Safety Precautions 02
Product Contents 04
Product PIN Diagram 06
LED indicators 06
Product Dimension 07
Installation of Panel with Casing 08
Wire Legend 09
Power Wiring Diagram 10
WEIGAND Connection 11
Exit button Connection 11
Lock connection 12
Door Sensor Connection 12
Aux. Input Connection 14
Aux. Output Connection 14
Ethernet Connection 15
RS485 Connection 16
DIP switch settings 17
Electrical Specifications 18
Troubleshooting 19
Specifications 20

1
1Safety Precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before installation.

01 02 03

Do not place a magnet near the Do not place the device next to
Do not install the device in a heating equipment
product. Magnetic objects such as
place subject to direct sun light,
magnet, CRT, TV, monitor or speaker
humidity, dust or soot.
may damage the device.

04 05 06

Be careful not to let liquid like Clean the device often to remove Do not let children touch the
water, drinks or chemicals leak dust on it device without supervision.
inside the device.

2
Safety Precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before installation.

07 08 09

Do not drop the device. Do not disassemble, repair or Do not use the device for any
alter the device. other purpose than specified.

10 11 12

Do not damage the device In cleaning, do not splash water Contact your nearest dealer in
on the device but wipe it out with case of a problem.
smooth cloth or towel.

3
Product Contents
Basic Contents

Wall mounting screws – 2 pcs. Wall Plugs– 2 pcs. Surge Suppressing Diode– 4 pcs.

screw driver – 2 pcs. Software CD C3 installation guide

C3-200
4
Product Contents
Optional accessories

Weigand Card Reader Prox Card RS485 convertor K1-1 Exit Button

Door Sensor Card enroller Alarm C3 Metal Case

5
Product PIN Diagram
SD Card Slot
LED indicators
LINK LED
Aux Input 1
Ethernet Port
Aux Input 4 LED solid green indicates
LINK
ACT LED TCP/IP communication is
(Green)
Reserved normal
DIP Switch
#1 Door Exit Flashing LED indicates data
Button ACT
communication is in
PC RS485 Port
(Yellow)
progress
#1 Door Card
485 LED
Reader1
PC RS485 Flashing LED is sending or
Aux Output 1 (Yellow & data in communication
#1 Door Card Green) progress
Aux Output 2
Reader2
#1 Lock Sensor
#2 Door Exit POWER Flashing LED indicates the
#1 Door Lock Button (Red) panel is powered on.
#2 Lock Sensor #2 Door Card
#1 Door Lock Reader 1 Flashing LED indicates that
RUN
panel is in normal working
(Green)
state
Lock Power #2 Door Card
C3 Power Reader 2
CARD Flashing LED indicates that
(Yellow) the card is read by the panel.
Status LED

6
Product Dimension

C3-200

106mm
(4.17in.)

Dimension(L*W):203.2× 106 (mm)


160mm 6.30 ×4.17(inches)
(6.30in.)
C3-Casing

330mm 330mm
(13.0in.) (13.0in.)
90.5mm
(3.56in.)
Dimensions(L*W*H): 400 *90.5*330(mm)
15.7× 13.0× 3.56(inches)
400mm
(15.7in.)

7
Installation of Panel & Case
Metal Case
Power Supply
Box Lock Hole

C3 Panel

Heat dissipation
Hole

Cable Conduit
Backup Battery

Thread Hole

Wires need to be passed through Mounting the case on the wall


this conduit

8
Wire Legend
Detector Infrared sensors #1Exit Switch #1Card Reader #2 K1-1 Exit Switch #2 Card Reader

DC
12V DC
Power

Floodlight Normal Open Lock 12V

LAN Cable RS485 Convertor Alarm Normal Close Lock Power Supply

9
Power wiring diagram
Without
Backup Battery AC 110-220V
C3-200

AC

Switching power supply

With
Backup Battery
AC 110-220V
C3-200
+
Backup Battery
-

AC

Switching power supply

10
Weigand Connection
Beeper

Green LED

Weigand D1

Weigand D0

GND

DC+(6-14V)

Weigand Card Reader

Exit Button Connection

DV12V(+)

DV12V(-)

BUT
NO

GND COM

NC

ZK ABK Exit Button


Notice:

separate power supply K1-1 Exit Switch

11
Lock Connection
Built-in Power Supply For Normally Open Lock

Sensor
Sensor

GND
12V DC
FR107

12V DC

GND

Built-in Power Supply For Normally Close Lock

Sensor
Sensor

GND
12V DC

FR107

12V DC

GND

12
Lock Connection
Switching Wet Contact to Dry Contact
Important Notes: Steps:

Default setting
C3-200 is set to supply lock power by default from 5 1
external power supply , If you want to use built-in C3-200 4 Lock Relays Select one Relay
power supply , you must do the following:
1. Select the wanted lock relay and find its Changed setting

jumpers
2. Take off the jumpers and change to 5 1
3. Connect the lock as shown in the diagram below Plug Jumpers Jumpers Take off jumpers

