1 CTP learning records

2 The newspaper office uses the laser head of the MCE machine 2.0
3 1, identify safety hazards safety definition
4 2, describe sysptoms describe the problem phenomenon
5 3, reproduce sysptoms problem reproduction
6 4 brainstorm cause analysis reason
7 5 narrow down causes narrow the range
8 6 repair or replace defective equipment Repair or replace the damaged part
9 7 test the solution test result
10 8 prevent future occurrence prevent recurrence
11 9 document the solution record file
12 LEC head clip TEC tail clip
13 HEIP command
14 Abort terminate command abort clear resume The three commands are often used together to
15 enter the system field/export with Access /dev
16 Ale Display system pressure
17 Bay Set bay bay 1 load 30 (plate quantity) 500 700 (plate size) 300 (plate thickness)
18 Carriage moveto 500 Move laser head
19 Chiller Cool
20 Debris Set vacuum cleaner debris blower on/off
21 Door Front door lock/unlock two states
22 Dongle Speed configuration
23 Drum Set drum move/ spin (rotation) /idle (release)/stop Do not change the rest of the
parameters
24 Drum move 150 to move the drum to the position with an angle of 150.
25 Drum spin 150 to rotate the drum at a speed of 150.
26 For example, after replacing the lec,
27 set mh to
28 check the loadpos position, such as 165.456
29 Drum move 165.456
30 Lec on
31 completed
32 Edge test to detect the edge of the plate
33 Eject to eject the plate when unloading can not
34 Engine checks the status of roller, lec, and tec when it works
35 Engine init (roller, lec, tec reset)
36 Engine time Checks the execution time of the action
37 Engine resume/stop/eject When executing, it should bring engine
38 Event to display the error message in the circuit board
39 Fans only Can detect fan status
40 Feature View configuration
41 Flush continuously pushes an action load unload etc.
42 Flyoff only has flyoff clear a command
43 Focus to view the sr value (1.7 laser head in TH mode) command: focus cal reflect
44 Fmode value generally choose 0, 1, 4 News agency choose
45 1 Two commands fw dir /fwd dir)
46 Gc display gc information ppm concentration unit
47 Head laser head head reset/init/status. 1.7 The parameters changed by the laser head
will alarm when
48 Case high is higher than the set temperature, and cannot work normally.
49 Case low will alarm when the temperature is lower than the set temperature, and can work.
50 Humidity will alarm when the humidity is not suitable, and it will not work.
51 Hlt will display the information Hotlink
52 . There are roots at the laser head The hotlink line is used to transmit data. Display
hotlink information
53 Image Exposure information image status
54 Init Reset
55 Laser Laser laser on/off
56 Ldd Display laser information command ldd info
57 Lec head clip command: lec on/off/init Use engine time to view head clip cycle an action
time
58 List pattern (equivalent to address )/version/media/error
59 List pattern is used for 5, 12, (22, 33 for FM network), 50
60 Load calibrate (Enter this command to automatically detect the distance between the
sensor and the head clamp when the head clamp is faulty and automatically write to
DISTSENSOR TOLEC ), automatically correct the plate width
61 Load bay 1
62 Loaded Check whether there is a plate on the drum
63 Unload is used when unloading is not executed The flush unload command is executed
repeatedly to
64 check the warning information of the machine. In the news mode, use
65 Mce to check the information of the mce board.
66 Media removed
67 Mode displays the resolution used by the machine. Command: mode 1/2 Change the
resolution of the machine. 10000.
68 Picker
69 Plot edge Detect the distance from the laser head to the edge of the plate
70 Prm When downloading information and reporting error 34039, use the command: prm
hazardous media enable
71 Prouct to display the current information
72 Ramp Buffer plate guide plate Command: ramp in/out
73 Redirect Whether to enter the laser head mode (TH) redirect enable /disable
74 Release Release
75 Reset Reset command: reset reset all
76 Shutter Detect laser head intensity sensor (shutter) command: shutter on/off
77 Roller Press roller roller on/off
78 System Display information
79 Safety
80 Scan
81 Scan groups Scan all sensors scan al Scan autoloader scan rlr Scan roller
82 Scan tec_sensorawaysidedown( sensor name ) bon/boff Shield or enable a sensor
83 Scan bclear All shields unlock
84 Scan bstatus View currently shielded sensors
85 Scheduler View load/unload information
86 Status statuslights View light status
87 Stg erase flash/ram Clear information in flash/ram
88 Stroke stroke cal Calibrate laser stroke shutter Check shutter quality
89 Tec tail clamp on/off lock/unlock get clamp/put clamp ( automatically complete tec
on/off lock/ unlock action )
90 Temp temperature information
91 Th2 In NEWS state th2 "foc cal reflect can execute a command without necessarily
entering the laser head.
