Professional Documents
Culture Documents
W h e n I N N O VAT I O N m e e t s D e n t a l I m p l a n t . .
INNO-SUBMERGED IMPLANT
Submerged Implant System Flow
Hex
FixtureLevel
Procedure I
Hybrid S Ø4.0 Hybrid S Ø5.0/6.0 Hybrid L Ø4.0 Hybrid L Ø5.0/6.0 Hybrid Ti-Block Scanbody
Impression
Prosthetic
034p 034p 035p 035p 035p 036p 036p 036p 037p 037p
039p 040p 040p 040p 040p 041p 041p 041p 041p 042p
039p 039p
Procedure II
Prosthetic
Multi Multi Multi Multi Impression Multi Multi Multi Meta G Multi Plastic Multi Titanium Polishing
Multi S Multi A Protection Cap Scanbody Hybrid Ti-Base Coping Transfer Post Lab Analog ULCA Cylinder UCLA Cylinder Cylinder Protector
Hex 2.5
044p 044p 044p 044p 045p 045p 045p
044p
Procedure III
Prosthetic
Length Lock Lock Look Look Lock Pick-up Lock Lock Meta G Lock Titanium
7 / 8 / 10 Protection Cap Scanbody Hybrid Ti-Base Impression Coping Lab Analog UCLA Cylinder Cylinder
12 / 14
16 / 18 mm
047p 047p 047p 047p 047p
Procedure IV
Prosthetic
Diameter
Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0
Abutment Level
Absolute Protection Cap Impression Cap Lab Analog Plastic Coping
Impression
048p
Procedure V
Prosthetic
Direct
Impression
Straight
Sonator
Impression Sonator
Sonator S Sonator A Coping Analog
054p 054p
Procedure VII
Prosthetic
Ball
Ball Analog
Submerged Implant No-Mount
Diameter
> Packing Unit : 1 Fixture + 1 Cover Screw
Ø3.5
Length
Submerged Fixture 7 -
SUB.
HEXAGON Surface Treatment : SLA-SH® 8 ST3508SM
Hex
8 10 12 14
SYSTEM > Interchangeable with Hexagonal Morse Tapered Fixture 10 ST3510SM L
> Internal Hex Connection (Taper 11°/ Hex 2.5)
12 ST3512SM
14 ST3514SM D
7 ST4007SM
8 ST4008SM
7 8 10 12 14 16 18
10 ST4010SM
L
12 ST4012SM
14 ST4014SM
16 ST4016SM D
18 ST4018SM
Diameter
Ø4.5
L Length
7 ST4507SM
8 ST4508SM
7 8 10 12 14 16 18
10 ST4510SM L
12 ST4512SM
14 ST4514SM
D
16 ST4516SM
D 18 ST4518SM
Diameter
INNO Fixture Code Length
Ø5.0
S T 40 10 S M Ex.)
7 ST5007SM
Type body Diameter Length Surface Treatment Mount SLA No-Mount ST4010SM
Submerged Taper Ø4.0 10mm SLA No-Mount 8 ST5008SM 7 8 10 12 14
10 ST5010SM L
12 ST5012SM
S T 40 10 S Ex.) 14 ST5014SM
D
Type body Diameter Length Surface Treatment Mount SLA Pre-Mount ST4010S
Submerged Taper Ø4.0 10mm SLA Pre-Mount
Diameter
Ø6.0
Length
7 ST6007SM
7 8 10 12
8 ST6008SM
L
10 ST6010SM
12 ST6012SM
D
14 -
Pre-Mount > Packing Unit : 1 Fixture + 1 Cover Screw + 1 Mount Fixture Mount
12 ST3512S
14 ST3514S D
Diameter
Ø4.0
Length
*&YUSB1SPEVDU
Cover Screw
7 ST4007S 7 8 10 12 14 16 18 Length 3 4.2 5.2
L 2SCS000 2SCS001 2SCS002
8 ST4008S
10 ST4010S > Packing Unit : 1 Cover Screw
12 ST4012S L > To Seal the Conical Interface of Fixture
