C

AIRCRAFT MAINTENANCE MANUAL


CRJ200

**ON A/C 7003−7007, 7009−7010, 7015−7016, 7019−7020, 7023−7025, 7032, 7041, 7053, 7057,
7059, 7061, 7063−7064, 7070, 7073, 7075−7076, 7081, 7084−7086, 7088, 7090, 7093−7094,
7099, 7103−7104, 7106, 7108, 7110, 7113−7115, 7119, 7121−7122, 7125, 7128, 7130, 7133,
7135−7136, 7140, 7142−7143, 7147−7148, 7152−7154, 7161−7162, 7165−7167, 7170, 7176,
7190, 7198, 7200−7201, 7205, 7219−7223, 7234, 7237, 7248−7249, 7252, 7262, 7266, 7272,
7282−7283, 7296, 7298−7299, 7301, 7320−7321, 7323, 7329, 7332, 7338, 7343, 7345,
7350−7351, 7365, 7371, 7373, 7375, 7377−7378, 7384, 7386, 7389, 7391, 7393−7394, 7403,
7407, 7413, 7419, 7430−7431, 7434, 7436, 7439, 7442, 7449, 7453, 7455, 7459, 7464, 7466,
7469, 7478, 7480, 7486, 7493−7494, 7499, 7514, 7529, 7547, 7556, 7563, 7567, 7570, 7573,
7583, 7591, 7605, 7607, 7617, 7619, 7622, 7625, 7629−7630, 7661, 7910, 8119−8400 and ON
A/C 7862, 7864 (Pre K601R50206 and Pre SB601R−31−036) and ON A/C 7008, 7011−7014,
7017−7018, 7021−7022, 7026−7031, 7033−7040, 7042−7052, 7054−7056, 7058, 7060, 7062,
7065−7067, 7069, 7071−7072, 7074, 7077−7080, 7082−7083, 7087, 7089, 7091−7092,
7095−7098, 7100−7102, 7105, 7107, 7109, 7111−7112, 7116−7118, 7120, 7123−7124,
7126−7127, 7129, 7131−7132, 7134, 7137−7139, 7141, 7144−7146, 7149−7151, 7155,
7157−7160, 7163−7164, 7168−7169, 7171−7175, 7177−7189, 7191−7197, 7199, 7202−7204,
7206−7218, 7224−7233, 7235−7236, 7238−7247, 7250−7251, 7253−7261, 7263−7265,
7267−7271, 7273−7281, 7284−7295, 7297, 7300, 7302−7319, 7322, 7324−7328, 7330−7331,
7333−7337, 7339−7342, 7344, 7346−7349, 7352−7364, 7366−7370, 7372, 7374, 7376,
7379−7383, 7385, 7387−7388, 7392 Pre SB601R−31−023 and ON A/C 7401, 7405 Pre
SB601R−31−028 and ON A/C 7700, 7705−7706, 7732, 7738, 7746, 7785, 7851, 7866,
7901−7902, 7915, 7950, 7973, 7975, 7981, 7984, 7989−7990, 8008, 8010 Pre SB601R−31−036
RECORDER, DIGITAL FLIGHT−DATA − REMOVAL/INSTALLATION

1. General
A. The maintenance procedures that follow are for the removal and installation of the digital
flight−data recorder (FDR). The digital FDR is installed in the aft equipment compartment
at FS755.

TASK 31−31−01−000−801
Removal of the Digital FDR

1. Job Set−Up Information


Subtask 31−31−01−946−001
A. Reference Information
REFERENCE DESIGNATION
TASK 24−00−00−910−801 Electrical/Electronic Safety Precautions
TASK 31−31−05−000−801 Removal of the ULD

Master
EFFECTIVITY: See Pageblock 31−31−01 page 401
31−31−01 Page 401
Dec 10/2020

Print Date: 2021-03-25


C
AIRCRAFT MAINTENANCE MANUAL
CRJ200

2. Job Set−Up
Subtask 31−31−01−910−001
WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO MAINTENANCE ON
OR NEAR ELECTRICAL/ELECTRONIC EQUIPMENT. IF YOU DO NOT DO THIS,
YOU CAN CAUSE INJURIES TO PERSONS AND/OR DAMAGE TO THE
EQUIPMENT.
A. Obey all the electrical/electronic safety precautions (Ref. TASK 24−00−00−910−801).

