smoke & Heat Detector
AW-SSD606D AW-SST606D

Conventional Conventional Conventional


Fire Alarm Control Panel Fire Alarm Control Panel Fire Alarm Control Panel
2/4 Zone 6/8 Zone 12/16/ 32 Zone
AW-CFP2166-2 AW-CFP2166-6 AW-CFP2166-12
AW-CFP2166-4 AW-CFP2166-8 AW-CFP2166-16
AW-CFP2166-32

Features
AW-CFP2166 series conventional fire alarm panel is designed based on
EN54 part 2&4 standard.
Rate of Rise Temp Heat Detector Rate of Rise Temp Heat Detector
It is modularized design, the panel can expand from 1 zone to 32 zones easily. ROR/A2R ROR/A2R
AW-CTD382 AW-CTD321
It has 2 levels control mode by a lock .
Main Voltage
M a in V o lta g e Zone 12V/24V DC Main Voltage
M a in V o lta g e 9-28V DC

It has an optional GSM module for fire alarm by SMS. Monitoring Status ≤120uA Monitoring Status ≤120uA

Alarm Status ≤15mA Alarm Status ≤15mA

Weight about 100g Weight about 100g

11 12
LPCB Conventional Fire Alarm Control System LPCB Conventional Fire Alarm Control System

Standalone LPG GAS Detector Conventional UV Flame Detector Conventional 4 Wire CO detector Conventional Sounder Beacon Repeater Entrance LED Indicator
AW-CGD2166 AW-FD602-UV AW-D125C AW-D316 AW-CRP2166 AW-EL102
Standalone batter y CO detector
AW-D125S

6 Inch Fire Bell 8 Inch Fire Alarm Bell


Horn Strobe AW-CBL2166-6 AW-CBL2166-8
Conventional Manual Call Point Conventional Fire Strobe Sounder
AW-D135C AW-CSS2166-2
AW-CSS2166-3

Duct Smoke Detector


AW-CSD313

Horn Strobe Horn Strobe


AW-CSS2166-4 AW-CSS2166-5

4G GSM Module Standalone LPG Gas Detector


AW-GSM200 AW-D132

4 wire Standalone LPG Gas Detector


AW-D132C

13 14
Conventional Fire Alarm Control System Wireless Conventional Fire Alarm System

Beam Smoke Detector


AW-BK901

The AW-BK901 infrared linear reflex beam


smoke detector, is being designed for fire
prevention in the open area, is used with the
fire alarm control panel.The detector is made
up of the combination unit of the emitter and
the receiver as well as the reflecting mirror
The signal issued by the emitter enters into the
receiver after reflection by the reflector.

Conventional Fire Alarm


Control Panel
AW-CFP2166-2W/4W

Operating Environment

Power supply voltage: 16V-28VDC Alarm current <33mA

Overall power consumption: <3W Debug current <20mA

Monitoring current 12mA

Use conditions:Temperature:-10°C~+50°℃ ,Relative humidity <95%

Protective area:The maximum protective area of the detector is


1400 ㎡14X100-1400 m) and the maximum width is 14m.

AW-BK901-20 20meters with 1 reflector

AW-BK901-40 40meters with 1 reflector

AW-BK901-70 70meters with 4 reflector


Wireless Batter y Heat Detector Wireless Batter y Smoke Detector Wireless Smoke and Heat Detector
AW-BK901-100 100meters with 4 reflectors AW-SSD606A
AW-STD606A AW-SST606A

Addressable Strobe Sounder Wireless Manual Call Point Programm address for each device
AW-D106A AW-D135A AW-PR101

15 16
Wireless Conventional and Addressable Fire Alarm System Wireless Conventional and Addressable Fire Alarm System

Conventional Fire Alarm Wireless Addressable Wireless Addressable Wireless Addressable Wireless Addressable
Control Panel Smoke Detector Heat Detector Smoke Detector Heat Detector
AW-CFP2166-2W/4W AW-D603 AW-D604 AW-D603 AW-D604

Wireless LoRa 433MHZ to


WIFI Transmitter
AW-D139

Addressable Strobe Sounder


with Wireless Transmitter
AW-D106A
Wireless Addressable Wireless Addressable
Smoke and Heat Detector Manual Call Point Max 20
Max 20 AW-D605 AW-D135A wireless devices Wireless Addressable Wireless Addressable
wireless devices in one zone Smoke and Heat Detector Manual Call Point
AW-D605 AW-D135A
in one zone

Wireless Addressable
Smoke Detector
Wired & Wireless Addressable Strobe Sounder AW-D603
Fire Alarm Control Panel with Wireless Transmitter
AW-FP214 AW-M601
Standalone Wireless Batter y
Wifi Smoke Detector
AW-D611W

