Basic Checks
The biggest mistake technicians can make is to and hour meter reading. This will keep us from getting
assume they know the problem before starting to work confused trying to count to the proper fault code storage
on a truck. Unfortunately while making our life easier location and the information may later prove helpful. I
self-diagnostics also make us more susceptible to this would suggest that these codes only be zeroed out
type of mistake. Never start to fix a truck based solely after the truck is repaired and running properly.
on the number on the dash or handset display. Always
follow the basic troubleshooting steps. Now we can utilize the Status Codes in the following
pages to find the component or area to check for our
fault. A bad card can cause virtually any problem
Talk to the operator imaginable, yet it is the one part we cannot test.
Therefore any Status Code could be the result of a
• Confirm their description of the problem with card failure. If all the pertinent areas to check are in
an operational check. proper operating condition then check all the card
inputs and if they are good then we have no choice
but to replace the card. Some discretion here is
• Visually inspect cables, connectors, contactor
advisable as approximately 70% of the control cards
tips, etc.
replaced have nothing wrong with them. Ironically
enough this is about the same ratio as is found in the
• Perform basic battery cables to frame resistance automotive industry for computers on cars.
tests. You should have at least 20,000 ohms.
Notes
• Check the battery condition.
On-Board Diagnostics
7-2
EV100ZX DIAGNOSTIC STATUS CODES
On-Board Diagnostics
7-3
EV100ZX DIAGNOSTIC STATUS CODES
TABLE OF CONTENTS
STATUS DESCRIPTION PAGE
CODE
Blank No input voltage to control card or display ................................................................ 7-5
-00 Battery is extremely discharged ................................................................................. 7-6
-01 No input signal from seat switch ................................................................................ 7-6
-02 Forward switch closed on initial start ......................................................................... 7-7
-03 Reverse switch closed on initial start ......................................................................... 7-7
-04 Start switch - low voltage after start........................................................................... 7-8
-05 Start or Brake switch did not close ............................................................................ 7-8
-06 Accelerator depressed, no direction selected ............................................................ 7-9
-07 Accelerator input voltage too high.............................................................................. 7-9
-08 Accelerator input voltage too low or power to control card after key in ON position 7-10
-09 Both Forward and Reverse switches closed at same time...................................... 7-10
-11 Start switch is closed when the key switch is closed and voltage is applied to the control card .7-11
-15 Battery volts too low ................................................................................................. 7-11
-16 Battery volts too high ............................................................................................... 7-12
-17 Wrong control card installed..................................................................................... 7-12
-21 Accelerator input is less than 0.25 volts .................................................................. 7-13
-23 Coil current low, Forward or Reverse contactor ..................................................... 7-13
-24 Voltage at T2 too low ............................................................................................... 7-14
-25 1A contactor does not open or opens too slowly ..................................................... 7-14
-26 Shorted coil driver for 1A, RB, or PS contactor ....................................................... 7-15
-41 Open thermal protector or motor control temperature too high .............................. 7-15
NOTE: Motor speed is decreased when code -41 is indicated
-42 Motor sensor input missing (green wire).................................................................. 7-16
-43 Motor sensor input missing (yellow wire) ................................................................. 7-16
-44 1 REC did not turn OFF correctly ............................................................................ 7-17
-45 1 REC did not turn ON correctly .............................................................................. 7-17
-46 T2 voltage too high .................................................................................................. 7-18
-47 2 REC does not turn ON correctly ........................................................................... 7-18
-48 T2 voltage too low .................................................................................................... 7-19
-49 5 REC does not turn ON correctly ........................................................................... 7-19
-50 C1 voltage too low ................................................................................................... 7-20
-51 C1 voltage too high with high motor current ............................................................ 7-20
-52 C1 voltage too high with low motor current ............................................................. 7-21
-53 1 REC does not go OFF during plugging ................................................................ 7-21
-54 Short-circuit, Forward, Reverse or 1A contactor coil driver ..................................... 7-22
-57 Polarity check, current sensor input voltage ............................................................ 7-22
-70 Current sensor input missing (wire #22) .................................................................. 7-23
-71 Current sensor input missing (wire #21) .................................................................. 7-23
-72 Regenerative braking contactor does not energize ................................................. 7-24
-73 Regenerative braking contactor does not de-energize or de-energizes slowly ....... 7-24
-74 Regenerative braking contactor energizes too slowly ............................................. 7-25
-75 1 REC does not go OFF during regenerative braking ............................................. 7-25
-76 C1 voltage too high during regenerative braking ..................................................... 7-26
-90 Voltage at terminal 1 of the TMM at zero volts ........................................................ 7-26
-92 Voltage at terminal 4 of the TMM at zero volts ........................................................ 7-27
-94 Voltage at terminal 8 and 10 of the TMM at zero volts ............................................ 7-27
(*) Not used on all models of lift trucks. Status Codes in this group will flash on the display.
