P= 55.5 kN P= 55.

5 kN

t1 = 6 mm t1 = 6 mm
t2 = 18 mm t2 = 18 mm
g= 0.5 mm g= 0.5 mm

Dpin = 17 mm Dpin = 16 mm

Material: Ta64 Material: 17-4ph steel


Ftu = 160 ksi Ftu = 190 ksi
1103 MPA 1310 MPA
Fsu = 75 ksi Fsu = 114 ksi << 60% Ftu according to manufa
517 MPA 786 MPA

Bending: Bending:
Mmax = 208125 N.mm Mmax = 208125 N.mm

Ipin = 4100 mm4 Ipin = 3217 mm4

Sbending = 431 MPA Sbending = 518 MPA

Shear: Shear:
Apin = 227 mm2 Apin = 201 mm2

Sshear = 122 MPA Sshear = 138 MPA

Shear + Bending interaction: Shear + Bending interaction:


Rb = 0.39 Rb = 0.40
Rs = 0.24 Rs = 0.18

RF = 2.19 RF = 2.31
< 60% Ftu according to manufacturer
Dyneema DM20 Rig Max preload = 25000
2548.41998

Rope diameter = 12
Rope stress = 221

Stretch = 0.00263

Rope length (m) Stretch (mm)


4 26.8
5 33.5
6 40.2
7 46.9
8 53.6
9 60.3
10 67.0
12 80.4
14 93.8
15 100.5

Rope modulus = 33
Min tensioner length:
Thread min length = 20
Cable stretch = 100.5
Margin = 50

Tensionner length shall be between 150 to 200 mm


N << TBD T12 Technora rope
kgf

mm
MPA

mm/mm/1000kg

GPa << calculated with above data

mm per side (should be at least equal to thread diameter)


mm
mm for tuning allowance

ll be between 150 to 200 mm