Max 20
wireless devices
Wireless Addressable Wireless Addressable Wireless Addressable in one zone
Heat Detector Smoke and Heat Detector Manual Call Point
AW-D604 AW-D605 AW-D135A

17 18
Aspirating Smoke Detection System Aspirating Smoke Detection System

Combustion analysis:
Temp Phisical Change
Phisical and Chemical Change

Thermal
Stable Decomposition
Condition

Incipient Stage
of Fire Time

Fire detection
Aspirating Smoke Detection System Aspirating Smoke Detection System
with Cloud
AW-AS200 AW-AS100 Chamber
Principle

Advantages
Earlier detection with high sensitivity

Immunity to false alarms

Advanced Al applications
Cost effective maintenance solution

Features
Cloud Chamber principle

7 inch color touch screen

More than 10 years ser vice life


Automatic cleaning function
Convenient maintenance solution
Versitile networking solutions

19 20
Weather Proof Fire Alarm Devices ATEX Approved Explosion-Proof Fire Alarm Products

Explosion-Proof Infrared
Fire Alarm Weather Proof Series
Beam Smoke Detector
AW-BK901EX
Features

Weather proof The AW-BK902E type explosion-proof infrared


beam smoke detector is a non-coded reflective
Dustproof linear infrared beam smoke detector. The
detector must be used in conjunction with the
Good sealing reflector, but one or four reflectors should be
used according to the installation distance
Factor y direct sales
between the two devices.
The detector has advanced functions and
Quality Assurance powerful analysis and judgment capabilities.
Through our original program, it can
automatically complete system debugging,
compensation for changes in the external
environment, fire alarm and fault judgment, and
the output status is displayed through indicator
lights and terminals.

Smoke detector waterproof base

Features Features

Diameter : 116mm Newest and reasonable structure design

Inner diameter : 112.5mm Sensitive adjustment, accurate positioning

Aperture: 34mm Good performance, easy to install

Height: 64mm
Horn Strobe
AW-CSS2166-4W

Applicable Products
Suitable for most models
of smoke detector

Applicable Products

Features

Protection level:IP67 Explosion-proof fire alarm bell Explosion-proof safety barrier Explosion-proof strobe sounder
AW-CBL2166EX AW-D137EX AW-CSS2168EX
Function:Dust-proof;Rain-proof
Main Voltage 24 VDC Main Voltage DC 24V Main Voltage DC 24V
Operating current Alarm≤25 mA Operating current Alarm≤25 mA Operating current Alarm≤250 mA
L*W*H:120*190*110mm
Ex-Atex Protection Level Exd II CT6 Gb Ex-Atex Protection Level Exd II CT6 Gb Ex-Atex Protection Level Exd II CT6 Gb
Size (L*W*H) 260* 152* 80mm Size (L*W*H) 260* 152* 80mm Size (L*W*H) 260* 152* 80mm

Conventional
Weather proof Box Manual Call Point
AW-D135C

21 22
ATEX Approved Explosion-Proof Fire Alarm Products ATEX Approved Explosion-Proof Fire Alarm Products

Explosion-Proof Gas Detector


AW-D104EX

AW-EXD104 intelligent digital readout transmitter is a two-wire system and meet the international standard digital transmitter
which can convert the gas concentrations into standard 4-20mA current signal. It"s suitable for the industrial LED to display and
the sensor easy to use and plug and play. AW-EXD104 have many advantages: high performance, stable and reliable operation,
easy to install and maintain, and it can measure full range of gas and so on, which can meet the high demand in the industrial
site safety monitoring. It widely used in petroleum, chemical, engineering,metallurgy, petrochemical, gas transmission and
distribution, biochemical, medicine,
water treatment and other industries.

Explosion-proof optical Explosion-proof heat detector Explosion-proof


smoke detector AW-CTD382EX smoke and heat combined detector
AW-CSD381EX AW-CSH831EX

AW-CSD381EX AW-CTD382EX AW-CSH831EX

Explosion-proof weather-proof Explosion-proof manual call point Explosion-proof fire strobe


strobe sounder AW-D135EX AW-CSS2166EX
AW-CSS2167EX

AW-CSS2167EX AW-D135EX AW-CSS2166EX

23 24
ATEX Approved Explosion-Proof Flame Detector ATEX Approved Explosion-Proof Flame Detector

Explosion-proof ultraviolet Explosion-proof Ultraviolet Explosion-proof Ultraviolet & Infrared Explosion-proof Infrared 3
& infrared 3 flame detector Flame Detector Combined Flame Detector Flame Detector

AW-FD704EX-UVIR3 AW-FD706EX-UV AW-FD707EX-UVIR2 AW-FD708EX-IR3

Spectrum Range UV(185-260nm),IR (3.8um/4.3um/5.0um) UV 185-260nm Spectrum Range UV 185-260nm UV 185-260nm

