Professional Documents
Culture Documents
2022
System Manufacturer & Complete
Solution Provider.
LPCB Conventional
Fire Alarm Control System
AW-CFP2166
05-09 Addressable Fire Alarm Control System 31 Voice Evacuation Control Panel and Speakers
17-18 Wireless Conventional Fire Alarm System 35-36 Detector tester Series
19-20 Aspirating Smoke Detection System 37-39 Gas Suppression Release Control System
We focus on international standard and certificate fire safety products, until now we already got LPCB, TUV,
BSI, Intertek CE, Bomba ,ATEX certificates for our different products.
We support to design the projects based on NFPA and other international standards. All projects are designed
and verified by highly skilled engineering team. Moreover, we support our customers at site in different
countries for commissioning and other necessar y supports for the completion and submittal of the projects.
1 2
LPCB Approved Addressable Fire Alarm Control System LPCB Approved Addressable Fire Alarm Control System
Addressable Gas Detector Addressable Sounder Beacon AW-D306 Addressable Manual Call Point
AW-AGD2188 Conventional Sounder Beacon AW-D316 AW-D305
The AW-FP300 single loop 32 zone fire alarm control panel offers the following features Signal Loop 24V(18V~28V)
Operating Voltage
Power 24VDC(20VDC~28VDC)
Up to 324 addresses in one loop, 648 addresses in two loops Standby Current Loop≤0.8mA ; Power≤2mA
Action Current Loop≤5mA ; Power ≤15mA
An easy to read,4.3" color screen LCD with a resolution of 480x272 Output Capacity 1A@DC30V
Input Mode Setting NC or NO input mode can be set
Zone indication and control panel (ZCP)for 32 zones gives a quick indication of the by the jumper JP4.
location of an alarm or fault
Record capacity of 1000 historical events for each of historical fire,historical fault
and historical operation
CAN bus for interconnection of up to 20 FACPs and RS-485 for connection with
up to 30 fire indicating panels per FACP
3 4
Addressable Fire Alarm Control System Addressable Fire Alarm Control System
The AW-FP100 fire alarm control panel offers the following features
5 6
Addressable Fire Alarm Control System Addressable Fire Alarm Control System
This CAN Bus Transmitter AW-D122 is designed for extend the distance of
CAN Bus communication. It is suggested to be installed over each 400
meters.
Addressable Smoke Detector Addressable Heat Detector Addressable Smoke and Heat Detector
AW-D101 AW-D102 AW-D103
The gas detector is designed for single station use or for connecting to fire
alarm or security alarm panel. Small and compact, the design and color
makes it ideal for use in the home, small commercial properties, and
recreational vehicles. It is intended to detect leakage of natural gas
(methane gas),town gas, and bottled gas (propane gas) The gas detector
can be mounted high (for methane gas) or low (for propane (LPG) gas). It is
equipped with a sturdy mounting bracket for quick , easy and safe
installation.
Features
Detect all sorts of combustible gases, natural gas (methane), bottled gas (propane),LPG(Liquefied petroleum Gas),
Wireless Batter y Heat Detector Wireless Smoke and Heat Detector Wireless Batter y Smoke Detector LNG (Liquefied natural gas), including town gas.
AW-STD606A AW-SST606A AW-SSD606A
Easy to install, mounting bracket included.
Addressable Alarm Bell Addressable Strobe Sounder Addressable Manual Call Point
AW-D109 AW-D106 AW-D135A
Addressable Monitor Addressable Super visor y Addressable Control Addressable Relay Isolator Module
Module Module Module Module
AW-D110 AW-D111 AW-D112 AW-D113 AW-D114
7 8
Addressable Fire Alarm Control System ASENWARE Global Fire Alarm Graphic Monitoring System
Addressable Annunciator
AW-D116
Features
Three lines of 40 character each LCD
Features
24 Zones Addressable
AW-D117
Annunciator LED Main Board
Automatically send Emails & SMS to the building managers, engineers or concerned person for fire or fault events
Addressable Power Transmitter
CLOUD mode can monitor all running panels around the world
AW-D121
User-friendly,easy to operate and manage to operate and manage
Addressable Power Transmitter, an intelligent power supply,
which is designed to provide auxiliar y power when there is not
Aesthetic design while maintaining the simplicity in drag and drop feature for devices to the layout
enough power from panel to devices.
