MAINTENANCE MANUAL AS532MK1

General - Inspection / Check


601 System inspection
A. References
24-00-00-301 ................................. General instructions
24-21-00-401 ................................. Alternator: Removal - Installation
24-30-00-602 ................................. Check for corrosion of connectors of master box
protection boards
20-07-03-408 MTC
24-00-00 MCS
B. Special Tools

ICO 94.33.00.01.30 ...................... play measuring device

C. Consumable Materials

None

D. Routine Replacement Parts


None

E. Preliminary steps

REFER TO GENERAL INSTRUCTIONS ON


24-00-00-301 AND THE GENERAL VISUAL
SHECKIND PRINCIPLES FOR ELECTRIC AND
ELECTRONIC SYSTEMS (INCLUDING THEIR
PROTECTION) WITH RESPECT TO THE FLIGHT
CONTROL LINKAGES AND COMPONENTS, THE
FLUID SYSTEMS INSTALLED ON THE AIRCRAFT
AND TO THE STRUCTURAL COMPONENTS.

F. Alternator
Figure 601

(1) Open the sliding cowling.


(2) Check that cables are properly connected and securely attached.

(3) Check that screws is tightened and locked.

(4) Check:
(a) that power connector is locked in place,

(b) that ventilation screen is clean,

Conf. Code: 500 24-00-00-601 Page 601


2013.07.18
MAINTENANCE MANUAL AS532MK1

(c) condition of cable leads,

(d) attachment of alternator cable harness,


(e) alternator attachment to MGB.

NOTE

Check the alternator attachment by mounting a dial


gauge on the MGB with the feeler bearing on the end
of the alternator.

Check that the dial gauge reading does not change


(i.e. no play) when upward and downward loads "F"
of 20 daN (44.962 lbf) are applied manually on the
alternator.

If play is observed, remove the alternator as per


24-21-00-401 to check internal bearings (refer to
manufacturer’s literature).

(5) On alternator covers (POST MOD 0723080), check:


(a) attachments (screws, washers, nuts) for condition,

(b) supports (for cracks, dents; paintwork),

(c) cover (paintwork ; for cleanliness, cracks, dents, and loose or missing rivets).

G. Cockpit overhead panels (control and display)


(1) Unlock and open panels.
(2) Check power connectors (attachment, condition of wiring).

(3) Examine rear face of panels. Close panels.

(4) On front face, check condition and attachment of the following:


(a) switches and selectors,

(b) voltmeters and ammeters,

(c) indicator lights (carry out functional test with power on),
(d) snap wire on switches on "EMERGENCY CUTOFF" bar.

(5) Close and lock panels.

H. Electrical master boxes


(1) Electrical master boxes 1 ALPHA and 11 ALPHA

(a) Open access panel to electrical master box.


(b) Check box attachment to structure.

(c) Remove cover from master box.

(d) Check :
1 attachment of components and cable looms,

Conf. Code: 500 24-00-00-601 Page 602


2013.07.18
MAINTENANCE MANUAL AS532MK1

2 wiring for proper connection and tightening,

3 condition of cables and sheaths,


4 condition of bonding braids.

(e) Check that all circuit-breakers are engaged.

(2) Electrical master box 1 ALPHA


(a) Check the PCBs for corrosion : replace any defective component.

(b) Install electrical master box cover and close access panel.

(c) If corrosion is detected on the electrical master box PCBs, comply with
24-30-00-602.

I. Circuit-breaker panels
(1) Check all circuit-breakers for condition, attachment and engagement.
(2) Check identification plates for cleanliness and condition (cracks, chipping).

(3) Open the circuit breaker panels.

(4) Check condition of wiring and connections.

J. Electrical rack components


(1) Open electrical equipment bay inspection panels.
(2) Check :

(a) components for condition and attachment,

(b) the condition of the shelves (no cracks, impacts, corrosion).


(c) electrical connectors for condition and locking,

(d) wiring for proper connection and tightening,

(e) condition of cables and sheaths.

In particular, check the routing and clearance of the harnesses with respect to
the structure and adjacent equipment items, in the area behind the transformer
rectifiers, and to the PCB rack.

(f) condition of bonding braids and grounding terminals.

(3) Close electrical equipment bay inspection panels.

K. External power receptacle


(1) Open the external power receptacle door.
(2) Check :

(a) condition of door (cracks, corrosion) and retaining springs,

(b) condition of receptacle housing (loose rivets, cracks, corrosion),


(c) screws securing receptacles to housing,

Conf. Code: 500 24-00-00-601 Page 603


2013.07.18
MAINTENANCE MANUAL AS532MK1

(d) receptacles and blast with compressed air.


(3) Inside cabin, remove lower LH panel from electrical rack :

(a) remove cover from external power receptacle circuit board,

(b) check attachment and cleanliness of lugs on receptacle terminals,


(c) check condition of diodes and wiring,

(d) install cover on circuit board.

(4) Install lower LH panel in electrical equipment bay.

L. Main battery
(1) Check the general condition and the attachments:
(a) of the battery tray assembly,

(b) of the vent pipes,

(c) of the temperature probe connection.

M. Standby battery
(1) Check condition and attachment of tray.
(2) Check wirings and connector for condition.

(3) Check knurled knobs for tightening.

(4) Check housing for cleanliness.


(5) On sub-panel 34 ALPHA, check that "STBY-FORCED" switch snap wire is installed.

Conf. Code: 500 24-00-00-601 Page 604


2013.07.18
MAINTENANCE MANUAL AS532MK1

Figure 601

Conf. Code: 500 24-00-00-601 Page 605


END OF MODULE 2013.07.18
Conf. Code: 500 24-00-00-601 Page 606
2013.07.18