You are on page 1of 6

2023

GUSTAFS PANEL SYSTEM DESIGNED FOR EYES AND EARS

WALL, ACOUSTIC PERFORATIONS

A PANEL WITH MANY UNIQUE BENEFITS


Most of our products are based on a fibre gypsum board which has very good properties regarding both
fire safety and acoustics. The panel is less sensitive to changes in temperature and humidity which in turn
maintains the panels’ linearity over time. All together, this unique combination contributes to a panel suited
for applications not only in large areas but also in a wide variety of demanding situations.

FIBRE GYPSUM CORE SOLID WOOD EDGING IT’S A SYSTEM

Our panels are based on a fibre gypsum Prior to veneering, a solid wood edging Gustafs Panel System provides fully integral
board which has excellent properties is integrated around the panel, disguising and concealed installation fixtures called
regarding dimension stability, impact the core material. When the veneer is then Gustafs Capax. On top of that the instal-
resistance, fire safety and acoustics, applied it covers the wooden edge and lation is quick, reliable and cost saving,
demands which effectively eliminate most effectively gives the panel the appearance meeting the demands of today’s modern
traditional wood-based choices. Gustafs of being entirely of wood. This process building processes. Due to the Fibre Rein-
panels are not sensitive to changes in contributes to the total strength of the forced Gypsum Core, the Gustafs Panels
temperature and humidity which in turn panel making it more robust and ensures System is extremely dimension stable and
maintains the panels’ linearity and flatness its dimensional characteristics. allows beautiful “zero spacing installations”
over time. Altogether, this unique of large formatted panels up to 3000x1200
combination results in a panel suited for mm.
large areas and a wide variety of deman-
ding situations.

LEADING ACOUSTICS,
DESIGNED FOR EYES & EARS

EUROCLASS A2-s1,d0
STABILITY ENERGY SUSTAINABILITY FIRE ACOUSTICS
SAVING
Wood based panels will Due to the panel’s high Using a fiber gypsum core The high density nonflam- Acoustically, the use of
show bulging or shrin- density and its low level of naturally results in extre- mable core and the surface innately heavy wall cladding
kage when humidity and thermal conductivity, the mely low emissions and a veneer’s strongly bound is often favourable com-
temperature change. A fiber material helps to maintain very high rate of recycled adhesion to the fiber pared to lighter materials.
gypsum board is considera- room temperatures at a content. Being located gypsum board make our Gustafs panels weight of
bly less susceptible to these constant level and reduces in Sweden gives us the panels “non-flammable”. 15 kg/m² is roughly twice as
effects. Over time this will the need for cooling or opportunity to produce with Reaction to fire A2-s1,d0, heavy as most wood-based
result in a planer and more heating. renewable power sources resistance to fire K110/K210. panel materials.
linear surface. only.

Gustafs Panel System / Wall / Acoustic Perforations / Product Sheet 2018-01-17 1/6
SURFACES - FREEDOM IN DESIGN

VENEER LACQUER & GLOSS STAINED & PIGMENTED


Wood has a natural variation in structure and Prior to delivery the panels are given a resi­lient You can also apply pigmented lacquers or stain
colour tone which ages in harmony with nature. and attractive surface finish. A clear lacquered the veneer to achieve different effects on your
The fact that wood is a natural material is an finish is by far the most common maintenan- wall or ceiling. Different veneers react different
intrinsic aspect of its charm and attraction. On ce-free and durable finish for wooden surfaces. to certain treatments so contact us to guarantee
Gustafs.com you find our veneer collection. It Utilizing a multi-stage UV-lacquering process, that the final result matches your vision.
goes without saying that we do our outmost to our surface finish achieves these demands
fulfill requests for other veneers. We offer two while aspiring to maintain technical ­aspects A pigment can be used to change the colour tone
choices of genuine veneer, NATURE and GEMINI. such as our fire retardation and environmental of the veneer on Gustafs Panels and we have for
goals. Our lacquer is a multi-layer UV-cured example developed a three stage scale of white
process which is available in a range of gloss pigment for veneers.
finishes. The lowest gloss gives the impression
of a subdued oiled surface whereas the highest
reaches almost a mirror-like surface.