Detection Angle 120° 120° Detection Angle 120° 120°

Sensitivity Level Grade l Grade l Sensitivity Level Grade l Grade l

24VDC(18-30VDC) 24VDC(18-30VDC) 18 to 30VDC Volts 18 to 30VDC Volts

Ex-Atex Protection Level Exd II 2 G Ex d IIC T6 Gb Exd II 2 G Ex d IIC T6 Gb Ex-Atex Protection Level Exd II 2 G Ex d IIC T6 Gb Exd II 2 G Ex d IIC T6 Gb

IP66/IP67 IP66/IP67 IP66/IP67 IP66/IP67

Temperature range:-40℃ ~70℃ Temperature range:-40℃ ~70℃


Temperature range:-40℃ ~85℃
Storage temperature range:-40 ~85°F Storage temperature range:-40 ~85°F Temperature range:-40℃ ~70℃
Humidity: 0~96%RH (non-condensing
Humidity: 0~96%RH (non-condensing Humidity: 0~96%RH (non-condensing (-40 ~158°F)
can withstand 100% condensing humidity
can withstand 100% condensing humidity can withstand 100% condensing humidity Humidity: 0~96%RH (non-condensing)
for a short time)
for a short time) for a short time)

1 x 3/4NPT, M25*1.5, G3/4


Electrical Interface 1x3/4NPT, M25*1.5,G3/4, optional 1x3/4NPT, M25*1.5,G3/4, optional Electrical Interface 1x3/4NPT, M25*1.5,G3/4, optional (Adapters can becustomized
according to requirements)

120mm* 95mm* 85mm 120mm* 95mm* 85mm 120mm* 95mm* 85mm 120mm* 95mm* 85mm

about 0.7kg about 0.7kg about 0.7kg about 0.7kg

25 26
Fire Linear Heat Cable Fire Linear Heat Cable

Fire heat cable

Conventional Fire Alarm Interface Module End of line Module


Control Panel AW-D401 AW-D402
AW-CFP2166-4C

Lineair Heat Cable Model AW-D4068 AW-D4088 AW-D4105 AW-D4138 AW-D4180


(Conventional (Conventional (Conventional (Conventional (Conventional
Type 68°C) Type 88°C) Type 105°C) Type 138°C) Type 180°C)
Features

Line coverage...continuous sensitivity.


AW-D4068-P AW-D4088-P AW-D4105-P AW-D4138-P AW-D4180-P
(CR/OD Type 68°C) (CR/OD Type 88°C) (CR/OD Type 105°C) (CR/OD Type 138°C) (CR/OD Type 180°C)
Six alarm temperature ratings.

Withstands severe environmental conditions.


AW-D4068-E AW-D4088-E AW-D40105-E AW-D4138-E AW-D4180-E
Approved for hazardous locations. (EP Type 68°C) (EP Type 88°C) (EP Type 105°C) (EP Type 138°C) (EP Type 180°C)

Easy to install, test, and splice. Parameter

Easy to install, test, and splice. Alarm 68°C 88°C 105°C 138°C 180°C
Temperature
Compatible with other initiation devices
on same circuit.

Ambient
45°C 60°C 75°C 93°C 121°C
temperature (Max)

-55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type
Ambient
Temperature (Min)
-40°C for -40°C for -40°C for -40°C for -40°C for
Conventional Conventional Conventional Conventional Conventional
and EP Type and EP Type and EP Type and EP Type and EP Type

Storage UP TO 45°C UP TO 45°C UP TO 70°C UP TO 70°C UP TO 105°C


Temperature

Alarm Deviation ±3℃ ±5℃ ±5℃ ±5℃ ±8℃

Dimensions 90mm×85mm×52mm Operating Voltage No Electronics


Operating environment Temperature:-45℃--+60℃ Operating environment Temperature:-45℃--+60℃
Relative humidity 95% Relative humidity 95% Alarm Response 10 (Max) 10 (Max) 15 (Max) 20 (Max) 20 (Max)
IP Rating IP66 IP Rating IP66 Time (s)

27 28
Fire Linear Heat Cable Fire Linear Heat Cable

Fire Proof Cable


Conductor : 1/1.63 BC

Features Inner wire:brown,blue(UL 105°PVC)

Oxygen-free Copper Drain:1/0.4 Tinned Copper

Wrapping:aluminum foil
High temperature resistance
Outer jacket: Red (UL 105° PVC-55P)
Halogen and smoke free