7-4
EV100ZX DIAGNOSTIC STATUS CODES
TABLE OF CONTENTS
STATUS DESCRIPTION PAGE
CODE
-95 Voltage at terminal 11 and 12 of the TMM at zero volts ......................................... 7-28
-99 Maintenance Alert Code........................................................................................... 7-28
-117 Wrong control card installed (*)................................................................................ 7-29
-123 Pump PMT contactor coil current is too low (*) ....................................................... 7-29
-124 Voltage at T2 too high (*) ......................................................................................... 7-30
-125 1A contactor does not de-energize or opens too slowly (*) ..................................... 7-30
-141 Open thermal protector or motor control temperature too high (*) .......................... 7-31
-142 Motor sensor input missing (green wire) (*)............................................................. 7-31
-143 Motor sensor input missing (yellow wire) (*) ............................................................ 7-32
-144 1 REC did not go OFF correctly (*).......................................................................... 7-32
-145 1 REC did not go ON correctly (*) ........................................................................... 7-33
-146 T2 voltage too low (*) ............................................................................................... 7-33
-147 2 REC did not go ON correctly (*) ........................................................................... 7-34
-148 Voltage at T2 too low (*)........................................................................................... 7-34
-149 5 REC does not go ON correctly (*) ........................................................................ 7-35
-150 C1 volts low (*) ......................................................................................................... 7-35
-151 C1 volts high with high motor current (*) ................................................................. 7-36
-152 C1 volts high with low motor current (*) ................................................................... 7-36
-154 Short-circuit in electronic driver for the hydraulic pump contactor or 1A contactor (*) ....... 7-37
-157 Polarity check, current sensor input voltage (*) ....................................................... 7-37
(*) Not used on all models of lift trucks. Status Codes in this group will flash on the display.
POSSIBLE CAUSE
Positive or negative control voltage is not present. CONTROL
• Insure that the key switch is closed and voltage FUSE KEY
Circuits valid is present between PZ7 & PZ3 control SWITCH
negative. Also check for voltage between TB4 ➤
➤
for and PZ3 control negative.
Traction
Open circuit between logic card Plug Y & the POWER
Controller Dash Display or Handset. TB4
FUSE
& • Check for an open circuit or loose connection ➤
going from the “Y” plug and the Dash Display
Pump or Handset. P
Controller
➤
7-5
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Battery extremely over discharged.
POSSIBLE CAUSE
Mis-adjusted or defective seat or deadman
KEY SEAT
switch.
SWITCH SWITCH
➤
7-6
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Forward directional switch is closed on initial SEAT BRAKE
start up (i.e. closure of battery, key switch or SWITCH SWITCH
Circuits valid seat/deadman switch). ➤
• Return directional switch lever to neutral and
for then return lever to forward position.
Traction ACCEL
Forward directional switch is welded closed or START
Controller mis-adjusted to be held closed. SWITCH
• Replace or adjust directional switch to insure TB4 TB3
that it opens when the directional switch is
returned to neutral.
POSSIBLE CAUSE
SEAT BRAKE
Reverse directional switch is closed on initial
SWITCH SWITCH
start up (i.e. closure of battery, key switch or
Circuits valid seat/deadman switch). ➤
• Return directional switch lever to neutral and
for then return lever to reverse position.
Traction ACCEL
Reverse directional switch is welded closed or START
Controller mis-adjusted to be held closed. SWITCH
TB4 TB3
• Replace or adjust directional switch to insure
that it opens when the directional switch is
returned to neutral.
TB2
Short circuit between TB3 and TB6. REV
• Disconnect the wire from TB6 and check for
a short circuit between TB3 and the wire.
