You are on page 1of 12
USER MANUAL For UNINTERRUPTIBLE POWER SUPPLY IGBT Series NUMERIC POWER SYSTEMS LIMITED “NUMERIC HOUSE”, No. 5, Sir. P. S. Sivasamy Salai, Mylapore, Chennai - 600 004. NUMERIC EDITION 1, Copyright MARCH 1999. The information contained inthis marualis subject to change without notice NUMERIC shall not be liable for errors contained herein or for incidental or consequential damages in connection with the ‘uimshing, performance, or use of tis Mangal No part of thismanual may be photocopied, reprdaced either in full orn part without theprior wtitten consent of NUMERIC, Page No, 7 Numeric UPS USER MANUAL PREFACE " Congratulations, on having purchased @ Numeric Uninterruptible Power Supply, which can supply and protect your inioro computer item poworcisturbanoss of various kinds Before you begin (instal the UPS, please read this manual thoroughly. The warranty of this product wil be vodifitis abused. This marual provides general information regarding instalation, operation and connection of Uninterruptible Power ‘Supply, NOTICE: & The confonts ofthis mania are bound to change without prior notoa, We cannot assume responsiiliy for errors in this manual or consequences thereo!, However should any error be datacted, we would be gratatulityou could inform us. TABLE OF CONTENTS Page 4. Location of Controls 2 Useof Controls 3. Mimic Diagram 4 Operating Modes 5. Site Preparation & Safety Procautions 7 Operating Procedure 8 Trouble Shooting Guide 9. Precautions When in Use 10. Techical Specifcation ti, Do's and Don'ts 12, Notes UPS S, No: i USER NANUAL Numerie UPS Page No. 2 FRONT PANEL LOCATION OF CONTROLS LOCATION OF CONTROLS - FRONT Mr 5 nome? (_] pt}—s iiaveine 2. Inverter Control 3. Stat Switch & | 4, Stop Swich 5 Digital Meter to see Cutput Vollage, Current and Frequency & Melt Selector Switch REAR PANEL Pp « F LOCATION OF CONTROLS - REAR + \ al 7. Rotary Switch 8 Cutput Socket ln a. ee oe Page Wo, 3 Numeric UPS USER MANUAL USE OF CONTROLS 1, MIMIC PANEL Provides information on status of various modes of operations of UPS. 2, INVERTER CONTROL Enables DC power source to various contral functions including stertsiop of Inverter 3. START + The inverter is switched cn whan this button is activated. | 4 stop + The inverter is switched off when this button is activated, 5, SINGLE WINDOW DIGITAL METER + This moter reads Output Voltage, Currant and Frequency. 6, METER SELECTOR SWITCH : This switch solects Output Voltage or Current or Frequency, 7, ROTARY SIMITCH + This switch is used to select UPS power (normal mode) or mains power (maintenance mode). 8, OUTPUT SOCKET + Ouiput socket provides AC power of the UPS to the load MIMIC DIAGRAN O-* " 445 4. MAINS ON Green lamp. + This lamp is on whon mains uty power is avalable in the UPS, 2, GONVERTOR ON- Green lanip. : Thislempis.on when the convertris functioning normaly and DC power is avalabe. 3. BACK UP - Orange lamp. “This lamp turns on when mains uty or convertor has fale, inverter is powered by the battery, 4, DC HIGH- Red lamp. ‘This lamp flashes and comes on whan DC voltage ftom charger exceeds charging frit. USER MANUAL Numeric UPS Page No 4 5, LOW BATTERY - Red lamp. 6, INVERTER ON- Green lamp. 7. INVERTER TRIP - Fed lemp, 8, LOAD ONUPS- Green lamp. 8, OUTPUT HIGH - Red lar. 40, OUTPUT LOW - Red lamp. 11, OVERLOAD - Red lamp, 12, LOAD ON BYPASS - Red famp. This lamp flashes with a beep to indicate end of battery autonomy, or wwoak battery Thi jamp glows when the inverter isin normal operating conditions, This lamp glows when the inverter has tippad due to en anvomaly This lamp glows whan the power is available to load fram tho UPS. This lamp glows when the UPS output voltage has exceeded 250 volts RMS and inverter tripped This lamp glows whan the UPS ouput voltage has gon below 180 volts RMS and inverter tripped. This lamp glows whan the UPS load capacity is exceeded and the UPS has tippod | This lamp glows when the power Is avaiable From the mains dracty. {Load unprotected) OPERATING MODES NORMAL OPERATION: During normal operation of UPS, the load is supplied from, the mains through the convertar and inverter, The converter also supplies the current for charging and tmaintsning the batery