> Longer Cover Screw for Deeply Inserted Fixture
14 ST4014S > Tightened with 1.2 Hex Driver
16 ST4016S D
>Tightening Torque Force : 5~10 N.cm
18 ST4018S
Diameter
Ø4.5
Length
7 8 10 12 14 16 18
7 ST4507S
Healing Abutment
8 ST4508S D
10 ST4510S Diameter Ø4.5 Ø5.5 Ø6.5
L
L Length
C 1 2 2 2
12 ST4512S Cuff 1 1
14 ST4514S 1 2HS4511 2HS5511 2HS6511
16 ST4516S D 2 2HS4522 2HS5522 2HS6522
18 ST4518S 3 2HS4532 2HS5532 2HS6532
4 2HS4542 2HS5542 2HS6542
5 2HS4552 2HS5552 2HS6552
Diameter
Ø5.0
Length 7 2HS4572 2HS5572 2HS6572
7 8 10 12 14
7 ST5007S Diameter Ø7.5 Ø8.5 Ø9.5
8 ST5008S Length
Cuff 2 2 2
10 ST5010S L 3 2HS7532 2HS8532 2HS9532
12 ST5012S
> Packing Unit : 1 Abutment
14 ST5014S > For Remodeling Gingival Contour during Soft Tissue Healing
D
> Select according to Gingival Height and Abutment Type
> Tightened with 1.2 Hex Driver
> Tightening Torque Force : 5~10 N.cm
Diameter
Ø6.0
Length
7 8 10 12
7 ST6007S
8 ST6008S
L
10 ST6010S
12 ST6012S
14 - D
Hybrid S Ti-Base
Prosthetic Procedure I D
L
1.2 Hex. Type Hex
Components Selection Guide for Ti-Base & Block, Cemented and UCLA Abutment 2.15
Diameter Ø4.0 Ø5.0 Ø6.0
C Length
Cuff 3.75 3.75 3.75
2.45 2.15
0.8 2SLH404 2SLH504 2SLH604
Hybrid L Ti-Base
(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
D
(Hex) (Hex) (Hex) (N-Hex) Cemented Angulated Milling
Abutment Abutment Abutment Type Hex
Hybrid S Ti-Base Hybrid L Ti-Base Hybrid Ti-Block L 1.2 Hex.
Diameter Ø4.0 Ø5.0 Ø6.0
C 2.15 Length
Cuff 5.5 5.5 5.5
1 2SLH415 2SLH515 2SLH615
Ø4.0 Ø5.0 Ø6.0 2 2SLH425 2SLH525 2SLH625
(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
3 2SLH435 2SLH535 2SLH635
Easy Temporary Temporary Meta G UCLA Plastic UCLA
Abutment Abutment Abutment Abutment > Packing Unit : 1 Ti-Base + 1 Abutment Screw > Library available for EXOCAD®, 3Shape®,
> For Screw-Cement or Screw Retained Abutment Dental Wings® and Others
> Titanium Base for Strength of CAD/CAM > Connected with Abutment Screw (2SSHR200)
Customized Zirconium Abutment or Crown > Tightened with 1.2 Hex Driver and Torque Wrench
> Gold Color for More Translucent Restoration > Tightening Torque Force : 30 N.cm
> Cutting Surface (Ø4.0) and Humped Design (Ø5.0, Ø6.0) > Use Scanbody for 3D Work
for Anti-Rotation of Prosthesis > Fixture Level Impression
Model Scanning Method
(Hex)
Scanbody Replica
Hybrid Ti-Block
D D
1.2 Hex.
> Packing Unit : 1 Ti-Block + 2 Abutment Screws > Connected with Abutment Screw (2SSHR100)
Hex N-Hex > For Screw-Cement or Screw Retained Abutment > Tightened with 1.2 Hex Driver and Torque Wrench
> Block Abutment for CAD/CAM Customized Abutment > Tightening Torque Force : 30 N.cm