TB6
Defective logic card.
• Disconnect wire at TB6 and measure voltage.
It should be less than 60% of battery volts.
7-7
EV100ZX DIAGNOSTIC STATUS CODES
➤
for switch is closed. If either of these codes START
Traction appear, return directional switch to neutral and SWITCH
then select the desired direction.
Controller
Excessive leakage from TB2 to battery negative.
• Check voltage at TB2 with key and seat ➤
switches closed and directional switch in
neutral. Voltage should be greater than 60% of
➤
battery voltage.
• If less than 60% battery voltage. Remove wire TB2
and measure ohmic value from wire to SCR
negative. Value should be less than 22k ohms.
TB1
7-8
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Accelerator pedal is depressed before closing ACCEL
CONTROL
forward or reverse directional switch.
➤
• Status code will disappear when directional
Circuits valid switch is closed or when accelerator pedal is FWD
REV
DIR SWITCH
released.
for FWD
REV
FOOT DIR SWITCH
TB5
TB6
TB1
shown in Trouble Shooting Diagram.
7-9
EV100ZX DIAGNOSTIC STATUS CODES
Defective Card.
• Disconnect wire from TB1. Measure voltage
TB1
from TB1 to negative. Voltage should be
greater than 4.5 volts, if not, replace card.
POSSIBLE CAUSE
➤
Defective card.
• Disconnect wires and measure voltage at TB5
and TB6. Voltage should be less than 60% of
battery volts.
7-10
EV100ZX DIAGNOSTIC STATUS CODES
➤
voltage at TB2 is less than 60% battery volts
for before closing the start switch pedal. START
Traction SWITCH
Short circuit between battery positive and TB2 in
Controller start switch input circuit.
• Disconnect wire from TB2. Check for short
circuit from wire to battery positive. Resistance
should be greater than 4.7K ohms.
Defective card.
• Disconnect wire from TB3. Measure voltage TB2
from TB3 to negative. Voltage should be zero,
if not, replace card.
• Check for JP1 Jumper in card on wrong pins.
POSSIBLE CAUSE
Discharged battery. BATTERY
CONNECTION MINIMUM
• Check battery for proper open circuit voltage NOMINAL
LIMIT VOLTS
➤
7-11
EV100ZX DIAGNOSTIC STATUS CODES
➤
7 REC
battery being used. See Handset instructions
Circuits valid for details. Adjust to proper setting. BATTERY
CONNECTION
➤
PA4
for
➤
Battery over-charged or incorrect battery used.
Traction • Check battery for proper open circuit voltage
per table in trouble-shooting diagram. If voltage
Controller excessive-check battery for proper output BATTERY MAXIMUM
voltage. NOMINAL
LIMIT VOLTS
BATTERY
AT 2.40 VDC
• Defective accelerator. VOLTS
PER CELL
➤
BATTERY
CONNECTION 24 28.8
36 43.2
48 57.6
72 86.4
84 100.5
POSSIBLE CAUSE
Invalid card type selection.
• Review function 17 in the “Handset” section.
Adjust and set card type value as instructed
Circuits valid by the Service Manual.
for
Traction
Verify that the correct logic card catalog
Controller number is installed in the controller.
7-12
EV100ZX DIAGNOSTIC STATUS CODES
Defective Card.
• Disconnect wire from TB1. Measure voltage
TB1
from TB1 to negative. Voltage should be
greater than 4.5 volts, if not, replace card.
➤
➤
➤
➤
7-13
EV100ZX DIAGNOSTIC STATUS CODES
➤
NO nate between code 23 and code 24. Complete T2
checks for 24, if the problem is not found, perform ➤
code 23 check.
POSSIBLE CAUSE R
F
Defective F or R contactor.
Circuits valid • F or R power tips fail to close because: S1 S2
for 1) Welded normally closed power tips. FIELD
2) Binding contactor tip assembly.
Traction 3) Defective F or R contactor coil. F R
Controller (See status code 23)
Defective RB contactor.
A1
A1
• Check RB contactor power tips for closure and
➤
proper pick up. ARMATURE
• Check for open circuit or loose connections between A2
positive side of RB contactor coil and PB2.