SOLID PAINT ART LAMINATE


Some surfaces are very highly demanding. With Gustafs Art there are many options to Many interiors utilize the beauty, simplicity and
Among the many advantages of a Gustafs panel decorate the panel surface, route out your logo resistance to impact of laminated surfaces. You
is its plane and even surface. This enables us to or create a printed pattern over the entire surface choose what laminate* we should use. With
create a painted surface finish which otherwise is come to us with your idea. laminates you can design beautiful surfaces that
extremely difficult to achieve on site. Utilizing our are durable, impact resistant and easy to clean.
production technology we can produce painted BF-PRINT Of course we can supply these laminated panels
surfaces in a multitude of colors in accordance Gustafs can now offer new design opportunities with acoustic perforations and a fire classification
with for example NCS or RAL codes up to a gloss with Gustafs BF-Print. You can design every panel that meets the high standards for public rooms.
rate up to 50. in a completely unique way. Design panel by
panel or spread your graphics over several panels We also offer a standard collection of metal lami-
with a seamless transference. nates including, among others, alluminium, brus-
You can have your print directly on the veneer, hed steel and bronze, but you can also choose
laminate or craft paper. other laminates. Contact us for more information
regarding laminates.

Gustafs Panel System / Wall / Acoustic Perforations / Product Sheet 2018-01-17 2/6
FIRE CLASSIFICATIONS

Fire Classifications Gustafs Panel System


VENEER HPL CPL FOIL
System Core Material Modell
Lacquer Stain Paint Print - Print - Print - Paint Print
Plain A2-s1,d0 A2-s1,d0 A2-s1,d0 A2-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 A2-s1,d0 A2-s1,d0 A2-s1,d0
Gustafs
Perforated A2-s1,d0 A2-s1,d0 A2-s1,d0 A2-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 A2-s1,d0 A2-s1,d0 A2-s1,d0
Panel High Density Fibre Gypsum
System Nano B-s1,d0 NA NA B-s1,d0 NA NA B-s1,d0 B-s1,d0 NA NA NA
Stripes A2-s1,d0 A2-s1,d0 A2-s1,d0 A2-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 A2-s1,d0 A2-s1,d0 A2-s1,d0

Plain Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class
Gustafs
Perforated Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class
Panel FR-MDF (B-s1,d0)
System Nano Core Class - - Core Class - - Core Class Core Class - - -
Stripes Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class
Plain Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class
Gustafs
Fire Retardant Plywood Perforated Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class
Panel
(B-s1,d0) Nano Core Class - - Core Class - - Core Class Core Class - - -
System
Stripes Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class Core Class
High Density Fibre Gypsum Rib
WALL
B-s1,d0
INSTALLATION
B-s1,d0 B-s1,d0 B-s1,d0
SYSTEM
- - - - B-s1,d0 B-s1,d0 B-s1,d0
Gustafs
HIR Sandwich Rib B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 - - - - B-s1,d0 B-s1,d0 B-s1,d0
Linear Rib
System FR-MDF (B-s1,d0) Rib Core Class Core Class Core Class Core Class - - - - Core Class Core Class Core Class
WALL INSTALLATION
MDF Rib D-s2,d0 D-s2,d0 D-s2,d0 D-s2,d0 - - - - D-s2,d0 D-s2,d0 D-s2,d0

Gustafs High Density Fibre Gypsum Plank B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 - - - - B-s1,d0 B-s1,d0 B-s1,d0

EXAMPLE WALL ASSEMBLY


Linear Plank FR-MDF (B-s1,d0) Plank EXAMPLE ACOUSTIC SECTION
Core Class Core Class Core Class Core Class - - - - Core Class Core Class Core Class
System MDF Plank D-s2,d0 D-s2,d0 D-s2,d0 D-s2,d0 - - - - D-s2,d0 D-s2,d0 D-s2,d0
High Density Fibre Gypsum Module B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 - - - - B-s1,d0> 88 mm
B-s1,d0 B-s1,d0
> 17 mm > 29 mm
Gustafs HIR Sandwich Module B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 - - - - B-s1,d0 B-s1,d0 B-s1,d0
Linear Module Solid Wood Module B-s1,d0 B-s1,d0 B-s1,d0 B-s1,d0 > 38- mm - - - - > 45 mm- -
System FR-MDF (B-s1,d0) Module Core Class Core Class Core Class Core Class - - - - Core Class Core Class Core Class
MDF Module D-s2,d0 D-s2,d0 D-s2,d0 D-s2,d0 - - - - D-s2,d0 D-s2,d0 D-s2,d0
4 4 2 3
1 3 5 2
3 4
2 1 3 5 1 1 2

600 mm 600 mm 600 mm 600 mm

600 mm 600 mm 600 mm 600 mm

80 mm 80 mm 80 mm 80 mm

1 Metal batten 1 Metal batten 1 Battens and insulation 1 Battens and air space
2 12 mm Plywood n.b. board 2 2x12 mm Gypsum board 2 Capax profile 2 Battens and insulation
3 12 mm Gypsum board 3 12 mm Plywood strips 3 Gustafs panel 3 Capax profile
4 Capax profile 4 Capax profile 4 Gustafs panel
5 Gustafs panel 5 Gustafs panel