Quality Assurance

Conductor : 1/1. 02Bare Copper Conductor : 1/1.29Bare Copper


Core: Red. Black (UL105° PVC-35P) Core: Red. Black (UL105° PVC-35P) AW-FPLR2X2.0
Model
Drain: 1/0. 4Tinned Copper Drain: 1/0. 4Tinned Copper
Wrap:aluminum foil Wrap:aluminum foil
Outer jacket: Red (UL 105° PVC-55P) Outer jacket: Red (UL 105° PVC-55P)
Conductor 1/1.63 solid bare copper

Max conductor resistant Ω/KM (20℃) 8.45

Insulation thickness 0.51 mm


Min insulation thickness 0.46 mm

2.2±0.1
Inner wire brown.blue(flame retardant PVC)

6.0±0.3 Wire numbers 2 core


Drain wire 0.4mm tinned copper
Wrapping Al-foil

Model AW-FPLR2X1.0 Model AW-FPLR2X1.5 Jacket red (flame retardant PVC)


OD 6.8±0.3 mm
Conductor 1/1.02 solid bare copper Conductor 1/1.29 solid bare copper
Jacket thickness 0.74 mm
Max conductor resistant Max conductor resistant
21.4 13.5 Min jacket thickness 0.62 mm
Ω/KM (20℃) Ω/KM (20℃)
Insulation thickness 0.38 mm Insulation thickness 0.44 mm Rated temperature 105℃
Min insulation thickness 0.33 mm Min insulation thickness 0.39 mm Rated voltage 300V
Inner wire brown.blue Inner wire brown.blue
Fame retardant rating Vw-1
(flame retardant PVC) (flame retardant PVC)
Wire numbers 2 core Wire numbers 2 core Application fire alarm systems
Drain wire 0.4mm tinned copper Drain wire 0.4mm tinned copper
Wrapping Al-foil Wrapping Al-foil
Jacket red (flame retardant PVC) Jacket red (flame retardant PVC)
OD 5.2±0.3 mm OD 5.8±0.3 mm
Jacket thickness 0.58 mm Jacket thickness 0.64 mm
Min jacket thickness 0.46 mm Min jacket thickness 0.52 mm
Rated temperature 105℃ Rated temperature 105℃
Rated voltage 300V Rated voltage 300V
Fame retardant rating Vw-1 Fame retardant rating Vw-1
Application fire alarm systems Application fire alarm systems

29 30
Voice Evacuation Control Panel and Speakers Addressable Fire Telephone System

Voice Evacuation Control Panel Fire Fighting Telephone System


AW-VP350 AW-FT599

AW-VP350 Voice Evacuation Control Panel and The fire fighting telephone system is suitable for
speakers is a standalone public audio system for communication and dispatching during any fire
emergency evacuation. When get alarm input or emergency in the building. In case of fire alarm
from other fire alarm system or security alarm at the application site, the site personnel can call
system, it can play the pre-recorded audio track the host through extension and contact the
to the speakers automatically. It also can control center in time. The operator in the
broadcast the microphone real time sound, or control center can also call the extension at the
other line in sound. It also support RS485 site through the host to know the situation on
communication with ASENWARE AW-FP300 the site.
series addressable fire alarm control panel.

Features Features

Maximum power output: 350Watt. With the two-bus technology, the power supply and communication are compatible on two buses, and are not divided
into the positive and the negative, convenient for debugging
Speaker driving mode: constant voltage.
It has perfect detection measures, which can detect the short circuit and open circuit of the bus, and make sound and
Evacuate message up to 1 minute. light alarm

The anti-interference performance of hardware and software allows for the adaptability tovarious complex environments.
Background audio: USB2.0
The voice is subject to differential transmission on the bus, with strong anti-interference capability.
Complies with EN54 part 16.
The application of silica gel button presents a beautiful appearance, good hand feeling and long ser vice life.
Network function (work with AW-FP300 series addressable fire alarm control panel)
The host and extension can call each other and make full-duplex call, and the host can communicate with three
Maximum 15 pcs AW-VP350 can be connected with 1 pcs AW-FP300 addressable fire alarm control panel. extension telephones at the same time.
It has the function of recording and displaying the calling and answering time, and can quer y 120 records of calling and
2.6.2 Each AW-VP350 panel can be programmed to maximum 20 channels and controlled by AW-FP300 addressable response time between the host and the extension.
fire alarm control panel
The recording is subject to circular coverage, first-in-first-out mode and automatic recording is enabled during a call.

conventional telephone system


AW-FTP2008(8 zones)
AW-FTP2016 (16 zones)

AW-FTP2008 (8 zones), AW-FTP2016 (16 zones) fire telephone panel is a new fire
special communications equipment,when the fire accident, which provides a
convenient means of communication, the fire control and alarm systems
necessar y communications products. Wall-mounted structure is easy to install,
Ceiling Speaker Ceiling Speaker Wall Mounted Speaker 15W Water Proof Speaker 30W Water Proof Speaker suitable for small systems.
AW-SP01 AW-SP02 AW-SP03 AW-SP04 AW-SP05

Addressable Conventional Conventional Addressable


Fire Telephone Jack Fire Telephone Handset Fire Telephone Jack Fire Telephone Handset
AW-D501 AW-D502 AW-D504 AW-D505

31 32
Centralized Monitoring Emergency Luminaire System Centralized Monitoring Emergency Luminaire System

Emergency Luminaire System

This control system is designed for managing,


testing, monitoring and controlling emergency
lighting which is mounted dispersedly.