Open Motor Circuit. RB
• Check for open circuit or loose connection in
motor circuit from the A1 connection to the A2 A2
connection on the SCR control panel.
Defective 1A, RB, PS or FW contactor.
➤
• Perform checks as outlined in status 23.
• Loose Terminal on 3 REC.
POSSIBLE CAUSE
➤
T2
➤
➤
➤
7-14
EV100ZX DIAGNOSTIC STATUS CODES
➤
➤
POSSIBLE CAUSE
Defective coil driver internal to logic card.
• Replace logic card.
Circuits valid
for
+
Traction RB +
Controller
PS +
PB6
FW
PB2
PB3
POSSIBLE CAUSE
Open thermal protector circuit.
• Check for loose connection or broken wire
Circuits valid between:
Black
-Black wire - Thermal protector and PZ1 PZ1
for -Gray wire - Thermal protector and PZ5
Traction THERMAL
Defective thermal protector. PROTECTOR
Controller • Disconnect wires from PZ1 and PZ5. At room
PZ5
temperature (25° C or 75° F) measure Gray
resistance between Black and Gray wire.
Replace TP if ohmic value is greater than 300
ohms.
7-15
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
➤
Open sensor wire circuit to PZ4.
• Check for loose connection or broken wire
(green wire) from current sensor to PZ4 on
Circuits valid the logic card. A2
for
Traction Green
SCR PZ4
Controller CURRENT
➤
SENSOR
➤
➤
NEG
POSSIBLE CAUSE
➤
➤
➤
NEG
7-16
EV100ZX DIAGNOSTIC STATUS CODES
➤
➤
➤
Circuits valid • Check for shorted 5 REC.
2 REC CHOKE
• Check for shorted 5 REC snubber (25 REC). T5
for • Power cables switched. 1X
Traction
Controller Defective 2 REC circuit.
• Check for shorted 2 REC.
• Check for shorted 2 REC snubber (22 REC).
22 REC
➤
➤
Open choke (1X). 5 REC
• Check for open circuit between T5 and T3.
Ohm meter should read zero ohms. T4 T3
Defective 1 REC. ➤
• Turn off time for 1 REC out of specification.
No field test is possible. Replace 1 REC after 25 REC
above checks, show no problem found.
POSSIBLE CAUSE
Circuits valid Defective 2 REC circuit.
1 REC Wht/Blu
• Check for shorted 2 REC. PZ8
for PZ9
• Check for shorted 2 REC snubber (22 REC). Blu
Traction
➤
7-17
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
➤
➤
Defective 1 REC. P
• Check for shorted 1 REC.
T2
➤
TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
STATUS CODE 2 REC does not turn properly. This status code will be displayed when the 2 REC
-47 fails to turn on.
7-18
EV100ZX DIAGNOSTIC STATUS CODES
➤
T2
POSSIBLE CAUSE
Defective forward or reverse contactor.
• Check for welded forward or reverse contactor F R
power tips. S1 S2
Circuits valid FIELD
• Check for sluggish operation of forward or
for reverse contactor.
F R
Traction ➤
Defective 3 REC circuit. A1
Controller • Check for shorted 3 REC. 23FL
➤
ARMATURE
3 REC
A2
• Check for shorted 3 REC snubber (23 REC).
A2
SCR
➤
CURRENT ➤
SENSOR
➤
NEG
POSSIBLE CAUSE
➤
Wire 2 REC
Controller (white/violet wire).
5 REC REACTOR
➤
T4 T3 T5 T4
Shorted 2 REC circuit.
➤
T3
• Check 2 REC and 2 REC snubber (22 REC)
REACTOR
for short circuit.
25 REC
7-19
EV100ZX DIAGNOSTIC STATUS CODES
➤
POSSIBLE CAUSE
Defective 2 REC circuit.
5 REC
• Open circuit or loose connection between
➤
Circuits valid spider assembly and 5 REC (BUS A). BUS B ➤
Red Wire
➤
for • Open circuit or loose connection between White/Red 2 REC
Traction 5 REC and 2 REC. Wire
➤
➤
2 REC gate and PZ10 (white/red wire). White/Red
2 REC
➤
TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
STATUS CODE Excessive capacitor voltage when This status code will be displayed when capacitor
-51 motor current is high. volts exceed 225 volts and motor current is greater
than 300 amps.