> Library available for EXOCAD®, 3Shape®, > Use Scanbody for 3D Work
(Hex) (N-Hex) (Hex) (N-Hex) Dental Wings® and Others > Fixture Level Impression
Pick-up Impression Coping Transfer Post
Scanbody
D
Intra-oral Scanning Method Open or Closed Tray Impression Diameter Ø4.3
1.2 Hex.
Length
Cuff 8
L 2.45
2 2SSB4329
Healing
Fixture Cover Screw Abutment
Cemented Abutment Milling Abutment
Type Hex D
D 1.2 Type Hex N-Hex
1.2 Diameter Ø4.5 Ø5.5 Ø6.5
L Diameter Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
Length
L
Cuff 4 5.5 7 4 5.5 7 4 5.5 7 Length
C Cuff 7 7 7 7 7 7
C 1 2SCH4514 2SCH4515 2SCH4517 2SCH5514 2SCH5515 2SCH5517 2SCH6514 2SCH6515 2SCH6517
2 2SMH4527 2SMH5527 2SMH6527 2SMN4527 2SMN5527 2SMN6527
2 2SCH4524 2SCH4525 2SCH4527 2SCH5524 2SCH5525 2SCH5527 2SCH6524 2SCH6525 2SCH6527
* "CVUNFOU4DSFX Hex N-Hex 4 2SMH4547 2SMH5547 2SMH6547 2SMN4547 2SMN5547 2SMN6547
3 2SCH4534 2SCH4535 2SCH4537 2SCH5534 2SCH5535 2SCH5537 2SCH6534 2SCH6535 2SCH6537
2SSHR200
4
> Packing Unit : 1 Abutment + 1 Abutment Screw
Hex N-Hex 2SCH4544 2SCH4545 2SCH4547 2SCH5544 2SCH5545 2SCH5547 2SCH6544 2SCH6545 2SCH6547
> For Screw-Cement or Cement Retained Prosthesis
5 2SCH4554 2SCH4555 2SCH4557 2SCH5554 2SCH5555 2SCH5557 2SCH6554 2SCH6555 2SCH6557 > Block Abutment for Customized Contouring
> Gold Color for More Translucent Restoration (Hex) and Classification with N-Hex
> Connected with Abutment Screw (2SSHR100)
Type N-Hex
> Tightened with 1.2 Hex Driver and Torque Wrench
Diameter Ø4.5 Ø5.5 Ø6.5 > Tightening Torque Force : 30 N.cm
Length > Fixture Level Impression
Cuff 4 5.5 7 4 5.5 7 4 5.5 7
1 2SCN4514 2SCN4515 2SCN4517 2SCN5514 2SCN5515 2SCN5517 2SCN6514 2SCN6515 2SCN6517
2 2SCN4524 2SCN4525 2SCN4527 2SCN5524 2SCN5525 2SCN5527 2SCN6524 2SCN6525 2SCN6527
3 2SCN4534 2SCN4535 2SCN4537 2SCN5534 2SCN5535 2SCN5537 2SCN6534 2SCN6535 2SCN6537
4 2SCN4544 2SCN4545 2SCN4547 2SCN5544 2SCN5545 2SCN5547 2SCN6544 2SCN6545 2SCN6547
5 2SCN4554 2SCN4555 2SCN4557 2SCN5554 2SCN5555 2SCN5557 2SCN6554 2SCN6555 2SCN6557 Easy Temporary Abutment
> Packing Unit : 1 Abutment + 1 Abutment Screw D
Transfer Post
Plastic UCLA Abutment D
> Packing Unit : 1 Abutment + 1 Abutment Screw 15 (Long) 2STH45L 2STH55L 2STH65L 2STN45L 2STN55L 2STN65L
(Short) (Long) (Short) (Long)
Hex N-Hex > Same Purpose of Use as Meta G UCLA Abutment but Low Accuracy of Connection Hex N-Hex > Packing Unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid Type)
> PMMA Material
2 Pieces 1 Piece > For Closed Tray Impression
> Connected with Abutment Screw (2SSHR100)
> Connected with Guide Pin
> Tightened with 1.2 Hex Driver and Torque Wrench
> Tightened with 1.2 Hex Driver and Torque Wrench
> Tightening Torque Force : Finger Light Force during Wax Pattern Fabrication, 30 N.cm after casting
> Fixture Level Impression
Abutment Screw
Diameter
1.2 Hex. 1.2 Hex. Length 2.45 2.15
8.5 2SSHR100 2SSHR200
2.45 2.15
> Packing Unit : 1 Abutment Screw