Connecting a lock with external power supply

GND

12V DC

FR107

SEN SEN GND 12V DC

13
Aux. I/O connection
Aux. Input Connection

12V DC
GND
COM
NO
NC

Aux. output Connection

12V DC
GND
COM
NO
NC

14
Ethernet Connection

Important Notes:

1. Both 10Base-T and 100Base-T


TCP/IP are supported
2. This cable distance must be less
than 100 meters or 330 ft.
CR10 Card Issuer 3. For cables length of more than
100m. use HUB to amplify the
The CR10 is connected to the server using USB C3-200 C3-200
connection. signal

Direct connection
To connect C3-200 with a PC directly, connect both devices with a straight network cable. As the C3-200 supports auto MDI/MDIX , it
is not necessary to use a crossover type cable.

CR10 Card Issuer

15
RS485 Connection

#63 C3-200

RS485-
RS485+
#1 C3-200 GND

Important Notes Do's and Dont's for RS 485 connection


1. RS485 communication wires should be shielded or twisted pair calble.
RS485 communication wires should be connected in a bus cascade instead
of in a star form, to achieve a better shielding effect by reducing signal
reflection during communications.
2. A single 485 bus can be connected with 63 access control panels at the
most, but preferably less than 32 panels should be connected.
3. To eliminate signal attenuation in communication cables and suppress
interference, if the bus is longer than 200 meters, set the number 8 DIP
switch to the ON position. This is equivalent to a parallel connection of one
120ohm resistance between the 485+ and 485- lines.

Distance

More than 200 meters

#1 C3-200 #* C3-200

16
DIP Switch Setting
Introduction RS485 Address

1. Number 1-6 are reserved to set the device number for RS485
communication. The code is binary, and the numbering starts from left to
right. When the switch is set to ON position, it indicates 1 (on); when the
switch is set downwards, it indicates 0 (off). For example, to set a device
number 39=1+2+4+32, which corresponds to the binary code 111001, put
number 1, 2, 3, and 6 to ON position, as illustrated below.

2. For more details, please check the table at the end of this document

Restore factory setting Terminal Resistance

1. If you forget the C3 IP address or the device does not work 1. Number 8 is for setting the RS485 termination resistance. Putting the
normally, you can use the number 7 terminal to restore C3-200 to switch to ON position is equivalent to parallel connection of a 120ohm
factory default settings. The parameters which gets reset are termination resistance between 485+ and 485-
device IP address, communication password ,gateway ,subnet mask. 2. For more information please read RS485 connection - important notes
2. The switch is OFF by default. When it is moved upwards and
downwards for three times within 10 seconds and finally returned
to OFF position, the factory settings will be restored after the
access control panel is restarted.
1 times
2 times 3 times OFF
120ohm

17
Electrical Specifications

Min. Typ. Max. Notes


Working power supply
Voltage(V) 9.6 12 14.4 Use regulated DC power adaptor only
Current(A) 2
Electronic lock relay output
Switching voltage(V) 36V Use regulated DC power adaptor only
Switching Current(A) 2
Auxiliary relay output
Switching voltage(V) 36V Use regulated DC power adaptor only
Switching Current(A) 1.25
Switch Aux. input
VIH (V) TBD
VIL (V) TBD
Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors
WIEGAND Input
Voltage(V) 10.8 12 13.5
Current(mA) 500
ZK Electronic lock
Voltage(V) 10.8 12 13.2
Current(mA) 500

18
Troubleshooting

Diagram:

1. How to switch four door one way to two door to way.


 Connect four readers from reader 1 to reader 4.
 Connect two door locks , one connect LOCK1 ,another connect LOCK3.
 Switch on software then reader 1-Indoor, reader 2-Outdoor.

2. How many WEIGAND formats are supported ?


 The panel is set to read 26 bit by default.
 However there are 9 other bit formats which can be selected from the software. In addition you
can also define your custom bit format.

3. How many verification mode can be support.


 Card only
 Password only
 Card plus password

4. Can we integrate IP Camera and NVR


 Currently ZKACCESS software supports ZKAccess’ IP Cameras and NVR
 You can associate a camera to the door and setup a linkage for the same.