Gustafs Panel System / Wall / Acoustic Perforations / Product Sheet 2018-01-17 3/6
WALL INSTALLATION - SOLUTIONS FOR ALL NEEDS

FIXED PANELS DEMOUNTABLE CORNERS AND EDGES


PANELS

1 1 1 3204
3204 3204
2 2 2 3205 3205 3 3 3
3205 3203 3203 4 4 4
3203 3203 3203
3203 3218
5 5 5 (AV)(AV)(AV) 3218
3218
G G G

GF G
G G G G G G HP HP HP (AV)(AV)(AV) (AV)(AV)(AV)

6 6 6 3201
3201 3201
7 7 7 3202
3202 3202 8 8 8 3202
3202 3202 9 9 9 3209
3209 3209
10 10 10 3215
3215 3215
G G G HPXHPXHPX HP HP HP

G G G
CTPCTPCTP
5 mm
5 mm 5 mm 5 mm
5 mm 5 mm
G G G
G G G
G G G
HPXHPXHPX
HP HP HP
11 11 11 3208
3208 3208
12 12 12 3202
3202 320213 13 13 3202
3202 320214 14 14 3219
3219 3219
15 15 15 3201
3201 3201

G G G GP GP GP GP GP GP G G G

34 x 34 mm
34 x 34 mm
34 x 34 mm
(AV)(AV)(AV)

2 mm
2 mm 2 mm 10 mm
10 mm 10 mm 10 mm 10 mm
10 mm (AV)(AV)(AV)

G G G
GP GP GP G G G
HP HP HP
16 16 16 3217
3217 3217
17 17 17 3206 320618 18 18
3206 3202
3202 320219 19 19 3218
3218 3218
20 20 20 3205
3205 3205
(AV)(AV)(AV) GS GS GS
GP GP GP
(AV)(AV)(AV)

13 mm
13 mm 13 mm 15 mm
15 mm 15 mm

(AV)(AV)(AV)
(AV)(AV)(AV)
GS GS GS G G G
GP GP GP

21 21 21 3201
3201 3201
22 22 22 3202
3202 320223 23 23 3200
3200 3200 24 24 24 3221
3221
25 25 25 3221
G G G GP GP GP G G G
mm>90
>90>90 mmmm

Niveau
Niveau Niveau
RV RV RV
10 mm
10 mm 10 mm
GP GP GP

3203
3203 27 27 3207
3207 28 28 3200
3200 A-list
A-list 3251
a3251
a a 32 32 32
26 26 26 3203 27 3207 28 3200 29 29 29 A-list 30 30 30 3251

G G G G G G HP HP HP

(AV)(AV)(AV) (AV)(AV)(AV)
2 mm
2 mm 2 mm

Edges = G, GP GF, GS, HP, HPX, RV, AV.


X Solution number for order

Gustafs Panel System / Wall / Acoustic Perforations / Product Sheet 2018-01-17 4/6
GUSTAFS ACOUSTIC PERFORATIONS

Gustafs Acoustic Values


Ø or Slott cc Open WALL: 45 mm insulation + 30 mm air void (Hz/αp ) CEILING: 45 mm insulation + 200 mm air void (Hz/αp )
ACOUSTICS Typ
Spacing (D) (A/E) area αw NRC 125 250 500 1000 2000 4000 αw NRC 125 250 500 1000 2000 4000
PH5 5 mm - 20/20 5% 0,30-D 0,50 0,50 0,70 0,65 0,45 0,25 0,20 0,35-D 0,50 0,50 0,65 0,55 0,45 0,30 0,20
PH8 8 mm - 20/20 12 % 0,55-D 0,80 0,35 0,85 1,00 0,75 0,55 0,40 0,55-D 0,80 0,65 0,95 0,85 0,80 0,55 0,40
PH8-F 8 mm - 20/20 12% 0,60-C 0,85 0,35 0,85 0,95 1,00 0,50 0,35 0,60-C 0,85 0,55 0,90 0,95 1,00 0,60 0,35
Sound PH10 10 mm - 20/20 18 % 0,70-C 0,85 0,35 0,85 1,00 0,90 0,70 0,55 0,75-C 0,90 0,65 1,00 0,90 0,85 0,75 0,60
absorption PG5 5 mm - 20/20 3% 0,25-E 0,40 0,40 0,50 0,45 0,35 0,20 0,15 0,30-D 0,40 0,45 0,45 0,40 0,40 0,25 0,15
PG8 8 mm - 20/20 8% 0,45-D 0,65 0,40 0,85 0,80 0,60 0,40 0,30 0,50-D 0,65 0,55 0,75 0,70 0,65 0,40 0,35
PS2 3 mm - 20/20 2% 0,20-E 0,50 0,30 0,85 0,70 0,30 0,15 0,05 0,25-E 0,45 0,55 0,70 0,55 0,35 0,20 0,10
PD8 8 mm - 10/10 24 % 0,80-B 0,90 0,30 0,80 1,00 0,95 0,75 0,65 0,85-B 0,90 0,65 1,00 0,95 0,90 0,80 0,70

