FAULT ISOLATION MANUAL
CRJ200
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 101
Jul 22/2001
2 21
Do an engine start (AMM Do an Operational Test of the
TASK 71−00−00−868−806). applicable IDG
On the Electrical Power 1G20EZ(2G20EZ). Refer to
Services Panel, set the NO the operational test of the
GEN 1(2) switch S1XA left IDG (AMM TASK 24−11−
(S6XA) to OFF/RESET, and 01−710−801). Refer to the
then to ON. Monitor the AC operational test of the right IDG
ELECTRICAL synoptic−page.
(AMM TASK 24−11−01−710−
Is the EICAS message
802).
GEN 1(2) OFF shown?
YES 12
Do an engine shutdown 22
(normal) (AMM TASK 71−00− Replace the applicable GCU
3
868−807). Set the GEN 1(2) 1A1XA(2A1XA). Remove the
On the AC Electrical YES switch S1XA(S6XA) to the YES
GCU (AMM TASK
synoptic−page, is the voltage ON position. At the GCU plug 24−11−07−000−801).
for GEN 1(2) 0 V? 1P10XA(2P10XA) is there Install the GCU (AMM TASK
continuity between the pins 32 24−11−07−400−801).
NO
and 39 and also between the
pins 32 and 40?
NO
13
rfi2410001_003(1).dg, kms/mr, Jan10/2010
23
On the plug J16(J17), on the
NO Replace the GEN 1(2)
Electrical Services Panel,
is there continuity between switch S1XA(S6XA)
the pins U and V? (WDM 24−21−00).
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 102
Feb 10/2011
FROM SHEET 1
CRJ200
24
Replace the LH (RH) ENGINE
FIRE PUSH switch/light
14 (SDS1WF (SDS2WF)). Refer
On the plug (J13 (J60)), on to the removal of the engine
the glareshield, is there NO fire push switch/lights (AMM
continuity between pins HH TASK 26−21−01−000−801).
and GG (WDM 24−21−00)? Refer to the installation of the
engine fire push switch/lights
(AMM TASK 26−21−01−400−
801).
TO SHEET 1
(BLOCK 2)
4 25
On the AC ELECTRICAL Replace the applicable IDG
synoptic−page, is the voltage (1G20EZ (2G20EZ)). Refer to
for GEN 1 (2) between 100 V NO the removal of the IDG (AMM
and 125 V and the frequency TASK 24−11−01−000−801).
between 375 HZ and 425 HZ? Refer to the installation of the
IDG (AMM TASK 24−11−01−
YES
400−801).
26
Replace the applicable GCU
(1A1XA (2A1XA)). Refer to the
removal of the CGU (AMM
TASK 24−11−07−000−801).
Refer to the installation of the
GCU (AMM TASK 24−11−07−
400−801). rfi2410001_004.dg, gd/ik, 09/10/01
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 103
Nov 29/2001
PREREQUISITES
CRJ200
EICAS LOGIC
IDG 1 (2) Low IDG oil−pressure signal
ELECT PWR (AMM 24−00−00)
(C) or a high IDG oil−temperature
EICAS (AMM 31−41−00)
signal is transmitted to the
DCU with an IDG 1 (2)
voltage>0.6 Vac and a left
(right) N2>9%
1 21
If the IDG found disconnected, Replace the applicable IDG
set the IDG disconnect NO
1G20EZ (2G20EZ). Remove
mechanism (AMM TASK the IDG (AMM TASK
24−11−01−710−805). Can the 24−11−01−000−801). Install a
IDG disconnect mechanism new IDG (AMM TASK
be set? 24−11−01−400−801).
YES
2 11
22
Do a visual inspection of the NO Do a leak check of the IDG YES Repair or replace the defective
IDG oil−system level (AMM oil system (AMM TASK
components. Does the
TASK 24−12−00−210−802). 24−12−00−210−803). Is there
message go out of view?
Is the oil level found correct? any oil leak?
YES
YES
23
System normal.
24
3 Replace the IDG oil−out
Do a continuty check of the 12 temperature bulb. Remove
wiring between the IDG oil−out YES Repair wiring as necessary NO the IDG oil−out temperature
temperature bulb connector bulb (AMM TASK
(WM24−21−00). Does the
P22EZ and DCU 1 (2) 24−13−05−000−801). Install
message go out of view?