in a fully charged siale DURING MAINS FAILURE: \When the mans voltage is not present or is outside the allowed tolerances, the battery supplies the inverter During this phase the battery discharges (this will be indicated on the UPS front pane) and maintains te load ‘on the inverie’ asin rirmal operation. The standby time: available depends both on the cepacity of the instated batery and on the capacity oftheload,isrecommended to uilize this backup time for oritoal loads, reduce the ‘pon-ofiticl loads and switch off the unimportant loads, WHEN MAINS SUPPLY RESUMES: When the mains supply resumes (within th ellowed iris) the UPS reluins automatically to the normal mode of operation as previously desciibed. The converter now slarts to recharge the battery as well as supply power to the inverter In the mean time any futher maine fare willrosull in reduced standby back up time, verse A] —> ba aes stein Flat Ohaige Batory = Tt Normal Operation ovo > boat During Mains Faiture —> bat Page No. 5 Numeric UPS USER MANUAL SITE PREPARATION 4. A separate location, used only by authorised personnel, is required fo be provided fer UPS installation, 2, Thelecation should be neal and clean, ree from pclluton, 3. Proper Switchgear and Cabling according to KVA of the UPS should be provided atthe site in consultation | wth Numette. Exhaust fans should be provided in case there is no cross ventilation facilty Adodicatod ‘earth pt’ is to be provided atthe ste for UPS, For mora information, ccntact Numeric Ensure thal the building earth (already existing) is properly connected and potential tree Ideal location for the sealed maintenance-free battary is an air-conditioned atmosphere below 25'C for optimum performance SAFETY PRECAUTIONS 41, IMs essenta that al safety precautions are observed. Installation and maintenance of the aquiprant and batteries should only be undertaken by NUMERIC SERVICE ENGINEERS ! 2, The batery terminals are LIVE AT ALL TIMES, A short clu, anon dscharged balay or baitery cells wily result in @ high current low which can demage the battery and battery cables and cause injury and fe \ 3. Use cnly insulated tools, 4, Before working on the battery oF baltery cel, ensure that itis fuly isolaied by removing the battery fuses. lerminations or inks 5. Donot place toois or other ccnductive objects on the battery 6 Ballary Flectolyle Contact , The Eyes: Irigaie the eyes with saline soluion. If saline soliton is not evalable, wash the eye with ‘lean running water for atleast 10 minutos b. The Skin: Wash the area wih plenty of clean running water, tamove any contaminated clothing and cover the affected area with dry sterile gauze OPERATING PROCEDURE ‘Steps for switching on Siep 1: Switch on Mains Usity power, Observe (switch on input MCB ifprovided) fr Maine on and corwerior comlamp to glow, Slap 2: Switch on inverter contrel (observe various lamp on mimio panel) Siep 3: Prass Slat button (observe inverter on ndicator to glow and AC output voltmeter to display voltaga) Sep 4; Allow two minutes for system to stabilise, Then switch on load, (fF oulput MCB is provided, switch cn) NOTE: The changeover switch provided in the back panel, should always be kept in UPS supply mode, Observe for load on UPS indication. USER MANUAL Numeric UPS Page No. 6 ‘Steps for switching off CAUTION : ENSURE ALL USERS ARE INFORMED PRIOR TO SWITCH OFF| Step 1; Switch offload (in case output MCB is provided, switch of. Slop 2; Prassinverter stop button, Stop 3: Switch off invarter contra, Step 4: Switch off mains utily power: (In case input MCB Is provided, switch off, [ NOTE: Keep the AC inpul on always to charge tho baltaries, TROUBLE SHOOTING CHART FOR USER INDICATION STATUS CAUSE REMEDY Mains On Off Mains Fei Check UPS Input Charger Off Due to Mains talure or Check Mains Input, replace sultablo fuse i town, due to card failure Low battery On Ballory bank volage Disconnect load and sivtch of inverter. Keop DC Low (Red) below cut-off init Charger On. Battories may neod service! replacement 1 problem persisis, cal Numeric Servic, DC Overveltage = On Due to card failure Call Numeric Service Centre ‘AO Overvoltage —On,—_4. Wrong Voltage Setting Call Numerio Service Centre. (Output) ‘AC