Subtask 31−31−01−865−001
B. Open, safety, and tag the circuit breakers that follow:
CB PANEL CB NO. NAME ZONE
CBP−1 C9 FLIGHT REC PWR 221
CBP−1 K2 FLIGHT REC CONT 221

Subtask 31−31−01−010−001
C. Open the access door that follows:
ACCESS DESIGNATION
311BB Aft equipment compartment door

3. Procedure
Subtask 31−31−01−020−001
Refer to Figure 401.
A. Remove the digital FDR (2) as follows:
(1) If mounting tray (3) has wing nuts (1), do as follows:
WARNING: WEAR EYE PROTECTION WHEN YOU CUT LOCKWIRE. WHEN
LOCKWIRE IS CUT, PIECES OF IT CAN HIT YOUR EYES AND
CAUSE INJURIES.
(a) Remove and discard the lockwire from the wing nuts (1) on the front of the
mounting tray (3).
(b) Release the two wing nuts (1) that hold the FDR (2) to the mounting tray (3).
(2) If the mounting tray (3) has locknuts (1), do as follows:
(a) Loosen the locknuts (1) on the front of the mounting tray (3).
(3) Carefully pull the digital FDR (2) from the mounting tray (3). Do not lift the digital
FDR (2) until it is clear of the electrical connector (4). Remove the digital FDR (2).
(4) Install protective caps on the mounting tray (3) and the digital FDR electrical
connector (4).
(5) When you replace the digital FDR (2), if necessary, remove the underwater locator
device (ULD) from the digital FDR (2) (Ref. TASK 31−31−05−000−801).

Master
EFFECTIVITY: See Pageblock 31−31−01 page 401
31−31−01 Page 402
May 10/2019

Print Date: 2021-03-25


C
AIRCRAFT MAINTENANCE MANUAL
CRJ200

FS755.00

FS755.00 1

A
WL111.15

LEGEND ram3131014_001.cgm, mb/cs, aug27/2018

1. Wingnut/Locknut.
2. Digital flight data recorder.
3. Mounting tray.
4. Electrical connector.
N1217

Digital Flight−Data Recorder − Removal/Installation


Figure 401

Master
EFFECTIVITY: See Pageblock 31−31−01 page 401
31−31−01 Page 403
May 10/2019

Print Date: 2021-03-25


C
AIRCRAFT MAINTENANCE MANUAL
CRJ200

TASK 31−31−01−400−801
Installation of the Digital FDR

1. Job Set−Up Information


Subtask 31−31−01−944−001
A. Consumable Materials
REFERENCE DESIGNATION
05−004 Lockwire, corrosion−resistant steel, 0.032 in. (0.81
mm) diameter composition 302 or 304
(MS20995C32)

Subtask 31−31−01−946−002
B. Reference Information
REFERENCE DESIGNATION
TASK 31−31−01−710−801 Operational Test of the Digital FDR
TASK 31−31−05−400−801 Installation of the ULD

2. Job Set−Up
Subtask 31−31−01−860−014
A. Make sure that the aircraft is in the same configuration as in the removal task.

3. Procedure
Subtask 31−31−01−420−001
Refer to Figure 401.
A. Install the digital FDR (2) as follows:
(1) If you replaced the digital FDR (2), install the ULD if necessary (Ref. TASK
31−31−05−400−801).
(2) Remove the protective caps from the mounting tray (3) and the digital FDR
electrical connector (4).
(3) Put the digital FDR (2) on the mounting tray (3). Carefully push the digital FDR (2)
into the mounting tray (3) to engage the electrical connector (4).
(4) If mounting tray (3) has wing nuts (1), do as follows:
(a) Set the two wing nuts (1) in front of the mounting tray (3) to engage the FDR
mounting−tray projections. Tighten the wing nuts (1).

Master
EFFECTIVITY: See Pageblock 31−31−01 page 401
31−31−01 Page 404
May 10/2019

Print Date: 2021-03-25


C
AIRCRAFT MAINTENANCE MANUAL
CRJ200

WARNING: WEAR EYE PROTECTION WHEN YOU CUT LOCKWIRE. WHEN


LOCKWIRE IS CUT, PIECES OF IT CAN HIT YOUR EYES AND
CAUSE INJURIES.
CAUTION: DO NOT USE THE LOCKWIRE AGAIN AFTER ITS REMOVAL.
USED LOCKWIRE CAN BE WEAKER WHEN IT IS REMOVED.
WEAK LOCKWIRE CAN BREAK AND CAN RESULT IN DAMAGE
TO THE EQUIPMENT.
(b) Safety the wing nuts (1) with lockwire.
(5) If the mounting tray (3) has locknuts (1), do as follows:
(a) Tighten the locknuts (1).

4. Close Out
Subtask 31−31−01−865−002
A. Remove the tags and close the circuit breakers that follow:
CB PANEL CB NO. NAME ZONE
CBP−1 C9 FLIGHT REC PWR 221
CBP−1 K2 FLIGHT REC CONT 221

Subtask 31−31−01−710−001
B. Do the operational test of the digital FDR (Ref. TASK 31−31−01−710−801).

Subtask 31−31−01−410−001
C. Close the access door that follows:
ACCESS DESIGNATION
311BB Aft equipment compartment door

Subtask 31−31−01−941−001
D. Remove all the tools, equipment, and unwanted materials from the work area.

Master