(WM24−21−00). Is there an a new IDG oil−out
open circuit? YES temperature bulb (AMM
rfi2410001_002(1).dg, ik/ds, nov11/2010
NO TASK 24−13−05−400−801).
13
System normal.
TO SHEET 2
(BLOCK 4)
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 104
Dec 10/2014
(BLOCK 3)
25
4 Do an operational test of the
applicable IDG. For the left
Do a visual inspection of the
YES IDG 1G20EZ refer to (AMM
IDG charge filter element
TASK 24−11−01−710−801).
(AMM TASK
24−12−01−210−801). For the right IDG 2G20EZ
Is corrective action required? refer to (AMM TASK
24−11−01−710−802).
NO
Repair as necessary.
26
Do an operational test of the
5
applicable IDG. For the left
Do a visual inspection of the YES IDG 1G20EZ refer to (AMM
IDG heat exchanger (AMM TASK 24−11−01−710−801).
TASK 24−12−13−210−801). Is For the right IDG 2G20EZ
corrective action required? refer to (AMM TASK
NO
24−11−01−710−802).
Repair as necessary.
6
Do a continuty check of the 27
wiring between the connector YES
Repair wiring as necessary
P10EZ of oil pressure
(WM24−21−00).
transmitter and DCU 1 (2)
(WM24−21−00).
Is there an open circuit?
NO
28
Replace the applicable IDG
1G20EZ (2G20EZ). Remove
the IDG (AMM TASK rfi2410001_005(1).dg, ik/ds, nov11/2010
24−11−01−000−801). Install
a new IDG (AMM TASK
24−11−01−400−801).
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 105
Dec 10/2014
1 11
Set the IDG disconnect Replace the applicable IDG
mechanism (AMM TASK 24− NO (1G20EZ (2G20EZ)). Refer to
11−01−710−805). Can the IDG the removal of the IDG (AMM
disconnect mechanism be set? TASK 24−11−01−000−801).
Refer to the installation of the
IDG (AMM TASK 24−11−01−
YES
400−801).
2
Do a visual check of the IDG
oil level and oil filter differential
pressure indicators (AMM
TASK 24−12−00−210−804).
3 12
Do an operational test of the If the IDG was disconnected
applicable IDG (1G20EZ set the IDG disconnect
(2G20EZ)). Refer to the YES mechanism (AMM TASK 24−
operational test of the left IDG 11−01−710−805). Fault find the
(AMM TASK 24−11−01−710− other related EICAS message.
801). Refer to the operational Refer to 24−FC DIAG
test of the right IDG (AMM Figure 101.
TASK 24−11−01−710−801).
Was any other related EICAS
message generated?
NO
rfi2410001_006.dg, ik, 09/10/01
4
System Normal.
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 106
Nov 29/2001
PREREQUISITES
CRJ200
EICAS LOGIC
GEN 1(2) OVLD ELECT PWR (AMM 24−00−00) Overload signal from the CGU
(C) EICAS (AMM 31−41−00) applied to the DCU
ENGINES ON (AMM 71−00−00)
CB’S CB1−Q10 (CB1−Q11)
1
ON the ELECTRICAL POWER
SERVICES panel, set the GEN 11
1 (S1XA) (GEN 2 (S6XA))
Replace the applicable GCU
switch to OFF/RESET, and NO
(1A1XA (2A1XA)). Refer to the
then to ON. On the selected
removal of the GCU (AMM
generator, put a load equivalent
TASK 24−11−07−000−801).
to when the fault was reported. 1
Refer to the installation of the
On the AC ELECTRICAL
GCU (AMM TASK 24−11−07−
synoptic page, does the
400−801).
selected generator load show
more than 40 kVA?
YES
2
Do an operational test of the
applicable IDG. For the left IDG
(1G20EZ) refer to (AMM TASK
24−11−01−710−801). For the
right IDG (2G20EZ) refer to
(AMM TASK 24−11−01−710−
802). Repair as necessary.
NOTE
1 The equivalent load must be between 34 kVA
and 36 kVA for at least 2 minutes in order to generate
the GEN 1 (2) OVLD caution message.
MASTER
EFFECTIVITY: See Pageblock 24−10−00 page 101
24−10−00 Page 107
Nov 29/2001