You are on page 1of 2

Q = k A ( – dT/dx ) where:

Q dx = – k A dT Q = Heat flow, Watt constant @ SSSF


A = Exposed Area, m2
Q ʃ dx = – k A ʃ dT dT = T1 – T2 = Temperature Difference, C or K
Δx = (x2 – x1) = thickness, m
Q Δx = – k A ΔT
dT/dX = negative (decreasing T with increasing X), K/m

Q = – k A (T2 – T1) k = thermal conductivity, W/m K constant for given


( x2 – x 1 ) material (refer to table)

Electrical Circuit Analogy

ΔT = E voltage
Q = I current
RT = R resistance

From Ohm’s Law,

E = IR
ΔT = Q RT
Q = ΔT / RT

Q = (T1 – T2) / RT per unit area, m2

Q = A (T1 – T2) / RT Watt


where:

2
RT = thermal resistance, m K/W
(refer to tabulated data)
MULTI-LAYER PLANE WALL

Q = kA A (T1 – T2)/x12
Q = kB A (T2 – T3)/ x23

(T1 – T2) = Q x12/ kA A


+ (T2 – T3) = Q x23/ kB A

(T1 – T3) = (Q/A) (x12/ kA + x23/ kB )

Q = A (T1 – T3)
(x12/ kA + x23/ kB)

Electrical Analogy

Q = A (T1 – T3) / RT Watt

RT = RA + RB m2 K/W