Features

Humanized Ul control by 7 inch colorful LCD

Easy operating

Convenient using

Communicated by PLC

Easy Mounting

Low maintenance cost

Features

Maximum 500 lightings;

Simultaneously and remotely control one or more lightings;

More than 500 histor y events record;

Up to 16-way non-source emergency input signs testing;

Up to 16 lighting zones;

Up to 16 testing group;

Detecting batter y fault, LED source fault, AC fault and communication fault for single emergency lighting;
220V-240VAC 50/60Hz
AW- EL203 Nickel-cadmium 3.6V
<24 hours

220VAC 50/60Hz
1800lm
Twin Lamp AW-EL208
Emergency Light <24 h

220VAC 50/60Hz
≥130lm
LED Lamp AW-EL103
The installation can be performed per below figure in actual condition.Exit Lights and Emergency lighting can be Emergency Light <24h
connected to directly from the panel and power would be supplied from the panel itself. Panel has two sources, one is AC
mains and another one is 24 Volts batter y (or two 12V batteries).

33 34
Detector tester Series Detector tester Series

Smoke&Heat Detector
Heat detector tester 2in1 Tester
AW-D202 AW-D206

Smoke & Heat Detector Disassembly tool


AW-D208

Accessor y list

Flame simulator
Smoke detector tester AW-D204 Smoke & Heat Detector
AW-D201 Disassembly tool
AW-D208

Flame simulator
AW-D204
Features

Batter y voltage:DC7.4V.2200MA/H

Charger output:DC8.4V, 1000MA


Smoke detector tester Heat detector tester
The total length of the tester :2.5m
AW-D201 AW-D202
Materials of the tester :aluminum
Features Features
Materials of the connecting rod:stainless steel
Length 1.6 meter x Dia.32mm Heating Element :220V/100W or 110V/100W
Materials of package box:aluminum
Light Weight Aluminium pole Length 1.75meter x Dia.32mm Light weight
Infrared waveband scope of (0.5 u m-5.5 u m)
Aluminum Pole
Triggering mechanism
Cable Length 30meter ultraviolet waveband scope of (185nm-255nm)
Aluminium case with lock
Aluminum case with lock
Smoke & Heat Detector 2inl Tester
AW-D206

35 36
Gas Extinguishing System Gas Extinguishing Release Control System

Fire Bell
AW-CBL2166-6

Mode Switch
AW-GD203

Gas Extinguishing Release Control System


AW-GEC2169

Sequence Starter
Manual Release Station Abort Switch
AW-GD201 AW-GD202 AW-GD205

AW-FMEV80

Fire Extinguishing System CO 2 Extinguishing System Packaged Fire Pump


Fm200/FK-5-1-12 System

FM200

37 38
Gas Extinguishing Release Control System FM-200 Gas Extinguishing System

AW-GEC2169 Extinguishing control panel


AW-GEC2169 extinguishing control panel is
designed in compliance with the requirements
of European standards of EN54-2, EN54-4 and
EN12094-1. This panel can be used in
FM200,CO2, IG541, N1230 and other gas fire
extinguishing systems.

Features

Alarm input: four alarm zones signal input, each zone can connect up to 16 detectors.

EM valve output: control the output of electromagnetic valve.

Panel outputs: circuit fault output / alarm output/ fire extinguishing signal output/24VDC output other parts working
condition.

Power output: resettable 24VDC output, 200mA current-limited protection.

Automatic power shift: 220VAC power and standby batter y power can be switched automatically.

GSM module (optional): GSM module allows users to receive alarm information by SMS.

Asenware Clean Agent Fire extinguishing systems utilizes FM-200 as extinguishing gas. Asenware FM-200 systems are
available as Engineered and Pre-Engineered Systems (Cabinet System).

Cabinet Type Manifold Type

39 40
Packaged Fire Pump System Water Based Fire Products

Packaged Fire Pump system Fire sprinkler system


Packaged Fire Pump system, can provide the complete skid for Fire Pump ser vice.Systems include the pump, driver, The fire sprinkler system is an active fire protection measure, consisting of a water supply system, providing adequate
controller and jockey pump all mounted on a common base.Controller is pre-wired to the drivers. pressure and flow rate to a water distribution piping system, onto which fire sprinklers are connected. Although
historically only used in factories and large commercial buildings, systems for home and small building are now
available at a cost-effective price. Fire sprinkler systems are extensively used worldwide with over 40 million sprinkler
heads fitted each year. In buildings completely protected by fire sprinkler systems,over 99% of fires were controlled by
fire sprinklers alone.

