Hauberk А5 EN
Hauberk А5 EN
2. Manual on Installation 19
General recommendations on installation 20
on timber surfaces
Stages of Installation 22
3. Design Installation 29
4. Technical Solutions 35
TN-FACADE Light HAUBERK 36
TN-FACADE HAUBERK 37
3
1.
General Information
Product Description
Application Areas
Exterior wall covering, renovation and decoration of facade, its architectural
elements (gable, entrance groups etc.), household buildings, fences and
enclosures.
wooden house construction
stick-frame houses
aerated concrete block houses
fences, enclosures
GENERAL INFORMATION 6
Advantages
7
* Production is certified by the latest version of the International Standard of Quality ISO 9001:2015.
8
Technical Characteristics
Parameters Value
Protective covering type on the bottom Quartz sand with a protective film covered
area
AFTER
BEFORE
Color
SANDY BRICK
AFTER
AFTER
Color BEFORE
TERRACOTTA BRICK
and SANDY BRICK
AFTER
YEARS
MANUFACTURER’S
WARRANTY
Metal coating Aluzinc AZ 150 (150 g/m2) Zinc grade 2 Z120 ÷ Z140
(120 ÷ 140 g/m2)
19
General recommendations on installation
on timber surfaces
*For detailed information on warranty terms, please, visit the official website www.tn-hauberk.eu
10. 9.
8.
7. 5.
6.
4. 1,2.
3.
The decking for exterior wall shingles is timber surface with a thickness of not less
than 9 mm. The decking should be dry (relative moisture of the timber — not more
than 20%), solid (2–3 mm gaps between decking elements) and rigid.
Before installation of exterior wall shingles thoroughly observe the surface of the
facade and eliminate all visible defects.
2. Surface marking
Before installation of exterior wall shingles the surface of the decking should
be marked with lines, which serve as indicators and help to align the exterior
wall shingles horizontally and vertically. Besides, they help to align exterior wall
shingles TECHNONICOL HAUBERK when the surface of the facade is divided by
some element (e.g. entrance group, window etc.).
Fig. 8.4. Installation of window joint flashing Fig. 8.5. Completed window frame
on top of the frame
Alternative 2
Firstly, install the soffit. Exterior wall
shingles are installed till the eave
overhang, afterwards the metal
Soffit flashing is installed, which is fastened
Install metal flashing every 100 mm.
(fasten every 100 mm)
Exterior wall shingles
TECHNONICOL HAUBERK
Eave flashing
29
Design Installation
DESIGN INSTALLATION 30
Fig. 1. Foundation wall arrangement
DESIGN INSTALLATION 31
Principles of pattern design:
1. Exterior wall shingle consists of 4 separate «tabs».
2. Installation to be performed with a half-«tab» shift.
3. Total pattern is diagonal.
4. When installing the rows, the shingles to be interlocked, and the overlying
row, when shifted, should cover the junction of the underlying shingles.
5. To exclude displacement of the shingles and obtain the pattern of correct
brickwork, there are ticks on the upper part of each shingle, which serve as
indicators during installation and are important to cut the «tabs» when creat-
ing a pattern.
Fig. 6. Division of a shingle into «tabs» Fig. 7. Division of a «tab» into halves
DESIGN INSTALLATION 32
2. During works one can use any separate «tab» of any color from the color
palette.
3. To start with, make a layout of the future pattern on a scheme and paint it
by colors. Consider that one «tab» is 25 cm wide and 10 cm high.
10 сm
25 сm
4. Then calculate the shingles in rows. The first row starts with a half of the dark-
colored “tab”. Then it is joint with light-colored “tabs”. The second row starts with
a whole dark-colored “tab” and continues in light-colored “tabs”. The remaining
halves are used in arrangement of opposite cornerposts. The pattern is ready.
DESIGN INSTALLATION 33
34
4.
Technical solutions
35
TN-FACADE Light HAUBERK System
Timber cage system with exterior wall covering
1. Building cage
2. Stone wool
3. Vapor barrier
6.
4. Superdiffusive membrane
5. (three-layer microporous
7. membrane)
2. 8. 5. Counter battens
6. Inner soffit (plaster wallboards
1.
3. or gypsum-fiber sheets)
4. 7. Block for ventilated cavity,
30–50 mm thick
9.
8. OSB-3
9. Exterior wall shingles
TECHNONICOL HAUBERK
1. Masonry
2. Cage for heat insulation
with a span of 600 mm
3. Stone wool
1. 4. Superdiffusive membrane
2. (three-layer microporous
6. membrane)
5. Block for ventilated cavity,
5.
30–50 mm thick
6. OSB-3
3.
7. 7. Exterior wall shingles
TECHNONICOL HAUBERK
4.
HAUBERK 38
HAUBERK 39 ТАБЛИЦА ПОДБОРА
КОМПЛЕКТУЮЩИХ
WWW.TECHNONICOL.EU