You are on page 1of 1

ATTERBERG LIMITS TEST REPORT

Reference :ASTM D4318-18

LIQUID LIMITS
70%
65%
60%

MOISTURE
55%
50%
45%
40%
35%
30%
1 10 100
BLOWS

Determination of Liquid Limits Tested Date : 24 Nov 2022

Trial #1 #2 #3
Weight of Wet Sample+Can (g) w1 84.3 75.6 69.2
Weight of Dry Sample+Can (g) w2 62.4 59.2 56.4
Weight of Can (g) w3 30.1 30.4 30.5

Dry Sample (g) w4=(w2-w3) 32.3 28.8 25.9


Water Content (g) w5=(w1-w2) 21.9 16.4 12.8
% of Moistuer w5x100÷w4 68.00 57.20 49.30

No. of Blows 12 18 30
Determination of Plastic Limits
Trial #1 #2 #3
Weight of Wet Sample+Can (g) w1 52.3
Weight of Dry Sample+Can (g) w2 46.2
Weight of Can (g) w3 30.2

Dry Sample (g) w4=(w2-w3) 16.0


Water Content (g) w5=(w1-w2) 6.1
% of Moistuer (w5x100÷w4) 38.30
Average 38.30
Summary of Test after Correction Factor
Liquid Limit : 53
Plastic Limit : 38
Plastic Index : 15

Client: Mohammad Hamoud Shkher Al Ezi Date: 28-Nov-22


Project: Plot No. 755 Al Muruj-2 Ref: HIS-1001
Location: Al Muruj-2 Tabuk, K.S.A Sample BH-3-S6

Tested By: Technical Manager

You might also like