Features

Full Assembly (Electric, Diesel and Jockey Pumps)

Common Base

Suitable Suction and Discharge Piping

Includes Check Valve, Isolation Valves and Pressure Gauges

Diesel Fuel Tank Mounting (optional ) and Batter y Connection

Suitable Pressure Tank

Pre -Assembled Controller

Automatically run and stop jockey pump, electrical motor pump and diesel pump.

Automatically charge the batter y.

Special water flow path design for high efficiency.

Full test with pressure guage and flow meter at same time.

41 42
Water Based Fire Products Water Based Fire Products

boundar y dimension unit:mm


Nominal pressure(MPa)
DN L HA HC

50 178 322 374

65 190 332 398

80 203 350 429


1.6MPa
100 229 420 524

125 254 581 721


2 Way Fire Hydrant 3 Way Fire Hydrant Flange Type Landing Valve
150 267 581 736
Gate Valve
DN50-DN200 200 292 736 942
Outlet Size 2 x2.5" Outlet Size 1 x4" & 2 x2.5" Outlet Size 2.5"
Inlet Size 4" Inlet Size 6" Inlet Size 2.5"
Material Cast Iron Material Cast Iron Material Brass
Working Pressure 15 Bar Working Pressure 15 Bar Working Pressure 1.6 Mpa

Nominal pressure(MPa) DN H1 H2 H3 D1 D2 L1

50 70 130 68 120 95 43

65 76 143 68 136 109 46

80 86 155 68 160 124 46


1.6MPa
100 104 170 68 182 153 52

125 118 190 68 215 179 56

150 132 210 68 238 206 56


Butterfly Valve 200 167 243 85 295 264 60
DN 50-DN 200

Thread Type Landing Valve 2 Way Breeching Inlet 4 Way Breeching Inlet

Nominal pressure(MPa) Nominal PN16


L D D1 H H1
diameter DN (mm)
Outlet Size 2.5" Outlet Size 2x 2.5" Outlet Size 4x 2.5"
Inlet Size 2.5" Inlet Size 4" Inlet Size 6" 50 240 160 125 265 210

Material Brass Material Cast Iron Material Cast Iron


65 240 180 145 310 215
Working Pressure 1.6 Mpa Working Pressure 10 Bar Working Pressure 10 Bar
1.6MPa
80 292 195 160 350 245

100 325 215 180 460 305

125 340 245 210 520 365


Pressure Reducing Valve
DN 50-DN 200 150 403 280 240 570 415

435 335 295 695 510


200

43 44
Water Based Fire Products Water Based Fire Products

L H
Nominal pressure(MPa)
DN spiral flange spiral flange

65 225 135

80 280 175

100 300 195


1.6MPa
125 350 220

150 390 240

200 500 335


Boundar y dimension
(Y-type filter) Sight Glass Check Valve Pipe Fittings
DN65-DN200 DN12-DN32 DN 50-DN 200 Variable

Test pressure (MPa)


Applicable Operating
Nominal pressure(MPa)
medium Humidity
Shell Seal

Clean water
and sewage
1. 76 without ≤80℃
1.6MPa 2.4
impurities

Main Relief Valve


DN 50-DN 200 Flexible Coupling Flow Meter Air Vent
DN 50-DN 200 DN 50-DN 200 DN 50-DN 100

Nominal pressure(MPa) Installation Nominal Working Sensitivity


diameter pressure(Mрa) L/min

flange
DN25
1.6MPa ON50
DN65
Saddle type DN80
1.2 15<Q<37.5
DN100
DN125
welded DN150
DN200

Seamless Galvanized Steel Pipe


Flow Indicator ASTM A53
Silk mouth type
DN 25-DN 200

45 46
ASTM A53 seamless steel pipe ASTM A53 seamless steel pipe

A53 Chemical components


ASTM A53 seamless steel pipe
Chemical components
Seamless steel pipe (SMLS) is formed by drawing a solid billet over a piercing rod to create the hollow shell, without
Standard Trade Mark C Si Mn P S Cu Ni Mo Cr V
welding or seam. It is suitable for bending and cutting. The advantage of seamless steel is the ability of withstanding
higher pressure.ASTM A53 specification also covers seamless steel pipe. The pipe is intended for pressure and A ≤0.25 / ≤0.95 ≤0.05 ≤0.045 ≤0.40 ≤0.40 ≤0.15 ≤0.40 ≤0.08
mechanical applications and is also acceptable for ordinar y uses in oil, gas, steam, water and air lines. It is suitable for
ASTM A53
welding, bending and flanging. ≤0.30 / ≤1.2 ≤0.05 ≤0.045 ≤0.40 ≤0.40 ≤0.15 ≤0.40 ≤0.08
B