5. Can C3 panel support FR1200 fingerprint reader ?


 No , Only Inbio series can support FR1200 fingerprint reader
19
Specifications
Communication RS485, TCP/IP
Baud Rate for RS485 9600-115200
Power Supply 12V DC, 3A
Card Holders Capacity 30,000
Log Events Capacity 100,000
LED Indicator Indication for communication, power, status and prox card
Environment 32-113 °F (0-45 °C)
Operating Humidity 20% to 80%
Number of doors controlled Four Door (four door one way two door two way)
Number of readers supported 4
Types of readers supported 26-bits WIEGAND, others upon request
Number of Inputs 6 (2 Exit Device, 2 Door Status, 2 AUX)
Number of Outputs 4 (2- Form C relay for lock and 2- Form C relay for Aux output)
Weight 7.8lbs (3.55kg)
Enclosure Stainless Steel
Mounting Wall Mount
Dimensions (Bundle Only) 15.7in. × 3.56in.× 13.0in 400mm(L) X 90.5mm(W) X 330mm(H)
Dimensions ( Board Only) 6.30in. X 4.17in. 160mm(L)X 106mm(W)
CPU 32 bit 400MHz
RAM 32MB
Flash 128MB
Certified

20
Attached
PC 485 Setting table

Switch Setting Switch Setting


Place Address Place Address
1 2 3 4 5 6 1 2 3 4 5 6

Address No. 1 2 4 8 16 32 Address No. 1 2 4 8 16 32


01 ON OFF OFF OFF OFF OFF 33 ON OFF OFF OFF OFF ON
02 OFF ON OFF OFF OFF OFF 34 OFF ON OFF OFF OFF ON
03 ON ON OFF OFF OFF OFF 35 ON ON OFF OFF OFF ON
04 OFF OFF ON OFF OFF OFF 36 OFF OFF ON OFF OFF ON
05 ON OFF ON OFF OFF OFF 37 ON OFF ON OFF OFF ON
06 OFF ON ON OFF OFF OFF
38 OFF ON ON OFF OFF ON
07 ON ON ON OFF OFF OFF
39 ON ON ON OFF OFF ON
08 OFF OFF OFF ON OFF OFF
40 OFF OFF OFF ON OFF ON
09 ON OFF OFF ON OFF OFF
41 ON OFF OFF ON OFF ON
10 OFF ON OFF ON OFF OFF
42 OFF ON OFF ON OFF ON
11 ON ON OFF ON OFF OFF
43 ON ON OFF ON OFF ON
12 OFF OFF ON ON OFF OFF
44 OFF OFF ON ON OFF ON
13 ON OFF ON ON OFF OFF
45 ON OFF ON ON OFF ON
14 OFF ON ON ON OFF OFF
46 OFF ON ON ON OFF ON
15 ON ON ON ON OFF OFF
47 ON ON ON ON OFF ON
16 OFF OFF OFF OFF ON OFF
48 OFF OFF OFF OFF ON ON
17 ON OFF OFF OFF ON OFF
49 ON OFF OFF OFF ON ON
18 OFF ON OFF OFF ON OFF
50 OFF ON OFF OFF ON ON
19 ON ON OFF OFF ON OFF
51 ON ON OFF OFF ON ON
20 OFF OFF ON OFF ON OFF
52 OFF OFF ON OFF ON ON
21 ON OFF ON OFF ON OFF
53 ON OFF ON OFF ON ON
22 OFF ON ON OFF ON OFF
23 ON ON ON OFF ON OFF 54 OFF ON ON OFF ON ON

24 OFF OFF OFF ON ON OFF 55 ON ON ON OFF ON ON

25 ON OFF OFF ON ON OFF 56 OFF OFF OFF ON ON ON

26 OFF ON OFF ON ON OFF 57 ON OFF OFF ON ON ON

27 ON ON OFF ON ON OFF 58 OFF ON OFF ON ON ON


28 OFF OFF ON ON ON OFF 59 ON ON OFF ON ON ON
29 ON OFF ON ON ON OFF 60 OFF OFF ON ON ON ON
30 OFF ON ON ON ON OFF 61 ON OFF ON ON ON ON
31 ON ON ON ON ON OFF 62 OFF ON ON ON ON ON
32 OFF OFF OFF OFF OFF ON 63 ON ON ON ON ON ON

21
Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry
for the product, please contact ZKTeco Inc .
ZK China :
ZK Building, Wuhe Road, Gangtou,
Bantian, Buji Town, Longgang District,
Copyright 2013 ZKTeco Inc. All right reserved. Shenzhen China.
ZKTeco May, at any time and without notice , Make changes or Tel.: +86 755-89602345
improvements to the product and services offered and/or cease sales@zkteco.com
producing or commercializing them. zkteco.com