> 2SSHR100: Hybrid Block / Scanbody / Angulated / Milling / Temporary / Meta G UCLA / Plastic UCLA Abutment Guide Pin
L > 2SSHR200: Hybrid S & L Ti-Base / Cemented / Easy Temporary Abutment
> Tightened with 1.2 Hex Driver and Torque Wrench Type
Length Pick-up Impression Coping
L
22.2(Short) 2SISR001SS
26.2(Long) 2SISR001SL
Replica Length 12
Type
L 2SRHR001 Length Transfer Post
> Packing Unit : 1 Replica L 16.3(Short) 2STH001SS
> Mimicking of Conical Interface of Fixture
20.3(Long) 2STH001SL
> Analog of Fixture for Cast Model
Prosthetic Procedure II Multi S Abutment Cuff
Diameter
1
Ø4.5
2SMS451
Ø5.5
2SMS551
D
Component Selection Guide for Multi S&A Abutment 2 2SMS452 2SMS552
C
3 2SMS453 2SMS553
1 Piece 4 2SMS454 2SMS554
Polishing Protector 5 2SMS455 2SMS555
(Hex) (N-Hex)
Multi A Abutment Type Hex
Multi Hybrid Ti-Base (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) Diameter(Angle)
D Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
Multi Meta G Multi Plastic Multi Titanium A
1.2 Hex. Cuff
UCLA Cylinder UCLA Cylinder Cylinder 2 2SMAH45152
C 3 2SMAH45153 2SMAH45303 2SMAH55153 2SMAH55303
L
4 2SMAH45154 2SMAH45304 2SMAH55154 2SMAH55304
5 2SMAH55155 2SMAH55305
Model Scanning Method
(Hex) (N-Hex)
2 Pieces Type N-Hex
Hex N-Hex
Diameter(Angle)
Multi Scanbody Cuff
Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
Lab Analog
2 2SMAN45152
3 2SMAN45153 2SMAN45303 2SMAN55153 2SMAN55303
4 2SMAN45154 2SMAN45304 2SMAN55154 2SMAN55304
5 2SMAN55155 2SMAN55305
Holder
KMHS01
(N-Hex)
Lock Scanbody Lock Lab Analog
S Machine Driver
KMMSD21L
S Ratchet Driver
KRMSD15L
Healing
Fixture Cover Screw Abutment
Lock Abutment Diameter
Lock Lab Analog Diameter Ø4.5
D Cuff Ø4.5
2SLA45
0.5 2SLA400
1 2SLA410 > Packing Unit : 1 Analog
C
> Replacement of Abutment Shape in Cast Model
2 2SLA420 > Connected with Guide Pin
3 2SLA430 > Tightened with 1.2 Hex Driver and Torque Wrench
4 2SLA440
> Packing Unit : 1 Abutment > Integrated with Screw and Abutment
> For Screw-Retained Prosthesis > Tightened with Lock Ratchet Driver and Torque Wrench
> Titanium Base for Cylinder > Tightening Torque Force : 30 N.cm
> Gold Color for More Translucent Restoration > Abutment Level Impression
Lock Meta G UCLA Cylinder Diameter Ø4.5
2SLCH45
Lock Protection Cap Diameter Ø4.5 > Packing Unit : 1 Cylinder + 1 Cylinder Screw > Cast with Non-Previous Metal or Gold Alloy
D > For Screw, Cement or Screw-Cement Retained Prosthesis > Connected with Cylinder Screw
2SLP45 > Modification to Various Types of Abutment > Tightened with 1.2 Hex Driver and Torque Wrench
> Packing Unit : 1 Cap > CCM Alloy Core for Precise Connection > Tightening Torque Force : 30 N.cm
> Protection from Cheek and Tongue for Gingival Healing Period
> Gingival Retraction for Prosthodontic Margin of Abutment
Diameter Ø6.5
> Packing Unit : 1 Abutment + 1 Production Cap
1.2 Hex Driver > For Cement Retained Prosthesis
(Crown) (Bridge) Length