POSSIBLE CAUSE F R
Excessive source inductance. S1 S2
Circuits valid • Tag lines without filters are being used. FIELD
for • Battery cables are too long.
F R
Traction A1
Controller High peak current in motor.
A1
ARMATURE
• Check for shorted field winding.
A2
• Check for shorted armature winding.
A2
SCR
➤
CURRENT ➤
SENSOR
➤
NEG
7-20
EV100ZX DIAGNOSTIC STATUS CODES
➤
YES Forward or reverse contactors open and T2
close, then can only be closed by opening
and closing the key switch.
F R
POSSIBLE CAUSE
Excessive source inductance. S1 S2
Circuits valid • Tag lines without filters are being used. FIELD
• Battery cables are too long. F
for R
Traction Defective 4 REC circuit.
• Check for shorted 4 REC. A1
Controller • Check for open circuit, or loose connection in ARMATURE
4 REC circuit. 3 REC
A2
Defective 3 REC circuit.
• Check for open circuit or loose connection in A2 4 REC
3 REC circuit.
SCR
➤
CURRENT ➤
SENSOR
➤
NEG
7-21
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Defective logic card.
• Replace logic card.
Circuits valid
for
Traction
Controller
POSSIBLE CAUSE A1
Reversed yellow and green current sensor wires.
Circuits valid • Insure that the green wire connects to PZ4
with no open circuits and that the yellow wire A2
for connects to PZ3 with no open circuits or
Traction loose connections. A2
Controller Reversed power cable connection.
• Insure that the battery positive cable connects SCR Green
PZ4
to SCR negative and the motor A2 cable con- CURRENT
SENSOR Yellow PZ3
nects to SCR A2.
➤
NEG
7-22
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Defective regenerative sensor input circuit.
• Check sensor wire #22 for open circuit or POS SENSOR 2
loose connection between sensor (welded ➤
Circuits valid connection) and PA4.
for
➤
Traction
Controller Wire Wire
7 REC
#22 #21
PA4 PA5
➤
TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
STATUS CODE Regenerative current sensor input This status code will be displayed when the input
-71 missing (wire #21). signal at PA5 is missing.
POSSIBLE CAUSE
Defective regenerative sensor input circuit.
• Check sensor wire #21 for open circuit or POS SENSOR 2
loose connection between sensor (welded ➤
Circuits valid connection) and PA5.
for
➤
Traction
Controller 7 REC
Wire Wire
#22 #21
PA4 PA5
➤
7-23
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Open connection in the PA6 circuit.
➤
• Check for open circuit of loose connection
➤
between PA6 and the A2 connection of the
Circuits valid RB contactor. RB COIL
7 REC
➤
for • Check for open circuit or loose connection
Traction between 7 REC and the A2 connection of the DRIVE
RB contactor. MOTOR PB2 PA6
Controller A2
17
RB CONTACTOR
TIPS
A2
POSSIBLE CAUSE
Defective RB contactor.
7 REC
➤
7-24
EV100ZX DIAGNOSTIC STATUS CODES
➤
POSSIBLE CAUSE
Defective RB contactor. RB COIL
Circuits valid • Check RB contactor for smoothness of 7 REC
➤
operation and excessive wear on moving
for parts. DRIVE
Traction MOTOR PB2 PA6
Intermittent PA6 input. A2
Controller • Check for loose connections in PA6 circuit
from PA6 to RB contactor A2 connection. 17
➤
for loose connection.
• Check coil connection from battery positive to
RB coil (+) for loose connection.
Circuits valid codes displayed that may more closely define the
failure mode. Trouble shoot per new status code.
for 1 REC turn off related to regen.
Wire Wire
Traction • Check for loose connections on all regen power 7 REC
➤
#22 #21
circuits from battery positive to RB contactor
Controller A2 connection. DRIVE
MOTOR PA4 PA5
• Check for loose connection on regen input circuits. PA6
• Wire #22 from sensor 2 to PA4.
• Wire #21 from sensor 2 to PA5.
• Wire #17 from RB contactor to PA6. 17
Defective motor circuit.
• Check motor circuit for open or loose connections. RB CONTACTOR
• Check motor brushes for proper seating. TIPS
F or R contactor power bouncing open. A2
➤
7-25
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Intermittent connection in battery power circuit.