Features
Addressable
5A@24VDC output
EN54-4 standard
9 10
LPCB Conventional Fire Alarm Control System LPCB Conventional Fire Alarm Control System
Main Voltage
M a in V o lta g e Zone 24V / 12V Main Voltage
M a in V o lta g e Zone 24V / 12V Operating voltage: 9VDC
M a in V o lta g e
Alarm Sensitivity 0.1 to 0.15 dB/m Alarm Sensitivity 0.18~0.3 dB/m Alarm Sensitivity 0.18~0.26 dB/m
Features
AW-CFP2166 series conventional fire alarm panel is designed based on
EN54 part 2&4 standard.
Rate of Rise Temp Heat Detector Rate of Rise Temp Heat Detector
It is modularized design, the panel can expand from 1 zone to 32 zones easily. ROR/A2R ROR/A2R
AW-CTD382 AW-CTD321
It has 2 levels control mode by a lock .
Main Voltage
M a in V o lta g e Zone 12V/24V DC Main Voltage
M a in V o lta g e 9-28V DC
It has an optional GSM module for fire alarm by SMS. Monitoring Status ≤120uA Monitoring Status ≤120uA
11 12
LPCB Conventional Fire Alarm Control System LPCB Conventional Fire Alarm Control System
Standalone LPG GAS Detector Conventional UV Flame Detector Conventional 4 Wire CO detector Conventional Sounder Beacon Repeater Entrance LED Indicator
AW-CGD2166 AW-FD602-UV AW-D125C AW-D316 AW-CRP2166 AW-EL102
Standalone batter y CO detector
AW-D125S
13 14
Conventional Fire Alarm Control System Wireless Conventional Fire Alarm System
Operating Environment
Addressable Strobe Sounder Wireless Manual Call Point Programm address for each device
AW-D106A AW-D135A AW-PR101
15 16
Wireless Conventional and Addressable Fire Alarm System Wireless Conventional and Addressable Fire Alarm System
Conventional Fire Alarm Wireless Addressable Wireless Addressable Wireless Addressable Wireless Addressable
Control Panel Smoke Detector Heat Detector Smoke Detector Heat Detector
AW-CFP2166-2W/4W AW-D603 AW-D604 AW-D603 AW-D604
Wireless Addressable
Smoke Detector
Wired & Wireless Addressable Strobe Sounder AW-D603
Fire Alarm Control Panel with Wireless Transmitter
AW-FP214 AW-M601
Standalone Wireless Batter y
Wifi Smoke Detector
AW-D611W
Max 20
wireless devices
Wireless Addressable Wireless Addressable Wireless Addressable in one zone
Heat Detector Smoke and Heat Detector Manual Call Point
AW-D604 AW-D605 AW-D135A
17 18
Aspirating Smoke Detection System Aspirating Smoke Detection System
Combustion analysis:
Temp Phisical Change
Phisical and Chemical Change
Thermal
Stable Decomposition
Condition
Incipient Stage
of Fire Time
Fire detection
Aspirating Smoke Detection System Aspirating Smoke Detection System
with Cloud
AW-AS200 AW-AS100 Chamber
Principle
Advantages
Earlier detection with high sensitivity
Advanced Al applications
Cost effective maintenance solution
Features
Cloud Chamber principle
19 20
Weather Proof Fire Alarm Devices ATEX Approved Explosion-Proof Fire Alarm Products
Explosion-Proof Infrared
Fire Alarm Weather Proof Series
Beam Smoke Detector
AW-BK901EX
Features
Features Features
Height: 64mm
Horn Strobe
AW-CSS2166-4W
Applicable Products
Suitable for most models
of smoke detector
Applicable Products
Features
Protection level:IP67 Explosion-proof fire alarm bell Explosion-proof safety barrier Explosion-proof strobe sounder
AW-CBL2166EX AW-D137EX AW-CSS2168EX
Function:Dust-proof;Rain-proof
Main Voltage 24 VDC Main Voltage DC 24V Main Voltage DC 24V
Operating current Alarm≤25 mA Operating current Alarm≤25 mA Operating current Alarm≤250 mA
L*W*H:120*190*110mm
Ex-Atex Protection Level Exd II CT6 Gb Ex-Atex Protection Level Exd II CT6 Gb Ex-Atex Protection Level Exd II CT6 Gb
Size (L*W*H) 260* 152* 80mm Size (L*W*H) 260* 152* 80mm Size (L*W*H) 260* 152* 80mm
Conventional
Weather proof Box Manual Call Point
AW-D135C
21 22
ATEX Approved Explosion-Proof Fire Alarm Products ATEX Approved Explosion-Proof Fire Alarm Products
AW-EXD104 intelligent digital readout transmitter is a two-wire system and meet the international standard digital transmitter
which can convert the gas concentrations into standard 4-20mA current signal. It"s suitable for the industrial LED to display and
the sensor easy to use and plug and play. AW-EXD104 have many advantages: high performance, stable and reliable operation,
easy to install and maintain, and it can measure full range of gas and so on, which can meet the high demand in the industrial
site safety monitoring. It widely used in petroleum, chemical, engineering,metallurgy, petrochemical, gas transmission and
distribution, biochemical, medicine,
water treatment and other industries.