Cuff 4 5.5 7 > Cutting Surface for Anti-rotation of Prosthesis
Plastic Coping
1 2SAC6514 2SAC6515 2SAC6517 > Integrated with Screw and Abutment
> Tightened with 1.2 Hex Driver and Torque Wrench
2 2SAC6524 2SAC6525 2SAC6527 > Tightening Torque Force : 30 N.cm
3 2SAC6534 2SAC6535 2SAC6537 > Abutment Level Impression
4 2SAC6544 2SAC6545 2SAC6547
5 2SAC6554 2SAC6555 2SAC6557
Lab Analog
Black
Block Out Processing
Outer Cap Spacer male
Straight Abutment
Healing
Fixture Cover Screw Abutment
Straight Abutment
D Diameter Ø3.5 Ø4.5 Analog
Length
Cuff 8 8
7 5.5 L 0.5 2SSCM308 2SSCR408
4
1 2SSCM318 2SSCR418
C
2 2SSCM328 2SSCR428
3 2SSCM338 2SSCR438
4 2SSCM348 2SSCR448 Impression Coping
Shoulder Driver
Diameter Ø4.0
KRR19L
> Packing Unit : 1 Driver
> To Install Straight Abutment
Healing
Fixture Cover Screw Abutment
Sonator S Abutment
Black
Block Out Processing
Outer Cap Spacer male
Outer Cap
2.25mm
Code SONOC01
Outer Cap Black Processing male
Ø5.4 > Packing Unit : 2 Outer Caps and 2 Black Processing Male
H-Type Inner Caps > Black Processing Male: Inserted and Removed with I&R Driver
Ø5.4
NH-Type Inner Caps
Red : Orange : Green :
Retention Force Retention Force Retention Force
About 10N About 15N About 22N
> Packing Unit : Sonator A Abutment + Abutment Screw + Carrier + 3 NH-Type Inner Caps + Outer Cap
+ Block-out Spacer + Black Processing Male Sonator Impression Coping
> For Implant Supported Over-denture Prosthesis Length 4.4
> Stable with Low Vertical Height SONIP04
1.2 Hex Driver
Ø4.0 > 6 kinds of Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for Sonator A Abutment) L
15˚ > Path Compensation up to 35 ° based on 2 Implants > Packing Unit : 4 Impression Copings
> Connected with Abutment Screw (2SSHR330) > Connected over Sonator Abutment after Placing Block-out Spacer
> Carrier : Used for delivery of the abutment > For Close Tray Impression
L
> Tightened with 1.2 Hex Driver and Torque wrench
> Tightening Torque Force : 30 N.cm
> Abutment Level Impression
Sonator Lab Analog
Length 10.2
SONLA04
Hex Driver
Type Machine
Socket
L Hex
Length Hex 1.2
22(Short) KMD12S
28(Long) KMD12L
Type Ratchet
Hex
L Length Hex 1.2
15(Short) KHD1215
21(Long) KHD1221 Ball Analog
27(X-Long) KHD1227
Healing
Fixture Cover Screw Abutment
I & R Driver
SONIR002
> Used to Insert and Remove Inner Caps and Block Processing Male
Ball Abutment Diameter
Cuff Ø4.0
1 2SBAT414R
Outer Cap O-ring
2 2SBAT424R
4.45mm
3 2SBAT434R
4 2SBAT444R
5 2SBAT454R
Socket
D
> Ball Driver
4mm
C KRB19L
*&YUSB1SPEVDU
Ball Abutment
> Packing Unit : 1 Ball Abutment + 1 Socket (1 Outer Cap + 1 O-ring )
> For Implant Supported Over-denture Prosthesis
> Tightened with Ball Driver and Torque Wrench
> Tightening Torque Force : 30 N.cm
> Direct Impression
Socket
BATC004
Outer Cap O-ring > Packing Unit : 4 Sockets
Outer Cap
BATC003C
> Packing Unit : 2 Outer Caps
O-ring
BATC003I
> Packing Unit : 4 O-rings
Ball Analog
D
L
Diameter
Length Ø4.0
4 SBAL400