Safety Precautions 02
Product Contents 04
Product PIN Diagram 06
LED indicators 06
Product Dimension 07
Installation of Panel with Casing 08
Wire Legend 09
Power Wiring Diagram 10
WEIGAND Connection 11
Exit button Connection 11
Lock connection 12
Door Sensor Connection 12
Aux. Input Connection 14
Aux. Output Connection 14
Ethernet Connection 15
RS485 Connection 16
DIP switch settings 17
Electrical Specifications 18
Troubleshooting 19
Specifications 20
1
1Safety Precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before installation.
01 02 03
Do not place a magnet near the Do not place the device next to
Do not install the device in a heating equipment
product. Magnetic objects such as
place subject to direct sun light,
magnet, CRT, TV, monitor or speaker
humidity, dust or soot.
may damage the device.
04 05 06
Be careful not to let liquid like Clean the device often to remove Do not let children touch the
water, drinks or chemicals leak dust on it device without supervision.
inside the device.
2
Safety Precautions
The list below is to keep user’s safety and prevent any loss. Please read carefully before installation.
07 08 09
Do not drop the device. Do not disassemble, repair or Do not use the device for any
alter the device. other purpose than specified.
10 11 12
Do not damage the device In cleaning, do not splash water Contact your nearest dealer in
on the device but wipe it out with case of a problem.
smooth cloth or towel.
3
Product Contents
Basic Contents
Wall mounting screws – 2 pcs. Wall Plugs– 2 pcs. Surge Suppressing Diode– 4 pcs.
C3-200
4
Product Contents
Optional accessories
Weigand Card Reader Prox Card RS485 convertor K1-1 Exit Button
5
Product PIN Diagram
SD Card Slot
LED indicators
LINK LED
Aux Input 1
Ethernet Port
Aux Input 4 LED solid green indicates
LINK
ACT LED TCP/IP communication is
(Green)
Reserved normal
DIP Switch
#1 Door Exit Flashing LED indicates data
Button ACT
communication is in
PC RS485 Port
(Yellow)
progress
#1 Door Card
485 LED
Reader1
PC RS485 Flashing LED is sending or
Aux Output 1 (Yellow & data in communication
#1 Door Card Green) progress
Aux Output 2
Reader2
#1 Lock Sensor
#2 Door Exit POWER Flashing LED indicates the
#1 Door Lock Button (Red) panel is powered on.
#2 Lock Sensor #2 Door Card
#1 Door Lock Reader 1 Flashing LED indicates that
RUN
panel is in normal working
(Green)
state
Lock Power #2 Door Card
C3 Power Reader 2
CARD Flashing LED indicates that
(Yellow) the card is read by the panel.
Status LED
6
Product Dimension
C3-200
106mm
(4.17in.)
330mm 330mm
(13.0in.) (13.0in.)
90.5mm
(3.56in.)
Dimensions(L*W*H): 400 *90.5*330(mm)
15.7× 13.0× 3.56(inches)
400mm
(15.7in.)
7
Installation of Panel & Case
Metal Case
Power Supply
Box Lock Hole
C3 Panel
Heat dissipation
Hole
Cable Conduit
Backup Battery
Thread Hole
8
Wire Legend
Detector Infrared sensors #1Exit Switch #1Card Reader #2 K1-1 Exit Switch #2 Card Reader
DC
12V DC
Power
LAN Cable RS485 Convertor Alarm Normal Close Lock Power Supply
9
Power wiring diagram
Without
Backup Battery AC 110-220V
C3-200
AC
With
Backup Battery
AC 110-220V
C3-200
+
Backup Battery
-
AC
10
Weigand Connection
Beeper
Green LED
Weigand D1
Weigand D0
GND
DC+(6-14V)
DV12V(+)
DV12V(-)
BUT
NO
GND COM
NC
11
Lock Connection
Built-in Power Supply For Normally Open Lock
Sensor
Sensor
GND
12V DC
FR107
12V DC
GND
Sensor
Sensor
GND
12V DC
FR107
12V DC
GND
12
Lock Connection
Switching Wet Contact to Dry Contact
Important Notes: Steps:
Default setting
C3-200 is set to supply lock power by default from 5 1
external power supply , If you want to use built-in C3-200 4 Lock Relays Select one Relay
power supply , you must do the following:
1. Select the wanted lock relay and find its Changed setting
jumpers
2. Take off the jumpers and change to 5 1
3. Connect the lock as shown in the diagram below Plug Jumpers Jumpers Take off jumpers
GND
12V DC
FR107
13
Aux. I/O connection
Aux. Input Connection
12V DC
GND
COM
NO
NC
12V DC
GND
COM
NO
NC
14
Ethernet Connection
Important Notes:
Direct connection
To connect C3-200 with a PC directly, connect both devices with a straight network cable. As the C3-200 supports auto MDI/MDIX , it
is not necessary to use a crossover type cable.
15
RS485 Connection
#63 C3-200
RS485-
RS485+
#1 C3-200 GND
Distance
#1 C3-200 #* C3-200
16
DIP Switch Setting
Introduction RS485 Address
1. Number 1-6 are reserved to set the device number for RS485
communication. The code is binary, and the numbering starts from left to
right. When the switch is set to ON position, it indicates 1 (on); when the
switch is set downwards, it indicates 0 (off). For example, to set a device
number 39=1+2+4+32, which corresponds to the binary code 111001, put
number 1, 2, 3, and 6 to ON position, as illustrated below.
2. For more details, please check the table at the end of this document
1. If you forget the C3 IP address or the device does not work 1. Number 8 is for setting the RS485 termination resistance. Putting the
normally, you can use the number 7 terminal to restore C3-200 to switch to ON position is equivalent to parallel connection of a 120ohm
factory default settings. The parameters which gets reset are termination resistance between 485+ and 485-
device IP address, communication password ,gateway ,subnet mask. 2. For more information please read RS485 connection - important notes
2. The switch is OFF by default. When it is moved upwards and
downwards for three times within 10 seconds and finally returned
to OFF position, the factory settings will be restored after the
access control panel is restarted.
1 times
2 times 3 times OFF
120ohm
17
Electrical Specifications
18
Troubleshooting
Diagram:
20
Attached
PC 485 Setting table
21
Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry
for the product, please contact ZKTeco Inc .
ZK China :
ZK Building, Wuhe Road, Gangtou,
Bantian, Buji Town, Longgang District,
Copyright 2013 ZKTeco Inc. All right reserved. Shenzhen China.