92 Adding TH2 before the command can execute a command in the laser head once.
93
94 Set the laser head of the plate media7
95 newspaper office Time 2.0
96 1 set media 7 name “tao” in news state
97 2 set invert (0 negative plate 1 positive plate)
98 3 set escanlines (extrascanlines scanning parameters, metal version) 1
99 4 set vacuum cleaner debris option (0 is off, 1 is default, 3 For blowing and sucking)
usually choose 3
100 5 redirect enable to enter the laser head TH2 mode
101 6 set media 6 name "tao" (2.0 laser head minus 1 and the rest unchanged)
102 If you want to clear the file name use the command set media 6 name " "
103 7 nvs save media save information
104 8 redirect disable return to NEWS mode
105 9 load a version of
106 Media 7 select the plate if you don’t write 7 , the default is the first plate
107 10 carriage moveto 500 (basically in the middle of the plate)
108 11 drum move 100 Rotate the roller to confirm
109 12 head install on check sum value=1100-1300 is normal error =-10-+10 normal is usually 0
110 If you are in TH2 mode, you can enter the command: foc cal reflect check
111 Saturation check laser first 0 parameters
112 Good range No problem out range Need to readjust the laser head
113 Open the panel to adjust the physical position of the laser head. At this time, the
error value
114 is basically suitable only when the two lights are on. When the forward light is on, it
must be adjusted forward, and the backward light is on. It must be adjusted backwards,
generally backwards first, and then adjusted forward a little bit
115 . After adjusting the 0-bit parameters of the laser head, the purpose of testing the sr
value is to make the sum value within the allowable range.
116 13 head install off
117 14 redirect enable Enter TH2 mode
118 15 foc cal reflect
119 16 set media 6 sr 0.02 ( set the number of times, check the sum until the allowable
range )
120 17 redirect disable
121 18 head install on
122 19 check the sum value If it is not within the allowable range, repeat steps 13-18,
enter TH2 mode and be sure to head install off
123 The corresponding DRUM SPEED of the plate is provided by the supplier or checked online.
Wpower
124 /wpowers is used for FM network in MPE equipment. Sr :
125 reflectivity of the
126 plate Sd: focal length of the plate . on
127
128
129
130
131
132
133 Picker wrist out
134 Picker airjet off
135 Picker out
136 Picker down
137 Picker vac off
138 Verbose =vbs View more information
139 Script ----device-----mce trandsetter s set power and other data test plates
140 can not be output when the test plate can be used to plot 50 test density Measure
whether it reaches 50, if it is not suitable, re-adjust the laser power
141 Service Shell, enter the IP address when remote monitoring: 172.20.123.11, etc.
142 set ehi information in the laser head
143 set statuslights status lights set
144 set hdp 1.0 head to use
145 set hdm 1.7 And the parameter md in the 1.0 head and the 2.0 head
146 mhauto set the machine to work when the plate is uploaded.
147 Keep table down After initialization, the table will keep the action, which can be set
to up/down
148 auto load vel Speed
149 set focus base thickness when the plate is loaded The focal length corresponds to the
thickness of the plate
150 carriage mspeed The speed when the motor comes back during initialization
151 set debris pressmaxnozzle Set the suction force of the vacuum cleaner
152 set exit The speed at which the plate is pushed before the plate enters the punching
machine. It is
153 necessary to change the GC after replacing the laser head and DRUM
154 set gc sshift 1 500 (can be a negative value) Move horizontally, the plate has one side
that is not exposed
155
156 Orthoadjust exposure is oblique, how to command
157
158 Prd serier number serial number how to set Temagin 7.000 Lemagin 6.000 to check the
state of
159 the blue edge First command sys /laser /head status to adjust the FOCUS, first reduce
the POWER value System to check the air pressure , set the drum speed Sd value in TH
mode, the distance of the laser knife plate for each plate is referred to as the focal
length, and the printed material is X-RITE 938 or 528 density Meter measurement, fill in
the sd value in the media, and the focal length corresponding to Focus is for all plates
Gapwith set the interval
160