LINE
Circuits valid • Check battery power circuit, both positive and BATTERY FUSE
CTR
negative for loose connections. CONNECTION
for CAPACITOR
➤
➤
BATTERY
contactors and etc., for possible opening
Controller during regen cycle.
BATTERY
Excessive source inductance. CONNECTION
• Check for unfiltered tag lines.
➤ NEGATIVE
• Check for long battery cables.
POSSIBLE CAUSE
Indicates Drive Motor has overheated and
thermostat switch is closed. TRUCK MANAGEMENT
Circuits valid MODULE (TMM1)
Other causes for status code: 1
for
• Terminal 1 is shorted to Negative.
Truck
• Defective input switch (shorted).
Management • Defective TMM card.
Module SW1
NOTE: When SCR Pump Control is used with
internal TMM function, input terminal is PA3 on
Pump Logic Card.
BATTERY ➤
NEGATIVE
7-26
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Indicates Pump Motor has overheated and
thermostat switch is closed.
BATTERY ➤
NEGATIVE
POSSIBLE CAUSE
Indicates Drive Motor Brushes have worn
through the sensing wires.
TRUCK MANAGEMENT
Circuits valid Other causes for status code: MODULE (TMM1)
85 6
10
for • Terminal 8 and 10 is shorted to Negative.
Truck • Defective input switch (shorted).
• Defective TMM card.
Management
Module SW8
SW5 SW10
SW6
NOTE: When SCR pump control is used with
internal TMM function, input terminal is PA4 and
PA5 on pump logic card.
BATTERY ➤
NEGATIVE
7-27
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Indicates Pump Motor Brushes have worn
through the sensing wires.
TRUCK MANAGEMENT
Circuits valid Other causes for status code: MODULE (TMM1)
11
5 6
12
for • Terminal 11 and 12 is shorted to Negative.
Truck • Defective input switch (shorted).
• Defective TMM card.
Management
Module SW11
SW5 SW12
SW6
NOTE: When SCR pump control is used with
internal TMM function, input terminal is PB1 and
PB2 on pump logic card.
BATTERY ➤
NEGATIVE
7-28
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Invalid card type selection.
• Review function 17 in the Handset Instruction
sheets. Adjust and set card type value as
Circuits valid instructed by Service Manual.
for
Pump Verify that the correct logic card catalog
number is installed in the controller.
Controller
7-29
EV100ZX DIAGNOSTIC STATUS CODES
➤
alternate between code 123 and code 124. T2
Complete checks for 124; if the problem is
not found, perform code 123 check.
➤
P
POSSIBLE CAUSE
Circuits valid Defective Pump contactor.
• Pump power tips fail to close because:
for 1) Welded normally closed power tips +
Pump 2) Binding contactor tip assembly
P
3) Defective Pump contactor coil
Controller 4) Incorrect pump contactor coil resistance.
5) Defective pump contactor coil snubber. A1 PB4
ARMATURE
(See status code 123)
A2
Open motor circuit.
• Check for open circuit or loose connection in
pump motor circuit from the A1 connection to
the A2 connection on the control panel. A2
Defective 1A contactor.
➤
• Perform checks as outlined in status 123. NEG
PUMP
CONTACTOR
➤
➤
7-30
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Open thermal protector circuit.
• Check for loose connection or broken wire
Circuits valid between:
Black
Black wire-Thermal protector and PZ1. PZ1
for Gray wire-Thermal protector and PZ5.
Pump THERMAL
Defective thermal protector. PROTECTOR
Controller • Disconnected wires from PZ1 and PZ5. At
PZ5
room temperature (25° C or 75° F) measure Gray
resistance between Black and Gray wire.
Replace TP if ohmic value is greater than
300 ohms.
POSSIBLE CAUSE
Open sensor wire circuit to PZ4.
• Check for loose connection or broken wire
(green wire) from current sensor to PZ4 on A2
Circuits valid the logic card.
for Green
SCR PZ4
Pump CURRENT
➤
Controller SENSOR
➤
➤
NEG
7-31
EV100ZX DIAGNOSTIC STATUS CODES
➤
adjustment.