A53 Mechanical property

Standard: ASTM A53, Type S, Grade B Tensile strength (Mpa) Yield Strengt(Mpa) Elongation(%)
Dimension: Sch40 /Sch80 as ASME B36.10M
Application: Fire main pipe, fire pump pipe,
fire standpipe, fire sprinkler branch pipe , ≥330 ≥205 ≥29.5
Black and red seamless pipe is available
≥415 ≥240 ≥29.5

Pipe Fittings

Outside Diameter amd Wall Thickness(American Standard ANSI B36.10 B36.19M)

N o r minal Outside
P i p e Size Diameter Norminal Wall Thickness
Galvanized Steel Pipes Galvanized Steel Elbow 90° Galvanized Steel Elbow 90° Galvanized Steel Tee
N PS DN D SCH10s SCH10 SCH20 SCH30 SCH40 s STD SCH40 SCH60 S C H80 s XS S C H80 SCH100 S C H120 SCH104 SCH160 XXS (Welded Type) (Threaded Type) (Welded Type)

1/8 6 10.3 1.24 -- -- -- 1.73 1.73 1.73 -- 2.41 2.41 2.41 -- -- -- -- --


1/4 8 13.7 1.65 -- -- -- 2.24 2.24 2.24 -- 3.02 3.02 3.02 -- -- -- -- --
3/8 10 17.1 1.65 -- -- -- 2.31 2.31 2.31 -- 3.20 3.20 3.20 -- -- -- -- --
1/2 15 21.3 2.11 -- -- -- 2.77 2.77 2.77 -- 3.73 3.73 3.73 -- -- -- 4.78 7.47
3/4 20 26.7 2.11 -- -- -- 2.87 2.87 2.87 -- 3.91 3.91 3.91 -- -- -- 5.56 7.82
1 25 33.4 2.77 -- -- -- 3.38 3.38 3.38 -- 4.55 4.55 4.55 -- -- -- 6.35 9.09
1 1/4 32 42.2 2.77 -- -- -- 3.56 3.56 3.56 -- 4.85 4.85 4.85 -- -- -- 6.35 9.70
1 1/2 40 48.3 2.77 -- -- -- 3.68 3.68 3.68 -- 5.08 5.08 5.08 -- -- -- 7.14 10.15
2 50 60.3 2.77 -- -- -- 3.91 3.91 3.91 -- 5.54 5.54 5.54 -- -- -- 8.74 11.07
2 1/2 65 73.0 3.05 -- -- -- 5.16 5.16 5.16 -- 7.01 7.01 7.01 -- -- -- 9.53 14.02
3 80 88.9 3.05 -- -- -- 5.49 5.49 5.49 -- 7.62 7.62 7.62 -- -- -- 11.13 15.24
Galvanized Steel Galvanized Steel
3 1/2 90 101.6 3.05 -- -- -- 5.74 5.74 5.74 -- 8.08 8.08 8.08 -- -- -- -- -- Galvanized Steel Tee Galvanized Steel Cross Tee
Bell Reducer Bell Reducer
(Threaded Type) (Threaded Type)
4 100 114.3 3.05 -- -- -- 6.02 6.02 6.02 -- 8.56 8.56 8.56 -- 11.13 -- 13.49 17.12 (Welded Type) (Welded Type)
5 125 141.3 3.40 -- -- -- 6.55 6.55 6.55 -- 9.53 9.53 9.53 -- 12.7 -- 15.88 19.05
6 150 168.3 3.40 -- -- -- 7.11 7.11 7.11 -- 10.97 10.97 10.97 -- 14.27 -- 18.26 21.95
8 200 219.1 3.76 -- 6.35 7.04 8.18 8.18 8.18 10.31 12.70 12.70 12.70 15.09 18.26 20.62 23.01 22.23
10 250 273.1 4.19 -- 6.35 7.8 9.27 9.27 9.27 12.70 12.70 12.70 15.09 18.26 21.44 25.4 28.58 25.4
12 300 323.9 4.57 -- 6.35 8.38 9.53 9.53 10.31 14.27 12.70 12.70 17.48 21.44 25.4 28.58 33.32 25.4
14 350 355.6 4.78 6.35 7.92 9.53 -- 9.53 11.13 15.09 -- 12.70 19.05 23.83 27.79 31.75 35.71 --
16 400 406.4 4.78 6.35 7.92 9.53 -- 9.53 12.7 16.66 -- 12.70 21.44 26.19 30.96 36.53 40.49 --
18 450 457.2 4.78 6.35 7.92 11.13 -- 9.53 14.27 19.05 -- 12.70 23.83 29.36 34.96 39.67 45.24 --
20 500 508.0 5.54 6.35 9.53 12.7 -- 9.53 15.09 20.62 -- 12.70 26.19 32.54 38.1 44.45 50.01 --
22 550 558.8 5.54 6.35 9.53 12.7 -- 9.53 -- 22.23 -- 12.70 28.58 34.93 41.28 47.63 53.98 --
24 600 609.6 6.35 6.35 9.53 14.27 -- 9.53 17.48 24.61 -- 12.70 30.96 38.89 46.02 52.37 59.54 --
26 650 660.4 -- 7.92 12.7 -- -- 9.53 -- -- -- 12.70 -- -- -- -- -- -- Galvanized Steel Slip Flexible Mechanical
Galvanized Steel End Cap Galvanized Steel Blind Flange
700 -- 7.92
On Flange Grooved Coupling
28 711.2 12.7 15.88 -- 9.53 -- -- -- 12.70 -- -- -- -- -- --