23 24
ATEX Approved Explosion-Proof Flame Detector ATEX Approved Explosion-Proof Flame Detector
Explosion-proof ultraviolet Explosion-proof Ultraviolet Explosion-proof Ultraviolet & Infrared Explosion-proof Infrared 3
& infrared 3 flame detector Flame Detector Combined Flame Detector Flame Detector
Ex-Atex Protection Level Exd II 2 G Ex d IIC T6 Gb Exd II 2 G Ex d IIC T6 Gb Ex-Atex Protection Level Exd II 2 G Ex d IIC T6 Gb Exd II 2 G Ex d IIC T6 Gb
120mm* 95mm* 85mm 120mm* 95mm* 85mm 120mm* 95mm* 85mm 120mm* 95mm* 85mm
25 26
Fire Linear Heat Cable Fire Linear Heat Cable
Easy to install, test, and splice. Alarm 68°C 88°C 105°C 138°C 180°C
Temperature
Compatible with other initiation devices
on same circuit.
Ambient
45°C 60°C 75°C 93°C 121°C
temperature (Max)
-55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type -55°C for CR/OD Type
Ambient
Temperature (Min)
-40°C for -40°C for -40°C for -40°C for -40°C for
Conventional Conventional Conventional Conventional Conventional
and EP Type and EP Type and EP Type and EP Type and EP Type
27 28
Fire Linear Heat Cable Fire Linear Heat Cable
Wrapping:aluminum foil
High temperature resistance
Outer jacket: Red (UL 105° PVC-55P)
Halogen and smoke free
Quality Assurance
2.2±0.1
Inner wire brown.blue(flame retardant PVC)
29 30
Voice Evacuation Control Panel and Speakers Addressable Fire Telephone System
AW-VP350 Voice Evacuation Control Panel and The fire fighting telephone system is suitable for
speakers is a standalone public audio system for communication and dispatching during any fire
emergency evacuation. When get alarm input or emergency in the building. In case of fire alarm
from other fire alarm system or security alarm at the application site, the site personnel can call
system, it can play the pre-recorded audio track the host through extension and contact the
to the speakers automatically. It also can control center in time. The operator in the
broadcast the microphone real time sound, or control center can also call the extension at the
other line in sound. It also support RS485 site through the host to know the situation on
communication with ASENWARE AW-FP300 the site.
series addressable fire alarm control panel.
Features Features
Maximum power output: 350Watt. With the two-bus technology, the power supply and communication are compatible on two buses, and are not divided
into the positive and the negative, convenient for debugging
Speaker driving mode: constant voltage.
It has perfect detection measures, which can detect the short circuit and open circuit of the bus, and make sound and
Evacuate message up to 1 minute. light alarm
The anti-interference performance of hardware and software allows for the adaptability tovarious complex environments.
Background audio: USB2.0
The voice is subject to differential transmission on the bus, with strong anti-interference capability.
Complies with EN54 part 16.
The application of silica gel button presents a beautiful appearance, good hand feeling and long ser vice life.
Network function (work with AW-FP300 series addressable fire alarm control panel)
The host and extension can call each other and make full-duplex call, and the host can communicate with three
Maximum 15 pcs AW-VP350 can be connected with 1 pcs AW-FP300 addressable fire alarm control panel. extension telephones at the same time.
It has the function of recording and displaying the calling and answering time, and can quer y 120 records of calling and
2.6.2 Each AW-VP350 panel can be programmed to maximum 20 channels and controlled by AW-FP300 addressable response time between the host and the extension.
fire alarm control panel
The recording is subject to circular coverage, first-in-first-out mode and automatic recording is enabled during a call.
AW-FTP2008 (8 zones), AW-FTP2016 (16 zones) fire telephone panel is a new fire
special communications equipment,when the fire accident, which provides a
convenient means of communication, the fire control and alarm systems
necessar y communications products. Wall-mounted structure is easy to install,
Ceiling Speaker Ceiling Speaker Wall Mounted Speaker 15W Water Proof Speaker 30W Water Proof Speaker suitable for small systems.