POSSIBLE CAUSE
Open sensor wire circuit to PZ3. A2
Circuits valid • Check for loose connection or broken wire
(yellow wire) from current sensor to PZ3 on
for the logic card. SCR ➤
Traction CURRENT
SENSOR PZ3
Controller Yellow
➤
➤
NEG
➤
➤
7-32
EV100ZX DIAGNOSTIC STATUS CODES
➤
between 1 REC and PZ8 (white/blue wire).
• Check for open circuit or loose connection 2 REC
➤
between 1 REC (3 REC snubber) and PZ9
(blue wire).
Defective 1 REC.
• Intermittent or open 1 REC gate. Field test
22 REC
may or may not show defect. Replace 1 REC
after above checks show no problem found.
POSSIBLE CAUSE
➤
P
Defective 1 REC.
• Check for shorted 1 REC. ➤
1 REC
• Check for defective 1 REC insulator (co-therm)
Circuits valid that may short 1 REC heat sink to base plate. ➤
for Defective 1A contactor.
Pump • Check for welded 1A contactor power tips.
Controller ➤
➤
T2
P CONTACTOR
➤
PS2
7-33
EV100ZX DIAGNOSTIC STATUS CODES
➤
Defective 2 REC circuit. ➤
➤
Circuits valid • Check that 2 REC will gate on. 2 REC CHOKE
• Check for open circuit or loose connection T5
for between 2 REC gate and PZ10 (white/red wire). 1X
Pump • Check for open circuit or loose connection
1 REC and 1 C through the 2 REC circuit.
Controller Defective 5 REC circuit.
• Check for shorted 5 REC. 22 REC
➤
➤
• Check for shorted 5 REC snubber (25 REC)
5 REC
Open Choke (1X).
• Check for open circuit between T5 and T3. T4 T3
Ohm meter should read zero ohms.
➤
Pump contactor or power tips bouncing open.
• Check that Pump contactor power tips do not T2
bounce open during operation (ie: travel over 25 REC
speed bumps or dock plates).
• Replace 2 REC
A2
SCR
➤
CURRENT ➤
SENSOR
➤
NEG
7-34
EV100ZX DIAGNOSTIC STATUS CODES
➤
POSSIBLE CAUSE
PZ12 PZ14
Defective 5 REC circuit. White/Violet
Circuits valid • Check for shorted 5 REC.
➤
White/Violet Orange
➤
• Check for shorted 5 REC snubber (25 REC).
for • Check that 5 REC will gate on.
1X
CHOKE
Pump • Check for open circuit or loose connection 2 REC T5 Orange
➤
Wire 2 REC
between 5 REC gate and PZ12 5 REC REACTOR
Controller (white/violet wire). ➤
T4 T3 T5 T4
➤
T3
• Check 2 REC and 2 REC snubber (22 REC) REACTOR
for short circuit. 25 REC
• Replace 5 REC
➤
➤
1 REC
1C
T5 1X
2 REC
➤
7-35
EV100ZX DIAGNOSTIC STATUS CODES
➤
YES Pump contactors open and close, then can T2
only be closed by opening and closing the
key switch.
P
POSSIBLE CAUSE
Excessive source inductance.
Circuits valid • Tag lines without filters are being used.
A1
• Battery cables are too long.
for
Pump High peak current in motor.
• Check for shorted field winding. A1
Controller • Check for shorted armature winding. ARMATURE
A2
A2
SCR
➤
CURRENT ➤
SENSOR
NEG
A2
SCR
➤
CURRENT ➤
SENSOR
➤
NEG
7-36
EV100ZX DIAGNOSTIC STATUS CODES
POSSIBLE CAUSE
Defective logic card.
• Replace logic card.
Circuits valid
for P COIL
Pump
51 7
Controller
PB4 TB4
POSSIBLE CAUSE A1
Reversed yellow and green current sensor wires.
Circuits valid • Insure that the green wire connects to PZ4
A2
with no open circuits and that the yellow wire
for connects to PZ3 with no open circuits or
A2
Pump loose connections.
Controller Reversed power cable connection. SCR Green
• Insure that the battery negative cable connects
PZ4
CURRENT
to SCR Negative and the motor A2 cable SENSOR Yellow PZ3
connects to SCR A2.
➤
NEG