1. Reason for the Job
You must not do this task directly and independently from another deactivation task to dispatch the aircraft
under MMEL or CDL. Refer to and do first the applicable AMM deactivation task which refers to this task.
2. Job Set-up Information
QT
REFERENCE DESIGNATION
Y
No specific 1 ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific AR WARNING NOTICE(S)
No specific Torque wrench: range to between 0.306 and 0.374 m.daN (27.08
and 33.10 lbf.in)
B. Consumable Materials
REFERENCE DESIGNATION
CPNCL00338 MASTINOX D40
D. Referenced Information
REFERENCE DESIGNATION
3. Job Set-up
SUBTASK 78-30-00-941-091-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less
than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(2) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
SUBTASK 78-30-00-010-097-A
B. Get Access
(1) Open the fan cowl doors Ref. AMM TASK 71-13-00-010-803:
(a) FOR 4020KM1 (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR 4020KM2 (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position under the left fan cowl door.
4. Procedure
SUBTASK 78-30-00-040-075-A
A. Deactivation of the Thrust Reverser
(1) Hydraulic inhibition:
Ref. Fig. Hydraulic Deactivation of the Isolation Control Unit (ICU)
(a) Remove the tethered pin (3) from the aft hole (5) of the inhibition lever (1).
(b) Move the inhibit lever (1) against the inhibit plunger (4).
(c) Check that "ICU INHIBITED" is now visible.
(d)
Install the tethered pin (3) through the forward hole (6) in the ICU (2) and the inhibit lever
(1).
(2) Mechanical inhibition:
(a) Installation of the inhibition secure pin (1):
Ref. Fig. Mechanical Pin from Storage Bracket
1 Removal of the inhibition secure pin (1) from the storage bracket:
a Remove the screw (2), cover (3) and inhibition secure pin (1).
b Put the cover (3) back in position.
c Install the screw (2).
d TORQUE the screw (2) to between 0.306 and 0.374 m.daN (27.08 and
33.10 lbf.in).
(b) Installation of the inhibition secure pin (1) in the inhibition hole on the lower beam (4):
Ref. Fig. Mechanical Pin on the Lower Beam
1 Remove the screw (2) and the inhibition cover (3).
2 Install the inhibition secure pin (1) in the hole on the lower beam (4).
3 Put the inhibition cover (3) back in position.
4 Apply MASTINOX D40 (Material Ref. CPNCL00338) on the thread of the screw (2).
5 Install the screw (2).
6 TORQUE the screw (2) to between 0.306 and 0.374 m.daN (27.08 and 33.10 lbf.
in).
5. Close-up
SUBTASK 78-30-00-410-080-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors Ref. AMM TASK 71-13-00-410-803:
(a) FOR 4020KM1 (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR 4020KM2 (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Figure 78-30-00-991-92400-03-A (SHEET 1/2) - Hydraulic Deactivation of the Isolation Control Unit (ICU)
** ON A/C FSN 426-499, 516-600
Figure 78-30-00-991-92400-03-A (SHEET 2/2) - Hydraulic Deactivation of the Isolation Control Unit (ICU)
** ON A/C FSN 426-499, 516-600