47 48
Foam Fire Extinguishing System Fire Hose Rack & Reel

Foam Fire Extinguishing System


Fire hose reel
Foam Bladder Tank is to provide foam solution for fire foam system. It is mainly consist of pressure ank , bladder,
proportioner, control valves, pressure gauge and pipelines. High-pressure water is needed to swap out foam
concentrate(stored in bladder in the tank) from the tank as a certanin proportion. Foam concentrate then mix with Specification
pressurized water and form foam solution. The concentrate is discharged from the tank by incoming water applying
Material: Rubber
pressure to the bladder. This applied energy is transferred to the concentrate,supplyying pressurized concentrate to the
proportioner. (Proportioners are separate items described on a separate data sheet.) For bladder is separated from the Length: 30m
water that it can be utilized next time if not finished.Besides, there is feed inlet to refill or rehange foam concentrate.
Size: DN19 (3/4") & DN25 (1")
With valve
With nozzle
Swing automatic and manual for options

Fire hose rack

Horizontal type Vertical type


Specification

Material: Canvas

Length: 30m

Size: DN40 (1.5") &DN65 (2 (1/2"))


Coupling: aluminum x 2pcs
Nozzle: brass or plastic for options

Right angle valve: brass


With hose rack

Features

Big flow pressure range and small pressure loss.

Widely used both in mid-multiples and low multiples foam extinguishin system.
Hose Rack Hose Adapter Right Angle Valve
Two types: horizontal and vertical.

Hose Nozzle Hose Coupling


Fire Hose
Foam Monitor Foam Chamber

49 50
Hose Accessories & Fire Blanket Sprinkler Series

Embedded & Wall-mounted type Cabinet


Customizable size and design cabinet for options

Fire hose reel cabinet Fire hose reel cabinet Fire hose cabinet Extinguisher cabinet

Fire Blanket

Fire Blanket Box Package Fire Blanket Plastic Package

Fire Blanket Box Package


Glass bulb type fire sprinkler
Model Number Fire Blankets Size Net weight (pcs) Gross weight (pcs) Quantity(pcs of box)/Size

AW-FB101 1m*1m 0.45kg 0.7kg 20pcs/ 52 ×34 ×21cm

AW-FB103 1.2m*1.2m 0.64kg 0.9kg 20pcs/ 52 ×34 ×21cm

AW-FB105 1.5m*1.5m 1.10kg 1.3kg 15pcs/ 52 x34 ×21cm

AW-FB107 1.2m*1.8m 0.93kg 1.35kg 15pcs/ 52 x34×21cm

AW-FB109 1.8m*1.8m 1.39kg 1.8kg 10pcs/ 42 ×34×21cm

Fire Blanket Plastic Package


Model Number Fire Blankets Size Net weight (pcs) Gross weight (pcs) Quantity(pcs of box)/Size

AW-FB102 1m*1m 0.45kg 0.5kg 30pcs/ 42 ×34 ×21cm

AW-FB104 1.2m*1.2m 0.64kg 0.7kg 20pcs/ 42 ×34 ×21cm

AW-FB106 1.5m*1.5m 0.98kg 1.1kg 15pcs/ 42 x34 ×21cm

AW-FB108 1.2m*1.8m 0.95kg 1.05kg 15pcs/ 42 x34×21cm

AW-FB110 1.8m*1.8m 1.39kg 1.45kg 10pcs/ 42 ×34×21cm

51 52
International Certificates and Patents International Certificates and Patents

53 54
International Certificates and Patents International Certificates and Patents

55 56

You might also like