B Ø

C E

 ormally for wall panels B and C = 30 mm.


N
When group perforation B and C = 30 - 95 mm.
A and E = constant.

PD8 DOMINO PERFORATION 8 MM OPEN AREA 24% - ABSORPTION CLASS B PH10 PERFORATION 10mm OPEN AREA 18% - ABSORPTION CLASS C

A=10 mm A=20 mm
B=30 mm B=30 mm
C=30 mm C=30 mm
E=10 mm E=20 mm
Diameter=8 mm Diameter=10 mm

PH8PERFORATION
PH8 PERFORATION8 8MM
MM, OPEN AREAOPEN
12%AREA 12% - ABSORPTION CLASS D PH8 GROUP
PG8 PERFORATION 8 MM,8%
PERFORATION OPEN AREA OPEN
12% AREA 8% - ABSORPTION CLASS D

A=20 mm A=20 mm
B=30 mm B=30 mm
C=30 mm C=30 mm
E=20 mm E=20 mm
Diameter=8 mm Diameter=8 mm

Group measurement 200 mm x 200 mm.

PH8PERFORATION
PH5 PERFORATION 8 MM, OPEN AREA OPEN
12% AREA 5% - ABSORPTION CLASS D PH8 GROUP
PG5 PERFORATION 8 MM,5OPEN
PERFORATION MM AREA 12%AREA 3% - ABSORPTION CLASS E/D
OPEN

A=20 mm A=20 mm
B=30 mm B=30 mm
C=30 mm C=30 mm
E =20 mm E=20 mm
Diameter=5 mm Diameter=5 mm

Group measurement 200 mm x 200 mm.

PH8DOUBLE
PS2 PERFORATION 8 MM, OPEN
SIDED PERFORATION 3/10AREA
MM 12%
OPEN AREA 2% - ABSORPTION CLASS E

A=20 mm
B=30 mm
C=30 mm
E=20 mm
Diameter visable perforation = 3 mm
Diameter 2=10 mm

Gustafs Panel System / Wall / Acoustic Perforations / Product Sheet 2018-01-17 5/6
SHORT FACTS

Type Gustafs Panel System


Core Reinforced fibre gypsum board, high density, 1150 kg/m³ (15,7 kg/m²)
Edges Over veneered solid wooden edges on 4 sides
Edge design Grooved for use the Capax installation system
Acoustic felt Black / White

Thickness 13,2 mm
Dimensions Standard: 600x600 / 1200x600 / 1500x600 / 1800x600 / 2400x600 mm
Customized wall: lengths 300-3000 x widths 300-1200 mm

Joints Closed 0 mm (approved for all dimensions and both vertical & horizontal)
Wall non-demountable: Closed 0 mm / Open 5 mm, 10 mm, 13 mm
Wall demountable: Open 5 mm, 10 mm, 13 mm

Installation system Gustafs Capax, aluminium profiles gripping the full length of the sides of
the panels, levelling and aligning the panels.

Reaction to Fire A2-s1,d0 (EN 13501-1)


(Valid for the whole panel, including the installation system, the surface,
the surface treatment and all kinds of post treatments like cutting, milling)

Resistance to Fire K1-10/K2-10 (EN 13501-2)

TVOC Approved emissions (EN ISO 16000-9)


Formaldehyde Approved emissions (EN 717-1)
Urea formaldehyde Not added
Recycled Material 17% Post Consumer
Certified Wood FSC available, Certificate Code: SAI-COC-010919
EPD Available
Production Site City: Gustafs / country: Sweden
Life time Expected > 50 years

Gustafs Scandinavia AB Tel: +46 (0)243 79 20 20


Stationsvägen 1 Email: info@gustafs.com DESIGNED FOR EYES AND EARS

SE-783 60 www.gustafs.com
Gustafs, Sweden

Gustafs Panel System / Wall / Acoustic Perforations / Product Sheet 2018-01-17 6/6

You might also like