AW-SP01 AW-SP02 AW-SP03 AW-SP04 AW-SP05
31 32
Centralized Monitoring Emergency Luminaire System Centralized Monitoring Emergency Luminaire System
Features
Easy operating
Convenient using
Communicated by PLC
Easy Mounting
Features
Up to 16 lighting zones;
Up to 16 testing group;
Detecting batter y fault, LED source fault, AC fault and communication fault for single emergency lighting;
220V-240VAC 50/60Hz
AW- EL203 Nickel-cadmium 3.6V
<24 hours
220VAC 50/60Hz
1800lm
Twin Lamp AW-EL208
Emergency Light <24 h
220VAC 50/60Hz
≥130lm
LED Lamp AW-EL103
The installation can be performed per below figure in actual condition.Exit Lights and Emergency lighting can be Emergency Light <24h
connected to directly from the panel and power would be supplied from the panel itself. Panel has two sources, one is AC
mains and another one is 24 Volts batter y (or two 12V batteries).
33 34
Detector tester Series Detector tester Series
Smoke&Heat Detector
Heat detector tester 2in1 Tester
AW-D202 AW-D206
Accessor y list
Flame simulator
Smoke detector tester AW-D204 Smoke & Heat Detector
AW-D201 Disassembly tool
AW-D208
Flame simulator
AW-D204
Features
Batter y voltage:DC7.4V.2200MA/H
35 36
Gas Extinguishing System Gas Extinguishing Release Control System
Fire Bell
AW-CBL2166-6
Mode Switch
AW-GD203
Sequence Starter
Manual Release Station Abort Switch
AW-GD201 AW-GD202 AW-GD205
AW-FMEV80
FM200
37 38
Gas Extinguishing Release Control System FM-200 Gas Extinguishing System
Features
Alarm input: four alarm zones signal input, each zone can connect up to 16 detectors.
Panel outputs: circuit fault output / alarm output/ fire extinguishing signal output/24VDC output other parts working
condition.
Automatic power shift: 220VAC power and standby batter y power can be switched automatically.
GSM module (optional): GSM module allows users to receive alarm information by SMS.
Asenware Clean Agent Fire extinguishing systems utilizes FM-200 as extinguishing gas. Asenware FM-200 systems are
available as Engineered and Pre-Engineered Systems (Cabinet System).
39 40
Packaged Fire Pump System Water Based Fire Products
Features
Common Base
Automatically run and stop jockey pump, electrical motor pump and diesel pump.
Full test with pressure guage and flow meter at same time.
41 42
Water Based Fire Products Water Based Fire Products
Nominal pressure(MPa) DN H1 H2 H3 D1 D2 L1
50 70 130 68 120 95 43
Thread Type Landing Valve 2 Way Breeching Inlet 4 Way Breeching Inlet
43 44
Water Based Fire Products Water Based Fire Products
L H
Nominal pressure(MPa)
DN spiral flange spiral flange
65 225 135
80 280 175
Clean water
and sewage
1. 76 without ≤80℃
1.6MPa 2.4
impurities
flange
DN25
1.6MPa ON50
DN65
Saddle type DN80
1.2 15<Q<37.5
DN100
DN125
welded DN150
DN200
45 46
ASTM A53 seamless steel pipe ASTM A53 seamless steel pipe
Standard: ASTM A53, Type S, Grade B Tensile strength (Mpa) Yield Strengt(Mpa) Elongation(%)
Dimension: Sch40 /Sch80 as ASME B36.10M
Application: Fire main pipe, fire pump pipe,
fire standpipe, fire sprinkler branch pipe , ≥330 ≥205 ≥29.5
Black and red seamless pipe is available
≥415 ≥240 ≥29.5
Pipe Fittings
N o r minal Outside
P i p e Size Diameter Norminal Wall Thickness
Galvanized Steel Pipes Galvanized Steel Elbow 90° Galvanized Steel Elbow 90° Galvanized Steel Tee
N PS DN D SCH10s SCH10 SCH20 SCH30 SCH40 s STD SCH40 SCH60 S C H80 s XS S C H80 SCH100 S C H120 SCH104 SCH160 XXS (Welded Type) (Threaded Type) (Welded Type)
47 48
Foam Fire Extinguishing System Fire Hose Rack & Reel
Material: Canvas
Length: 30m
Features
Widely used both in mid-multiples and low multiples foam extinguishin system.
Hose Rack Hose Adapter Right Angle Valve
Two types: horizontal and vertical.
49 50
Hose Accessories & Fire Blanket Sprinkler Series
Fire hose reel cabinet Fire hose reel cabinet Fire hose cabinet Extinguisher cabinet
Fire Blanket
51 52
International Certificates and Patents International Certificates and Patents
53 54
International Certificates and Patents International Certificates and Patents
55 56