Undervoltage On DC Input low or (Check load and switch on Inverter, (Output) Overload Output Overload On Dutput Overload ‘Check load, switch on Inverter and load systems Short Circuit cons by one, Note : trespective of the nature of the faut, inform NUMERIC. PRECAUTIONS WHEN IN USE % Keep al leas! 1 foot clearance from venslaton holes on bo sdes of the metal case. Never open up the metal case, There Is no user serviceable partsincide. in case of failure, call Numeric Service only, © Replace blown fuses with same rating only, both on ulilty and load sides. & Batteries should be handled as por battery manufacturers’ specications. Pago No. 7 Numeric UPS USER MANUAL ENVIRONMENT = * |] 4 D0 not use strong volatlo agents euch as benzane, freon cr thier fo clean the surface. Uso a plecs of dry clot only. 4 Dornot operate or store UPS outdoor. 4 Do not place or shift the UPS where the location is néar dusty or hol environment 4 Do not place UPS under strong vibration. 4 Do not apply heavy shock or drop the system suddenly cn to the floor NOTE This UPSs desiared for computer and computer peripherals only. ts not designed to support other kinds of acs, the connection of which may cause damage fo the oad, and the manufacturer wll not be responsitie forthe compilasise of any specticaion writen in this manuel with regerds fo such bads. ‘fan AC stabiteor is used in the computer system, itshould be connostad tothe by-pass of the UPS for salely reasens, When you leave your work for the day, His advisable fo turn off the inverter, which may dein battery for @ overnight power falure, TECHNICAL SPECIFICATION Copaciy OS WA 14va 2KvA 3KVA iva VA up Powor (VA) 00 1000 7000 000 4000 000 AG laput No. of Phases 1 1 1 1 av ant Veltage (Vy DWV415% OVI PETE IOVS 15% OVENS 250 15% Froquenoy (2) ws6% Desh «806% HEE = BDL 502 6% Do Vals ¥) ee ABV TRV T2VAt4AVY 9B V-t4ave 120 V-1g2V" AC Output No.of Phasos 1 1 1 1 1 1 Voltage (\) 2OVatK «DVI — VAM —-DVN% — IOV «HOV, Frequency (42) poti% Sete 01 SETH SOT 02 1% Emiiency 780% 00% 2% 280% > 80% 780% | Waxetomn ‘Sinsvidal Sinscdal Sinusoidal -—‘Sinucndel—Sinuseeal—_—Siueidal | = HamorieDistoton ——<5% 8% <5 <5 «8% Bs Environment OeEO'C —O*LOSDTC OOPS OSU BUD MathodotCooling Fora Ar = Forted Air «= Fowcedi Air «= ‘Forced Air = Feread air Foraedi ir Electronic Protection for- Do Low Yes Yes Yes Yes Yes Yes Output Low Yes Yos Yes Yes Yes Yes ulput High Yes Yes Yes Yes Yor Yee Over Gumert ss Yes Yes Yes Yes Yes Dimension ain ba neater ot vont Genter ht Refer the annexure forthe appopriate modeled in the Locaticn of Contiols Section * Custom Bull fo Customer's choice. Specifications are subject to change witout prior natice Page Wo. 7 Numeric UPS USER MANUAL ENVIRONMENT = * | © Do notuse strong volatile agents such as benzene, freon or thinner to clean the surfa 30 a place of dry cloth only, + Denot opatate ot store UPS outdoor. + Dont place or shift the UPS wire the location is near dusty or hot environment. @ Do not place UPS under strong vibration. Do nol apply heavy shock or drop the systam suddenly on lo the floor. NOTE This UPS is designed for computer end computer peripherals only. itis not cesigned to support other kinds offoads, the Connection of which may cause damage fo the load, and the manufacturer wil not be responsible forthe cempliance of any specificaton writen in this manual with regards to such loads. Wan AC slabifsoris used in the computersystom, # should be connected tothe by-pass ofthe UPS for safety reasons. When you leave your work for the day, tis advisable to turn of the inverter, which may drain battery for a overnight power failure. TECHNICAL SPECIFICATION Capaniy 5 kVA 1A kVA iva 4KvA SkvA COurput Power (vA) 500 ‘00 200 000 4000 5900 | AG Input No. of Phases 1 1 1 1 uw ar Vollage (V) TBDV#15% «BW VFIS% OVS IS OVENS 230V21S% 230Ve 16% Frequency (Hz) 50+ 6% 506% De b% 502 6% 26% 46% DC Vols (vy) 2443" AVIA TOV-AMAVE V4 SBA 12092" AC Output No.of Phases 1 1 1 1 1 1 ‘Voltage (V/) 20V 81% 20V21% POV 21% BOVAI% WOVst OVE Frequency (Hz) 50 1% 021% 21% 502 1% 021% 041% Efclenay >60% 60% 00% 280% 280% 80% Waveform ‘Sinusoidal ‘Sinueoidel ‘Sinusoidal ‘Sinusoidal ‘Sinusoidal ‘Sinusoidal Hanmonic Distortion

You might also like